f50_f60

68
PRODUCT CATALOGUE F 50 / F 60 Curtain-Wall With A System S 70 Windows German Engineered-Systems

description

f50_f60

Transcript of f50_f60

Page 1: f50_f60

P R O D U C T C ATA L O G U E

PR

OD

UC

T C

AT

AL

OG

UE

H E R M A N N G U T M A N N W E R K E AG • N u e r n b e rg e r S t r. 57- 81 • 91781 We i s s e n b u rg • G e r m a n y

Ph o n e : + 49 ( 0 ) 9141 / 992 - 0 • Fa x : + 49 ( 0 ) 9141 / 992 -212 • e m a i l : i n f o @ g u t m a n n . d e • w w w. g u t m a n n . d e

GU

TM

AN

N

F5

0/F

60

/ S

70

F 50 / F 60 C u r t a i n - W a l l W i t h A S y s t e m

W i n d o w sS 70

F 50 / F 60 C u r t a i n - W a l l W i t h A S y s t e m

S 70 W i n d o w s

G e r m a n E n g i n e e r e d - S y s t e m s

1/1

50

0/1

0.0

5/D

AN

/79

01

9

Page 2: f50_f60
Page 3: f50_f60

3

F50/F60

Table of contents

Introduction 04 - 05

References 06

System F 50 07 - 38

System F 60 39 - 55

System S 70 Windows 56 - 66

The catalogue shows a digest only out of the complete product program!

Page 4: f50_f60

4

A Bold Idea Turns Into Elegance

Today, largescale aluminium- and glass construction is highly appreciated. The demands on curtain-wall design are

correspondingly high. The GUTMANN curtain-Wall System F50/F60 fulfils all the requirements of modern architecture.

Whether vertical or sloped, single or multi-storey – aluminium-glass curtain-walls of graceful appearance

can be designed for high-rise buildings, according to the test certificate of ”ift” Rosenheim.

The floor plan can be straight or polygonal; the GUTMANN Curtain-Wall System F50/F60 is also suitable for

manufacturing of skylights, pyramids, domes and winter gardens.

In troduc t ion

Besides the illumination of the

working and living environment,

outer environmental influences are

shielded.

The GUTMANN F50/F60

curtain-Wall System is assigned to

Framework-Material Group 1 and

2.1, respectively, as per DIN 4108.

The design principle is convincingly

simple: Everything is the same!

Matching mullion and transom

cross-sections support an efficient

manufacturing process.

This ultimately reduces production

costs considerably.

The elimination of the need for

additional milling or attachments

at mullions and transoms

underlines the economy of design

additionally. Furthermore, the

homogeneity minimises cutting

waste and optimises warehouse

management.

Page 5: f50_f60

5

In troduc t ion

HERMANN GUTMANN WERKE AG – The Right Choice for You!

Hermann Gutmann Werke AG, with its headquarters in Weissenburg/Bavaria, has been successful in the marketpla-

ce for more than sixty years and is known both nationally and internationally for its versatile system and industry

profiles. The Gutmann Group, with roughly 950 employees, focuses on the manufacturing and selling of aluminium

frames for windows, curtain-walls and facades, aluminium system profiles, aluminium industry profiles, aluminium

wire as well as aluminium composite panels for signs, outdoor advertising and display room construction.

The products manufactured by the Gutmann Group are mainly used in the construction industry and by architects

but also in the packaging, furniture, and automobile industries, machinery and electrical branches, advertising, con-

trolling/supervision systems, and interior design.

Thanks to its commitment to innovative research and development, Hermann Gutmann Werke AG is continuously

improving its performance and product quality.

Page 6: f50_f60

6

Page 7: f50_f60

7reduced sca le

F50/F60 Sys tem F50

The Mullion-Transom Curtain Wall

Page 8: f50_f60

8 reduced sca le

F50/F60 Sys tem F50

Design Description

Page 9: f50_f60

9reduced sca le

F50/F60 Sys tem F50

Detail of Mullion-Transom Joint Assembly

Page 10: f50_f60

10 reduced sca le

F50/F60 Sys tem F50

Basic Principle of Drainage Waterremoval

Page 11: f50_f60

11reduced sca le

F50/F60 Sys tem F50

Inserts in the Mullion Profiles from Commercially AvailableCross-Sections (See Single Profiles)

Page 12: f50_f60

12 reduced sca le

F50/F60 Sys tem F50

Profiles

The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.

Page 13: f50_f60

13reduced sca le

F50/F60 Sys tem F50

Profiles

The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.

Page 14: f50_f60

14 reduced sca le

F50/F60 Sys tem F50

Profiles

The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.

Page 15: f50_f60

15reduced sca le

F50/F60 Sys tem F50

Profiles

The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.

Page 16: f50_f60

16 reduced sca le

F50/F60 Sys tem F50

Profiles

The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.

Page 17: f50_f60

17reduced sca le

F50/F60 Sys tem F50

Profiles

The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.

Page 18: f50_f60

18 reduced sca le

F50/F60 Sys tem F50

Standard Cross-Section Points

Page 19: f50_f60

19reduced sca le

F50/F60 Sys tem F50

Cross-Section Points: Mullions

Page 20: f50_f60

20 reduced sca le

F50/F60 Sys tem F50

Cross-Section Points, Assembly Mullions

Page 21: f50_f60

21reduced sca le

F50/F60 Sys tem F50

Cross-Section Point, Corner Mullion

Page 22: f50_f60

22 reduced sca le

F50/F60 Sys tem F50

Cross-Section Point, Transom

Page 23: f50_f60

23reduced sca le

F50/F60 Sys tem F50

Cross-Section Point, Outer CornerVariable 0 - 10°

Page 24: f50_f60

24 reduced sca le

F50/F60 Sys tem F50

Cross-Section Point, Outer CornerVariable 10 - 30°

Page 25: f50_f60

25reduced sca le

F50/F60 Sys tem F50

Cross-Section Point, Outer CornerVariable on One Side 10 - 30°

Page 26: f50_f60

26 reduced sca le

F50/F60 Sys tem F50

Cross-Section Points, Inner CornerVariable 0 - 10°

Page 27: f50_f60

27reduced sca le

F50/F60 Sys tem F50

Cross-Section Points, Inner CornerVariable 15 - 30°

Page 28: f50_f60

28 reduced sca le

F50/F60 Sys tem F50

Cross-Section Points, MullionStructural Curtain Wall

Page 29: f50_f60

29reduced sca le

F50/F60 Sys tem F50

Cross-Section Points, EaveVariable Eave Point 10 - 50°, with Gutter

Page 30: f50_f60

30 reduced sca le

F50/F60 Sys tem F50

Cross-Section Point, TransomInclined Glazing

Page 31: f50_f60

31reduced sca le

F50/F60 Sys tem F50

Cross-Section Points, TransomRoof-Ridge Connection

Page 32: f50_f60

32 reduced sca le

F50/F60 Sys tem F50

Assembly Example: Base Point

Page 33: f50_f60

33reduced sca le

F50/F60 Sys tem F50

Assembly Example: Ceiling Attachment

Page 34: f50_f60

34 reduced sca le

F50/F60 Sys tem F50

Semi SG - Curtain Wall

Page 35: f50_f60

35reduced sca le

F50/F60 Sys tem F50

Optical SG - Curtain Wall

Page 36: f50_f60

36 reduced sca le

F50/F60 Sys tem F50

Optical SG - Curtain Wall

Page 37: f50_f60

37reduced sca le

F50/F60 Sys tem F50

Infosection Points of Steel/Wood - Construction

Page 38: f50_f60

38 reduced sca le

F50/F60 Sys tem F50

Cross-Section Points on Wooden Structure

Page 39: f50_f60

39reduced sca le

F50/F60 Sys tem F60

The Mullion-Transom Curtain Wall

Page 40: f50_f60

40 reduced sca le

F50/F60 Sys tem F60

Design Description

Page 41: f50_f60

41reduced sca le

F50/F60 Sys tem F60

Detail of Mullion-Transom-Joint Assembly

Page 42: f50_f60

42 reduced sca le

F50/F60 Sys tem F60

Basic Principle of Drainage Water Removal

Page 43: f50_f60

43reduced sca le

F50/F60 Sys tem F60

Insert into Mullion Profiles, from Standard Cross-Sections (See Single Profiles)

Page 44: f50_f60

44 reduced sca le

F50/F60 Sys tem F60

Profiles

The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.

Page 45: f50_f60

45reduced sca le

F50/F60 Sys tem F60

Profiles

The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.

Page 46: f50_f60

46 reduced sca le

F50/F60 Sys tem F60

Profiles

The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.

Page 47: f50_f60

47reduced sca le

F50/F60 Sys tem F60

Profiles

The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.

Page 48: f50_f60

48 reduced sca le

F50/F60 Sys tem F60

Standard Cross-Section Points

Page 49: f50_f60

49reduced sca le

F50/F60 Sys tem F60

Cross-Section Points: Mullions

Page 50: f50_f60

50 reduced sca le

F50/F60 Sys tem F60

Cross-Section Points, Assembly Mullions

Page 51: f50_f60

51reduced sca le

F50/F60 Sys tem F60

Cross-Section Point, Corner Mullion

Page 52: f50_f60

52 reduced sca le

F50/F60 Sys tem F60

Cross-Section Point, Transom

Page 53: f50_f60

53reduced sca le

F50/F60 Sys tem F60

Cross-Section Point, Outer CornerVariable 0 - 10°

Page 54: f50_f60

54 reduced sca le

F50/F60 Sys tem F60

Cross-Section Points with Base Profil on Steel or Wooden Structure

Page 55: f50_f60

55reduced sca le

F50/F60 Sys tem F60

Cross-Section Points with Base Profil on Steel or Wooden Structure

Page 56: f50_f60

56 reduced sca le

S70 Sys tem S70 Window

Standard Cross-Section Points

Page 57: f50_f60

57reduced sca le

S70 Sys tem S70 Window

Standard Detail Panel Window

Page 58: f50_f60

58 reduced sca le

S70 Sys tem S70 Window

Standard Detail Panel Window

Page 59: f50_f60

59reduced sca le

S70 Sys tem S70 Window

Standard Detail Panel Window

Elektronic drive230 V ACArt.-Nr. 64710901

Page 60: f50_f60

60 reduced sca le

S70 Sys tem S70 Window

Consealed Window

Page 61: f50_f60

S70 Sys tem S70 Window

61reduced sca le

Consealed Window - Exportversion

Page 62: f50_f60

62 reduced sca le

S70 Sys tem S70 Window

Consealed Window

Page 63: f50_f60

63reduced sca le

S70 Sys tem S70 Window

Cross-Section Point: Dormer Window Upper

Page 64: f50_f60

64 reduced sca le

S70 Sys tem S70 Window

Cross-Section Point: Dormer Window Lower

Page 65: f50_f60

65reduced sca le

S70 Sys tem S70 Window

Main Door Opening Inside

Page 66: f50_f60

66 reduced sca le

Sys tem S70 WindowS70

Cross-Section Point: Wood-Aluminium Panel Window

Page 67: f50_f60
Page 68: f50_f60

P R O D U C T C ATA L O G U E

PR

OD

UC

T C

AT

AL

OG

UE

H E R M A N N G U T M A N N W E R K E AG • N u e r n b e rg e r S t r. 57- 81 • 91781 We i s s e n b u rg • G e r m a n y

Ph o n e : + 49 ( 0 ) 9141 / 992 - 0 • Fa x : + 49 ( 0 ) 9141 / 992 -212 • e m a i l : i n f o @ g u t m a n n . d e • w w w. g u t m a n n . d e

GU

TM

AN

N

F5

0/F

60

/ S

70

F 50 / F 60 C u r t a i n - W a l l W i t h A S y s t e m

W i n d o w sS 70

F 50 / F 60 C u r t a i n - W a l l W i t h A S y s t e m

S 70 W i n d o w s

G e r m a n E n g i n e e r e d - S y s t e m s

1/1

50

0/1

0.0

5/D

AN

/79

01

9