F3 Ultrasonic Flowmeter For Small Pipe Size Series...2020/08/26 · Shenzhen CHINA Tel:...
Transcript of F3 Ultrasonic Flowmeter For Small Pipe Size Series...2020/08/26 · Shenzhen CHINA Tel:...
12/F, Block A5. Nanshan Ipark, No.1001 College Rd.Nanshan District. Shenzhen CHINATel: 86-755-26745561Fax: 86-755-26745333E-mail: [email protected]
Gentos Measurement & Control Co., Ltd.
F3 Ultrasonic Flowmeter For Smal l Pipe Size Ser ies
1 page
About F3
Main characters:RS-485
4-20mA LCD
F3 Ultrasonic Flowmeter For Smal l Pipe Size Ser ies
F3 ultrasonic flowmeter is designed for catering to the small pipe size of PVC, carbon steel, stainless steel, copper which can be widely used in HVAC chilled water system, building automation system, farming irrigation system, residential water supply system, cleaning system, recirculating aquaculture system(RAS), etc. It is very easy to install, the installation only needs 30s at fast. The compact structure, is suitable for various narrow working environments.
The product is an integrated structure design, which is easy to install through four screws, andhas special insulation on the outside. The jacket reduces the hassle of field installation. It isunnecessary to cut the pipe, stop flow for installation and there is no pressure loss. F3 also hasrich network functions, supporting Wi-Fi, 4-20mA output, etc, with Cloud data storage andanalysis management system. You can have access to "Gentos iCloud", or customize the versionthat connects to your own cloud system/intelligent management system, realized unattendedand unified administration.
2 page
30 60 90 120 150 210 240 27 0 300
2
0
4
6
8
10
12
14x10 x1
Flow 0.5360 m3/h Vel 0.0136 m/s
Curve 2014-02-18 12:01:00
TCT Technology
Installation Steps
1.Take out the product 2.Clamp the pipe 3.Tighten the screw 4.Power on to start
F3 Ultrasonic Flowmeter For Smal l Pipe Size Ser ies
When the ultrasonic signal is transmitted and received through the moving liquid, there will be a difference between the upstream and downstream transit time, which can be used to calculate flow and velocity.
The TCT (Time Comb Technology) is a kind of technology used to measure signal flight time.The technology is invented by Gentos Measurement & Control Co., Ltd. in 2019. Since thetechnology was invented, it has achieved the time measurement accuracy of 50ps (TVT is130ps), and has outstanding characteristics of high accuracy, high stability and low cost.
The F3 clip on meter is measured with an integrated design. The installation is very simple. F3 is directly clipped on the pipe section, and tightened the screw to turn on the power flow measurement.
3 page
W W1
21~25
L Weight(kg)Model Ø
DN20
DN25
DN32
DN40
DN50
DN65
DN80
25~29
28~3232~36
35~3939~43
46~5050~54
59~6363~67
72-7676~80
83~8787~91
1150.04~6
0.05~9
0.09~15
0.13~23
0.20~35
0.35~60
0.55~90
1.1
0.68
0.71
0.82
0.96
1.6
2.0
Flow Rangem³/h
Dimensions Unit:mm Pipe material(PVC, Carbon Steel, Stainless Steel)
6060606060606060606060606060
105105105105105105105105105105105105105105
L1 H
115115115115115115115115115115115115115
51515656636374748989
102102113113
121121128128135135146146159159172172183183
F3 Ultrasonic Flowmeter For Smal l Pipe Size Ser ies
Temperature
Humidity
Physical specifications
Transmitter:14℉~122℉(-10℃~50℃)Transducer measurement medium:32℉~140℉(0℃~60℃)
Up to 99% RH,non-condensing
Keyboard 3 touch KeysDisplay
PC/ABSTransmitter
Protection Rate Ip54
Cable Lenght Power cable: standard lenght 2m
Performance specificationsFlow range
Accuracy
Pipe size
Fluid
Pipe material
Outputs
Power supply
Communication interface
±0.098ft/s ~ ±16ft/s (±0.03m/s ~ ±5m/s)
±2.0%
DN20 DN25 DN32 DN40 DN50 DN65 DN80
Function specificationsAnalog output:4~20mA, max load 750Ω.
10~36VDC/500mA
WIFI(standard), TTF/RS485(optional), Cannot be used at the same tine;Support FUJI protocol and MODBUS protocol
1.44'' LCD
Water
PVC, Carbon Steel, Stainless Steel, Copper
4 page
F3 Ultrasonic Flowmeter For Smal l Pipe Size Ser ies
Building Energy Saving
W W1 L Weight(kg)Model Ø Flow Rangem³/hL1 H
21~25DN20
DN25
DN32
DN40
DN50
DN65
DN80
25~29
21~2525~29
28~3232~36
35~3939~43
46~5050~54
59~6363~67
72~7676~80
1150.04~6
0.05~9
0.09~15
0.13~23
0.20~35
0.35~60
0.55~90
1.1
0.68
0.71
0.82
0.96
1.6
2.0
6060606060606060606060606060
105105105105105105105105105105105105105105
115115115115115115115115115115115115115
51515656636374748989
102102113113
Dimensions Unit:mm Pipe material(Copper)
121121128128135135146146159159172172183183
Building Automation System
HVAC
Residential water supplyFariming Irrigation
Cleaning system Recirculating Aquaculture System
ApplicationsIt can be widely used in HVAC system, building automation system, farming irrigation system, residential water supply system, cleaning system, recirculating aquaculture system(RAS), etc.
Unit
TimeSignal
Menu Wifi
Flow rate
Ftotal
Value
5 page
F3 Ultrasonic Flowmeter For Smal l Pipe Size Ser ies
Clamp-on type ultrasonic flow meter is for the difficulty of installing a conventional model in an old building. It features with clamp-on measurement, no need to cut pipes and to shut down machines. Easy operation menu Displaying Instantaneous Flow and Selecting Flow Units Optional unit, m3/h, l/m, gpm(UK), cfm, gpm(USA)
6 page
F3 Ultrasonic Flowmeter For Smal l Pipe Size Ser ies
Gentos icloud data storage and analysis Management functions. Data collection can meet different working conditions. Scan the QR code and experience the system!
Experience Account ID: gentos Password: gentos0755
Ordering Information
F3
Description
Digital Correlation Transit Time FlowmeterInstallation method: Clamp-onFlow Range: ±0.098ft/s ~ ±16ft/s (±0.03m/s ~ ±5m/s)Accuracy: ±2.0% (±1.6ft/s~±16ft/s) (±0.5m/s~±5m/s)Pipe Size Range: DN20 DN25 DN32 DN40 DN50 DN65 DN80Keyboard:3 touch KeysDisplay: 1.44" LCDPower supply: 10~36VDC/500mAProtection Rate: IP54Output: WIFI,4~20mADC, OCT pulse output, relay outputCommunication: RS-485 terminal Modbus Protocol
1
1
2WIFI(Standard)4-20mA(optional)
Output
CP
Transmitter enclosure area classificationIp54, PC/ABS enclosure
Type of transducersClamp on transducer, Operating temperature:32℉~140℉(0℃~60℃)
07
Transducer Cable LengthStandard 7ft (2m)
34
RS-485(optional)TTL(optional)
Standard Model: F3-1-1-CP-07-DN(pipe size)Description: Standard enclosure with Clamp-on transducers, WIFI, 2m cable.
DN
Pipe SizeDN20 DN25 DN32 DN40 DN50 DN65 DN80
12/F, Block A5. Nanshan Ipark, No.1001 College Rd.Nanshan District. Shenzhen CHINATel: 86-755-26745561Fax: 86-755-26745333E-mail: [email protected]
Gentos Measurement & Control Co., Ltd.
Find our website with Google search: www.pflow.com.cn