nion control i/o
25 pin GPIO connector
Serial control port
Serial bridgingvia CobraNet(RS-485)
Ethernet jack
GPIO Dialog BoxesNioNode CAB 4n
Not a selection in Properties, always available on GPIO
Tab
nion GPIO
Up to 16 User ConfigurableLow Voltage/Current GIO
AS..–16 Digital Input Or Output• 0.8 - 2.0VDC TTL Input• 3.3VDC TTL Output•Up To 8 Rotary Encoders
nion GPIO
Up to 16 User ConfigurableLow Voltage/Current GIO
AS..–16 Analog Input• 0 - 24VDC input with 12 Bit Precision• 1k Or 10K Potentiometer
External Or Self Powered (to ground)
nion GPIO
Up to 16 User ConfigurableLow Voltage/Current GIO
AS..• Three Clock Outputs On Select GIO
•One each–Word/Brick/Frame Clock
nion GPIO
PLUSFour High Current Outputs
500mA @ 11.5VDCConfigurable as PWM
AND
ONE SPDT Fault Relay
cab4n GPIO
8 Analog Or Digital I/O4 SPDT Relays1 SPDT Fault Relay
GPIO-25
• DB-25 to Euro-Connectors Break Out• 4” DIN Rail• 3’ Cable
Driving An LED With A Digital Output+12VDC
GPIO Digital Output
1k 1/4W
General Purpose NPN
TransistorGain ≈ 100
Series Resistance As Needed To Protect Transistor & LED
This diagram is for general reference only and should not be used in system design.
Driving A Relay Coil With GPIO
GPIO Digital Output
1k 1/4W
Series Resistance As Needed To Protect Transistor
+12VDC
1N400312 VDC
Relay CoilImax
<100mA
ALWAYS Use A Flyback Diode On A Relay Coil!It Prevents Back EMF From Destroying The Switching Transistor.
General Purpose NPN
TransistorGain ≈ 100
This diagram is for general reference only and should not be used in system design.
Serial Control• Control Protocols
– RS422, RS485, RS232– Standard ASCII Text Strings
• PASHA, X-Net AND RATC2• Control Alias
– Replaces Control Groups– Improved User Interface– Supports Long Alias Names
•Case Sensitive•No Spaces Allowed
PASHA And X-Net Still Use Three Character Alias
Nion Serial Control Port
•DB9 on the rear of the unit.•Unique pinout - be careful.•RS422/485 operation.•Integral 120 ohm terminators.•Use pins 1 & 2 for RS485 (1+, 2-).•Supplies +12VDC @ 500mA
for XControls.
Control Via TCP/IP
•RATC And RATC2–Both Supported–Re-Use Existing Control Systems–RATC Type Must Be Selected During Design (NioNode Properties)
–RATC2 - Improved User Interface•Shorter Commands•Type “h” For Command List
RATC2 Telnet Session
Control Via TCP/IP
NWare Kiosk
NWare Kiosk
CONtrol MANager
•SNMP Functions (Currently not factory
supported)
•Offload Control Duties From NIONs
•Control Third Party Products (Currently not factory supported)