Experimental validation of a fully covered photovoltaic ... · system. It was found that partially...

12
Full Length Article Experimental validation of a fully covered photovoltaic thermal compound parabolic concentrator system Deepali Atheaya a,, Arvind Tiwari b , G.N. Tiwari a a Centre for Energy Studies, Indian Institute of Technology, Delhi, Hauz Khas, New Delhi 11 00 16, India b Department of Electrical Engineering, College of Engineering, Qassim University, P.O. Box-6677, Buraydah 51452, Saudi Arabia article info Article history: Received 19 January 2016 Revised 28 June 2016 Accepted 28 June 2016 Available online 9 July 2016 Keywords: Photovoltaic thermal Thermal modeling Instantaneous thermal efficiency abstract The main advantage of PVT-CPC system is to generate both thermal and electrical energy at a low cost. Hence, an analytical expression of electrical and thermal efficiency of fully covered photovoltaic thermal compound parabolic concentrator (PVT-CPC) system has been derived as a function of climatic and design parameters. Further, an experiment has been performed for a typical day during the summer month namely 3rd and 4th May, 2016 at IIT, Delhi (India) for [case (A)] conventional CPC system and [case (B)] fully covered PVT-CPC system for thermal validation. The theoretical and experimental results for the outlet fluid temperature and electrical efficiency were verified with correlation coefficient (r) of 0.99. This indicates a close agreement between the theoretical and experimental results for thermal and electrical energy. Ó 2016 Karabuk University. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). 1. Introduction Today there is an energy demand wor ldwide and researchers are trying to get a viable solution for the undergoing energy crisis. Solar energy has been utilized to get clean energy [1,2]. Photo- voltaic thermal (PVT) technologies can be one of solutions to meet the energy shortage effectively [3]. PVT module is used to generate electrical and thermal energy for space heating, residential and industrial applications. Rabl [4] firstly designed a trough shaped cylindrical collector for concentrating solar intensity to obtain high temperatures. A photovoltaic thermal (PVT) collector was explored theoretically and tested by Gibart [5] by using a concentrated solar radiation. The results showed better thermal and electrical perfor- mance of the collector as compared to conventional flat thermal collector. Based on solar trough concentration, an experiment of a two phase photovoltaic thermal collector was conducted by Tan et al. [6]. The results indicated that as the temperature of solar cell attained 73 °C, the working medium output temperature was raised by 12.06 °C. An asymmetric compound parabolic photo- voltaic concentrator (ACPPVC) was designed, fabricated and tested in the outside environment with and without concentrators by Mallick et al. [7]. It was observed that ACPPVC produced 1.62 times more power in comparison with conventional concentrator. A small concentrating photovoltaic and thermal system was ana- lyzed by Kribus et al. [8]. This system concentrated solar energy about 500 times. Kong et al. [9] designed a similar concentrated photovoltaic thermal system to achieve a uniformly concentrated radiation. A thermal analysis of high concentration thermal system was also carried out by Chen et al. [10]. It was observed that for high concentration ratio and mass flow rate, the electrical effi- ciency increases with decrease in thermal efficiency. Xu et al. [11] studied experimentally a solar PV thermal system with per- manent truncated parabolic concentrators. In their system, a refrigerant R134a flowed in the aluminum tubes below the PV cells to extract the solar radiation for evaporation of refrigerant. Further, the refrigerant was condensed to heat water in a condenser. A flux concentrating rate of fixed parabolic concentrator was reported as 1.6 times more power output as compared to PV cells without con- centrator. Kunnemeyer et al. [12] investigated the performance of a V-trough photovoltaic thermal concentrator and reported that by concentrating solar intensity on the PV cells and cooling them, bet- ter electrical output can be achieved. A design of an air gap lens walled compound parabolic concentrator photovoltaic thermal (ALCPC-PVT) system was proposed and tested by Li et al. [13]. An improved overall system efficiency of 65.5% was reported by them. Mohsenzadeh and Hosseini [14] studied and tested a photovoltaic thermal system integrated with reflectors and vacuum tube solar http://dx.doi.org/10.1016/j.jestch.2016.06.014 2215-0986/Ó 2016 Karabuk University. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Abbreviations: CPC, compound parabolic concentrator; PVT, photovoltaic thermal. Corresponding author. E-mail address: [email protected] (D. Atheaya). Peer review under responsibility of Karabuk University. Engineering Science and Technology, an International Journal 19 (2016) 1845–1856 Contents lists available at ScienceDirect Engineering Science and Technology, an International Journal journal homepage: www.elsevier.com/locate/jestch

Transcript of Experimental validation of a fully covered photovoltaic ... · system. It was found that partially...

Page 1: Experimental validation of a fully covered photovoltaic ... · system. It was found that partially covered PVT-CPC system has a superior thermal performance than fully covered PVT-CPC

Engineering Science and Technology, an International Journal 19 (2016) 1845–1856

Contents lists available at ScienceDirect

Engineering Science and Technology,an International Journal

journal homepage: www.elsevier .com/ locate / jestch

Full Length Article

Experimental validation of a fully covered photovoltaic thermalcompound parabolic concentrator system

http://dx.doi.org/10.1016/j.jestch.2016.06.0142215-0986/� 2016 Karabuk University. Publishing services by Elsevier B.V.This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

Abbreviations: CPC, compound parabolic concentrator; PVT, photovoltaicthermal.⇑ Corresponding author.

E-mail address: [email protected] (D. Atheaya).

Peer review under responsibility of Karabuk University.

Deepali Atheaya a,⇑, Arvind Tiwari b, G.N. Tiwari a

aCentre for Energy Studies, Indian Institute of Technology, Delhi, Hauz Khas, New Delhi 11 00 16, IndiabDepartment of Electrical Engineering, College of Engineering, Qassim University, P.O. Box-6677, Buraydah 51452, Saudi Arabia

a r t i c l e i n f o a b s t r a c t

Article history:Received 19 January 2016Revised 28 June 2016Accepted 28 June 2016Available online 9 July 2016

Keywords:Photovoltaic thermalThermal modelingInstantaneous thermal efficiency

The main advantage of PVT-CPC system is to generate both thermal and electrical energy at a low cost.Hence, an analytical expression of electrical and thermal efficiency of fully covered photovoltaic thermalcompound parabolic concentrator (PVT-CPC) system has been derived as a function of climatic and designparameters. Further, an experiment has been performed for a typical day during the summer monthnamely 3rd and 4th May, 2016 at IIT, Delhi (India) for [case (A)] conventional CPC system and [case(B)] fully covered PVT-CPC system for thermal validation. The theoretical and experimental results forthe outlet fluid temperature and electrical efficiency were verified with correlation coefficient (r) of0.99. This indicates a close agreement between the theoretical and experimental results for thermaland electrical energy.� 2016 Karabuk University. Publishing services by Elsevier B.V. This is an open access article under the CC

BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

1. Introduction

Today there is an energy demand wor ldwide and researchersare trying to get a viable solution for the undergoing energy crisis.Solar energy has been utilized to get clean energy [1,2]. Photo-voltaic thermal (PVT) technologies can be one of solutions to meetthe energy shortage effectively [3]. PVT module is used to generateelectrical and thermal energy for space heating, residential andindustrial applications. Rabl [4] firstly designed a trough shapedcylindrical collector for concentrating solar intensity to obtain hightemperatures. A photovoltaic thermal (PVT) collector was exploredtheoretically and tested by Gibart [5] by using a concentrated solarradiation. The results showed better thermal and electrical perfor-mance of the collector as compared to conventional flat thermalcollector. Based on solar trough concentration, an experiment ofa two phase photovoltaic thermal collector was conducted byTan et al. [6]. The results indicated that as the temperature of solarcell attained 73 �C, the working medium output temperature wasraised by 12.06 �C. An asymmetric compound parabolic photo-voltaic concentrator (ACPPVC) was designed, fabricated and testedin the outside environment with and without concentrators by

Mallick et al. [7]. It was observed that ACPPVC produced 1.62 timesmore power in comparison with conventional concentrator. Asmall concentrating photovoltaic and thermal system was ana-lyzed by Kribus et al. [8]. This system concentrated solar energyabout 500 times. Kong et al. [9] designed a similar concentratedphotovoltaic thermal system to achieve a uniformly concentratedradiation. A thermal analysis of high concentration thermal systemwas also carried out by Chen et al. [10]. It was observed that forhigh concentration ratio and mass flow rate, the electrical effi-ciency increases with decrease in thermal efficiency. Xu et al.[11] studied experimentally a solar PV thermal system with per-manent truncated parabolic concentrators. In their system, arefrigerant R134a flowed in the aluminum tubes below the PV cellsto extract the solar radiation for evaporation of refrigerant. Further,the refrigerant was condensed to heat water in a condenser. A fluxconcentrating rate of fixed parabolic concentrator was reported as1.6 times more power output as compared to PV cells without con-centrator. Kunnemeyer et al. [12] investigated the performance of aV-trough photovoltaic thermal concentrator and reported that byconcentrating solar intensity on the PV cells and cooling them, bet-ter electrical output can be achieved. A design of an air gap lenswalled compound parabolic concentrator photovoltaic thermal(ALCPC-PVT) system was proposed and tested by Li et al. [13]. Animproved overall system efficiency of 65.5% was reported by them.Mohsenzadeh and Hosseini [14] studied and tested a photovoltaicthermal system integrated with reflectors and vacuum tube solar

Page 2: Experimental validation of a fully covered photovoltaic ... · system. It was found that partially covered PVT-CPC system has a superior thermal performance than fully covered PVT-CPC

Nomenclature

A area (m2)Aa total aperture area (m2)Ar total receiver area (m2)b breadth of receiver (m)cf specific heat of fluid (J/kg K)bo breadth of aperture area (m)dx elemental length (m)F 0 flat plate collector efficiency factorFR flow rate factor, dimensionlessh heat transfer coefficient (W=m2 K)Lr total length of the receiver area (m)PF1 first penalty factor due to glass coverPF2 second penalty factor due to absorber/receiver platePFc penalty factor due to glass cover for the portion cov-

ered by glazingLp receiver plate thickness (m)Li insulation thickness (m)Lg glass cover thickness (m)It total radiation (W/m2)Id diffuse radiation (W/m2)Ib beam radiation (W/m2)Ut;ca overall heat transfer coefficient from solar cell to

ambient through glass cover (W/m2 K)Ut;cp overall heat transfer coefficient from solar cell to

plate (W/m2 K)Ut;pa total (top and bottom) overall heat transfer coefficient

from plate to ambient (W/m2 K)_mf mass flow rate of water in (kg/s)

UL1 overall heat transfer coefficient from blackened sur-face to ambient

ðW=m2KÞgo efficiency at standard test condition (It ¼ 1000 W/m2,To ¼ 25 �C)

bo temperature coefficient of efficiency (K�1)

Greek lettersa absorptivitybc packing factorq reflectivitys transmittivitygi instantaneous thermal efficiencyðasÞeff product of effective absorptivity and transmittivityg thermal efficiency

Subscripta ambientc solar celleff effectivef fluidfi inlet fluidfo outlet fluidg glassm modulep plate

1846 D. Atheaya et al. / Engineering Science and Technology, an International Journal 19 (2016) 1845–1856

water heaters. The results indicated an increase in electrical andthermal energy output of the system. Recently, a study of photo-voltaic thermal double pass and flat and compound parabolic con-centrators system (PVT-CPC) was carried out by Elsafi andGandhidasan [15] and the PVT-CPC system showed the best perfor-mance. Atheaya et al. [16] proposed a partially covered PVT-CPCsystem. It was found that partially covered PVT-CPC system has asuperior thermal performance than fully covered PVT-CPC system.Further, fully covered PVT-CPC gives better electrical power. Themain purpose of this work is to compare the performance of con-ventional compound parabolic concentrator system and fully cov-ered photovoltaic thermal compound parabolic concentratorsystem by using the characteristic equation/curve to meet the elec-trical and thermal energy demand of users. Now, the prime objec-tive of this present paper is experimental validation of the thermalmodel developed by Atheaya et al. [16].

2. Brief description of experimental set up

2.1. Conventional CPC system [case (A)]

An experimental set up of conventional CPC system wasinstalled at the roof top of the building of IIT, Delhi (28�370N77�140E). The sketch of the experimental arrangement for [case(A)] has been shown in Fig. 1. The conventional CPC system wasmounted on a mild steel frame. The absorber plate was made upof copper and it had a selective coating of black chrome platingto enhance the absorptivity of plate. A glass plate was fixed atthe top of it. A casing of aluminum material was fabricated andboth the absorber plate and the glass were fitted inside the casingto reduce thermal losses. Water is allowed to flow below the absor-ber plate in the copper tubes and its inlet and outlet pipe arrange-ment has been shown in the Fig. 2. The capacity of water tank was

30 l and it was placed on a stand and connected to the inlet of thesystem. The water flowed from water tank to the pipe and thenmoved parallel into four smaller tubes and finally gets collectedat the outlet. The reflectors of the CPC were made up of stainlesssteel polished material due to its high corrosion resistance,enhanced strength and high reflectivity. The reflectors were fittedwith the whole aluminum casing with the help of three mild steelstrips (32 mm � 5 mm) which were placed at three different placeson both reflectors for support. A floating valve was placed insidethe tank to maintain the water level at a particular height to ensureconstant mass flow rate. The copper tube in plate was insulatedfrom below by using glass wool to reduce bottom losses. Firstly,the experiment was performed at the conventional CPC systemon 3rd May, 2016 in New Delhi.

2.2. Fully covered PVT-CPC system [case (B)]

The sketch of an experimental arrangement of fully coveredPVT-CPC system has been illustrated in Fig. 3. In this case, a semi-transparent PV module (101 cm � 51 cm) was fixed to the top ofglass as shown in Fig. 4. The PV module was sealed by placing plas-tic rectangular sheets and putty sealant The Figs. 5–7 shows theactual photograph of the top view, front view and side view of fullycovered PVT-CPC system. The experiment was performed for fullycovered PVT-CPC system on 4th May, 2016 in New Delhi.

3. Thermal modeling

The assumptions for writing the energy balance equations forcases (A) and (B) are as follows:

� Both the conventional CPC and fully covered PVT-CPC systemsare considered in the quasi steady state.

Page 3: Experimental validation of a fully covered photovoltaic ... · system. It was found that partially covered PVT-CPC system has a superior thermal performance than fully covered PVT-CPC

Glass (top layer)

absorber plate (second layer)

Reflector

Reflector (Stainless

steel)

Outlet

Watertank

Inlet

arrangement of waterflowing below the plate(third layer)

Insulation (fourth layer)

Aluminum frame

Supply mains

Floatingvalve

Foundation

Mild steel (stand)

Fig. 1. Sketch of experimental arrangement of conventional CPC system.

Water inlet

Glass

Water tank

Reflectors

Mild steel stand

Absorber plate below glass

Water Outlet

Temperature indicator

Fig. 2. Photograph of experimental arrangement of conventional CPC system.

D. Atheaya et al. / Engineering Science and Technology, an International Journal 19 (2016) 1845–1856 1847

� For both systems, the ohmic losses are neglected.� For both systems, there is no temperature gradient across thick-ness of PV module and glass material.

� The heat capacity of glass and PV module are neglected.� Heat conduction is one dimensional.

3.1. Thermal modeling of conventional CPC system, [case (A)]

Following Atheaya et al. [16], the energy balance equationshave been written as follows:

(i) Receiver

qapsgIbAa ¼ F 0hpf ðTp � Tf ÞAr þ Ut;paðTp � TaÞAr ð1Þ(ii) Flowing fluid

_mf cfdTf

dxdx ¼ F 0hpf ðTp � Tf Þbdx ð2Þ

Eqs. (1) and (2) can be solved with initial condition Tf ¼ T 0fi at

x ¼ 0 as follows:

Tf ¼PFcðasÞc;eff Ib

Ul;cþ Ta

� �1� exp

�F 0Ul;cbx_mf cf

� �� �

þ T 0fi exp

�F 0Ul;cbx_mf cf

� �ð3Þ

Page 4: Experimental validation of a fully covered photovoltaic ... · system. It was found that partially covered PVT-CPC system has a superior thermal performance than fully covered PVT-CPC

PV module (top layer)

glass(second layer)

Reflector

insulation (fourth layer)

Reflector (Stainless

steel)

OutletInlet

arrangement of waterflowing below the plate(third layer)

Aluminum frame

Foundation

Mild steel (stand)

WatertankSupplymains

Floatingvalve

Fig. 3. Sketch of an experimental arrangement of fully covered PVT-CPC system.

Insulation

Copper tubes

Clamps

Absorber plate(Copper)

PV module

Glass

Aluminum frame

Reflector Stainless steel(polished)

Air gap

Fig. 4. Front view sketch of fully covered PVT-CPC system.

1848 D. Atheaya et al. / Engineering Science and Technology, an International Journal 19 (2016) 1845–1856

The outlet water temperature of conventional CPC system(Tf ¼ Tfo1 at x ¼ Lr) can be evaluated as follows:

Tfo1 ¼ PFcðasÞc;eff IbUl;c

þ Ta

� �1� exp

�F 0Ul;cb� Lr_mf cf

� �� �

þ T 0fi exp

�F 0Ul;cb� Lr_mf cf

� �ð4aÞ

Therefore, the outlet water temperature (Tfo1) at the exit of con-ventional CPC system has been calculated from

Tfo1 ¼ PFcðasÞc;eff IbUl;c

þ Ta

� �1� exp

�F 0Ul;cAr

_mf cf

� �� �

þ T 0fi exp

�F 0Ul;cAr

_mf cf

� �ð4bÞ

with (Ar ¼ b� Lr).

3.2. Thermal modeling of fully covered PVT-CPC system, [case (B)]

The energy balance equations have been written for the pro-posed system:

(i) For semi-transparent PV component

qacsgbcIbAa ¼ ½Ut;caðTc � TaÞ þ Ut;cpðTc � TpÞ�Ar þ qgmIbAa ð5Þ(ii) For blackened tube in plate type absorber

qaps3gð1� bcÞIbAa þ Ut;cpðTc � TpÞAr ¼ F 0hpf ðTp � Tf ÞAr ð6ÞIn the above expressions ‘‘bc” is the packing factor of PV module

and it is the ratio of total area of solar cells to the area of PVmodule.

(iii) For fluid flowing beneath the absorber

_mf cfdTf

dxdx ¼ F 0hpf ðTp � Tf Þbdx ð7Þ

From Eqs. (5) and (6) Tc , Tp (solar cell temperature and platetemperature) have been evaluated as follows:

Tc ¼ðasÞ1;eff Ib þ Ut;caTa þ Ut;cpTp

Ut;ca þ Ut;cpð8Þ

where ðasÞ1;eff ¼ qðaCbCsg � gmÞ AaAr

and

Tp ¼ðasÞ2;eff Ib þ PF1ðasÞ1;eff Ib þ UL1Ta þ F 0hpf Tf

F 0hpf þ UL1ð9Þ

By using Eq. (7), Eqs. (8) and (9) have been rewritten as:

_mf cfdTf

dxdx ¼ bF 0½PF2ðasÞm;eff Ib � Ul;mðTf � TaÞ�dx ð10Þ

The solution of above equation with initial conditionTf

��x¼0 ¼ Tfi, is given as follows:

Tf ¼PF2ðasÞm;eff Ib

Ul;mþ Ta

� �1� exp

�bUl;mF0x

_mf cf

� �� �

þ Tfi exp�bUl;mF

0x_mf cf

� �ð10aÞ

Thus, the average fluid temperature underneath the PV module(Tf ) by integrating above equation is given by

Tf ¼ 1Lr

Z Lr

0Tf dx ð11Þ

Page 5: Experimental validation of a fully covered photovoltaic ... · system. It was found that partially covered PVT-CPC system has a superior thermal performance than fully covered PVT-CPC

Temperature indicator

Water tank

PV module

Reflector

Inlet water

Water exit

Clamps

FoundationMild Steel Stand

Fig. 6. Photograph of front view of experimental arrangement of fully covered PVT-CPC system.

PV module Reflectors

101cm

40cm

Fig. 5. Photograph of top view of experimental arrangement of fully covered PVT-CPC system.

D. Atheaya et al. / Engineering Science and Technology, an International Journal 19 (2016) 1845–1856 1849

or,

Tf ¼PF2ðasÞm;eff Ib

Ul;m

� �1� Frm

F 0

� �þ Ta 1�

_Frm

F 0

" #þ Tfi

Frm

F 0

� �ð12Þ

where Frm ¼ _mf cfUl;mAr

1� exp �F0Ul;mAr_mf cf

n oh iBy substituting the expression for Tf from Eq. (12) in Eq. (9), one

gets an expression for Tp (average plate temperature). After obtain-ing an expression for Tp; an expression for an average solar celltemperature (Tc) can be evaluated from Eq. (8). Further, following

Evans [17] and Schott [18], the solar cell efficiency (gc) of solar cellis as follows:

gc ¼ go½1� boðTc � ToÞ� ð13Þ

For the values of Tc (Eq. (8)), the solar cell efficiency (gc) hasbeen evaluated.

Further, an analytical expression for electrical efficiency of asolar cell of PV module can be derived by substituting average solarcell temperature (Tc) expression in Eq. (13).

An analytical expression for the solar cell efficiency (gc) is givenby

Page 6: Experimental validation of a fully covered photovoltaic ... · system. It was found that partially covered PVT-CPC system has a superior thermal performance than fully covered PVT-CPC

gc ¼

go 1� bo

qðaCbCsg AaAr

� �þ Ut;cpðasÞ2;eff

F 0hpfþUL1þ Ut;cpPF1�qðaCbCsg Þ Aa

Arð ÞðF0hpfþUL1Þ

þUt;cpF 0hpf PF2

ðF 0hpfþUL1ÞUl;m� ðasÞ2;eff þ PF1 � qaCbCsg Aa

Ar

� �n oh i1� Frm

F 0

26664

37775Ib

þ Ut;ca þ Ut;cpUL1F 0hpfþUL1

þ Ut;cpF 0hpfðF 0hpfþUL1Þ 1� Frm

F 0 :h i

Ta þ Ut;cphpf FrmTfiðF 0hpfþUL1Þ

Ut;caþUt;cp

8>>>>>>>>>>>>>>>>>>><>>>>>>>>>>>>>>>>>>>:

9>>>>>>>>>>>>>>>>>>>=>>>>>>>>>>>>>>>>>>>;

� To

2666666666666666666664

3777777777777777777775

1�qsggobobc

AaArð Þ 1þ Ut;cpPF1

ðF0hpf þUL1Þþ Ut;cpF

0hpf PF2ðF0hpf þUL1ÞUl;m

1�FrmF0½ �

n oIb

Ut;caþUt;cp

ð14Þ

Reflector

Inlet water

Foundation

Mild steel frame

Fig. 7. Photograph of side view of experimental arrangement of fully covered PVT-CPC system.

1850 D. Atheaya et al. / Engineering Science and Technology, an International Journal 19 (2016) 1845–1856

Following Tiwari et al. [19], the electrical efficiency, gm of PVcomponent has been evaluated as follows:

gm ¼ sgbcgc ð15ÞThe water temperature at the outlet of fully covered PVT-CPC

system (Tf ¼ Tfo at x ¼ Lr) from Eq. (12) is as follows:

Tfo ¼PF2ðasÞm;eff Ib

Ul;mþ Ta

� �1� exp

�F 0Ul;mAr

_mf cf

� �� �

þ Tfi exp�F 0Ul;mAr

_mf cf

� �ð16Þ

4. Experimental observations

The following hourly parameters were measured during theexperiment:

i. An ambient temperature (Ta)ii. An inlet and outlet water temperature (Tfi and Tfo1)

iii. Receiver plate temperature and glass temperature (Tp and Tg)iv. Solar intensity (It, Ib and Id)v. Mass flow rate ( _mf )vi. Open circuit voltage (Voc) and short circuit current (Isc)vii. Load voltage(VL) and current(Isc).

4.1. Methodology

The conventional CPC and fully covered PVT-CPC systems withsouth facing were inclined at an angle equal to latitude (28�350N,approx 30�). The total (It) and diffuse radiations (Id) were measuredat the absorber plate. The beam radiation ðIbÞ was measured by thedifference between total radiations and diffuse radiations. All theradiations were measured by ‘‘Solarimeter” instrument. Thisinstrument was manufactured by Central Electronics Limited(CEL) Ltd., Sahibabad, U.P, India with 5% accuracy of overall radia-tion. It has a least count of 20 W/m2. Also, ambient air temperatureðTaÞ; inlet fluid temperature ðTaÞ; absorber plate temperature ðTpÞ;

Page 7: Experimental validation of a fully covered photovoltaic ... · system. It was found that partially covered PVT-CPC system has a superior thermal performance than fully covered PVT-CPC

D. Atheaya et al. / Engineering Science and Technology, an International Journal 19 (2016) 1845–1856 1851

glass temperature ðTgÞ; outlet fluid temperatures ðTfo1Þ were mea-sured by using thermometers and thermocouples. The thermocou-ples used in the experiment were copper constantanthermocouples. The zeal thermometer was used to calibrate it.The experiments were conducted at constant mass flow rates of0.10 kg/s. The observations were recorded at an interval of onehour duration. The readings were taken from 9 am to 5 pm. Theinstantaneous thermal efficiency ðgiÞ for both CPC system andPVT-CPC systems were calculated by the following expression:

gi ¼_mf cf ðTfo1 � TfiÞ

AaIbð17Þ

The power output of the photovoltaic modules were calculatedexperimentally by using the values of short circuit current (Isc) andopen circuit voltage (Voc) across the PV module. The short circuitcurrent, open circuit voltage, load current and load voltage werenoted by using the AC/DC clamp meter. The power output of thePV module of fully covered PVT-CPC system is given as:

Pm ¼ FF � Isc � Voc ð18Þwhere FF stands for fill factor which is a constant. Pm is the maxi-mum power of the PV module. The fully covered PVT-CPC systemperformance has been evaluated by calculating the thermal andelectrical efficiencies.

gi;exp;m ¼ Pm

Aa � Ibð19aÞ

By substituting Pm from Eq. (18), the instantaneous electricalefficiency has been calculated experimentally through the expres-sion given as:

gi;exp;m ¼ FF � Isc � Voc

Aa � Ibð19bÞ

where Aa is the aperture area and Ib is the beam radiation availableon the aperture surface.

5. Exergy analysis

The overall rate of exergy gain is basically the summation ofrate of thermal and electrical exergy. By using the second law ofthermodynamics, the overall rate of exergy gain in W is calculatedas:

_Ex;ov ¼ _Ex;th þ _Ex;el ð20ÞFollowing Hepbasli [20], the thermal exergy expression of the

conventional CPC system [case (A)] and fully covered PVT-CPC sys-tem [case (B)] has been given as:

_Ex;th ¼ _mf cf ðTfo � TfiÞ � ðTa þ 273Þ ln ðTfo þ 273ÞðTfi þ 273Þ

� �ð21Þ

The electrical exergy extracted by the photovoltaic module ofthe fully covered PVT-CPC system is as follows:

_Ex;el ¼ gmIbqAa ð22Þ

6. Overall thermal energy gain

The overall thermal energy gain expression from the first law ofthermodynamics is as follows:

X_Qe;ov ¼

X_Qe;th þ

P _Qe;el

nPð23Þ

‘n0P ’ is the conversion efficiency factor of thermal power plant. It liesin the range of 0.20–0.40 and its value is 0.38 for high value coal.

7. Statistical analysis

Following Chapra and Canale [21], a detailed statistical analysiswas done to match up the experimental results with the theoreti-cal calculated results. The correlation coefficient (r) has been calcu-lated as:

r ¼ nP

XiYi �P

XiP

YiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffinP

X2i �

PXið Þ2

ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffinP

Y2i �

PYið Þ2

qr ð24Þ

Xi is the theoretical value of ith number of observations, Yi is theexperimental value of ith number of observations and n is the totalnumber of noted observations.

Root mean square percent deviation (e) has been determinedfrom

ðeÞ ¼ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiP ðeiÞ2

n

sð25Þ

here,

ei ¼ Xi � Yi

Xi

� �� 100

8. Results and discussion

Fig. 8 shows the experiment readings of beam radiation (Ib) andambient temperature (Ta). The experimental readings of conven-tional CPC and fully covered PVT-CPC systems were taken on 3rdand 4th May, 2016 at an interval of an hour. It can be seen fromFig. 8 that for both systems Ib was maximum around 1 pm. More-over, the ambient temperature varies between 34–41 �C. The massflow rate for [case (A)] and [case (B)] were set as 0.01 kg/s. Theother design parameters of both the cases (A) and (B) are illus-trated in Table 1. Tables 2 and 3 specify experimental readings ofconventional CPC system and fully covered PVT-CPC systemrespectively. A program in Matlab 2010 was made to evaluatethe theoretical results. It can be noted that both the systems (con-ventional CPC and fully covered PVT-CPC systems) were exposed toalmost same solar radiation and ambient temperature. The hourlyvariation of theoretically calculated and experimental results foroutlet fluid temperatures of case (A) and (B) have been presentedin Fig. 9. From the figure it can be observed that the outlet fluidtemperature in the case of conventional CPC system lies in therange of 42–57 �C and for fully covered PVT-CPC system there isa decrease in outlet water temperature and it lies in the range of34.5–42.5 �C. The maximum temperatures rise attained by conven-tional CPC system was 16.5 �C and it was 3 �C for fully coveredPVT-CPC system. This may be due to the reason that in the caseof fully covered PVT-CPC system, the PV module has been mountedat the top of glass surface in the conventional CPC system. The PVmodule generates electrical energy. The thermal energy which istransferred to the absorber plate is the sum of indirect gain fromthe back of PV module to the plate and direct gain from the nonpacking area of the PV module. So the thermal energy in the fullycovered PVT-CPC was reduced significantly as compared to theconventional CPC system. The statistical analysis was done byusing Eqs. (24) and (25) and the results indicated the correlationcoefficient (r = 0.99) and root mean square percent deviation (e)as (e = 2.68 and, e = 2.40) respectively. The results show a goodconformity between the theoretical and the experimental results.

Fig. 10 shows hourly variation of theoretically calculated andexperimentally evaluated instantaneous electrical efficiency forfully covered PVT-CPC system. It can be seen from the Fig. 10 thatthe instantaneous electrical efficiency for fully covered PVT-CPC

Page 8: Experimental validation of a fully covered photovoltaic ... · system. It was found that partially covered PVT-CPC system has a superior thermal performance than fully covered PVT-CPC

Table 1Various design parameters of conventional CPC and fully covered PVT-CPC systems.

Parameters Values Parameters Values

Aa 1.04 m2 Ki 0.166 W/m KAr 1m2 Kp 64 W/m KLr 1.01 m Lg 0.003 mbo 1.03 m Li 0.100 mb 0.51 m Lp 0.002 mF 0 0.9680 PFc 0.9842Kg 0.816 W/m2 K hpf 100 W/m2 Khi 5.7 W/m2 K q 0.84hi1 5.8 W/m2 K q0 0.84ho 9.5 W/m2 K ac 0.9ap 0.9 Ut;pa 4.8 W/m2KUl;c 4.7 W/m2 K sg 0.95cf 4179 J/Kg K bc 0:89go 0.15 _mf 0.01 kg/s

09:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:000

10

20

30

40

50

60

70

80

90

100

09:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:000

100

200

300

400

500

600

700

800

900

1000

Bea

m ra

diat

ion

(Ib),

W/m

2

Time, hours

Ta (conventional CPC system) T

a (fully covered PVT-CPC system)

Am

bien

t tem

pera

ture

(Ta),

o C

Ib (conventional CPC system) I

b (fully covered PVT-CPC system)

Fig. 8. Hourly trend of beam radiation (Ib) and ambient temperature (Ta) when experiment was conducted for both conventional CPC system (3rd May, 2016) and fullycovered PVT-CPC system (4th May, 2016).

1852 D. Atheaya et al. / Engineering Science and Technology, an International Journal 19 (2016) 1845–1856

system decreases over the period (9:00–12:00 h), even when thesolar radiation increases during this period. With an increase insolar radiation the solar cell temperature also rises. At elevatedtemperatures, the electrical energy losses occur as there is a colli-sion of the electrons in the depletion region of a solar cell. There-fore, the electrical efficiency (gm) of a PV module reduces. Fromthe Eq. (13) it can be observed that when average solar cell temper-ature (Tc) is increased the solar cell efficiency (gc) decreases. Theexperimental instantaneous electrical efficiency (ɳm) was calcu-

Table 2Hourly variation of Ta, Tfi, Tfo1, It, Id, Ib for fully covered PVT-CPC system for a typical day (

S. no. Time (hr) Ta (�C) Tfi (�C) Tp (�C) Tfo (�C) It (W/m

1 9:00 34 33.5 38 34.5 610.902 10:00 35 34.5 44.1 37 775.603 11:00 36.5 36.0 49.2 38 890.504 12:00 39 38.5 50.9 40.0 949.005 13:00 40.5 40.0 53.7 42.5 950.006 14:00 41 40.5 54 42.5 887.537 15:00 39 39 54.2 42 762.008 16:00 38.5 39 54.9 40.5 582.109 17:00 38 38 53.1 40 371.00

lated by the help of Eq. (19b). It was observed that the instanta-neous electrical efficiency values have been in the range of 6–10% as well as theoretical trend has been followed in a similarmanner. The values of correlation coefficient (r) and root meansquare percent deviation were noted as r = 0.99 and e = 7.52 andit indicated a fair agreement between theoretically calculatedand experimentally measured values. Fig. 11 shows the thermalcharacteristic curve in which instantaneous thermal efficiency

have been plotted with respect to ðTm�TaÞIb

h i: The characteristic equa-

tions have been developed by linear regression analysis. Followingare the characteristic equations for the instantaneous thermal effi-ciency for various cases:

For [case (A)] conventional CPC system

gi ðin fractionÞ ¼ 0:74� 3:79Tm � Ta

Ib

� �ð26Þ

For [case (B)] fully covered PVT-CPC system

gi ðin fractionÞ ¼ 0:31� 5:10Tm � Ta

Ib

� �ð27Þ

For PVT system (without CPC system)

gi ðin fractionÞ ¼ 0:55� 4:30Tm � Ta

Ib

� �ð28Þ

where, Tm ¼ ðTfoþTfiÞ2

h i

4th May, 2016).

2) Id (W/m2) Ib (W/m2) Isc (A) Voc (V) IL (A) VL (V)

99.00 511.90 2.2 19.25 0.2 15.72127.67 647.93 2.3 19.09 0.2 15.69100.50 790.00 2.4 18.73 0.2 15.48118.00 831.00 2.4 18.56 0.3 15.39153.00 797.00 2.5 17.43 0.3 15.73179.00 708.53 2.4 17.23 0.3 15.56139.00 623.00 2.3 17.36 0.2 15.43109.00 473.10 2.2 18.12 0.2 15.3391.00 280.00 2.1 18.40 0.2 15.23

Page 9: Experimental validation of a fully covered photovoltaic ... · system. It was found that partially covered PVT-CPC system has a superior thermal performance than fully covered PVT-CPC

09:00 10:00 11:00 12:0010

20

30

40

50

60

Out

let f

luid

tem

pera

ture

Tfo

1, o C

Tim

Theoretical [ e = 2.68, r = Experimental, 3rd May 20 Theoretical [ e = 2.40, r= Experimental, 4th May 20

Fig. 9. Hourly variation of theoretically calculated and experimentally evaluated outletsystem.

09:00 10:00 11:00 12:00 10

1

2

3

4

5

6

7

8

9

10

Inst

anta

neou

s ele

ctric

al e

ffic

ienc

y (η

m ),

%

Tim

Theoretical Experimental (

Fully cove

e=

Fig. 10. Hourly trend of theoretically calculated and experimentally evaluat

Table 3Hourly variation of Ta, Tfi, Tfo1, It, Id, Ib for conventional CPC system for a typical day(3rd May,2016).

S. no. Time(hr)

Ta(�C)

Tfi(�C)

Tfo(�C)

It(W/m2)

Id(W/m2)

Ib(W/m2)

1 9:00 34 33 42 608.84 98 510.842 10:00 35.5 34 46 776.25 125 651.253 11:00 37 36 52 888.40 100 788.404 12:00 39 38 54.5 948.32 115 833.325 13:00 40 40 56 950.82 150 800.826 14:00 41 41.5 57 886.51 175 711.517 15:00 38.5 39 52.8 761.39 136 625.398 16:00 38 38.5 46.6 580.81 100 480.809 17:00 38 38 45 371.43 85 286.43

D. Atheaya et al. / Engineering Science and Technology, an International Journal 19 (2016) 1845–1856 1853

The values of gain factor and loss term for different systemshave been given in Table 4. The instantaneous thermal efficiencyof conventional CPC system was more as compared to the fullycovered PVT-CPC system and PVT system (without CPC system)owing to maximum gain factor and minimum loss term. TheFig. 12 shows the hourly trend of theoretically calculated andexperimentally evaluated absorber plate temperature, Tp (�C) forfully covered PVT-CPC system. It can be noted from the above fig-ure that the absorber plate temperature varied in the range of 38–55 �C which was higher than the outlet fluid temperature. Thelosses were also less as the fluid (water in this case) flows belowthe plate. The small increase in absorber plate temperature overthe period (12.00–17.00) when the solar radiation decreases over

13:00 14:00 15:00 16:00 17:00

e, hour

0.99 ] [case(A)]16, New Delhi [case(A)] 0.99 ] [case(B)]16, New Delhi [case(B)]

fluid temperature Tfo1, �C for conventional CPC system and fully covered PVT-CPC

3:00 14:00 15:00 16:00 17:00

e, hour

4th May 2016, New Delhi)

red PVT-CPC system

7.52 ; r = 0.99

ed instantaneous electrical efficiency for fully covered PVT-CPC system.

Page 10: Experimental validation of a fully covered photovoltaic ... · system. It was found that partially covered PVT-CPC system has a superior thermal performance than fully covered PVT-CPC

0.005 0.010 0.015 0.020 0.025 0.0300.0

0.2

0.4

0.6

0.8

1.0

Inst

anta

neou

s the

rmal

eff

icie

ncy

η i, in

frac

tion

(Tm-Ta)/Ib, oCm2/W

Conventional CPC system Fully covered PVT-CPC system PVT system (without CPC)

Fig. 11. Thermal characteristic curve for conventional CPC system, fully covered PVT-CPC system and PVT system (without CPC).

Table 4Values of gain factor and loss coefficient for different systems.

System Gain factor Loss term

Conventional CPC system [case (A)] 0.74 3.79PVT-CPC system PVT-CPC system [case (B)] 0.31 5.10PVT system (without CPC system) 0.55 4.30

1854 D. Atheaya et al. / Engineering Science and Technology, an International Journal 19 (2016) 1845–1856

this period was due to the (i) lower value of solar radiation avail-able and (ii) reduced top loss coefficient. The values of correlationcoefficient and the root mean square percent deviation were

09:00 10:00 11:00 12:00 10

10

20

30

40

50

60

Abs

orbe

r pla

te te

mpe

rture

, o C

Tim

Fully covered PV

r = 0.99e = 3.15

Fig. 12. Hourly trend of theoretically calculated and experimentally evaluate

r = 0.99 and e = 3.15 which showed a good agreement between the-oretically calculated and experimentally evaluated values.

The Fig. 13 shows the monthly variation of thermal exergy gain,overall exergy gain as well as an overall thermal energy gain inkW h for cases (A) and (B). The output daily thermal exergy hasbeen calculated by using Eq. (21). Further, the output exergy forevery month has been calculated by multiplying type of days (a–d) with daily thermal exergy output and adding them altogether.Similarly, the monthly overall exergy gain and monthly overallthermal energy output has been evaluated by the help of Eqs.(20) and (23). The maximum and minimum overall thermal energy

3:00 14:00 15:00 16:00 17:00

e, hour

TheoreticalExperimental (4th May, 2016)

T-CPC system

d absorber plate temperature, Tp (�C) for fully covered PVT-CPC system.

Page 11: Experimental validation of a fully covered photovoltaic ... · system. It was found that partially covered PVT-CPC system has a superior thermal performance than fully covered PVT-CPC

JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC0

20

40

60

80

100

120

140

Ove

rall

exer

gy g

ain,

kW

h

Month of year

thermal exergy gain of conventional CPC system, [case (A)] overall exergy gain of fully covered PVT-CPC water system, [case (B)] overall thermal energy gain of fully covered PVT-CPC system, [case (B)]

Fig. 13. Monthly variation of thermal exergy gain, overall exergy gain and overall thermal energy gain for [case (A)] and [case (B)].

D. Atheaya et al. / Engineering Science and Technology, an International Journal 19 (2016) 1845–1856 1855

gain of fully covered PVT-CPC systemwas in the April and Februarymonth. Also from the figures it can be seen that the thermal exergygain of conventional CPC system [case (A)] was maximum for thesummer month of April and minimum in the winter month ofDecember. Also, it can be observed from the Fig. 13 that overallexergy gain was highest in the month of May due to high solarradiation values.

9. Conclusions

In this research paper, a conventional CPC system [case (A)] anda fully covered PVT-CPC system [case (B) have been set up and thetheoretical modeling has been done to analyze the systems. Anexperimental investigation was conducted on both the systems.The following conclusions have been drawn from the experimentalvalidation of conventional CPC system and fully covered PVT-CPCsystem.

(i) The validation results indicate a close match between theo-retical values and experimental values.

(ii) In case of end user priority only for thermal energy genera-tion, the conventional CPC system is the best.

(iii) The fully covered PVT-CPC system is preferred where elec-tricity generation along with relatively low outlet tempera-ture is the end user’s priority. In addition, it was alsonoted that overall maximum thermal energy gain (fromFig. 13) was found to be 118 kW h for the month of April.

Appendix A

The expression for various constants used in Eqs. (1) and (2) are

ðasÞc;eff ¼ qapsgAa

Ar

Ul;c ¼ hpf � Ut;pa

ðF 0 � hpf Þ þ Ut;pa

Ut;pa ¼ 1hi

þ LgKg

þ 1ho

� ��1

þ LiKi

þ 1hi1

� ��1

Fr1 ¼ _mf cfUl;cAr

1� exp�F 0Ul;cAr

_mf cf

� �� �

Constants for Eqs. (5) and (9) are

ðasÞ2;eff ¼ qaps3gð1� bCÞAa

Ar; ðasÞ1;eff ¼ qðaCbCs2g � gmÞ

Aa

Ar

PF1 ¼ Ut;cp

Ut;cp þ Ut;ca

UL1 ¼ Ut;ca � Ut;cp

ðUt;ca þ Ut;cpÞ

ðasÞm;eff ¼ ðasÞ2;eff þ PF1ðasÞ1;eff¼ ðasÞ2;eff þ PF1 � qðaCbCs2g � gmÞ

Aa

Ar

� �

PF2 ¼ hpf

F 0hpf þ UL1; ðasÞm;eff ¼ ðasÞ2;eff þ PF1 � ðasÞ1;eff

Ul;m ¼ UL1 � hpf

F 0hpf þ UL1

References

[1] A. Agarwal, R.M. Sarviya, An experimental investigation of shell and tube latentheat storage for solar dryer using paraffin wax as heat storage material, Eng.Sci. Technol., Int. J. 19 (2016) 619–631.

[2] P.P. Nayak, J.P. Dutta, G.P. Mishra, Efficient InGaP/GaAs DJ solar cell withdouble back surface field layer, Eng. Sci. Technol., Int. J. 18 (2015) 325–335.

[3] V. Kaundal, A.K. Mondal, P. Sharma, K. Bansal, Tracing of shading effect onunderachieving SPV cell of an SPV grid using wireless sensor network, Eng. Sci.Technol., Int. J. 18 (2015) 475–484.

[4] A. Rabl, Optical and thermal properties of compound parabolic concentrators,Sol. Energy 18 (1976) 497–511.

[5] C. Gibart, Study of and tests on a hybrid photovoltaic –thermal collector usingconcentrated sunlight, Sol. Cells 4 (1981) 71–89.

Page 12: Experimental validation of a fully covered photovoltaic ... · system. It was found that partially covered PVT-CPC system has a superior thermal performance than fully covered PVT-CPC

1856 D. Atheaya et al. / Engineering Science and Technology, an International Journal 19 (2016) 1845–1856

[6] L. Tan, X. Ji, M. Li, C. Leng, X. Luo, H. Li, The experimental study of a two-stagephotovoltaic thermal system based on solar trough concentration, EnergyConvers. Manage. 86 (2014) 410–417.

[7] T.K. Mallick, P.C. Eames, T.J. Hyde, B. Norton, The design and experimentalcharacterisation of an asymmetric compound parabolic photovoltaicconcentrator for building facade integration in the UK, Sol. Energy 77 (2004)319–327.

[8] A. Kribus, D. Kaftori, G. Mittelman, A. Hirshfeld, Y. Flitsanov, A. Dayan, Aminiature concentrating photovoltaic and thermal system, Energy Convers.Manage. 47 (2006) 3582–3590.

[9] C. Kong, Z. Xu, Q. Yao, Outdoor performance of a low-concentratedphotovoltaic–thermal hybrid system with crystalline silicon solar cells, Appl.Energy 112 (2013) 618–625.

[10] H. Chen, J. Ji, Y. Wang, W. Sun, G. Pei, Z. Yu, Thermal analysis of a highconcentration photovoltaic/thermal system, Sol. Energy 107 (2014) 372–379.

[11] G. Xu, X. Zhang, S. Deng, Experimental study on the operating characteristics ofa novel low-concentrating solar photovoltaic/thermal integrated heat pumpwater heating system, Appl. Therm. Eng. 31 (2011) 3689–3695.

[12] R. Kunnemeyer, T.N. Anderson, M. Duke, J.K. Carson, Performance of a V-troughphotovoltaic/thermal concentrator, Sol. Energy 101 (2014) 19–27.

[13] G. Li, G. Pei, J. Ji, Y. Su, Outdoor overall performance of a novel air-gap-lens-walled compound parabolic concentrator (ALCPC) incorporated withphotovoltaic/thermal system, Appl. Energy 144 (2015) 214–223.

[14] M. Mohsenzadeh, R. Hosseini, A photovoltaic/thermal systemwith acombination of a booster diffuse reflector and vacuum tube for generation ofelectricity and hot water production, Renew. Energy 78 (2015) 245–252.

[15] A.M. Elsafi, P. Gandhidasan, Comparative study of double-pass flat andcompound parabolic concentrated photovoltaic–thermal systems with andwithout fins, Energy Convers. Manage. 98 (2015) 59–68.

[16] D. Atheaya, A. Tiwari, G.N. Tiwari, I.M. Al-Helal, Analytical characteristicequation for partially covered photovoltaic thermal (PVT) compound parabolicconcentrator (CPC), Sol. Energy 111 (2015) 176–185.

[17] D.L. Evans, Simplified method for predicting PV array output, Sol. Energy 27(1981) 555–560.

[18] T. Schott, Operational temperatures of PV modules, in: Proceedings of 6th PVSolar Energy Conference, 1985, pp. 392–396.

[19] G.N. Tiwari, R.K. Mishra, S.C. Solanki, Photovoltaic modules and theirapplications: a review on thermal modeling, Appl. Energy 88 (2011) 2287–2304.

[20] A. Hepbasli, A key review on exergetic analysis and assessment of renewableenergy resources for a sustainable future, Renew. Sustain. Energy Rev. 12(2008) 593–661.

[21] S.C. Chapra, R.P. Canale, Numerical Methods for Engineers, McGraw Hill, N.Y.,2006.