Experimental set-up Germanium detector (under vacuum; 4cm from target) Ionization chamber (12 cm...

11
Experimental set-up Germanium detector (under vacuum; 4cm from target) Ionization chamber (12 cm from the target) Double-side strip Si detector CsI detectors from INDR (ring 13_17)

Transcript of Experimental set-up Germanium detector (under vacuum; 4cm from target) Ionization chamber (12 cm...

Page 1: Experimental set-up Germanium detector (under vacuum; 4cm from target) Ionization chamber (12 cm from the target) Double-side strip Si detector CsI detectors.

Experimental set-up

Germanium detector (under vacuum; 4cm from target)

Ionization chamber(12 cm from the target)

Double-side strip Si detector

CsI detectors from INDRA(ring 13_17)

Page 2: Experimental set-up Germanium detector (under vacuum; 4cm from target) Ionization chamber (12 cm from the target) Double-side strip Si detector CsI detectors.

Vue de dessus

Page 3: Experimental set-up Germanium detector (under vacuum; 4cm from target) Ionization chamber (12 cm from the target) Double-side strip Si detector CsI detectors.
Page 4: Experimental set-up Germanium detector (under vacuum; 4cm from target) Ionization chamber (12 cm from the target) Double-side strip Si detector CsI detectors.

4/ 5 FluoXLE GALLIARD Ch. – IPNO –Service R&D Détecteur – Août 2012

Approche d’Indra de l’enceinte avec une « girafe »Et un contre poids

Contre Poids

Indra

NouvelleEnceinte

FluoX

Nouvelle Plaque intermédiaire

FluoX / Enceinte

Elingue

Fluo X / Indra

Page 5: Experimental set-up Germanium detector (under vacuum; 4cm from target) Ionization chamber (12 cm from the target) Double-side strip Si detector CsI detectors.
Page 6: Experimental set-up Germanium detector (under vacuum; 4cm from target) Ionization chamber (12 cm from the target) Double-side strip Si detector CsI detectors.
Page 7: Experimental set-up Germanium detector (under vacuum; 4cm from target) Ionization chamber (12 cm from the target) Double-side strip Si detector CsI detectors.

Brides:

1 bride pour 3 Si (6 PAC) 1 bride pour 2 Si (4 PAC) + CHIO (9 signaux et 9 tensions et géné?)1 bride pour CsI (72 signaux et 72 tensions)1 bride pour plastiques1 bride pour passages de gaz1 bride pour pompage

Volume à pomper : 0.3 m3

Page 8: Experimental set-up Germanium detector (under vacuum; 4cm from target) Ionization chamber (12 cm from the target) Double-side strip Si detector CsI detectors.
Page 9: Experimental set-up Germanium detector (under vacuum; 4cm from target) Ionization chamber (12 cm from the target) Double-side strip Si detector CsI detectors.

5 ADC (portes indiv.)1 ADC / Si

1 ADC (porte comm.) CHIOS + Ge+

Plastiques

1 TDC

VXI INDRA:1 Sélecteur1 corrélateur3 modules CSI1 Marqueur temps

VME:1 V1724 Caen

HT INDRA Commandes?

Page 10: Experimental set-up Germanium detector (under vacuum; 4cm from target) Ionization chamber (12 cm from the target) Double-side strip Si detector CsI detectors.
Page 11: Experimental set-up Germanium detector (under vacuum; 4cm from target) Ionization chamber (12 cm from the target) Double-side strip Si detector CsI detectors.