Experience from the Spallation Neutron Source Commissioning Dong-o Jeon Accelerator Physics Group Oak Ridge National Laboratory May 9, 2007

description

Experience from the Spallation Neutron Source Commissioning. Dong-o Jeon Accelerator Physics Group Oak Ridge National Laboratory May 9 , 200 7. Diagnostics on Diagnostics-plate used for commissioning DTL Tank 1. Bunch Shape Monitor (BSM). - PowerPoint PPT Presentation

Transcript of Experience from the Spallation Neutron Source Commissioning

Page 1: Experience from the Spallation Neutron Source Commissioning

Experience from the Spallation Neutron Source Commissioning

Dong-o JeonAccelerator Physics GroupOak Ridge National Laboratory

May 9, 2007

Page 2: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Diagnostics on Diagnostics-plate used for commissioning DTL Tank 1

Bunch Shape Monitor

(BSM)

Bunch Shape Monitor installed 50 inches downstream of DTL1

Page 3: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

DTL diagnostics devices

Wire-scanners

Beam Position Phase Monitors

Energy Degrader / Faraday Cup

Beam Loss Monitors

Beam Current Monitors

Page 4: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

CCL diagnostics devices

Wire-scanners

Bunch Shape Monitors (Z-profile)

Beam Position Phase Monitors

Beam Loss Monitors, Neutron Detectors

Beam Current Monitor

Page 5: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

SCL diagnostics devices

Laser Profile Monitors

Beam Position Phase Monitors

Beam Loss Monitor, Neutron Detectors

Beam Current Monitor

Bunch Shape Monitor will be installed.

Page 6: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Emittance scanner is most valuable

Provides direct information about beam quality.

Can perform transverse matching.

Essential for physics studies, providing decisive information of interesting mechanisms.

Wire-scanners and Laser Profile Monitors Provide information about beam profile.

Limited compared with emittance scanner

Can perform transverse matching.

Laser Profile Monitors commissioned, almost ready…

Page 7: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Transverse matching by minimizing rms emittance @ 38mA, nominal optics

design before afterQH12: -25.96 T/m -26.12 T/m -28.31 T/mQH14: -18.50 T/m -17.31 T/m -16.86 T/m

After MatchingBefore Matching

• RMS with 1% threshold: 0.31 0% threshold: 0.39• Gaussian fit to core: 0.19

• RMS with 1% threshold: 0.42 mm mrad 0% threshold: 0.50• Gaussian fit to core: 0.23

Page 8: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Round Beam Optics improves X beam quality (Emittance Measurement)

Round Beam Optics reduces halo and rms emittance in X significantly

Nominal OpticsX= 0.349 mm-mrad (1% threshold) 0.454 mm-mrad (0% threshold)

Round Beam OpticsX= 0.231 mm-mrad (1% threshold) 0.289 mm-mrad (0% threshold)

Page 9: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Tail is significantly reduced in X plane for Round Beam Optics

Round Beam Optics reduces beam tail visibly

Rare measurement data with no tail!

Tail is the source of beam loss

Page 10: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Redundant diagnostics matters emittance data and wire-scanner

X beam size from emittance data is ~1.5 times bigger than that from wire scanner data.

Y beam size from emittance is consistent with that from wire scanner data.

Beam profile fromEmittance data

Beam profile from Wire scanner

Page 11: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Comparison of beam profile from emittance data and wire-scanner

Page 12: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Comparison of beam profile from emittance data and wire-scanner

Page 13: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Comparison of Measured Beam Profiles with Model

• Fit of starting twiss to beam profiles using online model delivers matched beam in DTL

-3

-2

-1

0

1

2

3

4

0 2 4 6 8 10

s (m)

siz

e (

mm

) horizontal model

vertical model

Horizontal wire

Vertical wire

Page 14: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Laser Profile Monitor This is a new way of diagnosing the transverse profile of

an H- beam.

R&D, implementation, and commissioning at the same time!!

LW04 Hor. 30 steps at 0.5mm each. analysis: average. time: 10:58

LW04, vertical, quads at nominal setting

Courtesy of S. Assadi et al

Page 15: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Beam Phase Monitors and Energy Degrade/Faraday Cup

Beam Phase Monitors can provide information about tank rf amplitude, phase (A, ) and incoming beam energy deviation E

ED/FC generally can not determine E

ED/FC gives information of longitudinal beam profile.

Page 16: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Acceptance Scan for DTL

Acceptance of DTL Tank 1

Results depend on incoming beam energy E

Acceptance Scan technique generally can not determine E

Page 17: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

DTL tanks rf set-point by Acceptance Scan with Absorber/Collector

Measurements consistent with simulations

Used to establish proper amplitude and phase setpoints

Measured bunch width consistent with MEBT design

FWHM = 28.8 deg

Simulated DTL1 Acceptance

Cur

rent

[mA

]

Tank 1 RF Phase [deg]

Bea

m P

rofil

e [a

.u.]

Page 18: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Beam bunch length at the entrance of DTL tanks obtained from Acceptance Scans

Z beam size @ DTL 1 entrance is consistent with model 28.8 deg vs. 26.7 deg FWHM.

Z beam size remains consistent with the model beam distribution we used.

Page 19: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Only DTL Tank 1 shows variations enough to detect the incoming beam energy deviation E

Data noisy!

E [MeV]

Acceptance Scan generally can not determine E

Page 20: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Multiparticle Phase Scan for DTL

Schematic drawing

Multiparticle model

Single-particle model

Why Multiparticle Phase Scan?

When beam bunch is long,

Single particle tracking is not

accurate enough.

Page 21: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Multiparticle Phase Scan vs Acceptance Scan

For low energy DTL tanks, beam bunch length is relatively long and it is important to do multiparticle tracking to accurately simulate the phase scan.

Agreement between measurement and simulation is excellent.

Agreement between multiparticle phase scan and acceptance scan is excellent.

DTL 1 Multiparticle Phase Scan DTL 1 Acceptance Scan

(A, )=(0.179, -125.5) (A, )=(0.176, -124.6)

E=-0.0265MeV, -1.06%

Page 22: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Multiparticle Phase Scan vs Acceptance Scan

Agreement between measurement and simulation is excellent.

Agreement between multiparticle phase scan and acceptance scan is excellent.

DTL 2 Multiparticle Phase Scan DTL 2 Acceptance Scan

(A, )=(0.483, 166.5) E=-0.314% (A, )=(0.484, 168.0)

Page 23: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Multiparticle Phase Scan vs Acceptance ScanDTL 3 Multiparticle Phase Scan DTL 3 Acceptance Scan

(A, )=(0.490, 105.0) E=0.254% (A, )=(0.494, 104.7)

Set-points from the phase scan and acceptance scan are consistent with each other within ±2% and ±2º.

Page 24: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Phase Scan Acceptance Scan

DTL 1 (0.179, -125.5) (0.176, -124.6)

DTL 2 (0.483, 166.5) (0.484, 168.0)

DTL 3 (0.490, 105.0) (0.494, 104.7)

DTL 4 (0.599, 181.6) (0.585, 180.0)

DTL 5 (0.576, 116.6) (0.547, 112.0)

Multiparticle Phase Scan vs Acceptance Scan Summary

Set-points from the phase scan and acceptance scan are consistent with each other within ±2% and ±2º, except Tank 5.

Noisy Acceptance Scan data for DTL Tank 5 is an issue

Page 25: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Longitudinal beam profile

Bunch Shape Monitors (INR)

Mode locked Laser Profile monitor

Energy Degrader/Faraday Cup

Page 26: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Bunch Shape Monitor (BSM) Measurements

020

4060

8010

30

50

70

0

1

2

3

4

5

6

7

8

Phase, deg 402.5 MHz

Time, us

• INR Collaborators produced Bunch Shape Monitor (Feschenko, Jeon, Blokland et al.)

• Early BSM measurements indicated poor phase stability• Tracked to MEBT Rebuncher RF System

Page 27: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Longitudinal Emittance at DTL1 Input Estimated Using the BSM

-0.10

-0.08

-0.06

-0.04

-0.02

0.00

0.02

0.04

0.06

0.08

0.10

-0.50 -0.40 -0.30 -0.20 -0.10 0.00 0.10 0.20 0.30 0.40 0.50

Phase, rad

En

erg

y D

evia

tio

n,

MeV

Tank 1 Entrance

Tank 1 Exit

BSM

Parameter list: 0.13 pi MeV-deg (RMS) for 38 mA

Estimated longitudinal emittance: 0.14 pi MeV-deg for 15 mA

-0.10

-0.08

-0.06

-0.04

-0.02

0.00

0.02

0.04

0.06

0.08

0.10

-0.5 -0.4 -0.3 -0.2 -0.1 0 0.1 0.2 0.3 0.4 0.5

Phase, rad

En

erg

y d

evia

tio

n,

MeV

E=0.94EoE=0.94EoE=0.97EoE=0.97EoE=1.00EoE=1.00EoE=1.03EoE=1.03EoE=1.06EoE=1.06EoE=1.09EoE=1.09EoE=1.12EoE=1.12EoE=1.15EoE=1.15EoEquivalent Ellipse

Feschenko, Jeon et al. (INR)

Page 28: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Now have mode-locked laser diagnostics for 3-dimensional profile measurement in MEBT (only longitudinal has been commissioned)

Longitudinal laser bunch profile monitor in MEBT

Longitudinal bunch profile (blue dots) and Gaussian fit (red line).

Courtesy of A. Aleksandrov et al

measurement

simulation

rebuncher phase

bun

ch s

ize

Page 29: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Longitudinal beam profile from Acceptance Scan

Comparable quality to Mode-locked Laser Profile Monitor measurement

Page 30: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Beam Loss Monitors

500 sec, peak = 0.004

Loss units in Rads/pulse

From loss studies calibrations, the peak loss (next to the linac dump window) ~ 2 W/m at 1 Hz

Linac dump window

SCL/HEBT transition

Page 31: Experience from the Spallation Neutron Source Commissioning

OAK RIDGE NATIONAL LABORATORY

Conclusions

Emittance scanners are very valuable for commissioning and future beam physics studies. SNS used to have once and gone!

Redundant diagnostics devices can play an important role … cross checking, backup.

Preplanning and testing of diagnostics are crucial … otherwise one might end up using the commissioning period in commissioning diagnostics devices.

LINAC4 … Uniquely positioned to carry out many valuable physics studies.