Existing South Elevation Ground Floor Level - Existing · 2020-05-12 · NORTH ELEVATION SOUTH...

1
001 4 001 001 3 2 Lounge Kitchen / Diner Bathroom Bedroom Bedroom Bedroom Office WC Store APP RO X BOUNDARY LINE EAST ELEVATION NORTH ELEVATION SOUTH ELEVATION Hallway GF - Ground Floor Level 0 00 - External Site Level - 225 Concrete roof tiles White UPVC fascias & soffits Black gutters and rainwater pipes Brown/red brick external walls White UPVC framed double glazed windows GF - Ground Floor Level 0 00 - External Site Level - 225 GF - Ground Floor Level 0 00 - External Site Level - 225 project: client: title: drawing no: Rev: scale: date: Status: @A3 This drawing is copyright and owned by Dan Worden Architecture and may not be reproduced or used unless accepted in writing. DO NOT SCALE this drawing (printed or electronic versions). Contractors must check all dimensions from site. All other design discipline elements other than specified architectural elements, have been imported from the relevant consultant's drawings and reference should be made to the individual consultant's drawings for their specific elements of work. Discrepancies and / or ambiguities within this drawing, between it and information given elsewhere, must be reported immediately to Dan Worden Architecture for clarification before proceeding. All works are to be carried out in accordance with the latest CDM Safety Standard, Building Regulations, British Standards and Industry Codes of Practice unless specifically directed otherwise. Responsibility for the reproduction of this drawing in paper form, or if issued in electronic format, lies with the recipient to check that all information has been replicated in full and is correct when compared to the original paper or electronic image. Graphical representations of equipment on this drawing have been co - ordinated, but are approximations only. Please refer to the Specifications and / or Details for actual sizes and / or specific contractor construction information. This original document is issued for the purpose indicated below and contains information of confidential nature. Further copies and circulation will be strictly in accordance with the confidentiality agreement under the contract. This original must be destroyed or returned to the contractor. project no: 1 2 3 4 5 6 7 8 Tel: - A drawn by: VISUAL SCALE 1:50 @ A1 5m 1m 4m 3m 2m 0m 1 . project identifier - 2 . originator - 3 . zone - 4. level - 5. drawing type - 6. discpline ref - 7. series - 8. sheet number Drawing Numbering Key: Email: Web: 07581 584180 [email protected] danwordenarchitecture.co.uk Dan Worden A A Ar r rc c ch h hi i it t te e ec c ct t tu u ur r re e e P02 1 : 50 Mr Steve Eldridge Single Storey Rear Extension - 16 Windsor Close, Read Existing Plans & Elevations S0 02/28/20 -XX 123456 -DWA -DR -XX DW -001 Revision Schedule rev description date drawn P01 Issued for Review 29.02.20 DW P02 Issued for Planning 29.03.20 DW WCR 1 : 50 Ground Floor Level - Existing 1 EXISTING SITE PHOTOS Photograph of front of property Photograph of rear of property Photograph of bedrooms which are proposed to be extended 1 : 50 Existing East Elevation 2 1 : 50 Existing North Elevation 3 1 : 50 Existing South Elevation 4

Transcript of Existing South Elevation Ground Floor Level - Existing · 2020-05-12 · NORTH ELEVATION SOUTH...

Page 1: Existing South Elevation Ground Floor Level - Existing · 2020-05-12 · NORTH ELEVATION SOUTH ELEVATION Hallway GF - Ground Floor Level 0 00 - External Site Level-225 Concrete roof

0014

001

001

3

2

Lounge

Kitchen / DinerBathroomBedroom

Bedroom

Bedroom Office

WC

Store

AP

PR

OX

BO

UN

DA

RY

LI N

E

EAST ELEVATION

NO

RT

H E

LE

VA

TIO

N

SO

UT

H E

LE

VA

TIO

N

Hallway

GF - Ground Floor Level

0

00 - External Site Level

-225

Concrete roof tiles

White UPVC fascias & soffits

Black gutters and rainwater pipes

Brown/red brick external walls

White UPVC framed double glazed windows

GF - Ground Floor Level

0

00 - External Site Level

-225

GF - Ground Floor Level

0

00 - External Site Level

-225

project:

client:

title:

drawing no: Rev:

scale: date:

Status:

@A3

This drawing is copyright and owned by Dan Worden Architecture and may not be reproduced or used unless accepted in writing.

DO NOT SCALE this drawing (printed or electronic versions). Contractors must check all dimensions from site.

All other design discipline elements other than specified architectural elements, have been imported from the relevant consultant's drawings and reference should be made to the individual consultant's drawings for their specific elements of work.

Discrepancies and / or ambiguities within this drawing, between it and information given elsewhere, must be reported immediately to Dan Worden Architecture for clarification before proceeding.

All works are to be carried out in accordance with the latest CDM Safety Standard, Building Regulations, British Standards and Industry Codes of Practice unless specifically directed otherwise.

Responsibility for the reproduction of this drawing in paper form, or if issued in electronic format, lies with the recipient to check that all information has been replicated in full and is correct when compared to the original paper or electronic image. Graphical representations of equipment on this drawing have been co-ordinated, but are approximations only. Please refer to the Specifications and / or Details for actual sizes and / or specific contractor construction information.

This original document is issued for the purpose indicated below and contains information of confidential nature. Further copies and circulation will be strictly in accordance with the confidentiality agreement under the contract. This original must be destroyed or returned to the contractor.

project no:

1 2 3 4 5 6 7 8

Tel:

-A

drawn by:

VISUAL SCALE 1:50 @ A1

5m1m 4m3m2m0m

1. project identifier - 2. originator - 3. zone - 4. level - 5. drawing type -6. discpline ref - 7. series - 8. sheet number

Drawing Numbering Key:

Email:

Web:

07581 584180

[email protected]

danwordenarchitecture.co.uk

Dan Worden AAAArrrrcccchhhhiiiitttteeeeccccttttuuuurrrreeee

P02

1 : 50

Mr Steve Eldridge

Single Storey Rear Extension - 16 Windsor Close, Read

Existing Plans & Elevations

S0

02/28/20

-XX

123456

-DWA -DR-XX

DW

-001

Revision Schedule

rev description date drawn

P01 Issued for Review 29.02.20 DW

P02 Issued for Planning 29.03.20 DW

WCR

1 : 50

Ground Floor Level - Existing1

EXISTING SITE PHOTOS

Photograph of front of property Photograph of rear of property Photograph of bedrooms which are proposed to be extended

1 : 50

Existing East Elevation2

1 : 50

Existing North Elevation3

1 : 50

Existing South Elevation4