EXHAUSTO Inc in North America - Wesmech · PDF fileSub Title EXHAUSTO Inc in North America...

download EXHAUSTO Inc in North America - Wesmech · PDF fileSub Title EXHAUSTO Inc in North America • In Atlanta since 1990 • 25,000 sq.ft. office and warehouse • 86 authorized sales

If you can't read please download the document

Transcript of EXHAUSTO Inc in North America - Wesmech · PDF fileSub Title EXHAUSTO Inc in North America...

  • Sub Title

    EXHAUSTO Inc in North America

    In Atlanta since 1990 25,000 sq.ft. office and

    warehouse 86 authorized sales

    and service offices in USA and Canada.

  • Sub Title

    The First Fan - 1957

    The first chimney fan - a first worldwide and the foundation of EXHAUSTOs existence

  • Sub Title

    A 50-year Old Company

    Founded in 1957 300,000+ sq.ft. of

    manufacturing and administration

    High-tech ISO 9001 certified manufacturing facilities

  • Sub Title

    Certifications

  • Sub Title

    Mechanical Draft Systems

  • Sub Title

    Products RSV Fan

    3/16 Cast aluminum housingHinged for easy service and cleaningDirect driveClass H insulated motorMaintenance free482 F Continuous Duty575 F Intermittent DutyUL 378 Draft Equipment

    Capacity:

    6,000 MBH on CAT I Appliances

    10,000 MBH on CAT IV Appliances

  • Sub Title

    Products RSV Fan

    The RSV fan can vent all appliance categories with or without barometric dampers

    Up to 6,000 - 10,000 MBH High temperature motor

    eliminates the need for secondary fan cooling

    Simple design with few components reduces the risk of failure and simplifies service

  • Sub Title

    CASI Chimney Automation System

  • Sub Title

    RSIB Power Venter

    SS316 constructionRemovable access doorDirect driveClass A insulated motor - eliminates the need for secondary fan coolingMaintenance freeUp to 575 F DutyThe RSIB fan can vent category I, II, III & IV appliancesSimple design with few components reduces the risk of failure and simplifies serviceRSIB is of Type B, Spark Resistant ConstructionUL 378 Draft Equipment

    Capacity:

    8,000 MBH on CAT I Appliances

    15,000 MBH on CAT IV Appliances

  • Sub Title

    RSIF Power Venter

    Rated to 400F non-condensing applicationsForward inclined impeller. Statically and dynamicallybalanced.Insulated housing in galvanized steelHinged fan housing easily opens to provide easy access to duct and impellerDirect drive, variable speed, TEFC motor located outside housing for easy access.

    Capacity:

    1,800 MBH on CAT I Appliances

  • Sub Title

    Modulating Overdraft Damper System

  • Sub Title

    Controls

    EBC30 Modulating Pressure Control

  • Sub Title

    Controls EBC30

    Features

    100% microprocessor based controlPlug-and-Play initialization processIntegrated PDS function with adjustable time delay Intermittent or continuous operation for all fansField-adjustable PID loopPriority Operation functionBearing Cycle functionRotation Check for three-phase fans

  • Sub Title

    Controls

    Differential pressure transducerEnsures proper draft before and during appliance operationProbe includedRange: 0.04 to 0.60 W.C.

    PDS Proven Draft Switch

  • Sub Title

    Controls

    VFD Variable Frequency Drive

    Pre-programmed from the factory1 5 HP in 200 Volt Class input1 7.All wiring is done externally conduits and wires are pre-installedQuick-menu for field adjustable ParametersNEMA 1 rating

  • Sub Title

    Products Accessories

    SCA Steel Chimney Adapter

    Steel chimney adapterUsed as transition between a round stack and the fanMade of 304 stainless steel

  • Sub Title

    Products Accessories

    BBF Balancing Baffle

    Balancing baffle with flange connectionsFor positive pressure stacksFor balancing pressure drops on systems with multiple appliances

  • Sub Title

    CASV Applications Stack Downsizing

    Hazen High School Renton, WA

    Soldier Field - Chicago, IL

  • Sub Title

    CASV Applications - Aesthetics

    Getty Center Los AngelesRigel San Francisco

  • MCASMechanical Combustion Air Supply Systems

  • Sub Title

    MCAS Modulating Combustion Air Supply System

  • Sub Title

    MCAS Components SFTA Fan

    Fan can be mounted indoors Impeller cast aluminum.Housing in steelDirect drive, variable speed, TEFC motor located outside housing for easy access.Variable Frequency Drive is used on three phase models (VFD should be located inside the building).

    Seven Models1,500 30,000 cfm

  • Sub Title

    MCAS Components BESF/BESB Fan

    Fan can be mounted indoors or outdoors.Impeller - statically and dynamically balanced.Insulated housing in galvanized steelHinged fan housing easily opens to provide easy access to duct and impellerDirect drive, variable speed, TEFC motor located outside housing for easy access.Variable Frequency Drive is used on three phase models In-door or out-door installations(VFD should be located inside the building).

    Seven Models450 5500 cfm

  • Sub Title

    EBC30 Modulating Control

    Chimney Automation

    System

    Modulating Combustion Air Supply

    System

  • Sub Title

    SBC Center San Antonio, TX

    Two 16 inch ducted combustion air inletsInstead of

    Two 10 foot high by 15 foot long Louvers

  • Sub Title

    Lifetime Fitness Savage, MN

  • Sub Title

    Marriott Waterfront Annapolis, MD

    One 24 inch ducted combustion air inletInstead of

    One 90 ft. louver

  • MDVSMechanical Dryer Venting Systems

  • Sub Title

    MDVS Mechanical Dryer Venting System

  • Sub Title

    MDVS Components - BESB Fan

    ETL Listed to UL705 :"The product (BESB/MDVS)covered by this report is a modulating air exhaust system. The product consists of a box ventilator and a modulating control for permanent installation. Its intended use is exhausting of lint-laden air from single or multiple type I and type II residential and commercial clothes dryers whether electric or gas-fired, exhausting commercial hoods, or for providing make-up air for laundries or mechanical rooms. The box ventilator can be installed indoors or outdoors."

    Four Models1200 5500 cfm

  • Sub Title

    MEC 18 Control

    Monitor draft in multi-story building exhaust applicationsControls RSV, EFH, BESF and BESBEBC12 functionsUL 508 and CSA C22.2 Standard for Industrial Control Equipment

  • Sub Title

    Kitchen and Dryer Exhaust

    Madigral Lofts, MD

  • Applications

    Hotels

    Hospitals Fitness Facilities

    Sports Arenas

    Apartments / Condominiums

    Schools

  • Sub Title

    Appliance Categorization

    IV

    III

    II

    I

    Atmospheric

    Fan Assisted(high

    efficiency)

    Forced Draft

    Condensing

    Draft Hood

    Fan AssistedDraft Diverter

    Scotch Marine

    NegativePositive

  • Sub Title

    Z223.1-54 (Venting of equipment)

    12.1 Minimum Safe Performance

    A venting system shall be designed and constructed so as to develop a positive flow adequate to remove flue or vent gases to the outside atmosphere.

    12.4.1 Equipment Draft Requirement

    A venting system shall satisfy the draft requirement of the equipment in accordance with the manufacturers instructions.

  • Sub Title

    Common Code Violations

    (NFPA 54) Z223.1-2006 12.11.9.2 (Venting of Equipment)

    (NFPA 54) Z223.1-2006 13.2 (Sizing of Venting Systems)

  • Sub Title

    Common Code Violations

    (NFPA 54) Z223 Sizing Tables(NFPA 54) Z223.1-2006 13.2.18 (Sizing of Venting Systems)

    3" 4" 5" 6" 7" 8" 9" 10" 12" 14" 16"7" 10" 12" 14" 18" 22" 22" 26" 30" 36" 42"

  • Sub Title

    Mechanical Draft Systems Defined

    12.4.3.1 Mechanical draft systems shall be listed and shall be installed in accordance with the terms of their listing and both the appliance and the mechanical draft system manufacturers instructions.

    12.4.3.2 Appliances requiring venting shall be permitted to be vented by means of mechanical draft systems of either forced or induced draft design.Exception: Incinerators

    12.4.3.5 Where a mechanical draft system is employed, provision shall be made to prevent flow of gas to the main burners when the draft system is not performing so as to satisfy the operating requirements of the equipment for safe performance

    Z223.1-2006 Standard for Venting of Equipment

  • Sub Title

    Commercial Laundry Radisson, Orlando, FL

  • Responsibility

    EnvironmentallyfriendlyReduce Emissions

    Low Energy

    Recyclable Materials

    Demand-Controlled

  • And Still Going Strong...

    Reliable2001

    2 RSV replaced

    Disney Allstar ResortsOrlando, Florida60 RSV installed

    1990

    The White HouseWashington D.C12 RSV installed

    1992

    Sample 3

    xx RSV installed

    2007

  • Seismological Safe

    Eliminates Potential Risks

  • Eliminates Potential Risks

    Seismological Safe

  • Case:CBS Studio, Hollywood, CABoiler replacement. Must meet air quality requirements and eliminate need for substantial stack work.

    Solution:Four condensing boilers installed in a modular system using a single common stack and a CASV system for venting.

    Benefits:Simple and Aesthetically pleasingLimited stack work using existing chase

    EXHAUSTO Inc in North AmericaThe First Fan - 1957A 50-year Old CompanyCertificationsMechanical Draft SystemsSlide Number 6Slide Number 7CASI Chimney Automation SystemRSIB Power Venter RSIF Power VenterModulating Overdraft Damper SystemControlsControls EBC30ControlsSlide Number 15Slide Number 16Slide Number 17CASV Applications Stack DownsizingCASV Applications - AestheticsMCAS Mechanical Combustion Air Supply SystemsMCAS Modulating Combustion Air Supply SystemMCAS Components SFTA FanMCAS Components BESF/BESB FanE