Example(s) of Energy Star Qualified Product Family ... Training - Example(s... · Example(s) of...
Transcript of Example(s) of Energy Star Qualified Product Family ... Training - Example(s... · Example(s) of...
Example(s) of
PRESENTATION TITLE GOES HERE
Example(s) of Energy Star Qualified Product Family
-- a class exerciseRJ Meyers – EPA
John Clinger – ICF InternationalHerb Tan er HPHerb Tanzer - HP
SNIA EmeraldTM TrainingSNIA Emerald Power Efficiency
Measurement SpecificationMeasurement Specification, for use in EPA ENERGY STAR®
June 24-27, 2013
Discussion Framework
Thi i l iThis is a class exercisePick up from the Tuesday topic:“Product/Family Best Foot Forward (BFF) TestProduct/Family, Best Foot Forward (BFF), Test Points and Qualification Ranges”Start with test point(s) from just completed SUT testingRun through the Energy Star qualification rules to identify product family / range / SKUsidentify product family / range / SKUs
2 2
“Qual Table” on the fly
P6500 Test points Qualified
1st Test point(s)Sequential
SUT BFF data
Fixed / Flexible
Other allowances
2nd Test pointsTransactional
Use predicted
Fixed / Flexible
Other Allowances
3rd Test ints Use redicted3rd Test pointsCapacity
Use predicted
SNIA EmeraldTM Training ~ June 24-27, 2013 www.sniaemerald.com 3
Best Foot Forward ApproachScale-Up SystemScale Up System
ce
Approximate region of “best” or peak Performance/W
l” P
erfo
rman
c
Pow
er
“Typ
ical P
Base Performance/W Varying roll-off
behaviors by product.
Base Capacity (Cache, End Storage)
Exercise 3: 128K Sequential Read, Write
Sequential Read1.601.80
MBS/WattSFF 15K rpm, RAID 5
3000
4000
5000
6000Sequential Read
MBS0 400.600.801.001.201.40
Peak Metric:1.63 MB/S/Watt
0
1000
2000
0 100 200 300 400 500
Watts
0.000.200.40
0 100 200 300 400 500
and 25 drives
No. of Disk DrivesNo. of Disk Drives
4000
5000
6000
Sequential Write
0 60
0.80
1.00
1.20MBS/Watt
0
1000
2000
3000
4000
0.00
0.20
0.40
0.60Peak Metric:
1.0 MB/S/Watt and 50 drives
0 100 200 300 400 500
MBS Watts
0 200 400 600
Exercise 1: Mixed Workload8K Random 70/30 R/W
SFF 15K rpm, RAID 530000
IOPs/Watt
000
20000
25000
30000
10.0
12.0
14.0
5000
10000
15000Power
IOPs
2.0
4.0
6.0
8.0
IOPs/Watt
00 100 200 300 400 500
No. of Disk Drives0.0
0 100 200 300 400 500No. of Disk Drives
• Peak metric = 12.7 IOP/S/Watt at 125 drives
• Changing the read/write mix changed the metric but not the drive count60/40 r/w = 11.5 IOP/S/W; 80/20 r/w = 14.9 IOP/S/W60/40 r/w 11.5 IOP/S/W; 80/20 r/w 14.9 IOP/S/W
Exercise 4: Ready-Idle
LFF 2TB 7.2K rpm and SFF 500GB 7.2K rpm drives at Ready-Idle4000
2000
2500
3000
3500
4000
TB Capacity, LFF
0
500
1000
1500
2000Watts Idle, LFF
TB Capacity, SFF
Watts Idle, SFF
120.0
140.0
160.0
0 100 200 300 400 500Drive count
60.0
80.0
100.0
GB/Watt, LFF
GB/Watt, SFF
0.0
20.0
40.0
0 100 200 300 400 500
Peak Metrics:LFF: 138.8 GB/W and 240 drives
Drive countSFF: 76.6 GB/W and 450 drives
Candidate SUT: A shipping Online-3 SAN
Two controller performance points, with variable cache and front end interfacesvariable cache and front-end interfaces
The lower product class can support 120xLFF or 250xSFF and the higher product class can support 240xLFF orproduct class can support 240xLFF or 450xSFF (6Gb SAS)
SFF146GB, 15K300GB, 10K450GB, 10K600GB, 10K500GB, 7.2K midline200GB SSD*400GB SSD*400GB SSD
LFF300GB, 15K450GB, 15K600GB, 15K2TB 7 2K midline2TB, 7.2K midline
HP P6500 SUT setup
SNIA EmeraldTM Training ~ June 24-27, 2013 www.sniaemerald.com 9
Test Results for Candidate SUT(50SFF 148GB 15K)(50SFF, 148GB 15K)
C bi d Vdb h /P A l Pl
P6500 Power Performance Plot
Combined Vdbench /Power Analyzer Plot
1.2
1.4
40
45
SeqR SeqW
P di t 1 63 1 02
0.8
1
25
30
35
W
Seq, R
Seq. W
Predict 1.6325 HDDs
1.0250 HDDs
Data 1.250 HDDs
1.0550 HDDs
0.4
0.6
15
20
25
MB
/s/WIOPs
/ W
IOPs/W
MB/s/W
RR
RW
0
0.2
0
5
10
Ready Idle
SNIA EmeraldTM Training ~ June 24-27, 2013 www.sniaemerald.com 10
Time
“Qual Table” on the fly
P6500 Test points Qualified
1st Test point(s)Sequential
BFF data, (no +/- data)50 x SFF 148GB 15K70/30 workload weigh
Fixed/Flexible/Mixed Fixed (drive count)-40% +15% data-20% +5% qual40 53 d i40 – 53 drives
Drawer rounding 25 – 75 drives
Add’nl drives , samekl d
(BFF data only)workload
Variation / replaceallowances
2nd Test point(s)Transactional
Use BFF prediction as proxy test points
3rd Test point(s)C it
Use BFF prediction as t t i tCapacity proxy test points
SNIA EmeraldTM Training ~ June 24-27, 2013 www.sniaemerald.com 11
ENERGY STAR – further extensions to the Qualification Rangethe Qualification Range
T i i f fi A i Idl di iTest points exist for up to five Active + one Idle conditionsRounding to full drawersCombinations of single device type optimalCombinations of single device type optimal configurations, based on percentage allocation of devicesStorage device replacement (if similar or better)g ( )Multiple device type optimal configurations (must have auto-tiering technology)
A t ti i BFF ti l fi ti i t t f llAuto-tiering BFF or optimal configuration is not yet fully understood, but it is suggested that initial submissions are representative of actual selling systems.M i t i ti f d i t f X% / +Y% t t i tMaintain ratios of device types for –X% / +Y% test points
SNIA EmeraldTM Training ~ June 24-27, 2013 www.sniaemerald.com 12