Example Design of a Cold-Formed Steel Lipped Channel Wall Stud in Compression

4
Document Ref: SX024a-EN-EU Sheet 1 of 3 Title Example: Design of a cold-formed steel lipped channel wall stud in compression CALCULATION SHEET Eurocode Ref EN 1993-1-3 Made by V. Ungureanu, A. Ruff Date Jan 2006 Checked by D. Dubina Date Jan 2006 Example: Design of a cold-formed steel lipped channel wall stud in compression This example deals with the design of a pinned wall stud subjected to compression. The stud is composed of a cold-formed lipped channel section where boards are attached to both flanges and they prevent buckling in the weak direction and torsional buckling. For practical design of light gauge sections to EN1993, designers will normally use software or refer to manufacturers’ data. This example is presented for illustrative purposes Basic Data Height of stud m 75 , 2 = H Spacing between studs m 6 , 0 = S Span of floor m 5 = L Spacing between floor joists m 6 , 0 = S Distributed loads applied to the floor: dead load – lightweight slab 2 m kN 00 , 1 m kN 60 , 0 6 , 0 00 , 1 G = × = q imposed load 2 m kN 50 , 2 m kN 50 , 1 6 , 0 50 , 2 Q = × = q ULS Limit State concentrated load from upper level and roof: kN 0 , 10 = Q The dimensions of one cross-section and the material properties are: Total height mm 0 10 = h Total width of flange mm 40 = b Total width of edge fold mm 15 = c Internal radius mm 3 = r Nominal thickness mm 1 nom = t Steel core thickness mm 96 , 0 = t Basic yield strength 2 yb mm N 350 = f Modulus of elasticity 2 mm N 210000 = E Poisson’s ratio 3 , 0 = ν Shear modulus ( ) 2 mm N 81000 1 2 = + = ν E G Example: Design of a cold-formed steel lipped channel wall stud in compression Discuss me ... Created on 23 May 2013 This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Steelbiz Licence Agreement

description

This example deals with the design of a pinned wall stud subjected to compression. The stud is composed of a cold-formed lipped channel section where boards are attached to both flanges and they prevent buckling in the weak direction and torsional buckling.

Transcript of Example Design of a Cold-Formed Steel Lipped Channel Wall Stud in Compression

Page 1: Example Design of a Cold-Formed Steel Lipped Channel Wall Stud in Compression

Document Ref: SX024a-EN-EU Sheet 1 of 3 Title

Example: Design of a cold-formed steel lipped channel wall stud in compression

CALCULATION SHEET

Eurocode Ref EN 1993-1-3 Made by V. Ungureanu, A. Ruff Date Jan 2006

Checked by D. Dubina Date Jan 2006

Example: Design of a cold-formed steel lipped channel wall stud in compression This example deals with the design of a pinned wall stud subjected to compression. The stud is composed of a cold-formed lipped channel section where boards are attached to both flanges and they prevent buckling in the weak direction and torsional buckling.

For practical design of light gauge sections to EN1993, designers will normally use software or refer to manufacturers’ data. This example is presented for illustrative purposes

Basic Data

Height of stud m75,2=H Spacing between studs m6,0=S Span of floor m5=L Spacing between floor joists m6,0=S Distributed loads applied to the floor: dead load – lightweight slab 2mkN00,1

mkN60,06,000,1G =×=q

imposed load 2mkN50,2

mkN50,16,050,2Q =×=q

ULS Limit State concentrated load from upper level and roof: kN0,10=Q

The dimensions of one cross-section and the material properties are:

Total height mm010=h Total width of flange mm40=b Total width of edge fold mm15=c Internal radius mm3=r

Nominal thickness mm1nom =t

Steel core thickness mm96,0=t

Basic yield strength 2yb mmN350=f

Modulus of elasticity 2mmN210000=E Poisson’s ratio 3,0=ν

Shear modulus ( )2mmN81000

12=

+=

νEG

Example: Design of a cold-formed steel lipped channel wall stud in compression

Discuss me ...C

reat

ed o

n 23

May

201

3T

his

mat

eria

l is

copy

right

- a

ll rig

hts

rese

rved

. Use

of t

his

docu

men

t is

subj

ect t

o th

e te

rms

and

cond

ition

s of

the

Ste

elbi

z Li

cenc

e A

gree

men

t

Page 2: Example Design of a Cold-Formed Steel Lipped Channel Wall Stud in Compression

Document Ref: SX024a-EN-EU Sheet 2 of 3 Title

Example: Design of a cold-formed steel lipped channel wall stud in compression

CALCULATION SHEET

Eurocode Ref EN 1993-1-3 Made by V. Ungureanu, A. Ruff Date Jan 2006

Checked by D. Dubina Date Jan 2006

Partial factors 0,1M0 =γ

0,1M1 =γ

35,1G =γ – permanent loads

50,1Q =γ – variable loads

EN1993-1-3 §2(3) EN1990

Derived data (section properties and action effects) Properties of the gross cross-section

Gross cross-section area: 2mm198=A

Position of z-z axis of the gross cross section with respect to the web:

mm88,12c =y

Properties of the effective cross-section

Effective area of the cross-section in compression: 2eff mm118=A

Position of z-z axis of the effective cross-section with respect to the web:

mm92,15effc, =y

Effective section modulus for bending about weak axis:

3comz,eff, mm1274=W

3tenz,eff, mm2585=W

EN1993-1-3 §5.5.3.1§5.5.3.2EN1993-1-5 §4.4, and SX022, SX023

The applied concentrated load on the stud (only compression)

( ) ( ) kN3,2510550,150,16,035,1QQGGEd =+××+×=++= QLqqN γγ

EN1990

Resistance check of the cross-section

The following condition should be satisfied:

1comRd,cz,

Edz,Edz,

Rdc,

Ed ≤Δ+

+M

MMNN

EN1993-1-3 §6.1.9(1)

Example: Design of a cold-formed steel lipped channel wall stud in compression

Discuss me ...C

reat

ed o

n 23

May

201

3T

his

mat

eria

l is

copy

right

- a

ll rig

hts

rese

rved

. Use

of t

his

docu

men

t is

subj

ect t

o th

e te

rms

and

cond

ition

s of

the

Ste

elbi

z Li

cenc

e A

gree

men

t

Page 3: Example Design of a Cold-Formed Steel Lipped Channel Wall Stud in Compression

Document Ref: SX024a-EN-EU Sheet 3 of 3 Title

Example: Design of a cold-formed steel lipped channel wall stud in compression

CALCULATION SHEET

Eurocode Ref EN 1993-1-3 Made by V. Ungureanu, A. Ruff Date Jan 2006

Checked by D. Dubina Date Jan 2006

where:

M0ybeffRdc, γfAN =

M0ybcomeff,comRd,cz, /γfWM =

NzEdEdz, eNM =Δ

Nze – is the shift of centroidal z-z axis

EN1993-1-3 § 6.1.3

§ 6.1.4

EN1993-1-3 §6.1.9 (2)

0Edz, =M

mm04,35,1592,15ceffc,Nz =−=−= yye

The resistance check is:

1785,00,1350127404,3253000

0,135011825300

<=×

×++

× – OK

Example: Design of a cold-formed steel lipped channel wall stud in compression

Discuss me ...C

reat

ed o

n 23

May

201

3T

his

mat

eria

l is

copy

right

- a

ll rig

hts

rese

rved

. Use

of t

his

docu

men

t is

subj

ect t

o th

e te

rms

and

cond

ition

s of

the

Ste

elbi

z Li

cenc

e A

gree

men

t

Page 4: Example Design of a Cold-Formed Steel Lipped Channel Wall Stud in Compression

Example: Design of a cold-formed steel lipped channel wall stud in compression SX024a-EN-EU

Quality Record

RESOURCE TITLE Example: Design of a cold-formed steel lipped channel wall stud in compression

Reference(s)

ORIGINAL DOCUMENT

Name Company Date

Created by V. Ungureanu, A. Ruff BRITT Ltd. Timisoara, Romania

Technical content checked by D. Dubina BRITT Ltd. Timisoara, Romania

Editorial content checked by

Technical content endorsed by the following STEEL Partners:

1. UK G W Owens SCI 12/4/06

2. France A Bureau CTICM 12/4/06

3. Sweden B Uppfeldt SBI 11/4/06

4. Germany C Müller RWTH 11/4/06

5. Spain J Chica Labein 12/4/06

Resource approved by Technical Coordinator

G W Owens SCI 19/7/06

TRANSLATED DOCUMENT

This Translation made and checked by:

Translated resource approved by:

Example: Design of a cold-formed steel lipped channel wall stud in compression

Discuss me ...C

reat

ed o

n 23

May

201

3T

his

mat

eria

l is

copy

right

- a

ll rig

hts

rese

rved

. Use

of t

his

docu

men

t is

subj

ect t

o th

e te

rms

and

cond

ition

s of

the

Ste

elbi

z Li

cenc

e A

gree

men

t