EWS-100P-36-I SPECIFICATIONworldbatteries.net/PDFs/3030110070spec.pdfTempered & Low Iron Glass /...
Transcript of EWS-100P-36-I SPECIFICATIONworldbatteries.net/PDFs/3030110070spec.pdfTempered & Low Iron Glass /...
► Heavy duty anodized Aluminum frames with predrilled
holes for quick installa�on
► Salt mist corrosion resistance and Ammonia corrosion
resistance
1150 x 675 x 35
Weight (kg)
Moun�ng Holes Pitch (Y) – mm
Cable cross-sec�on
Length x Width x Thickness(L x W x T) - mm
Moun�ng Holes Pitch (X) – mm
Connector (Protec�on degree / Type)
Junc�on Box (Material / Type)
Frame Material
Encapsulate
Front Cover (Material / Thickness)
Solar Cell Type
Solar Cells per Module (Units) /Arrangement
575
633
10,15
36 / (9 x 4)
Mul� Crystalline Silicon
Tempered & Low Iron Glass /3,2mm / 4mm
Ethylene Vinyl Acetate
Anodized Aluminium Alloy
Weatherproof PPO / IP67enclosure with bypass diodes
IP67 rated / MC4 compa�ble 4 mm2
Mechanical Characteris�cs
*Under Standard Test Condi�ons (STC) of 1000 W/m2 irradiance,AM 1,5 spectrum and 25°C cell temperature.
Nominal Maximum Power (Pm) in Wa�s
Power tolerance
Open Circuit Voltage (Voc) in Volts
Short Circuit Current (Isc) in Amps
Voltage at Maximum Power (Vmp) in Volts
Current at Maximum Power (Imp) in Amps
Maximum System Voltage in Volts
Module Efficiency (%)
Maximum Series Fuse Ra�ng (A)
100
0 / + 5W
21,97
6,07
17,46
5,73
1000
12,88
15
Electrical Characteris�cs*
SPECIFICATION SHEETEWS-100P-36-I
Warranty
T 450 348-8720Sans frais/Toll-free: 1 800 661-3330
Distribué par/Distributed by:TCED INTL Inc.
700, chemin du Grand Bernier NordSaint-Jean-sur-Richelieu (Québec) J2W 2H1
Cer�fica�ons
IEC 61701
Thermal Characteris�cs
Opera�ng temperature range (οC)
NOCT (οC)
Temperature coefficient of Power (Pm), γ (%/οC)
Temperature coefficient of Voltage (Voc),ß (%/οC)
Temperature coefficient of Current (Isc), α (%/οC) 0.0681
-0.2941
-0.3845
46 ± 2
-40 to 85
Design specifica�ons
Earth connec�on Moun�ng hole
Junc�on Box
REAR VIEW SIDE VIEW
Y (575 mm)
L (1150 mm)
X (6
33 m
m)
W (6
75 m
m)
T (35 mm)
I-V Curve Varia�on with Irradiance
100 W
81,1 W
61,4 W
41,1 W
20,3 W
Cells temp. = 25�CIncident Irrad. = 1000 W/m2
Incident Irrad. = 800 W/m2
Incident Irrad. = 600 W/m2
Incident Irrad. = 400 W/m2
Incident Irrad. = 200 W/m2
0 5 10 15 20 25Voltage (V)
1
2
3
4
5
6
7
Curr
ent (
A)
- --- ---- ---- ---- ----_ ____
_
_
_
_
_
-
-
-
-
-
-
-
I-V Curve Varia�on with Temperature
Incident Irrad. = 1000 W/m2
Cells temp. = 10�C, Pmpp = 105,7 WCells temp. = 25�C, Pmpp = 100 WCells temp. = 40�C, Pmpp = 94,3 WCells temp. = 55�C, Pmpp = 88,4 WCells temp. = 70�C, Pmpp = 82,5 W
0 5 10 15 20 25Voltage (V)
1
2
3
4
5
6
7
Curr
ent (
A)
- --- ---- ---- ---- ----_ ___
_
_
_
_
_
_
-
-
-
-
-
-
-
EWS-100P-36-I
EWS-100P-36-I
1000 mm
T 450 348-8720Sans frais/Toll-free: 1 800 661-3330
Distribué par/Distributed by:TCED INTL Inc.
700, chemin du Grand Bernier NordSaint-Jean-sur-Richelieu (Québec) J2W 2H1