2
5 Cooling Only Mini Series V-Ph-Hz Capacity kW Power input kW Motor Type Factory charging kg Liquid pipe mm Gas pipe mm 3 m /h dB(A) mm mm kg kg EDVC-V72W/DVN1 7.2 1.64 4.39 4 1.4 Ф9.53 Ф15.9 3400 54 973×862×302 1025×910×410 58 63 EDVC-V92W/DVN1 9.2 2.06 4.47 5 1.4 Ф9.53 Ф15.9 3400 54 973×862×302 1025×910×410 58 63 EDVC-V145W/DVN1 14.5 3.57 4.06 8 2.6 Ф9.53 Ф15.9 5100 55 1053×865×523 1120×890×560 85 92 EDVC-V170W/DVN1 17 3.99 4.26 9 2.6 Ф9.53 Ф15.9 5100 55 1053×865×523 1120×890×560 85 92 °C Model name Power supply 1 Cooling Fan motor DC Quantity Quantity Airow rate Net dimensions (W×H×D) Net weight Gross weight EER Type 1 Compressor Connected indoor units Total capacity Maximum quantity Operating temperature range 1 EDVC-V110W/DVN1 11 2.75 4 6 1.4 Ф9.53 Ф15.9 3400 54 973×862×302 1025×910×410 58 63 1-phase, 220V, 50/60Hz 45-130% of outdoor unit capacity DC inverter Cooling: -5 to 48 R410A Refrigerant Type Pipe connections Notes: 1. Indoor air temperature 27(80.6) DB, 19(66.2) WB; outdoor air temperature 35(95) DB; equivalent refrigerant piping length 7.5m (24.6ft.) with zero level difference. 2. Sound pressure level is measured at a position 1m (3.28ft.) in front of the unit and 1.3m (4.26ft.) above the oor in a semi-anechoic chamber. Specications Controllers Lineup Series Series Capacity range Four-way cassette Compact four-way cassette Low static pressure duct 1.8-7.1kW 2.2-7.1kW 2.8~14kW 1.5~4.5kW 1.8-7.1kW Appearance One-way cassette Two-way cassette Series Capacity range Appearance Wireless remote controller Wired controller Centralized controller & monitor Network control software & gateways Accessories RM05 RM12 RM02 KJR-29B KJR-90D KJR-86C KJR-12B KJR-120C CCM30 MD-CCM09 KJR-90B MD-CCM03 Modbus Gateway CCM-18A LonWorks Gateway LonGW64 IMM Software & M-Interface Data Converter CCM15 KNX Gateway MD-KNX BACnet Gateway CCM08 Hotel Key Card Interface Module MD-NIM05 3-Phase Protector Digital Power Ammeter Infrared Sensor Controller MD-NIM09 AHU Control Box Wall mounted Ceiling & oor 1.5~14kW 7.1~20kW 1.5~9kW 3.6~16kW High static pressure duct Medium static pressure duct 3. For a system with more than one IDU, to ensure even distribution of refrigerant, the capacity of each indoor unit should not exceed 8kW. TRADEMASTER RESOURCES CORPORATION Lot E., Impex Compound, Alabang Zapote Road, Pamplona, Las Piñas City Contact No.: (02) 865-2900 / 872-2222 Visit our website at www.trademaster-philippine.com

Transcript of Everest Cooling Only Mini VRF Series Brochure · MD-NIM05 3-Phase Protector Digital Power Ammeter...

Page 1: Everest Cooling Only Mini VRF Series Brochure · MD-NIM05 3-Phase Protector Digital Power Ammeter Infrared Sensor Controller MD-NIM09 AHU Control Box Wall mounted Ceiling & oor 1.5~14kW

5 6

Cooling Only Mini Series

V-Ph-Hz

Capacity kW

Power input kW

Motor Type

Factory charging kg

Liquid pipe mm

Gas pipe mm

3m /h

dB(A)

mm

mm

kg

kg

EDVC-V72W/DVN1

7.2

1.64

4.39

4

1.4

Ф9.53

Ф15.9

3400

54

973×862×302

1025×910×410

58

63

EDVC-V92W/DVN1

9.2

2.06

4.47

5

1.4

Ф9.53

Ф15.9

3400

54

973×862×302

1025×910×410

58

63

EDVC-V145W/DVN1

14.5

3.57

4.06

8

2.6

Ф9.53

Ф15.9

5100

55

1053×865×523

1120×890×560

85

92

EDVC-V170W/DVN1

17

3.99

4.26

9

2.6

Ф9.53

Ф15.9

5100

55

1053×865×523

1120×890×560

85

92

°C

Model name

Power supply

1Cooling

Fan motor

DC

Quantity

Quantity

Airow rate

Net dimensions (W×H×D)

Net weight

Gross weight

EER

Type

1

Compressor

Connected indoor units

Total capacity

Maximum quantity

Operating temperature range

1

EDVC-V110W/DVN1

11

2.75

4

6

1.4

Ф9.53

Ф15.9

3400

54

973×862×302

1025×910×410

58

63

1-phase, 220V, 50/60Hz

45-130% of outdoor unit capacity

DC inverter

Cooling: -5 to 48

R410A

Refrigerant

Type

Pipe connections

Notes: 1. Indoor air temperature 27℃ (80.6℉) DB, 19℃ (66.2℉) WB; outdoor air temperature 35℃ (95℉) DB; equivalent refrigerant piping length 7.5m (24.6ft.) with zero level difference. 2. Sound pressure level is measured at a position 1m (3.28ft.) in front of the unit and 1.3m (4.26ft.) above the oor in a semi-anechoic chamber.

Specications

Controllers Lineup

Series

Series Capacity range

Four-way

cassette

Compact

four-way cassette

Low static

pressure duct

1.8-7.1kW

2.2-7.1kW

2.8~14kW

1.5~4.5kW

1.8-7.1kW

Appearance

One-way cassette

Two-way cassette

Series Capacity rangeAppearance

Wireless

remote

controller

Wired controller

Centralized

controller

& monitor

Network control

software & gateways

Accessories

RM05 RM12RM02

KJR-29B KJR-90D KJR-86C KJR-12B KJR-120C

CCM30 MD-CCM09 KJR-90BMD-CCM03

Modbus Gateway CCM-18A

LonWorks Gateway LonGW64

IMM Software & M-Interface

Data Converter CCM15

KNX Gateway MD-KNX

BACnet Gateway CCM08

Hotel Key Card Interface Module

MD-NIM05 3-Phase ProtectorDigital Power

Ammeter

Infrared Sensor Controller MD-NIM09

AHU Control Box

Wall mounted

Ceiling & oor

1.5~14kW

7.1~20kW

1.5~9kW

3.6~16kW

High static

pressure duct

Medium static

pressure duct

3. For a system with more than one IDU, to ensure even distribution of refrigerant, the capacity of each indoor unit should not exceed 8kW.

TRADEMASTER RESOURCES CORPORATIONLot E., Impex Compound, Alabang Zapote Road, Pamplona, Las Piñas City

Contact No.: (02) 865-2900 / 872-2222Visit our website at www.trademaster-philippine.com

Page 2: Everest Cooling Only Mini VRF Series Brochure · MD-NIM05 3-Phase Protector Digital Power Ammeter Infrared Sensor Controller MD-NIM09 AHU Control Box Wall mounted Ceiling & oor 1.5~14kW

1

2

3

4

5

6

2 3

Easier and safer installation thanks to a branch box that simplies piping work and the adoption of screw connection.

Both left and right pipe are connecting from outdoor unit to branch box is reserved, which greatly simplies eld

installation.

High Eciency

The DC inverter compressor adopts innovative

design and numerous high performance key parts

Compressor (Twin Rotary) structure

Highly Efficient DC Motor:

- Creative motor core design

- High density neodymium magnet

- Concentrated type stator

- Wider operating frequency range

Better balance and Extremely Low Vibration:

- Twin eccentric cams

- 2 balance weights

Highly Stable Moving Parts:

- Optimal material matching rollers and vanes

- Optimize compressor drive technology

- Highly robust bearings

- Compact structure

High EER Values

All DC Fan Motors

The system controls the speed of the fan motor according to the system pressure and system load achieving the

minimum power

Newly designed window type ns enlarge the heat exchange area and decrease air resistance, enhance heat

exchange performance and save more energy.

Hydrophilic ns and internally threaded copper pipes optimize heat exchange efciency.

Wide Operation Range

Mini VRF Series operates stably under extreme conditions, 48°C

ranging from minus 5°C to 48°C.

-5°C

Wide Application Range

COOLING MODE

Wide Capacity Range The outdoor units’ capacity range from 7.2kW to 17kW which is ideal for small ofces, villas, apartment and shops,

making it perfect for commercial and residential application.

14.5kW, 17kW7.2kW, 9.2kW, 11kW

Everest provides 9 types of VRF indoor units maximum meeting

varied customer requirements. It is widely applied in market,

hospital, ofce building, hotel, airport, etc..

Wide Range of Indoor Units

The lo

ngest

pip

ing le

ngth

is 7

0m

The

rst bra

nch

join

t to

the

fart

hest

ID

U is

20m

The ID

U to the n

eare

st

bra

nch

join

t is

15m

Leve

l diff

ere

nce

betw

een ID

U a

nd O

DU

is 3

0m

Leve

l diff

ere

nce

betw

een ID

Us

is 8

m

1 Total pipe length is equal to all the liquid pipe or all the gas pipe length.

2 When the total equivalent pipe length of liquid side plus gas side is more than 90m,

it needs to meet the specic conditions according to the installation part of the technical manual.

Permitted value(m)

Total piping length (Actual)

Longest piping (L)

Piping length

Level difference

Level difference between IDU~IDU

Level difference between IDU~ODU

Equivalent piping length (from the farthest IDU to the rst indoor branch joint)

7.2/9.2/11kW

100m

45m

50m

20m

30m

20m

8m

14.5/17kW

100m

60m

70m

20m

30m

20m

8m

Outdoor unit up

Outdoor unit down

Equivalent length

Actual length

Easy installation: No special area is required for outdoor units.

Easy transportaion: All outdoor units can be transported by elevator,

which greatly simplies installation and reduces time and labor.

The Mini VRF system's indoor and outdoor units are almost as easy to

install as residential airconditioning systems, making them ideal for

small ofces and shops.

Easy to transportEasy Installation

Moto

r sp

eed(R

PM

)

System pressure

DC inverter stepless adjustment

AC inverter multistep adjustment

200

400

600

800850

EER4.47

9.2kW

4.39

7.2kW

4.00

11kW

4.06

14.5kW

4.26

17kW

4.54.03.53.02.52.01.51.00.50.0

High Efficiency Heat Exchanger

difference