EURUS

VARIATION

Ergonomic,Clean and Professional

EURUS embodies our belief of bringing highly reliable Japan quality products to dentists in the world.

S1-Contour Chair-Chair Mount Over The Patient-Holder/Place/Rod-Unit Mounted LED Light

S3-Contour Chair-Pedestal Over The Patient-Holder/Place/Rod-Unit Mounted LED Light

S4-Folding Legrest Chair-Pedestal Over The Patient-Holder/Place/Rod-Unit Mounted LED Light

MADE IN JAPAN

SINCE 1921

Belmont Osaka Factory

Since 1921,Belmont provides high-quality products and service.

Highly trained workers handcraft the chair, unit and light.

ELECTRO HYDRAULIC

PATIENT WEIGHT CAPACITY

DURABILITY

200kg 165kg

CHAIR

Gear system-Noise,vibration and short life time

Belmont Hydraulic system-Smooth, quiet and long life time

NoiseVibration

Contour Chair Folding Legrest Chair

Life Time

Duration test

10 year x 240 days x 15 patient x 3 moves =108,000 moves

TWIN-AXIS HEADREST

POWER HEADREST

CHAIR

More Precise and Lighter Adjustment of Headrest- reduces burden on wrists and arm of the dentists

Control headrest position without hands

-helps female dentists to adjust it with less power

Adjustment angle EURUS: 7.5 degree Clesta2: 10.0 degree

PULLEURUS: 4.45 kgClesta2: 9.5 kg

UP & DOWN120mm stroke

Raise & ReclineFit to human head movement

PUSHEURUS: 0 kgClesta2: 3.0 kg

CONTOUR CHAIRDIMENSIONS

Unit: mmTolerance in dimensions: ±10%

2010

170

50

300

210

518

600

1055-1

615

73°

5-18°

420-

800

1380395180

Headrest: Electrohydraulic

Headrest: Manual

1975

170

50

300

103

0-15

95

73°

50° 8°

5-18°

420-

800

1380385

210

518

600

170° 235°

CHAIR

FOLDING LEGREST CHAIR

Unit: mmTolerance in dimensions: ±10%

2°18°

18°

110

0-13

65

450-

715

510 600615100 110

602

210

499

485

80°

720

1725

190

Dimensional drawing (standard values are provided)Headrest: Electrohydraulic

Headrest: Manual

2°18°

18°

109

0-13

60

450-

715

510 600580100 110

602

210

499

485 8

30°

180

720

1690

190

170°

235°

180

CHAIR

Dimensions

HOLDER & PLACE TYPE UNIT

Holder Type

- Separated holder can be adjusted for suitable position

- Holder,handle,touch panel and large table are within the reach

Place Type

-3 Roller guides for each handpiece

- Roller guide holds the weight of the hose- No need to look back when returning the handpiecies

ROD TYPE UNIT

Belmont Rod Type

-Long reach of 900 mm-Flexible holder

From side of the patient

From top of the patient

Micromotor Air turbine Scaler

Tension Adjustment-Tension can be adjusted to change each handpiece’s weight to reduce the burden.

Different tension setting for handpiece

PatientPatient UserUser

HighHeaterOFF

Switch

AAdultAdult

02:30

Manual

TOUCH PANEL UNIT

Timer indicationIndicates the status of the timer function in operation

Home screen

32 different user setting

Timer switchActivates the timer function

Patient memory switchSwitches the chair setting to match the patient

Cupfiller switchFills the cup with water

Bowl flush switchCleans the bowl

User memory switchSelects user-based operation memory

Water bottle indicatorIndicates a low water bottle level alarm

Bell switchPages an assistant, etc.

Function switchSets various operating conditions

Wireless foot controller indicatorIndicates remaining battery and pairing status

HP heater switchTurns on/off the HP heater

Dental light switchTurns on/off the dental light

Light switchSwitches light operation

Lock switchLocks the function of the touch panel and the stick switch

Water heater switchTurns on/off the water heater

Child

User A

4 positions 4 positions

4 positions

4 positions

4 positions

4 positions

4 positions

4 positions

User B

User C

User D

User E

User F

Adult Elderly

MICROMOTOR UNIT

Micro motor screen

Micromotor option specs

min-1

M4M2M1 M3

WA

User A

11 1:

5,000 5,000MaxMaxVa

AUTORev

Ncm 3.0

Memory tabCalls the rotation control memory

Slide mode switchSwitches slide mode of the foot controller

+/- switchIncreases/decreases rotation or power

Gear ratio switchSwitches the indication of gear ratio

Chair lock indicatorIssues chair lock status alarm

Torque control switchMicromotor setting of torque value/automatic reverse function

Menu call switchCalls various operation menu screens

Micromotor forward/reverse switchSwitches the rotation direction

Spray air switchTurns on/off spray air flow

Spray water switchTurns on/off spray water flow

Handpiece light switchTurns on/off the handpiece light

Torque

control

Auto reverse

Aurto forward

Setting range of maximum rotation (gear ratio 1:1)

100 1000 2000 5000 6000 10000 20000 30000 40000

Rotation range

Interval of settable maximum rotation

Every 1,000

Rotation range

Interval of settable maximum rotationEvery 1,000

Rotation range

Interval of settable maximum rotationEvery 1,000

High-speed rotation range

Interval of settable maximum rotation

Every 1,000

Low-speed rotation range

Interval of settable

maximum rotation

Every

100Every 500

High-speed rotation range

Interval of settable maximum rotation

Every 1,000

(Unit: min-1)

Interval of settable

maximum rotation

Every

100Every 500

Low-speed rotation range

NSK NBX

NSK NLX nano

NSK NLX plus

Bien air MCX

Bien air MX2

Brushless

Brushless

Brushless

Brushless

Brush

Type Max Torque

2.5Ncm

3.2Ncm

4.0Ncm

2.5Ncm

3.5Ncm

Model Picture

ScalingEndoPerio

WW

User A

5 8 /1 5 10

MaxMaxVa

SCALER UNIT

Scaler screen

Scaler option specs

Slide mode switchSwitches slide mode of the foot controller

Menu call switchCalls various operation menu screens

Spray water switchTurns on/off spray water flow

Handpiece light switchTurns on/off the handpiece light

Model Picture Scaling,Perio,Endo mode

EMS No pain

Satelec Xinetic

Satelec SP4055

Newtron

NSK Varios 170

Dentsply

Cavitron

Mode tab

Output

Maximum output(displayed only in Va mode)Touch bar graph

CUSPIDOR OPTION

VACUUM CLEAN SYSTEM

UNIT

Separator and Water disinfection system

Separator model Picture Air/Water Separation

Amalgam Separation

Amalgam Separation rate

Available combination withwater disinfection system

Dürr CS1

Dürr CAS1 WEK eco light

WEK

eco lightWEK

Metasys MST1Eco Light

Metasys MST1

Dürr Spittoon

Valve

95%

95%

Avairable Variation:S3 and S4

Available configuration matrix

Available configuration

Cleaner Bottle

Wat

er d

isin

fect

inon

syst

em ty

pe W/O water disinfection system

Metasys WEK LIGHT

Metasys WEK

W/O

Sep

arat

orSingle Vacuum

Dür

rC

AS

1(In

stal

led

)

Dür

r

CA

S1(

Pre

par

atio

n)

Sp

ittoo

n va

lve

Separator typeM

etas

ys M

ST1

eco

Met

asys

MS

T1

CS

1(In

stal

led

)

Dür

r

Dür

r

Dür

rS

pitt

oon

valv

e

CS

1(In

stal

led

)D

ürr

CS

1(P

rep

arat

ion)

Separator type

W/O

Sep

arat

or

Wat

er d

isin

fect

inon

syst

em ty

pe W/O water disinfection system

Metasys WEK LIGHT

Metasys WEK

Dür

rC

S1(

Pre

par

atio

n)

Dür

rC

AS

1(In

stal

led

)

Dür

rC

AS

1(P

rep

arat

ion)

Met

asys

MS

T1 e

co

Met

asys

MS

T1Twin Vacuum

Unit and chair surfaces : VirusesContacting blood and saliva directly or aerosol from patient,viruses acquire on the chair and unit surfaces .

STAY CLEAN AND SAFE

Dental unit water line : BacteriaBacteria forms on the walls of water line inside the dental treatment center only a few days.Legionella infection is one of the common health risks of dental unit.

Dental unit vacuum line : VirusesSuctioned blood, saliva and deposits stays on encrustationof vacuum line and create microbes.Risks of Viruses including HBV,HCV and HIV without treatment.

Inside Vacuum line

Blood

Saliva

Inside water line

LimescaleBiofilm

Belmont dental treatment center provides solutions against infection to stay clean and safe during procedure.

UP & DOWN

Normal mode

Light ON/OFF

Spray ON/OFF Micromotor Forward/Reverse

Composite safe mode

Raise & Recline

TOUCHLESS CONTROL

Light touchless sensorOn/Off without touch

Foot controlBlue switch can be customizedfor doctor’s choise and controlledby foot

Power headrestAdjust headrest without hands

Reduce infection risks by cotrolling device without hands.

STAY CLEAN AND SAFETOUCHLESS CONTROL

AUTOCLAVE 134

Holder cover

Holder sleeve

Detachable handle Autoclave process.

Autoclave detachable parts after the procedure.

Before sterilization, remove dirt on the surface and wash it under running water.Be sure to put it in a sterilization bag during the sterilization process. Do not perform dry processing exceeding the sterilization temperature.Autoclaved at a temperature of 134ºC for 3 minutes.

STAY CLEAN AND SAFE

CLEANING

Vacuum clean system

Water lineFlushing system

Water lineMetasys WEK or WEK light

Barrier film up to 0.15 mm is available

Light lenz cover can be cleaned as well

Metasys Green & Clean WK(WEK system)Water decontamination system approved by DVGWWhen : Constantly

Dürr Orotol plusVacuum line disinfectionWhen : Daily

Keep the surface and inside the unit clean with disinfection material showing below.Surface

Dürr FD366Surface disinfectionWhen:After each patient

Dürr FD360Leather cleaningWhen:After each patient

FlushingWater line cleaningWhen : Daily

STAY CLEAN AND SAFE

450-

715

UNIT UNIT

DIMENSIONS

LIGHT LIGHT

Technical Data

Dimensions

Optical performance ……… Standard irradiation distance: 650 mm In treatment mode Central illuminance: 3,000–28,000 lx Correlated color temperature: 5,000 K In Composite Safe mode (Compliant with ISO 9680: 2014 5.2.10) Central illuminance: 9,000 lx Correlated color temperature: 2,700 KIlluminance pattern ……… Pattern dimensions (length x width): 85 x 155 mm

75%50%

10%

144°

50°

989

160°

160°

5378

334

4

90°

90°

294

Unit:mm (tolerance in dimensions: ±10%)* The dimensions and specifications are subject to change without notice.