通过ETHERNET建立SIMATIC NET OPC 服务器与PLC 的S7...
Transcript of 通过ETHERNET建立SIMATIC NET OPC 服务器与PLC 的S7...
-
ETHERNET SIMATIC NET OPC PLC S7 Building Up The S7 Connection Between SIMATIC NET OPC Server and PLC Via
ETHERNET
Getting-started Edition (2005 5 )
-
SIMATIC NET ETHERNET OPC
ETHERNET OPC S7 PLC S7
WINCC OPC WinCC ETHERNET OPC S7
S7 PLC PLC
OPC S7 WinCC
Key Words Ethernet; OPC Server; S7 connection; WinCC
A&D Service & Support
Page 2-31
-
ETHERNETSIMATIC NET OPC PLC S7 ................................................1
.................................................................................................................4
1. SIMATIC NET PC ............................................................................................4
2. ETHERNETPC ..........................................................................................4
3. ETHERNETOPC............................................................................................5
4. PC .................................................................................................5
5. SIMATIC NET...................................................................6
ETHERNETOPC S7 PLC S7 PC .....................6
1. ..............................................................................................6
2. OPCPLC S7 ............................................................................6
WINCCOPC.......................................................................................... 26
PCOPC Server .................................................... 29
........................................................................................................... 31
A&D Service & Support
Page 3-31
-
1. SIMATIC NET PC
SIMATIC NET
PLC
SIMATIC NET
AS-I
PROFIBUS
PROFIBUS-PA
SIMATIC NET
PLC LAN CP
2. ETHERNET PC
PC SIMATIC NET V6.0 Advanced PC Configuration
PC PC
COM L S7 NCM PC V5.1+SP2 STEP 7 V5.1+SP2 PC
SIMATIC S7
NCM PCSTEP 7
NCM PC:
NCM PC SIMATIC NET PC STEP 7
NCM PC STEP 7 S7
STEP 7:
STEP 7 NCM PC STEP 7
PC
A&D Service & Support
Page 4-31
-
3. ETHERNET OPC
OPC SIMATIC NET
OPC(OLE For Process Control OLE)OPC
OPC
OPC
2.05
1.02
/
C++
VB OCX
XML DA
OPC Ethernet:
S7
S5 /
PROFInet
4. PC
SIMATIC NET PC SOFTWARE V6.0 SP5
NCM PC V5.1+SP2
STEP 7 V5.1+SP2
SOFTNET-IE S7 (CP1612 )
S7-1613 (CP1613)
CP1613 10/100
PC SIMATIC NET WINDOWS2000;
WINDOWSXP
A&D Service & Support
Page 5-31
-
http://support.automation.siemens.com/CN/view/zh/9859007
SIMATIC NET
5. SIMATIC NET
http://support.automation.siemens.com/CN/view/zh/15227599 SIMATIC NET
ETHERNET OPC S7 PLC S7 PC
1.
SIMATIC NET PC SOFTWARE V6.2 SP1
STEP 7 V5.3 SP1
Softnet S7 IE
S7 300 CPU315-2DPCP343-1(6GK7 343-1EX20-0XE0)
TCP/IP
2. OPC PLC S7
PC
SIMATIC NET PC Station Configurator
(Taskbar) Station Configuration Editor
1: Station Configurator 2
A&D Service & Support
Page 6-31
http://support.automation.siemens.com/WW/view/en/9859007http://support.automation.siemens.com/WW/view/en/15227599
-
1) Station Configuration Editor
2Station Configuration Editor
2) Add OPC
Server OK
3 OPC Server
A&D Service & Support
Page 7-31
-
3) IE General
4 IE General
IE General Network Properties
5
4)
Network Properties WINDOWS
IP 6 7 8
A&D Service & Support
Page 8-31
-
6:
7
A&D Service & Support
Page 9-31
-
8
5) PC Station
Station Name PC ethernetopcOK
PC
9 PC
Station Name PC
A&D Service & Support
Page 10-31
-
Configuration Console
1) Configuration Console PC
PC
2) PC start simatic simatic
net Configuration console PG mode
Configuration mode,Index 3 8
10 Configuration Console
Simatic Net V6.1 V6.0
Mode of the module PG Configured mode
Index Station Configuration Editor
A&D Service & Support
Page 11-31
-
3) Access Points S7ONLINE PC internal(local)
PC
11PC Station Access Point
STEP 7 PC Station
1) SIMATIC Manager File New s7ethernetopc
Insert Station Simatic Pc Station PC
PC Station SIMATIC PC Station(1) Station Configuration
Editor Station Name ethernetopc
Configuration PC Station
A&D Service & Support
Page 12-31
-
12 STEP 7 Simatic PC Station
A&D Service & Support
Page 13-31
-
2) Simatic net
Station Configuration Editor PC
13 PC Station
3)
IE General Properties ,
IP IP
IP 7 IP New ethernet
A&D Service & Support
Page 14-31
-
14
A&D Service & Support
Page 15-31
-
4) PC
15
5) Configure Network NetPro
16Configure Network
A&D Service & Support
Page 16-31
-
6) NetPro OPC Server
Insert>New Connection
17
7) STEP 7 PLC PLC
CP343-1 or CP443-1Insert New
Connection
Insert New
ConnectionUnspecified
S7 connection OK
18NetPro
A&D Service & Support
Page 17-31
-
8) S7 PLC (CP343-1 or
CP443-1)IP 19 PartnerAddress
Address Details
Rock/Slot S7 300 PLC
02 S7 400 CPU OK
Slot CPU
19S7
A&D Service & Support
Page 18-31
-
9) S7
Network>Save and Compile No error
Warning
error Message
PC Station
20
A&D Service & Support
Page 19-31
-
1) PC NetPro PC
PC OK
21
A&D Service & Support
Page 20-31
-
2) Station Configuration Editor
OPC Server Conn
Simatic Net V6.1 V6.0
22 PC Station
A&D Service & Support
Page 21-31
-
OPC Scout
OPC Scout Simatic Net PC Station
OPC Server PLC
1) OPC Scout,Start>SIMATIC>SIMATICNet>OPC Scout 21 OPC
SimaticNetADD Group
OPC_ETHERNET OK
23 OPC Scout OPC_ETHERNET
A&D Service & Support
Page 22-31
-
2) OPC_ETHERNETOPC Navigator
Configuration Console S7 PC
Station NetPro S7 connection_1
objects tree PLC CPU
DB
24Objects in the OPC Navigator
3) PLC DB
DB DB New
DefinitionDefine New Item
DatatypeAddressNo.Value No.Value
OK
A&D Service & Support
Page 23-31
-
25
4) Define New Item OPC Navigator
OPC-Navigator OK
OPC Server.
26 OPC Server
A&D Service & Support
Page 24-31
-
5) Item OPC Scout Quality
good OPC Server PLC S7
27OPC Scout OPC Server
ValueWrite Value(s) to the Item(s)
28
A&D Service & Support
Page 25-31
-
WINCC OPC
WINCC OPC channel OPC Server
OPC
29
OPC.CHN 30 OPC
30 OPC
A&D Service & Support
Page 26-31
-
OPC OPC Server,
SIMATIC NET OPC
31
31
OPC ServerOPC.SimaticNET
32 OPC
A&D Service & Support
Page 27-31
-
33
34
A&D Service & Support
Page 28-31
-
OPC Scout WINCC
35 OPC
PC OPC Server
1. PC Station Cannot reach station
manager
1) Set PG/PC Interface Configuration Console S7 Online Access Points
PC InternalLocal
2) PC STEP 7 NCM PC PC
3) PC CP OPC Application STEP 7 NCM PC
http://support.automation.siemens.com/CN/view/zh/12033912
2 OPC Scout OPC-Navigator
Simatic Net OPC OPC Scout OPC Navigator OPC
OPC
New
DefinitionDefine New Item OPC
A&D Service & Support
Page 29-31
http://www.ad.siemens.com.cn/service
-
Server OPC
OPC
http://support.automation.siemens.com/CN/view/zh/8763769
2.
www.ad.siemens.com.cn/service ,
Compatibility list
27
A&D Service & Support
Page 30-31
http://support.automation.siemens.com/CN/view/zh/8763769http://www.ad.siemens.com.cn/service
-
AS http://www.ad.siemens.com.cn/Service/http://www.ad.siemens.com.cn/Service/recommend.aspAShttp://support.automation.siemens.com/CN/view/zh/10805055/133000 AShttp://support.automation.siemens.com/CN/view/zh/10805055/133400 AShttp://www.ad.siemens.com.cn/service/answer/category.asp?cid=1027 HMI http://www.ad.siemens.com.cn/Service/http://www.ad.siemens.com.cn/Service/recommend.aspHMIhttp://support.automation.siemens.com/CN/view/zh/10805548/133000 HMIhttp://support.automation.siemens.com/CN/view/zh/10805548/133400 WinCChttp://www.ad.siemens.com.cn/service/answer/category.asp?cid=1032 NET http://www.ad.siemens.com.cn/Service/http://www.ad.siemens.com.cn/Service/recommend.aspNethttp://support.automation.siemens.com/CN/view/zh/10805868/133000 Nethttp://support.automation.siemens.com/CN/view/zh/10805868/133400 Nethttp://www.ad.siemens.com.cn/service/answer/category.asp?cid=1031
A&D Service & Support
Page 31-31
http://www.ad.siemens.com.cn/Service/http://www.ad.siemens.com.cn/Service/recommend.asphttp://support.automation.siemens.com/CN/view/zh/10805055/133000http://support.automation.siemens.com/CN/view/zh/10805055/133400http://www.ad.siemens.com.cn/service/answer/category.asp?cid=1027http://www.ad.siemens.com.cn/Service/http://www.ad.siemens.com.cn/Service/recommend.asphttp://support.automation.siemens.com/CN/view/zh/10805548/133000http://support.automation.siemens.com/CN/view/zh/10805548/133400http://www.ad.siemens.com.cn/service/answer/category.asp?cid=1032http://www.ad.siemens.com.cn/Service/http://www.ad.siemens.com.cn/Service/recommend.asphttp://support.automation.siemens.com/CN/view/zh/10805868/133000http://support.automation.siemens.com/CN/view/zh/10805868/133400http://www.ad.siemens.com.cn/service/answer/category.asp?cid=1031%20
1. SIMATIC NET PC 2. ETHERNETPC3. ETHERNETOPC4. PC5. SIMATIC NET
ETHERNETOPC S7 PLC S7PC1. 2. OPCPLC S7
WINCCOPC PCOPC Server