7/16/2019 Ethernet Temperature & Humidity Data Logger for remote monitoring
http://slidepdf.com/reader/full/ethernet-temperature-humidity-data-logger-for-remote-monitoring-568bd0d5637dd 1/7
14 May 2015
Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55email:[email protected]
www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India
Ethernet Temperature & Humidity Data Logger for remote monitoring
Features
>> Measure and Record 2 Temperature Readings Using External Sensors
>> -40°C to 110°C Temperature Recording Range with ±0.3°C Temperature Accuracy
>> Configure, Setup and Manage Data Loggers over an Internet Connection and Browser
>> Free WebStorage Service, WebViewer and Current Readings Monitor Software Included
>>Phone call, Email & SMS alert system (optional)
>> Stores up to 8,000 Sets of Recorded Readings onto Internal Non-Volatile Memory
>> User-Configurable Sampling Rate: 1 Second to 1 Hour
>> Email Alarm Notifications and Optional External Contact Terminal for Electromagnetic Contactor
>> AC Powered with Battery Backup for Power Failures and Emergency Use Only
>> Automatic Sending of Measured Readings via FTP or E-mail
Specifications
TR-701NW /701AW
TR-702NW / 702AW TR-702NW-H / 702AW-H
Temperature/HumiditySensor (External)
TR-0106 THA-3151 HHA-3151(High-Precision Type)
Thermistor ThermistorPolymerResistance
PlatinumResistance
ElectrostaticCapacitance
MeasurementChannels
Temperature2ch
Temperature1ch
Humidity1ch
Temperature1ch
Humidity 1ch
Measurement Units °C, °F °C, °F %RH °C, °F %RH
Measurement Range
-40 to110°C(SuppliedSensor)-60 to155°C(OptionalSensor:FluoropolymerCoated Type)
0 to 55°C10 to95%RH
-30 to 80°C 0 to 99%RH
Accuracy
Avg. ±0.3°C [-20 to 80°C]
Avg. ±0.5°C [-40 to -20 / 80 to110°C]
±0.5°C±5%RH [at25°C,50%RH]
±0.3°C [0 to50°C]±0.5°C [at allothertemperatures]
±2.5%RH [at 25°C, 10to 85%RH]±4.0%RH [at 25°C, 0to 10%RH or 85 to99%RH]
At temperatures otherthan 25°C and ≥ 0°C,
add ±0.1%RH perdegree of differencefrom 25.Humidity Hysteresis:±1.5%RH or lower *1
Measurement
Resolution 0.1°C 0.1°C 1%RH 0.1°C 0.1%RH
ResponsivenessThermal TimeConstant:
Approx. 75sec.
Response Time (90%): Approx. 7min.
ResponseTime (90%):
Approx. 7min.
Response Time(90%): Approx. 20sec.
7/16/2019 Ethernet Temperature & Humidity Data Logger for remote monitoring
http://slidepdf.com/reader/full/ethernet-temperature-humidity-data-logger-for-remote-monitoring-568bd0d5637dd 2/7
14 May 2015
Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55email:[email protected]
www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India
Response Time(90%): Approx.190sec.
Logging Capacity8,000 data sets (One data set consists of readings for all channels in that type ofunit.)
Recording IntervalSelect from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60
min.Recording Mode Endless (Overwrite oldest data when capacity is full)
LCD Display Items Measurements (alternating display), Power Warning Mark, etc.
CommunicationInterfaces
TR-701NW / 702NW: Wired LANRJ45 Connector 100 Base-TX / 10 Base-T AutoMDI / MDI-XTR-701AW / 702AW: Wireless LANInternal wireless LAN antenna IEEE 802.11b/g
WEP(64bit/128bit) / WPA-TKIP/WPA2-AES
USB Communication (For Setup)
External AlarmTerminal
<Output Terminal: Photo Mos Relay Output>Voltage when OFF: AC/DC less than 50VCurrent when ON: less than 0.1AResistance when ON: about 35Ω
CommunicationsProtocol
HTTP, SMTP (POP before SMTP, SMTP-AUTH <LOGIN>), FTP, SNTP, DHCP,DNS
PowerMain Power: AC Adaptor (AD-0638 or AD-0638-C) / Backup Power: Coin TypeLithium Battery (CR-2032) *2
Data Backup *3 Approx. 3 months (backup battery CR-2032 only without AC adaptor)
Dimensions H 55 mm x W 78 mm x D 37 mm
WeightTR-701NW / 702NW / 702NW-H : approx. 82 gTR-701AW / 702AW / 702AW-H : approx. 80 g(including battery, excluding sensor)
OperatingEnvironment
Temperature: -10 to 60°CHumidity: 90 %RH or less (no condensation)
Accessories
Temperature Sensor (TR-0106) x 2
Temperature/HumiditySensor (THA-3151) x 1
High PrecisionTemperature/HumiditySensor (HHA-3151) x1
USB Communication Cable (US-15C), LAN Cable (LN-20W: For TR-701NW /702NW only), AC Adaptor (AD-0638 or AD-0638-C), Coin Type Lithium Battery(CR-2032), Software (CD-ROM), Manual Set (Warranty Included) x 1
Supported Browsers
<Desktop Browser>Internet Explorer (6.0 or later), Firefox (15.0 or later), Chrome (22.0 or later),Safari (6.0 or later)<Mobile Browser>Safari (iOS), Chrome (iOS, Android), Firefox (Android)
*1: When used in environments where temperature and humidity are over the values of 50°C 75%, 60°C50%, 70°C 35%, and 80°C 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH. Under
certain circumstances, it may take some time to return to normal measurement capability.*2: The supplied lithium battery is for data backup during power failure and for emergency use only. Notethat network communication cannot occur when using only the battery.
*3: Battery life varies depending upon the ambient temperature and the battery performance. All estimatesare based on operations carried out with a new battery and are in no way a guarantee of actual batterylife.
Use via Network Connection
The TR-700W Series Loggers allow you to make device settings, monitor current readings, gather recorded dataand an array of other functions via LAN or Internet connection.The USB connection also allows for settings including wired LAN and wireless LAN settings to be made directly
from a PC.
7/16/2019 Ethernet Temperature & Humidity Data Logger for remote monitoring
http://slidepdf.com/reader/full/ethernet-temperature-humidity-data-logger-for-remote-monitoring-568bd0d5637dd 3/7
14 May 2015
Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55email:[email protected]
www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India
Various Monitoring Functions
Using "WebViewer": The TR-700W Series WebViewer application enables the viewing of data graphs in your browser.
In the browser you can not only view graphs and current readings, but also settings information for the target TR-700W Series device.
Using "T&D WebStorage Service": As long as you have access to the Internet, our "T&D WebStorage Service" is available; thus bringing you"anytime anywhere" access to your recorded data for monitoring, saving, analyzing, printing, and so on.This service also allows for the viewing, sharing and usage of data by multiple parties across distances at thesame time, thus providing increased management efficiency.
7/16/2019 Ethernet Temperature & Humidity Data Logger for remote monitoring
http://slidepdf.com/reader/full/ethernet-temperature-humidity-data-logger-for-remote-monitoring-568bd0d5637dd 4/7
14 May 2015
Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55email:[email protected]
www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India
Via "Current Readings Monitor": The "Current Readings Monitor" application included in the software package allows not only for the managementof current readings, but also provides a way to manage all devices registered on the same network.
Via Mobile Device: Both "WebViewer" and "T&D WebStorage Service" can be used with mobile devices such as smart phones and
tablets, enabling easier access to data anytime, anywhere.
7/16/2019 Ethernet Temperature & Humidity Data Logger for remote monitoring
http://slidepdf.com/reader/full/ethernet-temperature-humidity-data-logger-for-remote-monitoring-568bd0d5637dd 5/7
14 May 2015
Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55email:[email protected]
www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India
Efficient Warning Monitoring Functions
It is possible to have warning report e-mails sent when user set conditions have been met.Warning report mails can be sent when an upper and/or lower limits have been exceeded, when a sensor errorhas occurred or when there has been a recovery from one of the set warning conditions.
Also, by connecting a warning device to the external contact output terminal, it is possible to receive notificationof a warning by buzzer, siren, lamp, or other electromagnetic contactor. It is also possible to select whether or notto have the external warning coupled with a warning report mail.
Auto-Sending of Measurements
Using Device Settings for TR-700W Series Data Logger: By making settings in the device it is possible to automatically have Recorded Data and/or Current Readings sentperiodically via FTP or e-mail without the need for PC.
Using the "Current Readings Monitor": If a server is not available, it is possible to use the "Current Readings Monitor" application to have recorded dataautomatically saved.
7/16/2019 Ethernet Temperature & Humidity Data Logger for remote monitoring
http://slidepdf.com/reader/full/ethernet-temperature-humidity-data-logger-for-remote-monitoring-568bd0d5637dd 6/7
14 May 2015
Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55email:[email protected]
www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India
High-Performance User Friendly Graph Software Available
Our newly designed software "T&D Graph" gives you greater management and analyzing power for dealing withthe recorded data (TRZ format) collected from TR-700W Series loggers."T&D Graph" allows you to read larger numbers of recorded data files (TRZ format) into the same graph, mergedata, view and save data various ways. It can be downloaded free of charge at theT&D Website.
This versatile graph tool not only allows the user to directly access data stored in the WebStorage Service, butthe user can also specify conditions such as time period for which data to view and analyze.It is also possible to sample and filter data, add memos and write comments directly on the graph, as well as,save data to CSV Format for use with common spreadsheet software.
7/16/2019 Ethernet Temperature & Humidity Data Logger for remote monitoring
http://slidepdf.com/reader/full/ethernet-temperature-humidity-data-logger-for-remote-monitoring-568bd0d5637dd 7/7
14 May 2015
Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55email:sales uae@vackerglobal com
www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India
All images and data above are copyrighted to the manufacturer T&D corporation, Japan
Videos:
Functioning demo : http://bit.ly/1jZAJRe
Remote monitoring software demo : http://bit.ly/1srWvh8