ETERNUS Configuration Guide
-
Upload
mahmoud-ahmed -
Category
Documents
-
view
241 -
download
0
Transcript of ETERNUS Configuration Guide
-
7/24/2019 ETERNUS Configuration Guide
1/42
ETERNUS
[Specification]
(1) ETERNUS DX60 S2 1(2) ETERNUS DX80 S2 2
(3) ETERNUS DX90 S2 3(4) Supported RAID 4
[Outline]
(1) View 5(2) Product Diagrams 7
[System configuration tree diagram]
(1) ETERNUS DX60 S2 (Dual-controller type) 9(2) ETERNUS DX60 S2 (Single-controller type) 11(3) ETERNUS DX80 S2 (Dual-controller type) 14(4) ETERNUS DX80 S2 (Single-controller type) 17(5) ETERNUS DX90 S2 (Dual-controller type) 20(6) ETERNUS DX90 S2 (Single-controller type) 23
(7) Options 26(8) Cables 39(9) Rack 40
(10) ETERNUS Multipath Driver 41
Product ID/Descriptions Meaning of each circle ()Each product has "Product Description", "ProductID" => Only one selection can be madeand "Brief Remarks" as follows. =>Multiple selections are possible.
(There may be some restriction)Ex) Product name
Drive enclosure
- Rackmount type 2U
ETLDE2AU
Product ID Brief Remarks
Copyright 2013 FUJITSU LIMITED
System Configuration Guide February 2013, 6th editionCONTENTS
ETERNUS DX 60 S2, DX80 S2, DX90 S2 Disk Storage Systems
Se
lectonly
Con
current
connections
perm
itted
-
7/24/2019 ETERNUS Configuration Guide
2/42
SINGLE
CONTROLLER
DUAL
CONTROLLER
SINGLE
CONTROLLER
DUAL
CONTROLLER
Physical capacity *2
Logical capacity *3
1 2 1 2
2 4 2 4
1GB 2GB 1GB 2GB
Capacity (rotation speed)
Drive interface
Capacity (rotation speed)
Drive interface
Capacity
Drive interfaceCapacity (rotation speed)
Drive interface
Capacity (rotation speed)
Drive interface
Capacity
Drive interface
Controller Enclosure
Drive Enclosure
Controller Enclosure
Drive Enclosure
Voltage
Phase
Frequency
Controller Enclosure
Drive Enclosure
Controller Enclosure
Drive Enclosure
Temperature
Humidity
*1: Storage capacity depends on which HDDs are mounted.
*2: The physical capacity value was calculated as 1 KByte = 1,000 Bytes.
*3: The logical capacity value was calculated as 1 KByte = 1,024 Bytes when formatted as RAID5.
User area capacity differs depending on the environment.
ETERNUS DX60 S2, DX80 S2, DX90 S2
Number of controllers
Host Interfaces
Fibre Channel (Max. 4Gbit/s)
iSCSI (Max. 1Gbit/s)
SAS (Max. 3Gbit/s)
Number of host interfaces
Number of connectable hosts 32, 64 (2, 4 for SAS connection)
(1) ETERNUS DX60 S2 Speci fic ation
Product name ETERNUS DX60 S2
2.5" MODEL 3.5" MODEL
Supported RAID levels 0, 1, 1+0, 5, 5+0, 6
Storage Capacity *1 Max. 24.0TB Max. 72.0TB
Max. 17.8TB Max. 53.4TB
Cache memory capacity
Number of drives 2 - 24
Disk Drives
3.5"
SAS disk drive
3.5" nearline
SAS disk drive
3.5" SSD -
-2.5"
SAS disk drive
2.5" SSD -
-
-
-
-
-
900GB, 600GB,450GB,300GB(10,000rpm)
SAS (Max. 3Gbit/s)
600GB, 450GB, 300GB (15,000rpm)
SAS (Max. 3Gbit/s)
3TB, 2TB, 1TB (7,200rpm)
SAS (Max. 3Gbit/s)
-
35 kg
Power
AC 100 - 120 V / AC 200 - 240 V
Single
50 Hz / 60 Hz
Dimensions (W x D x H)- 483 650 88 mm (2U)
Maximum W eight
(per one Enclosure) - 35 kg
-
Environmental Conditions 10 - 40 C (Operating), 0 - 50 C (Non-operating)
20 - 80 %RH (Operating), 8 - 80 %RH (Non-operating)
483 650 88 mm (2U) 483 650 88 mm (2U)
35 kg
440W (450VA) [1,590kJ/h]
370W (380VA) [1,340kJ/h]
430W (440VA) [1,550kJ/h]
- 370W (380VA) [1,340kJ/h]
2.5" nearline
SAS disk drive
-
-
1TB (7,200rpm)
SAS (Max. 3Gbit/s)
Maximum Power
Consumption
[Maximum Heat
Generation]
AC100-120V
AC200-240V
510W (520VA) [1,840kJ/h]
-
500W (510VA) [1,800kJ/h]
1
-
7/24/2019 ETERNUS Configuration Guide
3/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
SINGLE
CONTROLLER
DUAL
CONTROLLER
SINGLE
CONTROLLER
DUAL
CONTROLLER
Physical capacity *3
Logical capacity *4
1 2 1 2
2 / 4 4 / 8 2 / 4 4 / 8
2GB 4GB 2GB 4GB
Capacity (rotation speed)
Drive interface
Capacity (rotation speed)Drive interface
Capacity
Drive interface
Capacity (rotation speed)
Drive interface
Capacity (rotation speed)
Drive interface
Capacity
Drive interface
Controller Enclosure
Drive Enclosure
Controller Enclosure
Drive Enclosure
Voltage
Phase
Frequency
Controller Enclosure
Drive Enclosure
Maximum configuration
Controller Enclosure
Drive Enclosure
Maximum configuration
Temperature
Humidity
*1: 2.5" base unit items are based on configuration with 2.5" drive enclosures only.
*2: Storage capacity depends on which HDDs are mounted.
*3: The physical capacity value was calculated as 1 KByte = 1,000 Bytes.*4: The logical capacity value was calculated as 1 KByte = 1,024 Bytes when formatted as RAID5.
User area capacity differs depending on the environment.
*5: Mixtures of 2.5" and 3.5" drives are supported by adding both 2.5" and 3.5" drive enclosures.
800GB, 400GB, 200GB, 100GB
Single
50 Hz / 60 Hz
AC 100 - 120 V / AC 200 - 240 V
35 kg 35 kg
Dimensions (W x D x H)
10 40 C (Operating), 0 - 50 C (Non-operating)
20 - 80 %RH (Operating), 8 - 80 %RH (Non-operating)
2-120
Environmental Conditions
600GB, 450GB, 300GB (15,000rpm)
Power
2.5"
SAS disk drive
Disk Drives
3.5" SSD
3.5"
SAS disk drive
2.5" SSD
SAS (Max. 6Gbit/s)
Number of drives
SAS (Max. 6Gbit/s)
SAS (Max. 6Gbit/s)
3.5" nearlineSAS disk drive
482 645 88 mm (2U) 482 670 88 mm (2U)
482 540 88 mm (2U) 482 555 88 mm (2U)
Host Interfaces
900GB, 600GB,450GB,300GB(10,000rpm)
SAS (Max. 6Gbit/s)
Number of host interfaces
2.5" MODEL *1
800GB, 400GB, 200GB, 100GB
SAS (Max. 6Gbit/s)
3TB, 2TB, 1TB (7,200rpm)
3.5" MODEL
Number of connectable hosts
ETERNUS DX80 S2
Supported RAID levels
Maximum
Power
Consumption
[Maximum
Heat
Generation]
AC100 - 120V
AC200 - 240V
630W (640VA) [2,300kJ/h]
570W (580VA) [2,100kJ/h]
620W (630VA) [2,300kJ/h]
550W (560VA) [2,000kJ/h]
5,570W (5,670VA) [20,300kJ/h]
630W (640VA) [2,300kJ/h] 610W (620VA) [2,200kJ/h]
570W (580VA) [2,100kJ/h] 550W (560VA) [2,000kJ/h]
5,560W (5,660VA) [20,200kJ/h]
Maximum W eight
(per one Enclosure) 35 kg 35 kg
Storage Capacity *2
iSCSI (Max. 1Gbit/s)
Max. 1,024
iSCSI (Max. 10Gbit/s)
SAS (Max. 6Gbit/s)
FCoE (Max. 10Gbit/s)
2.5" nearline
SAS disk drive
1TB (7,200rpm)
SAS (Max. 6Gbit/s)
(2) ETERNUS DX80 S2 Speci fic ation
0, 1, 1+0, 5, 5+0, 6
Fibre Channel (Max. 16Gbit/s)
Number of controllers
Cache memory capacity
Product name
Max. 360.0TB
Max. 267.0TB
2
-
7/24/2019 ETERNUS Configuration Guide
4/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
SINGLE
CONTROLLER
DUAL
CONTROLLER
SINGLE
CONTROLLER
DUAL
CONTROLLER
Physical capacity *3
Logical capacity *4 1 2 1 2
2 / 4 4 / 8 2 / 4 4 / 8
4GB 8GB 4GB 8GB
Capacity (rotation speed)
Drive interface
Capacity (rotation speed)
Drive interfaceCapacity
Drive interface
Capacity (rotation speed)
Drive interface
Capacity (rotation speed)
Drive interface
Capacity
Drive interface
Controller Enclosure
Drive Enclosure
Controller Enclosure
Drive Enclosure
VoltagePhase
Frequency
Controller Enclosure
Drive Enclosure
Maximum configuration
Controller Enclosure
Drive Enclosure
Maximum configuration
Temperature
Humidity
*1: 2.5" base unit items are based on configuration with 2.5" drive enclosures only.
*2: Storage capacity depends on which HDDs are mounted.
*3: The physical capacity value was calculated as 1 KByte = 1,000 Bytes.
*4: The logical capacity value was calculated as 1 KByte = 1,024 Bytes when formatted as RAID5.User area capacity differs depending on the environment.
*5: Mixtures of 2.5" and 3.5" drives are supported by adding both 2.5" and 3.5" drive enclosures.
50 Hz / 60 Hz
SAS (Max. 6Gbit/s)
900GB, 600GB,450GB,300GB(10,000rpm)
SAS (Max. 6Gbit/s)
482 555 88 mm(2U)
2.5"
SAS disk drive
3.5" SSD
Power
Dimensions (W x D x H)
2.5" SSDSAS (Max. 6Gbit/s)
AC 100 - 120 V / AC 200 - 240 V
Single
35 kg
35 kg 35 kg
Maximum W eight
(per one Enclosure)
35 kg
482 645 88 mm(2U)
482 540 88 mm(2U)
482 670 88 mm(2U)
Disk Drives
3.5"
SAS disk drive
2.5" nearline
SAS disk drive
600GB, 450GB, 300GB (15,000rpm)
Cache memory capacity
Number of connectable hosts
SAS (Max. 6Gbit/s)
2.5" MODEL *1 3.5" MODEL
iSCSI (Max. 10Gbit/s)
ETERNUS DX90 S2
Max. 360.0TB
Max. 267.0TB
iSCSI (Max. 1Gbit/s)
Number of controllers
Fibre Channel (Max. 16Gbit/s)
Number of host interfaces
Host Interfaces
Max. 1,024
(3) ETERNUS DX90 S2 Speci fic ation
SAS (Max. 6Gbit/s)
FCoE (Max. 10Gbit/s)
Storage Capacity *2
0, 1, 1+0, 5, 5+0, 6Supported RAID levels
Product name
800GB, 400GB, 200GB, 100GB
Environmental Conditions20 - 80 %RH (Operating), 8 - 80 %RH (Non-operating)
2-240 2-120
10 - 40 C (Operating), 0 - 50 C (Non-operating)
Maximum
Power
Consumption
[Maximum
Heat
Generation]
AC100 - 120V
630W (640VA) [2,300kJ/h] 620W (630VA) [2,300kJ/h]
570W (580VA) [2,100kJ/h] 550W (560VA) [2,000kJ/h]
5,760W (5,860VA) [21,200kJ/h]
AC200 - 240V
630W (640VA) [2,300kJ/h] 610W (620VA) [2,200kJ/h]
570W (580VA) [2,100kJ/h] 550W (560VA) [2,000kJ/h]
5,760W (5,860VA) [21,200kJ/h]
3TB, 2TB, 1TB (7,200rpm)
SAS (Max. 6Gbit/s)800GB, 400GB, 200GB, 100GB
3.5" nearline
SAS disk drive
Number of drives
1TB (7,200rpm)
SAS (Max. 6Gbit/s)
3
-
7/24/2019 ETERNUS Configuration Guide
5/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
The ETERNUS DX60 S2/DX80 S2/DX90 S2 support the following RAID levels.
Use of RAID0 is not recommended because it is not redundant.For RAID0 configurations, data may be lost due to disk drive failure.
Recommended number disk drives
RAID0 2 - 16 2 - 16 *1
RAID1 2 2 2 (1Data + 1Mirror)RAID1+0 4 - 24 4 - 32 4 (2Data + 2Mirror)
6 (3Data + 3Mirror)8 (4Data + 4Mirror)
10 (5Data + 5Mirror)RAID5 3 - 16 3 - 16 3 (2Data + 1Parity)
4 (3Data + 1Parity)5 (4Data + 1Parity)6 (5Data + 1Parity)
RAID5+0 (3 - 12) x 2 (3 - 16) x 2 3 (2Data + 1Parity) x 24 (3Data + 1Parity) x 25 (4Data + 1Parity) x 26 (5Data + 1Parity) x 2
RAID6 5 - 16 5 - 16 5 (3Data + 2Parity)6 (4Data + 2Parity)7 (5Data + 2Parity)
*1: Use of RAID0 is not recommended because it is not redundant.
ETERNUS DX80 S2ETERNUS DX90 S2
Supported number disk drives
RAID level
(4) Suppo rted RAID
ETERNUS DX60 S2
4
-
7/24/2019 ETERNUS Configuration Guide
6/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
(1) ETERNUS DX60 S2 View
- Base unit
Front Cover
Controller (Standard)(Additional Controller (Option))
Host Interface (Standard)
AC power cable (200V)(Standard)
LAN port
Drive interface (OUT) portPower Supply Unit (Standard)
Base unit rear view
- Drive Enclosure
Front Cover
Drive interface (OUT) portDrive interface (IN) port
AC power cable (200V)(Standard)
Power Supply Unit (Standard)
Drive Enclosure r ear view
Drive Enclosure front view(3.5" type)
ETERNUS DX60 S2 View
Base unit front view Base unit front view(3.5" type) (2.5" type)
5
-
7/24/2019 ETERNUS Configuration Guide
7/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
(2) ETERNUS DX80 S2, DX90 S2 View
- Base unit (Controller Enclosure)
3.5" disk 2.5" disk
Controller (Standard)(Additional Controller (Option))
Host Interface (Standard)
AC power cable (200V)(Standard)
LAN port
Drive interface (OUT) portPower Supply Unit (Standard)
Base unit rear view
- Drive Enclosure
3.5" disk 2.5" disk
Drive interface (OUT) portDrive interface (IN) port
AC power cable (200V)(Standard)
Power Supply Unit (Standard)
Drive Enclosure r ear view
(3.5" type) (2.5" type)
ETERNUS DX80 S2, DX90 S2 View
Base unit front view Base unit front view(3.5" type) (2.5" type)
Drive Enclosure front view Drive Enclosure front view
6
-
7/24/2019 ETERNUS Configuration Guide
8/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
*1: Up to twelve 3.5" disk drives or twenty-four 2.5" disk drives can be installed in each controller enclosure.
(Mixture of 2.5/3.5inch drives in the same enclosure is not supported.)*2: The following table shows the type and number of drive enclosures that can be installed in DX60 S2.
3.5" type
2.5" type
ETERNUS DX60 S2 Product Diagrams
Base unit Drive Enclosure
3.5" type 2.5" type
ETERNUS DX60 S2 Max. 1 Not supported
Not supported Not supported
Server
ETERNUS DX60 S2 base unit
Disk Drive (Option) (Max, 12/24 drives can be installed *1)
......
AC power cable 200V 4m x2
Power distribution unit (AC200V) (Option)
3.5" Drive Enclosure (Option) *2
Disk Drive (Option) (Max, 12 drives can be installed)
......
AC power cable 200V 4m x2
Power distribution unit (AC200V)(Option) (Share with base unit)
SAS cable (0.75m) x2(Attached to Drive Enclosure)
LAN cable (category 5e) 5m x 2(Setup node/Management LAN
Connection)(Option)
Host Interface cable (Option)FC cable (5m) x 2
LAN cable (category 5e)(5m) x2SAS cable (1.5m) x2
Host interface(Standard/Option)
HBA (Host Bus Adaptor):FC / SAS / LAN card
Extension cable (Option)SAS cable (3m or 6m) x2(Order when standard cable is too short)
Controller Enclosure(Standard)
Controller Enclosure(Standard/Option)
Host interface(Standard)
7
-
7/24/2019 ETERNUS Configuration Guide
9/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
Host Interface Option(At least one set of Host interfaces is mandatory forsingle-controller model. And two of the same hostinterface sets are mandatory for dual-controller.)- Fibre Channel- SAS
- iSCSI (1Gbit/s)- iSCSI (10Gbit/s)
- FCoE
*1: Up to twelve 3.5" disk drives or twenty-four 2.5" disk drives can be installed in each controller enclosure.(Mixture of 2.5/3.5inch drives in the same enclosure is not supported.)
*2: Mixture of 3.5" type drive enclosures and 2.5" type drive enclosures enablesmixture of 3.5" drives and 2.5" drives in the same machine.Up to 120 drives can be installed in a single ETERNUS DX80 S2.
Up to 240 drives can be installed in a single ETERNUS DX90 S2.The following table shows the type and number of drive enclosures that can be installed in DX80 S2/DX90 S2.
3.5" type2.5" type3.5" type
2.5" type
ETERNUS DX80 S2, DX90 S2 Product Diagrams
ETERNUS DX90 S2 Max. 9 Max. 9
Max. 9 Max. 9
ETERNUS DX80 S2
Base unit
Drive Enclosure
Server
2.5" type3.5" type
Max. 9Max. 9
Max. 4Max. 4
ETERNUS DX80 S2, DX90 S2 base unit
Disk Drive (Option) (Max, 12/24 drives can be installed *1)
......
Controller Enclosure(One option must be chosen)
AC power cable 200V 4m x2
IEC cable x2 (Option)
Power distribution unit (AC200V)
(Option)
Drive Enclosure (Option)Total four/nine DE (2.5"/3.5") can be installed. *2
Disk Drive (Option) (Max, 12/24 drives can be installed *1)
...... Power distribution unit (AC200V)(Option) (Share with base unit)
SAS cable (0.75m) x2(Attached to Drive Enclosure)
LAN cable (category 5e) 5m x 2(Setup node/Management LAN
Connection)(Option)(Remote monitoring function requires additional LAN
HBA (Host Bus Adaptor):FC / SAS / LAN / FCoE card
Extension cable (Option)SAS cable (3m or 6m) x2(Order when standard cable is too short)
Thin Provisioning Feature (Option)(Max. one license can be installed)
AC power cable 200V 4m x2
IEC cable x2 (Option)
Controller Enclosure(One option must bechosen)
8
-
7/24/2019 ETERNUS Configuration Guide
10/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
i) ETERNUS DX60 S2 base unit (Dual controller type, Fibre Channel connection)
Rackmount type (2U), AC200V model
Enclosure x1- Controller (FC4Gbit/s x 2ports) x2- Cache memory (1G) x2- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.Up to 24 drives can be installed in 2.5" type base unit.Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.One 3.5" Drive Enclosures can be added.
- Contents of Package
Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1User Guide 1 CDRead me first 1
ii) ETERNUS DX60 S2 base unit (Dual controller type, SAS connection)
Rackmount type (2U), AC200V modelEnclosure x1
- Controller (SAS x 2ports) x2- Cache memory (1G) x2- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.2.5" Drive Enclosure cannot be added.One 3.5" Drive Enclosures can be added.
- Contents of Package
Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)Rack mount kit 1 setSafety Precautions 1User Guide 1 CDRead me first 1
(1) ETERNUS DX60 S2 (dual-controller type)
Components
ETERNUS DX60 S2
(2.5inch, 4Gbps, FC, dual-controller)ET062DCFU
ETERNUS DX60 S2
(3.5inch, 4Gbps, FC, dual-controller)ET062DDFU
Product name
Product ID
Configuration
Notes
Components
ETERNUS DX60 S2
(2.5inch, 3Gbps, SAS, dual-controller)
ETERNUS DX60 S2
(3.5inch, 3Gbps, SAS, dual-controller)ET062DCSU ET062DDSU
Product name
Product ID
Configuration
Notes
9
-
7/24/2019 ETERNUS Configuration Guide
11/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(1) ETERNUS DX60 S2 (dual-controller type)
iii) ETERNUS DX60 S2 Base Unit (Dual controller type, iSCSI connection)
Rackmount type (2U), AC200V modelEnclosure x1
- Controller (iSCSI x 2ports) x2- Cache memory (1G) x2- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.2.5" Drive Enclosure cannot be added.One 3.5" Drive Enclosures can be added.
- Contents of Package
Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 setSafety Precautions 1User Guide 1 CDRead me first 1
Components
ETERNUS DX60 S2
(2.5inch, 1Gbps, iSCSI, dual-ET062DCLUProduct ID
Configuration
Notes
ETERNUS DX60 S2
(3.5inch, 1Gbps, iSCSI, dual-ET062DDLU
Product name
10
-
7/24/2019 ETERNUS Configuration Guide
12/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
i) ETERNUS DX60 S2 base unit (Single controller type, Fibre Channel connection)
Rackmount type (2U), AC200V model
Enclosure x1- Controller (FC4Gbit/s x 2ports) x1- Cache memory (1G) x1- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.Up to 24 drives can be installed in 2.5" type base unit.Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.One 3.5" Drive Enclosures can be added.
- Contents of Package
Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1User Guide 1 CDRead me first 1
- Additional Controller module (ETERNUS DX60 S2 Fibre Channel connection)
Additional controller module for DX60 S2 (2.5inch, 4Gbps, FC)[Field] ETEEC6CF-L- Controller x1 (with FC 4Gbps 2port)- Cache memory (1GB x1)
Additional controller module for DX60 S2 (3.5inch, 4Gbps, FC)[Field] ETEEC6DF-L- Controller x1 (with FC 4Gbps 2port)- Cache memory (1GB x1)
(2) ETERNUS DX60 S2 (singl e-cont rol ler type)
Product name ETERNUS DX60 S2
(2.5inch, 4Gbps, FC, Single-controller)
ETERNUS DX60 S2
(3.5inch, 4Gbps, FC, Single-controller)Product ID ET062SCFU ET062SDFU
Configuration
Notes
Components
ETERNUS DX60 S2 (2.5")
ETERNUS DX60 S2 (3.5")
11
-
7/24/2019 ETERNUS Configuration Guide
13/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(2) ETERNUS DX60 S2 (singl e-cont rol ler type)
ii) ETERNUS DX60 S2 base unit (Single controller type, SAS connection)
Rackmount type (2U), AC200V modelEnclosure x1
- Controller (SAS x 2ports) x1- Cache memory (1G) x1- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.Up to 24 drives can be installed in 2.5" type base unit.Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.2.5" Drive Enclosure cannot be added.One 3.5" Drive Enclosures can be added.
- Contents of Package
Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 setSafety Precautions 1User Guide 1 CDRead me first 1
- Additional Controller module (ETERNUS DX60 S2 SAS connection)
Additional controller module for DX60 S2 (2.5inch, 3Gbps, SAS)[Field] ETEEC6CS-L- Controller x1 (with SAS 3Gbps 2port)
- Cache memory (1GB x1)
Additional controller module for DX60 S2 (3.5inch, 3Gbps, SAS)
[Field] ETEEC6DS-L- Controller x1 (with SAS 3Gbps 2port)- Cache memory (1GB x1)
Notes
Product name ETERNUS DX60 S2
(2.5inch, 3Gbps, SAS, Single-
ETERNUS DX60 S2
(3.5inch, 3Gbps, SAS, Single-Product ID ET062SCSU ET062SDSU
Configuration
Components
ETERNUS DX60 S2 (2.5")
ETERNUS DX60 S2 (3.5")
12
-
7/24/2019 ETERNUS Configuration Guide
14/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(2) ETERNUS DX60 S2 (singl e-cont rol ler type)
iii) ETERNUS DX60 S2 Base Unit (Single controller type, iSCSI connection)
Rackmount type (2U), AC200V model
Enclosure x1- Controller (iSCSI x 2ports) x1- Cache memory (1G) x1- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.Up to 24 drives can be installed in 2.5" type base unit.Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.One 3.5" Drive Enclosures can be added.
- Contents of Package
Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1User Guide 1 CDRead me first 1
- Additional Controller module (ETERNUS DX60 S2 iSCSI connection)
Additional controller module for DX60 S2 (2.5inch, 1Gbps, iSCSI)[Field] ETEEC6CL-L- Controller x1 (with iSCSI 1Gbps 2port)- Cache memory (1GB x1)
Additional controller module for DX60 S2 (3.5inch, 1Gbps, iSCSI)[Field] ETEEC6DL-L- Controller x1 (with iSCSI 1Gbps 2port)- Cache memory (1GB x1)
Components
Product name ETERNUS DX60 S2
(2.5inch, 1Gbps, iSCSI, Single-
ETERNUS DX60 S2
(3.5inch, 1Gbps, iSCSI, Single-Product ID ET062SCLU ET062SDLU
Configuration
Notes
ETERNUS DX60 S2 (2.5")
ETERNUS DX60 S2 (3.5")
13
-
7/24/2019 ETERNUS Configuration Guide
15/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
- ETERNUS DX80 S2 base unit (dual-controller type)
Rackmount type (2U), AC200V modelEnclosure x1
- Controller x2- Cache memory (2G) x2- Power Supply Unit x2
- Two sets of Host Interfaces are mandatory.- Up to 24 drives can be installed in 2.5" type.
Up to 12 drives can be installed in 3.5" type.- At least two disk drives are mandatory. Up to 120 drives can be added.- Up to nine 3.5" or four 2.5" Drive Enclosures can be added.
- Contents of Package
Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)Rack mount kit 1 setSafety Precautions 1User Guide 1 CD
Read me first 1
ET082DDUET082DCU
(3) ETERNUS DX80 S2 (dual-controller type)
ETERNUS DX80 S2
(2.5inch, dual-controller type)
ETERNUS DX80 S2
(3.5inch, dual-controller type)
Components
Product ID
Product name
Notes
Configuration
14
-
7/24/2019 ETERNUS Configuration Guide
16/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(3) ETERNUS DX80 S2 (dual-controller type)
- Host interface (ETERNUS DX80 S2)
Two host interface options are mandatory. (Four host ports are mandatory.)Up to four options can be installed. (Up to eight ports can be installed.)Either two or four options should be same type. (Either four or eight ports should be same type.)
Mixing different interfaces is supported.
Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)
[Factory] ETEHH12- Host interface module (FC 16G) x1- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)[Field] ETEHH12-L
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)
[Factory] ETEHF12- Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)
[Field] ETEHF12-L- Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (SAS, 2port)[Factory] ETEHS12- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (SAS, 2port)[Field] ETEHS12-L
- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Factory] ETEHL12
- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Field] ETEHL12-L
- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)[Factory] ETEHY12- Host interface module (iSCSI 10G) x1- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)[Field] ETEHY12-L
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)[Factory] ETEHY1N- Host interface module (iSCSI 10G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)[Field] ETEHY1N-L
- Host interface module (iSCSI 10G) x1
ETERNUS DX80 S2
15
-
7/24/2019 ETERNUS Configuration Guide
17/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(3) ETERNUS DX80 S2 (dual-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12- Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)[Field] ETEHC12-L
- Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)[Factory] ETEHC1N- Host interface module (FCoE) x1
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L- Host interface module (FCoE) x1
[Factory]: Factory mount option
[Field]: Field upgrade option
16
-
7/24/2019 ETERNUS Configuration Guide
18/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
- ETERNUS DX80 S2 base unit (single-controller type)
Rackmount type (2U), AC200V modelEnclosure x1
- Controller x1- Cache memory (2G) x1- Power Supply Unit x2
- One Host Interface set is mandatory.No additional controller can be installed in the base unit of the single controllermodel at the time of shipment.
- Up to 24 drives can be installed in 2.5" type.Up to 12 drives can be installed in 3.5" type.
- At least two disk drives are mandatory. Up to 120 drives can be added.- Up to nine 3.5" or four 2.5" Drive Enclosures can be added.
- Contents of Package Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1User Guide 1 CDRead me first 1
'- Additional Controller module (ETERNUS DX80 S2)
One Controller module can be added on single-controller type.
Additional controller module for DX80 S2[Field] ETEAC8A-L
- Controller x1- Cache memory (2GB x1)
Notes
Components
Configuration
(4) ETERNUS DX80 S2 (Single-controller type)
Product name ETERNUS DX80 S2
(2.5inch, single-controller type)
ETERNUS DX80 S2
(3.5inch, single-controller type)Product ID ET082SCU ET082SDU
ETERNUS DX80 S2
17
-
7/24/2019 ETERNUS Configuration Guide
19/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(4) ETERNUS DX80 S2 (Single-controller type)
- Host interface (ETERNUS DX80 S2)
One host interface option is mandatory. (Two host ports are mandatory.)Up to two options can be installed for single CM model. (Up to four ports can be installed.)Mixing different interfaces is supported for single CM model.
Up to four options can be installed for dual CM model. (Up to eight ports can be installed.)Either two or four options should be same type for dual CM model.(Either four or eight ports should be same type for dual CM model.)
Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)[Factory] ETEHH12- Host interface module (FC 16G) x1- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)
[Field] ETEHH12-L- Host interface module (FC 16G) x1- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)[Factory] ETEHF12- Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)[Field] ETEHF12-L
- Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (SAS, 2port)
[Factory] ETEHS12
- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (SAS, 2port)[Field] ETEHS12-L
- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Factory] ETEHL12- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Field] ETEHL12-L
- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)[Factory] ETEHY12- Host interface module (iSCSI 10G) x1- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Field] ETEHY12-L- Host interface module (iSCSI 10G) x1- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Factory] ETEHY1N- Host interface module (iSCSI 10G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)[Field] ETEHY1N-L
- Host interface module (iSCSI 10G) x1
ETERNUS DX80 S2
18
-
7/24/2019 ETERNUS Configuration Guide
20/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(4) ETERNUS DX80 S2 (Single-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12- Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)[Field] ETEHC12-L
- Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)[Factory] ETEHC1N- Host interface module (FCoE) x1
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L- Host interface module (FCoE) x1
[Factory]: Factory mount option
[Field]: Field upgrade option
19
-
7/24/2019 ETERNUS Configuration Guide
21/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
- ETERNUS DX90 S2 base unit (dual-controller type)
Rackmount type (2U), AC200VEnclosure x1
- Controller x2
- Cache memory (4GB) x2- Power Supply Unit x2
- Two sets of the same Host Interface are mandatory.Up to 24 drives can be installed in 2.5" type.
Up to 12 drives can be installed in 3.5" type.- At least two disk drives are mandatory. Up to 240 2.5" drives can be added.
Up to 120 3.5" drives can be added.- Up to nine Drive Enclosures(2.5"/3.5") can be added.
- Contents of Package
Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)Rack mount kit 1 setSafety Precautions 1User Guide 1 CDRead me first 1
(5) ETERNUS DX90 S2 (dual-controller type)
ETERNUS DX90 S2
(2.5inch, dual-controller type)
ETERNUS DX90 S2
(3.5inch, dual-controller type)ET092DCU ET092DDU
Components
Product name
Product ID
Configuration
Notes
20
-
7/24/2019 ETERNUS Configuration Guide
22/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(5) ETERNUS DX90 S2 (dual-controller type)
- Host interface (ETERNUS DX90 S2)
Two host ports are mandatory. (Four ports host interface are mandatory.)Up to four options can be installed. (Up to eight ports can be installed.)Either two or four options should be same type. (Either four or eight ports should be same type.)
Mixing different interfaces is supported.
Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)
[Factory] ETEHH12- Host interface module (FC 16G) x1- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)[Field] ETEHH12-L
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)
[Factory] ETEHF12- Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)
[Field] ETEHF12-L- Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (SAS, 2port)[Factory] ETEHS12- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (SAS, 2port)[Field] ETEHS12-L
- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Factory] ETEHL12
- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Field] ETEHL12-L
- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)[Factory] ETEHY12- Host interface module (iSCSI 10G) x1- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)[Field] ETEHY12-L
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)[Factory] ETEHY1N- Host interface module (iSCSI 10G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)[Field] ETEHY1N-L
- Host interface module (iSCSI 10G) x1
ETERNUS DX90 S2
21
-
7/24/2019 ETERNUS Configuration Guide
23/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(5) ETERNUS DX90 S2 (dual-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12- Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)[Field] ETEHC12-L
- Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)[Factory] ETEHC1N- Host interface module (FCoE) x1
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L- Host interface module (FCoE) x1
[Factory]: Factory mount option
[Field]: Field upgrade option
22
-
7/24/2019 ETERNUS Configuration Guide
24/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
- ETERNUS DX90 S2 base unit (single-controller type)
Rackmount type (2U), AC200VEnclosure x1
- Controller x1
- Cache memory (4GB) x1- Power Supply Unit x2
- One set of the same Host Interfaces are mandatory.No additional controller can be installed in the base unit of the single controller
model at the time of shipment.- Up to 24 drives can be installed in 2.5" type.
Up to 12 drives can be installed in 3.5" type.- At least two disk drives are mandatory. Up to 240 2.5" drives can be added.
Up to 120 3.5" drives can be added.- Up to nine 3.5" or four 2.5" Drive Enclosures can be added.
- Contents of Package Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 setSafety Precautions 1User Guide 1 CDRead me first 1
- Additional Controller module (ETERNUS DX90 S2)
One Controller module can be added on single-controller type.
Additional controller module for DX90 S2[Field] ETEAC9A-L
- Controller x1
- Cache memory (4GB x1)
(6) ETERNUS DX90 S2 (si ngle-cont rol ler type)
Product name ETERNUS DX90 S2
(2.5inch, single-controller type)
ETERNUS DX90 S2
(3.5inch, single-controller type)Product ID ET092SCU ET092SDU
Configuration
Notes
Components
ETERNUS DX90 S2
23
-
7/24/2019 ETERNUS Configuration Guide
25/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(6) ETERNUS DX90 S2 (si ngle-cont rol ler type)
- Host interface (ETERNUS DX90 S2)
One host interface option is mandatory. (Two host ports are mandatory.)Up to two options can be installed for single CM model. (Up to four ports can be installed.)Mixing different interfaces is supported for single CM model.
Up to four options can be installed for dual CM model. (Up to eight ports can be installed.)Either two or four options should be same type for dual CM model.(Either four or eight ports should be same type for dual CM model.)
Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)[Factory] ETEHH12- Host interface module (FC 16G) x1- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)
[Field] ETEHH12-L- Host interface module (FC 16G) x1- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)[Factory] ETEHF12- Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)[Field] ETEHF12-L
- Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (SAS, 2port)
[Factory] ETEHS12
- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (SAS, 2port)[Field] ETEHS12-L
- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Factory] ETEHL12- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Field] ETEHL12-L
- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)[Factory] ETEHY12- Host interface module (iSCSI 10G) x1- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Field] ETEHY12-L- Host interface module (iSCSI 10G) x1- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Factory] ETEHY1N- Host interface module (iSCSI 10G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)[Field] ETEHY1N-L
- Host interface module (iSCSI 10G) x1
ETERNUS DX90 S2
24
-
7/24/2019 ETERNUS Configuration Guide
26/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(6) ETERNUS DX90 S2 (si ngle-cont rol ler type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12- Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)[Field] ETEHC12-L
- Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)[Factory] ETEHC1N- Host interface module (FCoE) x1
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L- Host interface module (FCoE) x1
[Factory]: Factory mount option
[Field]: Field upgrade option
25
-
7/24/2019 ETERNUS Configuration Guide
27/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
- Disk drive option (2.5inch disk drive)* 2.5inch drives are installed in the 2.5inch type controller enclosure
Disk drive
* Mandatory option
* Up to 24 drives can be installed in a 2.5inch base unit.2.5inch 10krpm SAS disk drive
Factory mount options
Disk Drive(2.5inch) 300GB 10krpm x2 (RAID1) for DX60 S2 ETED3MBDisk Drive(2.5inch) 300GB 10krpm x6 (RAID5) for DX60 S2 ETED3PBDisk Drive(2.5inch) 300GB 10krpm x6 (RAID6) for DX60 S2 ETED3DBDisk Drive(2.5inch) 300GB 10krpm x6 (RAID1+0) for DX60 S2 ETED3SB
Disk Drive(2.5inch) 300GB 10krpm x1 for DX60 S2 ETED3HB
Disk Drive(2.5inch) 450GB 10krpm x2 (RAID1) for DX60 S2 ETED4MBDisk Drive(2.5inch) 450GB 10krpm x6 (RAID5) for DX60 S2 ETED4PBDisk Drive(2.5inch) 450GB 10krpm x6 (RAID6) for DX60 S2 ETED4DBDisk Drive(2.5inch) 450GB 10krpm x6 (RAID1+0) for DX60 S2 ETED4SBDisk Drive(2.5inch) 450GB 10krpm x1 for DX60 S2 ETED4HBDisk Drive(2.5inch) 600GB 10krpm x2 (RAID1) for DX60 S2 ETED6MB
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID5) for DX60 S2 ETED6PBDisk Drive(2.5inch) 600GB 10krpm x6 (RAID6) for DX60 S2 ETED6DBDisk Drive(2.5inch) 600GB 10krpm x6 (RAID1+0) for DX60 S2 ETED6SBDisk Drive(2.5inch) 600GB 10krpm x1 for DX60 S2 ETED6HBDisk Drive(2.5inch) 900GB 10krpm x2 (RAID1) for DX60 S2 ETED9MBDisk Drive(2.5inch) 900GB 10krpm x6 (RAID5) for DX60 S2 ETED9PBDisk Drive(2.5inch) 900GB 10krpm x6 (RAID6) for DX60 S2 ETED9DB
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID1+0) for DX60 S2 ETED9SBDisk Drive(2.5inch) 900GB 10krpm x1 for DX60 S2 ETED9HBField upgrade optionsDisk Drive(2.5inch) 300GB 10krpm x1 for DX60 S2 ETED3HB-LDisk Drive(2.5inch) 450GB 10krpm x1 for DX60 S2 ETED4HB-LDisk Drive(2.5inch) 600GB 10krpm x1 for DX60 S2 ETED6HB-LDisk Drive(2.5inch) 900GB 10krpm x1 for DX60 S2 ETED9HB-L
2.5inch 7.2krpm SAS disk drive
Factory mount options
Disk Drive(2.5inch) 1TB 7.2krpm x2 (RAID1) for DX60 S2 ETEN1MB
Disk Drive(2.5inch) 1TB 7.2krpm x6 (RAID5) for DX60 S2 ETEN1PBDisk Drive(2.5inch) 1TB 7.2krpm x6 (RAID6) for DX60 S2 ETEN1DB
Disk Drive(2.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX60 S2 ETEN1SBDisk Drive(2.5inch) 1TB 7.2krpm x1 for DX60 S2 ETEN1HBField upgrade optionsDisk Drive(2.5inch) 1TB 7.2krpm x1 for DX60 S2 ETEN1HB-L
#1 Two or more disk drives are mandatory for one base unit.#2 Install hot spare disks for stable operation.#3 A mixture of different size disk drives is supported.
The capacity of the hot spare disk should match the capacity of the largest disk drive.Ex.) 450GB/10krpm SAS disk x6 (RAID5) x1,
600GB/10krpm SAS disk x6 (RAID5) x1
=> 600GB disk drive x1 is the hot spare.#4 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives
(same capacity, rotation speed and interface speed) are required.
(7) Options
2.5inch disk drive
Product name
Product name
Product ID
Product ID
ETERNUS DX60 S2
26
-
7/24/2019 ETERNUS Configuration Guide
28/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options
- Disk drive option (3.5inch disk drive)
Disk drive
* Mandatory option* Up to 12 drives can be installed in a 3.5inch base unit or a 3.5inch drive enclosure.
Factory mount options
Disk Drive(3.5inch) 300GB 15krpm x1 for DX60 S2 ETED3HADisk Drive(3.5inch) 300GB 15krpm x6 (RAID5) for DX60 S2 ETED3PADisk Drive(3.5inch) 300GB 15krpm x6 (RAID6) for DX60 S2 ETED3DADisk Drive(3.5inch) 300GB 15krpm x6 (RAID1+0) for DX60 S2 ETED3SA
Disk Drive(3.5inch) 300GB 15krpm x2 (RAID1) for DX60 S2 ETED3MADisk Drive(3.5inch) 450GB 15krpm x2 (RAID1) for DX60 S2 ETED4MADisk Drive(3.5inch) 450GB 15krpm x6 (RAID5)for DX60 S2 ETED4PA
Disk Drive(3.5inch) 450GB 15krpm x6 (RAID6) for DX60 S2 ETED4DADisk Drive(3.5inch) 450GB 15krpm x6 (RAID1+0) for DX60 S2 ETED4SADisk Drive(3.5inch) 450GB 15krpm x1 for DX60 S2 ETED4HADisk Drive(3.5inch) 600GB 15krpm x2 (RAID1) for DX60 S2 ETED6MADisk Drive(3.5inch) 600GB 15krpm x6 (RAID5) for DX60 S2 ETED6PA
Disk Drive(3.5inch) 600GB 15krpm x6 (RAID6) for DX60 S2 ETED6DADisk Drive(3.5inch) 600GB 15krpm x6 (RAID1+0) for DX60 S2 ETED6SADisk Drive(3.5inch) 600GB 15krpm x1 for DX60 S2 ETED6HADisk Drive(3.5inch) 1TB 7.2krpm x2 (RAID1) for DX60 S2 ETEN1MADisk Drive(3.5inch) 1TB 7.2krpm x6 (RAID5) for DX60 S2 ETEN1PADisk Drive(3.5inch) 1TB 7.2krpm x6 (RAID6) for DX60 S2 ETEN1DADisk Drive(3.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX60 S2 ETEN1SA
Disk Drive(3.5inch) 1TB 7.2krpm x1 for DX60 S2 ETEN1HA
Disk Drive(3.5inch) 2TB 7.2krpm x2 (RAID1) for DX60 S2 ETEN2MADisk Drive(3.5inch) 2TB 7.2krpm x6 (RAID5) for DX60 S2 ETEN2PADisk Drive(3.5inch) 2TB 7.2krpm x6 (RAID6) for DX60 S2 ETEN2DADisk Drive(3.5inch) 2TB 7.2krpm x6 (RAID1+0) for DX60 S2 ETEN2SADisk Drive(3.5inch) 2TB 7.2krpm x1 for DX60 S2 ETEN2HADisk Drive(3.5inch) 3TB 7.2krpm x2 (RAID1) for DX60 S2 ETEN3MA
Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID5) for DX60 S2 ETEN3PADisk Drive(3.5inch) 3TB 7.2krpm x6 (RAID6) for DX60 S2 ETEN3DADisk Drive(3.5inch) 3TB 7.2krpm x6 (RAID1+0) for DX60 S2 ETEN3SADisk Drive(3.5inch) 3TB 7.2krpm x1 for DX60 S2 ETEN3HAField upgrade optionsDisk Drive(3.5inch) 300GB 15krpm x1 for DX60 S2 ETED3HA-L
Disk Drive(3.5inch) 450GB 15krpm x1 for DX60 S2 ETED4HA-LDisk Drive(3.5inch) 600GB 15krpm x1 for DX60 S2 ETED6HA-LDisk Drive(3.5inch) 1TB 7.2krpm x1 for DX60 S2 ETEN1HA-LDisk Drive(3.5inch) 2TB 7.2krpm x1 for DX60 S2 ETEN2HA-LDisk Drive(3.5inch) 3TB 7.2krpm x1 for DX60 S2 ETEN3HA-L
#1 Two or more disk drives are mandatory for one base unit.#2 Install hot spare disks for stable operation.
#3 A mixture of different capacity disk drives is supported.When installing different capacity disk drives in one base unit,the capacity of the hot spare disk should match the capacity of the largest disk drive.
Ex.) 450GB/15krpm SAS disk x6 (RAID5) x1, 600GB/15krpm SAS disk x6 (RAID5) x1=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disks (SAS disk drives and Nearline SAS disk drives) is supported.When installing different type disk drives in one base unit,it is recommended that at least one hot spare disk of each type be installed.
#5 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives(same capacity, rotation speed and interface speed) are required.
3.5inch disk drive
Product name Product ID
ETERNUS DX60 S2
27
-
7/24/2019 ETERNUS Configuration Guide
29/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options
- Drive enclosure (3.5inch)
Dual-IOM type supports dual controller model only.
Drive enclosure for DX60 S2 (3.5inch, dual-expander type)[Factory] ETEED2DU
[Field] ETEED2DU-L- Rack mount type (2U)- Enclosure [Expander (SAS 1port) x2, PSU x2] x1- Up to 12 disk drives can be installed in one drive enclosure.- Attachment list
Qty
Rackmount kit 1 set
AC200V power cable 2 4m (NEMA L6-15P)
SAS cable 2 75cm: Bace unit Drive enclosure connection
Disk driveRefer "Disk drive option (3.5inch)"* Up to 12 disk drives can be installed.
Drive enclosure for DX60 S2 (3.5inch, single-expander type)[Factory] ETEED1DU
[Field] ETEED1DU-L- Rack mount type (2U)- Enclosure [Expander (SAS 1port) x1, PSU x2] x1
- Up to 12 disk drives can be installed in one drive enclosure.- Attachment list
Qty
Rackmount kit 1 set
AC200V power cable 2 4m (NEMA L6-15P)SAS cable 1 75cm: Bace unit
Drive enclosure connection
Additional expander for DX60 S2 (3.5inch)[Field] ETEEXD-L
- Attachment list
Qty
IOM 1
SAS cable 1 75cm: Bace unit Drive enclosure connection
Disk driveRefer "Disk drive option (3.5inch)"* Up to 12 disk drives can be installed.
- Extension cable
- The Extension cable (3m) kit option can be ordered if the SAS cables (75cm)supplied with the drive enclosures are too short to connect.
Extension cable between enclosures for DX60 S2 (3m)[Field] ETEC1M3-L
- 1x mini SAS cable 3m
Attachment Notes
Attachment Notes
Attachment Notes
ETERNUS DX60 S2
ETERNUS DX60 S2
28
-
7/24/2019 ETERNUS Configuration Guide
30/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options
- Disk drive option (2.5inch disk drive)* 2.5inch drives are installed in the 2.5inch type controller enclosure and drive enclosures.
Disk drive
* Mandatory option
* Up to 24 drives can be installed in a 2.5inch base unit or a 2.5inch drive enclosure.
2.5inch 10krpm SAS disk drive
Factory mount options
Disk Drive(2.5inch) 300GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED3MCDisk Drive(2.5inch) 300GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED3PCDisk Drive(2.5inch) 300GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED3DC
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED3SC
Disk Drive(2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2 ETED3HCDisk Drive(2.5inch) 450GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED4MCDisk Drive(2.5inch) 450GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED4PCDisk Drive(2.5inch) 450GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED4DCDisk Drive(2.5inch) 450GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED4SCDisk Drive(2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2 ETED4HC
Disk Drive(2.5inch) 600GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED6MCDisk Drive(2.5inch) 600GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED6PCDisk Drive(2.5inch) 600GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED6DCDisk Drive(2.5inch) 600GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED6SCDisk Drive(2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HCDisk Drive(2.5inch) 900GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED9MCDisk Drive(2.5inch) 900GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED9PC
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED9DCDisk Drive(2.5inch) 900GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED9SCDisk Drive(2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2 ETED9HCField upgrade optionsDisk Drive(2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2 ETED3HC-LDisk Drive(2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2 ETED4HC-LDisk Drive(2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HC-L
Disk Drive(2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2 ETED9HC-L
2.5inch 15krpm SAS disk drive
Factory mount options
Disk Drive (2.5inch) 300GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED3MGDisk Drive (2.5inch) 300GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED3PG
Disk Drive (2.5inch) 300GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED3DGDisk Drive (2.5inch) 300GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED3SGDisk Drive (2.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2 ETED3HGField upgrade optionsDisk Drive (2.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2 ETED3HG-L
2.5inch 7.2krpm SAS disk drive
Factory mount options
Disk Drive (2.5inch) 1TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2 ETEN1MCDisk Drive (2.5inch) 1TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2 ETEN1PC
Disk Drive (2.5inch) 1TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2 ETEN1DCDisk Drive (2.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETEN1SCDisk Drive (2.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN1HCField upgrade options
Disk Drive (2.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN1HC-L
2.5inch disk drive
Product name Product ID
Product IDProduct name
Product name Product ID
ETERNUS DX80 S2, DX90
29
-
7/24/2019 ETERNUS Configuration Guide
31/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options
Self Encrypting Disk Drive, 2.5inch 10krpm SAS disk drive
Factory mount options
Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED3MESelf Encrypting Disk Drive (2.5inch) 300GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED3PESelf Encrypting Disk Drive (2.5inch) 300GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED3DESelf Encrypting Disk Drive (2.5inch) 300GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED3SE
Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2 ETED3HESelf Encrypting Disk Drive (2.5inch) 450GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED4MESelf Encrypting Disk Drive (2.5inch) 450GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED4PESelf Encrypting Disk Drive (2.5inch) 450GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED4DESelf Encrypting Disk Drive (2.5inch) 450GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED4SESelf Encrypting Disk Drive (2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2 ETED4HESelf Encrypting Disk Drive (2.5inch) 600GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED6MESelf Encrypting Disk Drive (2.5inch) 600GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED6PE
Self Encrypting Disk Drive (2.5inch) 600GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED6DESelf Encrypting Disk Drive (2.5inch) 600GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED6SESelf Encrypting Disk Drive (2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HESelf Encrypting Disk Drive (2.5inch) 900GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED9ME
Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED9PESelf Encrypting Disk Drive (2.5inch) 900GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED9DESelf Encrypting Disk Drive (2.5inch) 900GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED9SE
Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2 ETED9HEField upgrade optionsSelf Encrypting Disk Drive (2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2 ETED3HE-LSelf Encrypting Disk Drive (2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2 ETED4HE-LSelf Encrypting Disk Drive (2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HE-LSelf Encrypting Disk Drive (2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2 ETED9HE-L
#1 Two or more disk drives are mandatory for one base unit.
#2 Install hot spare disks for stable operation.#3 A mixture of different size disk drives is supported.
The capacity of the hot spare disk should match the capacity of the largest disk drive.Ex.) 450GB/10krpm SAS disk x6 (RAID5) x1,
600GB/10krpm SAS disk x6 (RAID5) x1=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives(same capacity, rotation speed and interface speed) are required.
Product IDProduct name
30
-
7/24/2019 ETERNUS Configuration Guide
32/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options
'- Disk drive option (3.5inch disk drive)
Disk drive
* Mandatory option* Up to 12 drives can be installed in a 3.5inch base unit or a 3.5inch drive enclosure.
Factory mount options
Disk Drive(3.5inch) 300GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED3MDDisk Drive(3.5inch) 300GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED3PDDisk Drive(3.5inch) 300GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED3DDDisk Drive(3.5inch) 300GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED3SD
Disk Drive(3.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2 ETED3HDDisk Drive(3.5inch) 450GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED4MDDisk Drive(3.5inch) 450GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED4PD
Disk Drive(3.5inch) 450GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED4DDDisk Drive(3.5inch) 450GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED4SDDisk Drive(3.5inch) 450GB 15krpm x1 for DX80 S2/DX90 S2 ETED4HDDisk Drive(3.5inch) 600GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED6MDDisk Drive(3.5inch) 600GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED6PD
Disk Drive(3.5inch) 600GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED6DDDisk Drive(3.5inch) 600GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED6SDDisk Drive(3.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HDDisk Drive(3.5inch) 1TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2 ETEN1MDDisk Drive(3.5inch) 1TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2 ETEN1PDDisk Drive(3.5inch) 1TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2 ETEN1DDDisk Drive(3.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETEN1SD
Disk Drive(3.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN1HD
Disk Drive(3.5inch) 2TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2 ETEN2MDDisk Drive(3.5inch) 2TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2 ETEN2PDDisk Drive(3.5inch) 2TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2 ETEN2DDDisk Drive(3.5inch) 2TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETEN2SDDisk Drive(3.5inch) 2TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN2HDDisk Drive(3.5inch) 3TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2 ETEN3MD
Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2 ETEN3PDDisk Drive(3.5inch) 3TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2 ETEN3DDDisk Drive(3.5inch) 3TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETEN3SDDisk Drive(3.5inch) 3TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN3HDField upgrade optionsDisk Drive(3.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2 ETED3HD-L
Disk Drive(3.5inch) 450GB 15krpm x1 for DX80 S2/DX90 S2 ETED4HD-LDisk Drive(3.5inch) 600GB 15krpm x1 for DX80 S2/DX90 S2 ETED6HD-LDisk Drive(3.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN1HD-LDisk Drive(3.5inch) 2TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN2HD-LDisk Drive(3.5inch) 3TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN3HD-L
#1 Two or more disk drives are mandatory for one base unit.#2 Install hot spare disks for stable operation.
#3 A mixture of different capacity disk drives is supported.When installing different capacity disk drives in one base unit,the capacity of the hot spare disk should match the capacity of the largest disk drive.
Ex.) 450GB/15krpm SAS disk x6 (RAID5) x1, 600GB/15krpm SAS disk x6 (RAID5) x1=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disks (SAS disk drives and Nearline SAS disk drives) is supported.When installing different type disk drives in one base unit,it is recommended that at least one hot spare disk of each type be installed.
#5 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives(same capacity, rotation speed and interface speed) are required.
Product name Product ID
3.5inch disk drive
ETERNUS DX80 S2, DX90
31
-
7/24/2019 ETERNUS Configuration Guide
33/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options
- SSD
SSD2.5inch disk drives
Factory mount options
SSD(2.5inch) 100GB x2 (RAID1) for DX80 S2/DX90 S2 ETES1MC
SSD(2.5inch) 100GB x4 (RAID5) for DX80 S2/DX90 S2 ETES1PCSSD(2.5inch) 100GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES1SC
SSD(2.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HC
SSD(2.5inch) 200GB x2 (RAID1) for DX80 S2/DX90 S2 ETES2MCSSD(2.5inch) 200GB x4 (RAID5) for DX80 S2/DX90 S2 ETES2PCSSD(2.5inch) 200GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES2SCSSD(2.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HCSSD(2.5inch) 400GB x2 (RAID1) for DX80 S2/DX90 S2 ETES4MC
SSD(2.5inch) 400GB x4 (RAID5) for DX80 S2/DX90 S2 ETES4PCSSD(2.5inch) 400GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES4SC
SSD(2.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HCSSD(2.5inch) 800GB x2 (RAID1) for DX80 S2/DX90 S2 ETES8MCSSD(2.5inch) 800GB x4 (RAID5) for DX80 S2/DX90 S2 ETES8PCSSD(2.5inch) 800GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES8SCSSD(2.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HC
Field upgrade options
SSD(2.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HC-L
SSD(2.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HC-LSSD(2.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HC-LSSD(2.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HC-L
SSD3.5inch disk drives
Factory mount optionsSSD(3.5inch) 100GB x2 (RAID1) for DX80 S2/DX90 S2 ETES1MDSSD(3.5inch) 100GB x4 (RAID5) for DX80 S2/DX90 S2 ETES1PDSSD(3.5inch) 100GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES1SDSSD(3.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HDSSD(3.5inch) 200GB x2 (RAID1) for DX80 S2/DX90 S2 ETES2MDSSD(3.5inch) 200GB x4 (RAID5) for DX80 S2/DX90 S2 ETES2PD
SSD(3.5inch) 200GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES2SDSSD(3.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HDSSD(3.5inch) 400GB x2 (RAID1) for DX80 S2/DX90 S2 ETES4MDSSD(3.5inch) 400GB x4 (RAID5) for DX80 S2/DX90 S2 ETES4PDSSD(3.5inch) 400GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES4SD
SSD(3.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HDSSD(3.5inch) 800GB x2 (RAID1) for DX80 S2/DX90 S2 ETES8MD
SSD(3.5inch) 800GB x4 (RAID5) for DX80 S2/DX90 S2 ETES8PDSSD(3.5inch) 800GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES8SDSSD(3.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HDField upgrade optionsSSD(3.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HD-LSSD(3.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HD-LSSD(3.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HD-LSSD(3.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HD-L
* SSD supports RAID1, RAID1+0 and RAID5 only.
Product IDProduct name
ETERNUS DX80 S2, DX90
32
-
7/24/2019 ETERNUS Configuration Guide
34/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options
- Drive enclosure (2.5inch)
Dual-IOM type supports dual controller model only.
Drive enclosure for DX80 S2/DX90 S2 (2.5inch, dual-IOM type)
[Factory] ETEAD2CU[Field] ETEAD2CU-L
- Rack mount type (2U)- Enclosure [IOM (SAS 1port) x2, PSU x2] x1- Up to 24 disk drives can be installed in one drive enclosure.- Attachment list
Qty
Rackmount kit 1 set
AC200V power cable 2 4m (NEMA L6-15P)SAS cable 2 75cm: Bace unit
Drive enclosure connectionDisk driveRefer "Disk drive option (2.5inch)"* Up to 24 disk drives can be installed.
Drive enclosure for DX80 S2/DX90 S2 (2.5inch, single-IOM type)
[Factory] ETEAD1CU[Field] ETEAD1CU-L
- Rack mount type (2U)- Enclosure [IOM (SAS 1port) x1, PSU x2] x1- Up to 24 disk drives can be installed in one drive enclosure.- Attachment list
Qty
Rackmount kit 1 set
AC200V power cable 2 4m (NEMA L6-15P)SAS cable 1 75cm: Bace unit
Drive enclosure connection
Additional IOM for DX80 S2/DX90 S2
[Field] ETEAMA-L- Attachment list
Qty
IOM 1
SAS cable 1 75cm: Bace unit Drive enclosure connection
Disk drive
Refer "Disk drive option (2.5inch)"* Up to 24 disk drives can be installed.
NotesAttachment
Attachment Notes
Attachment Notes
ETERNUS DX80 S2, DX90 S2
33
-
7/24/2019 ETERNUS Configuration Guide
35/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options
- Drive enclosure (3.5inch)
Dual-IOM type supports dual controller model only.
Drive enclosure for DX80 S2/DX90 S2 (3.5inch, dual-IOM type)[Factory] ETEAD2DU
[Field] ETEAD2DU-L- Rack mount type (2U)- Enclosure [IOM (SAS 1port) x2, PSU x2] x1- Up to 12 disk drives can be installed in one drive enclosure.- Attachment list
Qty
Rackmount kit 1 set
AC200V power cable 2 4m (NEMA L6-15P)
SAS cable 2 75cm: Bace unit Drive enclosure connectionDisk drive
Refer "Disk drive option (3.5inch)"* Up to 12 disk drives can be installed.
Drive enclosure for DX80 S2/DX90 S2 (3.5inch, single-IOM type)[Factory] ETEAD1DU
[Field] ETEAD1DU-L- Rack mount type (2U)- Enclosure [IOM (SAS 1port) x1, PSU x2] x1- Up to 12 disk drives can be installed in one drive enclosure.
- Attachment list
Qty
Rackmount kit 1 set
AC200V power cable 2 4m (NEMA L6-15P)SAS cable 2 75cm: Bace unit Drive enclosure connection
Additional IOM for DX80 S2/DX90 S2[Field] ETEAMA-L
- Attachment list
Qty
Rackmount kit 1 set
SAS cable 2 75cm: Bace unit Drive enclosure connection
Disk driveRefer "Disk drive option (3.5inch)"* Up to 12 disk drives can be installed.
- Extension cable
- The Extension cable (3m) kit option can be ordered if the SAS cables (75cm)supplied with the drive enclosures are too short to connect.
Extension cable between enclosures for DX80 S2/DX90 S2 (3m)[Field] ETEC1Q3-L- QSFP cable (3m) x1
Extension cable between enclosures for DX80 S2/DX90 S2 (6m)[Field] ETEC1Q6-L
- QSFP cable (6m) x1
Notes
Attachment
Attachment
Notes
Attachment Notes
ETERNUS DX80 S2, DX90 S2
ETERNUS DX80 S2, DX90 S2
34
-
7/24/2019 ETERNUS Configuration Guide
36/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
- Thin Provisioni ng Feature
Single controller model does not support Thin Provisioning Feature.
Thin Provisioning Feature License for DX80 S2[Factory] ETEL8T[Field] ETEL8T-L
- License label x1- To use Thin provisioning Feature, one license is required per one unit.
Thin Provisioning Feature License for DX90 S2[Factory] ETEL9T
[Field] ETEL9T-L- License label x1- To use Thin provisioning Feature, one license is required per one unit.
[Factory]: Factory mount option[Field]: Field upgrade option
(7) Options
ETERNUS DX80 S2
ETERNUS DX90 S2
35
-
7/24/2019 ETERNUS Configuration Guide
37/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
- Outlet box
- Power distribution unit
Power distribution unit for DX60 S2/DX80 S2/DX90 S2(AC200-240V, 1U Max 2 enclosures connection)ETEP4BU-LRack mount type (1U), AC200VThere are up to two options for connecting a base unit anddrive enclosure.
(PDU for Base unit x2 or PDU for Drive enclosure x2 orPDU for Base unit x1 + PDU for Drive enclosure x1)
- Power distribution unit (AC200V)1- Input AC cable (NEMA L6-15P, 3m) x2
- Output AC cable (3m) x4, Rack mount kit x1
NEMA L6-15 outlet
Power distribution unit for DX60 S2/DX80 S2/DX90 S2(AC200-240V, 2U, Max 6 enclosures connection)
ETEP12U-LRack mount type (1U), AC200VUp to six base units or drive enclosures can be connected.
(Base unit x6,Base unit x2 + Drive enclosure x4Base unit x1 + Drive enclosure x5, etc.)
- Power distribution unit (AC200V)1
- Input AC cable (NEMA L6-20P, 4m) x2
- Output AC cable (3m) x12, Rackmount kit x1
NEMA L6-20 outlet
Power distribution unit for DX60 S2/DX80 S2/DX90 S2(AC200-240V, 2U, Max 8 enclosures connection)
ETEP16U-LRack mount type (1U), AC200VUp to eight base units or drive enclosures can be connected.
(Base unit x8,
Base unit x2 + Drive enclosure x6Base unit x1 + Drive enclosure x7, etc.)- Power distribution unit (AC200V)1- Input AC cable (NEMA L6-30P, 4m) x2- Output AC cable (3m) x16, Rackmount kit x1
NEMA L6-30 outlet
(7) Options
ETERNUS DX60 S2, DX80 S2, DX90
36
-
7/24/2019 ETERNUS Configuration Guide
38/42
ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options
- IEC Power cableAC cable (IEC60320 C13 - IEC60320 C14)
ST-PWG13- To connect IEC 320-C14 components,
one option is required per one base unit or drive enclosure.- AC200V cable (IEC320 C14, 3m) x2
200V (Standard) IEC320
NEMA L6-15 outlet IEC320 outlet
ETERNUS DX60 S2, DX80 S2, DX90
37
-
7/24/2019 ETERNUS Configuration Guide
39/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
Power Synchronized UnitST-PSM20U
- Power Synchronized Unit x1- RS232C cable x2- Parts kit for 19-inch rack
AC Sensor Unit (AC200V)ST-PSL20SU- AC Sensor Unit x1- RCI cable (4m) x1
- RCI brunch connector x1- Parts kit for 19-inch rack
Note that power cords (for AC power input) for power synchronized units and power cords (for AC sensor) to connect
server UPS units to power synchronized units or AC sensor units are not supplied with power synchronized units.
The IEC 60320-C14 port type is used for the AC IN ports and the SENSOR ports of the power synchronized units.
This port type is also used for the AC IN ports of the AC sensor units.Check the specifications of the power sockets and server UPS unit outlets that are to be used for the powersynchronized units and AC sensor units. Prepare the required number of appropriate power cords.
Power cord (for AC power input)- Each Power Synchronized Unit requires one Power cord.- The voltage for the AC IN port is 10A 250V or less.
Power cord (for AC sensor)
- Each server UPS Unit that is to be connected to The Power Synchronized Unit requires one Power cord.- Each AC sensor Unit requires one Power cord.
Be sure that the power cords have the approval of the appropriate safety agencies of the country where the equipmentwill be used.
(7) Options
ETERNUS DX60 S2, DX80 S2, DX90
38
-
7/24/2019 ETERNUS Configuration Guide
40/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
- Fibre channel cable (Fibre channel, 10Gbits/s iSCSI, FCoE connection)
Fibre channel cableLength
CBL-MLLC05 5m LC-LC
CBL-MLLC10 10mCBL-MLLC20 20mCBL-MLLC30 30mCBL-MLLC40 40mCBL-MLLC50 50mCBL-MLLD1A 100mCBL-MLLB02 * 2mCBL-MLLB05 * 5m
- m
* For connection between same rack.Fibre channel card, Fibre channel switch
- SAS cable (SAS connection)
SAS cable
LengthCBL-SASB1U 1.5m - SAS connectionCBL-SASB3U 3m
CBL-SASB6U 6m
SAS card
- Twinax Cable (10 Gbit/s iSCSI withtout SFP+, FCoE without SFP+ connection)
Twinax cable
TypeEBRTWX11 1m Brocade/10G-SFPP-TWX-0101EBRTWX31 3m Brocade/10G-SFPP-TWX-0301EBRTWX51 5m Brocade/10G-SFPP-TWX-0501S26361-F4571-L10 7m Cisco/SFP-H10GB-ACU7M
S26361-F4571-L11 10m Cisco/SFP-H10GB-ACU10M
S26361-F3989-L10 5m Fujitsu/T26139-Y4006-M5
FCoE, iSCSI card
Product ID Notes
Notes
(8) Cables
Product ID
Product ID Notes
With cover
Without cover
ETERNUS DX60 S2ETERNUS DX80 S2ETERNUS DX90 S2
ETERNUS DX60 S2ETERNUS DX80 S2ETERNUS DX90 S2
ETERNUS DX80 S2
ETERNUS DX90 S2
39
-
7/24/2019 ETERNUS Configuration Guide
41/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
- Rack for ETERNUS DX60 S2, DX80 S2, DX90 S2
ETERNUS DX80 S2, DX90 S2 can be installed in the following racks.
Base Rack Expansion Rack19-inch Rack Model 2742 Standard 42U 19R-274A2 19R-274B219-inch Rack Model 2737 Standard 37U 19R-273A2 19R-273B2
19-inch Rack Model 2724 Standard 24U 19R-272A2 -19-inch Rack Model 2642 Slim 42U 19R-264A2 19R-264B219-inch Rack Model 2624 Slim 24U 19R-262A2 -19-inch Rack Model 2616 Slim 16U 19R-261A2 -19-inch rack without stabilizers 40U ETNRKC2U ETNRKD2U19-inch rack with stabilizers 40U ETNRKC1U ETNRKD1U
- Notes
- Height and rack installation order are as follows.
ETEAD2CU, ETEAD2CU-LETEAD2DU, ETEAD2DU-L
ETERNUS DX80 S2 base unit ET082DCU, ET082DDUETERNUS DX90 S2 base unit ET092DCU, ET092DDU
ETEP4BU-L 1UETEP12U-L
ETEP16U-L
2
HeightProduct name Install order for the
rack
1
Drive enclosure 3
Power distribution unit (AC200V)2U
2U
(9) Rack
Product ID
Product name Height Product ID
40
-
7/24/2019 ETERNUS Configuration Guide
42/42
ETERNUS DX60 S2, DX80 S2, DX90 S2
B025C1020H
B025C1120H
B025C1220H
B011103H0H
B0214G2H0HB013162H0HAIX
ETERNUS Multipath Driver V2 (Linux 32bit/64bit)
AIX ETERNUS Multipath Driver 2
Product ID Product name
Windows ETERNUS Multipath Driver for Entry Model V2.x
Windows ETERNUS Multipath Driver for Standard Model V2.x
Windows ETERNUS Multipath Driver for Enterprise Model V2.x
Solaris ETERNUS Multipath Driver 3.x
(10) ETERNUS Multipath Driver
OS
Windows
Solaris
Linux