Essencia - Installation manual

36
ESSENCIA ® INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER TO BE KEPT BY THE OWNER

Transcript of Essencia - Installation manual

Page 1: Essencia - Installation manual

ESSENCIA®

INSTALLATION INSTRUCTIONS

IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER

TO B

E K

EP

T B

Y T

HE

OW

NE

R

Page 2: Essencia - Installation manual

2

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

TABLE OF CONTENT

IMPORTANT SAFETY INSTRUCTIONS .....................................................................................................................1

PARTS & TOOLS ...................................................................................................................................................3

SITE PREPARATION .............................................................................................................................................6

INSTALLATION

• REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH ..............................................................7

• REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH .....................................................22

CUTTING TEMPLATES: ELECTRONIC CONTROLS ..................................................................................................34

Page 3: Essencia - Installation manual

1 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSE

NC

IA® -

in

sta

lla

tio

nIMPORTANT SAFETY INSTRUCTIONS PERTAINING TO RISKS OF FIRE, ELECTROCUTION OR PERSONAL INJURY

ESSENCIA® COLLECTION

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS • SAVE THESE INSTRUCTIONS

THIS DOCUMENT SUPERCEDES THE INSTALLATION INSTRUCTION IN THE OWNER’S MANUAL.

WARNING

• Risk of hyperthermia; people using medication and/or having an adverse medical history should consult a physician before using a Hydro-thermo massage® bathtub equipped with a heater.

• Risk of hyperthermia and possible drowning: do not use a Hydro-thermo massage® bathtub equipped with heater immediately following strenuous exercise.

• Risk of fetal injury; pregnant or possibly pregnant women should consult a physician before using a Hydro-thermo massage® bathtub equipped with a heater.

• Risk of accidental injury or drowning; do not use drugs or alcohol before or during the use of a Hydro-thermo massage® bathtub equipped with a heater.

• Use this unit only for its intended purposes or as described in this manual. Use only accessories or devices recommended by the manufacturer.

• Risk of hyperthermia and possible drowning. Check and adjust water temperature before use. Water temperature exceeding 100ºF (38ºC) may be injurious to your health.

• To reduce the risk of injury, as with any other conventional bath, do not allow children or physically impaired people to use this unit unless they are closely supervised at all times.

• To avoid injury, exercise care when entering or exiting the Thermomasseur®.

• The Geysair (option) should always be connected to the hot water intake. If it is not the case, then, the Geysair option should be deactivated via the bath control.

RISK OF ELECTRICAL SHOCK

• Disconnect electric power before servicing.

• Do not permit electrical appliances (hair dryer, lamp, telephone, radio, television, etc.) within 5’ (1,5 m) of the Thermomasseur®.

• Before using the Thermomasseur®, its exterior construction (podium or skirting) should be finished so that a bather cannot accidentally come in contact with electrical components (turbine and power module).

• For indoor use only.

Page 4: Essencia - Installation manual

2

ESSE

NC

IA® -

in

sta

lla

tio

n

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

ESSENCIA® COLLECTION

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS • SAVE THESE INSTRUCTIONS

THIS DOCUMENT SUPERCEDES THE INSTALLATION INSTRUCTION IN THE OWNER’S MANUAL.

ELECTRICAL CONNECTIONS:

• Never drop or insert objects into any openings.

• The Thermomasseur® must be connected only to a supply circuit that is protected by a 15 amp class A ground fault circuit interrupter (GFCI) for baths with 1 heated backrest and a 20 amp (GFCI) for baths with Geysair or for baths with 2 heated backrests. This interrupter is supplied by a certified electrician and must be tested on a regular basis in accordance with manufacturer’s instructions. The GFCI ground must be connected. If defective, do not use the Thermomasseur®. Disconnect immediately and call a certified electrician.

• Use 12 AWG (or greater) copper conductors that resist temperatures of at least 194ºF (90ºC).

• Canada only: for permanently connected units. A green-colored terminal (or a wire connector marked g., gr., ground or grounding) is provided within the terminal compartment (not applicable if unit supplied with an electric plug). To reduce the risk of electrocution, connect this terminal or connector to the grounding terminal of your electric service or supply panel with conductor equivalent in size to the circuit conductors supplying the equipment and be 12 AWG or more.

• All electrical connections must be carried out by a certified electrician and must respect federal, provincial/state, and local building codes and regulations.

• Install in accordance with manufacturer’s installation instructions.

• For Geysair-equipped baths using remote turbine installation (not mounted on the bath), grounding continuity must be tested between the bath grounding terminal and the bath power supply. Failure to perform the grounding continuity test could result in serious personal injury.

WATER LEAK TEST

• Once plumbing is fully installed and before beginning any other work, fill the ThermoMasseur® with water to overflow level and wait 30 minutes. Check all plumbing hook-ups and bath for leaks. BainUltra® is not responsible for any water damage caused by improper installation (see Warranty section).

IMPORTANT SAFETY INSTRUCTIONS (cont’d) PERTAINING TO RISKS OF FIRE, ELECTROCUTION OR PERSONAL INJURY

Page 5: Essencia - Installation manual

3 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

nPARTS & TOOLS REQUIRED

STANDARD PARTS - PLUMBING ESSENCIA 6838 & OVAL 7236

PLUMBINGSTANDARD PARTS - ESSENCIA DESIGNOPTIONAL PARTS - ESSENCIA 6838(1)

DESCRIPTION QTY

A Plated drain clicker 1

B Locking nut 1

C Strainer 1

D Rubber seal 1

E PVC Wired drain shoe 1

F PVC Piping 1-1/2’’ X 2’’ 1

G PVC Tee Connector 1-1/2’’ F-F 1

DESCRIPTION QTY

H Plated drain clicker 1

I Strainer 1

J Rubber seal 1

K Brass drain shoe 1

L 4 in. brass tailpiece 1

M Nylon conic shaped seal for drain 1

N Brass nut 2

O Brass pipe 1-1/2” x 3” with flange 1

P Nylon flat seal with flange 1

Q 1-1/2” male threaded adaptor 1

J

I

L

H

EF

G

A

B

C

D

MNO

PQ

K

(1) : INTEGRATED WASTE & OVERFLOW OPTION

Page 6: Essencia - Installation manual

4

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

PARTS & TOOLS REQUIRED

STANDARDS PARTS – FLOOR ANCHOR

DESCRIPTION QTY

R Floor anchor 2

S Threaded anchor (Oval 7236 & Design) 2

T 1/2” Nut – 13 zinc (Oval 7236 & Design) 2

U 1/2” Flat washer 2 (Oval 7236 & Design)

V #10 X 1-1/2” Countersunk head screw 12 (Oval 7236 & Design)

W Seals (Oval 7236 & Design) 2

T

U

V

S

W

R

OPTIONAL PARTS – PLUMBING (2)

ISLAND TUB DRAIN® (ITD) KIT

• Makes installation and servicing easier for removal of bath.

• Allows you to connect the bath drain tailpiece to the plumbing pipe without need for tightening to seal once the bath is lowered to the floor.

(2): REQUIRED WHEN NO ACCESS IS POSSIBLE UNDER the BATH. Available only with ESSENCIA DESIGN & 6838 with integrated waste & Overflow.

Page 7: Essencia - Installation manual

5 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

nPARTS & TOOLS REQUIRED PARTS & TOOLS REQUIRED

STANDARDS PARTS – THERMOMASSEUR®

DESCRIPTION QTY

A Turbine 1

B MiaPlus® Control(Essencia Design) 1

C Contrôle MiaMulti® 1 (Essencia 6838 & Oval 7236)

D 15’ extension cord 1

B

C

Installation template

48-inch level

Measuring tape

Teflon tape

Caulking gun

Silicone

ABS & PVC Glue

Square/Phillips #2 Screwdriver

3/4” Ratchet

Adjustable clamps

PARTS & TOOLS REQUIRED

D

A

Page 8: Essencia - Installation manual

6

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

SITE PREPARATION

PLUMBING

• See faucet manufacturer’s specifications for zoning and plan water supply location accordingly.

• Position drain according to bath’s technical specifications.

WARNING

• Baths from Essencia® collection cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models.

BEDDING

• Before installing, ensure that the floor underneath the bath can support 1500 lb (680 kg). The bath may sit directly on the floor. The bathtub can also sit on a concrete bed. In that case, it is recommended to isolate the concrete between two plastic sheets: one installed on the floor and the other under the bath.

SERVICE ACCESS AND VENTILATION

• A service access is necessary. Minimum dimensions are 22 in. x 18 in. (55 cm x 46 cm) to properly reach all electrical components of the system.

• An air vent is necessary. Minimum dimensions are: 2 in. x 4 in. (5 cm x 10 cm) to ensure proper functioning of the turbine.

There is a technical specification sheet for each BainUltra® ThermoMasseur® which includes information such as necessary dimensions of site before installation.

If you do not already have the technical specifications, download from the BainUltra® Web site at: bainultra.com or call us at: 1 800 463-2187.

FLOOR

1500 LB (680 KG)

Page 9: Essencia - Installation manual

7 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

nREMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

6"

10"

25,125"

68"

38"

25,125"

12"

14,5"

INTEGRATED waste & overflow

Standard waste & overflow

Wiring

Air pipe

Floor anchor

Floor anchor

Access trap

4,5"

19,5"

72"

36"

9,375"

10,5"

12"

WasteOverflowWiring

Air pipe Accesstrap

Floor anchor Floor anchor

PLUMBING – FLOOR LAYOUT FOR PIPES AND ACCESS

ESSENCIA 6838

ESSENCIA OVAL 7236

NOTE : Please refer to the Installation Template provided with your ESSENCIA bath. However, if it is missing, please contact us at 1-800-463-2187 to order it.

Page 10: Essencia - Installation manual

8

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

1 PLUMBING - ESSENCIA 6838

HELPFUL TIP:

• Carefully place the tub on its side, on a blanket or a corrugated cardboard.

Measure & Align (2x)

Floor anchor

2"

19,5"

72"

36"

9,375"

11"

9,5"

Waste & OverflowWiring

Air pipe Access trap

Floor anchor Floor anchor

ESSENCIA DESIGN

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

PLUMBING – FLOOR LAYOUT FOR PIPES AND ACCESS (cont’d)

R

NOTE : Please refer to the Installation Template provided with your ESSENCIA bath. However, if it is missing, please contact us at 1-800-463-2187 to order it.

Page 11: Essencia - Installation manual

9 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

n

E

O N M

F

P

G

Q

D

J

L

K

WARNING

• If necessary adjust length of the flexible overflow piping connected to the overflow.

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

STANDARD PARTS - PLUMBING ESSENCIA 6838

OPTIONNAL PARTS - PLUMBING(1) ESSENCIA 6838

Flexible Overflow Piping (Factory installed)

Flexible Overflow Piping (Factory installed)

(1) : INTEGRATED WASTE & OVERFLOW OPTION

DESCRIPTION QTY

A Plated drain clicker 1

B Locking nut 1

C Strainer 1

D Rubber seal 1

E PVC Wired drain shoe 1

F PVC Piping 1-1/2’’ X 2’’ 1

G PVC Tee Connector 1-1/2’’ F-F 1

DESCRIPTION QTY

H Plated drain clicker 1

I Strainer 1

J Rubber seal 1

K Brass drain shoe 1

L 4 in. brass tailpiece 1

M Nylon conic shaped seal for drain 1

N Brass nut 2

O Brass pipe 1-1/2” x 3” with flange 1

P Nylon flat seal with flange 1

Q 1-1/2” male threaded adaptor 1

Page 12: Essencia - Installation manual

10

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

1 PLUMBING - ESSENCIA OVAL 7236

HELPFUL TIP:

• Carefully place the tub on its side, on a blanket or a corrugated cardboard.

Measure & Align (2x)

S

STANDARD PARTS - PLUMBING ESSENCIA OVAL 7236

EFG

D

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

Threaded anchor

DESCRIPTION QTY

A Plated drain clicker (p. 3) 1

B Locking nut (p. 3) 1

C Strainer (p. 3) 1

D Rubber seal 1

E PVC Wired drain shoe 1

F PVC Piping 1-1/2’’ X 2’’ 1

G PVC Tee Connector 1-1/2’’ F-F 1

WARNING

• If necessary adjust length of the flexible overflow piping connected to the overflow.

• Adjust length on the straight part of the brass overflow pipe « F » to fit with the drain position that varies with different bath models.

• Fix anchors « S » to floor with the provided screws « V » (p. 4).

Flexible Overflow Piping (Factory installed)

Page 13: Essencia - Installation manual

11 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

n

1 PLUMBING - ESSENCIA DESIGN

HELPFUL TIP:

• Carefully place the tub on its side, on a blanket or a corrugated cardboard.

S

STANDARD PARTS - PLUMBING ESSENCIA DESIGN

WARNING

• Fix anchors « S » to floor with the provided screws « V » (p. 4).

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

Threaded anchor

Measure & Align (2x)

Flexible Overflow Piping (Factory installed)

DESCRIPTION QTY

H Plated drain clicker (p. 3) 1

I Strainer (p. 3) 1

J Rubber seal 1

K Brass drain shoe 1

L 4 in. brass tailpiece 1

M Nylon conic shaped seal for drain 1

N Brass nut 2

O Brass pipe 1-1/2” x 3” with flange 1

P Nylon flat seal with flange 1

Q 1-1/2” male threaded adaptor 1

O N MPQ

J

L

K

Page 14: Essencia - Installation manual

12

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

2 TURBINE & GEYSAIR INSTALLATION (FOR THERMOMASSEUR®)

WARNING

• Access to GeysairTM backflow preventer is necessary for cleaning of the filter.

• Baths from Essencia™ collection cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models.

• Geysair component cannot be remote mounted. It must stay at original position, attached to bath. Must never be unplugged.

TURBINE REMOTE MOUNTING

SEE STEP 7 page 17

Geysair Hose and Back Flow Preventer

Hot Water Supply

1-1/2 I.D. PVC AIR INTAKE PIPE («TIGERFLEX®» FLEXIBLE PVC)

1-1/2 I.D. ABS, PVC PIPE (RIGID or «TIGERFLEX») & Fittings (not included)

3 ELECTRICAL WIRING OF OPTIONAL COMPONENTS

REMOTE MOUNTING of CONTROL MODULES

SEE STEP 8 page 18

Page 15: Essencia - Installation manual

13 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

nPARTS & TOOLS REQUIRED

4 BATH INSTALLATION - ESSENCIA 6838

HELPFUL TIPS:

• Carefully place the tub on its side, on a blanket or a corrugated cardboard.

• To easily manipulate the bathtub in a safe way during installation, we recommend using moving straps.

4“ Minimum

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

Floor surface

Floor anchor R

Anchor

R

WARNING

• Be sure the floor is leveled. Use shims as needed.

• Do not remove the protective plastic film on the tub and place a drop-cloth in the tub during installation to protect the acrylic.

• Apply a bead of silicone around the perimeter of the bath.

• The tub must be securely anchored to floor.

• Install the bath on anchors « R » previously screwed to floor. Remove exceeding silicone.

Measure & Align (2x)

Page 16: Essencia - Installation manual

14

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

4 BATH INSTALLATION -

ESSENCIA OVAL 7236 & DESIGN

HELPFUL TIPS:

• Carefully place the tub on its side, on a blanket or a corrugated cardboard.

• To easily manipulate the bathtub in a safe way during installation, we recommend using moving straps.

1“ Maximum

Measure & Align (2x)

Threaded Anchor

T

U

W

S

WARNING

• Be sure the floor is leveled. Use shims as needed.

• Do not remove the protective plastic film on the tub and place a drop-cloth in the tub during installation to protect the acrylic.

• Apply a bead of silicone around the perimeter of the bath once on the floor.

• The tub must be securely anchored to floor.

• Install the bath on anchors « S » previously screwed to floor. Remove exceeding silicone.

• Connect the drain.

• Attach bath to floor by screwing washers « U » and nuts « T » to anchors « S ».

• Close with the seals « W ».

Floor surface

S

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

Page 17: Essencia - Installation manual

15 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

nREMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

5 ELECTRONIC CONTROL INSTALLATION – MIAPLUS® & MIAMULTI® (OPTIONAL) LOCATION

5 ELECTRONIC CONTROL INSTALLATION – DOT

Jig saw with fine cut blade

Drill

1/4 in. drill bit

Push wiring through drilled holes.

Remove protective film from watertight seal.

Secure to the wall with permanent waterproof sealant (mold-free clear silicone for bathrooms).

Secure temporarily with a tape for about 24 h.

Push wiring through drilled holes.

Remove protective film from watertight seal.

Secure to the wall with permanent waterproof sealant (mold-free clear silicone for bathrooms).

Secure temporarily with a tape for about 24 h.

TOOLS REQUIRED

TOUCH PAD INSTALLATION

TOUCH PAD INSTALLATION

LOCATION: Determine the most convenient location, on the wall close to tub. Peel off the protective film of sticker behind the control. You can add a silicone bead to secure to the wall.

WARNING

• Baths from Essencia® collection cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models.

• DRILLING OF WALL: Refer to the Cutting Template on page 34 for the location and diameter of the holes.

WARNING

• If the control is not factory installed, you will find it attached to the turbine, or to the electronic control modules.

7/8 in. Hole saw

Drill

TOOLS REQUIRED

DOT WarmTouchShell® (WTS)

DOT Chromatherapy (LED)

Page 18: Essencia - Installation manual

16

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

1”

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

WARNING

• Choose a location for the turbine with the shortest possible distance from the Thermomasseur® bath, no more than 15 ft. (4,6m), and a maximum of six elbow directional changes to ensure system performance. It can be under the floor, in a closet or any other place that can hide the turbine and if needed optional modules. Easy access must remain possible at all time and sufficient air ventilation is necessary for turbine.

• A service access is necessary. Minimum dimensions are 22 in. x 18 in. (55 cm x 46 cm) to properly reach all electrical components of the system.

• An air vent is necessary. Minimum dimensions are: 2 in. x 4 in. (5 cm x 10 cm) to ensure proper functioning of the turbine.

• GeysairTM cannot be remotely installed.

6 REMOTE MOUNTING OF TURBINE

Bottom of door When located in an enclosed location.

Floor

Page 19: Essencia - Installation manual

17 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

nREMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

WARNING

• For GeysairTM equipped baths using remote turbine installation (not mounted on the bath), grounding continuity must be tested between the bath grounding terminal and the bath power supply. Failure to perform the grounding continuity test could result in serious personal injury.

7 REMOTE MOUNTING OF TURBINE - AIR PIPE (THERMOMASSEUR®)

7 REMOTE MOUNTING OF TURBINE - ELECTRICAL CONNECTIONS (THERMOMASSEUR®)

• See page 20 for electrical diagram

Junction box Canada

GEYSAIR (option)

TO GFCI Outlet United States

EXTENSION CORD

(If required for longer distance, contact BainUltra for ordering)

GEYSAIR CONNECTION

1-1/2 I.D. ABS, PVC PIPE (RIGID or «TIGERFLEX») & Fittings (not included)

Page 20: Essencia - Installation manual

18

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

C

A

D

E

B

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

8 REMOTE MOUNTING OF TURBINE – ELECTRICAL CONNECTIONS OF OPTIONAL THERAPIES

• See page 20 for electrical diagram.

WARNING

• Electrical outlet must be installed by a certified electrician. Installation must be conducted in accordance with all local, provincial/state, and federal building/electrical codes and regulation.

• Connect electrical supply only after all low voltage wiring is properly installed on turbine.

• If you did not follow this last step, shut off and then restart your home’s circuit breaker.

• Turbine and air pipe should be clear of building materials and wiring.

A: 2nd Heated Backrest

B: Chromatherapy (LED)

C: MiaPlus®

D: MiaMulti® (Option)

E : AromaCloud®

Junction box Canada

Junction box Canada

TO GFCI Outlet United States

TO GFCI Outlet United States

Match the colors of the plug-in cables with those

of the turbine terminals

Page 21: Essencia - Installation manual

19 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

n

A : WarmTouchShell®

B: Chromatherapy (LED)

C : DOT WarmTouchShell®

D : DOT Chromathérapie

E : AromaCloud®

C

C

A

D

D

B

DOT WarmTouchShell® (WTS)

DOT Chromothérapie (DEL)

8 REMOTE MOUNTING OF OPTIONAL THERAPIES (TUB ONLY) – ELECTRICAL CONNECTIONS

• See page 21 for electrical diagram.

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

E

TO GFCI Outlet United States

TO GFCI Outlet United StatesJunction box

Canada

Junction box Canada

Page 22: Essencia - Installation manual

20

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

15A CIRCUIT20A CIRCUIT

NEUTRAL N L LOAD NEUTRAL N L LOAD

GROUND FAULT CIRCUIT INTERRUPTERS

GROUND FAULT CIRCUIT INTERRUPTERS

JUNCTIONBOX

JUNCTIONBOX

TURBINE WITH GEYSAIR(FOR MIAPLUS®, MIAMULTI®)

TURBINE WITHOUT GEYSAIR(FOR MIAPLUS®, MIAMULTI®)

N LN L

ELECTRICAL DIAGRAM – THERMOMASSEUR

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

Page 23: Essencia - Installation manual

21 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

n

15A CIRCUIT

AIRSTREME(WARMTOUCHSHELL®)

N L N L

NEUTRAL N L LOAD

INMIX MODULE (CHROMATHERAPY)

GROUND FAULT CIRCUIT INTERRUPTERS

JUNCTIONBOX

N L

AROMACLOUD®

(AROMATHERAPY)

ELECTRICAL DIAGRAM - THERAPIES

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH

Page 24: Essencia - Installation manual

22

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

6"

10"

25,125"

68"

38"

25,125"

12"

14,5"

INTEGRATED waste & overflow

Standard waste & overflow

Wiring

Air pipe

Floor anchor

Floor anchor

Access trap

Ø6,5"

Opening for the Island Tub Drain

5,625"

68"

38"

INTEGRATED waste & overflow

1 PLUMBING – FLOOR LAYOUT FOR PIPES AND ACCESS

ESSENCIA 6838 - STANDARD WASTE INSTALLATION

ESSENCIA 6838 – ISLAND TUB DRAIN INSTALLATION (INTEGRATED OVERFLOW option ONLY)

NOTE : Please refer to the Installation Template provided with your ESSENCIA bath. However, if it is missing, please contact us at 1-800-463-2187 to order it.

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH

Page 25: Essencia - Installation manual

23 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

nPARTS & TOOLS REQUIRED

4,5"

19,5"

72"

36"

9,375"

10,5"

12"

WasteOverflowWiring

Air pipe Accesstrap

Floor anchor Floor anchor

41,5"

Ø6,5"

Opening for the Island Tub Drain

72"

36"

5,5"

1 PLUMBING – FLOOR LAYOUT FOR PIPES AND ACCESS (cont’d)

ESSENCIA OVAL 7236 - STANDARD WASTE INSTALLATION

ESSENCIA DESIGN – ISLAND TUB DRAIN INSTALLATION

NOTE : Please refer to the Installation Template provided with your ESSENCIA bath. However, if it is missing, please contact us at 1-800-463-2187 to order it.

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH

Page 26: Essencia - Installation manual

24

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

1 PLUMBING - ESSENCIA 6838 STANDARD DRAIN INSTALLATION

HELPFUL TIP:

• Carefully place the tub on its side, on a blanket or a corrugated cardboard.

Measure & Align (2x)

WARNING

• If necessary adjust length of the flexible overflow piping connected to the overflow.

STANDARD PARTS - PLUMBING ESSENCIA 6838

Anchor

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH

DESCRIPTION QTY

A Plated drain clicker (p. 3) 1

B Locking nut (p. 3) 1

C Strainer (p. 3) 1

D Rubber seal 1

E PVC Wired drain shoe 1

F PVC Piping 1-1/2’’ X 2’’ 1

G PVC Tee Connector 1-1/2’’ F-F 1

R

EFG

D

Flexible Overflow Piping (Factory installed)

Page 27: Essencia - Installation manual

25 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

nPARTS & TOOLS REQUIRED

Measure & Align (2x)

1 PLUMBING - ESSENCIA 6838 ISLAND TUB DRAIN INSTALLATION (INTEGRATED DRAIN & OVERFLOW OPTION)

HELPFUL TIP:

• Carefully place the tub on its side, on a blanket or a corrugated cardboard.

Measure & Align (2x)

Island Tub Drain

OPTIONAL PARTS - PLUMBING(1) ESSENCIA 6838

(1) : INTEGRATED DRAIN & OVERFLOW OPTION

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH

Anchor

DESCRIPTION QTY

H Plated drain clicker 1

I Strainer 1

J Rubber seal 1

K Brass drain shoe 1

L 4 in. brass tailpiece 1

M Nylon conic shaped seal for drain 1

N Brass nut 2

O Brass pipe 1-1/2” x 3” with flange 1

P Nylon flat seal with flange 1

Q 1-1/2” male threaded adaptor 1

WARNING

• Refer to supplied instructions for Island Tub Drain installation.

R

O N MPQ

J

L

K

Flexible Overflow Piping (Factory installed)

Page 28: Essencia - Installation manual

26

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

1 PLUMBING - ESSENCIA OVAL 7236

STANDARD DRAIN INSTALLATION

HELPFUL TIP:

• Carefully place the tub on its side, on a blanket or a corrugated cardboard.

Measure & Align (2x)

S

STANDARD PARTS - PLUMBING ESSENCIA OVAL 7236

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH

Threaded Anchor

DESCRIPTION QTY

A Plated drain clicker (p. 3) 1

B Locking nut (p. 3) 1

C Strainer (p. 3) 1

D Rubber seal 1

E PVC Wired drain shoe 1

F PVC Piping 1-1/2’’ X 2’’ 1

G PVC Tee Connector 1-1/2’’ F-F 1

WARNING

• If necessary adjust length of the flexible overflow piping connected to the overflow.

• Adjust length on the straight part of the brass overflow pipe « F » to fit with the drain position that varies with different bath models.

• Fix anchors « S » to floor with the provided screws « V » (p. 4).

EFG

D

Flexible Overflow Piping (Factory installed)

Page 29: Essencia - Installation manual

27 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

n

1 PLUMBING - ESSENCIA DESIGN

ISLAND TUB DRAIN INSTALLATION

HELPFUL TIP:

• Carefully place the tub on its side, on a blanket or a corrugated cardboard.

Measure & Align (2x)

Island Tub Drain

WARNING

• Fix anchors « S » to floor with the provided screws « V » (p. 4).

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH

Threaded Anchor

WARNING

• Refer to supplied instructions for Island Tub Drain installation.

(1) : INTEGRATED DRAIN & OVERFLOW OPTION

DESCRIPTION QTY

H Plated drain clicker 1

I Strainer 1

J Rubber seal 1

K Brass drain shoe 1

L 4 in. brass tailpiece 1

M Nylon conic shaped seal for drain 1

N Brass nut 2

O Brass pipe 1-1/2” x 3” with flange 1

P Nylon flat seal with flange 1

Q 1-1/2” male threaded adaptor 1

STANDARD PARTS - PLUMBING(1) ESSENCIA DESIGN

S

O N MPQ

J

L

K

Flexible Overflow Piping (Factory installed)

Page 30: Essencia - Installation manual

28

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

WARNING IF THE AIR PIPING CONNECTIONS AND POWER SUPPLY OF THERAPEUTIC OPTIONS HAVE TO BE AT FLOOR LEVEL, YOU MUST MAKE AN OPENING ON ONE SIDE OF THE BATH, AS CLOSE AS POSSIBLE TO TURBINE AND CONTROLS.

• Do not drill through the interior shell.

• The size of the opening must be large enough to allow wires and pipes to go through.

Drill

1/4 in. drill bit

Jig saw with fine cut blade

ESSENCIA 6838

ESSENCIA Oval 7236 & DESIGN

(*) : Location of air pipe can differ from drawing.

• Air pipe*

• Geysair (optional)

• Electric cables (Optional therapies)

• Air pipe*

• Geysair (optional)

• Electric cables (Optional therapies)

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH

2 TURBINE & GEYSAIR INSTALLATION (FOR THERMOMASSEUR®)

PASSAGE FOR THE ELECTRICAL WIRING OF OPTIONAL THERAPIES

TOOLS REQUIRED

Page 31: Essencia - Installation manual

29 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

n

2 TURBINE & GEYSAIR INSTALLATION (FOR THERMOMASSEUR®)

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH

WARNING

• Access to GeysairTM backflow preventer is necessary for cleaning of the filter.

• Baths from Essencia™ collection cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models.

• Geysair component cannot be remote mounted. It must stay at original position, attached to bath. Must never be unplugged.

TURBINE REMOTE MOUNTING

SEE STEP 7 page 17

Geysair Hose and Back Flow Preventer

Hot Water Supply

1-1/2 I.D. PVC AIR INTAKE PIPE («TIGERFLEX®» FLEXIBLE PVC)

1-1/2 I.D. ABS, PVC PIPE (RIGID or «TIGERFLEX») & Fittings (not included)

3 ELECTRICAL WIRING OF OPTIONAL COMPONENTS

REMOTE MOUNTING of CONTROL MODULES

SEE STEP 8 page 18

Page 32: Essencia - Installation manual

30

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

4 BATH INSTALLATION - ESSENCIA 6838 WITH ISLAND TUB DRAIN (INTEGRATED OVERFLOW OPTION ONLY)

HELPFUL TIPS:

• Carefully place the tub on its side, on a blanket or a corrugated cardboard.

• To easily manipulate the bathtub in a safe way during installation, we recommend using moving straps.

R

Anchor R Measure & Align (2x)

WARNING

• Be sure the floor is leveled. Use shims as needed.

• Do not remove the protective plastic film on the tub and place a drop-cloth in the tub during installation to protect the acrylic.

• Apply a bead of silicone around the perimeter of the bath once on the floor.

• Connect the drain.

• Install bath on anchors « R » previously screwed to the floor. Remove exceeding silicone.

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH

4 BATH INSTALLATION - ESSENCIA 6838 WITH STANDARD DRAIN ..........................................13

Page 33: Essencia - Installation manual

31 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

n

4 BATH INSTALLATION : ESSENCIA DESIGN WITH ISLAND TUB DRAIN

HELPFUL TIPS:

• Carefully place the tub on its side, on a blanket or a corrugated cardboard.

• To easily manipulate the bathtub in a safe way during installation, we recommend using moving straps.

S

S

Threaded anchor

T

U

W

S

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH

Measure & Align (2x)

Threaded anchor

WARNING • Be sure the floor is leveled. Use shims as needed.• Do not remove the protective plastic film on the tub and place a drop-cloth in the tub during installation to protect the acrylic. • Apply a bead of silicone around the perimeter of the bath.• Connect the drain.• Install bath on anchors « S » previously screwed to the floor. Remove exceeding silicone.• Attach the bath to floor with washers « U » and nuts « T » screwed to anchors « S ».• Cover with seals « W ».

4 BATH INSTALLATION - ESSENCIA OVAL 7236 WITH STANDARD DRAIN ...............................14

Page 34: Essencia - Installation manual

32

ESSE

NC

IA® -

in

sta

lla

tio

n

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

4 BATH INSTALLATION

DRAIN CONNECTION WITH ISLAND TUB DRAIN® (ITD) - INFORMATION

WARNING

• Refer to supplied instructions for ISLAND TUB DRAIN® installation.

ISLAND TUB DRAIN®

Floor surface

WARNING

Use the 6 in. (15 cm) tail piece supplied with Island Tub Drain®

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH

Page 35: Essencia - Installation manual

33 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA® COLLECTION

INSTALLATION INSTRUCTIONS

ESSE

NC

IA® -

in

sta

lla

tio

n

5 ELECTRONIC CONTROL INSTALLATION – MIAPLUS® & MIAMULTI® (6838 & OVAL 7236) ...............................15

5 ELECTRONIC CONTROL INSTALLATION – DOT (THERAPIES) .........................................................................15

6 REMOTE MOUNTING OF TURBINE ..............................................................................................................16

7 REMOTE MOUNTING OF TURBINE – AIR PIPE (THERMOMASSEUR®) ..............................................................17

7 REMOTE MOUNTING OF TURBINE – ELECTRICAL CONNECTIONS (THERMOMASSEUR®) ................................17

8 REMOTE MOUNTING OF TURBINE – ELECTRICAL CONNECTIONS OF OPTIONAL THERAPIES .........................18

8 REMOTE MOUNTING OF OPTIONAL THERAPIES (TUB ONLY) – ELECTRICAL CONNECTIONS ..........................19

ELECTRICAL DIAGRAM – THERMOMASSEUR ................................................................................................20

ELECTRICAL DIAGRAM – THERAPIES ...........................................................................................................21

FOR THE NEXT STEPS, SEE SECTION : REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER THE BATH

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH

Page 36: Essencia - Installation manual

CU

TT

ING

TE

MP

LA

TE

s /

GA

BA

RIT

S D

E P

ER

ÇA

GE

NOKORI

CUTTING TEMPLATES / GABARITS DE PERÇAGE

NOKORI

CUTTING TEMPLATES / GABARITS DE PERÇAGE

1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © August 2016 BainUltra Inc. All rights reserved. 45200640

www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

34

11.313"[28.7 cm]

1.063"[2.7 cm]

R0.125"[R0.3 cm]

0.813"[2.1 cm]

11.063"[28.1 cm]

1.625"[4.1 cm]

1.125"[2.9 cm]

1.375" [3.5 cm]

0.875"[2.2 cm]

R0.125"[R0.3 cm]

1.625"±0.04"[4.1 cm±0.1 cm]

5.125"±0.04"[13.0 cm±0.1 cm]

R0.250"[R0.6 cm]5.591" [14.2 cm]

Control cut-outTrou du contrôle

Control outlineContour du contrôle

2.165"[5.5 cm]

AIR INTAKE - OPENING

PRISE D'AIR - OUVERTURE

MIAPLUS & MIAMULTI

Trou pour infrarouge MiaMulti®Cut-out for MiaMulti® infrared

11.313"[28.7 cm]

1.063"[2.7 cm]

R0.125"[R0.3 cm]

0.813"[2.1 cm]

11.063"[28.1 cm]

1.625"[4.1 cm]

1.125"[2.9 cm]

1.375" [3.5 cm]

0.875"[2.2 cm]

R0.125"[R0.3 cm]

1.625"±0.04"[4.1 cm±0.1 cm]

5.125"±0.04"[13.0 cm±0.1 cm]

R0.250"[R0.6 cm]5.591" [14.2 cm]

Control cut-outTrou du contrôle

Control outlineContour du contrôle

2.165"[5.5 cm]

AIR INTAKE - OPENING

PRISE D'AIR - OUVERTURE

MIAPLUS & MIAMULTI

Trou pour infrarouge MiaMulti®Cut-out for MiaMulti® infrared

11.313"[28.7 cm]

1.063"[2.7 cm]

R0.125"[R0.3 cm]

0.813"[2.1 cm]

11.063"[28.1 cm]

1.625"[4.1 cm]

1.125"[2.9 cm]

1.375" [3.5 cm]

0.875"[2.2 cm]

R0.125"[R0.3 cm]

1.625"±0.04"[4.1 cm±0.1 cm]

5.125"±0.04"[13.0 cm±0.1 cm]

R0.250"[R0.6 cm]5.591" [14.2 cm]

Control cut-outTrou du contrôle

Control outlineContour du contrôle

2.165"[5.5 cm]

AIR INTAKE - OPENING

PRISE D'AIR - OUVERTURE

MIAPLUS & MIAMULTI

Trou pour infrarouge MiaMulti®Cut-out for MiaMulti® infrared

Print scale 100% / Imprimer à 100%

Print scale 100% / Imprimer à 100%

Print scale 100% / Imprimer à 100%