ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module...

19
LNK TM Ready ESP-ME3 Controller Advanced User Manual

Transcript of ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module...

Page 1: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

LNKTM Ready

ESP-ME3 ControllerAdvanced User Manual

Page 2: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller2

EN ESP-ME3 Controller · Advanced User Manual

Technical SupportQuestions?

Call Rain Bird toll free Technical Support at 1-800-724-6247 (USA and Canada only)

Hazardous Warnings

CWARNINGIndicates a hazardous situation that, if not avoided, could result in death or serious injury.

CCAUTIONIndicates a hazardous situation that, if not avoided, could result in minor or moderate injury.

NOTICEIndicates information considered important, but not hazard-related (e.g., messages relating to property damage).

SAFETY INSTRUCTIONSSpecific safety-related instructions or procedures are described.

Symbols & User Operation

aNUMBERS define a series of steps for the user to follow in order to operate the controller.

B NOTE: Notifies the user of important operating instructions related to controller functionality, installation or maintenance.

H REPEAT: Indicates that a repetition of previous steps or actions may be required for further oper-ation, or to complete a process.

ContentsTechnical Support ......................................................... 2

Introduction ..................................................3Welcome to Rain Bird® ................................................. 3

The Intelligent Use of Water® .........................................3

ESP-ME3 Controller Features ...................................... 3WiFi Enabled .........................................................................3

Installation ...................................................4Mount Controller .......................................................... 4

Connect Valves ....................................................................4Connect Master Valve (optional) ...................................4Connect Pump Start Relay (optional) ..........................5Connect Flow Sensor (optional) ....................................5Connect Weather Sensor (optional) .............................6Connect Power ....................................................................6

Station Expansion Modules ........................................ 7Install Modules ....................................................................7Station Numbering ............................................................8

Complete Controller Installation ............................... 8

Normal Operation ........................................8Controls and Features .................................................. 8

AUTO .......................................................................................9OFF ...........................................................................................9

Display Indicators ......................................................... 9

Basic Programming ....................................101. Set Date and Time .................................................. 10

2. Set Watering Start Times ...................................... 10

3. Set Station Run Times ........................................... 10

4. Set Water Days ........................................................ 10Custom Days of the Week ............................................. 10

Program-Based Scheduling ...................................... 11Common Programming Error ..................................... 11

Manual Watering Options ..........................11Test All Stations ........................................................... 11

Run a Single Station ................................................... 11

Run a Single Program ................................................ 12

Advanced Programming ............................12Odd or Even Calendar Days ...................................... 12

Cyclic Days .................................................................... 12

Seasonal Adjust ........................................................... 13

Delay Watering ............................................................ 13

Permanent Days Off ................................................... 13

Special Features..........................................14Options .......................................................14

Reset Button ................................................................ 14

Remote Accessories .................................................... 14

Detached Programming ............................................ 15

Battery Life ................................................................... 15

Appendix .....................................................15Troubleshooting ......................................................... 15

Error Detection ................................................................. 15Programming Errors (blinking LED) .......................... 15Electrical Errors (non-blinking LED) .......................... 15Flow Alarms ....................................................................... 16Watering Issues................................................................. 16Electrical Issues (solid LED illuminated)................... 17

Certifications ............................................................... 18

Safety Information ..................................................... 18

Page 3: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller3

EN IntroductionWelcome to Rain Bird®

Thank you for choosing Rain Bird’s ESP-ME3 controller. In this manual are step by step instructions for how to install and operate the ESP-ME3.

The Intelligent Use of Water®We believe it is our responsibility at Rain Bird to develop products that use water efficiently.

ESP-ME3 Controller Features

Feature DescriptionMaximum Stations 22 (with optional Station

Modules)Master Valve or Pump Start Relay

Supported

Start Times 6Programs 4Program Cycles Custom Days, Odd, Even and

CyclicPermanent Days Off By programMaster Valve Control On/Off per stationRain Delay SupportedRain/Freeze Sensor SupportedRain Sensor Control Global or by stationSeasonal Adjust Global or by programManual Watering Run YesManual Program Run YesManual Test All Stations YesShort Detect YesDelay Between Stations Set by programAccessory Port Yes (5 pin)Save & Restore Program-ming

Yes

Station Advance YesLNKTM WiFi Module SupportedFlow Sensor SupportedCycle+SoakTM Supported in Rain Bird App

via LNKTM WiFi Module

WiFi EnabledThe LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3 Controller using an Apple® iOS® or AndroidTM compatible smart device. The mobile appli-cation allows remote access and configuration of one or more irrigation controllers.

* Apple is a trademark of Apple Inc, IOS is a trademark of Cisco Systems Inc, and Android is a trademark of Google LLC.

For more information on the LNKTM WiFi Module and the value this product can provide for your ESP-ME3 controller, please visit: http://wifi-pro.rainbird.com

LNKTM WiFi Module (sold separately)

Manage Sites Remotely

Page 4: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller4

EN InstallationMount Controller

B NOTE: Choose a suitable mounting location close to a 120VAC wall outlet.

aDrive a mounting screw into the wall, leaving an 1/8 inch gap between the screw head and the wall surface (use the supplied wall anchors if necessary), as shown.

bLocate the keyhole slot on back of the controller unit and hang it securely on the mounting screw.

1/8 IN.

a b

cOpen the front panel, and drive three additional screws through the open holes inside the controller and into the wall, as shown.

c

a

b

MASTER VALVE

COMCOM

MVMV

11

22

SENSSENS

e c

Connect Valves

aRoute all field wires through the opening at the bottom or back of the unit. Attach conduit if desired, as shown.

CWARNINGDo not route valve wires through the same opening as power wires.

bConnect one wire from each valve to the terminal on the Base Module or Station Module that corresponds to the desired station number (1-22).

cConnect a field common wire to the COM (common)terminal on the Base Module. Then connect the remaining wire from each valve to the field common wire, as shown.

dTo perform a Valve Test, connect the common wire to the COM terminal and the power wire to the VT terminal. This will immediately turn the valve ON.

Connect Master Valve (optional)

eConnect a wire from the master valve to the MV (master valve) terminal on the Base Module. Then connect the remaining wire from the master valve to the field common wire, as shown.

Page 5: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller5

EN Connect Pump Start Relay (optional)

aConnect a wire from the PSR (pump start relay) to the MV (master valve) terminal on the Base Module. Then connect another wire from the pump start relay to the field common wire, as shown.

bTo avoid the possibility of damage to the pump, connect a short jumper wire from any unused terminal(s) to the nearest terminal in use, as shown.

NOTICEThe ESP-ME3 controller DOES NOT provide power for a pump. The relay must be wired according to manu-facturer instructions.

Only the following Rain Bird pump start relay models are compatible with the ESP-ME3:

Description Note Model No.

Universal Pump Relay 110 volt only

PSR110IC

Universal Pump Relay 220 volt only

PSR220IC

Connect Flow Sensor (optional)

B NOTE: Install the flow sensor in the field accord-ing to the manufacturer’s instructions.

aRun the flow sensor wires to the controller.

CWARNINGDo not route valve wires through the same open-ing as power wires.

bConnect both flow sensor wires to the Flow terminals, as shown. Be sure to connect the positive (sometimes red) sensor wire to the red (+) terminal and the negative (sometimes black) sensor wire to the grey (-) terminal.

b

Flow Sensor Settings

Set the controller to obey or ignore a flow sensor.

When set to Sensor ON, automatic irrigation will be suspended per station if detected flow exceeds learned flow by more than 30%. When set to Sensor OFF, all stations will ignore the flow sensor.

Turn the dial to Flow Sensor.

• Press or to select SENS ON (sensor on) or SENS OFF (sensor off).

Sensor ON Sensor OFF Flow detected (flashing)

B NOTE: When switching from Sensor OFF to Sen-sor ON, the controller will begin to LEARN FLOW. It will run each station for short period to set the expected station flow.

B NOTE: See Troubleshooting section of the Appen-dix for Flow Alarms information.

a B NOTE: Connection to pump and external power not shown. Refer to pump instal-lation instructions.

PUMP START RELAY

b

COMCOM

PSRPSR

11

22

Page 6: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller6

EN Connect Weather Sensor (optional)

aRemove the yellow jumper wire from the SENSOR terminals on the controller.

NOTICEDo not remove the yellow jumper wire unless con-necting a rain sensor.

bConnect both rain sensor wires to the SENSOR terminals as shown.

CWARNINGDo not route the rain sensor wires through the same opening as the power wiring

B NOTE: Rain Bird ESP-ME3 controllers are only compatible with normally closed rain sensors.

B NOTE: For wireless rain/freeze sensors, refer to the sensor installation instructions.

b

Connect Power

CWARNINGDO NOT plug in the transformer or connect external power until you have completed and checked all wiring connections.

Installation with Pre-attached Cord

• Plug the attached power cord into a nearby 120VAC electrical outlet.

Weather Sensor Settings

Set the controller to obey or ignore a weather sensor.

When set to Sensor ON, automatic irrigation will be suspended if rainfall is detected. When set to Sensor OFF all stations will ignore the rain sensor.

Turn the dial to Weather Sensors.

• Press or to select SENS ON (sensor on) or SENS OFF (sensor off).

Sensor ON Sensor OFF Rain detected (flashing)

Page 7: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller7

EN Outdoor Installation with Direct Wiring

CWARNINGElectric shock can cause severe injury or death. Make sure power supply is turned OFF before connecting power wires.

POWER WIRING CONNECTIONS 120VACBlack supply wire (hot) to the black transformer wire

White supply wire (neutral) to the white transformer wire

Green supply wire (ground) to the green transformer wire

aLocate the transformer wiring compartment in the lower left corner of the controller unit. Use a screwdriver to remove the cover and expose the transformer connection wires.

bRoute the three external power source wires through the conduit opening at the bottom of the unit and into the wiring compartment.

cUsing the provided wire nuts, connect the external power source wires (two power and one ground) to the transformer connection wires inside the wiring compartment.

CWARNINGGround wire must be connected to provide electrical surge protection. Permanently mounted conduit shall be used for connecting main voltage to the controller

dVerify that all wiring connections are secure, then replace the wiring compartment cover and secure it with the screw.

a

c

b

Station Expansion ModulesOptional Station Modules can be installed in the empty slots to the right of the Base Module to increase the station capacity up to 22 stations.

B NOTE: 6-Station Modules are compatible with ESP-ME3 and ESP-Me. They are not backwards compatible with the ESP-M vintage controller.

B NOTE: For ideal station sequencing, insert 3-Sta-tion module after inserting all 6-station modules. For more details see the Station Numbering sec-tion.

3-STATION(ESPSM3) 6-STATION

(ESPSM6)

Expansion Modules(sold separately)

Base Module(included)

Install Modules

aVerify the securing lever on the module is in the unlocked position (slide to the left).

bPlace the module under the desired slot between the plastic rails.

cPush the module up into the slot until secure.

dSlide the securing lever to the locked position (slide to the right).

bcda

H REPEAT for additional modules.

B NOTE: Modules can be installed or removed with OR without AC power connected. They are con-sidered “hot-swappable”.

B NOTE: It take about 30 seconds for stations to become available for configuration after install-ing a new module.

Page 8: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller8

EN Station NumberingThe controller is configured with “fixed station num-bering”, meaning that Bays Two, Three and Four can accept either a 3 or a 6-Station Module. If a 6-Station Module is NOT installed then the unused stations are reserved for future use.

Example of Station Numbering when using two 3-Station Modules. A total of 10 stations are installed.

Bay One Bay Two Bay Three Bay Four

• The Base Module is installed in Bay One and uses Stations 1 through 4.

• A 3-Station Module is installed in Bay Two and uses stations 5 through 7. Stations 8 through 10 are skipped and will be unavailable.

• A 3-Station Module is installed in Bay Three and uses stations 11 through 13.

During programming, the controller will skip any unused stations, creating a gap in station numbering. The unused stations will show on the display as 8SKIP, 9SKIP, etc.

If the screen displays 20NOMOD where the 20 is flash-ing, then there is no module installed for that station number.

Complete Controller InstallationaReinstall and reconnect the front panel.

bApply power to the controller and test the system.

B NOTE: The electrical connections can be checked even if water is not available. If water is available and you would like to test some or all of your stations, use the Test All Stations feature of the controller.

Normal OperationControls and Features Program

Select ButtonSelect Program

A, B, C or D

Start TimesUp to 6 Start

Times per program

Run TimesSet station Run Times

Manual WateringStart watering for one or all stations

Weather SensorsSet controller to obey or ignore a weather sensor

Seasonal AdjustAdjust Run Times

from 5% up to 200% Back/Next Buttons

Select programming

options

– / + ButtonsAdjust feature

settings

OFFDisables automatic

irrigation

AUTOWatering occurs

automatically

Date/TimeSet the current Date and Time

ALARMIndicator

Hold to StartManual

irrigation

Water DaysSelect days to

allow watering

Flow SensorSet the controller to

obey or ignore a flow sensor

Page 9: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller9

ENAUTO

AUTO is the normal operating mode. Return the dial to AUTO when programming is complete.

During Watering:

The display shows a blinking sprinkler symbol, the active Station Number or Program, and the Remaining Run Time.

• To cancel watering, turn the dial to OFF for three seconds until the screen shows OFF.

To Manually Start a Program:

aPress the Program Select button to select a program.

bPress and hold the Hold to Start button to immediately start manual watering for the selected program.

OFF

Turn the dial to OFF to stop automatic irrigation or to cancel all active watering immediately.

NOTICEWatering will NOT occur if the controller remains in the OFF position.

B NOTE: Manual watering can be started using mobile apps or LIMR when dial is in OFF position.

Display Indicators

Display Func-tion

Description

ALL ALL All stations

CLEARED CLEAREDProgramming was cleared

CYCLIC CYCLICWatering occurs at specific intervals, such as every 2 days

DELAY DELAY Delay Watering Active

EVEN EVEN Even days watering

FLOW FLOW Flow Sensor

MV ON MV ONMaster or Pump-start relay is active

NOMOD NOMOD No station modules installed for that station

ODD ODD Odd days watering

OFF OFFController will not water

PERMOFF PERMOFFPermanent days off for Odd, Even, Cyclic watering

RAIN RAIN Rain Sensor

RESTORD RESTORD Programming restored

SAVED SAVED Save programming

SENS ON SENS ONSensor will function if wired

SEN OFF SEN OFFSensor is ignored even if wired

SKIP SKIP Station not used due to station module config-uration

SOAK SOAK

Soak time between wa-tering times - support-ed through the Rain Bird app.

Page 10: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller10

EN Basic Programming1. Set Date and Time

Turn the dial to Date / Time

aPress or to select the setting to change.

bPress or to change the setting value.

cPress and hold or to accelerate adjustments.

To change the time format (12 hour or 24 hour):

dWith Day of Month blinking, press .

ePress or to select the desired time format, then press to return to the time setting.

2. Set Watering Start TimesUp to six Start Times are available for each program.

Turn the dial to Start Times

aPress Program Select to choose the desired Program (if necessary).

bPress or to select an available Start Time.

cPress or to set the selected Start Time (ensure the AM/PM setting is correct).

dPress to set additional Start Times.

eTo turn off a start time press until 12:00 AM (00:00 in 24 HR), then press one more time for OFF.

B NOTE: The OFF Position for any start time is between 11:45 PM and 12:00 AM.

3. Set Station Run TimesRun Times can be set from one minute up to six hours.

Turn the dial to Run Times

aPress Program Select to choose the desired Program (if necessary).

bPress or to select a Station.

cPress or to set the Run Time for the selected Station.

dPress to set additional Station Run Times.

B NOTE: Only assign Run Times in a Program for stations you want to water. If you do not want a specific station to run in a selected program then set the Run Time to zero.

B NOTE: Rain Bird recommends that the maximum irrigation station cycle time be less than the time required for runoff to begin and that there be adequate soak time before the next irrigation cycle of that same station begins again.

4. Set Water DaysCustom Days of the Week

Set watering to occur on specific days of the week.

Turn the dial to Water Days

aPress Program Select to choose the desired Program (if necessary).

bPress or to set the selected (blinking) day as either ON or OFF, and to automatically move to the next day.

cPress or at any time to move the cursor to the previous or next day.

B NOTE: With Sunday selected, press the button to enter and activate Cyclic Watering (see the Advanced Programming section). If this is not desired, press the button to return to watering by Custom Days.

Page 11: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller11

EN Program-Based SchedulingThe ESP-ME3 uses a programmed-based scheduling method to create irrigation schedules. This means all stations with a run time on the program will run in numerical order.

Common Programming ErrorThe most common programming error for any pro-gram-based controller is to set multiple Program Start Times that cause watering cycles to repeat.

As an example: Program A has a 1st Start Time set to run at 8:00 AM. But then a 2nd Start Time has mistak-enly been set for 8:15 AM, which means that all sta-tions would water a 2nd time.

In this example, a 3rd Start Time has mistakenly been set for 8:30 AM. Which means all stations would water a 3rd time. The desired watering time was 45 minutes, or 15 minutes per station. The actual is 2 hours and 15 minutes, which is excessive watering!

Incorrect: Multiple Start Times set by mistake

Program Letter

Program Watering

Time

Program Start Time

Station Number

Station Watering Duration

A 1st 8:00 AM1 15 MIN2 15 MIN3 15 MIN

A 2nd 8:15 AM1 15 MIN2 15 MIN3 15 MIN

A 3rd 8:30 AM1 15 MIN2 15 MIN3 15 MIN

Correct: Only one Start Time

Program Letter

Program Watering

Time

Program Start Time

Station Number

Station Watering Duration

A 1st 8:00 AM

1 15 MIN2 15 MIN3 15 MIN4 15 MIN

Manual Watering OptionsTest All Stations

Start watering immediately for all programmed stations.

Turn the dial to Manual Watering

aPress or to set a Run Time.

bPress the Hold to Start button.

cTurn the dial to AUTO after display shows STARTED.

During Testing:

The display shows a blinking sprinkler symbol, the active Station Number and the remaining Run Time.

dTo cancel the test, turn the dial to OFF for three seconds until the screen shows OFF.

Run a Single StationStart watering a single station, or set multiple stations to water in order.

Turn the dial to Manual Watering

aPress or to select the desired station.

bPress – or + to set a Run Time.

cPress the Hold to Start button.

dIrrigation will begin and STARTED will appear on the display.

eTurn the dial back to AUTO

H REPEAT process as desired to add more stations to the queue. When one station finishes watering then the next station will start.

B NOTE: Manual Watering (Test All, Run Single Sta-tion and Manual Program) will start even when a weather sensor is set to SENS ON (sensor on).

Page 12: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller12

EN Run a Single ProgramStart watering immediately for one program.

Turn the dial to AUTO.

aPress Program Select to choose the desired Program (if necessary).

bPress the Hold to Start button to begin watering the selected Program.

cIrrigation will begin and STARTED will appear on the display.

dPress the Advance Station button to advance to the next station if desired.

eNOTE: A maximum of 88 stations can be queued across all four programs.

During Manual Watering (Single-station or Single-program):

The display shows a blinking sprinkler symbol, the active Station Number, and the remaining Run Time.

• To cancel manual watering, turn the dial to OFF for three seconds until the screen shows OFF.

To add additional programs to the manual watering queue:

Turn the dial to Manual Watering

aPress and hold Program Select to show program letter on the display.

bPress Program Select to choose the desired program (if necessary).

cPress the Hold to Start button to begin watering the selected program.

dTurn the dial to AUTO

Advanced ProgrammingOdd or Even Calendar Days

Set watering to occur on all ODD or EVEN calendar days.

Turn the dial to Water Days

aPress Program Select to choose the desired Program (if necessary).

bPress and hold and until ODD or EVEN is displayed.

Cyclic DaysSet watering to occur at specific intervals, such as every 2 days, or every 3 days, etc.

Turn the dial to Water Days

aPress Program Select to choose the desired Program (if necessary).

bOn the Custom Days of the Week screen, press until the Cyclic screen is displayed (after SUN).

cPress or to set the desired DAY CYCLE, then press .

dPress or to set the DAYS REMAINING before the cycle begins. The NEXT watering day updates on the display to indicate the day that watering will start as shown.

B NOTE: See Special Features to set Rain Sensor ON by Station.

Page 13: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller13

EN Seasonal AdjustIncrease or decrease program run times by a selected percentage (5% to 200%).

As an example: If the Seasonal Adjust is set to 100% and the station Run Time is programmed for 10 min-utes, the station will run for 10 minutes. If the Seasonal Adjust is set to 50%, the station will run for 5 minutes.

Turn the dial to Seasonal Adjust.

aPress or to increase or decrease Seasonal Adjust for all Programs.

bTo adjust an individual Program, press Program Select to choose the desired Program (if necessary). Press or to increase or decrease Seasonal Adjust for all Programs.

Delay WateringSuspend watering for up to 14 days.

Turn the dial to AUTO.

aPress and Hold the button to enter the Rain Delay screen.

bPress or to set the DAYS REMAINING. The NEXT watering day will update on the display to indicate when watering will resume.

cTo cancel a Rain Delay, set the DAYS REMAINING back to 0.

B NOTE: When the delay expires, automatic irriga-tion resumes as scheduled.

Permanent Days OffPrevent watering on selected days of the week (for Odd, Even or Cyclic programming only).

Turn the dial to Water Days

aPress Program Select to choose the desired Program (if necessary).

bPress and hold Program Select, then press to set the selected (blinking) day as a Permanent Day Off or press to leave the day ON.

Page 14: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller14

EN Special FeaturesaTurn the dial to the desired position indicated

below for each Special Feature.

bPress and hold and at the same time.

Set Interstation Delay by Program

A station delay (from 1 second to 9 hours) ensures that a valve has completely closed before the next one

opens. Press Program Select to set delay for different

programs.

Set Rain Sensor by Station

Tells a station to obey or ignore a rain sensor.

Save Programming

Restore Programming

Set Master Valve by Station

Allows a station to be controlled by a master

valve or pump start relay.

Set to Odd or Even Watering Days

Options Reset Button

If the controller is not working properly, you can try pressing RESET.

• Insert a small tool such as a paper clip, into the access hole and press until the controller is reset. All previously programmed watering schedules will remain stored in memory.

RESET

Remote AccessoriesA 5 pin accessory port is available for Rain Bird approved external devices, including:

• LNKTM WiFi Module

• LIMR Receiver Quick Connect harnessPORT

Set Flow Sensor by Station

Turns a flow sensor on or off by station

Reset to Factory DefaultsAll programmed schedules

will be erased.

Page 15: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller15

EN Detached ProgrammingProgram the front panel remotely on battery power.

The front panel can be removed from the controller and programmed remotely using a 9 volt battery for power. Settings can be programmed for all 22 stations regardless of which Station Modules are installed in the controller.

aRemove the front panel.

bInstall a 9V battery in the battery compartment.

cProgram the controller.

B NOTE: Program information is stored in nonvol-atile memory so it is never lost if the front panel loses power.

dReplace the front panel (refer to Complete Installation in the Installation section).

B NOTE: After the front panel is re-installed, any station that does not have a corresponding Sta-tion Module installed will function as though the run time is zero.

Battery LifeIf the display repeatedly shows “-- -- -- -- --”, or there is no display when using a 9V battery for remote pro-gramming, replace the battery.

AppendixTroubleshootingError Detection

The ESP-ME3 controller has built-in error detection that can automatically generate an ALARM caused by an essential programming error or if an electrical short condition is detected.

The ALARM LED light on the ESP-ME3 controller front panel will light up to indicate an alarm condition:

Programming Errors (blinking LED)

ErrorALARM

LED

Error Mes-sage On Display

No Start Times are set BLINK NO START TIMES

No Run Times are set BLINK NO RUN TIMES

No Water Days are set BLINK NO WATER DAYS

The error will go away when the station is successfully run after condition is corrected.

B NOTE: The dial must be in the AUTO position for an ALARM message to appear on the display.

Electrical Errors (non-blinking LED)

ErrorALARM

LEDError Message

On DisplayMaster Valve short

SOLID MASTER VALVE SHORTED OR HIGH CURRENT

Station short SOLID STATION “X” WIRE SHORT-ED

When an electrical error is detected, irrigation for the affected station is cancelled and watering advances to the next operable station in the program.

The controller will attempt to water the affected sta-tion again at the next scheduled watering. Completion of a successful watering will clear the error condition associated with that station.

Page 16: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller16

EN

Watering Issues

Problem Possible Cause Possible SolutionDisplay shows a program is active, but system isn’t watering.

Water source not supplying water. Verify there is no disruption to the main water line and that all other water supply lines are open and functioning properly.

Wiring is loose or not properly connect-ed.

Check that field wiring and master valve or pump start relay wiring is securely connected at the controller and in the field.

Field wires are corroded or damaged. Check field wiring for damage and replace if necessary. Check wiring connections and replace with watertight splice connectors if needed.

Loss of AC power. When there is a power loss and a 9 volt battery is in-stalled, the system does not irrigate but programs show as remaining active.

NO AC message on display.

No Power detected. Check circuit breaker and that unit is plugged into socket or properly connected to power source.

Controller may be plugged into a GFCI outlet or an outlet that is wired to a GFCI outlet.

Check power to the outlet or reset the circuit breaker.

It just rained and the alarm light is not illuminated, why?

This is normal operation. The ESP-ME3 does not consider the interruption of irrigation due to rainfall as an alarm condition.

This is normal operation.

Flow Alarms

ErrorALARM

LEDError Message

On DisplayFlow Sensor - High Flow Con-dition

Solid HIGH FLOW ALARM STA-TION "X"

Flow Sensor - Low Flow Con-dition

Solid LOW FLOW ALARM STA-TION "X"

When a flow sensor is in use the ESP-ME3 monitors for High Flow of 130% above regular learned flow. This percent limit can be adjusted in the Rain Bird App when used with LNKTM WiFi Module. If a High Flow con-dition is detected, a “High Flow Alarm” is shown at the display and the red alarm LED comes on. To clear the alarm press the “Hold to Start” right arrow button dur-ing the alarm message.

Low Flow conditions are also monitored. The limit for Low Flow is 70% below the learned flow unless changed in the Rain Bird App. A Low Flow alarm is shown at the controller display and the red alarm LED comes on.

To clear the alarm press the “Hold to Start” right arrow button during the alarm message.

B NOTE: Turning the flow sensor feature off and then back on will cause the controller to learn new flow levels and ignore previous error condi-tions.

B NOTE: If the flow sensor measures flow when the controller is not scheduled for watering, a “HIGH FLOW ZONE” alarm is shown on the display and the red alarm LED comes on. To clear the alarm press the “Hold to Start” right arrow button dur-ing the alarm message.

Page 17: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller17

EN Watering Issues

Problem Possible Cause Possible SolutionProgrammed sched-ules do not start.

Connected rain sensor may be activat-ed.

Set Rain Sensor to Sensor OFF to ignore the rain sensor. If watering resumes, the sensor is operating properly and no further correction is needed.

Connected rain sensor may not be oper-ating properly.

Let the rain sensor dry out, or disconnect it from the controller terminal strip and replace it with a jumper wire connecting the two SENS terminals, or set to Sensor OFF.

If no rain sensor is connected, the jumper wire connecting the two SENS terminals on the terminal strip may be missing or damaged.

Move dial position to Weather Sensors and set to Sensor OFF.

Too much irrigation Multiple Start Times in the same pro-gram.

Separate start times are not required for each valve. A program only requires single start time in order to run all stations in that program.

Multiple programs are running at the same time.

Review programming to assure that the same Station is not active in multiple Programs.

Valve is malfunctioning. Check to see if the ALARM light on the controller is lit solid, then repair or replace the valve if necessary.

Seasonal Adjust setting is too high. Set Seasonal Adjust to 100%.

Electrical Issues (solid LED illuminated)

Problem Possible Cause Possible SolutionDisplay is blank or fro-zen, the controller will not accept program-ming or is operating abnormally.

Power not reaching the controller.

Verify the main AC power supply is securely plugged in or connect-ed and working properly.

Controller needs to be reset. Press the Reset Button. For details see “Reset Button” section.

An electrical surge may have interfered with the control-ler’s electronics.

Unplug the controller for 2 minutes, then plug it back in. If there is no permanent damage, the controller should accept programming and resume normal operation.

Automatic error detec-tion indicates a problem by ALARM LED and an error message on display.

Short circuit or overload condition in valve, master valve or pump start relay wiring.

Identify and repair the fault in the wiring. Refer to compatible pump start relays. For details see “Connect Pump Start Relay” section.

LED is flashing or solidly illuminated but I see no message on the LCD.

Dial not in AUTO RUN position.

Turn dial to AUTO RUN position. Push Reset button or power cycle the controller.

Page 18: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

ESP-ME3 Controller18

EN Safety Information

CWARNINGSpecial precautions must be taken when valve wires (also known as station or solenoid wires) are locat-ed adjacent to, or share a conduit with other wires, such as those used for landscape lighting, other “low voltage” systems or other “high voltage” power.

Separate and insulate all conduc-tors carefully, taking care not to damage wire insulation during installation. An electrical “short” (contact) between the valve wires and another power source can damage the controller and create a fire hazard.

All electrical connections and wiring runs must comply with local build-ing codes. Some local codes require that only a licensed or certified electrician can install power. Only professional personnel should in-stall the controller. Check your local building codes for guidance.

Outdoor controller shall be permanently connected to fixed wiring by a flexible cord, and have a cord anchorage. The cord anchorage shall relieve conductors from strain, including twisting, at the terminals and protect the insulation of the conductors from abrasion.

CCAUTIONStationary appliances not fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvolt-age category III, the instructions state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules

This appliance can be used by chil-dren aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

For controllers not provided with supply cord, the fixed installation must include a dis-connecting device for all three poles suitable for overvoltage category III protection.

NOTICEUse only Rain Bird approved accessory devices. Unapproved devices may damage the controller and void the warranty. For a list of compatible devices go to: www.rainbird.com

Changes or modifications not ex-pressly approved by Rain Bird could void the user’s authority to operate the equipment.Date and time are retained by a lithium battery which must be disposed of in accordance with local regulations.

Certifications

Supplier’s Declaration of Conformity 47 CFR § 2.1077 Compliance Information

Unique Identifier: ESP-ME3 (ESP4ME3)

Responsible Party – U.S. Contact Information

Rain Bird Corporation 9491 Ridgehaven Court San Diego, CA 92123 Ph. (858) 268-2650

FCC Compliance Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harm-ful interference, and (2) this device must accept any interference received, including interfer-ence that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B dig-ital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a res-idential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interfer-ence to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equip-ment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

• Changes or modifications not expressly approved by Rain Bird could void the user’s authority to operate the equipment.

ICES-003 Compliance Label/Étiquette de conformité à la NMB-003

CAN ICES-3(B)/NMB-3(B)

Page 19: ESP-ME3 Controller - Rain Bird · Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3

The Intelligent Use of Water®LEADERSHIP · EDUCATION · PARTNERSHIPS · PRODUCTS

At Rain Bird, we believe it is our responsibility to develop products and technologies that use water efficiently. Our commitment also extends to education, training and services for our industry and community.

The need to conserve water has never been greater. We want to do even more and with your help we can. Visit www.rainbird.com for more information about The Intelligent Use of Water®.

Rain Bird Corporation6991 East Southpoint Road

Tucson, AZ 85756USA

Tel: (520) 741-6100

Rain Bird TurkeyÇamlık Mh. Dinç Sokak Sk. No.4 D:59-60

34760 Ümraniye, İstanbulTÜRKIYE

Tel: (90) 216 443 75 [email protected]

www.rainbird.com.tr

Rain Bird Ibérica S.A.C/ Valentín Beato, 22 2ª Izq. fdo

28037 MadridESPAÑA

Tel: (34) 91 632 48 [email protected] · www.rainbird.es

[email protected]

Rain Bird Corporation970 W. Sierra Madre Ave.

Azusa, CA 91702USA

Tel: (626) 812-3400

Rain Bird Europe SNC Rain Bird France SNC

240 rue René DescartesBâtiment A, parc Le Clamar

BP 4007213792 AIX-EN-PROVENCE CEDEX 3

FRANCETel: (33) 4 42 24 44 61

[email protected] · [email protected] · www.rainbird.fr

Rain Bird Australia Pty Ltd.Unit 13, Level1

85 Mt Derrimut RoadPO Box 183

Deer Park, VIC 3023Tel: 1800 724 624

[email protected]/au

Technical Services for U.S. and Canada only:

1 (800) RAINBIRD1-800-247-3782

www.rainbird.com

Rain Bird International1000 W. Sierra Madre Ave.

Azusa, CA 91702USA

Tel: +1 (626) 963-9311

Rain Bird Deutschland GmbHKönigstraße 10c70173 StuttgartDEUTSCHLAND

Tel: +49 (0) 711 222 54 [email protected]

Rain Bird Brasil Ltda.Rua Marques Póvoa, 215Bairro Osvaldo RezendeUberlândia, MG, Brasil

CEP 38.400-438Tel: 55 (34) 3221-8210www.rainbird.com.br

) Registered trademark of Rain Bird Corporation( 2020 Rain Bird Corporation D41274 15JA20