ENVOLUTION VANTAJ ACM PANEL DRY JOINT SYSTEM WET JOINT SYSTEM · 2014-07-09 · DRY JOINT SYSTEM...

1
DRY JOINT SYSTEM WET JOINT SYSTEM ENVOLUTION VANTAJ ACM PANEL Vantaj™ ACM, by DAMS, Inc., offers both wet and dry joint route and return systems. The Dry Joint System is a high-performance composite panel cladding designed to control the impact of wind-driven rain on exterior walls. The system utilizes a perimeter attachment system that functions as a pressure-equalized rainscreen. This limits direct entry of wind-driven rain, prevents capillary action and manages cavity drainage to impede entry of water into the building. The Wet Joint System utilizes continuous perimeter extrusions that reinforce the panel’s return and features sliding angle clips and exposed caulking. ©2014 Metl-Span – A Division of NCI Group, Inc. All rights reserved. Printed in the U.S.A. Dry Joint Systems Pressure equalized rainscreen design principle ACM joint filler allowing for variable joint dimensions and color System designed to accommodated thermal expansion Sealant free reveals Fully tested for air, water and structural performance Independently tested to AAMA 508 voluntary test method for pressure equalized rainscreen wall cladding systems Wet Joint Systems Utilizing a backer rod with silicone sealant systems joints. (½" caulked joint typical) Weather tight Low maintenance and cost effective Tested for ASTM 283, ASTM 330, ASTM 331 and AAMA 501 VANTAJ™ ACM PANEL FEATURES ENVOLUTION.COM 877.585.9969 (toll free) 972.221.6656 (main) 972.420.9382 (fax) 1720 LAKEPOINTE DRIVE, SUITE 101 LEWISVILLE, TX 75057 Aluminum & Metal Composite Material: Aluminum, brushed aluminum, anodized aluminum, zinc, stainless steel, and copper Surface Treatment: Coil-coated solid, mica, metallic, anodized, faux wood, faux stone, color changing, natural & decorative metals Composition: Continuously bonding two thin sheets of aluminum or metal on either side of an extruded thermoplastic (PE) or mineral-fire retardent thermoplastic (FR) core Typical ACM skin thickness: 0.020" (0.51 mm) ACM / MCM skins can vary based on natural materials. Sustainability: The raw materials & finishing systems used in the ACM panel products / systems have been selected to maximize the use of recycled content. Certification categories points available. ACM / MCM MATERIALS Fire Performance: Tested by independent testing laboratories to the applicable standards / requirements of the International Building Code for combustible construction. Standard Panel Sizes: Thickness: 0.157" (4 mm), 0.236" (6 mm) Widths: 50" (1270mm), 62" (1575mm) Lengths 196" (4978mm) - Custom lengths available Standard Tolerances: Width: +/-0.08" (2.03 mm) Length: +/-0.16" (4.06 mm) Panel Bow: Maximum 0.8 percent of any 72" (1829 mm) panel dimension Squareness: Maximum 0.20" (5.08 mm) For additional information and clarification, contact your Metl-Span consultant.

Transcript of ENVOLUTION VANTAJ ACM PANEL DRY JOINT SYSTEM WET JOINT SYSTEM · 2014-07-09 · DRY JOINT SYSTEM...

Page 1: ENVOLUTION VANTAJ ACM PANEL DRY JOINT SYSTEM WET JOINT SYSTEM · 2014-07-09 · DRY JOINT SYSTEM WET JOINT SYSTEM ENVOLUTION ™ VANTAJ™ ACM PANEL Vantaj™ ACM, by DAMS, Inc.,

DRY JOINT SYSTEM

WET JOINT SYSTEM

E NVO LUT I O N ™ VANTAJ ™ ACM PAN E LVantaj™ ACM, by DAMS, Inc., offers both wet and dry joint route and return systems. The Dry Joint System is a high-performance composite panel cladding designed to control the impact of wind-driven rain on exterior walls. The system utilizes a perimeter attachment system that functions as a pressure-equalized rainscreen. This limits direct entry of wind-driven rain, prevents capillary action and manages cavity drainage to impede entry of water into the building. The Wet Joint System utilizes continuous perimeter extrusions that reinforce the panel’s return and features sliding angle clips and exposed caulking.

©2014 Metl-Span – A Division of NCI Group, Inc. All rights reserved. Printed in the U.S.A.

Dry Joint Systems• Pressure equalized rainscreen design principle• ACM joint fi ller allowing for variable joint dimensions and color• System designed to accommodated thermal expansion • Sealant free reveals• Fully tested for air, water and structural performance• Independently tested to AAMA 508 voluntary test method for pressure equalized rainscreen wall cladding systems

Wet Joint Systems• Utilizing a backer rod with silicone sealant systems joints. (½" caulked joint typical)• Weather tight• Low maintenance and cost effective• Tested for ASTM 283, ASTM 330, ASTM 331 and AAMA 501

VANTAJ™ ACM PANEL FEATURES

ENVOLUTION.COM

877.585.9969 (toll free)972.221.6656 (main)972.420.9382 (fax)

1720 LAKEPOINTE DRIVE, SUITE 101LEWISVILLE, TX 75057

Aluminum & Metal Composite Material: • Aluminum, brushed aluminum, anodized aluminum, zinc, stainless steel, and copperSurface Treatment: • Coil-coated solid, mica, metallic, anodized, faux wood, faux stone, color changing, natural & decorative metals Composition: • Continuously bonding two thin sheets of aluminum or metal on either side of an extruded thermoplastic (PE) or mineral-fi re retardent thermoplastic (FR) core• Typical ACM skin thickness: 0.020" (0.51 mm)• ACM / MCM skins can vary based on natural materials.Sustainability: • The raw materials & fi nishing systems used in the ACM panel products / systems have been selected to maximize the use of recycled content. Certifi cation categories points available.

ACM / MCM MATERIALS

Fire Performance: • Tested by independent testing laboratories to the applicable standards / requirements of the International Building Code for combustible construction.Standard Panel Sizes: • Thickness: 0.157" (4 mm), 0.236" (6 mm)• Widths: 50" (1270mm), 62" (1575mm) • Lengths 196" (4978mm) - Custom lengths availableStandard Tolerances: • Width: +/-0.08" (2.03 mm)• Length: +/-0.16" (4.06 mm)• Panel Bow: Maximum 0.8 percent of any 72" (1829 mm) panel dimension• Squareness: Maximum 0.20" (5.08 mm)

• For additional information and clarification, contact your Metl-Span consultant.