Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016...
Transcript of Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016...
![Page 1: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/1.jpg)
01/03/2016
1
Envelope Optimization
Approach to Sustainability
NBC Chapter 11: section 8
Mili Majumdar
Ms Mili Majumdar (Convener)
Shri Karan Grover
Shri Rajan Venkateswaran
Rajan Rawal
Nimish Patel
Editorial help by Dr Jyotirmay Mathur and Varun Pothbare
Team
![Page 2: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/2.jpg)
01/03/2016
2
Apply bio climatic architectural principles and use onsite sources and sinks
Use of efficient envelope materials
Relax design criteria to reduce demand
Use efficient lighting ,equipment, space conditioning, water heating systems and effective controls.
Use renewable forms of energy to meet a part of consumption.
Optimize energy performance
…..Integrated design process
Integrated Approach
Wall optimization
Daylight optimization
HVAC
Building Energy Performance
Bioclimatic design
Artificial lighting
Roof optimization
Fenestration optimization
Daylight integration
Low energy strategies
![Page 3: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/3.jpg)
01/03/2016
3
Window to Wall Ratio Wall Assembly Options Insulation Options – Glass wool
Envelope
Insulation options - XPS Insulation Options – Insulated Roof Glazing Options
Building Envelope
•Walls / Opaque surfaces
•Roof
•Windows / Fenestration / Aperture
![Page 4: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/4.jpg)
01/03/2016
4
Insulation
High thermal mass
Air Cavity
High SRI coating
Walls Thermal performance of wall
Wall with insulation Rigid or semi rigid blocks
and boards,
Boards with impact or weather resistant surfaces suitable as exterior grade material,
Loose fill,
Foam and dry spray, and
Blankets, felts or sheets.
Wall with high thermal mass
Wall with Air Cavity
Walls
![Page 5: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/5.jpg)
01/03/2016
5
Wall with Air Cavity
Walls
Wall with high SRI coating
Reflection of incident heat
Walls
![Page 6: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/6.jpg)
01/03/2016
6
Roof with overdeck insulation
Cool Roofs
Green Roof
Roof
Tair inside
Troof surface
Tsky
Tair outside
Tceiling
a roof section, say...
first principles can be
fairly simple and are
universal
e.g. solar heating
processes which happen
everywhere
sun on roof surface leads to
temperature rise and
temperature rise to heat
transfer which occurs on
both sides affecting the
outdoor environment as well
as room temperature below
and everything gets
involved…
Building envelope: roof
![Page 7: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/7.jpg)
01/03/2016
7
Roof insulation through:
Use of preformed insulation materials
1) Expanded polystyrene sheet.
2) Extruded polystyrene sheet.
3) Polyurethane/polyisocyanurate sheet.
4) Perlite board.
In-situ application using spray applied polyurethane
Conventional roof insulation practices
Other traditional practices of roof insulation
Roofs
Insulation Options – Insulated Roof
![Page 8: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/8.jpg)
01/03/2016
8
Impact of insulation
Roof Wall Glazing_View Window AC Spaces
Alternative U-Value U-Value U-Value SHGC VLT Reduction in TR Load
W/m2K W/m2K W/m2K (%)
1 Base Case 2.49 3.17 6.17 0.815 0.88
2 ECBC Roof Case_Over deck 0.36 3.17 6.17 0.815 0.88 1.76
3 ECBC Roof Case_Under deck 0.37 3.17 6.17 0.815 0.88 -0.18
4 Glazing optimised Case 2.49 3.17 1.59 0.28 0.4 4.20
5 Cumilative 1(Over Deck) 0.36 3.17 1.59 0.28 0.4 9.67
6 Cumilative2 (Under Deck) 0.37 3.17 1.59 0.28 0.4 7.93
Building envelope optimization for Air conditioned and Non Air conditioned spaces
![Page 9: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/9.jpg)
01/03/2016
9
Building envelope: roof
Roof receives significant solar radiation
Roof insulation particularly important for hot climates $ inverted earthen pots
$ insulating material e.g vermiculite insulation
$ reflective surfaces e.g broken china mosaic , reflective paints for inclined roofs
Cool Roofs (minimum solar reflectance of 0.7and thermal emittance of 0.75)
Roof coatings
Broken china mosaic terracing
Cool colours
Traditional methods (lime wash)
Roof
![Page 10: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/10.jpg)
01/03/2016
10
Green Roof (evapo transpiration and thermal mass)
Roof
Wall Requirements Table 4.3.2 Opaque Wall Assembly U-factor and Insulation R-value Requirements
Maximum U-factor of the overall
assembly (W/m2-°C)
Minimum R-value of insulation alone (m2-°C/W)
Maximum U-factor of the overall assembly
(W/m2-°C)
Minimum R-value of insulation
alone (m2-°C/W)
Composite U-0.440 R-2.10 U-0.440 R-2.10
Hot and Dry U-0.440 R-2.10 U-0.440 R-2.10
Warm and Humid U-0.440 R-2.10 U-0.440 R-2.10
Moderate U-0.431 R-1.80 U-0.397 R-2.00
Cold U-0.369 R-2.20 U-0.352 R-2.35
Roof Requirement Table 4.3.1 Roof assembly U-factor and Insulation R-value Requirements
Maximum U-factor of the overall
assembly (W/m2-°C)
Minimum R-value of insulation alone (m2-°C/W)
Maximum U-factor of the overall assembly
(W/m2-°C)
Minimum R-value of insulation
alone (m2-°C/W)
Composite U-0.261 R-3.5 U-0.409 R-2.1
Hot and Dry U-0.261 R-3.5 U-0.409 R-2.1
Warm and Humid U-0.261 R-3.5 U-0.409 R-2.1
Moderate U-0.409 R-2.1 U-0.409 R-2.1
Cold U-0.261 R-3.5 U-0.409 R-2.1
![Page 11: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/11.jpg)
01/03/2016
11
Windows are most vulnerable to heat gains and losses.
Heat gain through glazed surfaces determined by the direct gain component (defined by shading coefficient) and U- value
Window size and location should be determined by: Orientation Daylight requirement Glazing type external shading wind direction Thermal comfort
Fenestration and shading devices
SHGC
reflected energy
re-emitted energy
re-emitted energy
directly transmitted energy
Solar Heat Gain Coefficient (SHGC) : SHGC refers to the ratio of the solar heat that passes through the glazing
to the total incident solar radiation. The lower the SHGC, the lesser the direct incident heat gains from the
glazing surfaces.
![Page 12: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/12.jpg)
01/03/2016
12
TOTAL HEAT GAIN
Heat Gain due to
direct solar radiation
Amount of heat
Transferred due to
temperature difference
Why SHGC is important ?
SHGC U - Value
Solar incident energy = 800 W
Temperature differential = 20º C
SHGC
of glass is = 0.3
U Value
of glass = 3.0
240 Watts 60 Watts
Total Heat Gain
=
300 Watts
80%
Source: ST.Gobain
![Page 13: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/13.jpg)
01/03/2016
13
![Page 14: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/14.jpg)
01/03/2016
14
![Page 15: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/15.jpg)
01/03/2016
15
http://213.211.198.27/wwshop/images/ManMarinCap.jpg
http://u1.ipernity.com/u/2/3F/3A/604735.fef07a581.l.jpg http://farm4.static.flickr.com/3102/2649874827_6fc6f36fe4.jpg?v=0
Vertical Screening through Jalis
![Page 16: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/16.jpg)
01/03/2016
16
Window sizes and heights
Separate apertures for view and daylight
WWR
Glass Specifications
Frames
Shading Devices
Fenestrations (AC and non AC spaces)
Window sizes and heights
Height of window head
Sill height (height from floor to the bottom of the window)
Use of separate apertures for view and daylight
Window wall ratio (WWR)
Fenestrations
![Page 17: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/17.jpg)
01/03/2016
17
Glass Specifications Visible transmittance (affecting daylight),
Visible reflectance (affecting heat and light reflection),
Thermal transmittance or U value (affecting conduction heat gains),
Solar heat gain (affecting direct solar gain),
Spectrum selectivity (affecting daylight and heat gain),
Glazing material, and
Glazing colour (affecting the thermal and visual properties of glazing systems).
Fenestrations
Shading Devices
External shading and screens/jalis,
Internal shading, and
Use of solar control glass.
Fenestrations
![Page 18: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/18.jpg)
01/03/2016
18
Window-Wall-Ratio (WWR) : The Window Wall Ratio refers to the ratio of the total fenestration area to the gross wall area.
ECBC in a prescriptive approach recommends a maximum WWR of 60%.
The portion of the glazing which lets in light is same in both cases.
This is why WWR is important. The rest of the glass does not contribute to daylight, only permits more heat inside.
Window Wall Ratio
![Page 19: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/19.jpg)
01/03/2016
19
Optimize glazing design
Recommended to maintain a maximum of 40% WWR
ECBC allows up to 60% in prescriptive approach and
40% in whole building approach
Use a combination of
external shading and
high performance glass
for
proper solar control
Day lighting and
glare control Study done by Skidmore, Owning and Meryll on impact of glass area on energy consumption
Glazing Requirements (for sun control and day lighting)
Vertical Fenestration U-factor and SHGC Requirements (U-factor in W/m2-ºC)
WWR = 40%
40% <WWR<=60%
Climate
Maximum U-factor
Maximum SHGC
Maximum SHGC
Composite
3.30
0.25 0.20
Hot and Dry
3.30
0.25
0.20
Warm and humid
3.30
0.25
0.20
Moderate
6.90
0.40
0.30
Cold
3.30
0.51
0.51
Minimum VLT Requirements
Window Wall Ratio
Minimum VLT
0-0.3
0.27
0.31-0.4
0.20
0.41-0.5
0.16
0.51-0.6
0.13
0.61-0.7
0.11
Mandatory controls for daylit areas
![Page 20: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/20.jpg)
01/03/2016
20
U-value thresholds specified in the ECBC
Climate Maximum U-factor (W/sq.m.-
oC)
Composite 3.3
Hot and Dry 3.3
Warm and Humid 3.3
Moderate 6.9
Cold 3.3
Climate Maximum U-factor (W/sq.m.-
oC)
Composite 0.44
Hot and Dry 0.44
Warm and Humid 0.44
Moderate 0.44
Cold 0.369
GLASS WALLS
Building Envelope impact on Energy Performance
![Page 21: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/21.jpg)
01/03/2016
21
Energy Efficient Envelope-Wall
9 inch Brick Wall
+ 1 inch
cement plaster on both sides
U Value- 0.32 btu/f2/hr/degF
9 inch Brick Wall
+ 1 inch plaster on both sides
+ 3 inch
Insulation
U Value- 0.07 btu/f2/hr/degF
Conventional case Energy Efficient Case
WALL
Energy Efficient Envelope-Roof
U Value- 0.40 btu/ft2/hr/degF
U Value- 0.07 btu/ft2/hr/degF
Conventional case
Energy Efficient Case
Roof
1 inch brick tile +
1 inch plaster +
4 inch brick coba +
8 inch RCC
1 inch brick tile +
3 inch insulation +
1 inch plaster +
4 inch brick coba +
8 inch RCC
![Page 22: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/22.jpg)
01/03/2016
22
Energy Efficient Envelope-Glass
U Value- 1.087 btu/ft2/hr/degF
SHGC – 0.815 U Value- 0.58 btu/ft2/hr/degF
SHGC – 0.25 for WWR <40%
Conventional case Energy Efficient Case
GLASS
Impact of Efficient Envelope
Base Case 233
30 % Efficient Envelope 163
Impact on Cooling load (TR)
Base Case 202
17 % Efficient Envelope 168
Impact on EPI (kWh/m2/yr)
![Page 23: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/23.jpg)
01/03/2016
23
Examples of optimized design
HAREDA, Panchkula
![Page 24: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/24.jpg)
01/03/2016
24
HAREDA, Panchkula
HAREDA, Panchkula
![Page 25: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/25.jpg)
01/03/2016
25
CESE building, IIT Kanpur
Suzlon OneEarth, Pune
![Page 26: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/26.jpg)
01/03/2016
26
INFOSYS, Hyderabad
INFOSYS, Hyderabad
![Page 27: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/27.jpg)
01/03/2016
27
Building Integrated Photo Voltaics
Integrated Renewable Energy Technologies
Scope of ECBC
Building Envelope
Interior and Exterior Lighting
Mechanical Systems
Service Water Heating
Electrical Power and Motors
![Page 28: Envelope Optimization · Editorial help by Dr Jyotirmay Mathur and Varun Pothbare Team . 01/03/2016 2 Apply bio climatic architectural principles and use onsite sources and sinks](https://reader033.fdocuments.net/reader033/viewer/2022050215/5f60fc38bb066954061378d3/html5/thumbnails/28.jpg)
01/03/2016
28
Compliance Approaches
Mandatory provisions to be complied
Prescriptive method
Whole Building Performance Method
(use of simulation tool )
Trade-off option
(applicable to Envelope only)
Comments