Enhance your surgical practice with Ellman® Radiosurgery · aesthetic, multi-specialty surgical,...
Transcript of Enhance your surgical practice with Ellman® Radiosurgery · aesthetic, multi-specialty surgical,...
Enhance your surgical practice with Ellman® Radiosurgery
3
About Ellman®Since Ellman® International was founded in 1959, the company has grown to become a global leader in advanced radiofrequency (RF) Technology for precision surgical and aesthetic procedures. In 2014 Ellman® was acquired by Cynosure®, Inc. the world‘s leading aesthetic laser company. In 2017 Cynosure® was acquired by Hologic, Inc. and now represents the aesthetic division. Today, Ellman® remains a strong surgical RF brand within Cynosure® and serves the aesthetic, multi-specialty surgical, dental and veterinary markets.
The Ellman® brand‘s reputation is known for providing high quality, reliable products including the legacy Surgitron® line of RF surgical Generators and the newer Pellevé® Wrinkle Reduction and Body Treatment System.
With a foundation based on excellence in Advanced Laser and RF Technologies, a strong research and development program and established worldwide sales channels, the commitment of Cynosure® to sustained growth will result in long term success.
Table of Content Page
Distinct benefits for your practice The Features• Exceptional precision and control through two distinct frequencies - Monopolar (4.0 MHz) and Bipolar (1.7 MHz)• 73% less thermal spread as compared to Bovie® 1250 and Valleylab® ForceFX™ in porcine tissue3
• Easy operation with clear setting display via Digital Control Panel• Reliable, consistent energy emission through Solid State Circuitry
The Benefits• Precision - sculpt precise incisions and excisions in very thin, delicate mobile or tension-free tissues
(e.g. eyelid skin, earlobe, labia, etc.)2
• Less burning or charring of tissues1
• Enhanced readability of histologic specimens8
• Excellent cosmetic results with minimal scar tissue4,5
• Quick recovery6
• Decreased post-operative pain7
The Return• With versatility across all specialties, Surgitron® Technology is a proven workhorse that will deliver years of
reliable, cost-effective performance in both hospital and office environments
Clinical Citations
1. High frequency RF surgery minimizes burning of tissue, unlike laser or conventional electrosurgery. Olivar, AC, et al, Ann. Clin. Lab Sci. (1999); 29 (4): p281-5.
2. Niamtu, J. Chapter 4B, “Radiowave Surgery in Oral and Maxillofacial Surgery”, in Distraction Osteogenesis of the Facial Skeleton, 2007, p30-37.
3. Data on file.4. Botero, G.E.S, J Otol Head Neck Surgery (1996); vol 24 (1), p69.
5. Aferzon, M, Derm Surgery (2002); vol 28, p735-738. 6. With less tissue destruction, healing is accelerated and patients can recover quickly.
Bridenstine, J.B., Derm Surgery (1998); vol 24, p397-400.7. High frequency RF surgery causes less trauma7. Ericsson, E, et al, The Laryngoscope
(2007); vol 117, p654.8. Minimal Heat Dissipation. Silverman, EB, et al, Veterinary Surgery (2007); vol 36, p50-56.
RF GENERATORS
Aesthetics & Surgical Capabilities 5Surgical Capabilities 6-7
RF RADIOSURGERY ACCESSORIES
Neutral Plates 8-9Cables 10-11Footswitches 12Converter & Adapter 13Handpieces 14-15 Bipolar Forceps 16-17Bayonet Bipolar Forceps 18-19ACe-Tip™ Non-Stick Forceps 20-21 RF ELECTRODES
Sterile/Single-Use Electrodes 23Empire® Microincision™ Needles 24-25 RF REUSABLE ELECTRODES
Standard Electrodes 26-31Insulated Electrodes 31ACe-Tip™ Advanced Composition Alloy 32Specialty Electrodes 32Reusable Electrode Sets 33
ACCESSORIES
Surgical Cart 34Miscellaneous 35
MULTI-SPECIALTY ACCESSORIES
Family Practice/Podiatry 36-37 Otorhinolaryngology 37-40Gynecology 41-42Ophthalmology/Oculoplastics 43Plastic Surgery 44Pellevé® Wrinkle Reduction System 45-47PelleFirm® RF Body Treatment 46Miscellaneous 47
I
II
III
IV
V
VI
I
| RF
GEN
ERAT
ORS
| Ae
sthe
tics
& S
urgi
cal C
apab
ilitie
s
PelleFirm® Handpieces with massage head
GlideSafe® Wrinkle Treatment Handpieces
RF Wrinkle Reduction
• GlideSafe® Wrinkle Treatment Handpieces for Skin Tightening*
• PelleFirm® Body Treatment Handpieces for temporary Reduction in Apperance of Cellulite.
• Hundreds of surgical Electrodes and Accessories available
• Ideal for Office and Clinic Environments
IEC5P-ST/220Shipped complete with:
40-0417 EU Power cord40-0419 UK Power cordDF-FSC# Dual Footswitch & CableIEC-HP1 IEC Foot-Controlled HandpieceIEC-3FHPB IEC 3-Button Fingerswitch HandpieceIEC-1FHPA 1-Button FSHP, Locking Chuck, Reusable, 1 pcIEC-NPD IEC Neutral PlateDSEP40 40 Medical Electrodes Assortment Package Sterile/Single-UseH66 Electrode ProtectorStandH79 Handpiece Clip“J” Series Bipolar Forceps (Item number determined by selection) see page 16-19
NOTE: Included accessories may vary by country and/or by special packages.
Pellevé® S5 Generator 220 - 240 V
4 5
Distinct waveforms for optimum clinical outcomesCut• Micro-smooth cutting • Negligible lateral heat • Ideal for skin incision and biopsy • Best cosmetic results 1,2
Blend• Cutting with hemostasis • Ideal for subcutaneous tissue dissection and planing
Especially useful in vascular areas while producing minimal amounts of lateral heat and tissue damage
Coag• Coagulation • Ideal for hemostasis with controlled penetration
Fulguration• Ideal for intentional tissue destruction
Bipolar• Pinpoint, micro-coagulation • Ideal for coagulation in and around critical anatomy
Powered by advanced RF Technology, the Pellevé® S5 energy source has advanced cooling and electronics inside that deliver the performance needed to power the GlideSafe® wrinkle Treatment Handpieces and PelleFirm® Body Treatment Handpieces. Since it evolved from the Surgitron® Dual 120, it also has full surgical capabilities, providing unparalleled surgical precision in soft tissue cutting and coagulation. The high frequency of 4.0 MHz minimizes thermal tissue damage along the incision path. The S5 offers complete versatility, with more options for use in surgical and aesthetic procedures than other energy-based platforms. The Pellevé® S5 redefines your surgical results with two distinct frequencies - 4.0 MHz (Monopolar) and 1.7 MHz (Bipolar) - for outstanding precision and control. The Pellevé® S5 is the only Ellman® energy source compatible with GlideSafe® and PelleFirm® Handpieces.
Pellevé® S5 The Pellevé® S5 System is a more advanced version of our proven Surgitron® Dual 120 RF Generator, providing maximum control in precision cutting and coagulation, plus more versatility than other energy-based technologies, including.
How does Radiosurgery work?
RF GENERATORS
A radiofrequency Electrode tip becomes energized by the high frequency energy but does not become hot. This energy provides specific and delicate tissue interaction, resulting in a focused cutting and coagulating effect, which disintegrates and volatilizes cells thereby minimizing the amount of lateral tissue destruction. Healing is rapid and pain is minimized with reduced tissue damage.
Clinical Citations1. With less tissue destruction, healing is accelerated and patients can recover quickly. Bridenstine, J.B., Derm Surgery (1998); vol 24, p397-400.2. High frequency RF surgery causes less trauma7. Ericsson, E, et al, The Laryngoscope (2007); vol 117, p654.
I I
| RF
GEN
ERAT
ORS
| Su
rgic
al C
apab
ilitie
s
| RF
GEN
ERAT
ORS
| Su
rgic
al C
apab
ilitie
s
6 7
Generates 120 Watts of Power4.0 MHz in Monopolar1.7 MHz in Bipolar Foot-Controlled Handpiece 3-Button Fingerswitch HandpieceBipolar Forceps Disposable Neutral Pad Electrode AssortmentSize: 22.86cm x 12.7cm x 33.02cmWeight: 8,2 kg
IEC3A-S30/220Shipped complete with:
40-0417 EU Power cord40-0419 UK Power cordDF-FSC# Dual Footswitch & CableIEC-HP1 IEC Foot-Controlled HandpieceIEC-3FHPB IEC 3-Button Fingerswitch HandpieceIEC-3FHPB/D Sterile/Single-Use 3-Button Fingerswitch HandpieceIEC-3FHPB/D1 Sterile 3-Button FSHP, Locking Chuck, 1 pcIEC-NPC IEC Neutral PlateDSEP40 40 Medical Electrodes Assortment Package Sterile/Single-UseH66 Electrode Protector StandH79 Handpiece Clip“J” Series Bipolar Forceps (Item number determined by selection) see page 16-19
NOTE: Included accessories may vary by country and/or by special packages.
Generates 90 Watts of Power4.0 MHz in Monopolar1.7 MHz in BipolarFoot-Controlled Handpiece 3-Button Fingerswitch HandpieceBipolar Forceps Disposable Neutral Pad Electrode AssortmentSize: 22.86cm x 12.7cm x 33.02cmWeight: 8,2 kg
IEC3A-S30-90/220Shipped complete with:
40-0417 EU Power cord40-0419 UK Power cordDF-FSC# Dual Footswitch & CableIEC-HP1 IEC Foot-Controlled HandpieceIEC-3FHPB IEC 3-Button Fingerswitch HandpieceIEC-3FHPB/D Sterile/Single-Use 3-Button Fingerswitch HandpieceIEC-NPC IEC Neutral PlateDSEP40 40 Medical Electrodes Assortment Package Sterile/Single-UseH66 Electrode Protector StandH79 Handpiece Clip“J” Series Bipolar Forceps (Item number determined by selection) see page 16-19
NOTE: Included accessories may vary by country and/or by special packages.
The Surgitron® Dual RF™ 90
The Surgitron®
Dual RF™ 120For those doctors wanting to perform advanced surgical procedures.
The Surgitron® Dual RF™ 120 Devices 4 Megahertz (MHz) Technologycreates very little heat when cutting/coagulating tissue, resulting in minimal lateralthermal damage to surrounding tissues. Like all of Ellman® Generators it operates in Cut, Blend, Coag and Fulgrate waveforms. It also includes Bipolar waveforms.
For those doctors wanting to perform advanced surgical procedures.
The Surgitron® Dual RF™ 90 Devices 4 Megahertz (MHz) Technologycreates very little heat when cutting/coagulating tissue, resulting in minimal lateralthermal damage to surrounding tissues. Like all of Ellman® Generators it operates in Cut, Blend, Coag and Fulgrate waveforms. It also includes Bipolar waveforms.
Surgitron® Dual RF™ 90 IEC 220 VSurgitron® Dual RF™ 120 IEC 220 V
|
RF
ACC
ESSO
RIES
|
Neu
tral
Pla
tes
|
RF
ACC
ESSO
RIES
|
Neu
tral
Pla
tes
II
II
8 9
IEC-NPDStandard Size, Single-UseFor Dual RF™, Pellevé® S5, AcuSect®(25 pcs)
IEC Disposable Neutral Plate
IEC-NPD-SSmall Size, Single-Use For Dual RF™, Pellevé® S5, AcuSect® and RadioLase® Devices(25 pcs)
IEC Disposable Neutral Plate
H4Reusable, CoatedFor the EMC Device(1 pc)
EMC Neutral Plate
IEC-NPD1Disposable (1/PKG)
IEC Neutral Pad
IEC-NPCReusable, CoatedFor Dual RF™, AcuSect® and RadioLase® Devices(1 pc)Note: For minor, low power procedures only
IEC Neutral Plate
RF RADIOSURGERY ACCESSORIES
Neutral Plates
By understanding our customer’s needs, we provide specialty products to accommodate every practice. Along with our family of RF Generators, we offer an extensive selection of Monopolar and Bipolar accessories, available in Reusable and single/sterile use. Our quality products provide consistent performance resulting in patient confidence.
The Ellman® Single-Use Neutral Plate is a sensing, pre-gelled, self-adhering, dispersive pad. The effective Electrodes are two aluminum oil conductors, covered by a hydrogel conductive adhesive. The conductive hydrogel provides a low-current density return path from the patient to the RF Device while the two foils provide a means of sensing contact quality.
not illustrated
II II
| RF
ACC
ESSO
RIES
| Ca
bles
| RF
ACC
ESSO
RIES
| Ca
bles
10 11
Quick-Connect™ CableFor use with Suction Tonsil and Suction Adenoid Probes, Disposable Suction Coagulators, Mono Stan RF Forceps and Rodin™ Micro Surgery Handpieces.
Snare CableFor use with Polyp Snare™
IEC-JX/BReusable, Bipolar For use with Surgitron® Dual RF™, Pellevé® S5, AcuSect® and RadioLase® Devices (1 pc)
IEC-SP020Reusable, MonopolarFor use with Surgitron® Dual RF™, Pellevé® S5, AcuSect® and RadioLase® Devices (1 pc)
IEC-H7BReusable, MonopolarFor use with Surgitron® Dual RF™, Pellevé® S5, AcuSect® and RadioLase® Devices (1 pc)
JXReusable, BipolarFor use with EMC Device (1 pc)
JX/EReusable, BipolarFor use with EMC Device (1 pc)
Bipolar CableEllman® offers both Reusable and single-use options for use with Bipolar Compatible Generators. See our family of Bipolar Forceps.
Cables
II II
| RF
ACC
ESSO
RIES
| Co
nver
ter &
Ada
pter
| RF
ACC
ESSO
RIES
| Fo
otsw
itche
s
12 13
DF-FSCFor Surgitron® Dual RF™, Pellevé® S5,AcuSect® and RadioLase® Devices(1 pc)
Dual Frequency Footswitch & Cable
EMCH95AFor use with EMC Device(1 pc)
Bipolar Converter
SVFSCFor use with Surg-e®-Vac™Smoke Evacuation System(1 pc)
Pneumatic Footswitch
EMCKAReusableFor use with EMC Device Handpiece not included(1 pc)
Universal Fingerswitch
FTSW-2PCFor AcuSect® and RadioLase® Devices(1 pc)
Footswitch 2 Pedal, Compact
FootswitchesFootswitch activation for Ellman® Family of RF Generators. For use with Surgitron® FFPF EMC Generator.
Converter & Adapter
II II
| RF
ACC
ESSO
RIES
| Ha
ndpi
eces
| RF
ACC
ESSO
RIES
| Ha
ndpi
eces
14 15
H15For Surgitron® EMC Device Accepts 1.59mm Shaft
Blade Handpiece with Locking Chuck
Ellman® Handpieces are ergonomicaly designed to fit comfortably in your hand therefore maximizing productivity by reducing operator fatigue and discomfort.
Handpieces
Reusable 3-Button Fingerswitch Handpiece with Locking Chuck
IEC-X3FHPBReusableAccepts 1.59mm and 2.38mm Shaft ElectrodesFor Surgitron® Dual RF™ and Pellevé® S5 Devices (2 pcs)
MicroInsulated Needle Handpiece with Locking Chuck
IEC-XH136For Surgitron® Dual RF™, Pellevé® S5, AcuSect®and RadioLase® 3 Devices (2 pcs)
XH136For Surgitron® EMC Device (2 pcs) Reusable (1 pc)Smaller orifice for insertion of Ellman®MicroInsulated Needles only (Cat. No. H137)Included in Cosmetic Treatment Package
IEC-3FHPB/DSterile/Single-UseAccepts 1.59mm and 2.38mm Shaft ElectrodesFor Surgitron® Dual RF™ and Pellevé® S5 Devices (10 pcs)
IEC-X1FHPAReusableAccepts 1.59mm and 2.38mm Shaft ElectrodesFor AcuSect® and RadioLase® Devices (2 pcs)
Foot-Controlled Handpiece with Locking ChuckIEC-XHP1For Surgitron® Dual RF™, Pellevé® S5, AcuSect®and RadioLase® Devices
XHP1For Surgitron® EMC DeviceReusable (2 pcs) Accepts 1.59mm and 2.38mm Shaft Electrodes
XKO1ReusableAccepts 1.59mm and 2.38mm Shaft Electrodes (2 pcs)
Rodin® Microsurgery HandpieceXRHPLength 9.89cm, Width 1.17cmReusable (2 pcs). Requires IEC Quick-Connect™ CableAccepts 1.59mm ShaftFor Surgitron® Dual RF™, Pellevé® S5 AcuSect® and RadioLase® Devices(For Quick-Connect™ Cable, Cat. No. IEC-SP020)
Single-Use 3-Button Fingerswitch Handpiece with Locking Chuck
1-Button Fingerswitch Handpiece with Locking Chuck
1-Button Fingerswitch Handpiece with Locking Chuck
IIII
| RF
ACC
ESSO
RIES
| Bi
pola
r For
ceps
| RF
ACC
ESSO
RIES
| Bi
pola
r For
ceps
Surgitron® Dual RF™Pellevé® S5, & RadioLase®
Bipolar Cables
10 mm
8 mm
8 mm
10 mm
5 mm
10 mm
10 mm
10 mm
10 mm
1716
J10 Length 16.2cmØ 2.0mm Straight Tip
J11 Length 12.2cm Ø 0.4mm Straight Tip
J12 Length 10.9cmØ 1.0mm Straight Tip
J19 Length 13.6cmØ 2.0mm Straight Tip
J1 Length 9.5cm Ø 0.4mmStraight Tip
J1B Length 9.5cmØ 0.4mmBent Tip
J2 Length 9.5cmØ 0.3mmCurved Flat/Angled Tip
J3 Length 7.8cmØ 0.4mmAngled Tip
J4 Length 7.8cmØ 0.3mmStraight Tip
Bipolar ForcepsEllman® offers a variety of Bipolar Forceps with specialty specific shapes and sizes, resulting in clean wet-field pinpoint coagulation.
II II
| RF
ACC
ESSO
RIES
| Ba
yone
t Bip
olar
For
ceps
| RF
ACC
ESSO
RIES
| Ba
yone
t Bip
olar
For
ceps
10 mm 10 mm
10 mm
18 19
J7 Length 17.3cmØ 1.0mm, Bayonet Flat Tip
J17 Length 17.9cmØ 1.0mm, BayonetSingle External Tip Insulated
J18 Length 16.9cmØ 0.5mm, Bayonet
J20 Length 16.6cmØ 2.0mm, Bayonet
J21 Length 19.7cmØ 1.0mm, Bayonet
J7U Length 17.3cmØ 1.0mm, Bayonet45° Up, Flat Tip
J7D Length 17.3cmØ 1.0mm, Bayonet45° Down, Flat Tip
J13 Length 15.6cmØ 1.0mm, Bayonetnon-stick epistaxis Serrated Tip
Enhanced access to the surgical environment for increased visibility.
Bayonet Bipolar Forceps
10 mm
10 mm
II II
| RF
ACC
ESSO
RIES
| AC
e-Ti
pTM N
on-S
tick
Forc
eps
| RF
ACC
ESSO
RIES
| AC
e-Ti
pTM N
on-S
tick
Forc
eps
10mm
10mm
10mm
10mm
8mm
10mm
10mm
10mm
20 21
ACBF-010Length 8.89cmØ 0.5mmStraight Tip
ACBF-014Length 15.9cmØ 0.5mm Straight Tip
ACBF-011Length 8.89cmØ 0.5mmBent Tip
ACBF-017Length 17.8cmØ 1.5mmStraight Tip
ACBF-012Length 11.43cmØ 0.5mmStraight Tip
ACBF-021Length 16.51cmØ 1.0mm BayonetSerrated Tip
ACBF-013Length 14.0cmØ 0.5mmStraight Tip
ACBF-022Length 18.41cmØ 1.0mmBayonet Tip
Featuring advanced composition alloy providing non-stick and low temperature technology. Resulting in minimal adherence of tissue, low absorption, and tissue preservation.
ACe-Tip™ Non-Stick Forceps
*Data on file.FDA Submission Packet 510 (k) K071343
III
|
RF
ELEC
TRO
DES
III
|
RF
ELEC
TRO
DES
|
Ste
rile/
Sing
le-U
se E
lect
rode
s
About Ellman® Electrodes
The insulated shaft of most Electrodes can be bent or contoured to enhance access. Note: Empire® MicroIncision™ Sterile Needles are not bendable.
INFORMATIONOrdering Electrodes:
Code To Electrode Prefixes:T- Package of 2 pieces X- Package of 5 pieces (Not all items available in 5-packs)
Code To Electrode Suffixes:B- BendableD- Disposable (Sterile/Single-Use)Most Electrodes come with 1.59mm shaft size and some are available with 2.38mm shaft sizes.Use “Q” as a prefix when ordering 2.38mm shaft size, i.e. QTA8BLonger Electrode shaft sizes may be available, usually 10.16mm.
Please contact us to inquire about available shaft diameters and Electrode lengths.
22 23
RF ELECTRODES Sterile/Single-Use ElectrodesAvailable for use with the Ellman® family of RF Generators, we provide an assortment of reusable and single-use Electrodes in various shapes and sizes.
Our Sterile/Single-Use RF Electrodes eliminate the risk of cross-contamination, as well as ensuring consistent performance and patient confidence. Available in 1.59mm shaft only (25 pcs per Box).
B1D Round Loop ElectrodeØ 6.35mm
B2D Round Loop ElectrodeØ 9.53mm
A2D Fine Wire Electrode Length 9,52mm
A3D/OS Needle Electrode Length 19.05mm
A8D Vari-Tip™ Wire Electrode Adjustable Cutting Wire
C3D Diamond Loop ElectrodeØ 4.76mm
D8D Ball ElectrodeØ 2.3mm
E3D Scalpel Electrode, BrassLength 25.4mm, 3.30mm Wide, 0.25mm Thick
E4D Scalpel Electrode, BrassLength 12.7mm, 3.30mm Wide, 0.25mm Thick
F1D Broad Needle Electrode
133D Niamtu Pin ElectrodeLength 3,18mm
DSEP40Sterile/Single-Use Assortment of 8 stylesRF Available in 1.59mm Shaft onlyIncludes 5 of each Electrode (40 pcs per pack)A2D, A8D, B1D, B2D, C3D, D8D, E3D, F1D
Medical Electrode Set
*Electrodes are not true to size
III |
RF E
LECT
ROD
ES |
Empi
re®
Mic
roIn
cisi
on™
Need
les
III
| RF
ELE
CTRO
DES
| Em
pire
® M
icro
Inci
sion
™ Ne
edle
s
2.5cm
5mm
1.9cm
5cm
10cm
3cm
Magnified view for all Empire® MicroIncisionTM
*Except TEE328 5mm
10mm
3cm
2524
TEE301 Length 3cm Straight
TEE302 Length 4cm Straight
TEE305 Length 3cm 45° Angle Shaft
TEE307 Length 3cm 45° Angle tip
TEE311 Length 17cm Straight
TEE316 Length 10cm 45° Angle Shaft
TEE325 Length 5cm Curved Shaft
TEE327 Length 1.9cm Straight
TEE328 Length 2.5cm 30° Curved Shaft Longer 5mm Tip
Empire® MicroIncision™ NeedlesDeliver focused High Frequency Radiowave energy. Empire® MicroIncision™ Needle Electrodes are used for precise cutting and coagulation during Radiosurgical procedures.
MicroIncision™ Needle ElectrodesSterile/Single-Use Available in 1.59mm Some available in 2.38mm (2 per pack)Use “Q” as a Prefix when ordering 2.38mm Shaft Size
IV
IV |
RF R
EUSA
BLE
ELE
CTRO
DES
| St
anda
rd E
lect
rode
s
| RF
REU
SAB
LE E
LECT
ROD
ES |
Stan
dard
Ele
ctro
des
Adjustable tip
26 27
RF REUSABLE ELECTRODESEllman® offers unique bendable Electrodes in different shapes and sizes such as the round loop, diamond loop, triangle loop and oval loop to assist all of your soft-tissue procedures. Commonly used for shaving lesions, contouring tissue, and biopsying specimens, these RF Electrodes help ensure consistent performance.
TA1B Length 9.53mm, Super Fine Wire
TA2B Length 9.53mm, Fine Wire
TA9B Length 9.53mm, Regular Wire
TA3B Length 9.53mm, Regular Needle
TF1BLength 12.7mm, Broad Needle
TF1B/4Length 10,2mm Broad Needle, Bent Tip
TA8B Vari-Tip™ Microdissection™ Needle, Fine Wire(comes with additional wire & has an adjustable depth)
T133B Pin ElectrodeLength 3.175mm
TA8B/4 Length 10,2mm, Vari-Tip™ Electrode
Standard Electrodes Needle Electrodes Reusable, 1.59mm or 2.38mm Shaft Size (2 pcs)Use “Q” as a Prefix when ordering 2.38mm Shaft Size
Needle Electrodes are commonly used for incisions and excisions in precise surgical procedures. Round Loop Electrodes are commonly used for shaving lesions, contouring tissue and obtaining biopsy specimens.
Diamond Loop ElectrodesReusable 1.59mm or 2.38mm Shaft Size (2 pcs)Use “Q” as a Prefix when ordering 2.38mm Shaft Size
Diamond Loop Electrodes are commonly used for one-stroke elliptical incisions.
Assorted Needle Electrode Set
Diamond Loop Electrodes Set
XA Includes one each of: TA1B, TA2B, TA3B, TA9B, TF1B (5 pcs)
TC1B 3,18mm Diamond Loop, Fine Wire
TC3B 4,76mm Diamond Loop, Fine Wire
TC6B 7,94mm Diamond Loop, Regular Wire
TC17B 6,35mm Diamond Loop, Fine Wire
TC18B 6,35mm Diamond Loop, Regular Wire
XCRB Regular WireIncludes one each of: TC18B, TC6B (2 pcs)
Choice of Wire Gauge
Super Fine - Used when minimal tissue alteration is desired. (0.004")
Fine - Used when less tissue alteration is desired (0.007")
Regualr - Used to produce more coagulation. (0.009")
*Electrodes are not true to size
IV
|
RF
REU
SAB
LE E
LECT
ROD
ES
| S
tand
ard
Elec
trod
es
|
RF
REU
SAB
LE E
LECT
ROD
ES
| S
tand
ard
Elec
trod
esIV
28 29
Triangle Loop Electrodes Reusable1.59mm or 2.38mm Shaft Size (2 pcs)Use “Q” as a Prefix when ordering 2.38mm Shaft Size
Triangle Loop Electrodesare commonly used forshaving lesions andcontouring tissue.
Round Loop Electrodes*Reusable1.59mm or 2.38mm Shaft Size (2 pcs)Use “Q” as a Prefix when ordering 2.38mm Shaft Size
Round Loop Electrodes are commonly used for shaving lesions, contouring tissue and obtaining biopsy specimens.
Assorted Triangle Loops Electrode Set
XTRB Regular WireIncludes one each of: TC8B, TC12B, TC14B(3 pcs)
TC9B 3.97mm Triangle Loop, Fine Wire
TC7B 6.35mm Triangle Loop, Fine Wire
TBBB 3.97mm Ø Round Loop, Fine Wire
TB10B 7.54mm Ø Round Loop, Regular Wire
TB10B/4 19/64’’ Ø Round Loop Elec. 4’’ L
TB4B 6.35mm Ø Round Loop, Regular Wire
TB4B/4 1/4’’ Ø Round Loop Elec. 4’’ L
TB5B 9.53mm Ø Round Loop, Regular Wire
TB1B 6.35mm Ø Round Loop, Fine Wire
TB1B/4 1/4’’ Ø Round Loop Elec. 4’’ L
TB2B 9.53mm Ø Round Loop, Fine Wire
TB9B 7.54mm Ø Round Loop, Fine Wire
TB3B 12.7mm Ø Round Loop, Fine Wire
TB6B 12.7mm Ø Round Loop, Regular Wire
TC8B 6.35mm Triangle Loop, Regular Wire
TC11B 7.54mm Triangle Loop, Fine Wire
TC12B 7.54mm Triangle Loop, Regular Wire
TC14B 9.53mm Triangle Loop, Regular Wire
Assorted Round Loop Electrode SetAssorted Round Loop Electrode Set
XBRB Regular WireIncludes one each of: TB6B, TB5B, TB10B, TB4B, TBBB (5 pcs)
XB (Formerly XBFB)Fine WireIncludes one each of: TB3B, TB2B, TB9B, TB1B, TBBB (5 pcs)
*Electrodes are not true to size
IV
| R
F RE
USA
BLE
ELE
CTRO
DES
|
Sta
ndar
d El
ectr
odes
IV
| RF
REU
SAB
LE E
LECT
ROD
ES |
Stan
dard
Ele
ctro
des
& In
sula
ted
Elec
trod
es
2mm
0.5mm
30 31
Ball ElectrodesReusable 1.59mm or 2.38mm Shaft Size (2 pcs) Use “Q” as a prefix when ordering 2.38mm Shaft Size
Ball Electrodes are commonly used for coagulation.
Oval Loop ElectrodesReusable1.59mm or 2,38mm Shaft Size (2 pcs)Use “Q” as a prefix when ordering2,38mm Shaft Size
Oval Loop Electrodes are commonly used for shaving lesions and contouring tissue.
TD3B 2mm Ball
TD8B 2.36mm Ball
TD9B 3.17mm Ball
TD10B 4.34mm Ball
TP4B 6,35mm Oval Loop, Regular Wire
Assorted Ball Electrode Set
XD Includes one each of: TD11B, TD10B, TD9B, TD8B, TD3B(5 pcs)
TD11B 4.75mm Ball
TP1B 3,97mm Oval Loop, Fine Wire
TP5B 7,54mm Oval Loop, Fine Wire
TP3B 6,35mm Oval Loop, Fine Wire
TP7B 9,53mm Oval Loop, Fine Wire
TP2B 3,97mm Oval Loop, Regular Wire
TP6B 7,54mm Oval Loop, Regular Wire
TP8B 9,53mm Oval Loop, Regular Wire
TP10B 12,7mm Oval Loop, Regular Wire
Insulated Needle ElectrodesReusable 1/2 mm Exposed TipInsulated Needle
Electrodes are used for the treatment of Telangiectasia and for epilation.
Insulated Electrodes
Scalpel ElectrodesReusable 1.59mm or 2.38mm Shaft Size (2 pcs)Use “Q” as a Prefix when ordering 2.38mm Shaft Size
Scalpel Electrodes are commonly used for incisions and excision of tissue. The blade shape provides broader coagulation than a needle Electrode.
TE1B 4,76mm Scalpel, 45° Angle
TE2B 9,53mm Scalpel
TE3B 25,4mm Scalpel
D6A Insulated Coated Needle0.004” Super Fine, White, (1 pc)
D6B Insulated Coated Needle0.007” Fine, Purple, (1 pc)
D6C Insulated Coated Needle0.009” Regular, Orange, (1 pc)
Empire® MicroTip Electrodes* Reusable 2mm Exposed Tip(2 pcs, one of each)
Empire® MicroTip Needles are tapered and have a pinpoint design which produces micro-smooth cutting and coagulation while creating less tissue alteration.
TEE227 Empire® MicroTip Needlesone .010” wire one .020” wireInsulated Coated (Clear Teflon)Needle Set; 2mm Exposed Tips
*Electrodes are not true to size
Insulated Needle Electrodes Set
D7 Includes one each of: D6A, D6B, D6C(3 pcs)
IVIV |
RF R
EUSA
BLE
ELE
CTRO
DES
| AC
e-TI
P™ A
dvan
ced
Com
posi
tion
Allo
y &
Spe
cial
ty E
lect
rode
s
| RF
REU
SAB
LE E
LECT
ROD
ES |
Reus
able
Ele
ctro
de S
ets
32 33
TNAEE287 1cm Needle, 76.2mm Curved Sleeve ACe-TipTM 1.59mm Shaft (2 pcs)
TNAB1B 6.35mm Round LoopACe-TipTM Fine Wire 1.59mm Shaft (2 pcs)
TNAB4B 6.35mm Round LoopACe-TipTM Regular Wire 1.59mm Shaft (2 pcs)
TNAA8B Vari-Tip™ACe-Tip™ 1.59mm Shaft (2 pcs)(comes with additional wire and has an adjustable depth)
TNAEE305 Empire® MicroIncision™Needle ACe-Tip™ 1.59mm Shaft (2 pcs)
TNAEE330 Chedly Punctal Occlusion (CPO) ElectrodeNeedle ACe-Tip™, 1.59mm Shaft (2 pcs)
Rhinophyma Electrode | Mucotome Electrodes* Set
Specialty Electrodes
EE234 ReusableRhinophyma Electrode SetSet of 3 pcs, one of eachEE233, EE232, EE231(5 pcs)
Standard Electrode SetsS10B Reusable1.5875mm or 2.38125mm shaft size Use “Q” As a prefix when ordering 2.38125mm Shaft SizeIncludes one of each Electrode: TC7B, TB1B, TC3B, TA3B, TD8B, TF1B, A8B(7 pcs)
Standard Electrode Sets
S10B/4 4” Includes one of each Electrode: TA8B/4”, TC3B/4”, TC7B/4”, TD8B/4”(4 pcs)
Standard Electrode Sets
S12B Includes 1 of each Electrode:TF1B, TA2B, TA3B, TC3B, TD8B, TBBT, TB1B, TA8B(8 pcs)
Standard Electrode Sets
S13B Includes 1 of each Electrode:TF1B, TA2B, TA3B, TC3B, TD8B, TB2B, TA8B, TD8B/4(8 pcs)
*Electrodes are not true to size
ACe-Tip™ Advanced Composition Alloy
Reusable Electrode Sets
The Ellman® ACe-Tip™ Electrodes are designed to reduce resistance impedance which causes less undesired lateral heat compared to tungsten steel Electrodes and 45% reduction in the zone of hyalinization has been demonstrated. ACe-Tip™ Electrodes glide smoothly through tissues and are excellent for sculpting and tissue shaping.
V
V
| A
CCES
SORI
ES
| S
urgi
cal C
arts
|
ACC
ESSO
RIES
|
Mis
cella
neou
s
Adjustable
34 35
With the surgical cart, your on the go storage set up is designed to provide a stress-free work environment with all your tools close and organized. Our carts are on wheels for easy mobility from room to room. They also feature shelves to hold accessories with a gooseneck arm for suction flexibility.
ACCESSORIES
H157 The elegantly designed H157 Cart includes 2 shelves for accessories, a gooseneck flexible arm and a convenient front handle for micro positioning.
Four rugged caster wheels ensure easy mobility from room to room. (Shown with Dual RF™ 120, Surg-e®-Vac™ and Accessories - Not included). Also compatible with Pellevé® S5 Generator.
NOTE: H157 Cart not compatible with AcuSect®, RadioLase or EMC Generators.
H157 Cart
H66 Electrode Protector Stand™For regular 2” Standard ElectrodesHolds 12 Electrodes ( 6 x 1.59mm and 6 x 2.38mm)(1 pc)
Electrodes not included
Electrode Protector Stand™
Surgical Cart
H1 Electrode BlockHolds 18 Electrodes (1.59mm)(1 pc)
Electrodes not included
Electrode Block
Protects your Electrodes from damage and breakage during the sterilization process.It will stand on any flat surface for easy identification and access to each Electrode.
Miscellaneous
| M
ULT
I-SPE
CIA
LTY
ACC
ESSO
RIES
| Fa
mily
Pra
ctic
e/Po
diat
ry
VI
| M
ULT
I-SPE
CIA
LTY
ACC
ESSO
RIES
| Fa
mily
Pra
ctic
e/Po
diat
ry |
Otor
hino
lary
ngol
ogy
VI
I 1cm I 1cm I
3736
Insulated Matrixectomy Electrode Set
H9ReusableSet of 3 Electrodes1.59 or 2.38mm ShaftMatrixectomy Electrode SetIncludes one each of: H10D & H10E
IEC-MJ21Reusable, Suggested for Blepharoplasty and Facelift Procedures 8.89cm LengthIncludes Quick-Connect™ Cable and Video CDFor use with Surgitron® Dual RF™ and Pellevé® S5 Devices
Micro Stan RF™ Forceps
IEC-MJ11/MReusable, Monopolar Forceps with Cutting, Coagulation, Irrigation and Suction Port Suggested for Facelifts 12.38cm LengthIncludes Quick-Connect™ Cable and Video CDFor use with Surgitron® Dual RF™and Pellevé® S5 Devices
Mini Mono Stan RF™ Forceps
Patented Dr. Constantin Stan Monopolar ForcepsThe Ellman® Micro, Mini and Mono Stan Forceps simultaneously dissect and coagulate tissues using the 4.0 MHz Radiofrequency. The inside of tips on the Mini Mono and Mono Stan Forceps are serrated.
*Electrodes are not true to size
IEC-MJ11Reusable, Monopolar Forceps with Cutting, Coagulation, Irrigation and Suction Port Suggested for Breast Augmentation Procedures 15.56cm LengthIncludes Quick-Connect™ Cable and Video CDFor use with Surgitron® Dual RF™ and Pellevé® S5 Devices
Mono Stan RF™ Forceps
MULTI-SPECIALTY ACCESSORIES
Family Practice/Podiatry
Otorhinolaryngology
The Ellman® Radiosurgical nail matrixectomy technique for Ingrown Toenail allows the matrix to be destroyed electrically with a teflon coated Electrode, which protects the overlying eponychium.
The Bayonet TurbinateElectrode and Bipolar Handpiece design includes a pencil grip for easy handling with a bayonet design for easy intranasal visualization during surgery.
H81A1Sterile/Single-UseRAUP Radiosurgically AssistedUvulopalatoplasty(2 pcs)
RAUP Electrode
TEE229ASterile/Single-Use For Volumetric Reduction of Redundant Tissue 1cm Insulated, 1 cm Exposed(2 pcs)
Sub-Mucosal VTR (UPP) Electrode
I ~2.4cm I ~1.9cm IIEC-I6D For Surgitron® Dual RF™, S5, AcuSect®and RadioLase® Devices
I6/JXE For EMC Device
IEC/I6D/L For Surgitron® Dual RF™, S5, AcuSect® and RadioLase® Devices
Bayonet RF Turbinate Volume Reduction Electrode™
not illustrated
VIVI
| M
ULT
I-SPE
CIA
LTY
ACC
ESSO
RIES
| Fa
mily
Pra
ctic
e/Po
diat
ry |
Otor
hino
lary
ngol
ogy
| M
ULT
I-SPE
CIA
LTY
ACC
ESSO
RIES
| Fa
mily
Pra
ctic
e/Po
diat
ry |
Otor
hino
lary
ngol
ogy
I 1cm I 1cm I 1cm I
38 39
TEE605Sterile/Single-Use For Volumetric Reduction of Redundant Tissue(2 pcs)
Tongue Base Reduction Electrode
TEE284(2 pcs)
HLTZ Tonsillotomy Electrode
The Micro-LarynxProbe allows quick and efficient coagulation and can be used for Granulomas, Papillomatosis, Cyst Biopsies, Vocal Cord Polyps, Posterior Cordectomy, Glottic and Sub-glottic Angiomas, Laryngeal Tumor and Laryngeal Biopsies.
IEC-EE275AReusableFor Surgitron® Dual RF™, Pellevé® S5, AcuSect® and RadioLase® Devices1.59mm Shaft, 240mm Long(3 pcs)
Micro-Larynx™ RF Probes
*Electrodes are not true to size
H45 Suction Tube 15.24cm Long, 2.38mm Orifice
H46 Suction Tube 15.24cm Long, 3.18mm Orifice
H47 Suction Tube 3-3/4" Long, 1/16" Orifice
H48 Suction Tube 3-3/4" Long, 2.38mm Orifice
Suction Coagulation Tubes For precise coagulation in wet-field environments where suction is required to aid in visualization
H43
Suction Coagulation End Connecter
VIVI
| M
ULT
I-SPE
CIA
LTY
ACC
ESSO
RIES
| Gy
neco
logy
| M
ULT
I-SPE
CIA
LTY
ACC
ESSO
RIES
| Fa
mily
Pra
ctic
e/Po
diat
ry |
Otor
hino
lary
ngol
ogy
40 41
Suction Adenoid Probes Set
ReusableSet of 3 Probes, Quick-Connect™ Cable and Cleaning Brush
Small 9mm with Quick-Connect™ CableMed 15mm with Quick-Connect™ CableLarge 19mm with Quick-Connect™ Cable
TEE263 3.17mm Ball, 10.16mm Long (2 pcs)
EE264 Set of 3Reusable, 1.59mm ShaftTEE261, TEE262, TEE263
INSULATED NECK
RF Assisted Tonsillotomy (Rat) Ball ElectrodesAn advancement over the traditional tonsillotomy. The RAT Electrodes permit controlled reduction of the tonsil without excessive thermal damage or blood loss.
W32 Reusable Bayonet, 25mm Loop (1 pc)
W32D Sterile/Single-Use (5 pcs)
W31 Reusable Bayonet, 20mm Loop (1 pc)
W31D Sterile/Single-Use (5 pcs)
W30 Reusable Bayonet, 25mm Loop (1 pc)
W30D Sterile/Single-Use (5 pcs)
W34 Reusable Bayonette, 5mm Ball (1 pc)
W34D Sterile/Single-Use (5 pcs)
W33D Sterile/Single-Use (5 pcs)
LLETZ Bayonet Electrodes
W35 LLETZ Bayonet Electrode Set Reusable (5 pcs)Use “D” as a suffix when ordering Sterile/Single-Use
LLETZ Bayonet Electrode Set
Gynecology
W18 Reusable90mm Length, 5mm Ball
not illustrated
External Genital Lesion RF Electrodes
VIVI
| M
ULT
I-SPE
CIA
LTY
ACC
ESSO
RIES
| Gy
neco
logy
| Op
htha
lmol
ogy/
Ocul
opla
stic
s
| M
ULT
I-SPE
CIA
LTY
ACC
ESSO
RIES
| Gy
neco
logy
1.5mm3mm
42 43
W1 15mm x 10mm Loop, Reusable (1 pc)W1D 15mm x 10mm Loop, Sterile/Single-Use (5 pcs)
W2 20mm x 10mm Loop, Reusable (1 pc)W2D 20mm x 10mm Loop, Sterile/Single-Use (5 pcs)
W3 25mm x 10mm Loop, Reusable (1 pc)W3D 25mm x 10mm Loop, Sterile/Single-Use (5 pcs)
F2 Endo-Cervical Box 8mm x 11mm Box, Reusable (1 pc)F2D Endo-Cervical Box 8mm x 11mm Box, Sterile/Single-Use (5 pcs)
W18 5mm Ball, Reusable (1 pc)W18D 5mm Ball, Sterile/Single-Use (5 pcs)
G1 Conization Electrode
G1/4 10.16cm Long, Rotated at 360° to provide a cone Shaped Specimen
Conization ElectrodeReusable
Standard Electrode Set
S10B/4 10.16cm Shaft Length (4pcs)
S10B/4 4” include one of each electrode of: A8B/4”, C3B/4”, C7B/4”, D8B/4”
The Ellman® LLetz Loop Electrodes are used for the diagnosis and treatment of cervical intraepithelial neoplasia (CIN) and dysplasia.
TA10/C1Reusable. 2" Electrodes1.5mm of active 10.16cm Wire (2 pcs)
TA10/C2Reusable. 2" Electrodes3.0mm of active 10.16cm Wire (2 pcs)
Ophthalmic Micro-Dissection Electrodes™
A10ReusableSet of two (TA10/C1 and TA10/C2 1.5mm and 3.0mm, 10.16cm Wire - one of each)
Ophthalmic Micro-Dissection Electrodes™ Set
TNAEE330Reusable set of two ACe-Tip™ Electrodes
Chedly Punctal Occlusion (CPO) ElectrodeThe Chedly Punctal Occlusion Electrode dilates the punctum and is then activated to coagulate the tissues to occlude the punctual opening.
4 m
m
Ophthalmology / Oculoplastics
The Ellman® LLetz Loop Electrodes Set
W4Includes 1 of each in 5 Styles, Reusable:W1, W2, W3, F2, W18(5 pcs)
Available in 1.59mm or 2.38mmUse “Q” as a prefix when ordering 2.38mm shaft sizeUse “D” as a suffix when ordering Sterile/Single-Use Versions of the LLETZ Loop Electrodes.
not illustrated
not illustrated
VIVI
| M
ULT
I-SPE
CIA
LTY
ACC
ESSO
RIES
| Pe
llevé
® W
rinkl
e Re
duct
ion
Syst
em
| M
ULT
I-SPE
CIA
LTY
ACC
ESSO
RIES
| Pl
astic
Sur
gery
44 45
Cosmetic Treatment PackageFor treating telangiectasia and epilation of hair follicles
H135A For EMC Device
IEC-H135A For S5, Surgitron® Dual RF™, AcuSect® and RadioLase® Devices
Package Includes: One MicroInsulated Needle Handpiece, 50 MicroInsulated Sterile Needles and 50 Patient Education Brochures
XH136 MicroInsulated Needle Handpiece™ for EMC Device (2 pcs)
IEC-XH136 MicroInsulated Needle Handpiece™ For S5, Surgitron® Dual RF™, AcuSect® and RadioLase® Devices (2 pcs)
H137 MicroInsulated Sterile Needles (50 pcs)
P2VPHPDVari-Pack 10mm, 15mm & 20mm
GlideSafe® Handpieces Vari-Pak
Cosmetic Treatment Package
MicroInsulated Needle Handpiece
50 MicroInsulated Sterile Needles
50 Patient Education Brochures
is an effective, comfortable way to remove small unsightly facial “spider veins” with minimal recovery time, minimal scarring and immediate improvement in appearance.
Plastic SurgeryThe Ellman® Cosmetic Treatment Package
DDERM40
Assorted Sterile/Single-Use Electrodes 1.59mm Shaft (4 Electrode Styles)
Dermatology Electrode Assortment Set
D8D (15 pcs)
B1D (5 pcs)
F1D (15 pcs)
A8D (5 pcs)
Magnified view of MicroInsulated Needle
MicroInsulated Sterile NeedlesH137 (50 pcs)
P275HPD Pellevé® GlideSafe® 7.5mm Handpiece & Cable
P275HPD1Pellevé® GlideSafe® 7.5mm Handpiece (1pc)
P210HPD1Pellevé® GlideSafe® 10mm Handpiece (1pc)
P215HPD1Pellevé® GlideSafe® 15mm Handpiece (1pc)
P220HPD1Pellevé® GlideSafe® 20mm Handpiece (1pc)
P210HPD Pellevé® GlideSafe® 10mm Handpiece & Cable
P215HPD Pellevé® GlideSafe® 15mm Handpiece & Cable
P220HPD Pellevé® GlideSafe® 20mm Handpiece & Cable
Easily maneuver over contours of the face to gently heat the skin to stimulate new collagen growth and reduce wrinkles.
Pellevé® Wrinkle Reduction SystemGlideSafe® Handpieces
not illustrated
not illustrated
VIVI
| M
ULT
I-SPE
CIA
LTY
ACC
ESSO
RIES
| M
isce
llane
ous
| M
ULT
I-SPE
CIA
LTY
ACC
ESSO
RIES
| Pe
llevé
® W
rinkl
e Re
duct
ion
Syst
em |
Pelle
Firm
® RF
Bod
y Tr
eatm
ent
46 47
P2CBD 2m, for use with GlideSafe® Handpieces (6 pcs)
Pellevé® Treatment
Pellevé® GlideSafe® Acc Pack
Pellevé® Body Package Accessory
Pellevé® Face Package Accessory
Pellevé® Surg Acc Pack
Pellevé® S5 (M2) Transport Black Case
03-08 Gel, 8 oz
PGACCPK
PM2BODY
PM2FACE
PM2SURG
PVS5CASE
P325PFHP Pellevé® RF Handpiece, 25mm (Box of 3)
P325PFHPU Pellevé® RF Handpiece
P330PFHP Pellevé® RF Handpiece, 30mm (Box of 3)
P330PFHPU Pellevé® RF Handpiece
P325PFHP1 Pellevé® (1) 25mm Handpiece
P325PFMH Pellevé® Massage Head, 25mm (Box of 1)
P330PFHP1 Pellevé® (1) 30mm Handpiece
P330PFMH Pellevé® Massage Head, 30mm (Box of 1)
P3PFVP-WMH 2 Handpiece & 2 Heads
Pellevé® Vari-Pak
not illustrated
not illustrated
not illustrated
not illustrated
not illustrated
not illustrated
PelleFirm® RF Body TreatmentDeeply heats tissue and reduces the appearance of cellulite. Pellevé® Quick-Connect Cable
Miscellaneous
30 mm
25 mm
European Offices:
Cynosure Germany Robert-Bosch-Strasse 11A | 63225 Langen | +49 6103 20 11 10
Cynosure SpainAvenida Quitapesares | 1728670 Villapark Villaviciosa de Odón (Madrid) | +34 917 888 700
Cynosure FranceBâtiment 6 | 132-134 Bd de Verdun | 92400 Courbevoie | +33 1 46 67 22 50
Cynosure UKThe Old Barn Offices Lower Mount Farm | Cookham SL6 9EE | +44 1628 522252