English balton product training

77
www.balton.pl

description

Balton is an innovative design and medical production company...

Transcript of English balton product training

Page 1: English balton product training

www.balton.pl

Page 2: English balton product training

Balton is an innovative design and medical production company

10.000m2 of production area

400 employees

production rooms of the cleanness class C

Produces medical equipment for cardiology, radiology,

anaesthesiology, surgery, dialysis, urology and gynecology.

Balton has received ISO 9001 certificate, CE mark, patents and many

awards.

All products are of I, II a, II b and III medical grade.

Has own research and development facility with microbiological,

chemical and mechanical laboratories.

Cooperates with many scientific centres and clinics in Poland

and Europe as well as with companies from France, US,

Germany, Russia and Japan.

COMPANY OVERVIEW

Page 3: English balton product training

COMPANY HISTORY

1980 – stainless steel guide wires for introducers 1982 – epidural catheters 1985 – needles for hemodialysis1987 – catheters for angiography 1988 – catheters for dialyses 1990 – embolectomy catheters 1993 – urologic catheters 1995 – catheters for vessel catheterization 1997 – concession for the production of medical equipment

– ISO 9001 Certificate – catheters with hydrophilic coating

1999 – EC Design-Examination Certificate2000 – catheter for peripheral angioplasty

– catheter for coronary angioplasty „FRYDERYK”2002 – peripheral „NEPTUN” and coronary„CHOPIN2” balloon expanding stents2003 – self-expanding peripheral stent „JAGUAR”2004 – stent for renal vessels „NEFRO”2005 – stent for trachea and esophagus „TOR”

– cobalt – chromium coronary stent „KOS”– paclitaxel eluting stent „LUC-CHOPIN2”

2006 – thermodilution catheters „BALKAT”2007 – PTCA guide wire „RIDER®”2009 – intra-aortic balloon catheter set2010 – catheter for coronary bifurcation angioplasty „BOTTLE®”

– coronary bifurcation stent system „BIOSS®”– coronary angioplasty catheter „RIVER®” – Neuroprotection system „Robin®”

2011 – paclitaxel eluting coronary bifurcation stent system „BIOSS Expert®”– paclitaxel eluting cobalt-chromium coronary stent system „Paxel®”– sirolimus eluting coronary bifurcation stent system „BIOSS LIM®”– coronary stent system „Flexus®” – sirolimus eluting coronary stent system „Prolim®”– sirolimus eluting coronary stent system „Carlo S®”– cobalt-chromium coronary stent system „Coflexus®”– sirolimus eluting cobalt-chromium coronary stent system „Alex®”

2013 – self-expanding carotid stent „MER” – SOON!– paclitaxel coated angioplasty balloon – SOON!– temporary bipolar pacing electrode – SOON!

Page 4: English balton product training
Page 5: English balton product training
Page 6: English balton product training

Stent material steel 316 L

Stent design closed cell

Strut thickness 0.12 mm

Stent diameter 2.00 – 5.00 mm

Stent length 8 - 40 mm

MRI safe

Use with guide wire .014”

Use with guiding catheter 5F*

Length reduction after deployment <0.5%

Recoil <2%

Stent crimped profile .038”/0.97 mm**

Distal shaft diameter 2.7F/0.90 mm

Proximal shaft diameter 2F/0.65 mm

Nominal pressure/RBP 10 atm/16atm

Delivery system type Rapid Exchange

Delivery system length 140 cm

*for stent diameter 4.5 and 5.0 mm use guiding catheter 6F**for stent diameter 3mm

Page 7: English balton product training

Events n=97

Death 0 (0%)

Emergent CABG 2 (1.9%)

TLR* 22 (22.6%)

Revascularization per patient 0.24

Cumulative MACE 24 (24.7%)

Late thrombosis 0 (0%)

STENT REGISTRY - CLINICAL OUTCOMES AFTER 6 MONTHS

*clinically driven

Page 8: English balton product training

STENT REGISTRY – QCA AFTER 6 MONTHS F-UP

Baseline Afterimplantation

6 month f-up

RD (mm) 2.75 ± 0.61 3.05 ± 0.55 2.80 ± 0.59

MLD (mm) 1.31 ± 0.52 2.67 ± 0.58 2.32 ± 2.12

%DS 61.3 ± 25.9% 12.1 ± 10.9% 25.6 ± 19.0 %

AG/LL AG=1.35 mm LL=0.58 mm

Restenosis 13 (14.7%)

p=0.0001 p=0.18

Page 9: English balton product training
Page 10: English balton product training
Page 11: English balton product training

World in year

At the same time, foresighting problems with biotolerance ofbiostable polymers in the blood environment, Balton createsWorld’s first coated with biodegradable polymer Drug ElutingStent with paclitaxel – Luc-Chopin2 . The idea of the coating andstent itself were presented on TCT 2005.Unlike some biostable coatings, Luc-Chopin2 coating is fullybioacceptable and biodegradable with no harm to human body

Drug Eluting Stents are capturing the world market. Polymer drug carrier in those stents is biostable/non-biodegadable polymer

Poland

2003

Based on clinical trial results of Drug Eluting Stents:In some cases DES coated with nondegradable coatings can cause late inflammatory response, late and very late thrombosis.

11

World: 2007

Page 12: English balton product training

PLGACo-polymer

Physical Properties

Combination of polilactideand polyglicolyc polymers-Inert-flexible, ductable-thin, with high drugloading capacity

Manufacturability

High stabilityof the manufacture process

Controlled degradation time = controlled drug release

Mechanical integrity

Biocompatibility

Low thrombogenicityand inflamation

Strong adhesion to stent

PLGA degradates in 8 weeks releasing CO2 and H2O only

Stent surface after 1 week Stent surface after 8 weeks

Page 13: English balton product training

Luc-Chopin2 stent and its outstanding performance (based on clinical trial results)was appriciated by the 12th International Local Drug Delivery MeetingConference Board with 1st Prize of Conference, Geneva, Swiss, 2006

13

Page 14: English balton product training

Anti-proliferative agent paclitaxel (< 2µg/mm2)

Polymer Biodegradable

Stent diameter 2.00 – 5.00 mm

Stent length (mm) 8 – 40 mm

Stent platform stainless steel 316L

Strut thickness 0.12mm

Designclosed cell - for uniform drug distribution and coverage of the vessel wall

Ferromagnetism none

MRI safe

Use with guide wire max .014”

Use with guiding catheter 5F*

Length reduction after deployment <0.5%

Recoil <2%

Stent crimped profile .040” **

Distal shaft diameter 2.7F/0.90 mm

Proximal shaft diameter 2F/0.65 mm

Nominal pressure / RBP 10 atm / 16 atm

Delivery system length 140 cm

Delivery system type Rapid Exchange*for stent diameter 4.5 and 5.0 mm use guiding catheter 6F**for stent diameter 3mm

Page 15: English balton product training

MACE after 12 months follow-up

7.8% 8.5% 9.7%

Despite that 47% of the treated lesionswere B2 and C type, MACE resultsafter 12 months in Luc-Chopin2

patientsare better than in comparable stents

B2B2AA

39.1

42.6

10.4

7.9

CC

B1B1

Type of lesions

Clinical trial results

Page 16: English balton product training

CONCLUSIONS

Coronary stenting with a LUC-Chopin is safe, withvery low complication rate

Biodegradable polymer guarantee safety- there wereno late stent thrombosis

Late loss and MACE rate after 9 and 12 monthsfollow-up was low and comparable to other DESescurrently available on the market

…”Conceptually, use of biodegradable polymer whose duration on the stent surface matches the period of antirestenotic action of the drug may provide improved safety profile by reducing late events related to persistent presence of polymer on the surface of the first-generation stents. It may consequently also shorten the obligatory period of double antiplatelet therapy, enhancing overall clinical and economical benefit”…

Page 17: English balton product training
Page 18: English balton product training

Meeting the medical market requirements: Balton creates Cobalt-Chromium stent KOS

Safety & Efficacy registry launches on KOS project

January 2006 – KOS Clinical Trial final report

Safety and efficacy of Balton’s Cobalt-Chromium stent KOShas been proven

18

Year 2005

CORONARY STENT

Page 19: English balton product training

Advantages of KOS stents

•High radial strength•Enhanced visibility•Low profile with good flexibility and curve conformity •Safety and biocompatibility

*for stent diameter: 3mm

Stent material cobalt-chromium alloy L605

Stent nominal diameters 2.00 mm – 5.00 mm

Stent nominal lengths 8 mm – 40 mm

Wall thickness 0.080 mm

X-ray visibility Very good

Ferromagnetism none

MRI safe

Use with guide wire max. .014”

Use with guiding catheter 5F

Radial force high

Trackability and manouverability excellent

Stent crimped profile .036”

Distal shaft diameter 2F / 0.65 mm

Proximal shaft diameter 2.7F / 0.90 mm

Nominal pressure / RBP 10 atm / 16 atm

Delivery system type Rapid Exchange

Delivery system length 140 cm

Page 20: English balton product training

20

Page 21: English balton product training

®

small profile

0.036”

Page 22: English balton product training

Stent material 316L stainless steel

Stent nominal diameters 2.00 mm – 5.00 mm

Stent nominal lengths 8 mm – 40 mm

Wall thickness 0.115 mm

X-ray visibility very good

Ferromagnetism none

MRI safe

Use with guide wire max. .014”

Use with guiding catheter 5F

Radial force high

Trackability and manuverability excellent

Stent crimped profile .036”

Proximal shaft diameter 1,8F / 0.60 mm

Distal shaft diameter 2.5F / 0.84 mm

Nominal pressure / RBP 8 atm / 16 atm

Delivery system type Rapid Exchange

Delivery system length 140 cm

®

Page 23: English balton product training

Sirulimus eluting coronary stent

®

small profile

0.038”BIODEGRADABLE

POLYMER

Page 24: English balton product training

Anti-proliferative agent Sirolimus

Polymer biodegradable

Paltform Flexus

Material 316L stainless steel

Stent diameter 2.00 mm – 5.00 mm

Stent length (mm) 8 mm – 40 mm

Strut thickness 0,115 mm

Ferromagnetism none

MRI safe

Use with guide wire max. .014”

Use with guiding catheter 5F

Length reduction after deployment <0.5%

Recoil Less than 2%

Crimped Stent profile .038”

Proximal shaft diameter 1.8F / 0.60 mm

Distal shaft diameter 2.5F / 0.84 mm

Nominal pressure / RBP 8 atm / 16 atm

Delivery system type Rapide Exchange

Delivery system length 140 cm

®

Page 25: English balton product training

®

Anti-proliferative agent Sirolimus

Polymer biodegradable

Platform Chopin 2

Material 316L stainless steel

Stent diameter 2.00 mm – 5.00 mm

Stent length (mm) 8 mm – 40 mm

Stent platform 316LVM stainless steel

Strut thickness 0,12 mm

Ferromagnetism none

MRI safe

Use with guide wire max. .014”

Use with guiding catheter 5F

Crimped Stent profile .040”

Proximal shaft diameter 2,0F / 0.65 mm

Distal shaft diameter 2.7F / 0.90 mm

Nominal pressure / RBP 10 atm / 16 atm

Delivery system type Rapide Exchange

Delivery system length 140 cm

Page 26: English balton product training

®

very small profile

0.032”

Page 27: English balton product training

Stent material cobalt-chromium alloy L605

Stent nominal diameters 2.00 mm – 5.00 mm

Stent nominal lengths 8 mm – 40 mm

Wall thickness 0.070 mm

X-ray visibility Very good

Ferromagnetism none

MRI safe

Use with guide wire max. .014”

Use with guiding catheter 5F

Radial force high

Trackability and manouverability excellent

Stent crimped profile .032”

Proximal shaft diameter 1,8F / 0.60 mm

Distal shaft diameter 2.5F / 0.84 mm

Nominal pressure / RBP 8 atm / 16 atm

Delivery system type Rapid Exchange

Delivery system length 140 cm

®

Page 28: English balton product training

®

very small profile

0.034”

BIODEGRADABLE POLYMER

Page 29: English balton product training

Stent material cobalt-chromium alloy L605

Polymer biodegradable

Anti-proliferative agent Paclitaxel

Platform Coflexus

Stent nominal diameters 2.00 mm – 5.00 mm

Stent nominal lengths 8 mm – 40 mm

Wall thickness 0.070 mm

X-ray visibility very good

Ferromagnetism none

MRI safe

Use with guide wire max. .014”

Use with guiding catheter 5F

Radial force high

Trackability and manouverability excellent

Stent crimped profile .034”

Proximal shaft diameter 1,8F / 0.60 mm

Distal shaft diameter 2.5F / 0.84 mm

Nominal pressure / RBP 8 atm / 16 atm

Delivery system type Rapid Exchange

Delivery system length 140 cm

®

Page 30: English balton product training

®

very small profile

0.034”BIODEGRADABLE

POLYMER

Page 31: English balton product training

Stent material cobalt-chromium alloy L605

Polymer biodegradable

Anti-proliferative agent Sirolimus

Platform Coflexus

Stent nominal diameters 2.00 mm – 5.00 mm

Stent nominal lengths 8 mm – 40 mm

Wall thickness 0.070 mm

X-ray visibility Very good

Ferromagnetism none

MRI safe

Use with guide wire max. .014”

Use with guiding catheter 5F

Radial force high

Trackability and manouverability excellent

Stent crimped profile .034”

Proximal shaft diameter 1,8F / 0.60 mm

Distal shaft diameter 2.5F / 0.84 mm

Nominal pressure / RBP 8 atm / 16 atm

Delivery system type Rapid Exchange

Delivery system length 140 cm

®

Page 32: English balton product training

®

®

®

Page 33: English balton product training

®

®

®

Page 34: English balton product training

Bioss stent is a innovative and technologically advanced solution for bifurcations treatment

EASY IMPLANTATION

•Unique configuration of the delivery system ensures safety and efficacy during the Bioss stent

implatation procedure

• Worlds’ first dedicated for bifurcation delivery system guided on single guide wire

• One special balloon with two diameters corrensponding to main vessel and main branch diameters

Bioss international patent pending

PROXIMAL SEGMENTDISTAL SEGMENT

LARGE STENT CELL

PROXIMALDIAMETER

DISTAL DIAMETER

International patent pending

Page 35: English balton product training

IMPORTANT: mid marker shall be placed in linewith carina tip

You will earn:-Anatomically fitted stent which correspondwith physiological vessel diameters- Not disturbed SB blood flow-Easy access to SB through large stent cell

Bioss international patent pending

Mid –marker of the delivery system

®

Page 36: English balton product training

Stent total length[mm]

Proximal diameter[mm]

Distaldiameter

[mm]

15.00

4.50 3.754.25 3.503.75 3.003.50 3.003.50 2.753.25 2.50

18.00

4.50 3.754.25 3.503.75 3.003.50 3.003.50 2.753.25 2.50

23.00

4.50 3.754.25 3.503.75 3.003.50 3.003.50 2.753.25 2.50

International patent pending

® ® ®

Page 37: English balton product training

Large cell of the stent in place of side branch entrance gives possibility to enter the SB with any standard size conventional stent

Implant construction allows Bioss stent adjust to vessel curvature

Precise implantation of Bioss family stents against carina tip is ensured by three radiopaque markers

Front view

Lateral view

®

Page 38: English balton product training

ANGIOPLASTY BALLOON CATHETER FOR BIFURCATION LESIONS

Angioplasty balloon catheter Bottle is design for:1. Bifurcation optimization after deplyment of classic stent2. Angioplasty of bifurcation coronary stenosis

®

Page 39: English balton product training

ANGIOPLASTY BALLOON CATHETER FOR BIFURCATION

®

5F

Page 40: English balton product training

Balloon diameter 1.25 – 5.0 mm

Balloon length 10 - 40 mm

Use with guiding catheter

For balloon diameter 1.5 – 4.0mm 5F

Use with guidingcatheter

For balloon diameter 4.5 – 5.0mm 6F

Crossing profile 0.026”

Nominal pressure 10 atm

Rated Burst Pressure

RBP16 atm

Catheter length 140 cm

Delivery system type RX

CORONARY ANGIOPLASTY CATHETERCORONARY ANGIOPLASTY CATHETER

Page 41: English balton product training

• a low-profile angioplasty balloon catheter dedicated for narrow and tortus vessel

• high flexibility

• excellent pushability and manouverability

®

Page 42: English balton product training

diameters 1,25 – 4,0 mm

lenghts 10 - 40 mm

Material nylon

Catheter coating Hydrophilic

Entry profile 0.017” (0,43 mm)

Crossing profile 0.025” (0,63 mm)

Proximal diameter 1.8F (0,60 mm)

Dital catheter part diameter 2.5F (0.84 mm)

Pushability and manouverability excellent

Inflation / deflation time Very short

Guide wire max. 0.014”

Minimal guiding catheter OD/ID 5F / 0.056”

Nominal pressure 8 atm

RBP 16 atm

Catheter lenght 140 cm

Delivery system type Rapid Exchange

®

Page 43: English balton product training

Sample

Max Force for insertion

through 90°(grams)

Max Force for retraction

through 90°(grams)

Balton 8.71 -17.48Maverick 11.90 -20.79Sprinter 11.61 -22.47

Standarized FDA pushability test

®

River Maverick Sprinter

Page 44: English balton product training

CatalogueNo.

Filtering basket diameter

[mm]

Recommendedfor vesseldiameter

Guide wirelength[cm]

SDN4RX 4 .014” 170

SDN5RX 5 .014” 170

SDN6RX 6 .014” 170

SDN7RX 7 .014” 170

SDN8RX 8 .014” 170

Rapid Exchange

CatalogueNo.

Filtering basket diameter

[mm]

Recommendedfor vesseldiameter

Guide wirelength[cm]

SDN4OTW 4 .014” 300

SDN5OTW 5 .014” 300

SDN6OTW 6 .014” 300

SDN7OTW 7 .014” 300

SDN8OTW 8 .014” 300

Over the wire

Two delivery & capture system types

Filtering basket made of biocompatible materials;

filter holes diameter: 100÷120 µm

PTFE .014” guide wire integrated with filtering basket

Atraumatic, flxible end-tip of the guide wirefacilitates safe reaching of the area beyond lesion

outstanding X-ray visibility

®

Page 45: English balton product training

PERIPHERAL STENTSPERIPHERAL STENTS

Page 46: English balton product training

Stent for renal arteries with RX delivery system

Material 316 stainless steel

Guide wire max .014”

Guiding catheter 6F

Nominal pressure 8 atm

Rated burst pressure 12 atm

Available diameters 5.0 – 7.0mm

Lengths 8.0 – 22.0mm

Delivery system type Rapid Exchange

World’s first renal stent with Rapid Exchange delivery system

Year 2004

Page 47: English balton product training

Stent diameter 4 - 10 mm

Stent length 16 - 100 mm

Use with guide wire

.035”

Use with introducer

for stent diameter 4 – 6 mm 6F

Use with introducer

for stent diameter 7 – 9 mm 7F

Use with introducer

for stent diameter 10 mm 8F

Nominal Pressure 6 atm

Rated Burst Pressure

10 atm

Catheter length 80 or 110 cm

Delivery system type

OTW

STENT FOR PERIPHERAL VESSELSWITH DELIVERY SYSTEM

Page 48: English balton product training

Curiosity:

NITINOL – discovered during research. at the U.S. Naval Ordnance Laboratory in 1962.

The new concept of self-expandable stent:Simple in design - simple in usePossibility of reposition effects in best efficecy for patients

• Constructed from Nitinol wire (NiTi) – material with higher biocompatibility leveland corrosion resistance than medical AISI 316L stainless steel

• Made in one-wire technology, without any welds and solders

• Special construction of the delivery system make to correction of stent position inside a vessel possible even after the partial stent release

• Elevated ends of the stent eliminating „fish mouth” effect and stent migration

• High radial force

• High flexibility of the JaguarSM stent effects in excellent adaptation to vessel curvature

Year 2003

48

SELF EXPANDING NITINOL STENT WITH DELIVERY SYSTEM

Page 49: English balton product training

SELF EXPANDING NITINOL STENT WITH DELIVERY SYSTEM

The JaguarSM self-expanding stent with a delivery system isrecommended for percutaneous intravascular deployment inpatients with atherosclerotic, radiation and trauma-inducedstenoses.

The soft and rounded tip of delivery system is atraumatic towardsthe arterial wall.

Nominal stent diameters 4 – 14 mm

Nominal stent lengths 15 – 150 mm

Available delivery system length 80 or 135 or 165 cm

Guide wire and stent diameters for delivery system 6F.018”

4 – 10 mm.035”

Guide wire and stent diameters for delivery system 7F .035” 6 – 10 mm

Guide wire and stent diameters for delivery system 8F .035” 12 - 14 mm

Delivery system type OTW

Page 50: English balton product training

PERIPHERAL ANGIOPLASTY CATHETER PBAPERIPHERAL ANGIOPLASTY CATHETER PBA

Balloon diameter 4 - 12 mm

Balloon length 20 - 100 mm

Use with introducer For balloon diameter 4 – 7 mm 6F

Use with introducer For balloon diameter 8 – 10 mm 7F

Use with introducer For balloon diameter 12 mm 8F

Nominal pressure 6 atm

Rated Burst Pressure

RBP10 atm

Catheter length 80 or 110 cm

Type of delivery system

OTW

Page 51: English balton product training

They feature high functional parameters quality:- Thin walls, allowing maximum flow.- High pressure resistant 100 atm (1450PSI).- Relevant softness, flexibility and curvature, facilitating catheter introduction

and advancement.- Good visibility in X-rays.- Perfectly smooth surface and very good finishing of side holes.- Atraumatic tip.

Each catheters features a Luer-Lock connector, making the set hermetic.Some catheters size 5F and 6F are available in reinforced configuration with

stainless steel braided.All catheters feature the same softness in distal parts (unbraided).

CATHETERS FOR ANGIOGRAPHYCATHETERS FOR ANGIOGRAPHY

Page 52: English balton product training
Page 53: English balton product training

Cataloque No.

Balloonnominaldiameter

[mm]

Balloonnominal

lengtht [mm]

Catheterlenght

VALP5x2070 5 20 70 cm

VALP8x2070 8 20 70 cm

VALP10x4070 10 40 70 cm

VALP12x4070 12 40 70 cm

VALP15x2570 15 25 70 cm

VALP15x4070 15 40 70 cm

Page 54: English balton product training

Cataloque No.

Balloonnominaldiameter

[mm]

Balloonnominallengtht[mm]

Catheterlenght

VAL15x40110 15 40 110 cm

VAL18x40110 18 40 110 cm

VAL20x45110 20 45 110 cm

VAL23x45110 23 45 110 cm

VAL25x50110 25 50 110 cm

VAL28x60110 28 60 110 cm

VAL30x60110 30 60 110 cm

VAL35x60110 35 60 110 cm

VAL40x60110 40 60 110 cm

Page 55: English balton product training

Balloon with a soft tip at the distal end of the double lumen catheter – for easy introductionthrough the femoral artery

Catheter with a X-Ray visible markers - for precise determination of the balloon location

Sets compatible with DataScope and Arrow pumps

Balloon volume 20 – 50 ml

Balloon length 170 – 260 mm

Balloon diameter volume and lenght dependent

Shaft size 7F or 7.5F or 8F

Guide wire diameter .025”

IABC Insertion length 765 mm

Page 56: English balton product training
Page 57: English balton product training

Catalogue

No.

Sheath

Size / lengthCup colour Dilatator size

Angiographic

needle size

Guide wire

Size / length / type

INT3F 3F / 60 mm white 3F 21G .018” / 35 cm / STRAIGHT

INT4F 4F / 70 mm red 4F 19G .022” / 40 cm / “J”

INT5F 5F / 110 mm gray 5F 18G .035” / 40 cm / “J”

INT6F 6F / 110 mm green 6F 18G .035” / 40 cm / “J”

INT7F 7F / 110 mm orange 7F 18G .035” / 40 cm / “J”

INT8F 8F / 110 mm blue 8F 18G .035” / 40 cm / “J”

INT9F 9F / 110 mm black 9F 18G .035” / 40 cm / “J”

INT10F 10F / 110 mm white 10F 18G .035” / 40 cm / “J”

INT12F blue blue 12F 18G .035” / 40 cm / “J”

INT14F 14F / 110 mm blue 14F 18G .035” / 40 cm / “J”

INT16F 16F / 110 mm blue 16F 18G .035” / 40 cm / “J”

Set contains

sheath with valve angiographic needle guide wire dilator

Special order can contain braided introducer with radiopaque markerModel reference number:INT8FM – introducer with a markerINT6FT – braided introducer

Page 58: English balton product training

Catalogue

No.

Sheath

Size / lengthCup colour

Dilatator

size

Angiographic

needle size

Guide wire

Size / length / type

INT3FK 3F / 60 mm white 3F 21G.018” / 35 cm /

PROSTY

INT4FK 4F / 70 mm red 4F 19G .022” / 40 cm / “J”

INT5FK 5F / 110 mm gray 5F 18G .035” / 40 cm / “J”

INT5FK23 5F / 230 mm gray 5F 18G .035” / 60 cm / “J”

INT6FK 6F / 110 mm green 6F 18G .035” / 40 cm / “J”

INT6FK23 6F / 230 mm green 6F 18G .035” / 60 cm / “J”

INT7FK 7F / 110 mm porange 7F 18G .035” / 40 cm / “J”

INT7FK23 7F / 230 mm porange 7F 18G .035” / 60 cm / “J”

INT8FK 8F / 110 mm blue 8F 18G .035” / 40 cm / “J”

INT8FK23 8F / 230 mm blue 8F 18G .035” / 60 cm / “J”

INT9FK 9F / 110 mm black 9F 18G .035” / 40 cm / “J”

INT10FK 10F / 110 mm white 10F 18G .035” / 40 cm / “J”

Set contains

sheath with valve angiographic needle guide wire dilator

Special order can contain braided introducer with radiopaque markerModel reference number:INT8FKM – introducer with a markerINT6FKT – braided introducer

Page 59: English balton product training

Guide wire of special construction:•Soft, distal part of guide wire - enablesto reduce it to the vessel•Stiff, proximal part – provide an excellent scaffold for dilator along withpreventing from vessel perforation

Distal part of the sheath and of dilator is finished in the way thatenables easy and atraumaticintroduction of the catheter to thevessel

Catalogue

No.

Sheath

Size / lengthCup colour

Dilatator

size

Angiographic

needle size

Guide wire

Size / length / type

INT5FKR 5F / 110 mm gray 5F 21G .018” / 45 cm / “J”

INT5FKRP 5F / 110 mm gray 5f 21G .018” / 45 cm / straight

INT5F21KR 5F / 110 mm gray 5F 21G .021” / 45 cm / “J”

INT5F21KRP 5F / 110 mm gray 5F 21G .021” / 45 cm / straight

INT5FKR23 5F / 230 mm gray 5F 21G .018” / 50 cm / “J”

INT5FKR23P 5F / 230 mm gray 5f 21G .018” / 50 cm /straight

INT5F21KR23 5F / 230 mm gray 5F 21G .021” / 50 cm / “J”

NT5F21KR23P 5F / 230 mm gray 5F 21G .021” / 50 cm / straight

INT6FKR 6F / 110 mm green 6F 21G .018” / 45 cm / “J”

INT6FKRP 6F / 110 mm green 6F 21G .018” / 45 cm / straight

INT6F21KR 6F / 110 mm green 6F 21G .021” / 45 cm / “J”

INT6F21KRP 6F / 110 mm green 6F 21G .021” / 45 cm / straight

INT6FKR23 6F / 230 mm green 6F 21G .018” / 50 cm / “J”

INT6FKR23P 6F / 230 mm green 6F 21G .018” / 50 cm /straight

INT6F21KR23 6F / 230 mm green 6F 21G .021” / 50 cm / “J”

NT6F21KR23P 6F / 230 mm green 6F 21G .021” / 50 cm / straight

INT7FKR 7F / 110 mm orange 7F 21G .018” / 45 cm / “J”

INT7FKRP 7F / 110 mm orange 7F 21G .018” / 45 cm / straight

INT7F21KR 7F / 110 mm orange 7F 21G .021” / 45 cm / “J”

INT7F21KRP 7F / 110 mm orange 7F 21G .021” / 45 cm / straight

INT7FKR23 7F / 230 mm orange 7F 21G .018” / 50 cm / “J”

INT7FKR23P 7F / 230 mm orange 7F 21G .018” / 50 cm /straight

INT7F21KR23 7F / 230 mm orange 7F 21G .021” / 50 cm / “J”

NT7F21KR23P 7F / 230 mm orange 7F 21G .021” / 50 cm / straight

RADIAL ARTERY INTRODUCERSFOR CARDIOLOGY

Page 60: English balton product training

GUIDEWIRESGUIDEWIRES

For interventional cardiology & radiologyThe tip of the guidewire is appropriately shaped andatraumatic for optimal patient's security Designed for complex vascular interventions including"cross-over" techniques.

Guidewires Size

Steel guidewires .022”, .035”, .038”

Hydrophilic guidewires .032”, .035”, .038”

Micro guidewires .007”, .009”, .014”

Lunderquist guidewires .035”

PTFE coated guidewires .018”, .022”, .025”, .035”, .038”

PTCA guidewire „Rider” .014”

Page 61: English balton product training

PTCA GUIDE WIRES „RIDER” WITH HYDROPHILIC COATINGPTCA GUIDE WIRES „RIDER” WITH HYDROPHILIC COATING

• Material: steel and platinum• Length 175 -300 cm• Broad range of stiffness• Radiopaque marker of min. 25 mm length• Straight and "J" shaped guide wire tips• Excellent steerability• Special coating for optimal crossing of tortuous and narrow vessels• Stiff proximal shaft• Good visibility of guide wire tip• Optimal torque control 1:1

The guide wires are available in several kinds of flexibility of the distal tip:• with high floppy tip – HF• with floppy tip - F, • with medium tip - M, • with stiff tip – S• with high stiff tip – HS

Guide wires are available with additional strengthening in their proximal spiral part, which enables them for the delivery of stents:• stent support floppy – STF• stent support medium – STM• stent support stiff – STS.

Guidewire Size Length Type

PTCAguidewires

.014” 175 – 300 cm„J”

Straight

Page 62: English balton product training
Page 63: English balton product training

Large vessel catheterization set with:- Single lumen catheter- Double lumen catheter- Triple lumen catheter- Four lumen catheter

Anaesthesia sets

Spinal anaesthesia needles

Thermodilution set “BALKAT”

Page 64: English balton product training
Page 65: English balton product training
Page 66: English balton product training
Page 67: English balton product training

ENDOSCOPIC BALLOON DILATION CATHETER

FOR ESOPHAGEAL, PYLORIC AND COLONIC

ONE BALLOON – THREE DIFFERENT DIAMETERS AT THREE SEPARATE PRESSURES

•Compatible channel of endoscope 2.8 mm or larger

•Very good visibility in fluoroscopy

•Very short deflation time

•Usable with 60 ml inflation device (available in Balton product range)

•Guide wire type catheters are intended to be use with specially designed

PTFE coated Balton guide wires - ensures safety and easy use of the

endoscopic balloon catheter

Page 68: English balton product training

ENDOSCOPIC BALLOON DILATION CATHETER

Ensures safety and easy use of the endoscopic balloon catheter

Appropriate 60 ml pressure inflator for Troyca catheters can be found in our portfolio

SPECIALLY DESIGNED PTFE GUIDE WIRES FOR TROYCA CATHETERS

Page 69: English balton product training

Embolectomy catheters

Aortic catheters

Catheter for bile duct’s

Drains

Page 70: English balton product training
Page 71: English balton product training

- Nephrostomy sets

Nephrostomy & cystostomy set

- Cystostomy sets

- Ureteral catheters

- Sets for stent introduction

Page 72: English balton product training
Page 73: English balton product training

Insemination catheters

Histerosalpingography sets

HSG catheters

Page 74: English balton product training

Accessories

Page 75: English balton product training

Rotating „Y”

Manifolds

Torquers

Stopcocks

Connectors

Page 76: English balton product training

High pressure inflators

Syringe volume: 20 mlMax. pressure: 30 atm

Syringe volume: 25 mlMax. pressure :30 atm

Syringe volume: 30 mlMax. pressure: 30 atm

Syringe volume: 60 mlMax. pressure: 15 atm

Page 77: English balton product training