EN10255_DIN 2440 - Tevi OL Instalatii
Click here to load reader
-
Upload
alex-catanescu -
Category
Documents
-
view
27 -
download
12
Transcript of EN10255_DIN 2440 - Tevi OL Instalatii
-
15
Medium-weight threaded steel tubes - EN 10255/DIN 2440Application: air, water, non-aggressive gas and uid transportation.
Pipe dimensions and weight
Nominal size, DN Outside diameter, mm Wall thickness, mm Weight per meter, kg/m15 21.3 2.65 1.2220 26.9 2.65 1.5825 33.7 3.25 2.4432 42.4 3.25 3.1440 48.3 3.25 3.6150 60.3 3.65 5.1065 76.1 3.65 6.5180 88.9 4.05 8.47
100 114.3 4.5 12.1
Tolerances
Nominal outside diameter, mm
Outside diameter, mmWall thickness permissible deviation, %
Maximum Minimum21.3 21.8 21.0
-12.5 (for areas of the pipe of length less than 2Ddeviation of minus 15% is acceptable).Positive deviation is limited by weight of the pipe
26.9 27.3 26.533.7 34.2 33.342.4 42.9 42.048.3 48.8 47.960.3 60.8 59.776.1 76.6 75.388.9 89.5 88.0
114.3 115.0 113.1
Mechanical properties of steel
Steel Grade Wall thickness,mmTensile strength,N/mm (Mpa)
Yield strength, N/mm not less than
Elongation,%, not less than
S185Less than 3 310-540 (31.6-55.1)
185 (18.9)14
3 and above 290 (29.6) and above 18
Heavy-weight threaded steel tubes - EN 10255/DIN 2441Pipe dimensions and weight
Nominal size, DN Outside diameter, mm Wall thickness, mm Weight per meter, kg32 42.4 4.05 3.8440 48.3 4.05 4.4350 60.3 4.50 6.1765 76.1 4.50 7.9080 88.9 4.85 10.1
100 114.3 5.40 14.4
Tolerances
Nominal outsidediameter, mm
Outside diameter, mmPermissible deviation for wall thickness, %
Maximum Minimum42.4 42.9 42.0
-12.5 (for areas of the pi pe with length less than 2Ddeviation of minus 15% is acceptable).Positive deviation is limited bypi pe weight
48.3 48.8 47.960.3 60.8 59.776.1 76.6 75.388.9 89.5 88.0
114.3 115.0 113.1
Mechanical properties of steel
Steel Grade Tensile strength, N/mm (Mpa) not less thanYield strength, N/mm (Mpa) not less than Elongation, %
S185 290 (29.6) 185 (18.9) 18