Contents
Self-contained emergency lighting
Self-contained monitoring systems 8 - 23
Self-contained emergency luminaires 24 - 111
Self-contained emergency conversion kits 112 - 121
Central and group battery systems
Central battery systems (CPS) 122 - 140
Group battery systems (LPS) 141 - 157
Luminaires for central emergency power supply 158 - 239
Standards and regulations 240 - 267
Planning 268 - 269
Appendix 270 - 288
Service 272 - 273
EVG symbol 274
LED symbol 275
Catalogue number codes 276
Motifs and lettering for emergency luminaires 277
Motifs and lettering for luminaire signs 278 - 279
Lamps 280
Terms and conditions of sale and delivery 281
Catalogue number index 282 - 286
Alphabetical index 287 - 288
Technical support 289
After sales service 289
Contact for emergency lighting 289
2
New products
Self-contained moni-toring systems
Self-contained emer-gency luminaires
Self-contained emer-gency conversion kits
SINGLE BATTERY
10 18 2214
118116 - 117114 116 - 117
28, 30 - 31 28, 30 - 31 32
44, 47 50 52
38
40 - 4340 - 43
74
54, 56 - 57 54, 58 - 59 54, 58 - 59
76 - 79
94 96
64 6866
44, 45
26 28 - 29
44, 46
60
54, 55
70 72
62
88
10290 10492 10098
80 - 83 84 86
3634
106 110110108
LED LED LED
LED LED
LEDLEDLED
LED LED
LED
LED
LED LED
LED
LED LED LED
8h 8h
8h8h8h
8h
8h
33
New products
Luminaires for central emergency
power supply
Central battery systems (CPS)
Group battery systems (LPS)
CENTRAL BATTERY
132
144
138128
142
162, 164 162, 165 166
182 - 185 186 188, 189
172 - 174
176, 177172 - 174
216
188, 192 194 196
218
202
206
204
176, 178
168160 162 - 163
176, 179
170
198
188, 190
188, 192
208 - 210 212 - 214
200
228 236 238230 234230
222
232
220 224
226
LED LED LED LED LED
LED LED
LED LED
LED
LED LED LED
LED
LED
LED LED LED
4
A view of our plant and its solar panels.Solar panel surface: 30,000 square meters Number of modules: 5,000Output: more than 1.1 megawatts Greenhouse gas savings: 930,000 kilograms per year
About us
We have been making luminaires of exceptional
quality for more than seven decades. At RZB,
our daily activities center around the nowadays
often mentioned subjects of innovation, quality,
design, energy efficiency, environmental friend-
liness and customer service.
Our luminaires are manufactured using the most
advanced production technologies available
today. These products combine outstanding
innovation with the latest lighting technologies;
and the fact that we operate our own R&D
lab guarantees that all of our products comply
strictly with all applicable legal regulations.
The designs of our luminaires combine optimal
technical characteristics and exemplary func-
tionality, thus enabling us to offer our custom-
ers the best possible luminaires and lighting
solutions. The use of select materials and our
ISO 9001:2000 quality assurance system are
your guarantee of the outstanding quality and
exceptionally long service life of our luminaires.
This applies in particular to the plastics, die-
cast components, luminaire glasses, and sur-
face coatings used in our products.
Many items in our portfolio are on hand at all
times, thanks to our highly efficient logistics
workflows and the fact that we keep a great
number of components and finished products
always in stock.
We also provide presales advice, lighting system
planning services, demos and workshops.
5
Improved light source energy efficiency, lamps
miniaturization, and the dizzying pace of
advances in LED technology are the challenges
currently facing the luminaire industry today,
particularly in view of the fact that lighting
accounts for 20 percent of worldwide energy
consumption.
The manufacture of incandescent light bulbs has
been phased out by law in the EU, thus making
it more urgent than ever for the European light-
ing industry to develop luminaires that use new
types of more energy efficient lamps.
Energy efficiency without dimming the lights
Another environmental aspect that plays a key
role in designing and developing our luminaires
is the use of extremely high quality materials,
which are selected with durability, environmen-
tally friendly manufacturing, and recyclability
firmly in mind. This is our way of making a last-
ing contribution to environmental stewardship.
Environmental stewardship
6
Quality
Our quality assurance system is DIN EN ISO
9001: 2000 compliant.
Photometry lab Heat measurement lab EMC lab Protection type testing
Memberships in industry organizations
7
RZB emergency lighting: the smart choice
All your luminaire needs from a single vendor
We offer a complete range of emergency and
general lighting products. This means that we
can offer you integrated solutions for both
types of applications – which in turn saves you
the trouble of dealing with other vendors.
Reliability
Our luminaires integrate extremely reliable elec-
tronics and are highly durable thanks to the
use of exceptionally high quality electronic
components and high tech LED lamps – not to
mention our extensive testing program, whose
scope far exceeds the statutory minimum.
Lighting technology
The luminaires that we develop in our state of
the art lab meet all applicable industry stand-
ards. In emergency situations, our emergency
luminaires enable building occupants to exit
the building safely. And what’s more, the use
of high tech LEDs allows for greatly reduced
energy consumption.
Superior quality luminaires and luminaire designs
We use the most advanced manufacturing technologies available and adhere to an extremely high develop-
ment standard. We have more than three decades of experience in the use of high tech materials and the
development of systems that allow for continuous improvement in the efficiency of emergency lighting.
Installation
When developing our luminaires, we always keep
in mind the aspect of installation-friendliness,
thus guaranteeing rapid and simple handling
in building construction settings, thanks to the
use of elements such as plug-in connectors
and modular technologies.
Customer service
We offer comprehensive planning services for
customer specific emergency lighting systems,
and also provide support for the commission-
ing phase. Plus you can count on outstanding
after-sales service from our team of experi-
enced technicians and engineers.
Sustainability
Environmental sustainability is a top priority
for us in terms of not only the manufacturing
process, but also – and especially – the finished
product. All of our luminaires contain 100 percent
recyclable materials that are notable for their
exceptional durability and quality.
8
Monitoring system DALI MultiDigit® MWEBplus PZ 50
System structure modular modular single module single module
Colour display • – – –
Number of circuits, basic unit 2 1 1 1
Number of luminaires per circuit 64 125 125 50
Number of luminaires per basic unit max. 128 max. 125 max. 125 max. 50
Expandable•
max. 64 modules
•
max. 125 modules– –
Max. number of luminaires 4,096 15,625 125 50
Error visualisation Display LED LED LED
Potential-free contacts for error messages
accessories (optional) • • •
E-mail communication•
(optional)
•
(optional)• –
Network connection•
(optional)– – –
Modualr structure • • – –
Bus line topography free free free ring
Bus lineIY-ST(Y) 2 x 2 x 0.8
or NYMIY-ST(Y) 4 x 2 x 0.8 IY-ST(Y) 2 x 2 x 0.8 IY-ST(Y) 2 x 2 x 0.8
Installation environment small to large buildings
large to very large buildings
small to medium sized buildings small buildings
Type of installation Recessed wall installation, Surface wall installation top hat rail top hat rail top hat rail
Accessories Controller without displaySignal amplifier
MWEB– –
9
Self-contained monitoring systems
DALI monitoring system 10 - 13
MultiDigit® monitoring system 14 - 17
MWEBplus monitoring system 18 - 21
PZ 50 monitoring system 22 - 23
10
EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS
DALI interface
System benefits
- DALI monitoring units with touchscreen and logical menu guidance
- 2 circuits, with 64 luminaires each
- All luminaires with self-test function
- Lighting in complex building structures can easily be realized via network connection
- Visualisation of connected system(s) via TCP/IP (optional)
- Automatic generation of detailed log book
- Execution of all mandatory controls at minimum costs
- Programmable also via USB
- Formation of groups
- Preinstalled operating software
- System setup with software via USB
- Bidirectional communication between luminaire and touchscreen with status and error messages
- Easy to install, setup and maintain
- Bus structure: star-shaped, linear and tree-shaped
- Control line: DC-isolated and reverse voltage protected
- No specific bus line required
- Password protection
- Emergency lighting function disabled outside of normal operating hours
- No need to respect bus line polarity
Monitoring systems with
Please note:
All modules and luminaires for DALI must have order suffix (Y) .07
Easy to operate via touchscreen
11
LN
L
EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS
Tender texts available upon request | Specifications subject to alteration
DALI interfaceSystem description
This system is based on the DALI Standard (IEC 62034 and IEC 62386) and allows for central monitoring of up to 128 self-contained emergency luminaires.
It is operated and monitored via touchscreen (DALI control unit) with logical menu guidance for easy use.
The DALI control unit is housed in a high-quality metal casing for either surface wall installation or recessed wall installation.
By interconnecting more control units, the monitoring of emergency lighting systems can be easily realized even in complex building structures.
for this purpose the single DALI control units can be interconnected via an existing local network (TCP/IP), and the entire system can be operated and monitored from one central PC.
As an option it is also possible to control the system via internet.
The DALI control unit communicates continuously with the connected self-contained emergency luminaires and is thus able to immediately display any error.
The logical menu guidance provides the operator within a few steps detailed information concerning type and location of the respective error as well as further indications for error elimination, if applicable.
Automatic self-test function of the luminaires as well as generation of a detailed test log contribute notably to a reduction of time and costs for mandatory emergency lighting systems tests.
Luminaires / Modules: order suffix .07
Power supply: 230 V / 50-60 hz
Power supply (bus line): max. 250 mA, 22.5 V
Max. bus length: 300 m (between control unit and last luminaire)
Transfer rate: 1,200 Bit/s at a voltage level of 16 V
Monitoring system DALI985405 Surface L 148,5, B 92, h 60985406 Recessed L 148,5, B 92, h 8, hE 52, LA 135, BA 80
Surface wall installation Recessed wall installation
BUS port
Mains port
Ethernet
Rear view of DALI unit
DALI circuit 2
CAT. 5 Ethernet (network optional)
LPENDisable function (optional)
DALI circuit 1
BA
LA
LHE H
B
L
B
H
12
EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS
Tender texts available upon request | Specifications subject to alteration
Monitoring via DALI interface
general mains power supply
L
N
general mains power supply
L
N
general mains power supply
L
N
DALI Controller
max. 64 luminairesmax. 300 m
DALI BUS circuit 1
DALI BUS circuit 2
13
654321
NL`
LPE
654321
NL`
LPE
654321
NL`
LPE
654321
NL`
LPE
654321
NL`
LPE
654321
NL`
LPE
654321
NL`
LPE
654321
NL`
LPE
654321
NL`
LPE
654321
NL`
LPE
EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS
Tender texts available upon request | Specifications subject to alteration
Monitoring via DALI interface
Ethernet Switch
Mains 230 V
DALI BUS2 x 1.5 mm2
DALI module 1
DALI module 2
DALI module 3
DALI module 4
DALI module 64 DALI module 64
(depending on version)
(depending on version)
(depending on version)
(depending on version)
(depending on version)
DALI BUS-curcuit 1 Max. 64 luminaires Max. length: 300 m
DALI BUS-curcuit 2 Max. 64 luminaires Max. length: 300 m
DALI BUS 2 x 1.5 mm2
DALI module 1
DALI module 2
DALI module 3
DALI module 4
(depending on version)
(depending on version)
(depending on version)
(depending on version)
(depending on version)
14
EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS
MultiDigit®
System benefits
Continuous central local monitoring of all emergency luminaires using a normal PC, or intranet/internet-based monitoring using MWEB module (PC for system control can thus be eliminated).
- Automatic system configuration
- Plain-text reports of all malfunctions, with indication of failure location
- Coordination of self-test activation of all self-contained emergency luminaires
- Error message logs (PC and/or printer)
- Detailed information and control options for each single emergency luminaire
- Input port for evacuation function (fire brigade)
- Each signal amplifier is fitted with a tap for forwarding collective/group errors to superior systems
- Max. 15, 625 luminaires
Monitoring systems for large buildings
general circuit diagram for the MultiDigit® monitoring system
* The minimum cross-section of the bus line depends on the actual length of the bus line and the number of connected luminaires. Please consult the WINLink manual for detailed information on cable cross-sections.
No. 1
No. 1
No. 2
No. 2
No. 3
No. 3
No. 4
No. 4
Signal converter
max. 30 m
Signal amplifier
no. 1
Signal amplifiermax. 125
max. 125
max. 125
max. 1,000 m at 0.8 mm2
max
. 1,0
00 m
at 0
.8 m
m2
Emergency luminaires with order suffix .04
Type
of b
us li
ne: e
.g. J
-Y(S
t)Y 2
x2x0
.8
Type of bus line: e.g. J-Y(St)Y 2 x 2 x 0.8up to 125 luminaires
- Interference-free communication provided by signal amplifier; communication line length: max. 2 x 1,000 m
- Simple installation of communication line: T-shaped, star-shaped, linear or even mixed structure. No need to respect polarity.
- Emergency lighting function disabled outside of normal operating hours
- Remote control of MultiDigit® systems via modem or MWEB
- Ongoing records of all system malfunctions
- Automatic generation of detailed system test log
- Execution of all mandatory emergency lighting system controls at minimum costs
- Password protection for system data changes
No. of lumi-naires
per line
Max. line length
Min. cross-section
of bus line
Cable type, e.g.:
40 1,000 m 0.5 mm2 J-Y(St) Y 2 x 2 x 0.8 mm (one core)
80 1,000 m 1.0 mm2 J-Y(St) Y 2 x 2 x 0.8 mm (two cores)
125 1,000 m 1.5 mm2 J-Y(St) Y 4 x 2 x 0.8 mm (three cores)
15
EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS
Tender texts available upon request | Specifications subject to alteration
System description
The MultiDigit® system allows for continuous central control of self-contained emergency luminaires, which report their momentary states to a PC, which evaluates and controls the entire system. An immediate and clear overview of the entire system can thus be provided and used for determining the operational readiness of the emergency lighting system.
Ease of use is ensured by the user-friendly software WINLink, which runs under any current Windows operating system.
The system is very easy to set up. 125 signal amplifiers (grouped and with 125 self-contained emergency luminaires each) can be installed according to the general circuit diagram indicated on page 14. The signal amplifiers ensure interference-free communication over transmission lengths of up to 2,000 meters throughout the entire system.
The communication line does not need to comply with any particular requirements; its structure can be T-shaped, star-shaped, linear or even mixed. Bus line polarity needs not to be considered. one fully-installed system can monitor 15,625 luminaires.
Planning and installation
The address of the emergency luminairs’ signal amplifiers is stored in a microcontroller and therefore needs to be indicated when ordering the system. It can be reprogrammed during the system setup.
System setup and training of the operating personnel by an RZB technician is available upon request and charge.
for information concerning technical issues and planning assistance, please contact your sales representative.
MultiDigit®
H
B
L
16
EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS
Tender texts available upon request | Specifications subject to alteration
MultiDigit®
Starter setType of protection: IP 20 Protection Class: I
for connecting a maximum of 125 RZB luminaires with feedback function (.04), consisting of signal amplifier, signal converter, software and 5 m connecting cable to serial interface of PC (SUB-D9).
Type of installation: DIN profile track
Starter set 671315.000 L 155, B 75, h 120
Signal amplifierfor connecting a further 125 RZB luminaires with incorporated feedback (.04)
Signal amplifier 671148.000 L 155, B 75, h 120
MWEB monitoring modulefor connection to signal amplifier via enclosed interface cable.
The MWEB monitoring module forms the interface between the bus system of the MultiDigit® system and an on-site Ethernet network. MWEB performs the entire control and error management of the emergency lighting system. The system does not require its own PC.
The MWEB module can be accessed via web navigator from any PC in the network that is connected to intranet/internet, without the need for any special software.
for this purpose, the data stored in MWEB are transmitted to the navigator via TCP/IP protocol.
Any malfunction within the system will be immediately displayed in the navigator window; the incorporated e-mail function allows detailed information on the malfunction to be sent to the system administrator. The system can also be accessed via internet if the network is configured accordingly.
MWEB monitoring module 671611.000 L 158, B 90, h 58
H
B
L
H
B
L
17
Webbrowser
(1) (1) (1)
(4) (4) (4)
(5) (6)(7)
(2)
Sig na lverstä rkerM-B US 28V DCL N
Art.Nr.: 671149.000
blink. = Kom munikation
Art.Nr.: 671148.000
8 7 6 5 4 3 2 1
M-BUS28V DC
Spez. Allg.
NotlichtbausteineM-BUS 28 V DC
Hauptleitung
L N
SN 104
Art.Nr.: 671148.000
8 7 6 5 4 3 2 1
M-BUS28V DC
Spez. Allg.
NotlichtbausteineM-BUS 28 V DC
Hauptleitung
L N
SN 27
Art.Nr.: 671148.000
8 7 6 5 4 3 2 1
M-BUS28V DC
Spez. Allg.
NotlichtbausteineM-BUS 28 V DC
Hauptleitung
L N
SN 07
Sig na lverstä rkerM-B US 28V DCL N
Überwachungsmodul für MultiDigit Notbeleuchtungssysteme
MWEBArt.Nr.: 671611.000
RS232nur für Wartung
SystemLAN
Ethernetzu
Signalwandler
IP . . .
654321
NLPE
654321
NLPE
654321
NLPE
654321
NLPE
654321
NLPE
654321
NLPE
654321
NLPE
654321
NLPE
654321
NLPE
654321
NLPE
654321
NLPE
EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS
Tender texts available upon request | Specifications subject to alteration
Monitoring via MWEBPlease note:
All modules and luminaires for MultiDigit® must have order suffix (Y) .04
Max
. 125
lum
inai
res
/ M
ax. l
ine
leng
th: 1
,000
m
Max. 125 signal amplifier / Max. line length: 1,000 m
MultiDigit® module 1
MultiDigit® signal amplifier-M2
MultiDigit® signal amplifier-M2
MultiDigit® signal amplifier-M2
MultiDigit® signal amplifier-M2
MultiDigit® module 1MultiDigit® module 1
MultiDigit® module 2MultiDigit® module 2MultiDigit® module 2
MultiDigit® module 3MultiDigit® module 3
MultiDigit® module 4 MultiDigit® module 125
MultiDigit® module 125
(1) Communication line(2) Main line(3) Multidigit emergency luminaires
RS 232 direct line max. 10 m
RS 232 / max. 10 mMeter BUS 28 V DC
Meter BUS 28 V DC Meter BUS 28 V DC Meter BUS 28 V DC
Ethernet Switch
(4) Signal amplifier (K box)(5) Signal converter (K vert)(6) MWEB (optional)(7) PC with web browser
18
EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS
MWEBplus
System benefits
Continuous central local monitoring of all emergency luminaires (PC for system control is not required).
- Automatic system configuration
- Plain-text reports of all malfunctions, with indication of failure location
- Coordination of self-test activation of all self- contained emergency luminaires
- Error message logs (PC and/or printer)
- Detailed information and control options for each single emergency luminaire
- Tap for forwarding collective/group errors
- Max. 125 luminaires
- Failures will be communicated automatically via e-mail to individually assignable addresses
Monitoring systems
- Interference-free communication provided by signal amplifier; communication line length: max. 1,000 m
- Simple installation of communication line: T-shaped, star-shaped, linear or even mixed structure. No need to respect polarity.
- Emergency lighting function disabled outside of normal operating hours
- Ongoing records of all system malfunctions
- Automatic generation of detailed system test log
- Execution of all mandatory emergency lighting system controls at minimum costs
- Password protection for system data changes
- No need to respect bus line polarity
general circuit diagram for the MWEBplus monitoring system
* The minimum cross-section of the bus line depends on the actual length of the bus line and the number of connected luminaires.
No. 1 No. 2 No. 3 No. 4MWEBplus
max. 125
max. 1,000 m at 0.8 mm2
Emergency luminaires with order suffix .04
Bus line type: e. g. J-Y(St)Y 2 x 2 x 0.8
No. of lumi-naires
per line
Max. line length
Min. cross-section
of bus line
Cable type, e.g.:
40 1,000 m 0.5 mm2 J-Y(St) Y 2 x 2 x 0.8 mm (one core)
80 1,000 m 1.0 mm2 J-Y(St) Y 2 x 2 x 0.8 mm (two cores)
125 1,000 m 1.5 mm2 J-Y(St) Y 4 x 2 x 0.8 mm (three cores)
19
EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS
Tender texts available upon request | Specifications subject to alteration
System description
The MWEBplus system allows for continuous central control of self-contained emergency luminaires, which report their momentary states to a PC, which evaluates and controls the entire system. An immediate and clear overview of the entire system can thus be provided and be used for determining the operational readiness of the emergency lighting system.
The system is very easy to set up. 125 self-contained emergency luminaires can be installed according to the general circuit diagram indicated on page 18.
The communication line does not need to comply with any particular requirements; its structure can be T-shaped, star-shaped, linear or even mixed.
MWEBplus constitutes the interface between the system’s oS and an on-site Ethernet network. Since MWEBplus performs the entire control and error management of the emergency lighting system, a separate PC for the monitoring system is not required.
The MWEBplus module can be accessed via web navigator from any PC in the network that is connected to intranet/internet, without the need for any special software.
for this purpose, the data stored in MWEBplus are transmitted to the navigator via TCP/IP protocol.
Any malfunction within the system will be immediately displayed; the incorporated e-mail function allows detailed information on the malfunction to be sent to the system administrator. The system can also be accessed via internet if the network is configured accordingly.
Monitoring module MWEBplus 671823.000 L 160, B 110, h 63
MWEBplus
H
B
L
20
EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS
Tender texts available upon request | Specifications subject to alteration
Monitoring via MWEBplus
Please note:
All modules and luminaires for MWEBplus must have order suffix (Y) .04
general mains power supply
L
N
MWEBplus
max. 125 luminairesmax. 1,000 m
Bus
general mains power supply
L
N
general mains power supply
L
N
21
654321
NLPE
654321
NLPE
654321
NLPE
654321
NLPE
654321
NLPE
EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS
Tender texts available upon request | Specifications subject to alteration
Monitoring via MWEBplus
Ethernet Switch
Mains 230 V
Max. 125 luminaires Max. length: 1,000 m
Meter-BUS 30 V DC 2 x 1.5 mm2
MultiDigit® module 125
MultiDigit® module 1
MultiDigit® module 2
MultiDigit® module 3
MultiDigit® module 4
22
EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS
System benefits
- Central monitoring of the entire system
- Simple and clear structure
- Automatic function tests
- Simple test log generation
- Easy to install
- Execution of all mandatory tests at minimum costs
- Collective error display on the monitoring unit
- Blinking codes on each luminaire indicate the type of error
Monitoring systems
PZ 50 for 50 self-contained luminaires
Self-test module or lumi-naire / ballast with order suffix .03
Up
to 5
0 em
erge
ncy
light
s!M
ax. l
engt
h of
bus
line
: 40
0 m
(tot
al le
ngth
of l
oop
wiri
ng s
yste
m!)
Type
of b
us li
ne: e
.g. J
-Y(S
t)Y 2
x2x0
.8
200 V ac BUSLoop wiring system
200 V / 50 Hz
PZ 50 monitoring systemcontinuous control of max. 50 emergency luminaires
Please note:
All modules and luminaires for PZ 50 must have order suffix (Y) .03
23
EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS
Tender texts available upon request | Specifications subject to alteration
PZ 50Description
The feedback unit PZ 50 allows for central monitoring of self-test emergency luminaires (.03). The monitoring unit displays any error of any connected emergency luminaire as well as any BUS line disconnection. Moreover, it displays whether the power supply is on or off. It can, however, not be seen which of the luminaires is involved in the failure.
Up to 50 luminaires can be connected to one control unit via a loop wiring system.
Suitable cable type for this system is for example cable J-Y(ST)-Y 2 x 2 x 0.8. Attention: bus line voltage may reach up to 200 V. The maximum line length amounts to 400 meters, which means that the farest distance between any luminaire and the control unit may be max. 200 meters. The BUS line must not be conducted thorough the same cable through which the power supply line is conducted.
Functioning
Automatic luminaire self-test
The emergency luminaires are fitted with additional automatic self-test electronics for testing the luminaire itself, the battery and the lamp of the luminaire, following an optimized testing programme defined for these luminaires. The testing result will be transformed into a visual and audible alarm.
Benefits of autonomous self-test electronics:
- high reliability- Low maintenance- Ease of use- Time saving testing and controlling process
Any malfunction within the system will be displayed on the unit as a collective malfunction, which can be forwarded to any superior system via a potential-free contact (230 V AC/5 A or 24 V/5 A).
Monitoring system for RZB self-contained emergency luminaires with order suffix .03
Type of protection: IP 20
Protection class: I
Power supply: 230 V / 50/60 hz
Power supply (bus line): 200 V
Alarm delay: 10 seconds
Dimensions: L 158, h 90, T 58
Type of installation: DIN profile track
Max. bus line length: 400 m
Max. no. of luminaires that can be monitored: 50 luminaires
Potential-free contact: 230 V AC / 5 A 24 V DC / 5 A
Monitoring system PZ 50671466.009 L 158, h 90, T 58
H
B
L
24
25
Self-contained emergency luminairesTenuo 26LED Halyxx® 28GSUN® S 32Ilustris 34Display 36Flat Sign Mini/Midi 38Design 40Rechteck 250 / 360 / 485 44Multivariabel 50Signcube 52GSUN® 2 55 GSUN® 2 LED 55GSUN® 3 56GSUN® 3 LED 57GSUN® 4 58GSUN® 4 LED 59LCS1 60LCS3 60Varioplast I 62Space 64Universum 66Turia 68Edo 70Lucio 72Centryxx 74Energo TC 175 76Energo TC 210 78Andho TC 80Andho TC IP 65 82Arelo® 84Mondana 86Flat Polymero® 88Flat Polymero® PC with collar 90Flat Basic 92Flat Basic with collar 94Flat Polymero® Rechteck 96Basic 98Kreis 100Rondo 102Rounded® Maxi 104Alu‑Rund 106Weatherproof battens 108Hand‑held LED safety spotlight 110Safety stand spotlight 110
28, 30 - 31 28, 30 - 31 32
44, 47 50 52
38 40 - 4340 - 43
74
54, 56 - 57 54, 58 - 59 54, 58 - 59
76 - 79
94
96
106
64 6866
44, 45
26 28 - 29
44, 46
6054, 55
70
72
62
88
102
110
90
104
92
100
110
98
108
80 - 83 84
86
3634
LED LED LED LED LED
LED
LED LED LED
LEDLED LED
LED LED
LED
LED
LED
LED
8h 8h 8h
8h
8h 8h 8h
26
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
Tenuo Type of protection: IP 40
- The flattest existing emergency luminaire that incorporates the very latest energy saving LED technology
- Ultraflat - (panel 5 mm) frame 8 mm
- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
- Top quality LED technology
- Specially calculated thermal management
- The very latest LED technology keeps maintenance costs to a minimum
- LED service life: approx. 50,000 hours
- Exceptionally high luminance of over 900 cd/m2
- Wide range of applications thanks to various types of installation
Wall extension Wall (semi‑recessed) Ceiling (surface) Ceiling (recessed) Pendant tubeSuspension cable/chain
1003
1113
1114
1004
1115
1116
1005
27
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Wall (surface) Wall extension Wall (semi‑recessed) Ceiling (surface) Ceiling (recessed) Pendant tubeSuspension cable/chain
Installation scheme available on request
Installation scheme available on request
Installation scheme available on request
Installation scheme available on request
Installation scheme available on request
Installation scheme available on request
Installation scheme available on request
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671944.00X.y Wall (surface) 30 m ‑ 1 x LED 2,5 W ‑ ‑ • 3 h L 350, B 33, H 200
671945.00X.y Wall extension 30 m ‑ 1 x LED 5 W ‑ ‑ • 3 h L 400, B 60, H 200
671943.00X.y Wall (semi‑recessed) 30 m ‑ 1 x LED 2,5 W ‑ ‑ • 3 h L 350, B 11, H 200,
LA 173, BA 173, TE 70
671946.00X.y Ceiling (surface) 30 m ‑ 1 x LED 5 W ‑ ‑ • 3 h L 350, B 50, H 240
671947.00X.y Ceiling (recessed) 30 m ‑ 1 x LED 5 W ‑ ‑ • 3 h L 420, B 40, H 252, LA 400, BA 40, HE 90
671948.00X.y Pendant tube 30 m ‑ 1 x LED 5 W ‑ ‑ • 3 h L 350, B 50, H 200, LP 500
671949.00X.y Suspension cable/chain 30 m ‑ 1 x LED 5 W ‑ ‑ • 3 h L 350, B 50, H 200,
LP 500
Series: Tenuo
Type of protection: IP 40 Protection class: I Viewing distance: 30 m
For escape route identification
Housing: aluminium, silver. Display panel with patented MicroLens technology.
LED included.
Please indicate symbol number when placing your order!
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 4 = aluminium, anodised
30 m
H
L B
H
L B
HA
L TE
H
LA
B
H
L B
H
L
LAB
BA
HE
LP
L B
H
LP
L B
H
28
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Wall (surface) Ceiling (surface) Ceiling (recessed) Wall (recessed)
8hfor
accomodation facilities, nursing homes and
multi-storey buildings
(only in Germany)
Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
LED Halyxx® Type of protection: IP 40
- High quality aluminium housing
- High quality and elegant design
- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
- Specially calculated thermal management
- The very latest LED technology keeps maintenance costs to a minimum
- LED service life: approx. 50,000 hours
- Luminance exceeds 500 cd/m2
- Wide range of applications thanks to various types of installation
- Moulded housing for concrete available
- Easy to install
1003
1113
1114
1004
1115
1116
1005
29
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Wall (surface) Ceiling (surface) Ceiling (recessed) Wall (recessed) (cavity wall) Wall (recessed) (solid wall)
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671501.00X.y Wall (surface) 14 m ‑ 4 x LED 1 W • • • 3 h L 233, B 40, H 180
671502.00X.y Ceiling (surface) 14 m ‑ 4 x LED 1 W • • • 3 h L 233, B 40, H 180
671518.00X.y Ceiling (recessed) 14 m ‑ 4 x LED 1 W • • • 3 h L 270, B 55, H 100
LA 255 x BA 42, HE 90
671546.12X.y Wall (recessed) (cavity wall) 14 m ‑ 1 x LED 4 W • • – 3 h L 220, B 2, H 150
LA 210 x BA 132, HE 90
671546.00X.y Wall (recessed) (solid wall) 14 m ‑ 1 x LED 4 W • • – 3 h L 220, B 2, H 150
LA 200 x BA 130, HE 80
Series: LED Halyxx®
Type of protection: IP 40 Protection class: I Viewing distance: 14 m Ceiling thickness: 5‑35 mm Wall thickness: 1‑30 mm
For escape route identification
Base: aluminium extrusion profile; display panel: highly transparent panel with motifs on one side/both sides.
LED included.
Please specify legend number when ordering!
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colours (X): 2 = white (only Wall (recessed)) 4 = aluminium, anodised (all variants)
Mounting set for suspension cable/chainViewing distance: 14 m981701.004 L 213, B 33, H 77 for art. 671502.004.y
Moulded housingViewing distance: 14 m981685.000 L 542, B 142, H 143 for art. 671518.004.y
Accessories | Pendant set for ceiling luminairesPendant length 500 mm (other lengths upon request), white plastic canopy, chrome suspension tube, length: 480 mm, can be shortened on site.
Pendant setsViewing distance: 14 m981639.010 for art. 671502.004981639.030 for art. 671502.004.03981639.040 for art. 671502.004.04/.07
Wall extensionViewing distance: 14 m981581.004 L 258, B 38, H 104 for art. 671502.004.y
14 m
H
L B
H
L B
H
LLA
BBA
HE5-
35
3
180
151233
4523Ø4,5
15
15
150233
Ø5
12,550
1640
4255
255270
HA
LHE
1-30
H
LA
BL
HA
HE
LA
B
H
132150
210220
130150
200220
30
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Series: LED Halyxx®
Type of protection: IP 40 Protection class: I Viewing distance: 19 m Ceiling thickness: 5‑35 mm
For escape route identification
Base: aluminium extrusion profile; display panel: highly transparent panel with motifs on one side/both sides.
LED included.
Please specify legend number when ordering!
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 4 = aluminium, anodised
Wall (surface) Ceiling (surface) Ceiling (recessed)
Mounting set for suspension cable/chainViewing distance: 19 m981701.004 L 213, B 33, H 77 for art. 671742.004.y
Moulded housingViewing distance: 19 m981686.000 L 542, B 142, H 143 for art. 671750.004.y
Accessories | Pendant set for ceiling luminairesPendant length 500 mm (other lengths upon request), white plastic canopy, chrome pendant tube, length: 480 mm, can be shortened on site.
Pendant setsViewing distance: 19 m981639.010 for art. 671742.004981639.030 for art. 671742.004.03981639.040 for art. 671742.004.04/.07
Wall extensionViewing distance: 19 m981581.004 L 258, B 38, H 104 for art. 671742.004.y
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671746.00X.y Wall (surface) 19 m ‑ 4 x LED 1 W • • • 3 h L 235, B 40, H 220
671895.00X.y Wall (surface) 19 m ‑ 4 x LED 1 W • • ‑ 8 h L 235, B 40, H 220
671742.00X.y Ceiling (surface) 19 m ‑ 4 x LED 1 W • • • 3 h L 235, B 40, H 220
671896.00X.y Ceiling (surface) 19 m ‑ 4 x LED 1 W • • ‑ 8 h L 235, B 40, H 220
671750.00X.y Ceiling (recessed) 19 m ‑ 4 x LED 1 W • • • 3 h L 320, B 55, H 140 LA 305 x BA 42, HE 90
671897.00X.y Ceiling (recessed) 19 m ‑ 4 x LED 1 W • • ‑ 8 h L 320, B 55, H 140 LA 305 x BA 42, HE 90
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
19 m
H
L B
H
L B
H
L LA
B BA
HE
5-35
3
220
151235
4523
Ø4,5
15
15
150
233Ø5
12,5
50
1640
4255
305320
31
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Series: LED Halyxx®
Type of protection: IP 40 Protection class: I Viewing distance: 30 m Ceiling thickness: 5‑35 mm
For escape route identification
Base: aluminium extrusion profile; display panel: highly transparent panel with motifs on one side/both sides.
LED included.
Please specify legend number when ordering!
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 4 = aluminium, anodised
Wall (surface) Ceiling (surface) Ceiling (recessed)
Mounting kit for chains/cable suspensionsViewing distance: 30 m981702.004 L 318, B 33, H 57 for art. 671744.004.y
Moulded housingViewing distance: 30 m981687.000 L 542, B 142, H 143 for art. 671752.004.y
Accessories | Pendant set for ceiling luminairesPendant length 500 mm (other lengths upon request), white plastic canopy, chrome pendant tube, length: 480 mm, can be shortened on site.
Pendant setsViewing distance: 30 m981647.010 for art. 671744.004981647.030 for art. 671744.004.03981647.040 for art. 671744.004.04/.07
Wall extensionViewing distance: 30 m981640.000 L 363, B 38, H 104 for art. 671744.004.y
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671748.00X.y Wall (surface) 30 m ‑ 4 x LED 1 W • • • 3 h L 340, B 40, H 270
671912.00X.y Wall (surface) 30 m ‑ 4 x LED 1 W • • ‑ 8 h L 340, B 40, H 270
671744.00X.y Ceiling (surface) 30 m ‑ 4 x LED 1 W • • • 3 h L 340, B 40, H 270
671913.00X.y Ceiling (surface) 30 m ‑ 4 x LED 1 W • • ‑ 8 h L 340, B 40, H 270
671752.00X.y Ceiling (recessed) 30 m ‑ 4 x LED 1 W • • • 3 h L 424, B 55, H 190 LA 410 x BA 42, HE 90
671914.00X.y Ceiling (recessed) 30 m ‑ 4 x LED 1 W • • ‑ 8 h L 424, B 55, H 190 LA 410 x BA 42, HE 90
30 m
H
L B
H
L B
H
L LA
B BA
HE
5-35
3
270
250340
4523
Ø4,5
15
25
40
270340
25
Ø510,5
27,5
4255
410424
32
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface)Wall (surface)
GSUN® S Type of protection: IP 20
- Housing made of top quality aluminium
- Energy efficient (consumption approx. 80% less than 13 W fluorescent lamp technology)
- The very latest LED technology keeps maintenance costs to a minimum
- LED service life: approx. 50,000 hours
- Standard automatic self-test
- Set of 3 easily attachable pictograms
- Easy to install
- Suitable for mounting on either a ceiling or a wall by simply changing the end caps
90°
90°
33
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface)Wall (surface)
Pendant tube981777.014 Pendant lenght 500 mm
Wall extension981779.004 L 260, B 45, H 110
Suspension cable/chain981780.000 Pendant lenght 1500 mm
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671915.00X.y Wall (surface), Ceiling (surface) 24 m ‑ 1 x LED 1 W with automatic self‑test function,
without feedback 3 h L 240, B 45, H 190
Series: GSUN® S
Type of protection: IP 20 Protection class: I Viewing distance: 24 m
For escape route identification
Housing: extruded aluminium profile, with universal installation set for ceiling and wall surface mounting. 3 foils with escape route motif and 1 white foil included for attachment. Automatic self test in all standard versions.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
LED included.
Ballast mains/emergency: EB
Available colour (X): 4 = silver coloured
24 m
H
L B
15
H
L B
15
175
240200
5,5x10
22,5
45
200
5,5x10
34
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Wall (surface) Ceiling (surface)
Ilustris Type of protection: IP 20
- Design matches modern architectural styles
- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
- The very latest LED technology keeps maintenance costs to a minimum
- LED service life: approx. 50,000 hours
- Large viewing distance
- Standard automatic self-test
- Wide range of applications thanks to various types of installation
35
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Wall (surface) Ceiling (surface)
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671842.00X.y Wall (surface) 30 m ‑ 1 x LED 3 W with automatic self‑test function, without feedback
3 h L 368, B 55, H 253
671846.00X.y Ceiling (surface) 30 m ‑ 1 x LED 3 W 3 h L 368, B 27, H 263
Pendant tube981777.0031 Pendant lenght 500 mm
Suspension cable/chain981776.000 Pendant lenght 1500 mm –
Wall extension981775.0031 L 300, B 150, H 35 –
Series: Ilustris
Type of protection: IP 20 Protection class: I Viewing distance: 30 m
For escape route identification
Housing: die‑cast aluminium, powder‑coated. 3 foils with escape route motif and 1 white foil included. Automatic self test in all standard versions.
LED included.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 31 = anthracite metallic
30 m
H
L B
H
L B
Ø5,5
120
150
368
253
35 5522
5,5x10
100368
26
36
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface)Wall (surface) Ceiling (recessed)
Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
Display Type of protection: IP 40
- Absolutely uniform illumination of the motifs
- Wide range of applications thanks to various types of installation
- Designed for large viewing distances
- Standard fluorescent lamps can be used
- Specifically calculated reflector inside the luminaire
1003
1113
1114
1004
1115
1116
1005
37
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface)Wall (surface) Ceiling (recessed)
Accessories | Wall extensionSteel bracket, white powder‑coated
Wall extension981489.002
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671005.75X.y Wall (surface) 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 332, B 70, H 236
671001.75X.y Ceiling (surface) 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 332, B 57, H 305
671003.75X.y Ceiling (recessed) 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 400, B 80, H 180
LA 380 x BA 68, HE 165
Series: Display
Type of protection: IP 40 Protection class: I Viewing distance: 32 m
For escape route identification
Base: metal, powder‑coated. Display panel: plastic, with motifs on one side/on both sides.
Lamp included.
Please specify legend number when ordering!
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colours (X): 2 = white, 4 = silver metallic
Accessories | Pendant setSuspension tube, square: 40 x 40 mm, powder‑coated, suspension length 500 mm (other lengths available upon request)
Pendant set90‑3757.002 Pendant length 500 mm white90‑3757.004 Pendant length 500 mm silver metallic
Moulded housing98186.000
32 m
H
L B
H
L B
H
HE1-40
L
LA BA
B
5716
9618
332276
5x8
125236
5160
332
248
5x8 84
400
68
380
38
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Pendant tubeWall (surface)
Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
Flat Sign Mini/Midi Type of protection: IP 43
- Exclusive luminaire design
- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
- Top quality LED technology
- Uniform light distribution provided by special LED arrangement
- 2 different housing dimensions for different viewing distances
1003
1113
1114
1004
1115
1116
1005
39
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Pendant tubeWall (surface) Mini Wall (surface) Midi
Article number Type of installation
Viewing distance
Type Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671558.00X.y Wall (surface) 21 m Mini 4 x LED 0,5 W • • ‑ 3 h L 237, B 84, H 125
671559.00X.y Wall (surface) 32 m Midi 4 x LED 0,5 W • • ‑ 3 h L 348, B 84, H 178
671560.00X.y Pendant tube 21 m Mini 4 x LED 1 W • • ‑ 3 h L 237, B 138, H 125, LP 480
671615.00X.y Pendant tube 32 m Midi 6 x LED 1 W • • ‑ 3 h L 348, B 138, H 178, LP 480
Series: Flat Sign Mini/Midi
Type of protection: IP 43 Protection class: I Viewing distance: 21 m, 32 m
For escape route identification
Housing: sheet steel, powder‑coated; display panel: plastic, opal, with motifs on one side/on both sides.
LED included.
Please specify legend number when ordering!
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 2 = white
21 m/32 m
LP
L B
H
H
L B
H
L B
60
10
Ø10
Ø3,530
120
27
237
Ø20
9x5125
8
237
27
348
Ø20
9x5178
40
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Pendant tubeCeiling (surface)Ceiling (surface), Wall (surface)
Wall (surface) Wall extension
8hfor
accomodation facilities, nursing homes and
multi-storey buildings
(only in Germany)
Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
Design Type of protection: IP 40
- Flat aluminium housing in elegant design
- Installation-friendly design enables lamp replacement without tools
- Designed for large viewing distances
- Wide range of applications thanks to various types of installation
- Luminaire also available for escape route illumination
1003
1113
1114
1004
1115
1116
1005
41
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Wall (surface) Wall extension Pendant tubeCeiling (surface)
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671590.75X.y Wall (surface) 26 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 294, B 55, H 190
671594.75X.y Wall extension 26 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 314, B 55, H 190
671592.75X.y Ceiling (surface) 26 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 340, B 55, H 232
671596.75X.y Pendant tube 26 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 340, B 55, H 190, LP 524
Series: Design
Type of protection: IP 40 Protection class: I Viewing distance: 26 m
For escape route identification
Housing: aluminium, powder‑coated. Display panels: plastic, opal, with motifs on one side/on both sides.
Lamp included.
Please specify legend number when ordering!
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 2 = white
Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981167.002 L 380, B 295, H 185
26 m
H
L B
H
B L
LP
H
L B
H190
L B
90
15
210
294
190
27
19075
55
18
5,5x106 6
340
8260
82Ø6
5542
52,5 52,5
340169,5
5x12
42
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Wall (surface) Wall extension Pendant tubeCeiling (surface)
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671017.75X.y Wall (surface) 33 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 370, B 55, H 228
671588.75X.y Wall (surface) 33 m ‑ 1 x T16 (T5) 8 W • • ‑ 8 h L 370, B 55, H 228
671023.75X.y Wall extension 33 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 390, B 55, H 228
671219.75X.y Ceiling (surface) 33 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 416, B 55, H 270
671717.75X.y Ceiling (surface) 33 m ‑ 1 x T16 (T5) 8 W • • ‑ 8 h L 416, B 55, H 270
671311.75X.y Pendant tube 33 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 416, B 55, H 228, LP 500
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Series: Design
Type of protection: IP 40 Protection class: I Viewing distance: 33 m
For escape route identification
Housing: aluminium, powder‑coated. Display panels: plastic, opal, with motifs on one side/on both sides.
Lamp included.
Please specify legend number when ordering!
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 2 = white
Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981168.002 L 540, B 375, H 185
33 m
H
L B
H
B L
LP
H
L B
H228
L B
117 22847
283
28370
6x16
22890
55
5x10
18
6 6416
8260
82Ø6
5542
53 53
416208
5x12
43
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Wall (surface), Ceiling (surface) 8 W Wall (surface), Ceiling (surface) 18 W Wall (surface), Ceiling (surface) 36 W Wall (surface), Ceiling (surface) 58 W
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
Spacing table 671586.752
Lamp luminous flux:
Mains: 1350 lm, Emergency: 540 lm
The following values are indicated in m
h a b c d
2.5 8.5 3.6 11.2 4.8
3.0 9.0 3.9 12.1 5.1
3.5 9.6 4.1 13.4 5.4
4.0 10.8 4.3 14.3 5.6
Spacing table 671009.752
Lamp luminous flux:
Mains: 450 lm, Emergency: 185 lm
The following values are indicated in m
h a b c d
2.5 7.0 2.7 9.0 3.5
3.0 7.4 2.8 9.4 3.5
3.5 7.6 2.8 9.8 3.5
4.0 7.6 2.6 10.0 3.4
Spacing table 671013.752
Lamp luminous flux:
Mains: 3350 lm, Emergency: 469 lm
The following values are indicated in m
h a b c d
2.5 8.8 3.7 14.0 5.8
3.0 9.4 3.9 12.4 5.0
3.5 10.1 4.0 13.2 5.3
4.0 10.9 4.2 14.0 5.4
Spacing table 671011.752
Lamp luminous flux:
Mains: 1350 lm, Emergency: 243 lm
The following values are indicated in m
h a b c d
2.5 7.3 2.9 9.6 3.8
3.0 7.8 3.0 10.1 3.9
3.5 8.2 3.1 10.6 4.0
4.0 8.4 3.0 11.0 4.0
Spacing table 671447.752
Lamp luminous flux:
Mains: 5200 lm, Emergency: 416 lm
The following values are indicated in m
h a b c d
2.5 8.6 3.5 11.2 4.6
3.0 9.2 3.7 12.0 4.8
3.5 9.7 3.9 12.8 5.1
4.0 10.4 4.0 13.4 5.2
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671009.75X.y Ceiling (surface), Wall (surface) ‑ 41 % 1 x T16 (T5) 8 W • • ‑ 3 h L 370, B 228, H 55
671011.75X.y Ceiling (surface), Wall (surface) ‑ 20 % 1 x T26 (T8) 18 W • • ‑ 3 h L 695, B 228, H 55
671586.75X.y Ceiling (surface), Wall (surface) ‑ 40 % 1 x T26 (T8) 18 W • • ‑ 8 h L 695, B 228, H 55
671013.75X.y Ceiling (surface), Wall (surface) ‑ 13 % 1 x T26 (T8) 36 W • • ‑ 3 h L 1305, B 228, H 55
671447.75X.y Ceiling (surface), Wall (surface) ‑ 8 % 1 x T26 (T8) 58 W • • ‑ 3 h L 1605, B 228, H 55
Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981168.002 L 540, B 375, H 185 for 8 W
Series: Design
Type of protection: IP 40 Protection class: I
For escape route illumination
Housing: aluminium, powder‑coated. Refractor: transparent plastic, prismatic. Reflector: aluminium, highly polished anodised finish, wide beam.
T16 fluorescent lamp included.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: LLB/EB
Available colour (X): 2 = white
L B
H
L B
H
L B
H
L B
H
117 22864
4444
370
6x16
117 22864
317 4444
1305
6x16
117 22864
313 4444
1605
6x16
120 22852
615
35695
6x16
h
d c b
a
44
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface) Suspension cable/chainPendant tubeWall (surface) Wall extension
Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
Rechteck 250 / 360 / 485 Type of protection: IP 44
- High quality aluminium profile housing
- Installation-friendly conctruction facilitates easy lamp replacement
- Wide range of applications thanks to various types of installation
- Quick and easy to install thanks to the use of a quick-action locking mechanism for the lamp and ballast support
- Available also with exceptionally long service life and energy efficient LED technology
- LED conversion sets are available for existing luminaires
- All versions with downward light emission
1003
1113
1114
1004
1115
1116
1005
45
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface)Wall (surface) Pendant tube Suspension cable/chainWall extension
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671045.00X.y Wall (surface) 21 m ‑ 4 x LED 1 W • • ‑ 3 h L 250, B 125, H 140
671045.75X.y Wall (surface) 21 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 250, B 125, H 140
671049.00X.y Wall extension 21 m ‑ 4 x LED 1 W • • ‑ 3 h L 250, B 125, H 140
671049.75X.y Wall extension 21 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 250, B 125, H 140
671053.00X.y Ceiling (surface) 21 m ‑ 4 x LED 1 W • • ‑ 3 h L 250, B 125, H 140
671053.75X.y Ceiling (surface) 21 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 250, B 125, H 140
671057.00X.y Pendant tube 21 m ‑ 4 x LED 1 W • • ‑ 3 h L 250, B 125, H 140, LP 500
671057.75X.y Pendant tube 21 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 250, B 125, H 140, LP 500
671343.00X.y Suspension cable/chain 21 m ‑ 4 x LED 1 W • • ‑ 3 h L 250, B 125, H 140
671343.75X.y Suspension cable/chain 21 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 250, B 125, H 140
Series: Rechteck 250
Type of protection: IP 44 Protection class: I Viewing distance: 21 m
For escape route identification
Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motifs on one side/on both sides.
Lamp included.
Please specify legend number when ordering!
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colours (X): 2 = white, 4 = aluminium, anodised
Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981167.002 L 380, B 295, H 185
21 m
H
40
BL
40 80
H
L B
LP
H
BL
40 40
40
H
L B
30
80
LB
4080
H
40
3340
140
250
6x1640
40
41
41
18140 80
12580
6x12 5555250
40 1212
80 68 12511
9
Ø 5 6x18 Ø 6
125
70 4x10
85250
60 125
250
50 5030
46
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671061.00X.y Wall (surface) 32 m ‑ 4 x LED 1 W • • ‑ 3 h L 362, B 125, H 192
671061.75X.y Wall (surface) 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 362, B 125, H 192
671065.00X.y Wall extension 32 m ‑ 6 x LED 1 W • • ‑ 3 h L 362, B 125, H 192
671065.75X.y Wall extension 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 362, B 125, H 192
671069.00X.y Ceiling (surface) 32 m ‑ 6 x LED 1 W • • ‑ 3 h L 362, B 125, H 192
671069.75X.y Ceiling (surface) 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 362, B 125, H 192
671073.00X.y Pendant tube 32 m ‑ 6 x LED 1 W • • ‑ 3 h L 362, B 125, H 192, LP 500
671073.75X.y Pendant tube 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 362, B 125, H 192, LP 500
671347.00X.y Suspension cable/chain 32 m ‑ 6 x LED 1 W • • ‑ 3 h L 362, B 125, H 192
671347.75X.y Suspension cable/chain 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 362, B 125, H 192
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Series: Rechteck 360
Type of protection: IP 44 Protection class: I Viewing distance: 32 m
For escape route identification
Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motifs on one side/on both sides.
Lamp included.
Please specify legend number when ordering!
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colours (X): 2 = white, 4 = aluminium, anodised
Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981168.002 L 540, B 375, H 185
Ceiling (surface)Wall (surface) Pendant tube Suspension cable/chainWall extension
32 m
40
3340
192
362
6x1640
40
55
55
192
40
12
12
8068
125119
Ø 5
6x18
Ø 6
5555362
40 1212
80 68 12511
9
Ø 5 6x18 Ø 6
125
70 4x10
85362
60 125
362
50 5030
H
L B
H
40
BL
40 80
LP
H
BL
40 40
40
H
L B
30
40
LB
4080
H
47
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671077.00X.y Wall (surface) 43 m ‑ 4 x LED 1 W • • ‑ 3 h L 485, B 125, H 250
671077.75X.y Wall (surface) 43 m ‑ 1 x T26 (T8) 15 W • • ‑ 3 h L 485, B 125, H 250
671081.00X.y Wall extension 43 m ‑ 6 x LED 1,4 W • • ‑ 3 h L 485, B 125, H 250
671081.75X.y Wall extension 43 m ‑ 1 x T26 (T8) 15 W • • ‑ 3 h L 485, B 125, H 250
671085.00X.y Ceiling (surface) 43 m ‑ 6 x LED 1,4 W • • ‑ 3 h L 485, B 125, H 250
671085.75X.y Ceiling (surface) 43 m ‑ 1 x T26 (T8) 15 W • • ‑ 3 h L 485, B 125, H 250
671089.00X.y Pendant tube 43 m ‑ 6 x LED 1,4 W • • ‑ 3 h L 485, B 125, H 250, LP 500
671089.75X.y Pendant tube 43 m ‑ 1 x T26 (T8) 15 W • • ‑ 3 h L 485, B 125, H 250, LP 500
671351.00X.y Suspension cable/chain 43 m ‑ 6 x LED 1,4 W • • ‑ 3 h L 485, B 125, H 250
671351.75X.y Suspension cable/chain 43 m ‑ 1 x T26 (T8) 15 W • • ‑ 3 h L 485, B 125, H 250
Series: Rechteck 485
Type of protection: IP 44 Protection class: I Viewing distance: 43 m
For escape route identification
Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motifs on one side/on both sides.
Lamp included.
Please specify legend number when ordering!
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colours (X): 2 = white, 4 = aluminium, anodised
Ceiling (surface)Wall (surface) Pendant tube Suspension cable/chainWall extension
43 m
H
40
BL
40 80
40
H
L B
30
LP
H
L B
40 40
H
L B
40
LB
4080
H
5555485
40 1212
80 68 12511
9
Ø 5 6x18 Ø 6
125
485
50 5030
125
4x10
4855050
70 85
60
40
3340
250
485
6x1640
40
55
55
250
40
12
12
8068
125119
Ø 5
6x18
Ø 6
48
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Accessories | Sets for converting luminaires for LED lampsProtection class: I Low‑cost conversion of rectangular luminaires with T16 (or 8 W / 15 W) or common incandescent lamps into luminaires with energy‑efficient, long‑life LEDs. The conversion set can be clicked in any existing housing without needing to use any tool and can be connected to the existing power sup‑ply cable.Modules’ plate: powder‑coated aluminium sheet, ballasts and connecting terminal included. Monitoring function standard.operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Sets for converting luminaires of series „Rechteck 250“ for LED lamps 981724.002 single sided/double sided 4 x LED 1 W/3h981724.002.03 single sided/double sided 4 x LED 1 W/3h981724.002.04 single sided/double sided 4 x LED 1 W/3h
Sets for converting luminaires of series „Rechteck 360“ for LED lamps 981726.002 single sided 4 x LED 1 W/3h981726.002.03 single sided 4 x LED 1 W/3h981726.002.04 single sided 4 x LED 1 W/3h981728.002 double sided 6 x LED 1 W/3h981728.002.03 double sided 6 x LED 1 W/3h981728.002.04 double sided 6 x LED 1 W/3h
Sets for converting luminaires of series „Rechteck 485“ for LED lamps 981773.002 single sided 4 x LED 1 W/3h981773.002.03 single sided 4 x LED 1 W/3h981773.002.04 single sided 4 x LED 1 W/3h981774.002 double sided 6 x LED 1,4 W/3h981774.002.03 double sided 6 x LED 1,4 W/3h981774.002.04 double sided 6 x LED 1,4 W/3h
you can start right now to convert existing emergency luminaires of series Rechteck 250, 360 and 485 from incandescent or fluorescent lamp versions to LED versions.
HOW?
It‘s quite simple and easy: just use our LED conversion kits for self-contained emergency luminaires.
It’s so easy to save money
LED conversion kits
Very easy „press and clip“ mounting. The conversion kit can be inserted in any existing luminaire housing without needing any tool NoR screws:
... press them together and ... ... click them into the luminaire housing.Just take the metal brackets ...
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
49
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
The correct arrangement of the LEDs was calculated by our photometry lab, which allows us to minimize the number of LEDs, without impairing the required luminance values laid down in DIN 4844, Part 1 (luminance of more than 500 cd/m2 for the contrast colour).
Thanks to a clever heat management, we are able to drastically reduce heat stress fort he LEDs, preventing thus an early LED failure.
Average LED service life: approx. 50,000 hours!
Energy efficiency and costs
= costs for power supply
= costs for lamps
= lamp replacement costs
Costs comparison over a period of 5 years
Rechteck 360 in maintained mode (24h/day) LED Fluorescent lamp Incandescent lamp
Lamp wattage 4 W 8 W 2 x 25 W
Service life in hours 50,000 h 3 000 h 1,000 h
Total consumption in 1 year (8,760 h) in kWh 35.04 kWh 70.08 kWh 438.00 kWh
Power supply costs in 1 year (at 0.19 €/kWh) 6.66 € 13.32 € 83.22 €
Total consumption in 5 years (43,800 h) in kWh 175.20 kWh 350.40 kWh 2,190.00 kWh
Power supply costs in 5 years (at 0.19 €/kWh) 33.29 € 66.58 € 416.10 €
Number of lamps needed in 5 years (43,800 h) 0 14 43
Costs for lamps in 5 years 0.00 € 107.10 € 118.68 €
Average time needed for replacing a lamp (minutes) 15 min. 10 min. 10 min.
Costs for replacing lamps (caretaker 25.00 €/h) 0.00 € 58.33 € 179.17 €
Total costs in 5 years (power supply, lamps, lamp replacement) 33.29 € 232.01 € 713.95 €
Incandescent lamps 2 x 25 W713.95 €
LED 4 W
33.29 €
T168 W
232.01 €
50
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface) Pendant tube
Multivariabel Type of protection: IP 54
- Industrial Design
- IP 54 type of protection - dustproof and protected against water spray
- Quick and easy to install thanks to the use of a quick-action locking mechanism for the lamp and ballast support
- Different types of installation for one sole luminaire
- Lamp replacement without tools
- Easy to install
51
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface) Pendant tube
Spacing table 671467.752
Lamp luminous flux:
Mains: 450 lm, Emergency: 144 lm
The following values are indicated in m
h a b c d
2.5 4.8 1.5 6.2 2.0
3.0 4.6 1.1 6.0 1.7
3.5 ‑ ‑ ‑ ‑
4.0 ‑ ‑ ‑ ‑
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671467.75X.y Ceiling (surface), Wall (surface) ‑ 32 % 1 x T16 (T5) 8 W • • ‑ 3 h L 370, B 130, H 130
671368.75X.y Ceiling (surface), Wall (surface) 22 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 370, B 130, H 130
671370.75X.y Pendant tube 22 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 370, B 130, H 130, LP 500
Series: Multivariabel
Type of protection: IP 54 for indoor use Protection class: I Viewing distance: 22 m
For escape route identification or escape route illumination
Base: aluminium, powder‑coated; diffuser: plastic, opal, 3 Foils for escape route identification included.
Lamp included.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 2 = white
Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981168.002 L 540, B 375, H 185
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
Replacement foils991058 Replacement foil (Combi) for 21 m
22 m
H
L B H
LP
L B
130
370
Ø6
40 4030 30
4520
50
80
4x14
h
d c b
a
52
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface) Pendant tube Suspension cable/chain
Special motifs in accordance with BGV A8
Signcube Type of protection: IP 40
- Motifs on four sides
- Plastic cube (PMMA)
- Wide range of applications thanks to various types of installation
- Optimum light distribution
- Suspension can be shortened on site
- Easy to install
53
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface) Pendant tube Suspension cable/chain
Replacement foils991116 Motif foil 240 x 240 Motif 2003991117 Motif foil 240 x 240 Motif 2004991118 Motif foil 240 x 240 Motif 2005
Accessories | Legend foils in accordance with UVV BGV A8 and EECR 92/58Viewing distance 48 m
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671605.92X.y Ceiling (surface), Wall (surface) 24 m ‑ 1 x TC‑DEL 13 W • • ‑ 3 h L 255, B 255, H 276
671606.92X.y Pendant tube 24 m ‑ 1 x TC‑DEL 13 W • • ‑ 3 h L 255, B 255, H 291, LP 510
671614.92X.y Suspension cable/chain 24 m ‑ 1 x TC‑DEL 13 W • • ‑ 3 h L 255, B 255, H 300
Series: Signcube
Type of protection: IP 40 Protection class: I Viewing distance: 24 m
For escape route identification
Base: powder‑coated metal; canopy: plastic, white; pendant tube: metal, chrome (can be shortened on site); diffuser: plastic (PMMA), opal; 3 foils included (according to DIN 4844).
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 2 = white 24 m
B
L
H
LP
L
Ø108
B
H
B
L
H
190
38
190
255
255
27
Ø4,5x9
60
10
Ø10
Ø3,530 110
38
107
255
255
28
2003 2004 2005
54
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Wall (surface) GSUN® 2
Wall (surface) GSUN® 2 LED
Ceiling (surface), Wall (surface) GSUN® 3 / GSUN® 3 LED
Ceiling (surface), Wall (surface) GSUN® 4 / GSUN® 4 LED
Wall (surface) GSUN® 4 / GSUN® 4 LED
GSUN® 2 / GSUN® 2 LED Type of protection: IP 44
- All-plastic luminaire, shockproof
- Installation benefits for protections class II
- 3 escape route motifs included
- Low-cost installation
in addition for GSUN® 2 LED
- Reliable and long life LED technology
- LED service life: approx. 50,000 hours
- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
- Very low current consumption
GSUN® 3 / GSUN® 4 Type of protection: IP 54
- All-plastic luminaire, shockproof
- IP 54 type of protection - dustproof and protected against water spray
- Can be used for all types of installation (with accessories)
- Low current consumption
- 3 escape route motifs included
- Low-cost installation
GSUN® 3 LED / GSUN® 4 LED Schutzart: IP 54
- All-plastic luminaire, shockproof
- IP 54 type of protection - dustproof and protected against water spray
- Can be used for all types of installation (with accessories)
- Reliable and long life LED technology
- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
- LED service life: approx. 50,000 hours
- 3 escape route motifs included
- Low-cost installation
- 8 h version
55
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Wall (surface) Wall (surface)
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
65133 Wall (surface) 19 m ‑ 1 x Co16 5 W + 2 x D11 0.5 W ‑ ‑ ‑ 3 h L 215, B 115, H 110
671817.00X.y Wall (surface) 19 m ‑ LED 0.2 W ‑ ‑ ‑ 3 h L 215, B 115, H 110
Series: GSUN® 2
Type of protection: IP 43 Protection class: II Viewing distance: 19 m
For escape route identification
Base: plastic. Diffuser: plastic, opal. Combination foil with black rescue symbols included. Lamps included (2 x D11 0.5 W and 1 x Co16 5 W).
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Available colour: black
Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981167.002 L 380, B 295, H 185
Series: GSUN® 2 LED
Type of protection: IP 40 Protection class: II Viewing distance: 19 m
For escape route identification
Base: plastic. Diffuser: plastic, opal. Combination foil with escape route motif included.
LED included.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Available colour (X): 9 = grey
19 m
H
B
L
25
25114
85 85
214
6x10
19 m
H
B
L
25
25114
85 85
214
6x10
56
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface) (high hood)
Ceiling (surface), Wall (surface) (flat hood)
Spacing table 671321.752
Lamp luminous flux:
Mains: 300 lm, Emergency: 108 lm
The following values are indicated in m
h a b c d
2.5 3.3 1.1 4.3 0.7
3.0 ‑ ‑ ‑ ‑
3.5 ‑ ‑ ‑ ‑
4.0 ‑ ‑ ‑ ‑
Accessories | Kits for converting luminaires for LED lampsProtection class: ILow‑cost solution for converting existing GSUN® 3 luminaires with T16 6 W (or 8 W / 15 W) into lumi‑naires with energy‑efficient, long‑life LEDs. The conversion kit can be installed in any existing housing and can be connected to the existing power supply cable.operating mode: non‑maintained or maintained.
Kit for converting GSUN® 3 for LED lamps981781.000 1 x LED 2,1 W/3h
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671574.75X.y Wall (surface) 21 m 33 % 1 x T16 (T5) 6 W • • ‑ 3 h L 240, B 126, H 78
671639.75X.y Wall (surface) 21 m 38 % 1 x T16 (T5) 6 W with automatic self‑test function, without feedback 3 h L 240, B 126, H 78
671520.00X.y Ceiling (surface), Wall (surface) 21 m ‑ 1 x Co26 15 W +
2 x D11 0,5 W ‑ ‑ ‑ 3 h L 240, B 126, H 145
671321.75X.y Ceiling (surface), Wall (surface) 21 m 33 % 1 x T16 (T5) 6 W • • ‑ 3 h L 240, B 126, H 145
671618.75X.y Ceiling (surface), Wall (surface) 21 m 38 % 1 x T16 (T5) 6 W with automatic self‑test function,
without feedback 3 h L 240, B 126, H 145
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Series: GSUN® 3
Type of protection: IP 54 for indoor use Protection class: II (I for .04) Viewing distance: 21 m
For escape route identification or escape route illumination
Base: plastic; diffuser: plastic, opal, motif foil included, lamp included, test button incorporated in standard version.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast emergency/mains: EB
Available colour (X): 2 = white
Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981167.002 L 380, B 295, H 185
Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.
Pendant tube90‑4164.002 LP 500 mm
Accessories | Wall extensionSteel, white powder‑coated
Wall extension 981144.002 L 251, B 131, H 60
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
21 m
H
L B
H
L B
13
13100
80 100240
70
126
5x11
13
13100
80 100240
70
126
5x11h
d c b
a
57
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface) (high hood)
Ceiling (surface), Wall (surface) (flat hood)
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671707.00X.y Wall (surface) 21 m ‑ 1 x LED 2,1 W • • ‑ 3 h L 240, B 126, H 78
671908.00X.y Wall (surface) 21 m ‑ 1 x LED 2,1 W ‑ • ‑ 8 h L 240, B 126, H 78
671780.00X.y Ceiling (surface), Wall (surface) 21 m ‑ 1 x LED 2,1 W • • ‑ 3 h L 240, B 126, H 145
671909.00X.y Ceiling (surface), Wall (surface) 21 m ‑ 1 x LED 2,1 W ‑ • ‑ 8 h L 240, B 126, H 145
Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981167.002 L 380, B 295, H 185
Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.
Pendant tube90‑4164.002 LP 500 mm
Accessories | Wall extensionSteel, white powder‑coated
Wall extension981144.002 L 251, B 131, H 60
Series: GSUN® 3 LED
Type of protection: IP 54 for indoor use Protection class: II (I for .04) Viewing distance: 21 m
For escape route identification
Base: plastic. Diffuser: plastic, opal. Combination foil with three rescue symbols included. LED included. Test button integrated in standard version.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 2 = white
H
L B
H
L B
13
13100
80 100240
70
126
5x11
13
13100
80 100240
70
126
5x11
21 m
58
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Kit for converting GSUN® 4 for LED lamps981771.000 1 x LED 4,5 W/3h
Ceiling (surface), Wall (surface) (high hood) opal
Ceiling (surface), Wall (surface) (flat hood) transparent, prismatic
Spacing table 671515.752
Lamp luminous flux:
Mains: 450 lm, Emergency: 157 lm
The following values are indicated in m
h a b c d
2.5 5.7 2.3 7.2 2.6
3.0 6.3 2.3 7.4 2.6
3.5 5.7 2.3 7.0 2.5
4.0 6.5 2.1 7.1 2.1
Spacing table 671517.752
Lamp luminous flux:
Mains: 450 lm, Emergency: 157 lm
The following values are indicated in m
h a b c d
2.5 5.5 1.9 6.9 2.5
3.0 4.9 1.6 6.1 2.3
3.5 4.4 1.1 6.4 1.8
4.0 ‑ ‑ ‑ ‑
Accessories | Kits for converting luminaires for LED lamps
Protection class: ILow‑cost solution for converting existing GSUN® 4 luminaires with T16 6 W (or 8 W / 15 W) into lumi‑naires with energy‑efficient, long‑life LEDs. The conversion kit can be installed in any existing housing and can be connected to the existing power supply cable.operating mode: non‑maintained or maintained.
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
Multi‑Digit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671515.75X.y Ceiling (surface), Wall (surface) 25 m 32 % 1 x T16 (T5) 8 W • • ‑ 3 h L 344, B 144, H 78
671619.75X.y Ceiling (surface), Wall (surface) 25 m 32 % 1 x T16 (T5) 8 W with automatic self‑test function,
without feedback 3 h L 344, B 144, H 78
671517.75X.y Ceiling (surface), Wall (surface) 21 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 344, B 144, H 148
671620.75X.y Ceiling (surface), Wall (surface) 21 m ‑ 1 x T16 (T5) 8 W with automatic self‑test function,
without feedback 3 h L 344, B 144, H 148
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Series: GSUN® 4
Type of protection: IP 54 for indoor use Protection class: II (I for .04) Viewing distance: 21 m, 25 m
For escape route identification or escape route illumination
Base: plastic (polycarbonate); diffuser: plastic (polycarbonate), opal, or refractor: transparent plastic (polycarbonate), prismatic; motif foils included; test button integrated in standard version.
Lamp included.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 2 = white
Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981168.002 L 540, B 375, H 185
Mounting kit for chains/cable suspensions981583.002
Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.
Pendant tube90‑4164.002 LP 500 mm
Accessories | Wall extensionSteel bracket, white powder‑coated
Wall extension981485.002 L 374, B 147, H 75
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
21 m/25 m
H
L B
50
250
15 110148,5
344
112,5 144
5x11
50
250
15 110148,5
344
112,5 144
5x11 h
d c b
a
59
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface) (high hood) opal
Ceiling (surface), Wall (surface) (flat hood) transparent, prismatic
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
Multi‑Digit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671792.00X.y Wall (surface) 25 m ‑ 1 x LED 4,5 W • • ‑ 3 h L 344, B 144, H 78
671906.00X.y Wall (surface) 25 m ‑ 1 x LED 4,5 W • • ‑ 8 h L 344, B 144, H 78
671819.00X.y Ceiling (surface), Wall (surface) 21 m ‑ 1 x LED 4,5 W • • ‑ 3 h L 344, B 144, H 148
671907.00X.y Ceiling (surface), Wall (surface) 21 m ‑ 1 x LED 4,5 W • • ‑ 8 h L 344, B 144, H 148
Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981168.002 L 540, B 375, H 185
Mounting kit for chains/cable suspensions981583.002
Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.
Pendant tube90‑4164.002 LP 500 mm
Accessories | Wall extensionSteel bracket, white powder‑coated
Wall extension981485.002 L 374, B 147, H 75
Series: GSUN® 4 LED
Type of protection: IP 54 for indoor use Protection class: II (I for .04) Viewing distance: 21 m, 25 m
For escape route identification
Base: plastic (polycarbonate); diffuser: plastic (polycarbonate), opal, or refractor: transparent plastic (polycarbonate), prismatic, motif foil included, test button integrated in standard version.
LED included.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 2 = white
50
250
15 110148,5
344
112,5 144
5x11
50
250
15 110148,5
344
112,5 144
5x11
H
L B
H
BL
21 m/25 m
60
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface) Wall (surface)
LCS1 Type of protection: IP 40
- Extremely flat housing
- Reflector inside
- Lamp replacement without tools
- Easy to mount
- Large viewing distance
- Easy to install
61
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface)
Spacing table 671608.752
Lamp luminous flux:
Mains: 400 lm, Emergency: 140 lm
The following values are indicated in m
h a b c d
2.5 5.9 2.2 8.7 3.2
3.0 6.2 2.2 9.0 2.9
3.5 6.4 2.2 9.1 2.6
4.0 6.5 2.1 8.8 2.2
Spacing table 671609.752
Lamp luminous flux:
Mains: 400 lm, Emergency: 140 lm
The following values are indicated in m
h a b c d
2.5 2.7 7.9 6.7 5.5
3.0 2.4 8.0 6.7 5.7
3.5 1.9 7.8 6.5 5.8
4.0 1.7 7.2 6.2 5.8
Replacement foils991112 Set of rescue symbols
2003, 2004 and 2005, viewing distance 35 m
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671608.75X.y Ceiling (surface), Wall (surface) 35 m 36 % 1 x T16 (T5) 8 W ‑ ‑ ‑ 1 h L 398, B 62, H 202
671609.75X.y Ceiling (surface), Wall (surface) 35 m 38 % 1 x T16 (T5) 8 W • • ‑ 3 h L 398, B 62, H 202
Series: LCS1
Type of protection: IP 40 Protection class: II Viewing distance: 35 m
For escape route identification or escape route illumination (escape route identification only for Wall (surface).)
Base and reflector: plastic (polycar‑bonate). Refractor: plastic (PMMA), transparent. Function monitoring and test button: standard. Lamp included.
Please note: Luminaire is only available for opera‑tion in non‑maintained power mode. It cannot be modified.
Motifs sets are to be ordered separately.
Ballast: EB
Available colour (X): 2 = white
Series: LCS3
Type of protection: IP 40 Protection class: II (I for .04) Viewing distance: 35 m
For escape route identification or escape route illumination (escape route identification only for Wall (surface).)
Base and reflector: plastic (polycarbo‑nate). Refractor: plastic (PMMA), trans‑parent. Three foils with escape legends included. Function monitoring and test button integrated in standard version. Lamp included. operating mode: Can either be connec‑ted in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
H
L B
174202
250371
398
8016
18
Ø5
35 m
H
L B
174202
250371
398
8016
18
Ø5
35 m
h
d c b
a
62
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface) Wall (surface)
Varioplast I Type of protection: IP 54
- Ultraflat design
- IP 54 type of protection - dustproof and protected against water spray
- Installation-friendly construction: folding mounting plate with lampholder and ballast
- Shockproof verison
- Compact design
- Multi-purpose applications
63
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface)
Spacing table 671111.75X
Lamp luminous flux:
Mains: 300 lm, Emergency: 108 lm
The following values are indicated in m
h a b c d
2.5 5.3 2.0 6.0 2.2
3.0 5.3 1.9 6.1 2.1
3.5 5.0 1.7 5.7 1.8
4.0 5.3 1.3 4.9 1.4
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671113.75X.y Wall (surface) 24 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 320, B 80, H 186
671111.75X.y Ceiling (surface), Wall (surface) ‑ 33 % 1 x T16 (T5) 6 W • • ‑ 3 h L 320, B 80, H 186
Series: Varioplast I
Type of protection: IP 54 for indoor use Protection class: I Viewing distance: 24 m
For escape route identification (only in case of Wall (recessed)) or escape route illumination
Base: plastic (polycarbonate); refractor: plastic (polycarbonate), transparent, prismatic inside, 3 foils for escape route identification included.
Lamp included.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colours (X): 2 = white, 3 = black
Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981168.002 L 540, B 375, H 185
Accessories | Set of screws with special anti-theft key90‑4013.002 white90‑4013.003 black
Accessories | Wire guard, varnished22125.002 L 314, B 180, H 49 white22125.003 L 314, B 180, H 49 black
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
24 m
H
B
L
6
27148
16
115
288320
15430
116 186
8016
5x8
h
d c b
a
64
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface)
Space Type of protection: IP 40
- Shockproof housing in flat, elegant design
- Installation-friendly construction
- Easy lamp replacement
- Theft protection: quick mount adaptor with lock system
- Reflector inside
- Functional design
65
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface)
Spacing table 67923.750
Lamp luminous flux:
Mains: 450 lm, Emergency: 225 lm
The following values are indicated in m
h a b c d
2.5 6.3 2.3 5.7 2.2
3.0 6.1 2.4 5.8 2.3
3.5 5.6 2.0 5.9 2.3
4.0 5.7 1.7 5.8 1.9
Spacing table 67924.750
Lamp luminous flux:
Mains: 300 lm, Emergency: 150 lm
The following values are indicated in m
h a b c d
2.5 6.2 2.3 5.6 2.1
3.0 6.1 2.1 5.3 2.2
3.5 5.8 2.0 5.7 2.1
4.0 5.2 1.6 6.0 1.7
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
67924.75X.y Ceiling (surface), Wall (surface) 20 m 54 % 1 x T16 (T5) 6 W ‑ ‑ ‑ 3 h L 280, B 130, H 53
67923.75X.y Ceiling (surface), Wall (surface) 25 m 58 % 1 x T16 (T5) 8 W ‑ ‑ ‑ 3 h L 374, B 164, H 70
Series: Space
Type of protection: IP 40 Protection class: II Viewing distance: 20 m, 25 m
For escape route identification (only in case of wall installation) or escape route illumination
Base: plastic, grey. Refractor: plastic (polycarbonate), transparent, prismatic. Patented quick mount adaptor. 3 plastic foils and lamp included.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 9 = grey
Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981167.002 L 380, B 295, H 185 for 6 W981168.002 L 540, B 375, H 185 for 8 W
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
20 m/25 m
L
H
B
L
H
B
40104130
170
254280
65
5x10
4060
134164
170240
344374
65
5x10
h
d c b
a
66
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface)
Universum Type of protection: IP 40
- Shockproof housing in flat, elegant design
- Installation-friendly construction
- Easy lamp replacement
- Theft protection: quick mount adaptor with lock system
- Reflector inside
- Functional design
67
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface)
Spacing table 671116.750
Lamp luminous flux:
Mains: 450 lm, Emergency: 167 lm
The following values are indicated in m
h a b c d
2.5 6.4 2.3 6.0 2.2
3.0 6.6 2.3 6.0 2.3
3.5 6.4 2.0 6.0 2.2
4.0 6.4 1.6 6.2 1.8
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671116.75X.y Ceiling (surface), Wall (surface) 20 m 37 % 1 x T16 (T5) 8 W ‑ ‑ ‑ 3 h L 360, B 115, H 52
Series: Universum
Type of protection: IP 40 Protection class: II Viewing distance: 20 m
For escape route identification or escape route illumination
Base: plastic, white. Refractor: plastic (polycarbonate), transparent, prismatic. Patented quick mount adaptor. 3 foils and lamp included.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 9 = grey
Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981168.002 L 540, B 375, H 185
Accessories | Recessed housing with cover frameRecess dimensions: 410 x 145 mm, depth 52 mmRecessed housing with cover frame67006.009 L 415, B 165, H 44, HE 52
Accessories | Escape route identificationfor surface ceiling mounting or recessed ceiling mounting (recessed ceiling mounting in connection with 67006.009).
Display dimensions: L 310, B 155 mm, viewing distance : 30 m
Accessories | Escape route identification67004.009 Escape route right/left67005.009 Emergency exit
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
20 m
L
H
B
40104115
170
347360
65
5x10
h
d c b
a
68
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (recessed)
Turia Type of protection: IP 30
- Wide luminaire spacing for escape route illumination
- Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology)
- Top quality LED technology
- Specially calculated thermal management
- Very low maintenance costs
- LED service life: approx. 50,000 hours
- Easy to install
- Compact design
- Inconspicuous design
- The single-battery module and storage battery can be inserted and removed through the ceiling opening
69
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (recessed)
Spacing table 671920.00X und 671921.00X
Lamp luminous flux:
Mains: 148 lm, Emergency: 148 lm
The following values are indicated in m
h a b c d
2.5 7.3 3.0 7.3 3.0
3.0 8.2 3.4 8.2 3.4
3.5 8.9 3.6 8.9 3.6
4.0 9.5 3.7 9.5 3.7
Article number Type of installation
operating mode BS / DS
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671920.00X.y Ceiling (recessed) BS 100 % 1 x LED 2 W ‑ ‑ • 3 h D 50, H 2 DA 42, HE 45
671921.00X.y Ceiling (recessed) BS / DS 100 % 1 x LED 2 W ‑ ‑ • 3 h D 50, H 2 DA 42, HE 45
Step 1 Step 2
Step 3 Step 4
Series: Turia
Type of protection: IP 30 Protection class: II Ceiling thickness: 15‑35 mm
For escape route illumination
Housing: die‑cast aluminium. Bezel ring: plastic, white. Module and battery in separate ballast box with connecting cable. Automatic self test in all standard versions.
LED included.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
HDAD
HE
Ø50 Ø42
h
d c b
a
70
+
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Edo 1 Installation in existing luminiares
Edo 2 Installation in metal ceilings
Edo 4 Edo 5
Example
Edo Type of protection: IP 20
- Wide luminaire spacing for escape route illumination
- Energy efficient (consumption approx. 80% less than 13 W fluorescent lamp technology)
- Top quality LED technology
- Specially calculated thermal management
- Very low maintenance costs
- LED service life: approx. 50,000 hours
- Easy to install
- Compact design
- Inconspicuous design
+
=
71
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Edo 1 Edo 2 Edo 4 Edo 5
Accessories | Fixing bracket for Edo 1Bracket for fixing Edo 1 into recessed luminiares such as downlights or louvre luminaires. Bracket is to be installed in existing reflector or louvre.
Fixing bracket for Edo 1981778.000 L 25, B 19, H 22
Spacing table 671931.004
Lamp luminous flux:
Mains: 109 lm, Emergency: 109 lm
The following values are indicated in m
h a b c d
2.5 7.7 3.0 7.7 3.0
3.0 8.5 3.2 8.5 3.2
3.5 8.9 3.2 8.9 3.2
4.0 9.1 3.2 9.1 3.2
Article number Type of installation
operating mode BS / DS
Type Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671931.00X.y Retrofitting kit BS Edo 1 1 x LED 2 W ‑ ‑ • 3 h D 22, H 8, DA 10.5, HE 15
671932.00X.y Retrofitting kit BS / DS Edo 1 1 x LED 2 W ‑ ‑ • 3 h D 22, H 8, DA 10.5, HE 15
671933.00X.y Installation in metal ceilings BS Edo 2 1 x LED 2 W ‑ ‑ • 3 h D 27, H 1, DA 22, HE 23
671934.00X.y Installation in metal ceilings BS / DS Edo 2 1 x LED 2 W ‑ ‑ • 3 h D 27, H 1, DA 22, HE 23
671927.00X.y Ceiling (recessed) BS Edo 4 1 x LED 2 W ‑ ‑ • 3 h D 50, H 3, DA 40, HE 45
671928.00X.y Ceiling (recessed) BS / DS Edo 4 1 x LED 2 W ‑ ‑ • 3 h D 50, H 3, DA 40, HE 45
671929.00X.y Ceiling (recessed) BS Edo 5 1 x LED 2 W ‑ ‑ • 3 h L 50, B 50, H 3, DA 40, HE 45
671930.00X.y Ceiling (recessed) BS / DS Edo 5 1 x LED 2 W ‑ ‑ • 3 h L 50, B 50, H 3, DA 40, HE 45
Table applies to all Edo series luminaires
Series: Edo
Type of protection: IP 30 Protection class: II Ceiling thickness: 1‑8 mm (Edo 1 and Edo 2) Ceiling thickness: 15‑35 mm (Edo 4 and Edo 5)
For escape route illumination
Housing: die‑cast aluminium, bezel ring: plastic, white, (only Edo 4 + 5), separate ballast box with connection cable. Automatic self test in all standard versions.
LED included.
operating mode: Can be ordered either for non‑maintained (BS) or maintained (DS).
Ballast mains/emergency: EB
Luminous flux factor 100%
Available colours (X): 2 = white (Edo 4 and Edo 5), 4 = aluminium (Edo 1 and Edo 2)
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
H
DA
HE
D
DA
D
H
HE
HDAD
HE
HBAB
HE
LA L
Ø50 Ø40 Ø50 Ø40
Edo 2
Edo 1
h
d c b
a
72
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface) Ceiling (recessed)
Lucio Type of protection: IP 40
- Wide luminaire spacing for escape route illumination
- Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology)
- Top quality LED technology
- Specially calculated thermal management
- Very low maintenance costs
- LED service life: approx. 50,000 hours
- Compact design
- Easy to install
- Wide range of applications thanks to either surface or recessed ceiling installation
73
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface) Ceiling (recessed)
Spacing table 671917.002
Lamp luminous flux:
Mains: 82 lm, Emergency: 82 lm
The following values are indicated in m
h a b c d
2.5 5.3 2.1 5.3 2.1
3.0 5.9 2.1 5.9 2.1
3.5 6.3 1.9 6.3 1.9
4.0 6.4 1.5 6.4 1.5
Spacing table 671918.002
Lamp luminous flux:
Mains: 100 lm, Emergency: 100 lm
The following values are indicated in m
h a b c d
2.5 7.1 3.0 4.3 1.6
3.0 8.0 3.3 4.5 1.6
3.5 8.7 3.6 4.6 1.7
4.0 9.3 3.8 4.8 1.7
Article number Type of installation
Type Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671917.00X.y Ceiling (surface), Ceiling (recessed)
without lenses 100% 1 x LED 3 W ‑ ‑ • 3 h Surface installation:
D 120, H 45
Recessed installation: D 120, H 3, DA 105, HE 42
671918.00X.y Ceiling (surface), Ceiling (recessed)
with lenses 100% 1 x LED 3 W ‑ ‑ • 3 h
Series: Lucio
Type of protection: IP 40 Protection class: II Ceiling thickness: 5‑25 mm
For escape route illumination
Housing: plastic. Accessories for recessed and surface mounting on the ceiling are included. Automatic self test in all standard versions.
LED included.
operating mode: non‑maintained power mode (BS)
Ballast: EB
2 lenses included in article number 671918.00X.y.
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
H
D
104
HDAD
HE
51
25(78)
Ø4,2
Ø16
Ø12059
73,5Ø4,2
Ø120 Ø105
h
d c b
a
74
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (recessed), squareCeiling (surface) Ceiling (recessed), round
Centryxx Type of protection: IP 40
- Wide luminaire spacing for escape route illumination
- Design matches modern architectural styles
- Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology)
- Top quality LED technology
- Specially calculated thermal management
- Very low maintenance costs
- LED service life: approx. 50,000 hours
- Easy to install
75
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (recessed), square Ceiling (recessed), roundCeiling (surface)
Spacing table 671840.002
Lamp luminous flux:
Mains: 180 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 3.4 0.9 12.6 5.6
3.0 3.0 0.8 14.2 6.4
3.5 2.6 0.7 16.1 7.1
4.0 2.4 0.0 10.5 0.0
Table applies to all Centryxx series luminaires
Article number Type of installation
Type Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671840.00X.y Ceiling (surface) square 100 % 1 x LED 3 W
with automatic self‑test function, without feedback
3 h L 180, B 180, H 27
671838.00X.y Ceiling (recessed) square 100 % 1 x LED 3 W 3 h L 220, B 220, H 3, DA 185, HE 73
671836.00X.y Ceiling (recessed) round 100 % 1 x LED 3 W 3 h D 200, H 3 DA 185, HE 73
Series: Centryxx
Type of protection: IP 20 (Ceiling (surface)), IP 40 (Ceiling (recessed)) Protection class: I
For escape route illumination
Housing: die‑cast aluminium, powder‑coated; plastic diffuser for ideal light distribution on escape route. Automatic self test in all standard versions.
LED included.
operating mode: non‑maintained power mode (BS)
Ballast mains/emergency: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
HDAL
HE
B
HDAD
HE
B
L H
220 Ø185
220
Ø200 Ø185
Ø5
180
90180
90
51
Ø5
h
d c b
a
76
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (recessed)
Energo TC 175 Type of protection: IP 23
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Housing made of top quality die-cast aluminium
- Wide luminaire spacing for escape route illumination
- Modern design
- Bezel ring made of die-cast aluminium
- Infinitely adjustable spring fastening system
- EBs in separate ballast box
- Modular recessed luminaire with small recessed depth
- Easy to install
- For ceiling thicknesses of 1-40 mm
77
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (recessed)
Moulded housing981656.000 Moulded housing L 500, B 250, H 160 mm
Spacing table 671873.92X und 671875.92X
Lamp luminous flux:
Mains: 900 lm, Emergency: 162 lm
The following values are indicated in m
h a b c d
2.5 7.7 2.8 7.7 2.8
3.0 8.1 2.9 8.1 2.9
3.5 8.4 2.8 8.4 2.8
4.0 8.3 2.7 8.3 2.7
Spacing table 671874.96X und 671876.96X
Lamp luminous flux:
Mains: 1200 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 7.5 2.9 7.5 2.9
3.0 8.1 3.1 8.1 3.1
3.5 8.5 3.0 8.5 3.0
4.0 8.7 3.0 8.7 3.0
Article number Type of installation
Lamps Mains/Emergency
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671873.92X.y Ceiling (recessed) 1 / 1 18 % 1 x TC‑DEL 13 W • • ‑ 3 h D 188, H 4 DA 175, HE 100
671875.92X.y Ceiling (recessed) 2 / 1 18 % 2 x TC‑DEL 13 W • • ‑ 3 h D 188, H 4 DA 175, HE 100
671874.96X.y Ceiling (recessed) 1 / 1 15 % 1 x TC‑DEL 18 W • • ‑ 3 h D 188, H 4 DA 175, HE 100
671876.96X.y Ceiling (recessed) 2 / 1 15 % 2 x TC‑DEL 18 W • • ‑ 3 h D 188, H 4 DA 175, HE 100
Series: Energo TC 175
Type of protection: IP 23 with bezel ring without safety glass, IP 44 with bezel ring including safety glass Protection class: I Ceiling thickness: 1‑40 mm
For escape route illumination
Modular design: A bezel ring must always be ordered for each basic luminaire!
Recess and bezel ring: die‑cast aluminium, bezel ring with bayonet fixing; bracket: galvanised sheet steel; reflector: aluminium, highly polished anodised finish; installation in ceiling with spring system. EB in separate ballast box with connection cable (L 400 mm) in flexible hose; 5‑pole double terminal for through‑wiring.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X) Basic luminaire: 4 = silver metallic
Panel mounting frame98102.002/176 Panel mounting frame Dimensions 285 x 285 mm
Bezel rings with safety glass, D 194 mm, H 9 mm 981653.002 Safety glass, transparent981653.004 Safety glass, transparent
Bezel rings without safety glass, D 194 mm, H 9 mm981653.102981653.104
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
Ø188 Ø175
HDAD
HE
h
d c b
a
78
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (recessed)
Energo TC 210 Type of protection: IP 23
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Housing made of top quality die-cast aluminium
- Wide luminaire spacing for escape route illumination
- Modern design
- Bezel ring made of die-cast aluminium
- Infinitely adjustable spring fastening system
- EBs in separate ballast box
- Modular recessed luminaire with small recessed depth
- Easy to install
- For ceiling thicknesses of 1-40 mm
79
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (recessed)
Moulded housing981662.000 Moulded housing L 450, B 300, H 200 mm
Spacing table 671881.83X und 671882.83X
Lamp luminous flux:
Mains: 1800 lm, Emergency: 252 lm
The following values are indicated in m
h a b c d
2.5 9.4 3.8 9.4 3.8
3.0 10.3 4.1 10.3 4.1
3.5 11.0 4.1 11.0 4.1
4.0 11.5 4.1 11.5 4.1
Article number Type of installation
Lamps Mains/Emergency
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671881.83X.y Ceiling (recessed) 1 / 1 14 % 1 x TC‑TEL 32 W • • ‑ 3 h D 220, H 4 DA 210, HE 120
671882.83X.y Ceiling (recessed) 2 / 1 14 % 2 x TC‑TEL 32 W • • ‑ 3 h D 220, H 4 DA 210, HE 120
Series: Energo TC 210
Type of protection: IP 23 with bezel ring without safety glass, IP 44 with bezel ring including safety glass Protection class: I Ceiling thickness: 1‑40 mm
For escape route illumination
Modular design: A bezel ring must always be ordered for each basic luminaire!
Recessed and bezel ring: die‑cast aluminium; bezel ring with bayonet fixing; bracket: galvanised sheet steel; reflector: alumi‑nium, highly polished anodised finish; installation in ceiling with spring system. EB in separate ballast box wit connection cable L 400 mm in flexible hose, 5‑pole double terminal for through‑wiring.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X) Basic luminaire: 4 = silver metallic
Panel mounting frame98102.002/215 Panel mounting frame Dimensions 285 x 285 mm
Bezel rings with decorative attachment, D 250 mm, H 38 mm 981660.002 Decorative glass, transparent981660.004 Decorative glass, transparent
Bezel rings with safety glass, D 227 mm, H 9 mm 981659.002 Safety glass, transparent981659.004 Safety glass, transparent
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
Ø220 Ø210
HDAD
HE
h
d c b
a
80
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface)
Andho TC Type of protection: IP 23
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Design matches modern architectural styles
- Housing made of top quality die-cast aluminium
- Top quality reflector made of aluminium, highly polished anodised finish
81
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface)
Spacing table 671891.84X und 671892.84X
Lamp luminous flux:
Mains: 1200 lm, Emergency: 168 lm
The following values are indicated in m
h a b c d
2.5 7.7 3.0 7.7 3.0
3.0 8.5 3.3 8.5 3.3
3.5 9.0 3.3 9.0 3.3
4.0 9.3 3.3 9.3 3.3
Article number Type of installation
Lamps Mains/Emergency
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671891.84X.y Ceiling (surface) 1 / 1 14 % 1 x TC‑TEL 18 W • • ‑ 3 h D 230, H 278
671892.84X.y Ceiling (surface) 2 / 1 14 % 2 x TC‑TEL 18 W • • ‑ 3 h D 230, H 278
Series: Andho TC
Type of protection: IP 23 Protection class: I
For escape route illumination
Housing: aluminium extrusion profile, powder‑coated; bezel ring and ceiling base: die‑cast aluminium, powder‑coated, with bayonet fixing; reflector: aluminium, highly polished anodised finish; EB incorporated, 5 pole double terminal for through‑wiring.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colours (X): 2 = white, 4 = silver metallic
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
H
D
178
45178
Ø230
Ø7
h
d c b
a
82
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface)
Andho TC IP 65 Type of protection: IP 65
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Design matches modern architectural styles
- Housing made of top quality die-cast aluminium
- Top quality reflector made of aluminium, highly polished anodised finish
83
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface)
Spacing table 671893.84X und 671894.84X
Lamp luminous flux:
Mains: 1200 lm, Emergency: 168 lm
The following values are indicated in m
h a b c d
2.5 7.6 2.9 7.6 2.9
3.0 8.2 3.2 8.2 3.2
3.5 8.7 3.2 8.7 3.2
4.0 9.0 3.2 9.0 3.2
Article number Type of installation
Lamps Mains/Emergency
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671893.84X.y Ceiling (surface) 1 / 1 14 % 1 x TC‑TEL 18 W • • ‑ 3 h D 230, H 290
671894.84X.y Ceiling (surface) 2 / 1 14 % 2 x TC‑TEL 18 W • • ‑ 3 h D 230, H 290
Series: Andho TC IP 65
Type of protection: IP 65 for indoor use Protection class: I
For escape route illumination
Housing: aluminium extrusion profile, powder‑coated; ceiling base: die‑cast aluminium, powder‑coated, with bayonet fixing; bezel ring: powder‑coated die‑cast aluminium, screwed on the luminaire; safety glass, transparent; reflector: aluminium, highly polished anodised finish; EB incorporated, 5 pole double terminal for through‑wiring.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colours (X): 2 = white, 4 = silver metallic
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
H
D
178
45178
Ø230
Ø7
h
d c b
a
84
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (recessed)
Arelo® Type of protection: IP 20
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Recessed ring made of die-cast aluminium
- Top quality reflector made of aluminium, highly polished anodised finish
- Wide beam light distribution
- All versions with EB in separate ballast box
- Simple spring system for installation without tools
85
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (recessed)
Spacing table 671857.96X und 671859.96X
Lamp luminous flux:
Mains: 1200 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 7.6 3.3 8.3 3.5
3.0 8.5 3.4 9.2 3.8
3.5 9.4 3.1 10.0 3.8
4.0 9.5 3.0 10.7 3.0
Spacing table 671858.95X und 671860.95X
Lamp luminous flux:
Mains: 1800 lm, Emergency: 216 lm
The following values are indicated in m
h a b c d
2.5 7.5 3.0 8.1 3.3
3.0 8.2 2.8 8.9 3.3
3.5 8.5 2.5 9.4 2.5
4.0 8.1 2.2 9.0 2.6
Article number Type of installation
Lamps Mains/Emergency
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671857.96X.y Ceiling (recessed) 1 / 1 15 % 1 x TC‑DEL 18 W • • ‑ 3 h D 218, H 3 DA 200, HE 106
671859.96X.y Ceiling (recessed) 2 / 1 15 % 2 x TC‑DEL 18 W • • ‑ 3 h D 218, H 3 DA 200, HE 106
671858.95X.y Ceiling (recessed) 1 / 1 12 % 1 x TC‑DEL 26 W • • ‑ 3 h D 218, H 3 DA 200, HE 106
671860.95X.y Ceiling (recessed) 2 / 1 12 % 2 x TC‑DEL 26 W • • ‑ 3 h D 218, H 3 DA 200, HE 106
Series: Arelo®
Type of protection: IP 20 Protection class: I Ceiling thickness: 1‑25 mm
For escape route illumination
Recess ring: die‑cast aluminium, powder‑coated; bracket: galvanised sheet steel; reflector: aluminium, highly polished ano‑dised finish; separate ballast box, length of cable between luminaire and ballast box: 400 mm, suitable for through‑wiring
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 2 = white
Cover screens with spring fastening IP 43981734.000 Safety glass, transparent
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
HE
DAD
H
Ø218 Ø200
h
d c b
a
86
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Mondana Type of protection: IP 65
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Design matches modern architectural styles
- Diffuser: glass or PE sintered glass (polyethylene), shockproof
- IP 65 provides safe protection against humidity - dust and insects cannot penetrate the luminaire
- Gore™ diaphragm valve for pressure equalisation and prevention of condensation
- Easy to install
- Wide range of applications thanks to various types of installation
- Lamp replacement without tools
Surface installation (wall, ceiling) D 500 and D 550
Recessed installation (wall and ceiling) DA 625
Semi‑recessed installation (wall, ceiling) DA 390
87
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Accessories | Moulded housing
Moulded housing 981631.002 for Mondana D 500981631.002 for Mondana D 550
Spacing table 671779.86X
Lamp luminous flux:
Mains: 2800 lm, Emergency: 392 lm
The following values are indicated in m
h a b c d
2.5 6.1 2.8 6.0 2.8
3.0 6.3 3.0 6.1 3.0
3.5 8.3 2.9 8.3 2.9
4.0 8.5 2.8 8.5 2.8
Spacing table 671777.86X
Lamp luminous flux:
Mains: 2800 lm, Emergency: 392 lm
The following values are indicated in m
h a b c d
2.5 6.6 2.4 6.6 2.4
3.0 6.8 2.3 6.8 2.3
3.5 6.9 2.1 6.9 2.1
4.0 6.8 1.9 6.8 1.9
Spacing table 671778.00X
Lamp luminous flux:
Mains: 2800 lm, Emergency: 392 lm
The following values are indicated in m
h a b c d
2.5 5.8 2.7 5.6 2.7
3.0 7.6 2.8 7.6 2.8
3.5 7.9 2.7 7.9 2.7
4.0 8.0 2.6 8.0 2.6
Spacing table 671802.00X
Lamp luminous flux:
Mains: 2800 lm, Emergency: 392 lm
The following values are indicated in m
h a b c d
2.5 5.8 2.7 5.6 2.7
3.0 7.6 2.8 7.6 2.8
3.5 7.9 2.7 7.9 2.7
4.0 8.0 2.6 8.0 2.6
Spacing table 671803.00X
Lamp luminous flux:
Mains: 2800 lm, Emergency: 392 lm
The following values are indicated in m
h a b c d
2.5 6.6 2.4 6.6 2.4
3.0 6.8 2.3 6.8 2.3
3.5 6.9 2.1 6.9 2.1
4.0 6.8 1.9 6.8 1.9
Article number Type of installation
Type Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671777.86X.y Wall (surface), Ceiling (surface) Glass 14 % 1 x TC‑F 36 W • • ‑ 3 h D 500, H 128
671778.86X.y Wall (surface), Ceiling (surface) PE 14 % 1 x TC‑F 36 W • • ‑ 3 h D 550, H 135
671803.86X.y Semi‑recessed instal‑lation (wall, ceiling) Glass 14 % 1 x TC‑F 36 W • • ‑ 3 h D 500, H 78
DA 390, HE 100
671802.86X.y Semi‑recessed instal‑lation (wall, ceiling) PE 14 % 1 x TC‑F 36 W • • ‑ 3 h D 550, H 85
DA 390, HE 100
671779.86X.y Wall (recessed), Ceiling (recessed) PE 14 % 1 x TC‑F 36 W • • ‑ 3 h D 650, H 2
DA 625, HE 140
Series: Mondana
Type of protection: IP 65 for indoor use Protection class: I Ceiling thickness: 10‑30 mm
For escape route illumination
Base: plastic (polycarbonate), microstructure coating; diffuser: plastic (polyethylene) or mouth‑blown opal glass, satin finish. Diffuser fastening: screwneck; housing for semi‑recessed installation in walls and ceilings: powder‑coated aluminium. Standard Gore™ Protective Vents diaphragm valve for reduction of condensation.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
Surface installation (wall, ceiling) D 500 and D 550
Recessed installation (wall and ceiling) DA 625
Semi‑recessed installation (wall, ceiling) DA 390
D H
D H
HE
DA
D H
HE
DA
Ø625Ø390
140
5242,5
Ø380
Ø5,5
7065
h
d c b
a
88
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface)
8hfor
accomodation facilities, nursing homes and
multi-storey buildings
(only in Germany)
Flat Polymero® Type of protection: IP 40
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Design matches modern architectural styles
- Compact design
- Extremely high Light Output Ratio of up to 81%
- Easy to install
- Low maintenance costs
- Wide range of applications thanks to various types of installation
89
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface) D 460 Ceiling (surface), Wall (surface) D 515 Ceiling (surface), Wall (surface) D 620
Spacing table 671587.962
Lamp luminous flux:
Mains: 1200 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 5.7 2.2 5.7 2.2
3.0 5.9 2.2 5.9 2.2
3.5 6.1 2.0 6.1 2.0
4.0 6.2 1.6 6.2 1.6
Spacing table 671585.862
Lamp luminous flux:
Mains: 2800 lm, Emergency: 392 lm
The following values are indicated in m
h a b c d
2.5 7.6 3.2 7.6 3.2
3.0 8.4 3.4 8.4 3.4
3.5 8.8 3.4 8.8 3.4
4.0 8.9 3.4 8.9 3.4
Spacing table 671911.95X
Lamp luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
h a b c d
2.5 13.0 5.2 13.0 5.2
3.0 13.1 5.6 13.1 5.6
3.5 14.3 5.8 14.3 5.8
4.0 15.1 6.1 15.1 6.1
Spacing table 671700.34X
Lamp luminous flux:
Mains: 1200 lm, Emergency: 1200 lm
The following values are indicated in m
h a b c d
2.5 10.8 4.6 10.8 4.6
3.0 12.1 4.8 12.1 4.8
3.5 12.8 5.0 12.8 5.0
4.0 12.8 5.2 12.8 5.2
Spacing table 671531.95X.1
Lamp luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
h a b c d
2.5 13.0 5.2 13.0 5.2
3.0 13.1 5.6 13.1 5.6
3.5 14.3 5.8 14.3 5.8
4.0 15.1 6.1 15.1 6.1
Installation scheme available on request
Article number Type of installation
Lamps Mains/Emergency
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671587.96X.1.y Ceiling (surface), Wall (surface) 2 / 1 15 % 2 x TC‑DEL 18 W • • ‑ 3 h D 460, H 120
671700.34X.1.y Ceiling (surface), Wall (surface) 2 / 1 15 % 1 x TC‑TEL 18 W +
2 x TC‑TSE 18 W • • ‑ 3 h D 460, H 120
671531.95X.1.y Ceiling (surface), Wall (surface) 2 / 1 15 % 1 x TC‑DEL 26 W +
1 x TC‑DEL 26 W • • ‑ 3 h D 515, H 150
671585.86X.1.y Ceiling (surface), Wall (surface) 2 / 1 15 % 2 x TC‑F 36 W • • ‑ 3 h D 620, H 155
671911.95X.1.y Ceiling (surface), Wall (surface) 2 / 1 15 % 2 x TC‑DEL 26 W • • ‑ 8 h D 620, H 160
Series: Flat Polymero®
Type of protection: IP 40 Protection class: I
For escape route illumination
Base: metal, powder‑coated. Diffuser: plastic (PMMA), opal. Diffuser fastening: patented push lock.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
D
H
D
H
D
H
78
30246
Ø460
Ø5
23
142
71
26325
Ø620
Ø5
325
h
d c b
a
90
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface)
Flat Polymero® PC with collar Type of protection: IP 20
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Architecturally attractive design
- Compact design
- Easy to install
- With spring system - for opening the luminaire without tools - for gently detaching and positioning the diffuser
91
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface)
Spacing table 671495.962
Lamp luminous flux:
Mains: 1200 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 5.2 2.0 5.2 2.0
3.0 5.8 1.9 5.8 1.9
3.5 4.9 1.6 4.9 1.6
4.0 4.8 1.1 4.8 1.1
Spacing table 671496.962
Lamp luminous flux:
Mains: 1800 lm, Emergency: 216 lm
The following values are indicated in m
h a b c d
2.5 5.7 2.2 5.7 2.2
3.0 5.9 2.2 5.9 2.2
3.5 5.6 2.0 5.6 2.0
4.0 5.6 1.7 5.6 1.7
Spacing table 671497.982
Lamp luminous flux:
Mains: 1200 lm, Emergency: 216 lm
The following values are indicated in m
h a b c d
2.5 5.9 2.3 5.9 2.3
3.0 6.1 2.3 6.1 2.3
3.5 5.7 2.1 5.7 2.1
4.0 5.9 1.8 5.9 1.8
Spacing table 671498.862 / 36 W
Lamp luminous flux:
Mains: 2800 lm, Emergency: 392 lm
The following values are indicated in m
h a b c d
2.5 7.6 3.1 7.6 3.1
3.0 8.3 3.2 8.3 3.2
3.5 8.2 3.2 8.2 3.2
4.0 8.3 3.1 8.3 3.1
Collar for general lighting height adjustment: see our latest product selection guide.
Article number Type of installation
Lamps Mains/Emergency
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671495.96X.y Ceiling (surface), Wall (surface) 1 / 1 15 % 1 x TC‑DEL 18 W • • ‑ 3 h D 310, H 190,
Ø 265
671496.95X.y Ceiling (surface), Wall (surface) 1 / 1 12 % 1 x TC‑DEL 26 W • • ‑ 3 h D 310, H 190,
Ø 265
671498.86X.y Ceiling (surface), Wall (surface) 2 / 1 15 % 2 x TC‑F 36 W • • ‑ 3 h D 420, H 205,
Ø 385
671497.98X.y Ceiling (surface), Wall (surface) 2 / 1 18 % 2 x TC‑L 18 W • • ‑ 3 h D 420, H 205,
Ø 385
Series: Flat Polymero® PC with collar
Type of protection: IP 20 Protection class: I
For escape route illumination
Base: plastic, white, with collar: perforated metal, powder‑coated. Diffuser: plastic (polycarbonate), opal. Diffuser fastening: spring system.
Ballast mains/emergency: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
D
Ø
H
D
Ø
H
90
220266
525
3x120°
Ø6 50
3x120°
384,5335
5,5
h
d c b
a
92
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface)
Flat Basic Type of protection: IP 43
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Architecturally attractive design
- Low maintenance costs
- Compact design
- Easy to install
- With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass
93
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface)
Spacing table 671423.912
Lamp luminous flux:
Mains: 600 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 6.9 2.6 6.9 2.6
3.0 7.0 2.6 7.0 2.6
3.5 7.2 2.5 7.2 2.5
4.0 6.8 2.3 6.8 2.3
Article number Type of installation
Lamps Mains/Emergency
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671423.91X.y Ceiling (surface), Wall (surface) 2 / 1 30 % 2 x TC‑EL 9 W • • ‑ 3 h D 420, H 124
Series: Flat Basic
Type of protection: IP 43 Protection class: I
For escape route illumination
Base: die‑cast aluminium, powder‑coated. opal glass: mouth‑blown, satin finish. Glass fastening: springs.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: LLB/EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
D
H
Ø
21495
50
400
5x8
258
h
d c b
a
94
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface)
Flat Basic with collar Type of protection: IP 20
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Architecturally attractive design
- Low maintenance costs
- Compact design
- Easy to install
- With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass
95
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface)
Spacing table 671493.982
Lamp luminous flux:
Mains: 1200 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 6.9 2.6 6.9 2.6
3.0 7.0 2.6 7.0 2.6
3.5 7.2 2.5 7.2 2.5
4.0 6.8 2.3 6.8 2.3
Spacing table 671455.962
Lamp luminous flux:
Mains: 1200 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 6.9 2.6 6.9 2.6
3.0 7.0 2.6 7.0 2.6
3.5 7.2 2.5 7.2 2.5
4.0 6.8 2.3 6.8 2.3
Spacing table 671456.952
Lamp luminous flux:
Mains: 1800 lm, Emergency: 220 lm
The following values are indicated in m
h a b c d
2.5 7.2 2.9 7.2 2.9
3.0 7.8 2.9 7.8 2.9
3.5 7.5 2.9 7.5 2.9
4.0 8.2 2.8 8.2 2.8
Spacing table 671521.002
Lamp luminous flux:
Mains: 1800 lm, Emergency: 216 lm
The following values are indicated in m
h a b c d
2.5 6.9 2.7 6.9 2.7
3.0 6.9 2.7 6.9 2.7
3.5 7.1 2.6 7.1 2.6
4.0 6.6 2.4 6.6 2.4
Collar for general lighting height adjustment: see our latest product selection guide.
Spacing table 671494.862
Lamp luminous flux:
Mains: 2800 lm, Emergency: 392 lm
The following values are indicated in m
h a b c d
2.5 7.6 3.2 7.6 3.2
3.0 8.4 3.4 8.4 3.4
3.5 8.8 3.4 8.8 3.4
4.0 8.9 3.4 8.9 3.4
Article number Type of installation
Lamps Mains/Emergency
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671521.00X.y Ceiling (surface), Wall (surface) 2 / 1 12 % 2 x E27 25 W +
1 x TC‑DEL 26 W• • ‑ 3 h D 420, H 200,
Ø 265
671455.96X.y Ceiling (surface), Wall (surface) 2 / 1 15 % 2 x TC‑DEL 18 W • • ‑ 3 h D 420, H 200,
Ø 265
671456.95X.y Ceiling (surface), Wall (surface) 2 / 1 12 % 2 x TC‑DEL 26 W • • ‑ 3 h D 420, H 200,
Ø 265
671493.98X.y Ceiling (surface), Wall (surface) 2 / 1 18 % 2 x TC‑L 18 W • • ‑ 3 h D 500, H 205,
Ø 385
671494.86X.y Ceiling (surface), Wall (surface) 2 / 1 15 % 2 x TC‑F 36 W • • ‑ 3 h D 500, H 205,
Ø 385
Series: Flat Basic with collar
Type of protection: IP 20 Protection class: I
For escape route illumination
Especially for use with movement sensors and automatic staircase switches. Base: plastic with perforated metal collar, powder‑coated. opal glass: mouth‑blown, satin finish. Glass fastening: springs.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
D
Ø
H
D
Ø
H
90
220266
525
3x120°
Ø6 50
3x120°
384,5335
5,5
h
d c b
a
96
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Wall (surface) Ceiling (surface), Wall (surface)
Flat Polymero® Rechteck Type of protection: IP 40
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Design matches modern architectural styles
- Very large viewing distance with motifs
- Flat design
- Luminaire can be opened without tools
97
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Wall (surface), Ceiling (surface)
Spacing table 671718.752
Lamp luminous flux:
Mains: 2400 lm, Emergency: 384 lm
The following values are indicated in m
h a b c d
2.5 8.3 3.1 8.3 3.1
3.0 8.7 3.2 8.7 3.2
3.5 9.0 3.1 9.0 3.1
4.0 9.1 3.0 9.1 3.0
Spacing table 671719.752
Lamp luminous flux:
Mains: 3500 lm, Emergency: 332 lm
The following values are indicated in m
h a b c d
2.5 7.7 2.9 7.7 2.9
3.0 8.0 2.9 8.0 2.9
3.5 8.3 2.8 8.3 2.8
4.0 8.3 2.6 8.3 2.6
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
Multi‑Digit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671718.75X.y Wall (surface), Ceiling (surface) 50 m 32 % 2 x T16 (T5) 14 W • • ‑ 3 h L 600, B 320, H 75
671719.75X.y Wall (surface), Ceiling (surface) 50 m 19 % 2 x T16 (T5) 24 W • • ‑ 3 h L 600, B 320, H 75
Series: Flat Polymero® Rechteck
Type of protection: IP 40 Protection class: I Viewing distance: 50 m
For escape route identification (only in case of wall installation) or escape route illumination
Base: metal, powder‑coated. Diffuser: plastic (PMMA), opal. Diffuser fastening: sash lock, plastic.
Please quote symbol number when ordering escape route motifs!
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Mains operation: more than 1lamp Emergency mode: 1 lamp
When used as escape route luminaire, please note luminous flux factors.
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
50 m
L
B H
48 306245320
581
530600
Ø5,5
h
d c b
a
98
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface)
Basic Type of protection: IP 43
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Architecturally attractive design
- Low maintenance costs
- Compact design
- Easy to install
- With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass
99
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface)
Spacing table 671095.912
Lamp luminous flux:
Mains: 600 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 5.8 1.9 5.8 1.9
3.0 5.6 1.7 5.6 1.7
3.5 5.4 1.2 5.4 1.2
4.0 ‑ ‑ ‑ ‑
Spacing table 671112.922
Lamp luminous flux:
Mains: 900 lm, Emergency: 126 lm
The following values are indicated in m
h a b c d
2.5 4.8 1.4 4.8 1.4
3.0 4.6 0.9 4.6 0.9
3.5 ‑ ‑ ‑ ‑
4.0 ‑ ‑ ‑ ‑
Spacing table 671422.912
Lamp luminous flux:
Mains: 600 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 5.8 1.9 5.8 1.9
3.0 5.6 1.7 5.6 1.7
3.5 5.4 1.2 5.4 1.2
4.0 ‑ ‑ ‑ ‑
Article number Type of installation
Lamps Mains/Emergency
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671112.92X.y Ceiling (surface), Wall (surface) 1 / 1 14 % 1 x TC‑DEL 13 W • • ‑ 3 h D 280, H 145
671095.91X.y Ceiling (surface), Wall (surface) 1 / 1 30 % 1 x TC‑EL 9 W • • ‑ 3 h D 280, H 145
671422.91X.y Ceiling (surface), Wall (surface) 2 / 1 30 % 2 x TC‑EL 9 W • • ‑ 3 h D 280, H 145
Series: Basic
Type of protection: IP 43 Protection class: I
For escape route illumination
Base: die‑cast aluminium, powder‑coated. opal glass: mouth‑blown, satin finish. Glass fastening: springs.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: LLB/EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
D
H
Ø
21495
50
280
5x8
258
h
d c b
a
100
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface)
Kreis Type of protection: IP 43
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Design matches modern architectural styles
- Low maintenance costs
- Compact design
- Easy to install
- With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass
101
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface)
Spacing table 671425.912
Lamp luminous flux:
Mains: 600 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 5.8 1.9 5.8 1.9
3.0 5.6 1.7 5.6 1.7
3.5 5.4 1.2 5.4 1.2
4.0 ‑ ‑ ‑ ‑
Article number Type of installation
Lamps Mains/Emergency
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671425.91X.y Ceiling (surface), Wall (surface) 2 / 1 30 % 2 x TC‑EL 9 W • • ‑ 3 h D 280, H 120
Series: Kreis
Type of protection: IP 43 Protection class: I
For escape route illumination
Base: die‑cast aluminium, powder‑coated. opal glass: mouth‑blown, satin finish. Glass fastening: springs.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: LLB/EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
D
H
21495
50
280
5x8
258
h
d c b
a
102
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface)
Rondo Type of protection: IP 43
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Design matches modern architectural styles
- Low maintenance costs
- Compact design
- Easy to install
- With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass
103
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface)
Spacing table 671427.912
Lamp luminous flux:
Mains: 600 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 6.6 2.3 6.6 2.3
3.0 6.6 2.1 6.6 2.1
3.5 6.4 1.8 6.4 1.8
4.0 6.2 1.1 6.2 1.1
Article number Type of installation
Lamps Mains/Emergency
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671427.91X.y Ceiling (surface), Wall (surface) 2 / 1 30 % 2 x TC‑EL 9 W • • ‑ 3 h D 400, H 125
Series: Rondo
Type of protection: IP 43 Protection class: I
For escape route illumination
Base: die‑cast aluminium, powder‑coated. opal glass: mouth‑blown, satin finish. Glass fastening: springs.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: LLB/EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
D
H
Ø
21495
50
400
5x8
258
h
d c b
a
104
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface)
Rounded Maxi Type of protection: IP 55
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Design matches modern architectural styles
- Housing made of top quality die-cast aluminium
- Low maintenance costs
- Compact design
- Easy to install
- IP 55 type of protection - dustproof and protected against water jets
105
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface)
Spacing table 671735.92X
Lamp luminous flux:
Mains: 3600 lm, Emergency: 216 lm
The following values are indicated in m
h a b c d
2.5 6.5 2.1 5.7 1.9
3.0 6.6 2.0 5.8 1.7
3.5 6.5 1.5 5.7 1.3
4.0 6.1 0.2 5.3 0.4
Article number Type of installation
Lamps Mains/Emergency
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671735.92X.y Ceiling (surface), Wall (surface) 2 / 1 14 % 2 x TC‑DEL 13 W • • ‑ 3 h D 400, H 130
Series: Rounded Maxi
Type of protection: IP 55 for indoor use Protection class: I
For escape route illumination
Mounting support and cover ring: powder‑coated aluminium; diffuser: opal glass, silk finish.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast emergency/mains: EB
Available colours (X): 2 = white, 31 = anthracite metallic, 4 = silver metallic
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
HD
260280
120Ø380
Ø400
Ø5
h
d c b
a
106
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface)
Alu-Rund Type of protection: IP 54
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Housing made of sturdy die-cast aluminium
- Low maintenance costs
- Compact design
- Easy to install
- With glass cover
107
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface)
Spacing table 671109.91X
Lamp luminous flux:
Mains: 600 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 6.7 2.5 6.7 2.5
3.0 6.9 2.3 6.9 2.3
3.5 7.1 1.9 7.1 1.9
4.0 6.3 1.4 6.3 1.4
Spacing table 671107.91X
Lamp luminous flux:
Mains: 600 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 6.7 2.5 6.7 2.5
3.0 6.9 2.3 6.9 2.3
3.5 7.1 1.9 7.1 1.9
4.0 6.3 1.4 6.3 1.4
Article number Type of installation
Type Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671107.91X.y Ceiling (surface), Wall (surface)
without guard 30 % 1 x TC‑EL 9 W • • ‑ 3 h D 240, H 130
671109.91X.y Ceiling (surface), Wall (surface)
with guard 30 % 1 x TC‑EL 9 W • • ‑ 3 h D 240, H 130
Series: Alu-Rund
Type of protection: IP 54 for indoor use Protection class: I
For escape route illumination
Base: die‑cast aluminium, powder‑coated. opal glass. Guard: die‑cast aluminium, powder‑coated.
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colours (X): 2 = white, 3 = black
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
D H D H
62
65
42
240
6074
45
Ø6
62
65
42
240
6074
45
Ø6
h
d c b
a
108
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Ceiling (surface), Wall (surface)
Weatherproof battens Type of protection: IP 65
- IP 65 type of protection - dustproof and protected against water jets from all directions
- Industrial design
- Lamp replacement without tools
109
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface), Wall (surface) 36 W Ceiling (surface), Wall (surface) 58 W
Spacing table 671093.759
Lamp luminous flux:
Mains: 3350 lm, Emergency: 436 lm
The following values are indicated in m
h a b c d
2.5 8.2 3.3 11.7 4.5
3.0 8.4 3.4 11.7 4.6
3.5 9.0 3.5 12.1 4.7
4.0 9.5 3.5 12.0 4.7
Spacing table 671446.759
Lamp luminous flux:
Mains: 5200 lm, Emergency: 432 lm
The following values are indicated in m
h a b c d
2.5 8.1 3.2 11.6 4.5
3.0 8.4 3.4 11.6 4.6
3.5 9.0 3.5 12.1 4.7
4.0 9.5 3.5 12.0 4.7
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671093.75X.y Ceiling (surface), Wall (surface) ‑ 13 % 1 x T26 (T8) 36 W • • ‑ 3 h L 1258, B 62, H 122
671446.75X.y Ceiling (surface), Wall (surface) ‑ 8 % 1 x T26 (T8) 58 W • • ‑ 3 h L 1558, B 62, H 122
Series: Weatherproof battens
Type of protection: IP 65 for indoor use Protection class: I
For escape route illumination
Base: plastic, grey. Lamp: open beam
operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colour (X): 9 = grey
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
Accessories | Protective tubes for weatherproof battens
Replacement diffuser, plastictransparent981441.000 L 1170, D 38 for T26 36 W981442.000 L 1470, D 38 for T26 58 W
H
BL
H
BL
62
740
1258
Ø10
62
1050
1558
Ø10
h
d c b
a
110
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
Hand‑held LED safety spotlight Safety stand spotlight
Hand-held LED safety spotlight Type of protection: IP 54
- LED technology
- Charging level display
- Shockproof plastic housing
- Universal mounting adaptor included
Safety stand spotlight Type of protection: IP 54
- IP 54 type of protection - dustproof and protected against water spray
- Functional design
- Robust materials
- For high rooms
111
EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Hand‑held LED safety spotlight
Hand‑held LED safety spotlight
Safety stand spotlight
Safety stand spotlight
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
671824.00X.y ‑ ‑ ‑ 1 x LED 3,35 W ‑ ‑ ‑ 4 h L 160, B 155, H 285
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
Multi‑Digit (.04)
DALI (.07)
Rated operat‑ing time
Dimensions
65940 ‑ ‑ ‑ 2 x QT‑H3 55 W ‑ ‑ ‑ 1 h L 500, B 165, H 500
65942 ‑ ‑ ‑ 2 x QT‑H3 55 W ‑ ‑ ‑ 3 h L 500, B 165, H 500
65936 ‑ ‑ ‑ 2 x QT9 (axial) 20 W ‑ ‑ ‑ 1 h L 318, B 160, H 410
65938 ‑ ‑ ‑ 2 x QT9 (axial) 20 W ‑ ‑ ‑ 3 h L 500, B 165, H 500
Series: Hand-held LED safety spotlight
Type of protection: IP 54 Protection class: II in charging mode; Protection class: III in battery mode
Luminaire housing: plastic, grey. Ergonomically designed one‑hand handle, black. Front frame: plastic, red. Cover: polycarbonate, transparent, with four‑coloured light scatter disk attachment. Universal mounting adaptor: metal, painted. Integrated charger: 230 V at 50/60 Hz. Automatic changeover from quick to trickle charging.Preselec‑tion between static and flashing light mode possible. operation of the LED lamp at 100% or 10% performance. Maintenance‑free NiCd rechargeable battery 6 V / 4.0 Ah, charge status indicator.
Charge in dry rooms only!
operating time in static mode: LED lamp 100% > 4 h, LED lamp 10% > 13.5h
Available colour (X): 9 = grey
Series: Safety stand spotlight
Type of protection: IP 54 Protection class: I
Luminaire housing: metal, grey, powder‑coated. Luminaire tops: swivelling. Safety glass: transparent. Lamps included.
operating mode: Non‑maintained (BS), maintenance‑free Pb storage batteries.
B
L H
H
180
L B
112
NiCd-Akku
FL
654321
E
ST/AB-Bus
Prüftaster230V 50/60Hz
LEL‘NLPE rot
schwarz+
NiCd-Akku
FL
654321
E
ST/AB-Bus
Prüftaster
230V 50/60HzLEL‘NLPE rot
schwarz+
Lichtschalter
zurAllgemeinbe-
leuchtung
FL
Mit 2 Lampen
Mit 1 LampeKVG/VVG
KVG/VVG
Lichtschalter
zurAllgemeinbe-
leuchtung
S
S
S
(NiMH)
(NiMH)
113
Self-contained emergency conversion kits
Emergency conversion kits 114 - 116
Power supply units 116 - 117
Emergency power supply units 118
Connecting diagrams 119 - 121
114
EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS
Emergency conversion kits
Emergency lighting fitment
Power supply units
Conversion kits
System benefits
- High luminous flux factor reduces number of required luminaires
- Large LED display (5 mm)
- Constant light current control
- Complete series (standard, self-test, MultiDigit®)
- Universally suited for LLB/EB, irrespective of manufacturer
- Conversion kits for DALI available (upon request)
Universal installation kit for luminaires of general purpose lighting
ideally suited for converting general purpose lighting luminaires into self-contained emergency luminaires.
type of protection: iP 20 Protection class: i
Electronic module housing: metal, galvanised. Charging indicator lamp (LEd): standard. niCd high-temperature rechargeable battery and instructions for retrofitting this module into existing luminaires are included.
the modules conform to vdE0108 and En60598, part 2-22.
after conversion the luminaire can be operated in maintained or non-maintained power mode.
this module can be used together with the low-lost ballast (4-pin lamp holder, external starter required) or EB of the luminaire.
the ballast in the luminaire controls operation of the lamp(s) when mains power is applied. Should the mains power supply fail, one lamp is automatically powered by the battery via the emergency conversion kit.
Connecting diagramms: see pages 119 - 120
Please note:
Constant phase = charging phase,
must always be connected to L.
L’ and L must use the same phase.
The circuit must be potential-free.
Self-contained luminaire, maintained (DS)
L' L N PE
General purpose lighting
230 V / 50 Hz
Self-contained luminaire,non-maintained (BS)
L' L N PE
Sub distribution boardGeneral purpose lighting
General purpose lighting
230 V / 50 Hz
Sub distribution boardGeneral purpose lighting
Self-contained luminaire, maintained (DS)
L' L N PE
General purpose lighting
230 V / 50 Hz
Self-contained luminaire,non-maintained (BS)
L' L N PE
Sub distribution boardGeneral purpose lighting
General purpose lighting
230 V / 50 Hz
Sub distribution boardGeneral purpose lighting
115
EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS
tender texts available upon request | Specifications subject to alteration
the above indicated luminous flux factors are recommended hypothetical values for ambient temperatures of 25° C. inasmuch as colour rendering and luminous flux in emergency mode are mainly determined by lamp temperature and/or luminaire design and construction, light should be measured at lower temperatures for each type of luminaire. any lamp manufactured with amalgam techno-logy, such as the Philips PL-t toP, shall be excluded and shall be subject to prior testing. only quality products from reputable vendors are to be used. the values in the table above are intended as recommendations only and are subject to change. all applications shall be subject to prior testing. We reserve the right to effect changes in the table above without prior notice.t16/t5 tubes have a so-called “cold spot” at the tip of the tube, usually positioned at that tube tip which bears the lettering. for improved emergency mode, this cold spot or tube tip should be connected to outputs 6 and 8 of the lamp terminal. the luminaire should be marked in such a way as to ensure that the tube is inserted in the right direction.
Standard emergency conversion kits 6 – 80 W (battery included)
Nom. operating time 1h Nom. operating time 3h
Standard module
Catalogue number: 09-6284.000 09-6287.000
Self-test module (version .03)
Catalogue number: 09-6285.000 09-6288.000
MultiDigit® module (version .04)
Catalogue number: 09-6286.000 09-6289.000
Lamp/Wattage Luminous flux factor mains/emergency in %
t16 6 W 50 % 50 %t16 8 W 37 % 37 %t16 13 W 23 % 23 %t16 14 W 21 % 21 %t16 21 W 14 % 14 %t16 24 W 12 % 12 %t16 28 W 10 % 10 %t16 35 W 8 % 8 %t16 39 W 7 % 7 %t16 49 W 6 % 6 %t16 54 W 5 % 5 %t16 80 W 3 % 3 %t26 10 W 30 % 30 %t26 15 W 20 % 20 %t26 16 W 18 % 18 %t26 18 W 16 % 16 %t26 30 W 10 % 10 %t26 36 W 8 % 8 %t26 58 W 5 % 5 %tC-L 18 W 16 % 16 %tC-L 24 W 12 % 12 %tC-L 36 W 8 % 8 %tC-L 40 W 7 % 7 %tC-L 55 W 5 % 5 %tC-EL 5 W 50 % 50 %tC-EL 7 W 42 % 42 %tC-EL 9 W 33 % 33 %tC-EL 11 W 27 % 27 %tC-dEL 10 W 30 % 30 %tC-dEL 13 W 23 % 23 %tC-dEL 18 W 16 % 16 %tC-dEL 26 W 11 % 11 %tC-tEL 18 W 16 % 16 %tC-tEL 26 W 11 % 11 %tC-tEL 32 W 9 % 9 %tC-tEL 42 W - -t16-r 22 W 13 % 13 %t16-r 40 W 7 % 7 %t16-r 55 W 5 % 5 %t16-r 60 W 5 % 5 %t29-r 22 W 13 % 13 %t32-r 32 W 9 % 9 %t32-r 40 W 7 % 7 %
module dimensions 180 x 40 x 28 180 x 40 x 28Battery 4,8 v/1,8 ah 4,8 v/4,5 ahBattery dimensions d 24, L 2 x 88 d 33, L 242
Spare battery Spare battery 67000.0.61 67000.0.62
Emergency conversion kits with high luminous flux factor 14 – 80 W (battery included)
Nom. operating time 1h Nom. operating time 3h
Standard module
Catalogue number: 09-6290.000 09-6293.000
Self-test module (version .03)
Catalogue number: 09-6291.000 09-6294.000
MultiDigit® module (version .04)
Catalogue number: 09-6292.000 09-6295.000
Lamp/Wattage Luminous flux factor mains/emergency in %
t16 6 W - -t16 8 W - -t16 13 W - -t16 14 W 49 % 32 %t16 21 W 32 % 21 %t16 24 W 28 % 18 %t16 28 W 24 % 16 %t16 35 W 19 % 12 %t16 39 W 17 % 11 %t16 49 W 14 % 9 %t16 54 W 12 % 8 %t16 80 W 8 % 5 %t26 10 W 69 % 45 %t26 15 W 46 % 30 %t26 16 W 43 % 28 %t26 18 W 38 % 25 %t26 30 W 23 % 15 %t26 36 W 19 % 12 %t26 58 W 11 % 7 %tC-L 18 W 38 % 25 %tC-L 24 W 28 % 18 %tC-L 36 W 19 % 12 %tC-L 40 W 17 % 11 %tC-L 55 W 12 % 8 %tC-EL 5 W - -tC-EL 7 W - -tC-EL 9 W - -tC-EL 11 W - -tC-dEL 10 W - -tC-dEL 13 W - -tC-dEL 18 W 38 % 25 %tC-dEL 26 W 26 % 17 %tC-tEL 18 W 38 % 25 %tC-tEL 26 W 26 % 17 %tC-tEL 32 W 21 % 14 %tC-tEL 42 W 16 % 10 %t16-r 22 W 31 % 20 %t16-r 40 W 17 % 11 %t16-r 55 W 12 % 8 %t16-r 60 W 11 % 7 %t29-r 22 W 31 % 20 %t32-r 32 W 21 % 14 %t32-r 40 W 17 % 11 %
module dimensions 180 x 40 x 28 180 x 40 x 28Battery 4,8 v/4,5 ah 7,2 v/4,5 ahBattery dimensions d 33, L 242 d 33, L 2 x 182
Spare battery Spare battery 67000.0.62 67000.0.63*
* 2 batteries required
116
EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS
tender texts available upon request | Specifications subject to alteration
Emergency conversion kitsPower supply unitsIdeally suited for converting general purpose lighting luminaires into self-contained safety luminaires
type of protection: iP 30 Protection class: i
housing: metal, powder-coated. niCd rechargeable battery included.
the low-loss ballast (4-pin lamp holder, external starter required) or the EB of the luminaire to be converted powers the lamp in mains mode. the emergency light module automatically powers the lamp in emergency mode. Switching mode: either maintained mode or non-maintained mode. Luminaire equipment, power supply units: charging indicator (LEd), standard. maintenance-free niCd rechargeable batteries.
nominal operating time: 1 or 3 hours. max. length of cable between emergency supply unit and lamp: LLB = 2 m, EB = 0.5 m. Permissible ambient temperature: 0 -40° C. Luminous flux factors, see previous page.
available colours: 2 = white, 3 = black
Emergency conversion kit for fluorescent lampsin recessed or surface mounted housingL 390, B 100, H 55981158.003 1h 28 W 2.3 kg981158.003.03 1h 28 W 2.3 kg981158.003.04 1h 28 W 2.3 kg981159.003 3h 28 W 2.3 kg981159.003.03 3h 28 W 2.3 kg981159.003.04 3h 28 W 2.3 kg981160.003 1h 65 W 2.3 kg981160.003.03 1h 65 W 2.3 kg981160.003.04 1h 65 W 2.3 kg981161.003 3h 65 W 2.5 kg981161.003.03 3h 65 W 2.5 kg981161.003.04 3h 65 W 2.5 kg
Emergency conversion kit for fluorescent lampsin surface mounted housing, with luminaire suspension eyeletL 340, B 170, H 75981162.002 1h 28 W 1.7 kg981162.002.03 1h 28 W 1.7 kg981162.002.04 1h 28 W 1.7 kg981163.002 3h 28 W 1.7 kg981163.002.03 3h 28 W 1.7 kg981163.002.04 3h 28 W 1.7 kg981164.002 1h 65 W 1.7 kg981164.002.03 1h 65 W 1.7 kg981164.002.04 1h 65 W 1.7 kg981165.002 3h 65 W 1.9 kg981165.002.03 3h 65 W 1.9 kg981165.002.04 3h 65 W 1.9 kg
L
B
H
L
B
H
117
EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS
tender texts available upon request | Specifications subject to alteration
NCH complete conversion kitIdeally suited for converting general purpose lighting luminaires into self-contained emergency luminaires.
for low-voltage halogen lamps of up to 50 W, voltage: 6 v. nominal operating time: 1 or 3 hours.
housing: L 183, B 40, h 32rechargeable battery 6 v/4,0 ah: L 312, B 40, h 32.
09-6019.000 Qt max. 50 W 2 h/100 % 6 v 10 W
1 h/100 % 6 v 20 W
5 h/ 10 % 12 v 10 W
2 h/ 10 % 12 v 20 W
1 h/ 10 % 12 v 35 W
1 h/ 10 % 12 v 50 W
NCH safety conversion kitIdeally suited for converting general purpose lighting luminaires into self-contained safety luminaires
nominal operating time: 1 or 3 hours. max. length of cable between emergency supply unit and lamp: 1m. Luminous flux factors, see table on page 115.
Safety conversion kits for low-voltage halogen lamps in recessed or surface mounted housing (black module)
981127.003 L 390, B 100, h 55
in surface mounted housing, with luminaire suspension eyelet (white module)
981128.002 L 340, B 170, h 75
Luminous flux factors, see nCh complete conversion kit
(wattage/voltage see, nCh complete conversion kit)
L
B
H
L
B
H
L
L
H
B
B
H
118
EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS
tender texts available upon request | Specifications subject to alteration
Emergency power supply unit PGVG 200PGVG 200 is a self-contained emergency power supply unit pursuant to DIN EN 60598-2-22 for operating 1 or 2 luminaires over an operating period of 1 or 3 hours.
max. distance between Pgvg and luminaires: 200 m
type of protection: iP 33
Protection class: i
mains supply: 1/n 230 v; max. 0.25 a; 50 hz
output voltage: 230 v / 50 hz (mains) 170 – 225 v (battery)
Permissible ambient temperature: +5 to +25° C.
device is equipped with a protective earth connection.
Electronics
Electronic module with charging device, 2 mains monitors, 2 changeover facilities, dC-dC converter or dC-aC converter, 2 lighting circuits, deep discharge protection disconnection and automatic self-monitoring.
non-maintained or maintained power mode of the luminaires. Separate luminaire inputs and outputs as well as control inputs for switching the luminaires by lighting circuit in mains mode.
the battery is charged via input 1. in the event of a power failure on input 1 and/or input 2, the charging process will be interrupted and output 1 and/or 2 will be powered by the battery. Upon return of the mains power supply, the device switches back from battery to mains operation mode with a delay of 10 seconds.
in mains mode, the luminaires can be individually switched from non-maintained to maintained mode via control input 1 and control input 2.
the device switches off automatically in case of overheat, overload or short circuit during battery mode.
the standard self-monitoring function provides for automatic weekly function tests (charging device, changeover facility and lighting circuits) as well as yearly service life tests (battery capacity). the luminaires will be controlled by a self-adjusting rating monitor. a display and foil button indicate operating states and malfunctions and allow for manual activation of function tests. Collective errors can be forwarded to an external alarm system via an alarm output. Battery device with maintenance-free, sealed Pb battery (service life: 6 – 9 years according to EUroBat). the battery installation must comply with the manufacturer’s instructions. the battery must always be positioned with the pole pointing vertically upwards.
Luminaire 4 can be connected to terminals 5/6.
Mechanics
Battery and electronics are incorporated in separate housings according to din En 50272-2. Battery device with ventilation opening. Screwed housing can be folded open laterally. Wiring through cable ducts.
Similar to illustration
Types
Emergency power supply unit for operating 1 or 2 luminaires fitted with incandescent lamp or low pressure discharge lamp with electronic ballast, complying with self-contained system pursuant to din En 60598-2-22. the indicated wattages refer to the entire device and are divided among 2 outputs. the minimum wattage for lamp control is 13 w per output.
Catalogue no. type dimensions (LxBxh) Wattage981502.000 nvg200-7-dC-g 510 x 200 x 100 29 W/1h 12 W/3h
981504.000 nvg200-12-dC-g 510 x 200 x 170 50 W/1h 21 W/3h
981506.000 nvg200-18-dC-g 510 x 200 x 100 74 W/1h 31 W/3h
981508.000 nvg200-26-dC-g 510 x 200 x 170 106 W/1h 45 W/3h
981510.000 nvg200-45-dC-g 635 x 240 x 190 183 W/1h 78 W/3h
981512.000 nvg200-90-dC-g 950 x 240 x 190 200 W/1h 156 W/3h
N L2 L1
DATAPEL1NPEL2NPE
PE N (L2) L1
DATA
1
Connecting diagramm PGVG 200
256
A1
a1
PE
A2
a2
PE
4
3
L B
H
119tender texts available upon request | Specifications subject to alteration
EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS
the diagrams shown below refer to emergency conversion kits with the following article numbers
Standard Self test (.03) MultiDigit (.04)
09-6058.000 09-6042.000 09-6022.00009-6059.000 09-6043.000 09-6023.00009-6083.000 09-6044.000 09-6024.00009-6061.000 09-6045.000 09-6025.000
Attention: Connection diagrams with more than one lamp: one lamp starts in emergency mode.
in case your luminaires/EB are not suitable for these diagrams, please do not hesitate to contact us. We are looking forward to helping you.
Legend:
DA BUS connecting terminal for daLi interface .07
ST BUS connecting terminal for PZ 50, version with self test function .03
AB BUS connecting terminal, version for multidigit® .04
Connecting diagram 2: maintained, with CB/LLB for self-contained emergency conversion kits
Connecting diagram 1: non-maintained
Please note:
Constant phase = charging phase
must always be connected to L.
L’ and L must use the same phase.
The circuit must be potential-free.
Self-contained emergency conversion kits
Connecting diagrams
BUS portMultiDigit .04
PENLL' A B TSL' L N PE
BUS portPZ50 .03
BUS portDALI .07
PENLL' DADA
120
EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS
tender texts available upon request | Specifications subject to alteration
Connecting diagram 3: maintained, with EB
Self-contained emergency conversion kits
Connecting diagrams
EB with6 terminals
EB with7 terminals
EB with8 terminals
121
EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS
tender texts available upon request | Specifications subject to alteration
Self-contained emergency conversion kits
Connecting diagrams (Turia / Edo)
Turia / Edo: non-maintained, with DALI port
Turia / Edo: non-maintained
Turia / Edo: maintained, with DALI port
Turia / Edo: maintained
NLPE
NiMH-Akku
(NiCd)
+ red- black
230 V / 50/60 Hz
DADA
DALI BUSport
(NiCd)
NLPE
NiMH-Akku
+ red- black
230 V / 50/60 Hz
L'NLPE
NiMH-Akku
+ red- black
test button230 V / 50/60 Hz
light switchDADA
DALI BUSport
(NiCd)
L'NLPE
NiMH-Akku
+ red- black
test button230 V / 50/60 Hz
light switch
(NiCd)
122
123
Central battery systems (CPS) 127
RZBbasic central battery system with fused output circuits 128 - 131
LUXIFAIR modular central battery system 132 - 137
(Sub-stations can be connected)
LUXIFAIRlight modular central battery system 138 - 140
(Sub-stations cannot be connected)
Group battery systems (LPS) 141
GV 1500 19“ group battery system 142 - 143
RZBeasy group battery system 144 - 147
Accessories
Monitoring modules, message and switchboards, etc. 148 - 157
Battery cabinets 124 - 125
124
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
charging
continuous charging
0% 20% 40% 60% 80% 100%
2.40 1.55
2.23 1.45
2.00 1.20
IN
V/Zlead NiCd
Battery cabinetsAll of the housings listed below are powder-coated and enamelled.
housing material: Sheet steel
type of protection: IP 21
colour: housing and doors RAL 7035 (light grey)
type Dimensions catalogue no.
RZB BS0 900 x 600 x 500 mm 985377 RZB BS8.20-3G 1800 x 600 x 600 mm 985238 RZB BS8.21-3G 1800 x 800 x 600 mm 985107
Other battery cabinets available on request.
All doors are right hinged. Free-standing housing doors open to an angle of 180 °. housing bases with a height of 100 or 200 mm are available for adjustment to other housings. All housings are available in other colours at extra cost.
cables can be channelled from below or above (rear) into the free-standing housings, but only from above in case of wall-mounted housings. cable inlets from above (rear) are standard for emergency lighting equipment.
the front and rear panels of all housings can be removed for transportation purposes.
Charging and charge maintenance devicethe charging and charge maintenance device’s functioning is based on the current voltage curve (I-U characteristics).
the charging device is powerful enough to ensure that the battery will be recharged to 80% of its nominal capacity within 12 hours. It can also be used to charge low-maintenance and maintenance-free batteries.
Charging voltage
2.40 V/Z ± 1% wet cell batteries
2.35 V/Z ± 1% maintenance-free batteries
1.55 V/Z ± 1% nicd batteries
Continuous charging voltage
2.23 V/Z ± 1% wet cell batteries
2.3 V/Z ± 1% maintenance-free batteries
1.4 - 1.45 V/Z ± 1% nicd batteries
Batteries- Sealed, rechargeable block batteries
- type: OGiV (other types on request)
- Designlife: 10 years at 20°c ambient temperature
- Extremely low gassing rate
- Low self-discharge
- Various capacities in 12 V blocks
- 100% recyclable
125
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
Calculating the aeration and ventilation of electr. operation rooms
Larger battery capacities can be achieved by parallel arrangement of identical battery types.
Example:
If a battery capacity of 169 Ah and 216 V is required for 3 hours, 2 x 18 battery blocks, type BtX 12-100, are paralleled. this doubles the battery capacity from 84.60 to 168.20.
this type of arrangement is recommended fort he following battery types:
BtX 12-120 LS BtX 12-134 LS BtX 12-150 LS BtX 12-200 LS
Sta
tiona
ry, s
eale
d m
ain-
tena
nce-
free
lead
bat
tery
(O
GiV
)
Max
. lum
inai
re w
atta
ge
8h
Max
. lum
inai
re w
atta
ge
3 h
Max
. lum
inai
re w
atta
ge
1h
Air
volu
me
flow
Q [m
3 /h]
for
vent
ilatin
g th
e in
stal
latio
n ro
om
Ven
tilat
ion
cros
s se
ctio
ns
per
sup
ply
and
exh
aust
air
open
ing
in th
e in
stal
latio
n ro
om A
[cm
2 ] (n
atur
al
vent
ilatio
n)
Sq
uare
rec
ess
pe
r su
pply
and
exh
aust
air
op
enin
g, la
tera
l len
gth
[cm
]
Pip
epe
r su
pply
and
exh
aust
air
open
ing,
nom
inal
dia
met
er
[mm
]
num
ber
of b
atte
ry c
abin
ets
Bat
tery
cab
inet
sM
inim
um r
equi
rem
ents
for
use
of 1
8 bl
ocks
Dim
ensi
ons
of
batte
ry c
abin
et
[B x
t x
h]
17 Ah 429 W 1074 W 2786 W 0,78 m3/h 21,83 cm2 4,67 cm 52,73 mm 1 Stck BS 8.20 - 3G 600 x 600 x 1800
24 Ah 605 W 1414 W 3618 W 0,99 m3/h 27,80 cm2 5,27 cm 59,51 mm 1 Stck BS 8.20 - 3G 600 x 600 x 1800
28 Ah 761 W 1782 W 4417 W 1,18 m3/h 32,92 cm2 5,74 cm 64,76 mm 1 Stck BS 8.20 - 3G 600 x 600 x 1800
33 Ah 874 W 2030 W 4752 W 1,39 m3/h 39,02 cm2 6,25 cm 70,50 mm 1 Stck BS 8.20 - 3G 600 x 600 x 1800
45 Ah 1166 W 2548 W 5886 W 1,92 m3/h 53,65 cm2 7,32 cm 82,67 mm 1 Stck BS 8.20 - 3G 600 x 600 x 1800
55 Ah 1468 W 3261 W 7668 W 2,14 m3/h 59,99 cm2 7,75 cm 87,42 mm 1 Stck BS 8.20 - 3G 600 x 600 x 1800
75 Ah 2008 W 4179 W 9558 W 3,18 m3/h 89,01 cm2 9,43 cm 106,48 mm 1 Stck BS 8.20 - 3G 600 x 600 x 1800
80 Ah 2170 W 4644 W 10778 W 3,44 m3/h 96,32 cm2 9,81 cm 110,77 mm 1 Stck BS 8.21 - 3G 800 x 600 x 1800
90 Ah 2386 W 5119 W 12312 W 3,88 m3/h 108,52 cm2 10,42 cm 117,57 mm 1 Stck BS 8.21 - 3G 800 x 600 x 1800
100 Ah 2754 W 6145 W 14296 W 4,31 m3/h 120,71 cm2 10,99 cm 124,00 mm 1 Stck BS 8.21 - 3G 800 x 600 x 1800
120 Ah 3315 W 7171 W 17064 W 5,18 m3/h 145,09 cm2 12,05 cm 135,95 mm 2 Stck BS 8.21 - 3G 800 x 600 x 1800
134 Ah 3996 W 8996 W 20628 W 5,37 m3/h 150,46 cm2 12,27 cm 138,44 mm 1 Stck BS 8.21 - 3G 800 x 600 x 1800
150 Ah 4158 W 8888 W 21384 W 6,23 m3/h 174,36 cm2 13,20 cm 149,03 mm 2 Stck BS 8.20 - 3G 600 x 600 x 1800
200 Ah 5572 W 12528 W 28404 W 8,67 m3/h 242,64 cm2 15,58 cm 175,81 mm 2 Stck BS 8.21 - 3G 800 x 600 x 1800
Discharge data refer to 108 cells (18 blocs) at 25°.
127
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
Central battery systems (CPS) in comparison
type of system RZBbasic LUXIFAIR LUXIFAIRlight
Modular technology • • •
Free programmable final circuits (maintained, non maintained) – • •
DUO control technology, mixed operati-on mode (maintained, non maintained, switchable mode)
– • •
circuit monitoring optional • •
Single luminaire monitoring (without BUS line) optional • •
with control 1 optional – –
Single control – • •
Duo control – • •
Switches
UE220i (for installation in luminaires)optional optional optional
UE220e (for installation in distribution boards) optional optional optional
Sub distribution board optional optional –
Sub-station (with same changeover and reporting functions as base) optional optional –
Visualisation – optional optional
network connection – • •
Staircase light switching optional • –
Voltage [V] 24/42/60/110/216 216 216
DS = maintained | BS = non-maintained | GDS = switched maintained | TLS = staircase light circuit
128
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
RZBbasic
- Fully automated, processor-controlled monitoring system
- Modular structure
- Sheet steel cabinet
- Central monitoring of sub distribution boards
- Free programming of all system and customer data
- Single luminaire monitoring and circuit monitoring, optional
- Basic version with battery voltage 216 V (220 V), other battery voltages (24 V, 42 V, 60 V, 110 V) on request
- E30 or E90 twin cabinets can also be supplied upon request
Central battery system (CPS)
type of protection: IP 21 Protection class: I
RZBbasic is a series of modular systems; the number and the distribution of the circuits are to be determined beforehand. the system can be configured individually.
RZBbasic comes complete with a control unit, plastic foil keyboard and four-line display.
Available colour for housing and doors: RAL 7035 (light grey)
Additional RZBbasic options
Battery cabinet
page 124
Sub distribution boardpage 131
For more RZBbasic options: see page 148 et seqq.
Monitoring module
cOntROL1 for installation in luminaires
UE220i switch
for installation in luminaires
UE220e switch
for installation in distributors
Printer for operating status messages and testing protocols
3-phase network monitoring module
Message and switchboard
129
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
RZBbasic installation example
Sub distribution board
Fused outlet circuits with circuit or single luminaire monitoring without changeover facility
In case of sub distribution boards with BUS connection, please note: if the sub distribution board is more than 100 m away from the main station, it must be fitted with a BUS amplifier. Max. BUS line length: 1,000 m.
the BUS can be connected in series or star-shaped (max. 6 star points). Each system provides 2 standard BUS terminals.
BU
S li
ne
Lum
inai
re (n
on m
aint
aine
d)
Lum
inai
re (m
aint
aine
d)
circuit 1
circuit 1
circuit 1
circuit 2
circuit 2
circuit 2
circuit 3
circuit 3
circuit 4
circuit 4
housing according to En 50272 and EltBau Vo
500
m
500
m 500 m
500 m
1000 m
130
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
housing with charging and charge maintenance device
the housing is powder-coated and enameled. All doors are right-hinged. Free-standing housing doors open to an angle of 180 °. housing bases with a height of 100 or 200 mm are available for adjustment to other housings. All housings are available in other colours at additional cost.
Available as a twin cabinet with battery compartment or electronic housing with separate battery cabinet.
Technical specifications
Dimensions: 1800 x 800 x 600 mm, 1200 x 600 x 430 mm
Mains connection: type E – single-phase alternating current 230 V 50 hz
type D – three-phase current 400 V 50 hz
Mains voltage: Un ± 10%
Form factor: three-phase current: approx. 1.1; alternating current: approx. 1.4
Level of radio interference: „n“ according to VDE 0875
housing: Protection type IP 21
Available colour: housing and doors RAL 7035 (light grey)
Protection class: the appliances correspond to protection class I
Operating temperature: 0°c - 40°c at max. installation height of 1,000 m above zero level
Residual ripple: < 5% with parallel arranged battery
RZBbasic
Components
Microprocessor control and monitoring unit (standard)
- Illuminated plain text display: 4 lines with 16 characters each
- Plastic foil keyboard
- Buffer storage for reports and function tests dating back 2 years
- 4 integrated timers for maintained light circuits control
- Simple BUS connection of sub distribution boards
- Potential separation of the processor unit ensures high level of interference immunity
- Serial RS232 interface on the door for connection of a Pc for data collection (standard)
- central control unit interface: all reports with opening and closing contact
- Outgoing circuits can be individually programmed as maintained, non-maintained or switched maintained light
- Simple to service thanks to the plug-in connections on all modules
Microprocessor control and monitoring unit
2-pole fused outgoing circuits
Battery compartment with grid trays. the grid trays provide better ventilation, especially of the middle batteries, which prolongs their service life.
131
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
Design: steel cabinet
Paint coating: housing and doors RAL 7035 (light grey)
type of protection: IP 21
Fitting: up to 36 x D01/D02 or 26 x circuit breakers
Fire-protected housing also avilable. A BUS interface circuit board can also be installed (necessary for circuit or single monitoring).
type Dimensions max. D01/LSS
E1/UV 600 x 400 x 250 16/14E2/UV 800 x 400 x 250 24/21
RZBbasic
Sub distribution boards
Design: steel cabinet
Paint coating: housing and doors RAL 7035 (light grey)
type of protection: IP 21
Ready for installation of changeover facilities, circuit monitoring or single luminaire monitoring and for BUS connection to the master device. the following must be installed if sub-stations with switching facilities are to be used:
1. control PcB
2. Bus interface PcB
3. network monitoring module for sub distribution board
4. Switching equipment, circuits, monitoring equipment
type Dimensions max. D01/D02/LSS
E3 UV 800 x 600 x 250 24/24/18nL8.21-UV 1800 x 800 x 400 79/79/60
Fire-protected housing E-30
Design: 30 minutes fire-protected housing, tested in line with DIn 4102 Part 12
Attention: Distributors and module cabinets are not equipped.
type Dimensions max. D01/LSS
t1 UV-E30 1000 x 730 x 400 housing for fuses 12/18
t2 UV-E30 1150 x 890 x 400 housing for fuses 30/30
t3 UV-E30 2050 x 730 x 400 Module cabinet 60/72
t4 UV-E30 2050 x 1230 x 400 Module cabinet 120/120
132
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
- Fully automated, processor-controlled monitoring system
- Compact design of center board and sub-stations
- Mixed operation mode of all switching modes within one electric circuit
- Free choice of power source (Battery, EPS, second mains power supply)
- Single luminaire monitoring for DC and AC networks
- Integrated freely selectable single luminaire or circuit monitoring
- A PC can be connected for free programming of all system and customer data
- Single-wire technology to sub distribution boards
- Highly secure thanks to intelligent sub-stations with sub-masters for autonomous operation mode
- Integrated test log for function tests and events over a period of more than 4 years
- Remote maintenance via phone or internet
- SD card for programming, display texts, test log, etc.
- Programming software included
type of protection: IP 21 Protection class: I
RZB LUXIFAIR is a series of modular systems that can be configured individually.
Available colour for housing and doors: RAL 7035 (light grey)
For more LUXIFAIR options: see page 148 et seqq.
EcM (electric circuit module)
IO module 24 for potential-free contacts
IO module 230 for direct mains voltage
Single control for single luminaire monitoring
DUO control for single luminaire monitoring and mixed operation mode
Message and switchboard
Printer for operating status messages and testing protocols
Central battery system (CPS)
LUXIFAIR
Additional LUXIFAIR options
Battery cabinet
page 124
Sub distribution boardpage 131
133
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
installation example
EIB
Sys
tem
Bus
Sec
ure
track
E30 fused junction box
E30 fused junction box
LUXIFAIR
circuit 1
circuit 2
circuit 3circuit 4
circuit 1
circuit 2
circuit 3
circuit 4
circuit 1
circuit 2
circuit 3
circuit 4
circuit 5
housing according to En 50272 and EltBau Vo
134
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
Similar to illustration
Similar to illustration
Similar to illustration
housing: plastic/metal
connection: plug-in terminals, directly on the module
Available for: surface mounting
Dimensions: L 385 x B 295 x t 110 mm
no. of EcMs: 1
no. of circuits: 4 circuits
Fire-protected: optional (additional cost)
Manufacturer: RZB
type: UV-SK1
housing: plastic/metal
connection: plug-in terminals, directly on the module
Available for: surface mounting
Dimensions: L 385 x B 295 x t 110 mm
no. of EcMs: 2
no. of circuits: 8 circuits
Fire-protected: optional (additional cost)
Manufacturer: RZB
type: UV-SK2
housing: plastic/metal
connection: plug-in terminals, directly on the module
Available for: surface mounting
Dimensions: L 800 x B 600 x t 250 mm
no. of EcMs: 3
no. of circuits: 12 circuits
Fire-protected: optional (additional cost)
Manufacturer: RZB
type: UV-SK3
LUXIFAIR sub distribution board UV-SK1 985288 L 385, B 295, t 110 mm
LUXIFAIR sub distribution board UV-SK2 985289 L 385, B 295, t 110 mm
LUXIFAIR sub distribution board UV-SK3 985290 L 800, B 600, t 250 mm
Sub distribution boards
LUXIFAIR
4
8
12
135
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
housing: plastic/metal
connection: plug-in terminals, directly on the module
Available for: surface mounting
Dimensions: L 800 x B 600 x t 250 mm
no. of EcMs: 4
no. of circuits: 16 circuits
Fire-protected: optional (additional cost)
Manufacturer: RZB
type: UV-SK4
housing: plastic/metal
connection: block terminals
Available for: surface mounting
Dimensions: L 800 x B 600 x t 250 mm
no. of EcMs: 5
no. of circuits: 20 circuits
Fire-protected: optional (additional cost)
Manufacturer: RZB
type: UV-SK5
housing: plastic/metal
connection: block terminals
Available for: surface mounting
Dimensions: L 800 x B 600 x t 250 mm
no. of EcMs: 6
no. of circuits: 24 circuits
Fire-protected: optional (additional cost)
Manufacturer: RZB
type: UV-SK6
Similar to illustration
Similar to illustration
Similar to illustration
LUXIFAIR sub distribution board UV-SK4 985291 L 800, B 600, t 250 mm
LUXIFAIR sub distribution board UV-SK5 985292 L 800, B 600, t 250 mm
LUXIFAIR sub distribution board UV-SK6 985293 L 800, B 600, t 250 mm
Version with IOM 230 or IOM 24 possible. Sub distribution boards can be configured to customer’s specific requirements.
Fire-protected version (E 30) available upon request.
Sub distribution boards
LUXIFAIR
24
20
16
136
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
Master
Microprocessor control and monitoring unit
the Master is a freely programmable control unit that also acts as the communication interface. the Master can be supported by further sub-masters, which form their own self-enclosed systems, but are always managed by the Master and communicate with each other via the Master bus or exchange switching commands that apply to both Master and sub-masters. Each master/sub-master forms its own communication bus, thus preventing communication overload on the overall system’s bus systems.
the Master unit provides all of the monitoring functions required by the applicable VDE and En standards and is equipped with the following features:
- Illuminated blue-design-display: 4 lines with 20 characters each
- Plain text display of all reports
- 6 membrane buttons for operating the unit
- Operating states reports via LED
- Buffer storage for reports and function tests dating back more than 4 years
- USB – interface for connecting a Pc
- SD card for programming, display texts, test log etc.
- 3 RS232 interfaces for expansion modules (print box, visualisation, phone line box, etc.)
- Remote maintenance via phone or internet
- Visualisation of the entire system on incorporated or existing Pc (option)
- 8 freely programmable digital inputs
- Windows-compatible embOS (embedded operating system)
- Programmable function keys for rapid access to frequently used functions
- Plain text display of local emergency modes
- Automatic search for specific luminaire addresses
- 8 programmable switching options per electric circuit
LUXIFAIR Master is the system‘s central intelligence. It performs all of the monitoring, log and test functions stipulated in En 50172 and En 50171 and stores them on an SD card.
the emergency lighting system can be programmed using the illuminated display or very conveniently using a laptop/Pc. LUXIFAIR Master, standard version, is equipped with a USB port.
As an option the Master can also be integrated into a safety lighting sub-station.
housing: plastic, grey
Display: 4 x 20 characters
type of installation: top hat rail
Operation: 6 function keys or Pc via USB
Special features: 8 freely programmable inputs
Ports: 1x USB, 3x RS232 via RJ45 jacks
Dimensions: h 90 x L 157 x B 61
Space requirements: 9 module spaces (MS)
LUXIFAIR
137
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
EC module installation example
Secure track
Note:
Mixed operation possible in each circuit.
138
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
- Fully automated, processor-controlled monitoring system
- Battery and electronic housings made of sheet steel: can be set up separately. Dimensions: 900 x 600 x 500 mm, each housing
- Mixed operation mode (DUO Control module required)
- Single changeover of each final circuit; freely programmable for maintained mode, non- maintained mode, switched maintained mode and staircase light circuit
- Integrated freely selectable single luminaire / circuit monitoring
- A PC can be connected for free programming of all system and customer data
- Potential-free outputs for message forwarding
- Single luminaire monitoring with plain text indication of target location
- Illuminated blue-design-display: 4 lines with 20 characters each, on the housing door
- Plain text display of all reports
- 6 membrane buttons for operating the unit
- Buffer storage for reports and function tests dating back more than 4 years
- USB interface for connecting a PC
- Direct connection to ECM (continuous conduction mode)
- Programming software included
type of protection: IP 21 Protection class: I
the LUXIFAIRlight central battery system contains all of the components stipulated in VDE 0108, part 100, VDE 0100, part 718, En 50171 and En 50272.
Available colour for housing and doors: RAL 7035 (light grey)
For more LUXIFAIRlight options: see page 148 et seqq.
EcM (electric circuit module)
Single control for single luminaire monitoring
DUO control for single luminaire monitoring and mixed operation
Message and switchboard
Printer for operating status messages and testing protocols
the LUXIFAIRlight electronics housing and battery cabinet can be set up separately and can be installed wall mounted. the battery can be stored in a battery cabinet or on a support. Battery cabinets: see page 124. Supports are available on request.
Please note: max. battery capacity: 100 Ah!
Batteries are not included in the price.
Central battery system (CPS)
LUXIFAIRlight
139
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
Battery cabinet and batteries are not included!
Larger battery cabinets are available on request.
installation example LUXIFAIRlight
circuit 1
circuit 2
circuit 3
circuit 4
housing in accordance with En 50272 and EltBauVO
Suitable battery cabinet, up to 45 Ah 900 x 600 x 500 985377
charging current EcM circuits LUXIFAIR Master Dimensions (mm) Article number
LUXIFAIRlight 4 max. 5 A 1 4 • 900 x 600 x 500 985366
LUXIFAIRlight 8 max. 5 A 2 8 • 900 x 600 x 500 985367
LUXIFAIRlight 12 max. 5 A 3 12 • 900 x 600 x 500 985368
LUXIFAIRlight 16 max. 5 A 4 16 • 900 x 600 x 500 985369
LUXIFAIRlight 20 max. 5 A 5 20 • 900 x 600 x 500 985370
LUXIFAIRlight 24 max. 5 A 6 24 • 900 x 600 x 500 985371
LUXIFAIRlight 28 max. 5 A 7 28 • 900 x 600 x 500 985372
LUXIFAIRlight 32 max. 5 A 8 32 • 900 x 600 x 500 985373
LUXIFAIRlight 36 max. 5 A 9 36 • 900 x 600 x 500 985374
LUXIFAIRlight 40 max. 5 A 10 40 • 900 x 600 x 500 985375
140
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
LUXIFAIRlight
Master
Microprocessor control and monitoring unit
the Master is a freely programmable control unit that also acts as the communication interface. the Master can be supported by further sub-masters, which form their own self-enclosed systems, but are always managed by the Master and communicate with each other via the Master bus or exchange switching commands that apply to both Master and sub-masters. Each master/sub-master forms its own communication bus, thus preventing communication overload on the overall system’s bus systems.
the Master unit provides all of the monitoring functions required by the applicable VDE and En standards and is equipped with the following features:
- Illuminated blue-design-display: 4 lines with 20 characters each
- Plain text display of all reports
- 6 membrane buttons for operating the unit
- Operating states reports via LED
- Buffer storage for reports and function tests dating back more than 4 years
- USB – interface for connecting a Pc
- SD card for programming, display texts, test log etc.
- 3 RS232 interfaces for expansion modules (print box, visualisation, phone line box, etc.)
- Remote maintenance via phone or internet
- Visualisation of the entire system on incorporated or existing Pc (optional)
- 8 freely programmable digital inputs
- Windows-compatible embOS (embedded operating system)
- Programmable function keys for rapid access to frequently used functions
- Plain text display of local emergency modes
- Automatic search for specific luminaire addresses
- 8 programmabl switching options per electric circuit
LUXIFAIR Master is the system‘s central intelligence. It performs all of the monitoring, log and test functions stipulated in En 50172 and En 50171 and stores them on an SD card.
the emergency lighting system can be programmed using the illuminated display or very conveniently using a laptop/Pc. LUXIFAIR Master, standard version, is equipped with a USB port.
As an option the Master can also be integrated into a safety lighting sub-station.
housing: plastic, grey
Display: 4 x 20 characters
type of installation: top hat rail
Operation: 6 function keys or Pc via USB
Special features: 8 freely programmable inputs
Ports: 1x USB, 3x RS232 via RJ45 jacks
Dimensions: h 90 x L 157 x B 61
Space requirements: 9 module spaces (MS)
141
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
Group battery systems (LPS) in comparison
type of system GV 1500 RZBeasy 202 RZBeasy 204
19” technology • – –
Modular technology • – –
tWIn technology,
mixed operation mode (maintained, non maintained, switchable mode) • • –
circuit monitoring • • •
Single luminaire monitoring
(without BUS wire)
with control 1 • – –
Switches
UE220i (for installation in luminaires) • • •
UE220e (for installation in distribution boards) • • •
number of circuits 4/8/12/16/20 2 4
Visualisation optional optional optional
network connection – optional optional
Voltage [V] Dc 230/216 V 230/220 V 230/220 V
DS = maintained | BS = non-maintained | GDS = switched maintained | TLS = staircase light circuit
142
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
- Fully automated, processor-controlled monitoring system
- 19” slide in rack
- Sheet steel cabinet with control panel cover
- Single changeover of each final circuit; freely programmable for maintained mode, non- maintained mode, switched maintained mode and staircase light circuit
- Integrated freely selectable single luminaire or circuit monitoring
- A PC can be connected free programming of all system and customer data
- Single luminaire monitoring with plain text indication of target location
- Twin housing with battery compartment
Group battery system (LPS)
RZB GV 1500
type of protection: IP 21 Protection class: I
the GV 1500 group battery system contains all of the components stipulated in VDE 0108 part 100, VDE 0100 part 718, En 50171, and En50272.
Available colour for housing and doors: RAL 7035 (light grey)
For more group battery system options: see page 148 et seqq.
Monitoring module cOntROL1 for installation in luminaires
UE220i switch for installation in luminaires
UE220e switch for installation in distributors
3-phase network monitoring module
tWIn technology
Message and switchboard
Printer for operating status messages and testing protocols
143
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
Batteries and connectors are not included.
TWIN control for group battery system (GV 1500)
three circuit modes (non-maintained, maintained and switched maintained) can be simultaneously switched and operated in mixed constellation in one single circuit, thus notably reducing the number of circuits.
tWIn control module for single luminaire monitoring, for installation in luminaires. Module for individually monitoring luminaires fitted with incandescent lamps, fluorescent lamps or LED with EB 2-120 W. Luminaire addresses are set using an externally accessible rotary code switch with integrated changeover switch.
TWIN Control for luminaire wattages of up to max. 500 W 985217
TWIN Control for luminaire wattages of up to max. 1500 W 985 218
Batteries for group battery system (GV 1500) - Sealed, rechargeable block batteries
- type: OGiV
- Designlife: 5 years at 20°c ambient temperature
- Extremely low gassing rate
- Low self-discharge
- 100% recyclable
- 18 batteries are needed
Batteries for group battery system (battery connector included)67000.0.152
type of system GV 1500/4 GV 1500/8 GV 1500/12 GV 1500/16 GV 1500/20
19” technology yes yes yes yes yes
„lightcontrol“ processor unit standard standard standard standard standard
no. of circuits 4 8 12 16 20
Freely programmable final circuit (maintai-ned, non-maintained, switched maintained mode and staircase light circuit)
yes yes yes yes yes
circuit monitoring standard standard standard standard standard
Single luminaire monitoring without bus line, with control 1 standard standard standard standard standard
tWIn control optional optional optional optional optional
Light switch setting sensor module optional optional optional optional optional
Wattage 1h 1500 W 1500 W 1500 W 1500 W 1500 W
Wattage 3h 500 W 500 W 500 W 500 W 500 W
Visualisation optional optional optional optional optional
Voltage 230/216 V 230/216 V 230/216 V 230/216 V 230/216 V
housing
Free-standing cabinet, twin
cabinet (1200 x 600 x 430)
Free-standing cabinet, twin
cabinet (1200 x 600 x 430)
Free-standing cabinet, twin
cabinet (1200 x 600 x 430)
Free-standing cabinet, twin
cabinet (1200 x 600 x 430)
Free-standing cabinet, twin
cabinet (1200 x 600 x 430)
catalogue number 985212 985213 985214 985215 985216
DS = maintained | BS = non-maintained | GDS = switched maintained | TLS = staircase light circuit
144
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
- Fully automated, processor-controlled monitoring system
- For decentralized power supply to safety luminaires within one fire compartment
- Sheet steel cabinet
- Single luminaire / circuit monitoring
- TWIN Control (mixed operation mode: maintained and non-maintained within one circuit (RZBeasy 202))
- Easy to set up
- Network connection (optional)
- Twin housing with battery compartment
type of protection: IP 21 Protection class: I
Available colour for housing and doors: RAL 7035 (light grey)
Group battery system (LPS)
RZBeasy 202 / 204 For more group battery system options: see page 148 et seqq.
3-phase network monitoring module
Message and switchboard
Electronic switch for dimming operation UE-DIM
Electronic switch with voltage control
tWIn technology
145
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
RZBeasy 202 / 204 installation example (Circuit monitoring)
circuit 1
RZBeasy
RZBeasy
RZBeasy
circuit 2
circuit 3
circuit 4
circuit 1
circuit 2
circuit 3
circuit 4
circuit 1
circuit 2
circuit 3
circuit 4
146
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
RZBeasy 202 / 204 calculation example
Battery included.
Total maximum wattage: 200 W !
type of system RZBeasy 202 RZBeasy 202 RZBeasy 204 RZBeasy 204
Rated operating time 1h 3h 1h 3h
Max. total wattage 200 W 200 W 200 W 200 W
Single luminaire control • • – –
tWIn control • • – –
circuit monitoring • • • •
no. of circuits 2 2 4 4
Max. no. of luminaires 32 32 80 80
Max. wattage per circuit 120 W 120 W 50 W 50 W
Min. wattage per circuit – – 15 W 15 W
Output voltage Ac/Dc 230 V / 220 V 230 V / 220 V 230 V / 220 V 230 V / 220 V
network of up to 25 pcs. optional optional optional optional
housing twin housing twin housing twin housing twin housing
Dimensions (822 x 414 x 220) (822 x 414 x 220) (822 x 414 x 220) (822 x 414 x 220)
catalogue number 985398 985399 985396 985397
RZBeasy 202 RZBeasy 204
P max. P max. P total
circuit 1 circuit 2 circuit 1 circuit 2 circuit 3 circuit 4
120 W 80 W 60 W 60 W 40 W 40 W 200 W
100 W 100 W 50 W 50 W 50 W 50 W 200 W
80 W 120 W 40 W 40 W 60 W 60 W 200 W
147
123
456
11121314
1516
3132333435363738
3940
4142
21 22 20 23 24 20 25 26 20 27 28 20
F21 F22 F23 F24 F25 F26 F27 F28
F2
F1
F3
F4
F29
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
RZBeasy 202 / 204 connecting diagramcircuit direction
Button LM test
LED LM test
Ec-Interface
Address input
Address
Mains mode signalMP
MP
12 VDc plus12 VDc minus
network monitoring 12 V nWc+nW
Battery mode signal
Message emergency mode disabled
Error message contact - no error
Error message contact - error
Module
Luminaire group 2Output 2a
n /
min
usL
/ pl
usea
rth
Output 2bn
/ m
inus
L /
plus
eart
h
Luminaire group 1Output 1a
Emergency lighting blocking - F
critical circuit / mains monitor
Maintained, group 1
PE (Mains connection)n (Mains connection)L (Mains connection)
Maintained, group 2
Maual control, non-maintained (BS)Fire detection system switch
Emergency lighting blocking - f
n /
min
usL
/ pl
usea
rth
Output 1b
n /
min
usL
/ pl
usea
rth
148
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
Accessories
type RZBbasic LUXIFAIR LUXIFAIRlight GV 1500 RZBeasy
3-phase network monitoring module • • • • •
Message and switchboard (surface mounting) • • • • •
Printer for operating status messages and testing protocols • • • • –
UE220i switch for installation in luminaires • • • • •
UE220e switch for installation in distributors • • • • •
Electronic switch for dimming operation • • • • •
Electronic switch with voltage control • • • • •
EcM (electric circuit module) – • • – –
IOM 24 for potential-free contacts – • – – –
IOM 230 for direct power supply voltage – • – – –
SInGLE cOntROL for single luminaire monitoring – • • – –
DUO cOntROL for single luminaire monitorin-gand mixed operation
– • • – –
Monitoring module cOntROL1 optional – – • –
tWIn technology – – – • •
Remote control tableau, type: MtB-BUS – – – • –
Universal changeover unit, type: UUE 4/220 / 4/220-80 – – – • –
Light switch setting sensor modules (LSM)
LSM 24 – – – • –
LSM 230 – – – • –
LSM 24/230 – – – • –
149
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
3-phase network monitoring module
3-phase network monitoring module for all systems 985147 L 59, B 35, h 59
type of protection: IP 20
Protection class: II
Input voltage: 230/400 V 50/60 hz
Own rating: < 4VA
Min. operating value: 85% of nominal voltage
contact set: 2 change-over relays, potential-free
Installation: c profile track
Display: LED OFF if power fails
Suiteable for installation in systems complying with DIn VDE 0108.
For installation in sub distribution boards for detecting undervoltage and power failures in single-phase or three-phase power systems. construction width: 35 mm.
Printer for RZBbasic, LUXIFAIR, LUXIFAIRlight and GV 1500 985138 L 100, B 100, h 50
Printer for operating status messages and testing protocols
VDE 0108 Part 100 stipulates that emergency lighting operated by central battery system must be function-tested every day of operation and the results be recorded in a protocol. Manual testing and recording in writing can be eliminated by implementation of an automatic testing facility with protocol printer.
All errors and system status changes are recorded with indication of date and time.
the elimination of the faults is indicated with date and time.
Message and switchboard (surface mounting) without battery
for RZBbasic and GV 1500 985256 L 70, B 54, h 135
for LUXIFAIR and LUXIFAIRlight 985364 L 70, B 54, h 135
for RZBeasy 202 / 204 985402 L 150, B 40, h 200
type of protection: IP 32
Protection class: II
In accordance with DIn VDE 0100 part 718
Displays: - Operational readiness of the system
- Battery mode
- collective error
Switches: maintained mode On/OFF
Installation: surface mounting
housing: plastic, grey
terminals: 1.5 mm2
Message and switchboard (surface mounting)
AccESSORIES FOR ALL cPS AnD LPS SyStEMS
B L
H
L
H
B
150
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
Electronic switch for luminaires with electronic ballasts (EB) and incandescent lamps in emergency lighting systems according to DIN VDE 0108
thanks to the UE220i switch, luminaires can be used both for general and for emergency lighting.
When voltage is present on the emergency power supply, the switch disconnects the luminaire from the general lighting power supply system. the time lag in switching eliminates any spark gaps in the changeover facility (relays), thus ensuring safe disconnection from the power supply.
UE220i is a switch for installation in luminaires; the relevant installation instructions must be followed.
Input voltage: General lighting power supply: 230 V Ac (+/- 10%)
Emergency power supply: 220 V Dc (+/- 20%)
Ambient temperature: -5 to +50 °c
changeover time: 100 ms
Switching power: 250 VA (short circuit proof 20 x Inom)
housing: plastic, black
Suiteable for installation in systems complying with DIn VDE 0108-100 En50172.
UE220i switch for all systems 981352.003 L 130, B 46, h 31
UE220e electronic switch for C and top hat rail (installation in distribution boards)
thanks to the UE220e switch, luminaires can be used simultaneously both for general and for emergency lighting. When voltage is present on the emergency power supply, the switch disconnects the luminaire from the general lighting power supply system.
Input voltage: General lighting power supply: 230 V Ac (+/- 10%)
Emergency power supply: 220 V Dc (+/- 20%)
Ambient temperature: -5 to +50 °c
changeover time: 100 ms
Switching power: 500 VA (short circuit proof 20 x Inom)
housing: plastic, grey
Suiteable for installation in systems complying with DIn VDE 0108-100 En50172.
UE 220e for all systems 981353.009 L 96, B 48, h 50
UE220i switch for installation in luminaires Installation example
UE220e switch for installation in distribution boards
Installation example UE220i (in luminaire)Please note:UE220e can only be installed in a distribution board.
Non-maintained circuit
Mains light switchGeneral lighting
Switching capacity:250VA
EB
Ue220i
LuminaireGroup batteryCentral battery
L+-
NNL+
-
NL
PF
Non-maintained circuit
Mains light switchGeneral lighting
Switching capacity:250VA
EB
Ue220i
LuminaireGroup batteryCentral battery
L+-
NNL+
-
NL
PF
Non-maintained circuit
Mains light switchGeneral lighting
Switching capacity:250VA
EB
Ue220i
LuminaireGroup batteryCentral battery
L+-
NNL+
-
NL
PF
AccESSORIES FOR ALL cPS AnD LPS SyStEMS
B
L
H
H
L
B
151
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
Switching module for operating dimmable, combined safety luminaires on mains and emergency power supplies
Version for:- Selective changeover from non-maintained to maintained power mode during mains operation, depending on the switching mode of the general lighting- Dimming luminaires in mains mode via a 1-10V interface- Dimming luminaires in emergency mode via integrated potentiometer
Control: - Switched phase on general lighting system
- 1-10V signal from lighting control
Input voltage: General lighting power supply: 230 V Ac (+/- 10%) Emergency power supply: 220 V Dc (+/- 20%)
Ambient temperature: -5 to +50 °c
changeover time: 100 ms
Switching power: 250 VA (short circuit proof 20 x Inom)
housing: plastic, grey
Suiteable for installation in systems complying with DIn VDE 0108-100 En50172.
UE-DIM for all systems 09-6230.000 L 175, B 42, h 32
Electronic switch for dimming operation
Switching module for operating dimmable, combined safety luminaires on mains and emergency power supplies
Version for:- Selective changeover from non-maintained to maintained power mode during mains operation, depending on the switching mode of the general lighting- Selective activation in emergency mode depending on the general lighting power supply
Control: - Switched phase on general lighting system
- non- switched phase on general lighting system
- codable function
Input voltage: General lighting power supply: 230 V Ac (+/- 10%)
Emergency power supply: 220 V Ac/Dc (+/- 20%)
Ambient temperature: -5 to +50 °c
changeover time: 100 ms
Switching power: 250 VA (short circuit proof 20 x Inom)
housing: plastic, black
Suiteable for installation in systems complying with DIn VDE 0108-100 En50172.
TW 200 for all systems 09-6202.009 L 130, B 45, h 32
Electronic switch with voltage control
Non-maintained circuit
Mains light switch
External light control for EB with 1-10 V control
Group batteryCentral battery
Switching capacity:250VA
EBUE-DIM
Luminaire
L+-
NNL+
-
NL
PF
1 2 3
Non-maintained circuit
External light control for EB with 1-10 V control
Group batteryCentral battery
Switching capacity:250VA
EB
SwitchTW 200
Luminaire
Network monitoring
General lightingMains light switch
L
+-
NNL+
-
NL
PF
L inactiv
activ
AccESSORIES FOR ALL cPS AnD LPS SyStEMS
B
L
H
H
L B
152
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
ECM (electric circuit module)
the Ec module is a bus-controlled electric circuit switching module. Fitted with a range of comfortable features, it offers both superior operational reliability and comprehensive monitoring technology. the safety or escape route luminaires are operated via the Ec module. All 4 output circuits on the module can be used both for circuit-monitored systems and for single luminaire monitoring.
Each module can operate 4 outgoing circuits with up to 20 luminaires each. Each outgoing circuit is protected by a 6.3 A (2-pole) fuse and can be switched individually. Max. voltage per electric circuit: 815 VA.
Each circuit of the lighting circuit assembly can be programmed in maintained power mode, non-maintained power mode, switched maintained power mode or mixed operation. the switching commands are transmitted via the mains power supply cable to the luminaire, without the need for an additional bus line. Single luminaire monitoring is also possible with the use of an nEA or secondary secured power supply as substitute source of power without the need for an additional test battery.
Each circuit can be switched via the IO-module. Status LEDs display the switching states of the outgoing circuits as well as the emergency mode. Error LEDs display fuse failures, luminaire malfunctions and overloads, thus facilitating troubleshooting considerably.
the information button offers the option of multiple error selection. the ES module is suitable for use in the base, in intelligent sub-stations or, as separate entity, for supplying individual fire compartments. It is connected to the master unit via the system bus.
ECM (electric circuit module)
Rating per circuit: 815 VA
Rating per module: 3260 VA
Fuse protection per circuit: 6.15 Ampere, 2-pole
connecting terminals: plug-in terminals, up to 1.5 mm²
circuit monitoring: standard
Addressing: 2 rotary code switches
Dimensions: L 157 x B 61 x h 90
Space requirement: 6 module spaces (MS)
type of installation: top hat rail
housing: plastic, grey
Secure track
max. 20 luminaires or 815 VA
Note:
Mixed operation possible in each circuit.
max. 20 luminaires or 815 VA
max. 20 luminaires or 815 VA
max. 20 luminaires or 815 VA
ECM installation example
ECM for LUXIFAIR and LUXIFAIRlight 985272 L 157, B 61, h 90
EIB System Bus
AccESSORIES FOR LUXIFAIR AnD LUXIFAIRlight
153
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
IO-Modul Light switch setting sensor modules
these modules allow for final circuit switching in mains mode using the switches or contactors of the mains power supply lighting.
the IO modules are suitable for installation in the base or sub-station. they are connected to the base via the 2-core system bus. the IO modules are programmed via the LUXIFAIR master unit.
IOM 24 for potential-free contacts
the input ports can interrogate a maximum of 16 circuits.
Each input can be assigned to one or several outgoing circuits. Requests are transmitted via potential-free contacts. Each input had a LED status display.
contacts: 16 x 24 V via external potential-free contacts
type of installation: top hat rail
connecting terminals: up to 1.5 mm²
Addressing: 2 rotary code switches
Dimensions: L 105 x B 61 X h 90
Space requirement: 6 module spaces (MS)
housing: plastic, grey
IOM 24 for LUXIFAIR 985273 L 105, B 61 , h 90
IOM 230 for direct power supply voltage
the input ports can interrogate a maximum of 9 circuits.
Each input can be assigned to one or several outgoing circuits. Requests are transmitted via 230 V Ac.
3 LEDs display the status of the power monitoring module. the master unit displays the power failure of the IO module with programmable plain text indication of location.
the IOM 230 can be configured with:
9 x 230 V Ac switch inputs or
6 x 230 V switch inputs + 3ph network monitoring module or
8 x 230 V switch inputs + 1ph network monitoring module
Each input has a LED status display.
type of installation: top hat rail
connecting terminals: up to 1.5 mm²
Addressing: 2 rotary code switches
Dimensions: L 105 x B 61 X h 90
Space requirement: 6 module spaces (MS)
housing: plastic, grey
IOM 230 for LUXIFAIR 985274 L 105, B 61, h 90
AccESSORIES FOR LUXIFAIR AnD LUXIFAIRlight
X1: 1 3 5 7 9 11 13 152 4 6 8 10 12 14 16E1 E2 E3 E4 E5 E6 E7 E8
Digitale Eingänge f.pot.-freie Kontakte
h 17 19 21 23 25 27 29 3118 20 22 24 26 28 30 32E9 E10 E11 E12E13E14E15E16
V
X1: 41 42 43 44
X1: 1n 1L 2n 2L 3n 3L 4n 4L 5n 5L 6n 6L
Digitale Eingänge für 230VAcKontaktbelegung n - L
X1: 41 42 43 44
E1 E2 E3 E4 E5 E6
E9 E8 E7 nL1 L2 L3
154
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
SINGLE Control for single luminaire monitoring
Module for monitoring single luminaires of 2-120 W. Luminaire addresses are set using an externally accessible rotary code switch.
type of protection: IP 20
Dimensions: L 81 x B 33 x h 24
Input voltage 230 V Ac (+ 10% / - 15%) 230 V Dc (+ 20% / - 20%)
housing: plastic, grey
Single Control for LUXIFAIR and LUXIFAIRlight 985280 L 81, B 33, h 24
DUO Control for single luminaire monitoring and mixed operation mode
Module for monitoring single luminaires of 2-120 W. the use of a DUO control module allows for mixed operation of maintained and non-maintained luminaires within the same circuit. Individual circuits can be switched using the inputs of the IO module. Luminaire addresses can be set manually using an externally accessible rotary code switch.
the DUO control module is also fitted with an invertible switch input.
type of protection: IP 20
Dimensions: L 81 x B 33 x h 24
Input voltage: 230 V Ac (+10% / -15%) 230 V Dc (+20% / -20%)housing: plastic, grey
Duo Control LUXIFAIR and LUXIFAIRlight 985279 L 81, B 33, h 24
LUXIFAIRCentral battery
Output circuits from central battery system
Outputmax. 120W SINGLE
Control
EB
Address allocation module is to be addressed!
Address Single +Tens1 = 0 +110 = 10 +111 = 10 +120 = 20 +0
++
2010
00
Address +20Address +10
2-6 W 8-120W
00
Output max.120 WN-
L+
N-
L+
SINGLE Controlfor EB and incandescent lamps 2-120 W
Please note:+ and - must not be reversed!
LUXIFAIRCentral battery
Output circuits from central battery system
Outputmax. 120W DUO
Control
EB
Address allocation module is to be addressed!
Address Single +Tens1 = 0 +110 = 10 +111 = 10 +120 = 20 +0
++
2010
00
Address +20
Address +10
2-6 W 8-120W
0
0
N-
L+
N-
L+
N-
L+
Network monitoring InputDS BS
DUO Controlfor EB and incandescent lamps 2-120 W
Please note:+ and - must not be reversed!
The following can be connected: Input
Single-phase network monitoring Network monitoring
The connected luminaire switches on in the event of a failure of the impressed phase
or
InputIf the general lighting switch is connected, the luminaire can be swithed via said genral lighting switch.
AccESSORIES FOR LUXIFAIR AnD LUXIFAIRlight
L
B
H
L
B
H
155
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
Monitoring module CONTROL1
type of protection: IP 20
Dimensions: L 106 x B 36 x h 24
Input voltage: 230 V Ac (+10% / -15%)
230 V Dc (+20% / -20%)
Ambient temperature: -5°c bis 50°c
housing: plastic, white
Module for monitoring single luminaires of 2-120 W. Luminaire addresses are set using an externally accessible rotary code switch.
CONTROL1 for RZBeasy and GV 1500 981348.002 L 106, B 36, h 24 mm
L/+
2-12 W
13-48 W
49-120 W
N/-
Inpu
t
EB
L/+
N/-
L/+ must always be connected
L/L+
N/N-
N/- depending on the performance of the luminaire or EB
Illustration below:
terminals L/L+ and n/n+ (mains side) are the connection to the emergency power unit; the poles must not be switched.
Illustration below:
control voltage for the internal switch
only is connected to terminals L and n.
terminals L/L+ and n/n+ (mains side) are the connection to the emergency power unit; the poles must not be switched.
TWIN technology
three power modes (non-maintained, maintained and switched maintained power mode) can be installed and operated within the same circuit, thus reducing the number of electric circuits.
Single luminaire monitoring module
tWIn control for installation in luminaires
Module for monitoring single luminaires of 2-120 W. Luminaire addresses are set using an externally accessible rotary code switch, with integrated changeover switch.
type of protection: IP 20
Dimensions: L 115 x B 34 x h 23
control voltage for changeover switch: 230 V Ac (+10% / -10%)
Input voltage: 230 V Ac (+10% / -15%) , 220 V Dc (+/- 20%)
Ambient temperature: -5 to + 50°c
housing: plastic, white
Suiteable for installation in systems complying with DIn VDE 0108-100 En50172. Radio interference suppression according to En55015.
TWIN-Control for RZBeasy and GV 1500 981705.002 L 115, B 34, h 23 mm
49-120W13-48W
2-12WL/+
N/-
EB
N/-
L/-
NL{
InputN/N-L/L+
An den Klemmen L und Nwird nur eine Steuerspannung
für die interne Umschaltweicheangelegt.
Die L/L+ und N/N- Klemmen(netzseitig) sind der Anschluss zur
Notstromanlage, die Polarität darf nicht vertauscht werden.
N/- depending on the performance of the luminaire or EB
L/+ must always be connected
AccESSORIES FOR GV 1500 AnD RZBeasy
H
B
L
H
L
B
156
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
Remote control tableau Type: MTB-BUS
- connection via 3-core bus line
- Surface mounted version with window in the housing
- Illuminated plain text display, 4 lines, 16 characters each
- Membrane keyboard
- Battery voltage display
- charging/discharging current display
- Voltage display of all 3 supply phases
- test log display
- Luminaire error display
- Error display in plain text
- Online
- Failure
- Mains supply mode / battery mode
- Maitained on / non-maintained on
- testing mode
- Switch system on/off
- Switch maintained light on/off
- Start of functions test and capacity test
- Selection of configuration and information menu
the remote control tableau can also be used as a display unit for sub-stations.
Remote control tableau for GV 1500 985021
Bus line 2 x 2 x 0,8
nyM 1 x 3 (for 220V Dc auxiliary voltage)
Universal changeover unit Type: UUE 4/220
All four output circuits of the plug-in units can be used both for circuit-monitored systems and for single luminaire monitoring. Mixed operation of single luminaire and circuit monitoring is also possible. the monitoring function can be subsequently modified from circuit to single luminaire monitoring at any time by means of simple re-configuration, without the need to exchange the hardware.
Each plug-in unit can operate 4 output circuits, with up to 16 luminaires each. Each output circuit is protected by a 6.3 A (1.25 A) (2-pole) fuse and can be switched individually. Each circuit in the lighting circuit assembly can be individually programmed.
the integrated staircase light switch mode allows for time-controlled switching in mains and emergency mode using the lighting power supply buttons (switch-on time 1 – 15 minutes, individually adjustable for each circuit.)
Universal changeover unit, type UUE 4/220 for GV 1500 985019
Universal changeover unit, type UUE 4/220-80 for up to 80 W total for GV 1500985195
AccESSORIES FOR GV 1500
157
EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS
tender texts available upon request | Specifications subject to alteration
Light switch setting sensor module (LSM)
this module allows for final circuit switching in mains mode using the switches or contactors of the mains power supply lighting. the input ports can interrogate a maximum of 16 circuits.
Each input can be programmed as a staircase light switch for time-controlled switching of emergency lighting (1-15 minutes).
Option:
the LSM modules can also be integrated in external distributors.
(Max. length of BUS line: 100 m).
Sensor module LSM 24
Each input can be assigned to one or several output circuits of a plug-in rack for single or group switching. Requests are transmitted via potential-free contacts.
Light switch setting sensor module LSM 24 for GV 1500 985054
Light switch setting sensor module LSM 230
Each input can be assigned to one or several output circuits of a plug-in rack for single or group switching. Requests are transmitted via an external 230 V Ac voltage.
Light switch setting sensor module LSM 230 for GV 1500 985055
Sensor module LSM 24 / 230
Each input can be assigned to one or several output circuits of a plug-in rack for single or group switching. Requests are transmitted via an external 230 V Ac voltage (8 inputs), as well as via potential-free contacts (8 inputs).
Light switch setting sensor module LSM 24/230 for GV 1500 985182
AccESSORIES FOR GV 1500
158
159
Luminaires for central emergency power supplyTenuo 160LED Halyxx® 162Ilustris 166Display 168Flat Sign Mini/Midi 170Design 172Rechteck 250 / 360 / 485 176Multivariabel 182Luminaires for sports facilities 184Standardleuchten 184Signcube 186Rechteck (Universal 2) 189Universal 3 190Universal 3 LED 191Universal 4 192Universal 4 LED 193LCS‑Z 194Varioplast I 196Turia 198Edo 200Lucio 202Centryxx 204Solyxx 206Energo TC 175 208Energo TC 210 210Andho TC Flat 212Andho TC Flat IP 65 214Arelo® 216Mondana 218Flat Polymero® 220Flat Polymero® PMMA/PC 222Flat Basic 224Flat Polymero® Rechteck 226Rounded® superflach 228Alu‑Lux oval 230Alu‑Rund 230Light Case 232Safety striplights 234Alu‑Druckguss 236Recessed LED step luminaire for installation in concrete steps 238
162, 164 162, 165 166
182 - 185 186 188, 189
172 - 174 176, 177172 - 174
216
188, 192 194 196
218
202 206204
176, 178
168
160 162 - 163
176, 179
170
198
188, 190 188, 192
208 - 210 212 - 214
200
228
236 238
230
234230
222
232
220
224 226
LED LED LED LED LED
LED
LED LED LED
LED
LED LED LED LED LED
LED LED
LED
160
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Motifs for escape route identification – Building and workplace legislation Legends in accordance with DIn 4844, UVV BgV A8 and EECR 92/58 Background colour: green
Tenuo Type of protection: IP 40
- The flattest existing emergency luminaire that incorporates the very latest energy saving LED technology
- Ultraflat - (panel 5 mm) frame 8 mm
- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
- Top quality LED technology
- Specially calculated thermal management
- The very latest LED technology keeps maintenance costs to a minimum
- LED service life: approx. 50,000 hours
- Exceptionally high luminance of over 900 cd/m2
- Wide range of applications thanks to various types of installation
wall extension wall (semi‑recessed) Ceiling (surface) Ceiling (recessed) Pendant tubeSuspension cable/chain
1003
1113
1114
1004
1115
1116
1005
161
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (surface) wall extension wall (semi‑recessed) wall (surface) Ceiling (recessed) Pendant tubeSuspension cable/chain
Installation scheme available on request
Installation scheme available on request
Installation scheme available on request
Installation scheme available on request
Installation scheme available on request
Installation scheme available on request
Installation scheme available on request
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671923.00X.y wall (surface) 30 m 1 x LED 2,5 w • • • • L 350, B 33, H 200
671938.00X.y wall extension 30 m 1 x LED 5 w • • • • L 400, B 60, H 200
671922.00X.y wall (semi‑recessed) 30 m 1 x LED 2,5 w • • • • L 350, B 11, H 200, LA 173, BA 173, TE 70
671939.00X.y Ceiling (surface) 30 m 1 x LED 5 w • • • • L 350, B 50, H 240
671940.00X.y Ceiling (recessed) 30 m 1 x LED 5 w • • • • L 420, B 40, H 252, LA 400, BA 40, HE 90
671941.00X.y Pendant tube 30 m 1 x LED 5 w • • • • L 350, B 50, H 200, LP 500
671942.00X.y Suspension cable/chain 30 m 1 x LED 5 w • • • • L 350, B 50, H 200, LP 500
Series: Tenuo
Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 30 m
For escape route identification
Housing: aluminium, silver Display panel with patented MicroLens technology.
LED included.
Please indicate symbol number when placing your order!
Ballast: EB
Available colour (X): 4 = aluminium, anodised
30 m30 m
H
L B
H
L B
HA
L TE
H
LA
B
H
L B
H
L
LAB
BA
HE
LP
L B
H
LP
L B
H
162
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
wall (surface) Ceiling (surface) Ceiling (recessed) wall (recessed)
Motifs for escape route identification – Building and workplace legislation Legends in accordance with DIn 4844, UVV BgV A8 and EECR 92/58 Background colour: green
LED Halyxx® Type of protection: IP 40
- High quality aluminium housing
- High quality and elegant design
- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
- Specially calculated thermal management
- The very latest LED technology keeps maintenance costs to a minimum
- LED service life: approx. 50,000 hours
- Luminance exceeds 500 cd/m2
- Wide range of applications thanks to various types of installation
- Moulded housing for concrete available
- Easy to install
1003
1113
1114
1004
1115
1116
1005
163
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Mounting set for suspension cable/chainViewing distance: 14 m981701.004 L 213, B 33, H 77 for art. 671504.004.y
Moulded housingViewing distance: 14 m981685.000 L 542, B 142, H 143 for art. 671519.004.y
Pendant setsViewing distance: 14 m981639.020 for .82981639.060 for .71/.81
Wall extensionViewing distance: 14 m981581.004 L 258, B 38, H 104 for art. 671504.004.y
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671503.00X.y wall (surface) 14 m 2 x LED 1,1 w • • • • L 233, B 40, H 180
671504.00X.y Ceiling (surface) 14 m 2 x LED 1,1 w • • • • L 233, B 40, H 180
671519.00X.y Ceiling (recessed) 14 m 2 x LED 1,1 w • • • • L 270, B 55, H 100 LA 255 x BA 42, HE 90
671547.12X.y wall (recessed) (cavity wall) 14 m 1 x LED 3,5 w ‑ ‑ ‑ ‑ L 220, B 150, H 2
LA 210 x BA 132, HE 90
671547.00X.y wall (recessed) (solid wall) 14 m 1 x LED 3,5 w ‑ ‑ ‑ ‑ L 220, B 150, H 2
LA 200 x BA 130, HE 80
Series: LED Halyxx®
Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 14 m Ceiling thickness: 5‑35 mm wall thickness: 1‑30 mm
For escape route identification
Base: aluminium extrusion profile; display panel: highly transparent plastic, with motifs on one side/both sides.
LED included.
Please specify legend number when ordering!
Ballast: EB
Available colour (X): 4 = aluminium, anodised
Accessories | Pendant set for ceiling luminairesSuspension length 500 mm (other lengths upon request), white plastic canopy, chrome suspension tube, length: 480 mm, can be shortened on site.
wall (surface) Ceiling (surface) Ceiling (recessed) wall (recessed) (cavity wall) wall (recessed) (solid wall)
14 m
H
L B
H
L B
H
LLA
BBA
HE5-
35
3
180
151233
4523Ø4,5
15
15
150233
Ø5
12,550
1640
4255
255270
HA
LHE
1-30
H
LA
BL
HA
HE
LA
B
H
132150
210220
130150
200220
164
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Ceiling (surface)wall (surface) Ceiling (recessed)
Mounting set for suspension cable/chainViewing distance: 19 m981701.004 L 213, B 33, H 77 for art. 671736.004.y
Moulded housingViewing distance: 19 m981686.000 L 542, B 142, H 143 for art. 671739.004.y
Pendant setsViewing distance: 19 m981639.020 for .82981639.060 for .71/.81
Wall extensionViewing distance: 19 m981581.004 L 258, B 38, H 104 for art. 671738.004.y
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671738.00X.y wall (surface) 19 m 2 x LED 1,1 w • • • • L 235, B 40, H 220
671736.00X.y Ceiling (surface) 19 m 2 x LED 1,1 w • • • • L 235, B 40, H 220
671739.00X.y Ceiling (recessed) 19 m 2 x LED 1,1 w • • • • L 320, B 55, H 140 LA 305 x BA 42, HE 90
For connecting diagrams, see pages 119 ‑ 121 | Article number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Series: LED Halyxx®
Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 19 m Ceiling thickness: 5‑35 mm
For escape route identification
Base: aluminium extrusion profile; display panel: highly transparent plastic, with motifs on one side/both sides.
LED included.
Please specify legend number when ordering!
Ballast: EB
Available colour (X): 4 = aluminium, anodised
Accessories | Pendant set for ceiling luminairesSuspension length 500 mm (other lengths upon request), white plastic canopy, chrome suspension tube, length: 480 mm, can be shortened on site.
19 m
H
L B
H
L B
H
L LA
B BA
HE
5-35
150
233Ø5
12,5
50
1640
3
220
151235
4523
Ø4,5
15
15
4255
305320
165
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (surface) Ceiling (surface) Ceiling (recessed)
Mounting set for suspension cable/chainViewing distance: 30 m981702.004 L 318, B 33, H 57 for art. 671737.004.y
Moulded housingViewing distance: 30 m981687.000 L 542, B 142, H 143 for art. 671740.004.y
Pendant setsViewing distance: 30 m981647.000 for .71/.81981647.020 for .82
Wall extensionViewing distance: 30 m981640.000 L 363, B 38, H 104 for art. 671722.004.y
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671722.00X.y wall (surface) 30 m 3 x LED 1,1 w • • • • L 340, B 40, H 270
671737.00X.y Ceiling (surface) 30 m 3 x LED 1,1 w • • • • L 340, B 40, H 270
671740.00X.y Ceiling (recessed) 30 m 3 x LED 1,1 w • • • • L 424, B 55, H 190 LA 410 x BA 42, HE 90
Series: LED Halyxx®
Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 30 m Ceiling thickness: 5‑35 mm
For escape route identification
Base: aluminium extrusion profile; display panel: highly transparent plastic, with motifs on one side/both sides.
LED included.
Please specify legend number when ordering!
Ballast: EB
Available colour (X): 4 = aluminium, anodised
Accessories | Pendant set for ceiling luminairesSuspension length 500 mm (other lengths upon request), white plastic canopy, chrome suspension tube, length: 480 mm, can be shortened on site.
H
L B
H
L B
H
L LA
B BA
HE
5-35
30 m
3
270
250340
4523
Ø4,5
15
25
40
270340
25
Ø510,5
27,5
4255
410424
166
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
wall (surface) Ceiling (surface)
Ilustris Type of protection: IP 20
- Design matches modern architectural styles
- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
- The very latest LED technology keeps maintenance costs to a minimum
- LED service life: approx. 50,000 hours
- Large viewing distance
- Wide range of applications thanks to various types of installation
167
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (surface) Ceiling (surface)
Pendant tube981777.0131 Pendant lenght 500 mm –981777.0231 Pendant length 500 mm for .82
Suspension cable/chain981776.000 Pendant lenght 1500 mm –
Wall extension981775.0031 L 300, B 150, H 35 –
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671843.00X.y wall (surface) 30 m 1 x LED 3 w ‑ ‑ ‑ • L 368, B 55, H 253
671847.00X.y Ceiling (surface) 30 m 1 x LED 3 w ‑ ‑ ‑ • L 368, B 27, H 263
Series: Ilustris
Type of protection: IP 20 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 30 m
For escape route identification
Housing: die‑cast aluminium, powder‑coated. 3 foils with escape route motif and 1 white foil included.
LED included.
Ballast: EB
Available colour (X): 31 = anthracite metallic 30 m
H
L B
H
L B
5,5x10
100368
26
Ø5,5
120
150
368
253
35 5522
168
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Ceiling (surface)wall (surface) Ceiling (recessed)
Motifs for escape route identification – Building and workplace legislation Legends in accordance with DIn 4844, UVV BgV A8 and EECR 92/58 Background colour: green
Display Type of protection: IP 40
- Absolutely uniform illumination of the motifs
- Wide range of applications thanks to various types of installation
- Designed for large viewing distances
- Standard fluorescent lamps can be used
- Specifically calculated reflector inside the luminaire
1003
1113
1114
1004
1115
1116
1005
169
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface)wall (surface) Ceiling (recessed)
Wall extension981489.002
Moulded housing981586.000
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671180.75X.y wall (surface) 32 m 1 x T16 (T5) 8 w • • • • L 332, B 70, H 236
671178.75X.y Ceiling (surface) 32 m 1 x T16 (T5) 8 w • • • • L 332, B 57, H 270
671179.75X.y Ceiling (recessed) 32 m 1 x T16 (T5) 8 w • • • • L 400, B 84, H 180 LA 380 x BA 68, HE 105
Series: Display
Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 32 m Ceiling thickness: 1‑40 mm
For escape route identification
Base: powder‑coated metal; plastic display panel wit motifs on one side/both sides. EB incorporated.
Lamp included.
Please specify legend number when ordering!
Ballast: EB
Available colours (X): 2 = white, 4 = silver metallic
Accessories | Wall extensionSteel bracket, white powder‑coated
Accessories | Pendant setSuspension tube, square: 40 x 40 mm, powder‑coated, suspension length 500 mm (other lengths available upon request)
Pendant kit90‑3757.002 Pendant length 500 mm white90‑3757.004 Pendant length 500 mm silver metallic
32 m
H
L B
H
L B
H
HE1-40
L
LA BA
B
5716
9618
332276
5x8
56
236
15
332
27643 18 5x8
84
400
68
380
170
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Pendant tubewall (surface)
Motifs for escape route identification – Building and workplace legislation Legends in accordance with DIn 4844, UVV BgV A8 and EECR 92/58 Background colour: green
Flat Sign Mini/Midi Type of protection: IP 43
- Exclusive luminaire design
- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
- Top quality LED technology
- Uniform light distribution provided by special LED arrangement
- 2 different housing dimensions for different viewing distances
1003
1113
1114
1004
1115
1116
1005
171
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Pendant tubewall (surface) Midiwall (surface) Mini
Article number Type of installation
Viewing distance
Type Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671555.00X.y wall (surface) 21 m Mini 2 x LED 1,1 w • ‑ • • L 237, B 84, H 125
671556.00X.y wall (surface) 32 m Midi 3 x LED 1,1 w • • • • L 348, B 84, H 178
671557.00X.y Pendant tube 21 m Mini 4 x LED 1,1 w • ‑ • • L 237, B 138, H 125, LP 480
671607.00X.y Pendant tube 32 m Midi 6 x LED 1,1 w • • • • L 348, B 138, H 178, LP 480
Series: Flat Sign Mini/Midi
Type of protection: IP 43 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 21 m, 32 m
For escape route identification
Housing: powder‑coated sheet steel; display panel: plastic, opal, with motifs on one side/both sides.
LED included.
Please specify legend number when ordering!
Ballast: EB
Available colour (X): 2 = white
21 m/32 m
LP
L B
H
H
L B
H
L B
60
10
Ø10
Ø3,530
237
27
348
Ø20
9x5178
120
27
237
Ø20
9x5125
8
172
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
wall extension Ceiling (surface) Pendant tubewall (surface), Ceiling (surface) wall (surface)
Motifs for escape route identification – Building and workplace legislation Legends in accordance with DIn 4844, UVV BgV A8 and EECR 92/58 Background colour: green
Design Type of protection: IP 40
- Flat aluminium housing in elegant design
- Installation-friendly design enables lamp replacement without tools
- Designed for large viewing distances
- Wide range of applications thanks to various types of installation
- Luminaire also available for escape route illumination
1003
1113
1114
1004
1115
1116
1005
173
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (surface) wall extension Pendant tubeCeiling (surface)
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671597.75X.y wall (surface) 26 m 1 x T16 (T5) 6 w • • • • L 294, B 55, H 190
671599.75X.y wall extension 26 m 1 x T16 (T5) 6 w • • • • L 314, B 55, H 190
671598.75X.y Ceiling (surface) 26 m 1 x T16 (T5) 6 w • • • • L 340, B 55, H 232
671600.75X.y Pendant tube 26 m 1 x T16 (T5) 6 w • • • • L 340, B 55, H 190, LP 524
Series: Design
Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 26 m
For escape route identification
Housing: aluminium, powder‑coated; plastic panel: opal, with motifs on one side/on two sides. EB incorporated.
Please indicate symbol number when placing your order!
Ballast: EB
Available colour (X): 2 = white
Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13
wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981167.002 L 380, B 295, H 185
26 m
H
L B
H
B L
90
15
210
294
190
27
19075
55
18
5,5x10
LP
H
L B
H190
L B
6 6340
8260
82Ø6
5542
52,5 52,5
340169,5
5x12
174
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Wire guard for wall luminaires981168.002 L 540, B 375, H 185
wall (surface) wall extension Pendant tubeCeiling (surface)
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671185.75X.y wall (surface) 33 m 1 x T16 (T5) 8 w • • • • L 370, B 55, H 228
671188.75X.y wall extension 33 m 1 x T16 (T5) 8 w • • • • L 390, B 55, H 228
671186.75X.y Ceiling (surface) 33 m 1 x T16 (T5) 8 w • • • • L 416, B 55, H 270
671312.75X.y Pendant tube 33 m 1 x T16 (T5) 8 w • • • • L 416, B 55, H 228, LP 500
For connecting diagrams, see pages 119 ‑ 121 | Article number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Series: Design
Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 33 m
For escape route identification
Housing: aluminium, powder‑coated; plastic panel: opal, with motifs on one side/on two sides. EB incorporated.
Please indicate symbol number when placing your order!
Ballast: EB
Available colour (X): 2 = white
Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13
wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.
33 m
H
L B
H
B L
LP
H
L B
H228
L B
117 22847
283
28370
6x16
22890
55
5x10
18
6 6416
8260
82Ø6
5542
53 53
416208
5x12
175
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Wire guard for wall luminaires981168.002 L 540, B 375, H 185
Spacing table 671181.752
Lamp luminous flux:
Mains: 450 lm, Emergency: 450 lm
The following values are indicated in m
h a b c d
2.5 8.4 3.5 10.6 4.6
3.0 8.7 3.8 11.8 4.9
3.5 9.7 3.9 12.6 5.1
4.0 10.0 4.0 13.5 5.3
Spacing table 671182.752
Lamp luminous flux:
Mains: 1350 lm, Emergency: 1350 lm
The following values are indicated in m
h a b c d
2.5 10.6 4.7 15.0 6.3
3.0 12.2 5.2 15.8 6.8
3.5 12.5 5.5 16.9 7.3
4.0 14.0 5.9 18.4 7.7
Spacing table 671183.752
Lamp luminous flux:
Mains: 3350 lm, Emergency: 3350 lm
The following values are indicated in m
h a b c d
2.5 13.2 5.8 18.0 8.0
3.0 14.4 6.5 20.4 8.8
3.5 15.9 7.0 21.9 9.4
4.0 16.9 7.5 22.4 10.0
Spacing table 671184.752
Lamp luminous flux:
Mains: 5400 lm, Emergency: 5400 lm
The following values are indicated in m
h a b c d
2.5 14.8 6.4 21.5 9.0
3.0 16.1 7.1 22.5 9.9
3.5 17.6 7.8 24.6 10.7
4.0 18.5 8.5 27.0 11.4
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671181.75X.y wall (surface), Ceiling (surface) ‑ 1 x T16 (T5) 8 w • • • • L 370, B 228, H 55
671182.75X.y wall (surface), Ceiling (surface) ‑ 1 x T26 (T8) 18 w • • • • L 695, B 228, H 55
671183.75X.y wall (surface), Ceiling (surface) ‑ 1 x T26 (T8) 36 w • • • • L 1305, B 228, H 55
671184.75X.y wall (surface), Ceiling (surface) ‑ 1 x T26 (T8) 58 w • • • • L 1605, B 228, H 55
Series: Design
Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Housing: aluminium, powder‑coated; plastic panel: transparent, prismatic inside; reflector: aluminium, highly polished anodised finish, wide beam. EB incorporated.
Ballast: LLB/EB
Available colour (X): 2 = white
Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13
wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.
wall (surface), Ceiling (surface) 8 w wall (surface), Ceiling (surface) 18 w wall (surface), Ceiling (surface) 36 w wall (surface), Ceiling (surface) 58 w
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
L B
H
L B
H
L B
H
L B
H
117 22864
4444
370
6x16
117 22864
317 4444
1305
6x16
117 22864
313 4444
1605
6x16
120 22852
615
35695
6x16
h
d c b
a
176
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Ceiling (surface) Suspension cable/chainPendant tubewall (surface) wall extension
Motifs for escape route identification – Building and workplace legislation Legends in accordance with DIn 4844, UVV BgV A8 and EECR 92/58 Background colour: green
Rechteck 250 / 360 / 485 Type of protection: IP 44
- High quality aluminium profile housing
- Installation-friendly conctruction facilitates easy lamp replacement
- Wide range of applications thanks to various types of installation
- Quick and easy to install thanks to the use of a quick-action locking mechanism for the lamp and ballast support
- Available also with exceptionally long service life and energy efficient LED technology
- LED conversion sets are available for existing luminaires
1003
1113
1114
1004
1115
1116
1005
177
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671207.00X.y wall (surface) 21 m 2 x LED 1,1 w • • • • L 250, B 90, H 140
671207.75X.y wall (surface) 21 m 1 x T16 (T5) 6 w • • • • L 250, B 90, H 140
671256.00X.y wall (surface) 21 m 2 x Co26 15 w ‑ ‑ ‑ ‑ L 250, B 90, H 140
671208.00X.y wall extension 21 m 4 x LED 1,1 w • • • • L 250, B 125, H 140
671209.75X.y wall extension 21 m 1 x T16 (T5) 6 w • • • • L 250, B 125, H 140
671258.00X.y wall extension 21 m 1 x E27 25 w ‑ ‑ ‑ ‑ L 250, B 125, H 140
671211.00X.y Ceiling (surface) 21 m 4 x LED 1,1 w • • • • L 250, B 125, H 140
671211.75X.y Ceiling (surface) 21 m 1 x T16 (T5) 6 w • • • • L 250, B 125, H 140
671260.00X.y Ceiling (surface) 21 m 1 x E27 25 w ‑ ‑ ‑ ‑ L 250, B 125, H 140
671213.00X.y Pendant tube 21 m 4 x LED 1,1 w • • • • L 250, B 125, H 140, LP 500
671213.75X.y Pendant tube 21 m 1 x T16 (T5) 6 w • • • • L 250, B 125, H 140, LP 500
671262.00X.y Pendant tube 21 m 1 x E27 25 w ‑ ‑ ‑ ‑ L 250, B 125, H 140, LP 500
671359.00X.y Suspension cable/chain 21 m 4 x LED 1,1 w • • • • L 250, B 125, H 140
671359.75X.y Suspension cable/chain 21 m 1 x T16 (T5) 6 w • • • • L 250, B 125, H 140
671357.00X.y Suspension cable/chain 21 m 1 x E27 25 w ‑ ‑ ‑ ‑ L 250, B 125, H 140
Ceiling (surface)wall (surface) Pendant tube Suspension cable/chainwall extension
Series: Rechteck 250
Type of protection: IP 44 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 21 m
For escape route identification
Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motif on one side/on both sides.
Lamp included.
Please specify legend number when ordering!
Ballast: EB
Available colours (X): 2 = white, 4 = aluminium, anodised
Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13
wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981167.002 L 380, B 295, H 185
21 m
H
40
BL
40 80
H
L B
LP
H
BL
40 40
40
H
L B
30
80
LB
4080
H
40
3340
140
250
6x1640
40
41
41
18140 80
12580
6x12 5555250
40 1212
80 68 12511
9
Ø 5 6x18 Ø 6
125
70 4x10
85250
60 125
250
50 5030
178
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Wire guard for wall luminaires981168.002 L 540, B 375, H 185
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671215.00X.y wall (surface) 32 m 3 x LED 1,1 w • • • • L 362, B 90, H 192
671215.75X.y wall (surface) 32 m 1 x T16 (T5) 8 w • • • • L 362, B 90, H 192
671264.00X.y wall (surface) 32 m 2 x IT‑3 30 25 w ‑ ‑ ‑ ‑ L 362, B 90, H 192
671217.00X.y wall extension 32 m 6 x LED 1,1 w • • • • L 362, B 125, H 192
671217.75X.y wall extension 32 m 1 x T16 (T5) 8 w • • • • L 362, B 125, H 192
671266.00X.y wall extension 32 m 2 x E27 25 w ‑ ‑ ‑ ‑ L 362, B 125, H 192
671223.00X.y Ceiling (surface) 32 m 6 x LED 1,1 w • • • • L 362, B 125, H 192
671223.75X.y Ceiling (surface) 32 m 1 x T16 (T5) 8 w • • • • L 362, B 125, H 192
671268.00X.y Ceiling (surface) 32 m 2 x E27 25 w ‑ ‑ ‑ ‑ L 362, B 125, H 192
671227.00X.y Pendant tube 32 m 6 x LED 1,1 w • • • • L 362, B 125, H 192, LP 500
671227.75X.y Pendant tube 32 m 1 x T16 (T5) 8 w • • • • L 362, B 125, H 192, LP 500
671270.00X.y Pendant tube 32 m 2 x E27 25 w ‑ ‑ ‑ ‑ L 362, B 125, H 192, LP 500
671363.00X.y Suspension cable/chain 32 m 6 x LED 1,1 w • • • • L 362, B 125, H 192
671363.75X.y Suspension cable/chain 32 m 1 x T16 (T5) 8 w • • • • L 362, B 125, H 192
671361.00X.y Suspension cable/chain 32 m 2 x E27 25 w ‑ ‑ ‑ ‑ L 362, B 125, H 192
wall (surface) Ceiling (surface) Pendant tube Suspension cable/chainwall extension
For connecting diagrams, see pages 119 ‑ 121 | Article number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Series: Rechteck 360
Type of protection: IP 44 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 32 m
For escape route identification
Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motif on one side/on both sides.
Lamp included.
Please specify legend number when ordering!
Ballast: EB
Available colours (X): 2 = white, 4 = aluminium, anodised
Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13
wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.
32 m
40
3340
192
362
6x1640
40
55
55
192
40
12
12
8068
125119
Ø 5
6x18
Ø 6
5555362
40 1212
80 68 12511
9
Ø 5 6x18 Ø 6
125
70 4x10
85362
60 125
362
50 5030
H
L B
H
40
BL
40 80
LP
H
BL
40 40
40
H
L B
30
40
LB
4080
H
179
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671229.00X.y wall (surface) 43 m 4 x LED 1,1 w • • • • L 485, B 90, H 250
671229.75X.y wall (surface) 43 m 1 x T26 (T8) 15 w • • • • L 485, B 90, H 250
671272.00X.y wall (surface) 43 m 2 x IT‑3 30 40 w ‑ ‑ ‑ ‑ L 485, B 90, H 250
671231.00X.y wall extension 43 m 8 x LED 1,1 w • • • • L 485, B 125, H 250
671231.75X.y wall extension 43 m 1 x T26 (T8) 15 w • • • • L 485, B 125, H 250
671274.00X.y wall extension 43 m 2 x E27 40 w ‑ ‑ ‑ ‑ L 485, B 125, H 250
671233.00X.y Ceiling (surface) 43 m 8 x LED 1,1 w • • • • L 485, B 125, H 250
671233.75X.y Ceiling (surface) 43 m 1 x T26 (T8) 15 w • • • • L 485, B 125, H 250
671276.00X.y Ceiling (surface) 43 m 2 x E27 40 w ‑ ‑ ‑ ‑ L 485, B 125, H 250
671235.00X.y Pendant tube 43 m 8 x LED 1,1 w • • • • L 485, B 125, H 250, LP 500
671235.75X.y Pendant tube 43 m 1 x T26 (T8) 15 w • • • • L 485, B 125, H 250, LP 500
671278.00X.y Pendant tube 43 m 2 x E27 40 w ‑ ‑ ‑ ‑ L 485, B 125, H 250, LP 500
671367.00X.y Suspension cable/chain 43 m 8 x LED 1,1 w • • • • L 485, B 125, H 250
671367.75X.y Suspension cable/chain 43 m 1 x T26 (T8) 15 w • • • • L 485, B 125, H 250
671365.00X.y Suspension cable/chain 43 m 2 x E27 40 w ‑ ‑ ‑ ‑ L 485, B 125, H 250
Ceiling (surface) Suspension cable/chainPendant tubewall (surface) wall extension
Series: Rechteck 485
Type of protection: IP 44 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 43 m
For escape route identification
Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motif on one side/on both sides.
Lamp included.
Please specify legend number when ordering!
Ballast: EB
Available colours (X): 2 = white, 4 = aluminium, anodised
43 m
H
40
BL
40 80
40
H
L B
30
LP
H
L B
40 40
H
L B
40
LB
4080
H
5555485
40 1212
80 68 12511
9
Ø 5 6x18 Ø 6
125
485
50 5030
125
4x10
4855050
70 85
60
40
3340
250
485
6x1640
40
55
55
250
40
12
12
8068
125119
Ø 5
6x18
Ø 6
180
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Sets for converting luminaires of series „Rechteck 250“ for LED lamps 981722.002 single sided 2 x LED 1,1 w981722.002.81 single sided 2 x LED 1,1 w981722.002.82 single sided 2 x LED 1,1 w981722.002.71 single sided 2 x LED 1,1 w981722.002.72 single sided 2 x LED 1,1 w981723.002 double sided 4 x LED 1,1 w981723.002.71 double sided 4 x LED 1,1 w981723.002.72 double sided 4 x LED 1,1 w981723.002.81 double sided 4 x LED 1,1 w981723.002.82 double sided 4 x LED 1,1 w
Sets for converting luminaires of series „Rechteck 360“ for LED lamps 981725.002 single sided 3 x LED 1,1 w981725.002.71 single sided 3 x LED 1,1 w981725.002.72 single sided 3 x LED 1,1 w981725.002.81 single sided 3 x LED 1,1 w981725.002.82 single sided 3 x LED 1,1 w981727.002 double sided 6 x LED 1,1 w981727.002.71 double sided 6 x LED 1,1 w981727.002.72 double sided 6 x LED 1,1 w981727.002.81 double sided 6 x LED 1,1 w981727.002.82 double sided 6 x LED 1,1 w
Sets for converting luminaires of series „Rechteck 485“ for LED lamps 981759.002 single sided 4 x LED 1,1 w981759.002.71 single sided 4 x LED 1,1 w981759.002.72 single sided 4 x LED 1,1 w981759.002.81 single sided 4 x LED 1,1 w981759.002.82 single sided 4 x LED 1,1 w981760.002 double sided 8 x LED 1,1 w981760.002.71 double sided 8 x LED 1,1 w981760.002.72 double sided 8 x LED 1,1 w981760.002.81 double sided 8 x LED 1,1 w981760.002.82 double sided 8 x LED 1,1 w
Accessories | Sets for converting luminaires for LED lampsProtection class: I Low‑cost conversion of rectangular luminaires with T16 6 w or common incandescent lamps into luminaires with energy‑efficient, long‑life LEDs. The conversion set can be clicked in any existing housing without needing to use any tool and can be connected to the existing power supply cable.Modules’ plate: powder‑coated aluminium sheet, ballasts and connecting terminal included.
you can start right now to convert existing emergency luminaires of series Rechteck 250, 360 and 485 from incandescent or fluorescent lamp versions to LED versions.
HOW?
It‘s quite simple and easy: just use our LED conversion kits for luminaires for central emergency power supply.
Very easy „press and clip“ mounting. The conversion kit can be inserted in any existing luminaire housing without needing any tool noR screws:
For connecting diagrams, see pages 119 ‑ 121 | Article number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
It’s so easy to save money
LED conversion kits
... press them together and ... ... click them into the luminaire housing.Just take the metal brackets ...
181
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
LED 4 w
33.29 €
T168 w
232.01 €
The correct arrangement of the LEDs was calculated by our photometry lab, which allows us to minimize the number of LEDs, without impairing the required luminance values laid down in DIn 4844, Part 1 (luminance of more than 500cd/m2 for the contrast colour).
Thanks to a clever heat management, we are able to drastically reduce heat stress fort he LEDs, preventing thus an early LED failure.
Average LED service life: approx. 50,000 hours!
Energy efficiency and costs
= costs for power supply
= costs for lamps
= lamp replacement costs
Costs comparison over a period of 5 years
Rechteck 360 in maintained mode (24h/day) LED Fluorescent lamp Incandescent lamp
Lamp wattage 4 w 8 w 2 x 25 w
Service life in hours 50,000 h 3,000 h 1,000 h
Total consumption in 1 year (8,760 h) in kwh 35.04 kwh 70.08 kwh 438.00 kwh
Power supply costs in 1 year (at 0.19 €/kwh) 6.66 € 13.32 € 83.22 €
Total consumption in 5 years (43,800 h) in kwh 175.20 kwh 350.40 kwh 2,190.00 kwh
Power supply costs in 5 years (at 0.19 €/kWh) 33.29 € 66.58 € 416.10 €
number of lamps needed in 5 years (43,800 h) 0 14 43
Costs for lamps in 5 years 0.00 € 107.10 € 118.68 €
Average time needed for replacing a lamp (minutes) 15 min. 10 min. 10 min.
Costs for replacing lamps (caretaker 25.00 €/h) 0.00 € 58.33 € 179.17 €
Total costs in 5 years (power supply, lamps, lamp replacement) 33.29 € 232.01 € 713.95 €
Incandescent lamps 2 x 25 w713.95 €
182
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
wall (surface), Ceiling (surface) Pendant tube
Spacing table 671373.752
Lamp luminous flux:
Mains: 300 lm, Emergency: 300 lm
The following values are indicated in m
h a b c d
2.5 5.7 2.4 8.4 3.1
3.0 6.3 2.3 8.2 3.1
3.5 5.9 2.2 7.7 2.9
4.0 6.5 1.9 8.0 2.6
Spacing table 671374.912
Lamp luminous flux:
Mains: 600 lm, Emergency: 600 lm
The following values are indicated in m
h a b c d
2.5 8.3 3.2 10.0 4.2
3.0 8.6 3.4 11.2 4.3
3.5 9.1 3.4 11.8 4.4
4.0 8.4 3.4 11.1 4.4
Spacing table 671376.752
Lamp luminous flux:
Mains: 450 lm, Emergency: 450 lm
The following values are indicated in m
h a b c d
2.5 7.2 2.9 9.3 3.8
3.0 7.9 2.9 10.2 3.8
3.5 7.4 2.9 9.7 3.8
4.0 7.2 2.8 10.6 3.6
Spacing table 671377.912
Lamp luminous flux:
Mains: 900 lm, Emergency: 900 lm
The following values are indicated in m
h a b c d
2.5 9.1 3.8 12.2 5.0
3.0 10.0 4.0 12.1 5.2
3.5 9.6 4.1 13.1 5.3
4.0 9.9 4.2 13.7 5.4
Multivariabel Type of protection: IP 54
- Industrial Design
- IP 54 type of protection - dustproof and protected against water spray
- Quick and easy to install thanks to the use of a quick-action locking mechanism for the lamp and ballast support
- Different types of installation for one sole luminaire
- Lamp replacement without tools
- Easy to install
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
h
d c b
a
183
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (surface), Ceiling (surface) Pendant tube
Wire guard for wall luminaires981167.002 L 380, B 295, H 185 for L 275981168.002 L 540, B 375, H 185 for L 370
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671374.91X.y wall (surface), Ceiling (surface) 22 m 1 x TC‑EL 9 w • • • • L 275, B 130, H 130
671377.91X.y wall (surface), Ceiling (surface) 22 m 1 x TC‑EL 11 w • • • • L 370, B 130, H 130
671373.75X.y wall (surface), Ceiling (surface) 22 m 1 x T16 (T5) 6 w • • • • L 275, B 130, H 130
671376.75X.y wall (surface), Ceiling (surface) 22 m 1 x T16 (T5) 8 w • • • • L 370, B 130, H 130
671372.00X.y wall (surface), Ceiling (surface) 22 m 2 x E14 25 w ‑ ‑ ‑ ‑ L 275, B 130, H 130
671375.00X.y wall (surface), Ceiling (surface) 22 m 2 x E14 25 w ‑ ‑ ‑ ‑ L 370, B 130, H 130
671380.91X.y Pendant tube 22 m 1 x TC‑EL 9 w • • • • L 275, B 130, H 130, LP 500
671383.91X.y Pendant tube 22 m 1 x TC‑EL 11 w • • • • L 370, B 130, H 130, LP 500
671379.75X.y Pendant tube 22 m 1 x T16 (T5) 6 w • • • • L 275, B 130, H 130, LP 500
671382.75X.y Pendant tube 22 m 1 x T16 (T5) 8 w • • • • L 370, B 130, H 130, LP 500
671378.00X.y Pendant tube 22 m 2 x E14 25 w ‑ ‑ ‑ ‑ L 275, B 130, H 130, LP 500
671381.00X.y Pendant tube 22 m 2 x E14 25 w ‑ ‑ ‑ ‑ L 370, B 130, H 130, LP 500
Series: Multivariabel
Type of protection: IP 54 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 22 m
For escape route identification or escape route illumination
Base: aluminium, powder‑coated. Canopy: white. Pendant tube: chrome. Diffuser: plastic, opal, 3 foils for escape route identification included.
Ballast: EB
Available colour (X): 2 = white
Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13
wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.
22 m
H
L B H
LP
L B
130
370
Ø6
40 4030 30
4520
50
80
4x14
184
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
wall (recessed) wall (surface), Ceiling (surface) Pendant tube
Spacing table 671236.912
Lamp luminous flux:
Mains: 600 lm, Emergency: 600 lm
The following values are indicated in m
h a b c d
2.5 7.5 3.2 10.1 4.2
3.0 8.6 3.4 11.2 4.4
3.5 8.7 3.4 11.5 4.4
4.0 8.5 3.3 11.2 4.4
Spacing table 671237.912
Lamp luminous flux:
Mains: 600 lm, Emergency: 600 lm
The following values are indicated in m
h a b c d
2.5 7.5 3.2 10.1 4.2
3.0 8.6 3.4 11.2 4.4
3.5 8.7 3.4 11.5 4.4
4.0 8.5 3.3 11.2 4.4
Luminaires for sports facilities Type of protection: IP 30
- Compact design
- Available also as ball impact proof version
- Different types of installation for one sole luminaire
- Installation-friendly construction
- Industrial design
- Easy lamp replacement
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
h
d c b
a
185
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (recessed) (solid wall) wall (surface), Ceiling (surface) wall (recessed) (cavity wall) Pendant tube
Article number Type of installation
Viewing distance
ball impact proof
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671308.00X.y wall (recessed) (cavity wall) 14 m ‑ 1 x E14,
IT‑2 20 25 w ‑ ‑ ‑ ‑ L 230, B 75, H 5 LA 220 x BA 66, HE 65
671286.00X.y wall (recessed) (solid wall) 14 m ‑ 1 x E14,
IT‑2 20 25 w ‑ ‑ ‑ ‑ L 230, B 75, H 5 LA 220 x BA 66, HE 65
671288.00X.y wall (recessed) (solid wall) 14 m • 1 x E14,
IT‑2 20 25 w ‑ ‑ ‑ ‑ L 230, B 75, H 5 LA 220 x BA 66, HE 65
671309.91X.y wall (recessed) (cavity wall) 14 m ‑ 1 x TC‑EL 9 w • ‑ • • L 230, B 75, H 5
LA 220 x BA 66, HE 65
671287.91X.y wall (recessed) (solid wall) 14 m ‑ 1 x TC‑EL 9 w • ‑ • • L 230, B 75, H 5
LA 220 x BA 66, HE 65
671289.91X.y wall (recessed) (solid wall) 14 m • 1 x TC‑EL 9 w • ‑ • • L 230, B 75, H 5
LA 220 x BA 66, HE 65
671283.00X.y wall (surface), Ceiling (surface) 14 m ‑ 1 x E14,
IT‑2 20 25 w ‑ ‑ ‑ ‑ L 230, B 75, H 76
671284.00X.y wall (surface), Ceiling (surface) 14 m ‑ 1 x E14,
IT‑2 20 25 w ‑ ‑ ‑ ‑ L 230, B 75, H 76
671236.91X.y wall (surface), Ceiling (surface) 14 m ‑ 1 x TC‑EL 9 w • ‑ • • L 230, B 75, H 76
671237.91X.y wall (surface), Ceiling (surface) 14 m • 1 x TC‑EL 9 w • ‑ • • L 230, B 75, H 76
671285.00X.y Pendant tube 14 m ‑ 1 x E14, IT‑2 20 25 w ‑ ‑ ‑ ‑ L 230, B 75, H 76, LP 500
671238.91X.y Pendant tube 14 m ‑ 1 x TC‑EL 9 w • ‑ • • L 230, B 75, H 76, LP 500
Series: Luminaires for sports facilities
Type of protection: IP 30 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 14 m
For escape route identification or escape route illumination
Base: galvanised sheet steel; diffuser: plastic, opal, 3 foils for escape route identification included. Version with TC‑EL‑Lp: EB incorporated
Ballast: EB
Available colour (X): 2 = white 14 m
B
HE
BA
L
LA
H
B
HE
BA
L
LA
H
H
L B
14
1466
31
65
75
230
220
max. 30
14
1466
31
65
75
90182
230
220
40
Ø575
183
23086
5x1520
LP
BL
H
75
230
60
186
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Signcube Type of protection: IP 40
- Motifs on four sides
- Plastic cube (PMMA)
- For large viewing distances
- Wide range of applications thanks to various types of installation
- Excellent light distribution on the cube‘s surface
- Suspension can be shortened on side
- Easy to install
- Available with high quality LED technology
wall (surface), Ceiling (surface) Pendant tube Suspension cable/chain
Special motifs in accordance with BgV A8
187
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (surface), Ceiling (surface) Pendant tube
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671601.00X.y wall (surface), Ceiling (surface) 24 m 8 x LED 1,1 w • • • • L 255, B 255, H 276
671601.92X.y wall (surface), Ceiling (surface) 24 m 1 x TC‑DEL 13 w • • • • L 255, B 255, H 276
671826.00X.y Pendant tube 24 m 8 x LED 1,1 w • • • • L 255, B 255, H 291, LP 510
671602.92X.y Pendant tube 24 m 1 x TC‑DEL 13 w • • • • L 255, B 255, H 291, LP 510
671822.00X.y Suspension cable/chain 24 m 8 x LED 1,1 w • • • • L 255, B 255, H 300
671612.92X.y Suspension cable/chain 24 m 1 x TC‑DEL 13 w • • • • L 255, B 255, H 300
Suspension cable/chain
Series: Signcube
Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 24 m
For escape route identification
Base: powder‑coated metal; canopy: plastic, white; pendant tube: metal, chrome (can be shortened on site); diffuser: plastic (PMMA), opal; 3 motif foils for escape route identification included (according to DIn 4844, UVV gBV A8 and EwgR 92/58), EB incorporated.
Ballast: EB
Available colour (X): 2 = white
Replacement foils991116 Motif foil 240 x 240 Motif 2003991117 Motif foil 240 x 240 Motif 2004991118 Motif foil 240 x 240 Motif 2005
Accessories | Legend foils in accordance with UVV BGV A8 and EECR 92/58Viewing distance 48 m
24 m
B
L
H
LP
L
Ø108
B
H
190
38
190
255
255
27
Ø4,5x9
60
10
Ø10
Ø3,530
B
L
H
110
38
107
255
255
28
2003 2004 2005
188
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
wall (surface) Rechteck (Universal 2)
Rechteck (Universal 2) Type of protection: IP 44
- All-plastic luminaire, shockproof
- Classic design
- Installation benefits in case of protection class II
- 3 foils for escape route identification included
- Low-cost installation
Universal 3 / Universal 4 Type of protection: IP 54
- All-plastic luminaire, shockproof
- IP 54 type of protection - dustproof and protected against water spray
- Can be used for all types of installation (with accessories)
- Low power consumption
- 3 foils for escape route identification included
- Low-cost installation
Universal 3 LED / Universal 4 LED Type of protection: IP 54
- All-plastic luminaire, shockproof
- IP 54 type of protection - dustproof and protected against water spray
- Can be used for all types of installation (with accessories)
- Reliable and long-lasting LED technology
- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
- LED service life: approx. 50,000 hours
- 3 foils for escape route identification included
- Low-cost installation
wall (surface), Ceiling (surface) Universal 3 / Universal 3 LED
wall (surface), Ceiling (surface) Universal 4 / Universal 4 LED
wall (surface) Universal 4 / Universal 4 LED
189
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (surface)
Spacing table 671253.00X
Lamp luminous flux:
Mains: 400 lm, Emergency: 400 lm
The following values are indicated in m
h a b c d
2.5 6.1 1.9 6.2 3.6
3.0 5.2 1.5 6.8 3.5
3.5 4.9 0.6 6.5 3.3
4.0 ‑ ‑ ‑ ‑
Spacing table 671254.91X
Lamp luminous flux:
Mains: 400 lm, Emergency: 400 lm
The following values are indicated in m
h a b c d
2.5 6.1 1.9 6.2 3.6
3.0 5.2 1.5 6.8 3.5
3.5 4.9 0.6 6.5 3.3
4.0 ‑ ‑ ‑ ‑
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671253.00X.y wall (surface) 19 m 1 x E27 25 w ‑ ‑ ‑ ‑ L 215, B 115, H 110
671254.91X.y wall (surface) 19 m 1 x TC‑EL 7 w ‑ ‑ ‑ ‑ L 215, B 115, H 110
Series: Rechteck (Universal 2)
Type of protection: IP 44 Protection class: II Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 19 m
For escape route identification or escape route illumination
Base: plastic. Diffuser: plastic, opal. 3 foils for escape route identification included. Integrated EB (where necessary).
Ballast: EB
Available colours (X): 2 = white, 3 = black
Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13
wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981167.002 L 380, B 295, H 185
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
19 m
H
B
L
25
25114
85 85
214
6x10
h
d c b
a
190
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Spacing table 671386.912
Lamp luminous flux:
Mains: 400 lm, Emergency: 400 lm
The following values are indicated in m
h a b c d
2.5 6.6 2.5 8.2 3.3
3.0 6.8 2.5 8.5 3.2
3.5 7.1 2.4 8.1 3.1
4.0 6.7 2.1 8.7 2.8
Spacing table 671387.912
Lamp luminous flux:
Mains: 600 lm, Emergency: 600 lm
The following values are indicated in m
h a b c d
2.5 7.6 3.3 9.7 3.9
3.0 8.0 3.1 9.6 4.0
3.5 7.8 3.1 10.1 3.9
4.0 8.3 3.0 11.0 3.8
Article number Type of installation
Luminous flux factor
Type Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671384.00X.y wall (surface), Ceiling (surface) 21 m high hood 1 x E27 60 w ‑ ‑ ‑ ‑ L 240, B 126, H 145
671387.92X.y wall (surface), Ceiling (surface) 21 m high hood 1 x TC‑DEL 10 w • • • • L 240, B 126, H 145
671386.91X.y wall (surface), Ceiling (surface) 21 m high hood 1 x TC‑EL 7 w • • • • L 240, B 126, H 145
For connecting diagrams, see pages 119 ‑ 121 | Article number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Series: Universal 3
Type of protection: IP 54 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 21 m
For escape route identification or escape route illumination
Base: plastic. Diffuser: plastic, opal. Foil with escape route motif included.
Ballast: EB
Available colour (X): 2 = white
Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13
wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981167.002 L 380, B 295, H 185
Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.
Pendant tube90‑4164.002 LP 500 mm
Accessories | Wall extensionSteel, white powder‑coated
Wall extension981144.002 L 251, B 131, H 60
wall (surface), Ceiling (surface) (high hood)
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
h
d c b
a
21 m
H
L B
13
13100
80 100240
70
126
5x11
191
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Article number Type of installation
Viewing distance
Type Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671775.00X.y wall (surface) 21 m flat hood 1 x LED 2,1 w • • • • L 240, B 126, H 78
671782.00X.y wall (surface), Ceiling (surface) 21 m high hood 1 x LED 2,1 w • • • • L 240, B 126, H 145
Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13
wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981167.002 L 380, B 295, H 185
Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.
Pendant tube90‑4164.002 LP 500 mm
Accessories | Wall extensionSteel, white powder‑coated
Wall extension981144.002 L 251, B 131, H 60
Series: Universal 3 LED
Type of protection: IP 54 Protection class: II Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 21 m
For escape route identification
Base: plastic. Diffuser: plastic, opal. Foil with escape route motif included.
LED included.
Ballast: EB
Available colour (X): 2 = white
wall (surface), Ceiling (surface) (high hood)
wall (surface), Ceiling (surface) (flat hood)
21 m
H
L B
H
L B
13
13100
80 100240
70
126
5x11
13
13100
80 100240
70
126
5x11
192
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Spacing table 671630.752
Lamp luminous flux:
Mains: 450 lm, Emergency: 450 lm
The following values are indicated in m
h a b c d
2.5 8.0 3.3 10.0 4.2
3.0 8.9 3.3 11.1 4.3
3.5 9.0 3.3 11.7 4.3
4.0 8.9 3.3 11.1 4.2
Spacing table 671629.752
Lamp luminous flux:
Mains: 450 lm, Emergency: 450 lm
The following values are indicated in m
h a b c d
2.5 8.7 3.8 10.8 4.3
3.0 9.0 4.0 10.7 4.4
3.5 10.2 4.0 11.2 4.5
4.0 10.1 4.0 11.8 4.4
Wire guard for wall luminaires981168.002 L 540, B 375, H 185
Article number Type of installation
Luminous flux factor
Type Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671629.75X.y wall (surface), Ceiling (surface) 25 m flat hood 1 x T16 (T5) 8 w • • • • L 344, B 144, H 78
671630.75X.y wall (surface), Ceiling (surface) 21 m high hood 1 x T16 (T5) 8 w • • • • L 344, B 144, H 148
For connecting diagrams, see pages 119 ‑ 121 | Article number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Series: Universal 4
Type of protection: IP 54 Protection class: II Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 21 m, 25 m
For escape route identification (only wall installation) or escape route illumination
Base: plastic (polycarbonate), diffuser: plastic (polycarbonate), opal, or refractor, plastic (polycarbonate) transparent, prismatic, motif foil included, EB incorporated.
Ballast: EB
Available colour (X): 2 = white
Mounting kit for chains/cable suspensions981583.002
Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.
Pendant tube90‑4164.002 LP 500 mm
Accessories | Wall extensionSteel bracket, white powder‑coated
Wall extension981485.002 L 374, B 147, H 75
Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13
wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.
wall (surface), Ceiling (surface) (high hood) opal
wall (surface), Ceiling (surface) (flat hood) transparent, prismatic
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
h
d c b
a
H
L B
H
BL
50
250
15 110148,5
344
112,5 144
5x11
50
250
15 110148,5
344
112,5 144
5x11
21 m/25 m
193
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Wire guard for wall luminaires981168.002 L 540, B 375, H 185
Article number Type of installation
Viewing distance
Type Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
Single‑Control
(.81)
Duo‑Control
(.82)
Dimensions
671793.00X.y wall (surface) 25 m flat hood 1 x LED 4,5 w • • • • L 344, B 144, H 78
671820.00X.y wall (surface), Ceiling (surface) 21 m high hood 1 x LED 4,5 w • • • • L 344, B 144, H 148
Mounting kit for chains/cable suspensions981583.002
Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.
Pendant tube90‑4164.002 LP 500 mm
Accessories | Wall extensionSteel bracket, white powder‑coated
Wall extension981485.002 L 374, B 147, H 75
Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13
wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.
Series: Universal 4 LED
Type of protection: IP 54 Protection class: II Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 21 m, 25 m
For escape route identification
Base: plastic (polycarbonate); diffuser: plastic (polycarbonate), opal, or refractor: plastic (polycarbonate) transparent, prismatic, motif foil included.
LED included.
Ballast: EB
Available colour (X): 2 = white
wall (surface), Ceiling (surface) (high hood) opal
wall (surface), Ceiling (surface) (flat hood) tranparent, prismatic
H
L B
H
BL
50
250
15 110148,5
344
112,5 144
5x11
50
250
15 110148,5
344
112,5 144
5x11
21 m/25 m
194
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
wall (surface), Ceiling (surface) wall (surface)
LCS-Z Type of protection: IP 40
- Extremely flat housing, architecturally attractive design
- Reflector inside
- Lamp replacement without tools
- Easy to install
- Large viewing distance
- Easy to install
195
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (surface) wall (surface)
Spacing table 671776.752
Lamp luminous flux:
Mains: 400 lm, Emergency: 400 lm
The following values are indicated in m
h a b c d
2.5 11.1 4.5 9.7 4.5
3.0 12.1 4.6 10.4 4.6
3.5 12.8 4.8 10.9 4.8
4.0 13.2 4.6 11.2 4.6
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671774.75X.y wall (surface) 35 m 1 x T16 (T5) 8 w • • • • L 398, B 62, H 202
671776.75X.y wall (surface), Ceiling (surface) ‑ 1 x T16 (T5) 8 w • • • • L 398, B 62, H 202
Series: LCS‑Z
Type of protection: IP 40 Protection class: II Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 35 m
For escape route identification (only wall installation) or escape route illumination
Base and reflector: plastic (polycarbonate); refractor: plastic (PMMA) transparent, 3 foils for escape route identification included.
Ballast: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
35 m
H
L B
H
L B
174202
250371
398
8016
18
Ø5
174202
250371
398
8016
18
Ø5
h
d c b
a
196
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
wall (surface), Ceiling (surface) wall (surface)
Varioplast I Type of protection: IP 54
- Ultraflat design
- IP 54 type of protection - dustproof and protected against water spray
- Installation-friendly construction: folding mounting plate with lampholder and ballast
- Shockproof verison
- Compact design
- Multi-purpose applications
197
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (surface) Ceiling (surface)
Article number Type of installation
Viewing distance
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671248.91X.y wall (surface) 24 m 1 x TC‑EL 11 w • • • • L 320, B 80, H 186
671291.75X.y wall (surface) 24 m 1 x T16 (T5) 6 w • • • • L 320, B 80, H 186
671247.91X.y wall (surface), Ceiling (surface) ‑ 1 x TC‑EL 11 w • • • • L 320, B 80, H 186
671290.75X.y wall (surface), Ceiling (surface) ‑ 1 x T16 (T5) 6 w • • • • L 320, B 80, H 186
Spacing table 671247.91X
Lamp luminous flux:
Mains: 900 lm, Emergency: 900 lm
The following values are indicated in m
h a b c d
2.5 10.8 4.6 13.0 5.4
3.0 11.9 4.9 13.8 5.8
3.5 12.9 5.2 14.5 6.0
4.0 13.5 5.4 14.3 6.2
Spacing table 671290.75X
Lamp luminous flux:
Mains: 300 lm, Emergency: 300 lm
The following values are indicated in m
h a b c d
2.5 7.5 3.2 8.7 3.6
3.0 8.2 3.3 9.5 3.7
3.5 8.8 3.4 10.2 3.7
4.0 8.7 3.4 9.5 3.7
Series: Varioplast I
Type of protection: IP 54 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 24 m
For escape route identification (only in case of wall installation) or escape route illumination
Base: plastic (polycarbonate); refractor: plastic (polycarbonate) transparent, prismatic, 3 foils for escape route identification included.
Ballast: EB
Available colours (X): 2 = white, 3 = black
Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13
wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.
Wire guard for wall luminaires981168.002 L 540, B 375, H 185
Accessories | Set of screws with special anti‑theft key90‑4013.002 white90‑4013.003 black
Accessories | Wire guard, varnished22125.002 L 314, B 180, H 49 white22125.003 L 314, B 180, H 49 black
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
24 m
H
B
L
H
B
L
6
27148
16
115
288320
15430
116 186
8016
5x8
6
27148
16
115
288320
15430
116 186
8016
5x8
h
d c b
a
198
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Ceiling (recessed)
Turia Z Type of protection: IP 30
- Wide luminaire spacing for escape route illumination
- Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology)
- Top quality LED technology
- Specially calculated thermal management
- Very low maintenance costs
- LED service life: approx. 50,000 hours
- Easy to install
- Compact design
- Inconspicuous design
- The self-contained module containing the battery can easily be installed and removed through the ceiling cutout
199
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (recessed)
Spacing table 671919.002
Lamp luminous flux:
Mains: 148 lm, Emergency: 148 lm
The following values are indicated in m
h a b c d
2.5 7.3 3.0 7.3 3.0
3.0 8.2 3.4 8.2 3.4
3.5 8.9 3.6 8.9 3.6
4.0 9.5 3.7 9.5 3.7
Step 1 Step 2
Step 3 Step 4
Article number Type of installation
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671919.00X.y Ceiling (recessed) 1 x LED 2 w • • • • D 50, H 2, DA 42, HE 45
Series: Turia Z
Type of protection: IP 30 Protection class: I with .y, II without .y Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 15‑35 mm
For escape route illumination
Housing: die‑cast aluminium: cover ring: plastic; EB in separate ballast box with connection cable.
LED included.
Ballast: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
HDAD
HE
Ø50 Ø42
h
d c b
a
200
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Example
Edo Type of protection: IP 20
- Wide luminaire spacing for escape route illumination
- Energy efficient (consumption approx. 80% less than 13 W fluorescent lamp technology)
- Top quality LED technology
- Specially calculated thermal management
- Very low maintenance costs
- LED service life: approx. 50,000 hours
- Easy to install
- Compact design
- Inconspicuous design
Edo 1 Installation in existing luminiares
Edo 2 Installation in metal ceilings
Edo 4 Edo 5
+
+
=
201
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Edo 1 Retrofitting kit Edo 2 Retrofitting kit Ceiling (recessed) Edo 4 Ceiling (recessed) Edo 5
Accessories | Fixing bracket for Edo 1Bracket for fixing Edo 1 into recessed luminiares such as downlights or louvre luminaires. Bracket is to be installed in existing reflector or louvre.
Fixing bracket for Edo 1981778.000
Spacing table 671950.00X
Lamp luminous flux:
Mains: 109 lm, Emergency: 109 lm
The following values are indicated in m
h a b c d
2.5 7.7 3.0 7.7 3.0
3.0 8.5 3.2 8.5 3.2
3.5 8.9 3.2 8.9 3.2
4.0 9.1 3.2 9.1 3.2
Edo 1
Edo 2
Article number Type of installation
Type Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671950.00X.y Retrofitting kit Edo 1 1 x LED 2 w • • • • D 22, H 8, DA 10.5, HE 15
671951.00X.y Installation in metal ceilings Edo 2 1 x LED 2 w • • • • D 27, H 1, DA 22, HE 23
671936.00X Ceiling (recessed) Edo 4 1 x LED 2 w • • • • D 50, H 3, DA 40, HE 45
671937.00X Ceiling (recessed) Edo 5 1 x LED 2 w • • • • L 50, B 50, H 3, DA 40, HE 45
Series: Edo
Type of protection: IP 30 Protection class: I with .y, II without .y Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 1‑8 mm (Edo 1 and Edo 2) Ceiling thickness: 15‑35 mm (Edo 4 and Edo 5)
For escape route illumination
Housing: die‑cast aluminium; cover ring: plastic (only Edo 4 + 5), separate ballast box with connecting cable.
LED included.
Ballast: EB
Available colour (X): 2 = white (Edo 4 and Edo 5) 4 = aluminium (Edo 1 and Edo 2)
Table applies to all Edo series luminaires
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
H
DA
HE
D
DA
D
H
HE
HDAD
HE
Ø50 Ø40 Ø50 Ø40
HBAB
HE
LA L
h
d c b
a
202
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Ceiling (surface) Ceiling (recessed)
Lucio Type of protection: IP 40
- Wide luminaire spacing for escape route illumination
- Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology)
- Top quality LED technology
- Specially calculated thermal management
- Very low maintenance costs
- LED service life: approx. 50,000 hours
- Compact design
- Easy to install
- Multi-purpose applications, either as recessed or surface mounted ceiling luminaire
203
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface) Ceiling (recessed)
Spacing table 671916.002
Lamp luminous flux:
Mains: 56 lm, Emergency: 56 lm
The following values are indicated in m
h a b c d
2.5 5.2 2.1 5.2 2.1
3.0 5.7 2.0 5.7 2.0
3.5 6.0 1.7 6.0 1.7
4.0 5.9 1.0 5.9 1.0
Article number Type of installation
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671916.00X.y Ceiling (surface), Ceiling (recessed) 1 x LED 3 w ‑ ‑ ‑ ‑
Surface installation: D 120, H 45
Recessed installation: D 120, H 3, DA 105, HE 42
Series: Lucio
Type of protection: IP 40 Protection class: II Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 5‑25 mm
For escape route illumination
Housing: plastic. Accessories for recessed and surface ceiling installation included.
LED included.
Ballast: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
H
D
104
HDAD
HE
51
25(78)
Ø4,2
Ø16
Ø12059
73,5Ø4,2
Ø120 Ø105
h
d c b
a
204
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Centryxx Type of protection: IP 40
- Wide luminaire spacing for escape route illumination
- Design matches modern architectural styles
- Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology)
- Top quality LED technology
- Specially calculated thermal management
- Very low maintenance costs
- LED service life: approx. 50,000 hours
- Easy to install
Ceiling (recessed), squareCeiling (surface) Ceiling (recessed), round
205
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Spacing table 671841.002
Lamp luminous flux:
Mains: 180 lm, Emergency: 180 lm
The following values are indicated in m
h a b c d
2.5 3.4 0.9 12.6 5.6
3.0 3.0 0.8 14.2 6.4
3.5 2.6 0.7 16.1 7.1
4.0 2.4 0.0 10.5 0.0
Article number Type of installation
Type Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671841.00X.y Ceiling (surface) square 1 x LED 3 w ‑ ‑ ‑ • L 180, B 180, H 27
671839.00X.y Ceiling (recessed) square 1 x LED 3 w ‑ ‑ ‑ • L 220, B 220, H 3 DA 185, HE 73
671837.00X.y Ceiling (recessed) round 1 x LED 3 w ‑ ‑ ‑ • D 200, H 3 DA 185, HE 73
Series: Centryxx
Type of protection: IP 20 (wall (surface)), IP 40 (Ceiling (recessed)) Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Housing: die‑cast aluminium, powder‑coated; transparent plastic diffuser for optimum illumination of escape route.
Ballast: EB
Available colour (X): 2 = white
Ceiling (recessed), square Ceiling (recessed), roundCeiling (surface)
Table applies to all Centryxx series luminaires
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
HDAL
HE
B
HDAD
HE
B
L H
Ø200 Ø185 Ø200 Ø185
Ø5
180
90180
90
51
Ø5
h
d c b
a
206
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Ceiling (surface) Ceiling (recessed)
Solyxx Type of protection: IP 20
- Wide luminaire spacing for escape route illumination
- Subdued design
- Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology)
- Top quality LED technology
- Specially calculated thermal management
- Very low maintenance costs
- LED service life: approx. 50,000 hours
- Easy to install
207
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface) Ceiling (recessed)
Spacing table 671854.002 und 671835.002
Lamp luminous flux:
Mains: 178 lm, Emergency: 178 lm
The following values are indicated in m
h a b c d
2.5 8.6 3.7 5.2 2.1
3.0 9.6 3.9 5.6 2.1
3.5 10.5 4.3 5.9 2.1
4.0 11.2 4.6 6.2 2.2
Article number Type of installation
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671854.00X.y Ceiling (surface) 1 x LED 3 w ‑ ‑ • ‑ L 118, B 118, H 58
671835.00X.y Ceiling (recessed) 1 x LED 3 w ‑ ‑ • • L 120, B 120, H 5 LA 108 x BA 108, HE 80
Series: Solyxx
Type of protection: IP 20 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 1‑25 mm
For escape route illumination
Housing and anti‑glare shield: aluminium, white; for surface installation: white plastic housing; plastic diffuser: prismatic.
Ballast: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
L
B
H
Ø6
93118
18
70 25 94 118
15
108120
108120
HBAB
HE
LA L
h
d c b
a
208
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Ceiling (recessed)
Energo TC 175 Type of protection: IP 23
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Housing made of top quality die-cast aluminium
- Wide luminaire spacing for escape route illumination
- Modern design
- Bezel ring made of die-cast aluminium
- Infinitely adjustable spring fastening system
- EBs in separate ballast box
- Modular recessed luminaire with small recessed depth
- Easy to install
- For ceiling thicknesses of 1-40 mm
209
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (recessed)
Spacing table 671877.92X und 671879.92X
Lamp luminous flux:
Mains: 900 lm, Emergency: 900 lm
The following values are indicated in m
h a b c d
2.5 7.7 2.8 7.7 2.8
3.0 8.1 2.9 8.1 2.9
3.5 8.4 2.8 8.4 2.8
4.0 8.3 2.7 8.3 2.7
Spacing table 671878.96X und 671880.96X
Lamp luminous flux:
Mains: 1200 lm, Emergency: 1200 lm
The following values are indicated in m
h a b c d
2.5 7.5 2.9 7.5 2.9
3.0 8.1 3.1 8.1 3.1
3.5 8.5 3.0 8.5 3.0
4.0 8.7 3.0 8.7 3.0
Article number Type of installation
Lamps Mains/
Emergency
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671877.92X.y Ceiling (recessed) 1 / 1 1 x TC‑DEL 13 w • • • • D 188, H 4, DA 175, HE 100
671879.92X.y Ceiling (recessed) 2 / 1 2 x TC‑DEL 13 w • • • • D 188, H 4, DA 175, HE 100
671878.96X.y Ceiling (recessed) 1 / 1 1 x TC‑DEL 18 w • • • • D 188, H 4, DA 175, HE 100
671880.96X.y Ceiling (recessed) 2 / 1 2 x TC‑DEL 18 w • • • • D 188, H 4, DA 175, HE 100
Series: Energo TC 175
Type of protection: IP 23 with bezel ring without safety glass, IP 44 with bezel ring including safety glass Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 1‑40 mm
For escape route illumination
Modular design: A bezel ring must always be ordered for each basic luminaire!
Recess and bezel ring: die‑cast aluminium, bezel ring with bayonet fixing; bracket: galvanised sheet steel; reflector: alumi‑nium, highly polished anodised finish; ceiling installation with spring system. EB in separate ballast box with connecting cable L 400 mm in flexible hose, 5‑pole double terminal for through‑wiring.
Ballast: EB
Available colour (X) Basic luminaire: 4 = silver metallic
Moulded housing981656.000 Moulded housing L 500, B 250, H 160 mm
Panel mounting frame98102.002/176 Panel mounting frame Dimensions 285 x 285 mm
Bezel rings with safety glass, D 194 mm, H 9 mm 981653.002 Safety glass, transparent981653.004 Safety glass, transparent
Bezel rings without safety glass, D 194 mm, H 9 mm981653.102981653.104
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
Ø188 Ø175
HDAD
HE
h
d c b
a
210
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Ceiling (recessed)
Energo TC 210 Type of protection: IP 23
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Housing made of top quality die-cast aluminium
- Wide luminaire spacing for escape route illumination
- Modern design
- Bezel ring made of die-cast aluminium
- Infinitely adjustable spring fastening system
- EBs in separate ballast box
- Modular recessed luminaire with small recessed depth
- Easy to install
- For ceiling thicknesses of 1-40 mm
211
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (recessed)
Spacing table 671883.83X und 671884.83X
Lamp luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
h a b c d
2.5 9.4 3.8 9.4 3.8
3.0 10.3 4.1 10.3 4.1
3.5 11.0 4.1 11.0 4.1
4.0 11.5 4.1 11.5 4.1
Article number Type of installation
Lamps Mains/
Emergency
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671883.83X.y Ceiling (recessed) 1 / 1 1 x TC‑TEL 32 w • • • • D 220, H 4, DA 210, HE 120
671884.83X.y Ceiling (recessed) 2 / 1 2 x TC‑TEL 32 w • • • • D 220, H 4, DA 210, HE 120
Series: Energo TC 210
Type of protection: IP 23 with bezel ring without safety glass, IP 44 with bezel ring including safety glass Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 1‑40 mm
For escape route illumination
Modular design: A bezel ring must always be ordered for each basic luminaire!
Recess and bezel ring: die‑cast aluminium, bezel ring with bayonet fixing; bracket: galvanised sheet steel; reflector: alumi‑nium, highly polished anodised finish; ceiling installation with spring system. EB in separate ballast box with connecting cable L 400 mm in flexible hose, 5‑pole double terminal for through‑wiring.
Ballast: EB
Available colour (X) Basic luminaire: 4 = silver metallic
Moulded housing981662.000 Moulded housing L 450, B 300, H 200 mm
Panel mounting frame98102.002/215 Panel mounting frame Dimensions 285 x 285 mm
Bezel rings with decorative attachment, D 250 mm, H 38 mm 981660.002 Decorative glass, transparent981660.004 Decorative glass, transparent
Bezel rings with safety glass, D 227 mm, H 9 mm 981659.002 Safety glass, transparent981659.004 Safety glass, transparent
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
Ø220 Ø210
HDAD
HE
h
d c b
a
212
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Ceiling (surface)
Andho TC Flat Type of protection: IP 23
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Design matches modern architectural styles
- Housing made of top quality die-cast aluminium
- Top quality reflector made of aluminium, highly polished anodised finish
213
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface)
Accessories981678.002 Suspension cable (2m) with 5‑pole power supply cable (IP 23)981678.004 Suspension cable (2m) with 5‑pole power supply cable (IP 23)
Spacing table 671886.84X
Luminaire luminous flux:
Mains: 2400 lm, Emergency: 2400 lm
The following values are indicated in m
h a b c d
2.5 10.5 4.7 10.2 4.5
3.0 12.7 5.6 12.3 5.4
3.5 14.8 6.3 14.2 6.0
4.0 16.1 6.9 15.4 6.4
Spacing table 671885.82X
Luminaire luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
h a b c d
2.5 10.5 4.7 10.2 4.5
3.0 12.7 5.4 12.2 5.2
3.5 14.1 5.8 13.4 5.6
4.0 15.2 6.4 14.4 6.1
Spacing table 671887.83X
Luminaire luminous flux:
Mains: 3600 lm, Emergency: 3600 lm
The following values are indicated in m
h a b c d
2.5 10.5 4.7 10.2 4.5
3.0 12.7 5.6 12.3 5.4
3.5 14.8 6.5 14.3 6.3
4.0 16.9 7.5 16.4 7.2
Article number Type of installation
Lamps Mains/
Emergency
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671885.82X.y Ceiling (surface) 2 / 2 2 x TC‑TEL 13 w • • • • D 230, H 140
671886.84X.y Ceiling (surface) 2 / 2 2 x TC‑TEL 18 w • • • • D 230, H 140
671887.83X.y Ceiling (surface) 2 / 2 2 x TC‑TEL 26 w • • • • D 230, H 140
Series: Andho TC Flat
Type of protection: IP 23 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Housing: aluminium extrusion profile, powder‑coated; cover ring and ceiling base: die‑cast aluminium, powder‑coated, with bayonet fixing; reflector: aluminium, highly polished anodised finish; EB incorporated, 5‑pole double terminal for through‑wiring.
Ballast: EB
Available colours (X): 2 = white, 4 = silver metallic
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
H
D
178
45178
Ø230
Ø7
h
d c b
a
214
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Ceiling (surface)
Andho TC Flat IP 65 Type of protection: IP 65
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Design matches modern architectural styles
- Housing made of top quality die-cast aluminium
- Top quality reflector made of aluminium, highly polished anodised finish
215
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (surface)
Accessories981678.002 Suspension cable (2m) with 5‑pole power supply cable (IP 23)981678.004 Suspension cable (2m) with 5‑pole power supply cable (IP 23)
Spacing table 671888.82X
Luminaire luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
h a b c d
2.5 9.9 4.5 9.4 4.1
3.0 11.6 4.9 11.0 4.8
3.5 12.7 5.3 12.1 5.1
4.0 13.8 5.9 13.2 5.7
Spacing table 671889.84X
Luminaire luminous flux:
Mains: 2400 lm, Emergency: 2400 lm
The following values are indicated in m
h a b c d
2.5 9.9 4.5 9.4 4.1
3.0 11.9 5.2 11.3 4.9
3.5 13.5 5.8 12.8 5.6
4.0 14.6 6.4 13.8 5.9
Spacing table 671890.83X
Luminaire luminous flux:
Mains: 3600 lm, Emergency: 3600 lm
The following values are indicated in m
h a b c d
2.5 9.9 4.5 9.4 4.1
3.0 11.9 5.4 11.3 4.9
3.5 13.9 6.3 13.2 5.8
4.0 15.8 6.6 15.0 6.4
Article number Type of installation
Lamps Mains/
Emergency
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671888.82X.y Ceiling (surface) 2 / 2 2 x TC‑TEL 13 w • • • • D 230, H 148
671889.84X.y Ceiling (surface) 2 / 2 2 x TC‑TEL 18 w • • • • D 230, H 148
671890.83X.y Ceiling (surface) 2 / 2 2 x TC‑TEL 26 w • • • • D 230, H 148
Series: Andho TC Flat IP 65
Type of protection: IP 65 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Housing: aluminium extrusion profile, powder‑coated; ceiling base: die‑cast aluminium, powder‑coated, with bayonet fixing; cover ring: die‑cast aluminium, powder‑coated, screwed on the luminaire; safety glass, transparent; reflector: aluminium, highly polished anodised finish; EB incorporated, 5‑pole double terminal for through‑wiring.
Ballast: EB
Available colours (X): 2 = white, 4 = silver metallic
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
H
D
178
45178
Ø230
Ø7
h
d c b
a
216
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Ceiling (recessed)
Arelo® Type of protection: IP 20
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Recessed ring made of die-cast aluminium
- Top quality reflector made of aluminium, highly polished anodised finish
- Wide beam light distribution
- All versions with EB in separate ballast box
- Simple spring system for installation without tools
217
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Ceiling (recessed)
Cover screens with spring fastening IP 43981734.000 Safety glass, transparent
Spacing table 671871.962
Luminaire luminous flux:
Mains: 2400 lm, Emergency: 2400 lm
The following values are indicated in m
h a b c d
2.5 10.3 4.7 10.6 4.9
3.0 12.3 5.4 12.7 5.8
3.5 13.7 6.0 14.8 6.5
4.0 15.0 6.6 16.2 7.2
Spacing table 671869.962
Lamp luminous flux:
Mains: 1200 lm, Emergency: 1200 lm
The following values are indicated in m
h a b c d
2.5 10.4 4.5 10.8 4.9
3.0 11.8 4.9 12.4 5.4
3.5 13.0 5.3 13.8 6.0
4.0 14.0 5.9 15.1 6.4
Spacing table 671870.952
Lamp luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
h a b c d
2.5 11.6 4.9 11.3 5.1
3.0 12.8 5.6 13.1 5.8
3.5 14.2 6.0 14.6 6.5
4.0 15.5 6.4 16.0 6.9
Spacing table 671872.952
Luminaire luminous flux:
Mains: 3600 lm, Emergency: 3600 lm
The following values are indicated in m
h a b c d
2.5 10.4 4.7 10.6 4.9
3.0 12.4 5.6 12.7 5.8
3.5 14.4 6.3 14.8 6.8
4.0 15.8 6.9 16.9 7.5
Article number Type of installation
Lamps Mains/
Emergency
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671869.96X.y Ceiling (recessed) 1 / 1 1 x TC‑DEL 18 w • • • • D 218, H 3, DA 200, HE 106
671871.96X.y Ceiling (recessed) 2 / 2 2 x TC‑DEL 18 w • • • • D 218, H 3, DA 200, HE 106
671870.95X.y Ceiling (recessed) 1 / 1 1 x TC‑DEL 26 w • • • • D 218, H 3, DA 200, HE 106
671872.95X.y Ceiling (recessed) 2 / 2 2 x TC‑DEL 26 w • • • • D 218, H 3, DA 200, HE 106
Series: Arelo®
Type of protection: IP 20 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 1‑25 mm
For escape route illumination
Mounting frame: die‑cast aluminium, powder‑coated; bracket: galvanised sheet steel; reflector: aluminium, highly polished anodised finish, separate ballast box; length of cable between luminaire and ballast box: 400 mm; suitable for through‑wiring.
Ballast: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
HE
DAD
H
Ø218 Ø200
h
d c b
a
218
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
wall (surface), Ceiling (surface)Semi‑recessed installation (wall, ceiling)
Mondana Type of protection: IP 65
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Design matches modern architectural styles
- Diffuser: glass or PE sintered glass (polyethylene), shockproof
- IP 65 provides safe protection against humidity - dust and insects cannot penetrate the luminaire
- Gore™ diaphragm valve for pressure equalisation and prevention of condensation
- Easy to install
- Wide range of applications thanks to various types of installation
- Lamp replacement without tools
219
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (surface), Ceiling (surface) D 500 and D 550
Semi‑recessed installation (wall, ceiling) DA 310
wall (surface), Ceiling (surface) D 390
Semi‑recessed installation (wall, ceiling) DA 390
Spacing table 671801.00X und 671981.00X
Lamp luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
h a b c d
2.5 11.9 4.7 11.9 4.7
3.0 12.7 4.9 12.7 4.9
3.5 13.4 5.1 13.4 5.1
4.0 14.0 5.3 14.0 5.3
Spacing table 671800.80X
Luminaire luminous flux:
Mains: 5000 lm, Emergency: 5000 lm
The following values are indicated in m
h a b c d
2.5 14.5 5.8 14.5 5.8
3.0 17.4 7.0 17.4 7.0
3.5 18.6 7.5 18.6 7.5
4.0 19.6 7.8 19.6 7.8
Spacing table 671790.80X
Luminaire luminous flux:
Mains: 5000 lm, Emergency: 5000 lm
The following values are indicated in m
h a b c d
2.5 14.5 5.8 14.5 5.8
3.0 17.4 7.0 17.4 7.0
3.5 18.6 7.5 18.6 7.5
4.0 19.6 7.8 19.6 7.8
Spacing table 671799.80X
Luminaire luminous flux:
Mains: 5000 lm, Emergency: 5000 lm
The following values are indicated in m
h a b c d
2.5 14.5 5.8 14.5 5.8
3.0 17.4 7.0 17.4 7.0
3.5 18.6 7.5 18.6 7.5
4.0 19.6 7.8 19.6 7.8
Spacing table 671791.80X
Luminaire luminous flux:
Mains: 5000 lm, Emergency: 5000 lm
The following values are indicated in m
h a b c d
2.5 11.6 5.8 11.5 5.8
3.0 16.9 7.0 16.9 7.0
3.5 19.5 7.8 19.5 7.8
4.0 20.5 8.2 20.5 8.2
Accessories | Moulded housing
Moulded housing 981630.002 for Mondana D 390981631.002 for Mondana D 500981631.002 for Mondana D 550
Article number Type of installation
Type Lamps Mains/
Emergency
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671801.00X.y Semi‑recessed instal‑lation (wall, ceiling) glass 1 / 1 1 x T16‑R 22 w • • • • D 390, H 57
DA 310, HE 96
671800.80X.y Semi‑recessed instal‑lation (wall, ceiling) glass 2 / 2 1 x T16‑R 22 w +
1 x T16‑R 40 w • • • • D 500, H 78 DA 390, HE 100
671799.80X.y Semi‑recessed instal‑lation (wall, ceiling) PE 2 / 2 1 x T16‑R 22 w +
1 x T16‑R 40 w • • • • D 550, H 85 DA 390, HE 100
671781.00X.y wall (surface), Ceiling (surface) glass 1 / 1 1 x T16‑R 22 w • • • • D 390, H 101
671790.80X.y wall (surface), Ceiling (surface) glass 2 / 2 1 x T16‑R 22 w +
1 x T16‑R 40 w • • • • D 500, H 128
671791.80X.y wall (surface), Ceiling (surface) PE 2 / 2 1 x T16‑R 22 w +
1 x T16‑R 40 w • • • • D 550, H 135
Series: Mondana
Type of protection: IP 65 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 10‑30 mm
For escape route illumination
Base: plastic (polycarbonate), microstructure coating; diffuser: plastic (polyethylene) or mouth‑blown opal glass, satin finish; diffuser fastening: screwneck; housing for semi‑recessed installation in walls and ceilings: powder‑coated aluminium. Standard gore™ Protective Vents diaphragm valve for reduction of condensation.
Ballast: EB
Available colours (X): 2 = white, 4 = silver metallic
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
D H
D H
HE
DA
D H
D H
HE
DA
Ø310
13170
Ø300
Ø5,5
70Ø390
140
5242,5
Ø380
Ø5,5
7065
h
d c b
a
220
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Flat Polymero® Type of protection: IP 40
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Design matches modern architectural styles
- Compact design
- Extremely high Light Output Ratio of up to 81%
- Easy to install
- Low maintenance costs
- Wide range of applications thanks to various types of installation
wall (surface), Ceiling (surface)
221
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Serie: Flat Polymero®
Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Base: powder‑coated metal; diffuser: plastic (PMMA), opal, or plastic (polycarbonate), shockproof. Diffuser fastening with patented system (push system).
Ballast: EB
Available colour (X): 2 = white
wall (surface), Ceiling (surface)
Spacing table 671952.002.1 und 671952.002.2
Lamp luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
h a b c d
2.5 13.9 5.3 13.9 5.3
3.0 14.8 5.8 14.8 5.8
3.5 15.7 6.0 15.7 6.0
4.0 16.4 6.4 16.4 6.4
Article number Type of installation
Type Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671952.00X.1.y wall (surface), Ceiling (surface) PMMA 1 x T16‑R 22 w • • • • D 360, H 100
671952.00X.2.y wall (surface), Ceiling (surface) PC 1 x T16‑R 22 w • • • • D 360, H 100
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
D
H
100
173
Ø324
Ø5,5
5030
25
h
d c b
a
222
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Flat Polymero® PMMA
Flat Polymero® PC
Type of protection: IP 43 (Ceiling (surface)), IP 44 (Wall (surface))
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Architecturally attractive design
- Compact design
- Easy to install
- With spring system - for opening the luminaire without tools - for gently detaching and positioning the diffuser
wall (surface), Ceiling (surface)
223
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (surface), Ceiling (surface)
Accessories | Decorative rings, metal, for series: Flat Polymero® PMMA and PCAvailable colours: Decorative ring, painted (Z): 2 = white, 61 = ultramarine blue, 76 = rape yellow, 82 = ruby red, 9 = light grey. other RAL colours available on request
Available colours: Decorative ring, metallised (Z): 4 = chrome, 42 = nickel, matt, 5 = brass
Decorative rings, metalDecorative ring D 325 mm, for diffuser D 305 mm981224.00Z D 325, H 10
Spacing table 671959.952.2
Lamp luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
h a b c d
2.5 13.0 5.2 13.0 5.2
3.0 13.1 5.6 13.1 5.6
3.5 14.3 5.8 14.3 5.8
4.0 15.1 6.1 15.1 6.1
Spacing table 671958.962.1
Lamp luminous flux:
Mains: 1200 lm, Emergency: 1200 lm
The following values are indicated in m
h a b c d
2.5 10.8 4.6 10.8 4.6
3.0 12.1 4.8 12.1 4.8
3.5 12.8 5.0 12.8 5.0
4.0 12.8 5.2 12.8 5.2
Spacing table 671959.952.1
Lamp luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
h a b c d
2.5 13.0 5.2 13.0 5.2
3.0 13.1 5.6 13.1 5.6
3.5 14.3 5.8 14.3 5.8
4.0 15.1 6.1 15.1 6.1
Spacing table 671958.962.2
Lamp luminous flux:
Mains: 1200 lm, Emergency: 1200 lm
The following values are indicated in m
h a b c d
2.5 10.8 4.6 10.8 4.6
3.0 12.1 4.8 12.1 4.8
3.5 12.8 5.0 12.8 5.0
4.0 12.8 5.2 12.8 5.2
Article number Type of installation
Type Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671958.96X.1.y wall (surface), Ceiling (surface) PMMA 1 x TC‑DEL 18 w • • • • D 305, H 115
671958.96X.2.y wall (surface), Ceiling (surface) PC 1 x TC‑DEL 18 w • • • • D 305, H 115
671959.95X.1.y wall (surface), Ceiling (surface) PMMA 1 x TC‑DEL 26 w • • • • D 305, H 115
671959.95X.2.y wall (surface), Ceiling (surface) PC 1 x TC‑DEL 26 w • • • • D 305, H 115
Series: Flat Polymero® PMMA and PC
Type of protection: IP 43 Ceiling (surface), IP 44 wall (surface) Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Base: plastic; diffuser: plastic (PMMA) or plastic (polycarbonate), opal; diffuser fastening: spring system.
Ballast: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
D
H
Ø
100
50205
Ø305Ø262
Ø5
h
d c b
a
224
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
wall (surface), Ceiling (surface)
Flat Basic Type of protection: IP 43 (Ceiling (surface)), IP 44 (Wall (surface))
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- A design that fits well with modern architecture
- Low maintenance costs
- Compact design
- Easy to install
- Spring system or bayonet fixing allow for smooth attachment and removal of diffuser - without tools
225
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (surface), Ceiling (surface) D 300 wall (surface), Ceiling (surface) D 370 wall (surface), Ceiling (surface) D 420 wall (surface), Ceiling (surface) D 500
Accessories | Decorative rings, metal, for series: Flat BasicAvailable colours decorative ring, painted (Z): 2 = white, 61 = ultramarine blue, 76 = rape yellow, 82 = ruby red, 9 = light grey. other RAL colours available on request
Available colours: Decorative ring, metallised (Z): 4 = chrome, 42 = nickel, matt, 5 = brass
Decorative rings, metalDecorative ring D 320 mm, for glass D 300 mm981098.00Z D 320, H 10Decorative ring D 390 mm, for glass D 370 mm981129.00Z D 390, H 10Decorative ring D 440 mm, for glass D 420 mm981100.00Z D 440, H 10
Spacing table 671954.842
Lamp luminous flux:
Mains: 1200 lm, Emergency: 1200 lm
The following values are indicated in m
h a b c d
2.5 12.7 5.4 12.7 5.4
3.0 13.4 5.7 13.4 5.7
3.5 14.5 6.1 14.5 6.1
4.0 15.6 6.3 15.6 6.3
Spacing table 671956.952
Lamp luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
h a b c d
2.5 14.3 6.1 14.3 6.1
3.0 15.4 6.5 15.4 6.5
3.5 16.0 6.9 16.0 6.9
4.0 17.0 7.3 17.0 7.3
Spacing table 671957.002
Lamp luminous flux:
Mains: 4400 lm, Emergency: 4400 lm
The following values are indicated in m
h a b c d
2.5 16.5 7.3 16.5 7.3
3.0 19.2 7.9 19.2 7.9
3.5 20.2 8.4 20.2 8.4
4.0 20.7 8.8 20.7 8.8
Spacing table 671953.922
Lamp luminous flux:
Mains: 900 lm, Emergency: 900 lm
The following values are indicated in m
h a b c d
2.5 11.4 4.9 11.4 4.9
3.0 12.5 5.2 12.5 5.2
3.5 13.7 5.5 13.7 5.5
4.0 14.5 5.7 14.5 5.7
Spacing table 671955.952
Lamp luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
h a b c d
2.5 14.3 6.1 14.3 6.1
3.0 15.4 6.5 15.4 6.5
3.5 16.0 6.9 16.0 6.9
4.0 17.0 7.3 17.0 7.3
Article number Type of installation
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671953.92X.y wall (surface), Ceiling (surface) 1 x TC‑DEL 13 w – – – – D 300, H 106
671955.95X.y wall (surface), Ceiling (surface) 1 x TC‑DEL 26 w • • • • D 370, H 118
671956.95X.y wall (surface), Ceiling (surface) 1 x TC‑DEL 26 w • • • • D 420, H 124
671954.84X.y wall (surface), Ceiling (surface) 1 x TC‑TEL 18 w – – – – D 300, H 106
671957.00X.y wall (surface), Ceiling (surface) 1 x T16‑R 55 w • • • • D 500, H 150
Series: Flat Basic
Type of protection: IP 43 Ceiling (surface), IP 44 wall (surface) Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Base: plastic, white; diffuser: mouth‑blown opal glass, satin finish; glass fastening: spring system or bayonet fixing.
Ballast: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
D
H
Ø
D
H
Ø
D
H
Ø
D
H
Ø
170
Ø201300
26Ø5
R76
100
50205
Ø262370
Ø5
100
50205
Ø262420
Ø5
52Ø280
Ø38058
Ø5
Ø50048
1
2
3x120°
h
d c b
a
226
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Flat Polymero® Rechteck Type of protection: IP 40
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Design matches modern architectural styles
- Very large viewing distance with motifs
- Flat design
- Luminaire can be opened without tools
wall (surface) wall (surface), Ceiling (surface)
227
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (surface), Ceiling (surface)
Spacing table 671979.752
Lamp luminous flux:
Mains: 2000 lm, Emergency: 2000 lm
The following values are indicated in m
h a b c d
2.5 13.6 5.6 13.6 5.6
3.0 13.7 6.0 13.7 6.0
3.5 14.9 6.3 14.9 6.3
4.0 16.0 6.5 16.0 6.5
Spacing table 671978.752
Lamp luminous flux:
Mains: 1350 lm, Emergency: 1350 lm
The following values are indicated in m
h a b c d
2.5 11.4 4.9 11.4 4.9
3.0 12.5 5.2 12.5 5.2
3.5 13.7 5.5 13.7 5.5
4.0 14.5 5.7 14.5 5.7
Article number Type of installation
Luminous flux factor
Lamps Mains/
Emergency
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671978.75X.y wall (surface), Ceiling (surface) 50 m 2 / 1 2 x T16 (T5) 14 w • • • • L 600, B 320, H 75
671979.75X.y wall (surface), Ceiling (surface) 50 m 2 / 1 2 x T16 (T5) 24 w • • • • L 600, B 320, H 75
Series: Flat Polymero® Rechteck
Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 50 m
For escape route identification (only in case of wall installation) or escape route illumination.
Base: metal, powder‑coated. Diffuser: plastic (PMMA), opal. Diffuser fastening: sash lock, plastic.
Please quote symbol number when ordering escape route motifs!
Ballast: EB
Available colour (X): 2 = white
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
50 m
L
B H
48 306245320
581
530600
Ø5,5
h
d c b
a
228
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Rounded® extra flat Type of protection: IP 54
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Fits well with modern architecture
- Housing made of top quality die-cast aluminium
- Low maintenance costs
- Compact design
- Easy to install
- Flat design
- IP 54 type of protection - dustproof and protected against water spray
wall (surface), Ceiling (surface) wall (semi‑recessed)
229
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Series: Rounded® extra flat
Type of protection: IP 54 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Base: die‑cast aluminium, powder‑coated. Diffuser: glass, opal, mouth‑blown, satin finish, or plastic (polycarbonate), opal.
Ballast: EB
Available colours (X): 2 = white, 31 = anthracite metallic, 4 = silver metallic
wall (surface), Ceiling (surface) wall (semi‑recessed)
Plastic moulded housing981095.000
Spacing table 671965.95X, 671967.95X und 671971.95X
Lamp luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
h a b c d
2.5 12.2 5.2 12.2 5.2
3.0 12.9 5.5 12.9 5.5
3.5 13.9 5.8 13.9 5.8
4.0 15.0 6.1 15.0 6.1
Spacing table 671964.96X und 671966.96X
Lamp luminous flux:
Mains: 1200 lm, Emergency: 1200 lm
The following values are indicated in m
h a b c d
2.5 10.6 4.5 10.6 4.5
3.0 11.7 4.8 11.7 4.8
3.5 12.8 5.1 12.8 5.1
4.0 12.4 5.2 12.4 5.2
Spacing table 671968.96X und 671970.96X
Lamp luminous flux:
Mains: 1200 lm, Emergency: 1200 lm
The following values are indicated in m
h a b c d
2.5 10.6 4.5 10.6 4.5
3.0 11.7 4.8 11.7 4.8
3.5 12.8 5.1 12.8 5.1
4.0 12.4 5.2 12.4 5.2
Article number Type of installation
Viewing distance
Type Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671968.96X wall (surface), Ceiling (surface) ‑ glass 1 x TC‑DEL 18 w ‑ ‑ ‑ ‑ D 270, H 110
671970.96X wall (surface), Ceiling (surface) ‑ PC 1 x TC‑DEL 18 w ‑ ‑ ‑ ‑ D 270, H 110
671969.95X wall (surface), Ceiling (surface) ‑ glass 1 x TC‑DEL 26 w ‑ ‑ ‑ ‑ D 270, H 110
671971.95X wall (surface), Ceiling (surface) ‑ PC 1 x TC‑DEL 26 w ‑ ‑ ‑ ‑ D 270, H 110
671964.96X wall (semi‑recessed) ‑ glass 1 x TC‑DEL 18 w ‑ ‑ ‑ ‑ D 270, H 80, HE 22
671966.96X wall (semi‑recessed) ‑ PC 1 x TC‑DEL 18 w ‑ ‑ ‑ ‑ D 270, H 80, HE 22
671965.95X wall (semi‑recessed) ‑ glass 1 x TC‑DEL 26 w ‑ ‑ ‑ ‑ D 270, H 80, HE 22
671967.95X wall (semi‑recessed) ‑ PC 1 x TC‑DEL 26 w ‑ ‑ ‑ ‑ D 270, H 80, HE 22
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
D H
Ø237
HE
D H
Ø258
80
75
170
Ø270
Ø6
22Ø258
80
75
170
Ø270
Ø235Ø6
h
d c b
a
230
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Alu-Lux oval
Alu-Rund
Type of protection: IP 54
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Modern design
- Housing made of sturdy die-cast aluminium
- Low maintenance costs
- Compact design
- Easy to install
- With glass cover
wall (surface), Ceiling (surface) wall (surface), Ceiling (surface)
231
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Series: Alu‑Lux oval
Type of protection: IP 54 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Base: die‑cast aluminium, powder‑coated. glass: frosted inside.
Ballast: EB
Available colours (X): 2 = white, 3 = black
wall (surface), Ceiling (surface) wall (surface), Ceiling (surface)
Series: Alu‑Rund
Type of protection: IP 54 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Base: die‑cast aluminium, powder‑coated. glass: frosted inside.
Ballast: EB
Available colours (X): 2 = white, 3 = black
Spacing table 671963.96X
Lamp luminous flux:
Mains: 1200 lm, Emergency: 1200 lm
The following values are indicated in m
h a b c d
2.5 12.9 5.5 12.7 5.5
3.0 13.1 5.9 14.8 5.8
3.5 14.0 6.1 14.2 6.0
4.0 15.2 6.3 15.1 6.1
Spacing table 671972.92X
Lamp luminous flux:
Mains: 900 lm, Emergency: 900 lm
The following values are indicated in m
h a b c d
2.5 12.3 5.2 12.3 5.2
3.0 13.7 5.4 13.7 5.4
3.5 13.3 5.6 13.3 5.6
4.0 14.5 5.7 14.5 5.7
Spacing table 671973.96X
Lamp luminous flux:
Mains: 1200 lm, Emergency: 1200 lm
The following values are indicated in m
h a b c d
2.5 14.2 5.7 14.2 5.7
3.0 14.3 6.0 14.3 6.0
3.5 15.9 6.3 15.9 6.3
4.0 15.2 6.5 15.2 6.5
Article number Type of installation
Type Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671963.96X wall (surface), Ceiling (surface) Alu‑Lux oval 1 x TC‑DEL 18 w ‑ ‑ ‑ ‑ L 280, B 160, H 140
671972.92X wall (surface), Ceiling (surface) Alu‑Rund 1 x TC‑DEL 13 w ‑ ‑ ‑ ‑ D 240, H 130
671973.96X wall (surface), Ceiling (surface) Alu‑Rund 1 x TC‑DEL 18 w ‑ ‑ ‑ ‑ D 240, H 130
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
L
H
B
45
30
175285
30
Ø5
165
D H
4530
1565
40
Ø240
Ø5
h
d c b
a
232
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
wall (surface)
Light Case Type of protection: IP 54
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Modern design
- Low maintenance costs
- Ball impact protection in acc. with DIN 18032
- Easy to install
- Ballasts incorporated
233
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (surface)
Spacing table 671974.813
Lamp luminous flux:
Mains: 2400 lm, Emergency: 2400 lm
The following values are indicated in m
h a b c d
2.5 7.7 3.5 10.5 4.9
3.0 9.0 3.9 12.5 5.6
3.5 10.0 4.4 13.9 6.0
4.0 11.0 4.7 15.3 6.6
Article number Type of installation
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671974.81X.y wall (surface) 1 x TC‑TEL 32 w • • • • L 230, B 230, H 150
Series: Light Case
Type of protection: IP 54 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Housing: sheet steel, powder‑coated. Removable frame: aluminium, powder‑coated. Safety glass: transparent. Hinges: stain‑less steel. Two cable inlets for through‑wiring, cable diameter 7‑10 mm. Luminaire equipment installed. Ball impact protected in accordance with DIn 18032.
Ballast: EB
Available colour (X): 3 = black
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
B
H
L
230
47
230
60
130
130
Ø6
h
d c b
a
234
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
wall (surface), Ceiling (surface)
Weatherproof battens Type of protection: IP 65
- IP 65 type of protection - dustproof and protected against water jets from all directions
- Industrial design
- Lamp replacement without tools
235
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Accessories | Protective tubes for weatherproof battens
Replacement diffuser, plastictransparent981441.000 L 1170, D 38 for T26 36 w981442.000 L 1470, D 38 for T26 58 w
Spacing table 671616.759
Lamp luminous flux:
Mains: 3350 lm, Emergency: 3350 lm
The following values are indicated in m
h a b c d
2.5 13.9 6.0 23.0 9.5
3.0 15.6 6.6 23.5 10.0
3.5 16.3 7.0 25.9 10.5
4.0 17.9 7.4 27.4 10.9
Spacing table 671617.759
Lamp luminous flux:
Mains: 5400 lm, Emergency: 5400 lm
The following values are indicated in m
h a b c d
2.5 15.7 6.8 26.3 11.1
3.0 17.3 7.4 28.3 11.8
3.5 18.9 8.0 31.4 12.4
4.0 20.3 8.5 32.2 13.0
Article number Type of installation
Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671616.75X.y wall (surface), Ceiling (surface) 1 x T26 (T8) 36 w • • • • L 1258, B 56, H 122
671617.75X.y wall (surface), Ceiling (surface) 1 x T26 (T8) 58 w • • • • L 1558, B 56, H 122
Series: Weatherproof battens
Type of protection: IP 65 Protection class: I, II Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Housing: plastic, grey. Lamp: open beam. Integrated EB.
Ballast: EB
Available colour (X): 9 = grey
wall (surface), Ceiling (surface) 36 w wall (surface), Ceiling (surface) 58 w
Planning guide: Escape route illumination in accordance with EN 1838
E = 1 lx along the centre line
H
BL
H
BL
62
740
1258
Ø10
62
1050
1558
Ø10
h
d c b
a
236
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
Alu-Druckguss (die-cast aluminium) Type of protection: IP 66
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Modern design
- Housing made of top quality die-cast aluminium
- Low maintenance costs
- Compact design
- Easy to install
Recessed wall installation, antiglare Recessed wall installation, with diffuser
237
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
Series: Alu‑Druckguss (die‑cast aluminium)
Type of protection: IP 66 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Housing and frame: die‑cast alumi‑nium, powder‑coated. Cover: plastic, opal, shockproof.
Ballast: EB
Available colours (X): 2 = white, 3 = black, 9 = grey
Series: Alu‑Druckguss (die‑cast aluminium)
Type of protection: IP 66 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Housing and frame: die‑cast alumi‑nium, powder‑coated. Cover: plastic, opal, shockproof.
Ballast: EB
Available colours (X): 2 = white, 3 = black, 9 = grey
Recessed wall installation Recessed wall installation
Housing for recessed wall and step luminaires Recess opening: LA 232 x BA 92 mm, max. wall thickness: 20 mm90‑2780
Moulded housing for installation in concrete walls 64253.000
Article number Type of installation
Type Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671975.91X Recessed wall installation antiglare 1 x TC‑EL 9 w ‑ ‑ ‑ ‑ L 236, B 100, H 5
LA 228 x BA 85, HE 70
671976.91X Recessed wall installation with diffuser 1 x TC‑EL 9 w ‑ ‑ ‑ ‑ L 236, B 100, H 5
LA 228 x BA 85, HE 70
BBA
L
LA
HE
H
B
L
LA
BA
HE
H
85
228236
100 85
228236
100
238
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
wall (recessed) (solid wall)
Recessed LED step luminaire for installation in concrete steps Type of protection: IP 66
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.
- Modern design
- Housing made of top quality die-cast aluminium
- Low maintenance costs
- Compact design
- Easy to install
239
EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy
For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration
wall (recessed) (solid wall)
Series: Recessed LED step luminaire for installation in concrete steps
Type of protection: IP 66 Protection class: I with EB, III without EB Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz
For escape route illumination
Housing: sheet steel, galvanised. Cover: polycarbonate, transparent. Lamellar cover: die‑cast zinc, powder‑coated. The luminaire housing is used as the moulded housing. During installation, the LED module must be removed from the luminaire housing.Two cable inlets with sleeves for M32 armoured cable (outer sleeve Ø: 24.5 mm, inner Ø: 21 mm).
LED module with electronic ballast (connected load: 10 w). The max. connected load of the EB must not be exceeded!
Prepared for through‑wiring.
Ballast: EB
Available colours (X): 31 = anthracite metallic, 4 = silver metallic
Article number Type of installation
Type Lamp/wattage Control 1 (.71)
TwIn‑Control
(.72)
SIngLE‑Control
(.81)
DUo‑Control
(.82)
Dimensions
671977.00X wall (recessed) (solid wall) with EB 1 x LED 1,92 w ‑ ‑ ‑ ‑ L 210, B 90, H 5
LA 190 x BA 70, HE 110
671980.00X wall (recessed) (solid wall ) without EB 1 x LED 1,92 w ‑ ‑ ‑ ‑ L 210, B 90, H 5
LA 190 x BA 70, HE 110
B
LAL
BA
HE
H
70
25
190
122,5
110
240
241
Standards and regulations
European and international regulations
EN 1838 Emergency lighting 242 - 243
EN 50172 Emergency escape lighting systems 244
EN 50171 Central power supply systems 245
EN 50272-2 Stationary batteries 245
EN 60598-2-22 Particular requirements 246 Luminaires for emergency lighting
German regulations
VDE 0108, Part 100, Emergency lighting 246
DIN 4844 -1 Safety signs 262 Viewing distances
DIN 4844 -2 Safety signs 262 Sign design
VDE 0100, Part 560, Systems with nominal voltages of 263 up to 1,000 V
VDE 0100, Part 718, Buildings for gatherings of people 263
(M)LAR (Model) Wiring systems directive 264
Special building directives 264
ASR Workplace directives 265
BGV Safe working practices regulations 262
Planning 268 - 269
Exclusion of liability
RZB shall not be liable for any loss or damage attributable to any application of, or failure to apply, any information supplied herein. Excerpts from the aforementioned standards and regulations are provided for information purposes only. Other local building regulations may apply.
Inasmuch as the applicable requirements, standards and regulations are subject to change, the relevant original versions of such standards and regulations must be applied in each case.
242
p
d
EuROPEAN AND INtERNAtIONAL REGuLAtIONS
Specifications subject to alteration
Definition of “emergency lighting”
Viewing distances Legend
Safety signs for escape routes must comply with the following requirements:
• Viewing distance (d): formula: d= s x p
p = sign height
s = distance factor 100 (externally illuminated signs) and distance factor 200 (internally lit signs)
Safety signs for escape routes must comply with the following requirements:
the ratio of white colour to green colour luminance must be between 5:1 and 15:1.
the ratio of maximum to minimum luminance shall be less than 10:1 for each colour.
Luminance:
the minimum luminance of any green area (safety colour) on the sign must be greater than 2 cd/square meters.
Example:
Calculation of an internally lit sign’s height for a required viewing distance of 30 m (d = 30)
Applicable equation:
d = s x p p = d / s
p = 30 / 200 = 0.15 m (sign height)
Emergency lighting
Emergency escape lighting Standby lighting
Escape route lighting Anti-panic lighting (Open area lighting)
High risk task area lighting
Contrast colourSafety colour
EN 1838 – EMERGENCY LIGHtING
243
EuROPEAN AND INtERNAtIONAL REGuLAtIONS
Specifications subject to alteration
Specific locations where a luminaire must be provided
at each mandatory exit door
near* stairs so that each staircase step receives direct light
near* any other change of floor level
near* each mandatory safety sign
at each change of direction
at each intersection of corridors
outside and near* each final exit
near* each first aid post
near* each piece of fire fighting equipment and call point
*Note:the term “near” means within 2 meters.First aid posts, fire fighting equipment and call points that are located outside the escape route must be illuminated with a minimum of 5 lux.
EN 1838 – EMERGENCY LIGHtING
244
EuROPEAN AND INtERNAtIONAL REGuLAtIONS
Specifications subject to alteration
General
the purpose of emergency escape lighting is to ensure that lighting is provided promptly, automatically and for a suitable time in a specific area during a power failure.
the installation is to be realized in such a way that emergency escape lighting accomplishes the following (among other things):
- illuminates escape route signs;
- illuminates escape routes leading to emergency exits;
- ensures that fire alarm call points and fire equipment provided along escape routes can be readily located and used (if required);
- etc.
Emergency escape lighting is to be activated not only on complete failure of the supply to the general lighting but also in the event of a final-circuit failure.
Emergency escape lighting is not designed to enable normal work to be continued on the premises in the event of failure of normal or standby lighting.
For details concerning illuminance levels and measurement, see EN 1838.
Visibility
In locations where building occupants (a) do not have a clear and unobstructed view of an exit sign and/or (b) may have doubts as to the location of an emergency exit, a directional sign (or series of signs) is to be provided in such a way that a person moving toward such sign will be directed to an emergency exit.
An exit or directional sign is to be clearly visible at all points along the escape route.
All signs marking exits and / or escape routes are to be uniform in colour and format, and their luminance is to comply with EN 1838.
Maintained exit signs must be installed for applications where occupants may be unfamiliar with the building.
Anti-panic lighting (Open area lighting)
the purpose of open area (anti-panic) lighting is to reduce the likelihood of panic and to enable safe movement of occupants toward escape routes.
Such lighting is used in areas with undefined escape routes. Such areas may include halls or premises exceeding 60 square meters in size, or smaller areas if there is an additional hazard such as use by a large number of people.
Log book
A log book is to be kept on the premises in the care of a responsible person appointed by the occupant/owner and is to be readily available for examination by any duly authorized person.
the log book is to be used to record the following information:
- date of commissioning of the system including any certificate relating to changes;
- date of each periodic inspection and test;
- dates and brief details of any maintenance, inspection and test;
- dates and brief details of any defects and of remedial action taken;
- date and brief details of any change in the emergency lighting installation;
- if any automatic testing device is employed, the main characteristics and mode of operation of that device are to be described.
Maintenance and testing
Daily:
Indicators of the central power supply are to be visually inspected for correct operation.
Monthly:
If automatic testing devices are used, the results of the function tests are to be recorded.
Monthly tests are to be carried out as follows:
- a) Switch on in the emergency mode each luminaire and each internally illuminated exit sign via its battery by simulation of a failure of the supply to the general lighting for a period sufficient to ensure that each lamp is illuminated.
- During this period, all luminaires and signs are to be checked to ensure that they are present, clean and functioning correctly.
- At the end of this test period, the power supply to the general lighting is to be restored and any indicator lamp or device is to be checked to ensure that it shows that the normal supply has been restored.
In addition to a), for central battery systems, the correct operation of system monitors is to be checked.
Annually:
If automatic testing devices are used, the results of the full rated duration test are to be recorded.
A monthly inspection is be carried out for all other systems, whereby the following additional tests are to be carried out:
- each luminaire and internally illuminated sign is to be tested for its full rated duration in accordance with the manufacturer‘s recommendations;
- the power supply for general lighting is to be restored and any indicator lamp or device is to be checked to ensure that it is showing that normal supply has been restored. the charging arrangements should be checked for proper functioning;
- the date of the test and its results are to be recorded in the system log book.
EN 50172 – EMERGENCY ESCAPE LIGHtING SYStEMS
245
EuROPEAN AND INtERNAtIONAL REGuLAtIONS
Specifications subject to alteration
Battery chargers must be capable of automatically charging the associated battery that has been discharged so that it can perform at least 80% of the specified duration at the rated load within 12 h.
Central Power Supply (CPS)
Central power supply without any restriction in respect to rated output power.
Ventilation
Batteries are to be installed in well ventilated rooms and cabinets. the minimum cross section of the ventilation opening is to correspond to battery capacity.
Such openings need to be adequately positioned to allow for optimum air exchange (e.g. in opposite walls).
Batteries are to be located at least 2 m from wall openings.
Exhaust air must be discharged outside the building.
Location
Batteries are to be installed in protected rooms, if required, electrical or closed electrical operating rooms are to be provided.
the batteries may be kept:
- in special rooms on the premises
- in specific separate areas on the premises
- in enclosures or cabinets on or off the premises
- in battery compartments that are integrated into devices (twin housing)
Specific requirements for battery rooms
the floor must be rated for the battery weight, and allowance is to be made for the possibility that additional batteries (and hence weight) will be installed down the line.
If only authorized personnel are allowed to access to battery rooms, the doors are to be equipped with anti-panic locks.
the floors used for sealed batteries are to be electrolyte resistant. If this is not the case, the batteries are to be placed in acid drip pans.
the floor area for a person standing within arm’s reach of the battery is to be electrostatic dissipative in order to prevent electrostatic charge generation.
Ventilation must comply with EN 50272 and the exhaust air must be discharged outside the building.
Low Power Supply (LPS)
Central power supply with a limited rated output power:
- 3 h = 500 W
- 1h = 1, 500 W
Information and warning signs
Appropriate information and warning signs (pursuant to EN 50272 section 12.1) need to be posted in battery rooms.
Documentation
Documentation containing the following information must be available near the battery:
- Name of manufacturer or vendor
- Name of installer
- Date of commissioning
- Manufacturer’s or vendor’s type designation
- Nominated voltage of battery
- Nominal capacity with indication of discharge time
- Safety recommendations
- Recommendations for operating and maintenance
- Information regarding disposal and recycling
Such documentation must be at all maintenance and operating personnel’s disposal.
Inspections
Batteries and their operation conditions have to be checked at regular intervals for correct operation and safety.
During such inspections and controls it must be verified whether the following items conform with the manufacturer’s specifications:
- Voltage set for the battery charger
- Voltage of battery cells/blocks
- Electrolyte density and level (if applicable)
- Cleanliness
- tightness
- Battery connector position (if required)
- Ventilation
- Plugs and valves
- Battery temperature
EN 50171 – CENtRAL POWER SuPPLY SYStEMS
EN 50272 – StAtIONARY BAttERIES
246
EuROPEAN AND INtERNAtIONAL REGuLAtIONS
Specifications subject to alteration
In emergency luminaires, fluorescent lamps used to provide emergency lighting are to come on without the aid of glow starters. Such starters are not to be in circuit during emergency mode operation. Emergency lighting shall not be provided by means of fluorescent lamps with built-in glow starters.
Self-contained luminaires must be recharged within 24 hours following discharge.
the ambient temperature of the battery cells should be at least 5°C; however, an occasional temperature drop to 0°C is admissible.
* in accordance with BGV A8
Daily testIndicators for the central power supply are to be visually inspected for correct operation.
Weekly testFunction of emergency lighting is to be checked at least once a week.Connection of the power source for safety purposes is required for battery-powered systems.
Monthly testIf automatic testing devices are used, the results of the function tests are to be recorded.
tests are to be carried out by simulating a general lighting power supply failure.
Yearly testIf automatic testing devices are used, the results of the function tests are to be recorded.the yearly test is not to be activated automatically.
Test at 3 year intervalEvery three years (at the most) emergency lighting illuminance is to be measured as provided in DIN EN 1838.
EN 60598-2-22 – PARtICuLAR REQuIREMENtS / LuMINAIRES FOR EMERGENCY LIGHtING
VDE 0108, PARt 100 – EMERGENCY LIGHtINGIllu
min
ance
Sw
itchi
ng ti
me
Rat
ed d
urat
ion
of p
ower
sou
rce
for s
afet
y pu
rpos
es
Illum
inat
ion
of e
scap
e ro
ute
lum
inai
res,
mai
ntai
ned
Cen
tral b
atte
ry s
yste
m
Gro
up b
atte
ry s
yste
m
Sel
f-co
ntai
ned
lum
inai
res
(as
of
08/2
010)
Pow
er g
ener
atio
n un
it
(with
out i
nter
rupt
ion)
Pow
er g
ener
atio
n un
it (s
witc
hing
tim
e <
0.5
s)
Pow
er g
ener
atio
n un
it (s
witc
hing
tim
e 15
s)
Part
icul
arly
saf
e ne
twor
k
Places of assembly (temporary buildings excluded), theatres, cinemas 1 lx 1s 3 h • • • • • • – –
temporary buildings, used for exhibitions 1 lx 1 s 3 h • • • • • • – –
Exhibition halls 1 lx 1 s 3 h • • • • • • – –
Shops 1 lx 1 s 3 h • • • • • • – –
Restaurants 1 lx 1 s 3h • • • • • • – –
Accomodation facilities, nursing homes
1 lx1 s - 15 s
depending on risk level
8 h (3 h are sufficient, if buttons in accordance with VDE 0108,
part 100, section 4.4.8, are available)
• • • • • • • –
Schools 1 lx1 s - 15 s
depending on risk level
3 h • • • • • • • –
Car-parks, underground parking garages 1 lx 15 s 1 h • • • • • • • –
Airports, railway stations 1 lx 1 s
3 h (depending on the evacuation concept, for above-ground railway station areas 1 h
may be admissible)
• • • • • • – –
Multi-storey buildings 1 lx1 s - 15 s
depending on risk level
3 h ( 8 h for multi-storey residential buildings, if buttons in accordance with VDE 0108, part 100, section
4.4.8, are not available)
• • • • • • • –
Escape routes at workplaces 1 lx 15 s 1 h –* • • • • • • •
High-risk workplaces 15 lx 0.5 s Duration of risk for building occupants • • • • • • – •
Stages 3 lx 1 s 3 h • • • • • • – –
247
EB NEA < 0,5 sec
1,0 lx
BS
CPS
3,0 lx
LPS
En50%5 sec
60 sec100%
DS3h≤ 1,0 sec
GERMAN REGuLAtIONS
Specifications subject to alteration
Places of assembly, theatres and cinemas (excluding temporary buildings)
Model regulation for places of assembly, June 2005 version
- Places of assembly with assembly rooms, used for the gathering together of 200 or more persons
- Outdoor places of assembly (including performance areas) with capacity for 1,000 or more persons
- Sports stadiums with capacity exceeding 5,000 persons
Please note:
the number of persons is to be calculated as follows:
- for table seating: 1 person per square meter of room floorspace
- for seats arranged in rows and for standing room: 2 persons per square meter of room floorspace
- for standing room on bleachers: 2 persons per running meter
- for exhibition rooms: 1 person per square meter of room floorspace
Exceptions:this regulations does not apply to the following:
- rooms used for religious gatherings; school classrooms and exhibition rooms in museums.
Definition:
In places of assembly an emergency escape lighting system must be installed that allows for safe termination of operations on stages and in performance areas, and safe escape of members of the public and staff, even in case of total failure of general lighting.
Emergency escape lighting must be provided:
- for staircases, landings, exits and essential corridors
- in assembly rooms as well as in any rooms/areas that are used by visitors such as foyers, cloakrooms, and lavatories
- for stages and performance areas
- in staff rooms larger than 20 square meters of floorspace, office rooms excluded
- in rooms that accommodate electrical equipment or technical building systems, as well as in spotlight and projector rooms
- for outdoor places of assembly and sports stadiums that are used after dark
- for safety signs of exits and escape routes
- for illumination of steps
In assembly rooms that are darkened for operation, on stages and performance areas, non-maintained safety lighting must be installed. Exits, corridors and stairs in these assembly rooms must be recognizable while these rooms are darkened, irrespective of the remaining emergency lighting. An illumination of stairs is not required for the corridors of assembly rooms containing mobile chairs, as well as for sports stadiums with emergency lighting.
Places of assembly, VDE 0108, Part Teil 100
EN 1838
Stages, VDE 0108, Part 100
Important note:
the above are model regulations only. Regional building code regulations may also apply in certain cases.
MODEL BuILDING CODE REGuLAtIONS VDE 0108, PARt 100 – EMERGENCY LIGHtING
See page 260 for symbol legend
248
EB NEA < 0,5 sec
BS
CPS LPS
DS3h≤ 1,0 sec
1,0 lxEn50%5 sec
60 sec100%
GERMAN REGuLAtIONS
Specifications subject to alteration
Temporary buildings
Model directive concerning the construction, operation and maintenance of temporary buildings (M-FlBauR), May 2007 version
Scope: this directive applies to temporary buildings pursuant to article 76, section 1 of the Model Building Code (MBO).
the provisions of this directive regarding rooms in tents apply also to rooms of similar size that are used for similar purposes in other temporary buildings with more than 200 square meters of floorspace.
Please note:
the number of persons is to be calculated as follows:
- for table seating: 1 person per square meter of room floorspace
- for seats arranged in rows and for standing room: 2 persons per square meter of room floorspace
Exceptions:this directive does not apply to tents used for camping or medical services or for tents with less than 75 square meters of floorspace.
Definition:
Lighting
tents and similar rooms that are used after dark and have more than 200 square meters of floorspace are to be equipped with emergency lighting that conforms with the relevant technical regulations.
the emergency lighting for such rooms is to be illuminated whenever the main lighting is illuminated.
the lighting system is to be powered by the building grid; battery powered luminaires are admissible only if securely installed.
In the event of a general power failure, battery powered luminaires are to be on hand.
Temporary buildings, VDE 0108, Part 100
EN 1838
Important note:
the above are model regulations only. Regional building code regulations may also apply in certain cases.
VDE 0108, PARt 100 – EMERGENCY LIGHtING MODEL BuILDING CODE REGuLAtIONS
See page 260 for symbol legend
249
EB NEA < 0,5 sec
BS
CPS LPS
DS3h≤ 1,0 sec
1,0 lxEn50%5 sec
60 sec100%
GERMAN REGuLAtIONS
Specifications subject to alteration
Pubs and restaurants
Model regulation for places of assembly (MVStättV), June 2005 version
MVStättV applies to the following: Restaurants whose dining area floorspace exceeds 200 square meters; and pubs and discotheques that have standing room and more than 100 square meters of floorspace.
Please note:
the number of persons is to be calculated as follows:
- for table seating: 1 person per square meter of room floorspace
- for seats arranged in rows and for standing room: 2 persons per square meter of room floorspaces
Exceptions:
none
Definition:
In places of assembly an emergency escape lighting system must be installed that allows for safe termination of operations on stages and in performance areas, and safe escape of members of the public and staff, even in case of total failure of general lighting.
Emergency lighting must be provided:
- for staircases, landings, exits and essential corridors
- in assembly rooms as well as in any rooms/areas that are used by visitors such as foyers, cloakrooms, and lavatories
- for stages and performance areas
- in staff rooms larger than 20 square meters of floorspace, office rooms excluded
- in rooms that accommodate electrical equipment or technical building systems, as well as in spotlight and projector rooms
- for outdoor places of assembly and sports stadiums that are used after dark
- for safety signs of exits and escape routes
- for illumination of steps
In assembly rooms that are darkened for operation, on stages and performance areas, non-maintained safety lighting must be installed. Exits, corridors and stairs in these assembly rooms must be recognizable while these rooms are darkened, irrespective of the remaining emergency lighting. An illumination of stairs is not required for the corridors of assembly rooms containing mobile chairs, as well as for sports stadiums with emergency lighting.
Restaurants, VDE 0108, Part 100
EN 1838
Important note:
the above are model regulations only. Regional building code regulations may also apply in certain cases.
MODEL BuILDING CODE REGuLAtIONS VDE 0108, PARt 100 – EMERGENCY LIGHtING
See page 260 for symbol legend
250
EB NEA < 15 sec
1,0 lx
BS
CPS LPS
En50%5 sec
60 sec100%
DS8hje nach Panikrisiko oder Gefährdungsbeurteilung
1 - 15 sec
GERMAN REGuLAtIONS
Specifications subject to alteration
Multi-storey buildings
Model Directive concerning the construction, operation and maintenance of multi-storey buildings (M-HHR), April 2008 version
Special requirements and variances pursuant to article 51, section 1 of the Model Building Code (MBO) for the construction and operation of multi-storey buildings (paragraph 2, section 4, no. 1 of MBO) are provided herein.
Multi-storey buildings are buildings whose height exceeds 22 meters.
Exceptions:
Emergency escape lighting time can be reduced to 3 hours if the lighting is timer-controlled and switched via master lighting switches.
Definition:
Emergency escape lighting
the emergency escape lighting system in multi-storey buildings must automatically switch on in the event of a general lighting failure.
Emergency escape lighting must be provided:
- on escape routes
- in front of lifts
- for safety signs on escape routes
Multi-storey building, VDE 0108, Part 100
EN 1838
Important note:
the above are model regulations only. Regional building code regulations may also apply in certain cases.
VDE 0108, PARt 100 – EMERGENCY LIGHtING MODEL BuILDING CODE REGuLAtIONS
See page 260 for symbol legend
251
EB NEA < 15 sec
1,0 lx
BS
CPS LPS
En50%5 sec
60 sec100%
DS8hje nach Panikrisiko oder Gefährdungsbeurteilung
1 - 15 sec
GERMAN REGuLAtIONS
Specifications subject to alteration
Accomodation facilities and nursing homes
Model regulation regarding the construction, operation and maintenance of accomodation facilities (MBeVO).
the provisions of this regulation apply to accomodation facilities with more than 12 guest beds.
Please note:
Emergency escape lighting time can be reduced to 3 hours if the lighting is timer-controlled and switched via master lighting switches.
Exceptions:
this regulation does not apply to holiday apartments.
Definition:
In accommodation facilities emergency escape lighting must be provided:
- in all essential corridors and staircases
- in rooms and landings between essential staircases and exits
- for safety exit signs
- for steps in essential corridors
Accomodation facilities, VDE 0108, Part 100
EN 1838
Important note:
the above are model regulations only. Regional building code regulations may also apply in certain cases.
MODEL BuILDING CODE REGuLAtIONS VDE 0108, PARt 100 – EMERGENCY LIGHtING
See page 260 for symbol legend
252
EB NEA < 15 sec
BS
CPS LPS
DS3hje nach Panikrisiko oder Gefährdungsbeurteilung
1 - 15 sec
1,0 lxEn50%5 sec
60 sec100%
GERMAN REGuLAtIONS
Specifications subject to alteration
Schools
Model directive regarding building code regulations for schools (MSchulbauR), April 2009 version
this directive applies to requirements pursuant to paragraph 51, section 1 of the Model Building Code (MBO) for general education and vocational schools that are not used solely for adult education classes.
Please note:
Insofar as not otherwise provided by the MSchulbauR directive, the provisions of the MBO building code shall apply. Any workplace safety regulations issued by insurers, trade associations and so on, as well as workplace regulations or regional laws that apply to schools apply.
Exceptions:
this directive does not apply to colleges, universities, academies, adult education centres, music schools, dance schools, driving schools and the like.
Definition:
Emergency escape lighting must be provided in halls that are intersected by escape routes, in essential corridors and staircases as well as in windowless common rooms.
Schools, VDE 0108, Part 100
EN 1838
Important note:
the above are model regulations only. Regional building code regulations may also apply in certain cases.
VDE 0108, PARt 100 – EMERGENCY LIGHtING MODEL BuILDING CODE REGuLAtIONS
See page 260 for symbol legend
253
EB NEA < 15 sec
BS
CPS LPS
DS1h≤ 15 sec
1,0 lxEn50%5 sec
60 sec100%
GERMAN REGuLAtIONS
Specifications subject to alteration
Car-parks
Regulation regarding the construction, operation and maintenance of car-parks (M-GarVO), May 1993 version (as amended by the resolution of 30 May 2008)
An emergency escape lighting system for the illumination of escape routes must be installed in large enclosed car-parks (excluding large single-level car-parks with regular users).
Large car-parks are car-parks with net floorspace exceeding 1,000 square meters.
Exceptions:
none
Definition:
Open car-parks are car-parks (a) with non-closeable openings that (i) lead directly outside and (ii) whose surface accounts for at least one third of the total surface of the facility’s exterior walls; (b) at least two of whose opposing enclosing walls containing such openings are not more than 70 meters apart; and (d) with continuous cross ventilation.
Small open car-parks are small car-parks with non-closeable openings that (i) lead directly outside and (ii) whose surface accounts for at least one third of the total surface of the facility’s exterior walls.
Closed car-parks are car-parks that do not meet the above criteria.
Car-parks, VDE 0108, Part 100
EN 1838
Important note:
the above are model regulations only. Regional building code regulations may also apply in certain cases.
MODEL BuILDING CODE REGuLAtIONS VDE 0108, PARt 100 – EMERGENCY LIGHtING
See page 260 for symbol legend
254
EB NEA < 0,5 sec
BS
CPS LPS
DS3h≤ 1,0 sec
1,0 lxEn50%5 sec
60 sec100%
GERMAN REGuLAtIONS
Specifications subject to alteration
Exhibition places
Model regulation for places of assembly (MVStättV), June 2005 version
Places of assembly with assembly rooms, used for the gathering together of 200 or more persons.
Please note:
the number of persons is to be calculated as follows:
- for table seating: 1 person per square meter of room floorspace
- for seats arranged in rows and for standing room: 2 persons per square meter of room floorspace
Exceptions:
Pursuant to number 3 of the MVStättV (places of assembly regulation), only exhibition rooms of museums are excluded from the scope of application.
the above regulation applies, however, to museums with other rooms of assembly pursuant to article 2, no. 3 (i.g. foyer, discussion rooms, cafeteria or the like) which fall within the scope of article 1.
Definition:
In places of assembly an emergency escape lighting system must be installed that allows for safe termination of operations on stages and in performance areas, and safe escape of members of the public and staff, even in case of total failure of general lighting.
Emergency escape lighting must be provided:
- for staircases, landings, exits and essential corridors
- in assembly rooms as well as in any rooms/areas that are used by visitors such as foyers, cloakrooms, and lavatories
- for stages and performance areas
- in staff rooms larger than 20 square meters of floorspace, office rooms excluded
- in rooms that accommodate electrical equipment or technical building systems, as well as in spotlight and projector rooms
- for outdoor places of assembly and sports stadiums that are used after dark
- for safety signs of exits and escape routes
- for illumination of steps
In assembly rooms that are darkened for operation, on stages and performance areas, non-maintained safety lighting must be installed. Exits, corridors and stairs in these assembly rooms must be recognizable while these rooms are darkened, irrespective of the remaining emergency lighting. An illumination of stairs is not required for the corridors of assembly rooms containing mobile chairs, as well as for sports stadiums with emergency lighting.
Exhibition places, VDE 0108, Part 100
EN 1838
Important note:
the above are model regulations only. Regional building code regulations may also apply in certain cases.
VDE 0108, PARt 100 – EMERGENCY LIGHtING MODEL BuILDING CODE REGuLAtIONS
See page 260 for symbol legend
255
EB NEA < 0,5 sec
BS
CPS LPS
DS3h≤ 1,0 sec
1,0 lxEn50%5 sec
60 sec100%
3,0 lx
GERMAN REGuLAtIONS
Specifications subject to alteration
Stages
Model regulation for places of assembly (MVStättV), June 2005 version)
Places of assembly with assembly rooms, used for the gathering together of 200 or more persons.
Exceptions:
Performance spaces with less than 20 square meters of floorspace are not classified as performance areas.
Definition:
In places of assembly an emergency escape lighting system must be installed that allows for safe termination of operations on stages and in performance areas, and safe escape of members of the public and staff, even in case of total failure of general lighting.
Emergency escape lighting must be provided:
- for staircases, landings, exits and essential corridors
- in assembly rooms as well as in any rooms/areas that are used by visitors such as foyers, cloakrooms, and lavatories
- for stages and performance areas
- in staff rooms larger than 20 square meters of floorspace, office rooms excluded
- in rooms that accommodate electrical equipment or technical building systems, as well as in spotlight and projector rooms
- for outdoor places of assembly and sports stadiums that are used after dark
- for safety signs of exits and escape routes
- for illumination of steps
In assembly rooms that are darkened for operation, on stages and performance areas, non-maintained safety lighting must be installed. Exits, corridors and stairs in these assembly rooms must be recognizable while these rooms are darkened, irrespective of the remaining emergency lighting. An illumination of stairs is not required for the corridors of assembly rooms containing mobile chairs, as well as for sports stadiums with emergency lighting.
Stages, VDE 0108, Part 100
EN 1838
Bühnen VDE 0108 Teil 100
Important note:
the above are model regulations only. Regional building code regulations may also apply in certain cases.
MODEL BuILDING CODE REGuLAtIONS VDE 0108, PARt 100 – EMERGENCY LIGHtING
See page 260 for symbol legend
256
EB NEA < 0,5 sec
1,0 lx
BS
CPS LPS
En50%5 sec
60 sec100%
DS3h≤ 1,0 sec
GERMAN REGuLAtIONS
Specifications subject to alteration
Points of sale
Model regulation regarding the construction, operation and maintenance of retail outlets (MVkVO)
Shops and shopping malls with more than 2,000 square meters of floorspace
Exceptions:
none
Definition:
In retail outlets, emergency escape lighting must be provided:
- inside shops
- in staircases, landings and shopping streets
- in corridors that are essential for customers
- in staff rooms
- in lavatories with more than 50 square meters of floorspace
- in rooms that accommodate electrical equipment or technical building systems
- for safety exit signs and illumination of steps.
Points of sale, VDE 0108, Part 100
EN 1838
Important note:
the above are model regulations only. Regional building code regulations may also apply in certain cases.
VDE 0108, PARt 100 – EMERGENCY LIGHtING MODEL BuILDING CODE REGuLAtIONS
See page 260 for symbol legend
257
EB ≤ 15 sec
1,0 lx
BS
CPS LPS
En50%5 sec
60 sec100%
BS1h≤ 15 sec
GERMAN REGuLAtIONS
Specifications subject to alteration
Workplaces
Workplace directive concerning emergency escape lighting (ASR 7/4)
- Escape routes in working areas and storerooms with more than 2,000 square meters of floorspace
- Escape routes in working areas and staff rooms whose floors are more then 22 meters above the ground
- Escape routes located in the following types of areas with more than 100 square meters of floorspace: working areas without windows, skylight or the like; rooms that are kept dark for operational purposes
- Escape routes located in the following types of areas with more than 30 but less than 100 square meters of floorspace: in working areas without windows, skylight or the like; rooms that are kept dark for operational purposes. For such escape routes, luminaires that can be seen from any point are to be installed at all exits.
- Escape routes in potentially explosive or toxic workplaces, as well as in workplaces in which non-sealed radioactive materials are handled, with more than 100 square meters of floorspace
- Escape routes in potentially explosive or toxic working places, as well as in workplaces in which non-sealed radioactive materials are handled, with more than 30 and less than 100 square meters of floorspace. For such escape routes, luminaires that can be seen from any point are to be installed at all exits.
- For escape routes in laboratories with more than 600 square meters of floorspace and where workers are exposed to specific hazards
- For escape routes in laboratories with more than 30 and less than 600 square meters of floorspace and where workers are exposed to specific hazards. For such escape routes, luminaires that can be seen from any point are to be installed at all exits.
Exceptions:
none
Definition:
Escape route lighting
Escape route lighting must allow for safe evacuation by providing sufficient illumination for escape routes and signs.
Illuminance
Escape routes must be lit with a minimum of 1 lux. this value is that measured at the end of the luminaire’s operating time on the horizontal plane located 0.2 meters above floor level or the stairs.
Minimum operating time: 1 hour.
Workplaces, VDE 0108, Part 100
EN 1838
Important note:
the above are model regulations only. Regional building code regulations may also apply in certain cases.
MODEL BuILDING CODE REGuLAtIONS VDE 0108, PARt 100 – EMERGENCY LIGHtING
See page 260 for symbol legend
258
EB NEA < 0,5 sec
E = 0,1 x Enmindestens aber 15 lx
BS
CPS LPS
En50%5 sec
60 sec100%
DSZeitraum der Gefährdung
≤ 0,5 sec
GERMAN REGuLAtIONS
Specifications subject to alteration
High risk task areas
Workplace directive concerning emergency escape lighting (ASR 7/4)
High risk task area lighting must be provided in places where staff or third parties are exposed to specific hazards, or where accidents are very likely to occur in the event of a general lighting failure.
Please note:
the emergency escape luminaires for particularly hazardous workplaces have to be installed in such a way that the required illuminance values are achieved within the entire area of hazardous risk.
Definition:
General
the technical specifications for high risk task area lighting are determined by the type of activity and room involved.
Illuminance
the illuminance values of high risk task area lighting are determined by nominal illuminance (En) pursuant to workplace directive “ASR 7/3: Artificial lighting” for each type of activity and room.
The illuminance of high risk task area lighting must be E = 0.1 x En, however not less than 15 lux.
this illuminance must continue for the duration of the risk, subject to a one hour minimum.
Delay on startup
the maximum delay on startup for high risk task area lighting is 0.5 seconds.
High-risk workplaces, VDE 0108, Part 100
EN 1838
Important note:
the above are model regulations only. Regional building code regulations may also apply in certain cases.
VDE 0108, PARt 100 – EMERGENCY LIGHtING MODEL BuILDING CODE REGuLAtIONS
See page 260 for symbol legend
259
EB NEA < 0,5 sec
1,0 lx
BS
CPS LPS
En50%5 sec
60 sec100%
DS3h≤ 1,0 sec
GERMAN REGuLAtIONS
Specifications subject to alteration
Airports / railway stations
Please note:
For above-ground railway station areas a rated duration of 1 hour may be admissible, depending on the evacuation plan.
Exceptions:
none
Definition:
none
Airports / railway stations, VDE 0108, Part 100
EN 1838
Important note:
the above are model regulations only. Regional building code regulations may also apply in certain cases.
MODEL BuILDING CODE REGuLAtIONS VDE 0108, PARt 100 – EMERGENCY LIGHtING
See page 260 for symbol legend
260
GBS
BS
1h
DS
≤ 0,5 sec
3h
8h
≤ 1,0 sec
Zeitraum der Gefährdung
BS
≤ 15 sec
je nach Panikrisiko oder Gefährdungsbeurteilung
1 - 15 secEB
0,5 lx
NEA < 0,5 sec
1,0 lx
NEA < 0 sec
CPS
GDS
3,0 lx
NEA < 15 sec
LPS
En50%5 sec
60 sec100%
E = 0,1 x Enmindestens aber 15 lx
GERMAN REGuLAtIONS
Specifications subject to alteration
SYMBOL LEGEND VDE 0108, PARt 100
Switching time ≤ 0.5 sec
Switching time ≤ 1.0 sec
Switching time ≤ 15 sec
Switching time 1 - 15 sec (depending on panic risk or danger level)
Rated duration: 1 hour
Rated duration: 3 hours
Rated duration: 8 hours
Rated duration: (duration of danger)
Escape route sign, non-maintained
Escape route sign, maintained
Emergency escape luminaire, non-maintained
Switched non-maintained
Switched maintained
Central battery systems
Group battery systems
Single battery systems
Emergency power supply system < 0.5 sec
Emergency power supply system < 0 sec
Emergency power supply system < 15 sec
Nominal illuminance 0.5 lx
Nominal illuminance 1.0 lx
Nominal illuminance 3.0 lx
Nominal illuminance 50% Nominal illuminance 100%
> 10% of nominal illuminance min. E > 15 lx
261
GERMAN REGuLAtIONS
Specifications subject to alteration
Costs for weekly tests
LuminairesBattery/Batteries
Systems
During the planning phase, cost optimization proce-dures can be applied to
system purchases.
Luminaire installationSet-up
(CPS/LPS)
Purchase of easy to install luminaires
Mixed operation techno-logy obviates the need for
cabling
Power supplyMaintenanceSpare parts
State of the art LED techno-logy reduces energy costs
and battery capacities
use of lamps with a long service life reduces repair
and spare parts costs
Automatic testing systemsreduce labour costs
SAFETY LIGHTING COSTS
COST SAVINGS OPTIONS
Purchase costs
Purchase costs
Installation costs
Installation costs
Operating costs
Operating costs
Luminaires with a test button
Luminaires with an automatic self-test function
Luminaires with an automatic self-test function
and testing system (DALI, MWEBplus, MultiDigit®)
tasks Employee must test all luminaires once a week, which requires a lot of time. Ceiling mounted luminaires can be tested only using a ladder.
Employee must only control all luminaires once a week.
Employee receives testing results at a central workstation or via e-mail.
time required 7 minutes per luminaire 3 minutes per luminaire total of 5 minutes
Hourly labour costs 10.00 € 10.00 € 10.00 €
System with: 30 luminaires 30 luminaires 30 luminaires
time required for weekly function test
210 min. 90 min. 5 min.
Costs for weekly function test 35.00 € 15.00 € 0.83 €
Annual costs 1,820.00 € 780.00 € 43.33 €
262
ga
a
gb
a
GERMAN REGuLAtIONS
Specifications subject to alteration
Design of escape signs
square rectangular b = 2 x a
Contrast colour (white)Safety colour (green)
Luminance
Luminance during mains-power operation in accordance with DIN 4844-Part 1 (05/2005): average luminance of contrast colour: min. 500 cd/square meter
Escape route / Emergency exitDirectional arrow
Design of escape signs
Escape signs are always to be composed of a directional arrow and the escape route/ exit symbol.
Safety and health signs
1. Scope of application
these safety provisions apply to safety and health signs at work.
2. Definitions
Escape sign
means a safety sign indicating an escape route, emergency exit, first-aid station, or the route to such facilities.
3. Escape routes
Escape routes are clearly marked routes that allow (a) employees to evacuate a facility; and (b) rescue and evacuation of injured employees or employees exposed to hazards.
4. Visibility
- Safety signs must be installed in such a way that they are clearly visible and securely attached at all times. they must be made of materials that are resistant to the environmental factors.
- If a safety sign is installed at a location with inadequate natural light, the sign’s visibility is to be ensured via artificial lighting.
5. Maintenance
the employer is responsible for maintenance of workplace health and safety signs.
6. Testing
- the employer is to ensure that all health and safety signs are inspected at two years intervals at a minimum.
- the employer is to ensure that all technical elements (such as luminaires) are tested at least once a year by an experienced technician.
Directional arrow Escape route / Emergency exit
Emergency exit
DIN 4844, PARt 1 AND PARt 2 BGV A 8
263
GERMAN REGuLAtIONS
Specifications subject to alteration
Scope
this standard applies to, among others, the installation of electrical and safety systems in the following types of structures that are used for gatherings of people:
- Places of assembly
- Exhibition halls
- theatres and cinemas
- Sports stadiums
- Points of sale
- Restaurants
- Nursing homes
- Accomodation facilities
- Schools
- Car-parks
- underground car-parks
- Swimming pools
- Airports
- Railway stations
- Multi-storey buildings
- Workplaces
Power sources
DC circuits must be protected against overload by a 2-pole fuse
Connecting diagrams
A detailed connecting diagram for the electric system must be available near the main distribution board of the backup power supply and is to indicate the following:
- Safety circuits (including monitoring systems)
- type and number of loads per circuit
- Load of each single circuit
- total system load
Site plans and information concerning each single electric load as well as its location are also to be available. Such plans are to indicate the following:
- Exact position of all electrical operating locations
- Exact position of distributors, cables and routes (except for final circuits)
- All safety related electrical loads and circuit names
- Safety related control and monitoring units
Cross sections
Final circuits must have a cross section of min. 1.5 mm².
Displayed information for safety monitoring purposes
For reasons of safety, system operation is to be monitored and the following information is to be displayed:
- System ready for operation
- Battery mode
- System error
Test logs
the facility vendor is to provide the facility operator with log books where all test results are to be recorded and stored for a period of 4 years.
Electronic log books from a DIN EN 62034 conformant automatic testing system are also regarded as valid log books if the test results can be archived for a period of 4 years and displayed or printed out.
Electric circuits
Safety circuits must be physically isolated from other cable routes and may pass through fire risk areas – but not explosion risk areas - if they are fire resistant.
However, conducting safety circuits through fire risk areas should be avoided wherever possible.
Power sources
If only one backup power source is available it is not to be used for any other purpose.
Absence of feedback
Errors and failures in any safety system are not to affect the loads of any other system.
VDE 0100, PARt 718 – BuILDINGS FOR GAtHERINGS OF PEOPLE
VDE 0100, PARt 560 – SYStEMS WItH NOMINAL VOLtAGES OF uP tO 1 000 V
264
GERMAN REGuLAtIONS
Specifications subject to alteration
Regional German building codes
Landesbauordnung (MBO)
- (Model) School building directive 07/1998
- (Model) Places of assembly regulation 06/2005
- (Model) Points of sale regulation 09/1995
- (Model) Directive for multi-storey buildings 04/2008
- (Model) Car-parks regulation 07/1997
- (Model) Accomodation facilities regulation 12/2000
- (Model) Directive concerning temporary buildings 05/2007
- ...
Workplace health and safety regulations
Workplace regulation
Workplace directive
Trade and Industry Regulation
Regulations for the prevention of accidents (BGV A8, BGR 216, BGR 131 etc)
1. Scope
this directive applies to
- Wiring systems in the following locations: essential stairwells; landings and spaces that connect essential stairwells and exits; essential corridors, excluding open corridors in front of external walls,
- Passing cables through walls, ceilings and the like,
- Fire protection for electrical wiring systems.
2. Definitions
Wiring systems are composed of electric cables and/or conduits and the relevant fittings, connections, monitoring and control systems, power supplies, distributors and insulating material for cables, including the attachment hardware and coatings used for the wires/conduits.
Fiberoptic cables and electric cables are classified as electric wires.
3. Fire resistance
Fire-protected distributors for electrical wiring systems pursuant to section 5.3 of directive (M)LAR must:
- be located in suitable spaces that are not used for other purposes and that are separated from other rooms by walls, ceilings or doors that are adequately fire-protected and – apart from the doors – made of incombustible materials
- be kept in separate housings with a certified fire-resistance duration rating; or
- be enclosed in components (including the enclosures) that exhibit adequate fire resistance duration and that are composed of incombustible materials (excluding the enclosures); operability of the distributor’s electric components must be ensured in the event of fire for the entire fire resistance duration.
the fire resistance duration must be no less than 30 minutes for:
- Emergency escape lighting systems, to the exclusion of wiring systems that supply power to emergency escape lighting within only one fire compartment of one storey or within one stairwell; maximum floorspace per fire compartment: 1,600 square meters.
BuILDING CODE
WIRING SYStEMS DIRECtIVE ((M) LAR) (11/2005)
REQUIREMENT
Compliance with generally accepted standards is required
Building permit
265
GERMAN REGuLAtIONS
Specifications subject to alteration
New „Technical rules for workplaces“
ASR A1.3 Safety and health signs (04/2007)
ASR A2.3 Escape routes, emergency exits, escape and rescue plan (08/2007)
ASR A3.4/3 Emergency escape lighting, optical safety guidance systems (05/2009)
the regulation titled BGR 216: Optische Sicherheitsleitsysteme (einschließlich Sicherheitsbeleuchtung) (optical safety guidance systems (including safety lighting)), will remain in force until 31 August, 2010, along with the regulation titled ASR A3.4/3. In May 2009, the old workplace directive titled ASR 7/4: Sicherheitsbeleuchtung (emergency escape lighting) was superseded by the regulation titled ASR A3.4/3.
ASR A1.3
Contents
1. Objectives
2. Scope
3. Definitions
4. General
5. Signs
6. Escape and rescue plans
7. Labelling of containers and conduits containing dangerous substances Annex(es)
Objectives
this directive ASR A1.3 lays down the requirements for safety and health signs at workplaces. Pursuant to article 3 of the workplace regulation titled Arbeitsstättenverordnung and section 1.3 of the appendix thereof, safety and health signs are to be used in order to avert workplace safety and health risks.
Scope
the workplace regulation Arbeitsstättenverordnung implements Eu Directive 92/58/EEC on the minimum requirements for the provision of safety and/or health signs at work.
Escape and rescue route plan
Directional arrow Escape route / Emergency exit
WORKPLACE DIRECtIVES
266
GERMAN REGuLAtIONS
Specifications subject to alteration
ASR 2.3 Escape routes, emergency exits, escape and rescue plan
Contents
1. Objectives
2. Scope
3. Definitions
4. General
5. Design, dimensions
6. Application
7. Signs
8. Emergency escape lighting
9. Escape and rescue plan
Objectives
this workplace directive lays down the requirements (pursuant to article 4, paragraph 4, and item 2.3 of the appendix to the workplace regulation titled Arbeitsstättenverordnung) concerning (a) the installation and maintenance of escape routes and emergency exits; and (b) escape and rescue plans, with a view to ensuring safe workplace evacuation in the event of danger.
Scope
this workplace directive applies to the installation and maintenance of escape routes and emergency exits in buildings and similar structures to which employees have access during work, as well as to the elaboration of escape and rescue plans and related exercises. Such routes and plans are to be elaborated in a manner that allows for the possibility that outside parties may be present during an emergency.
This workplace rule does not apply
- to installation and maintenance of the following:
a) outdoor workplaces that are not enclosed on all sides
b) building construction sites
c) areas in any structures that are occupied solely for maintenance and inspection purposes
d) areas in any structure where handicapped people are employed
- to leaving work equipment behind in the event of danger within the meaning of article 2, paragraph 1, of the Industrial Safety and health regulation (Betriebssicherheitsverordnung).
In comparable situations, this directive may be applied to any excluded areas. If not, specific measures have to be taken to ensure employee safety in the event of danger.
Signs
Escape routes, emergency exit and door signs are to conform with the directive titled ASR A1.3.
Emergency escape lighting
Section 8 of the directive titled ASR A2.3 (concerning escape routes, emergency exits, escape and rescue plans) defines the conditions under which emergency escape lighting is required for escape routes.
In the scenarios described in the said section 8, the primary and possibly also the secondary escape route are to be equipped with emergency escape lighting.
Escape routes are to be equipped with emergency escape lighting insofar as safe evacuation of the workplace in the event of a general lighting failure cannot be guaranteed.
Emergency escape lighting may be required for example in workplaces that exhibit the following characteristics (among others):
- Workplaces with a large number of employees or that are located in tall buildings; workplaces with high risk areas or unclear escape routes
- Workplaces used by persons who are unfamiliar with the place
- Workplaces where large spaces such as open-plan offices or retail spaces must be traversed during an evacuation
- Workplaces with no natural light, such as basement rooms.
Escape and rescue plan
the employer is to devise a suitable escape and rescue plan for those areas of the workplace whose location, dimensions and/or type necessitate the use of such a plan.
Escape and rescue plans must be up to date, easy to understand and read, and must be elaborated using standard safety colours and symbols.
For requirements concerning escape and rescue plans, see the regulation titled ASR A1.3.
Escape and rescue plans are to incorporate graphic elements indicating the following:
- Site plan or parts thereof
- Escape and rescue routes
- First-aid posts
- Fire fighting equipment
- Assembly point location
- Point of location of the user (“you are here” indication)
the escape and rescue plans is to be displayed in sufficient number in suitable areas of the workplace.
WORKPLACE DIRECtIVES
267
GERMAN REGuLAtIONS
Specifications subject to alteration
ASR 2.3 Escape routes, emergency exits, escape and rescue plan
Section 8 of the directive titled ASR A2.3 defines the conditions under which emergency escape lighting is required for escape routes.
In the scenarios described in this section of the directive, the primary and possibly also the secondary escape route are to be equipped with emergency escape lighting.
ASR A3.4/3 Emergency escape lighting, optical safety guidance systems
Contents
1. Objectives
2. Scope
3. Definitions
4. Emergency escape lighting
5. Optical safety guidance systems
6. Operation, maintenance and testing
7. Supplementary requirements for building sites
Objectives
this workplace directive specifies the requirements concerning the installation and maintenance of emergency escape lighting and optical safety guidance systems pursuant to article 3, paragraph 1, and article 4, paragraphs 3 and 4, and notably item 2.3 paragraph 1 and item 3.4 paragraph 3 of the appendix to the workplace regulation titled Arbeitsstättenverordnung.
Scope
this workplace directive (a) applies to the installation and maintenance of emergency escape lighting and optical safety guidance systems in workplaces; (b) cites examples of types of workplaces which may require emergency escape lighting or optical safety guidance systems: and (c) lays down technical specifications for emergency escape lighting and optical safety guidance systems and the use thereof.
Emergency escape lighting
4.1 Escape route lighting
Section 8 of the directive titled ASR A2.3 defines the conditions under which emergency escape lighting is required for escape routes.
In the scenarios described in this section of the directive, the primary and possibly also the secondary escape route are to be equipped with emergency escape lighting.
4.2 High risk task area lighting
In workplaces where accidents are likely to occur in the event of a general lighting failure, the required illuminace of the emergency escape lighting is to be reached within 0.5 seconds and must continue at least for the duration of the risk.
Escape routes are to be equipped with emergency escape lighting insofar as safe evacuation of the workplace in the event of a general lighting failure cannot be guaranteed.
(ASR A2.3 Paragraph. 8).
Workplaces where employee health and safety are at risk in the event of a general lighting failure and where emergency escape lighting is required include the following among others:
High-risk workplaces:
- Laboratories
- Rooms that are darkened for operation
- Rooms that accommodate electrical equipment or technical building systems
- Workplaces with a large number of employees
- Workplaces that are located in tall buildings
- Workplaces with high-risk areas
- Workplaces with unclear escape routes
- Rooms or areas used by persons who are unfamiliar with the place
- Workplaces where large spaces such as open-plan offices must be traversed during an evacuation
- Rooms with no natural light
- Working areas where long trailing equipment or machines are used
- Areas containing control units for systems that are subject to continuous monitoring (e.g. control rooms)
- Workplaces with immersion baths containing heated liquids, casting pits or acid baths
- Building construction sites
Directive ASR A3.4/3 applies in many cases to building construction sites because of the high risk for persons.
Emergency escape lighting is essential in cases where there is not sufficient natural light to light escape routes so as to allow for safe workplace evacuation.
Building construction sites used after dark
the illuminance of emergency escape lighting for escape routes must be at least 1 lux, with a uniformity of less than 40:1.
Escape route illumination
Identification of escape routes via the relevant signs
WORKPLACE DIRECtIVES
268 Specifications subject to alteration
ESCAPE LIGHtING PLANNING
Power supply cable
max. 20 luminaires or 815 VAmax. 20 luminaires or 815 VAmax. 20 luminaires or 815 VAmax. 20 luminaires or 815 VA
PLANNING
Important issues:
1. Is safety lighting required? Building permit, building codes and regulations, work safety laws, workplace regulations, etc.
2. Wich type of self-contained or central battery system (CPS / LPS) is to be used?
See VDE 0108, Part 100, table A1 (see table on page 246)
3. Which is the required nominal operating time?
See VDE 0108, Part 100, table A1 (see table on page 246)
4. Escape and rescue routes plan the escape and rescue route plan indicates all mandatory escape routes and emergency exits (in the absence of such a plan, escape routes and emergency exits are to be indicated by the plannner or architect).
5. LuminairesSee EN 1838 for detailed information concerning the installation of safety signs. the number of emergency escape luminaires is to be determined using the spacing table (Leuchtenabstandstabelle) or a lighting calculation formula.
The above ALSO applies to the planning process for a single-battery system!
Potencia y circuitos
6. Capacity of all luminaires = total capacity the battery aging factor must be factored in. We recommend that a 25% aging factor be applied.
7. Total capacity, including the aging factor (loss in capacity) = battery capacity
See table on page 125, where ventilation cross sections are indicated as well.
8. Number of fire compartmentsConsult your planner or architect.Fire compartment dimensions in accordance with directive MLAR (exceptions are allowed in some regions).
9. Number of circuits per fire compartment=> mixed operation => 2 circuits per fire compartment at a minimum => standard operation => 4 circuits per fire compartment at a minimum Important note: Maximum no. of luminaires per circuit: 20, Maximum circuit load: 815 VA !
10. Number of circuits divided by 4 = number of circuit modules
11. Sub-stationsFor calculating the number of circuits and modules per sub-station, the same calculation system that is used for central battery systems circuits calculation is to be applied.
269Specifications subject to alteration
ESCAPE LIGHtING PLANNING
PLANNING
Fire compartment 1 max. 1,600 square meters
Fire compartment 1 max. 1,600 square meters
Fire compartment 2 max. 1,600 square meters
Fire compartment 2 max. 1,600 square meters
E 30 Junction box
E 30
EIB BuS
F 90
E 30 Junction box
NYM to distributor in accordance with LAR
E 30 Power supply cable E 30
fused junction box
Fire compartment 3 max. 1,600 square meters
Fire compartment 3 max. 1,600 square meters
E 30
EIB BuS
F 90
For sub-stations planning, please note:
Active star network
Please note that for this type of network an output in the CPU must be provided for each sub-station.
Linear network
Please note that for this type of network E30 junction boxes are to be provided for each fire compartment.
E 30 junction box
Installation example
270
Exhibition stand emergency lighting light+building 2010
271
Appendix
Service 272 - 273
EVG symbol 274
LED symbol 275
Catalogue number codes 276
Motifs and lettering for emergency luminaires 277
Motifs and lettering for luminaire signs 278 - 279
Lamps 280
Terms of conditions of sale and delivery 281
Catalogue number index 282 - 286
Alphabetical index 287 - 288
Technical support 289
After Sales Service 289
Contact for emergency lighting 289
272
SErViCE
Specifications subject to alteration
Abbreviations
L Lengh
B Width
H Height
D Diameter
LP Pendant length
AL Extension
DA recess opening (width x length or Ø)
HE Luminaire installation height
Luminaire with Edison lampholder
EVG electronic ballast
BS non-maintained
DS maintained
GDS switched maintained
TLS staircase light circuit
LPS Low Power Supply
CPS Central Power Supply
NEA Emergency power supply system
EPS Emergency power supply system
SK Electric circuit
IOM in/Out module
Protection classes
Protection class I
Luminaires for connection to a protective conductor provided on site. The protective conductor terminal is marked . in case of malfunction: Protection through power supply switch-off by overcurrent protection device.
Protection class II
Base insulation protects against direct contact. in case of mal-function: Additional or reinforced insulation protects against indirect contact.Many protection class i luminaires are also available with pro-tection class ii on request.
Protection class III
Luminaires for connection to safety extra-low voltage (SELV, max. 50 V AC), e.g. using safety transformers or other sources of voltage with comparable safety features. in case of malfunction: Protection through effectively harmless volt-age. Mains connection via luminaire equipment with dual or reinforced insulation on the mains side.
The information relating to the resistance of our luminaires to solid objects and water is based on EN 60598/VDE 0711.
Specifications subject to alteration.
Types of protection according to EN 60598/VDE 0711
1st digit: Protection against solid objects
iP 2X Protection against penetration of solid objects
> 12.5 mm
iP 3X Protection against penetration of solid objects
> 2.5 mm
iP 4X Protection against penetration of solid objects
> 1 mm
iP 5X Protection against dust penetration
iP 6X Dust-proof
2nd digit: Protection against water
iP X1 Luminaires are protected against water drops
(vertically falling drops of water)
iP X2 Luminaires are protected against water drops
(drops of water up to 15° from the vertical)
iP X3 Luminaires are protected against rain
iP X4 Luminaires are protected against water sprays
iP X5 Luminaires are protected against water jets
iP X6 Luminaires are protected against rough sea or
heavy jets of water
iP X7 Protection against temporary immersion
iP X8 Protection against continuous immersion
The type of protection indicated for surface mounted, recessed,
pole or pendant luminaires only applies for the defined and/or
permitted type of luminaire installation.
_ _ m
Electric circuit identification labels | VDE 0108/DIN 56932A sheet of circuit identification labels in accordance with DiN 56932; self-adhesive white plastic foils with red silk screen printing for application on plain surfaces. One sheet contains 12 circuit identification labels; circuit numbers 001 to 150 are available from stock. Please indicate circuit numbers when placing your order, e.g. 99350/017!
Article number99350
Electric circuit identification labels | VDE 0108/DIN 56932Light plastic plate for application on roughcast or any other irregular surfaces to be used as support for circuit identification labels 99350.
Article number99351
Circuit identification labels, blank A sheet of circuit identification labels in accordance with DiN 56932; self-adhesive white plastic foils with red silk screen printing for application on plain surfaces. One sheet contains 12 circuit identification labels for application of personalized lettering;
Article number99350.1
273
SErViCE
Specifications subject to alteration
Ballast
Our luminaires are mainly fitted with low-loss ballast. They are designed for 230 V/50 Hz (equipment with other specifications is available on request).
Luminaires with electronic ballast are indicated by the code at the end of the catalogue number, e.g. .79 or have their own separate order number with explanatory text.
Electrotechnical variants and additionsCodes are marked by a two-digit suffix separated by a point at the end of
the catalogue number.
Code .03
Version with automatic self-test function and feedback to PZ 50
Code .04
Version with automatic self-test function and feedback to MultiDigit® and MWEBplus
DALI Code .07
Version with automatic self-test function and feedback to DALi unit
EVG Code .79
Versions with electronic ballast
Control 1 Code .71
Monitoring module for GV 1500 and rZBbasic
TWIN-Control Code .72
Monitoring module for mixed operation via switch for GV 1500 and rZBeasy 202. 3 different switching types can be switched and operated contemporaneously in one circuit.
SINGLE-Control Code .81
Monitoring module for LUXiFAir and LUXiFAirlight
DUO-Control Code .82
Monitoring module for mixed operation via switch for LUXiFAir and LUXiFAirlight
General information
Use of emergency lighting modules
The distances between EB and emergency lighting module must be observed
as longer cable lengths might impair the function.
We recommend:
Distance EB <-> Emergency lighting module: 0.5 m
Distance LLB <-> Emergency lighting module: 2.0 m
Electrotechnical safetyWe guarantee that we have manufactured and tested all of the luminaires in this catalogue carefully in accordance with international standard EN 60598 (VDE 0711).Special luminaires are manufactured in accordance with this standard.
Safety marks
The ENEC mark is a European test and certification mark for luminaires and electrical luminaire components.
Luminaires bearing this mark can be mounted directly onto normally inflammable surfaces (in accordance with EN 60598-1).
Luminaires bearing this mark have a limited surface temperature and are suitable for premises where dust or fibres can create a fire risk.
Luminaires bearing this mark are suitable for mounting on or in furniture made of materials with unknown properties; this applies, in particular to flammability.
Luminaires marked with the “ball impact protection” symbol are suitable for use in sports facilities. They are manufactured in accordance with the test conditions defined in VDE 0710.
Luminaires marked “ta 15°C” are designed for ambient temperatures of 15°C and are also suitable for use outdoors.
The CE mark is not a safety mark. it indicates that the product complies with European Union directives.
Symbol explanations
Luminaires for escape route identification
Luminaires for escape route illumination
Sign for luminaires with Edison lampholder
ta
274
SErViCE
Specifications subject to alteration
LuminAirES for fLuorEScEnt LAmPS with
ELECTrONIC BALLAST
EBs enhance the lighting quality
Quick, silent and flicker-free start
Constant, steady light
No flickering electrodes
No stroboscope effects
Dimmable (dimmable EB)
Controllability, option for integration into control systems
Automatic shutoff of defective lamps (no flickering)
Automatic restart following lamp change
EBs save energy and costs
Low loss performance by EBs
Low system power intake
High system light yield
Longer (30-50%) service life of lamps
Longer lamp replacement intervals
Elimination of starters and capacitors
Low heat generation
Gentle warm start and high switching capacity of lamps
Suitable as emergency lighting
The „lamp plus EB“ system has a considerably reduced power intake and generates significantly less heat. EBs themselves generate little heat, thus reducing climate control measures – resulting in reduced operating costs for the air conditioning system.
The service life of EB-operated lamps increases by 30-50 percent as a result of the reduced load on the lamp and electrodes. A three-band fluorescent lamp burns for 8,000 hours on an LLB compared to 14,500 operating hours on an EB.
in addition to limiting the current, EBs also perform the task of starting and act as compensation condensers. Defective lamps are switched off auto-matically and do not flicker. Lamps are re-started automatically following replacement.
EBs start the lamps quickly, silently and without any flickering.
A warm start (pre-heated electrodes) protects the lamp and prolongs its serv-ice life. EBs developed specially for three-band, 16 mm diameter fluorescent lamps are equipped with cut-off technology that switches the coil heater off if permitted by the lamp operation. This increases the service life of the lamp by another 20 percent.
in HF operation, the lamp voltage is smoother. Lamps operated on EBs therefore produce constant and steady light, with no flickering electrodes or stroboscope effects generated by moving parts.
EBs are largely immune to voltage and frequency fluctuations. in addition, since most of them run on direct current, they can be switched to battery operation in the event of a power failure and used as emergency lights.
if the EB malfunctions, it automatically disconnects itself from the mains.
ENErGY EFFICIENCY
energy savings (25-30%)longer lamp life (approx. +50%)
ENVIrONMENT
reduced energy consumption (25-30%)
longer lamp life (approx. 50%)less lamp waste (approx. 30%)
SYSTEM
Most EB luminaires are suitable for direct current operation. They
can be connected to the emergency lighting’s group and
central battery systems.
275
SErViCE
Specifications subject to alteration
LED stands for light emitting diode, an electronic semi-conductor component.
LEDs supply constant full-beam immediate light. Unlike incandescent lamps, LEDs do not radiate temperature. They emit light in a narrow spectral range and do not emit any infrared or ultraviolet radiation.
LEDs have a high switching speed.
The luminous flux is determined by the electrical current. As such, we rec-ommend the use of a constant source of current. At the current state of development, the service life exceeds 50,000 hours and is dependent on various factors.
Thanks to LED technology, the luminaire industry can design virtually main-tenance-free luminaires.
in summary, it is safe to say that LEDs will supersede incandescent lamps: Compared with conventional lamps, they consume less energy, generate less heat, are insensitive to shock, have considerably shorter switching times and a long service life.
LuminAirES with
LiGht EmittinG DiodES
ENErGY EFFICIENCY
low power intake
long service life ≥ 50,000 hours
FUTUrE
LEDs are the lamps of the futu-re. Thanks to the numerous
benefits, LED development is progressing at a phenomenal
speed.
rZB offers luminaires fitted with LED lamps for selected areas of
application.
These products can be identified by the symbol:
276 Specifications subject to alteration
EMErGENCy LiGHTiNG | ArTiCLE NUMBEr CODiNG
replace the X of the catalogue number with the desired colour.Example:Article number Article number with with X indication of colour671501.00X 671501.004
within the table• luminaire available with this module– luminaire not available with this module
Please add to the catalogue no., includ-ing the colour code, the code for any optional article (separated by a dot)
.03 for PZ 50
.04 for MultiDigit®
.07 for DALi
Article number Article number with with indication indication of colour of colour + y and indication of optional article671501.004.Y 671501.004.03
H
L B
H
L B
H
LLA
BBA
HE
5-35
3
180
151233
4523Ø4,5
15
15
150
233Ø5
12,5
50
1640
4255
255270
HA
LHE
1-30
H
LA
BL
HA
HE
LA
B
H
132150
210220
130150
200220
Article number Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage PZ 50 (.03)
MultiDigit (.04)
DALi (.07)
rated operat-ing time
Dimensions
671501.00X.y Wall (surface) 14 m - 4 x LED 1 W • • - 3 h L 233, B 40, H 180
671502.00X.y Ceiling (surface) 14 m - 4 x LED 1 W • • - 3 h L 233, B 40, H 184
671518.00X.y Ceiling (recessed) 14 m - 4 x LED 1 W • • - 3 hL 270, B 55, H 100 LA 255 x BA 42, HE 90
671546.12X.y Wall (recessed) (cavity wall) 14 m - 1 x LED 4 W • • - 3 h
L 220, B 2, H 150 LA 210 x BA 132, HE 90
671546.00X.y Wall (recessed) (solid wall) 14 m - 1 x LED 4 W • • - 3 h
L 220, B 2, H 150 LA 200 x BA 130, HE 80
Wall (surface) Ceiling (surface) Ceiling (recessed) Wall (recessed) (cavity wall) Wall (recessed) (solid wall)
Series: LED Halyxx®
Type of protection: IP 40 Protection class: i Viewing distance: 14 m Ceiling thickness: 5-35 mm Wall thickness: 1-30 mm
For escape route identification
Base: aluminium extrusion profile; display panel: highly transparent panel with motifs on one side/both sides.
LED included.
Please specify legend number when ordering!
Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS).
Ballast mains/emergency: EB
Available colours (X): 2 = white (only wall installation) 4 = aluminium, anodised (all variants)
H
L B
H
L B
H
LLA
BBA
HE
5-35
3
180
151233
4523Ø4,5
15
15
150233
Ø5
12,550
1640
4255
255270
HA
LHE
1-30
H
LA
BL
HA
HE
LA
B
H
132150
210220
130150
200220
14 m
277Specifications subject to alteration
Motifs for escape route identification –worKPLAcE LEGiSLAtion
Legends in accordance with UVV BGV A8 and EECr 92/58
Background colour: green
1000 Escape route to the right
1117 Escape route to the upper right
1118 Escape route to the lower right
1001 Escape route to the left
1119 Escape route to the upper left
1120 Escape route to the lower left
1002 Emergency exit, arrow pointing down
1051 Meeting point
1166 Emergency exit, arrow pointing down
1003 Escape route to the right
1113 Escape route to the upper right
1114 Escape route to the lower right
1004 Escape route to the left
1115 Escape route to the upper left
1116 Escape route to the lower left
1005 Emergency exit, arrow pointing down
Motifs for escape route identification –BuiLdinG And worKPLAcE LEGiSLAtion
Legends in accordance with DiN 4844, UVV BGV A8 and EECr 92/58
Background colour: green
2003 Escape route to the right
2113 Escape route to the upper right
2114 Escape route to the lower right
2004 Escape route to the left
2115 Escape route to the upper left
2116 Escape route to the lower left
2005 Emergency exit, arrow pointing down
2006 Emergency exit, arrow pointing up
1051 Meeting point
Please quote the motif numbers when ordering safety luminaires with legends.The size of the legend will be matched to the luminaire that you order.
Luminaires with enclosed escape route motifs are supplied in accordance with DIN 4844, UVV BGV A8 and EECr 92/58 (approved by building and workplace legislation). Please indicate the appropriate symbol numbers if you require delivery of other legends.
The aspect ratios of the symbols for escape route identification comply with DiN 4844 and UVV BGV A8, i.e. square-shaped symbols have an aspect ratio of 1:1 and rectangular symbols of 2:1. in the case of luminaires with different dimensions, the remaining illuminated surfaces will be filled with opal.
EMErGENCy LiGHTiNG | MOTiFS AND LETTEriNG
278 Specifications subject to alteration
LUMiNAirE SiGNS | MOTiFS AND LETTEriNGS
Notes for ordering legends and inscriptions
Please always indicate the motif number or text when ordering luminaire signs with legends or inscriptions. The size of the legend or inscription will be matched to the luminaire that you order.
Motifs
Please indicate motif number, e.g. 1019
Motif combinationsindicate the motif numbers from left to right, separated by a forward slash, e.g. 1019/1013
Letteringirrespective of their syntax, letterings are set in upper case, font: Helvetica regular, e.g. EXIT.
Please clearly order lower case if required, e.g. Lower case: Exit
Other standard fonts: Helvetica Medium and Helvetica Bold. Other fonts are available at extra cost. e.g. Helvetica Medium: Exit, Helvetica Bold: Exit
Lettering comprising several linesPlease specify the number of lines,e.g. two lines: CONGrESS CENTEr
Negative imaging of motifs and letteringQuote the motif number (text or digits) and specify “inverse”, e.g. 1019/inverse
Single coloured motifsAll motifs and lettering are mounted on a standard blue background. Other standard colours available at no extra cost: light blue, green, yellow, orange, red, grey Cover colours: silver, blackBackground colour: white/opalQuote the motif number (text or digits) and required colour(s), e.g. 1019/light blue / 1019/light blue/inverse
Numbersinclude the catalogue number 0001-0999e.g. 0692 / 0003
Motifs for numbers
Background colour: blue (standard)
0001-0999 Numbers
Motifs for direction indicators
Background colour: blue (standard)
1013 Arrow pointing right
1014 Arrow pointing left
1015 Arrow pointing down
1016 Arrow pointing up
1175 Arrow pointing left and up
1176 Arrow pointing left and down
1177 Arrow pointing right and up
1178 Arrow pointing right and down
1163 Angled arrow pointing left and up
1164 Angled arrow pointing right and up
Motifs for general signs
Background colour: blue (standard)
1017 Men‘s toilet
1018 Ladies‘ toilet
1019 Men‘s and Ladies‘ toilet
1021 Disabled toilet
1072 restaurant
1073 Cafeteria
1085 Hotel
1030 Cloakroom
1037 Stairway, up
1038 Stairway, down
1074 Lift
1033 Telephone
Motif No. Description
Special colours and fontsMulticoloured motifs or lettering, customised motifs and special colours or motif/text/number combinations are available at extra cost.
Please do not hesitate to forward your request to our sales team. Provide them with details or even a drawing of the sign. We require a template in either .TiFF or .EPS format (or a hand drawing) in order to manufacture custom motifs.
EXit
Exit
EXIT
EXIT
conGrESScEntEr
692
3
279Specifications subject to alteration
LUMiNAirE SiGNS | MOTiFS AND LETTEriNGS
1026 information
1086 Arrivals
1087 Departures
1088 Baggage drop
1089 Baggage collection
1090 Luggage lockers
1091 Taxi
1184 railway station
1185 Tickets / reservations
1186 Exchange/Bank/Cash dispenser
1187 Customs / Baggage control
1092 Car park
1024 Meeting point
1032 No smoking area
Other motifs or customised designs are available on request. There may be an additional cost.
Motifs for sport facilities
Background colour: blue (standard)
1075 Football
1093 Handball
1094 Volleyball
1095 Bowling
1079 ice hockey
1078 Golf course
1077 Swimming
1076 Gymnastics
1080 Athletics
1096 Ballet
1097 riding
The aspect ratios of the symbols (fire protection and first aid, etc.) comply with the regulations specified in the European Directive (92/58/EEC) „Minimum requirements for the provision of safety and/or health signs at work“, i.e. square-shaped symbols 1:1 and rectangular symbols 2:1. in the case of luminaires with different dimensions, the left and right borders are filled in opal.
Motifs for fire protection facilities
Legends in accordance with DiN 4844 and EECr 92/58Background colour: red
1057 Fire hose
1059 Fire extinguisher
1060 Fire alarm
1061 Direction indicator, right 1062 Direction indicator, left
1063 Direction indicator, straight ahead
Direction indicators only in combination with a symbol for a fire protection facility. Other motifs or custom-ised designs are available on request. There may be an additional cost.
Motifs for first aid facilities
Legends in accordance with DiN 4844 and EECr 92/58Background colour: green
1034 First aid station
1052 Stretcher
1053 Doctor
1054 Emergency telephone
1055 Eye-rinsing facility
1084 Emergency shower
1009 Direction indicator, right 1010 Direction indicator, left
1056 Direction indicator, straight ahead
Direction indicators only in combination with a sym-bol for a first aid facility. Other motifs or customised designs are available on request. There may be an additional cost.
Motifs for prohibition signs
Legends in accordance with DiN 4844 and EECr 92/58 Background colour: white; Symbol: black; Prohibition colour: red
1064 Smoking prohibited
1065 Fire, open flames and smoking prohibited
1179 restricted entry
Other motifs or customised designs are available on request. There may be an additional cost.
Motifs for mandatory signs
Legends in accordance with DiN 4844 and EECr 92/58
Background colour: light blue
1067 Eye protection mandatory
1068 Helmet mandatory
1069 Ear protection mandatory
1070 Protective gloves mandatory
Other motifs or customised designs are available on request. There may be an additional cost.
Legends in accordance with EECr 92/58, and/or DiN
40008 and DiN 25430. Background colour: yellow;
Symbol: black
1162 radioactive materials, ionising radiation
1172 Laser beams
1173 Explosive gases
Other motifs or customised designs are available on request. There may be an additional cost.
Motif No. Description Motif No. Description Motif No. Description
Any escape sign luminaire for central emergency power supply can also be ordered as luminaire sign. Plese see the section on luminiare signs of our current product selection guide.
280 Specifications subject to alteration
LAMPS
Design- ZVEi- iLCOS- Nominal Nominal Max. luminous Beam Base nation/ abbre- abbre- wattage luminous flux intensitiy angle Symbol viation viation [W] Φ [lm] l [cd] [°]
Design- ZVEi- iLCOS- Nominal Nominal Max. luminous Beam Base nation/ abbre- abbre- wattage luminous flux intensitiy angle Symbol viation viation [W] Φ [lm] l [cd] [°]
Incandescent lamp
A60 iAA 15 90 E27
25 220 E27
40 415 E27
60 710 E27
75 935 E27
A
The specifications for the lamps used in the rZB catalogue are listed as neutrally as possible below. The lamp abbreviations are indicated in iLCOS and ZVEi LBS.The photometric values and bases for the lamps must be compared with the actual manufacturer’s specifications prior to incorporation in any light calculations or plan-ning. The table lists the maximum values (luminous flux Φ and luminous intensity i) for many of the lamps. in the case of lamps for which just one manufacturer is known at present, the manufacturer is indicated as a footnote.Manufacturer codes: 1) Philips 2) Sylvania 3) Osram 4) GE 5) rZB 6) Venture Lighting 7) Narva 8) Megaman
Compact fluorescent lamp, single tube
TC FSD 5 250 G23
7 400 G23
9 600 G23
11 900 G23
TC-EL FSD 5 250 2G7
7 400 2G7
9 600 2G7
11 900 2G7
TC
Compact fluorescent lamp, quadruple tube
TC-QEL FSMH 4)57 4300 GX24q-5
4)70 5200 GX24q-6
TC-QEL
Compact fluorescent lamp, triple tube
TC-T FSM 13 900 GX24 d-1
18 1200 GX24 d-2
26 1800 GX24 d-3
TC-TEL FSMH 13 900 GX24 q-1
18 1200 GX24 q-2
26 1800 GX24 q-3
32 2400 GX24 q-3
42 3200 GX24 q-4
57 4300 GX24 q-5
70 5200 GX24 q-6
TC-TEL FSMH 1)60 4000 2G8
1)85 6000 2G8
1)120 9000 2G8
TC-T
TC-TEL
Compact fluorescent lamp, double tube
TC-D FSQ 10 600 G24 d-1
13 900 G24 d-1
18 1200 G24 d-2
26 1800 G24 d-3
TC-DEL FSQH 10 600 G24 q-1
13 900 G24 q-1
18 1200 G24 q-2
26 1800 G24 q-3
TC-D
Fluorescent lamp
T7 FD-Ø7 6 330 W4.3
8 540 W4.3
11 750 W4.3
13 930 W4.3
T16 FD-Ø16 4 140 G5
6 270 G5
8 450 G5
13 1 000 G5
FDH-Ø16 14 1 200 G5
21 1 900 G5
24 1 750 G5
28 2 600 G5
35 3 300 G5
39 3 100 G5
49 4 300 G5
54 4 450 G5
80 6 150 G5
T26 FD-Ø26 10 650 G13
15 950 G13
16 1 250 G13
18 1 350 G13
30 2 400 G13
T26-1m FD-Ø26-1m 36 3 100 G13
FD-Ø26 36 3 350 G13
38 3 300 G13
58 5 200 G13
T16/T26
Compact fluorescent lamp, square curved
TC-DD FSS 16 1 050 Gr8 2p
16 1 050 Gr10q 4p
4)21 1 375 Gr10q 4p
28 2 050 Gr8 2p
28 2 050 Gr10q 4p
38 2 700 Gr10q 4p
4)55 3 900 Gr10q-3 4p
TC-DD
Compact fluorescent lamp, flat
TC-F FSS 18 1 100 2G10
24 1 700 2G10
36 2 800 2G10TC-F
Compact fluorescent lamp, Mikro-Lynx
TC-FSE FBC 2)6 220 GX53
8)7 220 GX53
8)9 360 GX53
8)13 520 GX53TC-FSE
Compact fluorescent lamp, long
TC-L FSD 18 1 200 2G11
24 1 800 2G11
36 2 900 2G11
40 3 500 2G11
55 4 800 2G11
80 6 000 2G11
28 2 800 2GX11
TC-L
T16-r
Fluorescent lamp, ring-shaped
T16-r FC-Ø16 22 1 800 2GX13
40 3 200 2GX13
55 4 200 2GX13
1)60 5 000 2GX13
T32-r
Fluorescent lamp, ring-shaped
T29-r FC-Ø29 22 1 250 G10q
T32-r FC-Ø52 32 2 100 G10q
40 2 800 G10q
281Specifications subject to alteration
CONDiTiONS OF SALE AND DELiVEry
General: Unless explicitly agreed otherwise in writing, the following terms and conditions of sale apply, based on the „General Terms and Conditions of Supply“ for products and services supplied by the electrical industry. Special terms and conditions relate, above all, to export sales, which are based on the respective export terms as commonly applied. Our terms and conditions of delivery apply even if purchasers exclude the validity of the supplier’s terms and conditions of sale in their terms and conditions of purchase and we do not explicitly refute these. Verbal and/or special agreements are only binding if confirmed in writing by ourselves.
Prices: The prices indicated in the price list are gross per unit ex factory, excluding value added tax, and are non-binding. The applicable prices on the day the order is received are used as the basis for calculation unless the order in question has, exceptionally, been explicitly confirmed at fixed prices. Value added tax will be charged separately at the applicable rate.
Packaging: Packaging is charged at cost price. 2/3 of the calculated value of reusable packaging will be credited in the event of carriage paid returns. The same applies to container rent in the case of container shipment.
Delivery: Prices are gross ex factory, excluding packaging, which will be invoiced at cost price. Orders for immediate delivery with a value of more than Euro 500 will be shipped carriage paid to the recipient’s railway sta-tion in Germany, excluding packaging; orders valued at EUr 1,000 net or more will be shipped carriage paid to the recipient’s railway station in Germany including packaging. Deliveries are shipped on the basis of freight collect; freight costs will be deducted from the invoice. if the value of an order entitles the purchaser to carriage paid shipment or carriage paid shipment including packaging, we reserve the right to ship parts of the order at a later date ex factory and excluding packaging if production-related issues prevent us from delivering these items immediately.
Delivery times: Delivery times indicated in the order confirmations are largely adhered to; they are, however, not binding. We reserve the right to ship orders in parts. Any claims asserted on the grounds of delayed deliveries will not be admitted.
Transfer of risk: The risk is transferred to the purchaser as soon as the shipment leaves our factory. The recipient bears the risk of transportation. Goods damaged in transit will not be reimbursed if breakage insurance of 1% of the net invoice amount is refused.
retention of title: Shipped goods remain our property until all outstand-ing claims against the purchaser have been met in full. The purchaser may use the goods that are subject to retention of title in the course of normal business operations. The purchaser is not permitted to pledge or transfer the goods by way of security or to assign them by any other means; we must be notified immediately of any seizures by third parties or other impairments of goods that are subject to retention of title. The purchaser already consents to assign any claims arising from the resale of goods subject to retention of title to the vendor and authorises the vendor to col-lect said claims. in spite of the aforementioned agreement, the purchaser remains authorised to collect any claims until we revoke such authorisation in writing. Upon our request, the purchaser must notify the debtor of the assignment of the claim. The vendor is entitled to give notice of this assign-ment. The reten-tion of title also extends to the full value of any products created by processing, blending or combining our goods. in this respect, we are deemed to be the manufacturer, and the purchaser shall exempt us from any obligations arising therefrom. in the event that third parties retain a right of title to goods used in the processing, blending or combination with our goods, we acquire co-title to the newly created products in the ratio of the invoice values of the processed goods. We are authorised to access the purchaser’s warehouse or to commission an agent to access the purchaser’s warehouse for the purpose of inspecting the goods that are subject to retention of title. We undertake to release the retention of title at our discretion if the value of the same exceeds the claims to be secured by 20%.
Notification of defects: Complaints relating to shipped goods will only be considered if submitted within 8 days from receipt of the goods. The purchaser must provide proof to substantiate any complaint. in the event that we acknowledge the defect, we reserve the right to decide whether to accept the return of the defective merchandise in return for the revocation of the purchase contract or to replace it free of charge within a reasonable period or to credit the reduction in the value of the goods. Warranties for defects can only be accepted if such defects have demonstrably been caused by circumstances occurring prior to the transfer of risk. The war-ranty period is limited to a maximum of 12 months following the transfer of risk. We must be notified of any defects in writing as soon as they are detected. returns will only be accepted if agreed in advance.Claims for damages asserted by the purchaser are excluded, irrespective of the legal grounds on which they are asserted and in particular in respect of any violations of contractual obligations and impermissible actions. This does not apply to statutory liability obligations, e.g. pursuant to the Product Liability Act, in cases of premeditation or gross negligence, if life, limb or health are threatened or material contractual obligations violated. Compensation for violations of material contractual obligations is, however, limited to the contract-specific, foreseeable damage unless such dam-age is caused by premeditation or gross negligence or liability must be assumed for injury to life, limb or health. The aforementioned regulations do not constitute a reversal of the burden of proof to the disadvantage of the purchaser.
returns: Purchasers may only cancel an order in part or whole with our prior consent. in such cases, we reserve the right to charge 30% of the value of the goods as partial reimbursement of our costs. Goods that have already been delivered may only be returned – if at all – in a re-sellable con-dition and in their original packaging. Custom-made products, luminaire signs and safety luminaires, merchandise procured at the request of the customer, incandescent and fluorescent lamps and electronic switching equipment may not be returned. in the event that we consent to the return, we will issue a return slip which must be included with the return. Standard and undamaged goods in original packaging will be credited at a maximum of 70% of the invoiced price. All reconditioning, freight and packaging costs must, moreover, be borne by the purchaser. returns are always shipped at the risk of the customer returning the merchandise. No credit will be issued for goods returned without a written declaration of consent by rZB. Such goods may be disposed of at the sender’s expense.
Weights, dimensions, technical specifications and illustrations have been prepared with all due care (E&OE) but are not binding since the construction, design and technical specifications of our products are con-stantly changing to keep pace with technical progress.
Payment terms: invoices are payable net and without any deductions within 30 days from invoice date. We grant a 2% discount on the net value of the merchandise if invoices are paid in advance or within 8 days from invoice date. in the event of delayed payment, we reserve the right to charge default interest at a rate of 5% above the applicable base rate pursuant to Section 1 Discount rate Transition Act. A processing sur-charge of Euro 10 will be levied on orders with a value of Euro 50 or less. in the event of default, the entire amounts receivable by us become due for payment immediately.
Disposal: Non-private purchasers undertake to ensure the disposal of the purchased products in accordance with the provisions of the German Electrical and Electronic Equipment Act (ElektroG). in the event of resale, the purchaser transfers this obligation to their contractual partner. EU customers not resident in Germany: Please note the implementation of the WEEE Directive in national legislation.
Place of performance and general court of jurisdiction for deliver-ies and payments and for all other obligations is, without exception, Bamberg. The General Terms and Conditions of Supply for products and services supplied by the electrical industry apply. Please do not hesitate to contact us if you require a copy.
282
No. Page No. Page No. Page No. Page No. PageNo. Page
ArTiCLE NUMBEr iNDEX
671207.004.72 177671207.004.81 177671207.004.82 177671207.752 177671207.752.71 177671207.752.72 177671207.752.81 177671207.752.82 177671207.754 177671207.754.71 177671207.754.72 177671207.754.81 177671207.754.82 177671208.002 177671208.002.71 177671208.002.72 177671208.002.81 177671208.002.82 177671208.004 177671208.004.71 177671208.004.72 177671208.004.81 177671208.004.82 177671209.752 177671209.752.71 177671209.752.72 177671209.752.81 177671209.752.82 177671209.754 177671209.754.71 177671209.754.72 177671209.754.81 177671209.754.82 177671211.002 177671211.002.71 177671211.002.72 177671211.002.81 177671211.002.82 177671211.004 177671211.004.71 177671211.004.72 177671211.004.81 177671211.004.82 177671211.752 177671211.752.71 177671211.752.72 177671211.752.81 177671211.752.82 177671211.754 177671211.754.71 177671211.754.72 177671211.754.81 177671211.754.82 177671213.002 177671213.002.71 177671213.002.72 177671213.002.81 177671213.002.82 177671213.004 177671213.004.71 177671213.004.72 177671213.004.81 177671213.004.82 177
09-6019.000 11709-6202.009 15109-6230.000 15109-6284.000 11509-6285.000 11509-6286.000 11509-6287.000 11509-6288.000 11509-6289.000 11509-6290.000 11509-6291.000 11509-6292.000 11509-6293.000 11509-6294.000 11509-6295.000 115
22125.002 63, 19722125.003 63, 197
65133 5565936 11165938 11165940 11165942 111
67000.0.152 14367004.009 6767005.009 6767006.009 67
671001.752 37671001.752.03 37671001.752.04 37671001.754 37671001.754.03 37671001.754.04 37671003.752 37671003.752.03 37671003.752.04 37671003.754 37671003.754.03 37671003.754.04 37671005.752 37671005.752.03 37671005.752.04 37671005.754 37671005.754.03 37671005.754.04 37671009.752 43671009.752.03 43671009.752.04 43671011.752 43671011.752.03 43671011.752.04 43671013.752 43671013.752.03 43671013.752.04 43671017.752 42671017.752.03 42671017.752.04 42671023.752 42671023.752.03 42671023.752.04 42671045.002 45
671045.002.03 45671045.002.04 45671045.004 45671045.004.03 45671045.004.04 45671045.752 45671045.752.03 45671045.752.04 45671045.754 45671045.754.03 45671045.754.04 45671049.002 45671049.002.03 45671049.002.04 45671049.004 45671049.004.03 45671049.004.04 45671049.752 45671049.752.03 45671049.752.04 45671049.754 45671049.754.03 45671049.754.04 45671053.002 45671053.002.03 45671053.002.04 45671053.004 45671053.004.03 45671053.004.04 45671053.752 45671053.752.03 45671053.752.04 45671053.754 45671053.754.03 45671053.754.04 45671057.002 45671057.002.03 45671057.002.04 45671057.004 45671057.004.03 45671057.004.04 45671057.752 45671057.752.03 45671057.752.04 45671057.754 45671057.754.03 45671057.754.04 45671061.002 46671061.002.03 46671061.002.04 46671061.004 46671061.004.03 46671061.004.04 46671061.752 46671061.752.03 46671061.752.04 46671061.754 46671061.754.03 46671061.754.04 46671065.002 46671065.002.03 46671065.002.04 46671065.004 46
671065.004.03 46671065.004.04 46671065.752 46671065.752.03 46671065.752.04 46671065.754 46671065.754.03 46671065.754.04 46671069.002 46671069.002.03 46671069.002.04 46671069.004 46671069.004.03 46671069.004.04 46671069.752 46671069.752.03 46671069.752.04 46671069.754 46671069.754.03 46671069.754.04 46671073.002 46671073.002.03 46671073.002.04 46671073.004 46671073.004.03 46671073.004.04 46671073.752 46671073.752.03 46671073.752.04 46671073.754 46671073.754.03 46671073.754.04 46671077.002 47671077.002.03 47671077.002.04 47671077.004 47671077.004.03 47671077.004.04 47671077.752 47671077.752.03 47671077.752.04 47671077.754 47671077.754.03 47671077.754.04 47671081.002 47671081.002.03 47671081.002.04 47671081.004 47671081.004.03 47671081.004.04 47671081.752 47671081.752.03 47671081.752.04 47671081.754 47671081.754.03 47671081.754.04 47671085.002 47671085.002.03 47671085.002.04 47671085.004 47671085.004.03 47671085.004.04 47671085.752 47
671085.752.03 47671085.752.04 47671085.754 47671085.754.03 47671085.754.04 47671089.002 47671089.002.03 47671089.002.04 47671089.004 47671089.004.03 47671089.004.04 47671089.752 47671089.752.03 47671089.752.04 47671089.754 47671089.754.03 47671089.754.04 47671093.752 109671093.752.03 109671093.752.04 109671095.912 99671095.912.03 99671095.912.04 99
671107.912 107671107.912.03 107671107.912.04 107671107.913 107671107.913.03 107671107.913.04 107671109.912 107671109.912.03 107671109.912.04 107671109.913 107671109.913.03 107671109.913.04 107671111.752 63671111.752.03 63671111.752.04 63671111.753 63671111.753.03 63671111.753.04 63671112.922 99671112.922.03 99671112.922.04 99671113.752 63671113.752.03 63671113.752.04 63671113.753 63671113.753.03 63671113.753.04 63671116.750 67671148.000 16671178.752 169671178.752.71 169671178.752.72 169671178.752.81 169671178.752.82 169671178.754 169671178.754.71 169671178.754.72 169671178.754.81 169671178.754.82 169
671179.752 169671179.752.71 169671179.752.72 169671179.752.81 169671179.752.82 169671179.754 169671179.754.71 169671179.754.72 169671179.754.81 169671179.754.82 169671180.752 169671180.752.71 169671180.752.72 169671180.752.81 169671180.752.82 169671180.754 169671180.754.71 169671180.754.72 169671180.754.81 169671180.754.82 169671181.752 175671181.752.71 175671181.752.72 175671181.752.81 175671181.752.82 175671182.752 175671182.752.71 175671182.752.72 175671182.752.81 175671182.752.82 175671183.752 175671183.752.71 175671183.752.72 175671183.752.81 175671183.752.82 175671184.752 175671184.752.71 175671184.752.72 175671184.752.81 175671184.752.82 175671185.752 174671185.752.71 174671185.752.72 174671185.752.81 174671185.752.82 174671186.752 174671186.752.71 174671186.752.72 174671186.752.81 174671186.752.82 174671188.752 174671188.752.71 174671188.752.72 174671188.752.81 174671188.752.82 174
671207.002 177671207.002.71 177671207.002.72 177671207.002.81 177671207.002.82 177671207.004 177671207.004.71 177
283
No. PageNo. Page No. Page No. Page No. PageNo. Page
ArTiCLE NUMBEr iNDEX
671351.752.04 47671351.754 47671351.754.03 47671351.754.04 47671357.002 177671357.004 177671359.002 177671359.002.71 177671359.002.72 177671359.002.81 177671359.002.82 177671359.004 177671359.004.71 177671359.004.72 177671359.004.81 177671359.004.82 177671359.752 177671359.752.71 177671359.752.72 177671359.752.81 177671359.752.82 177671359.754 177671359.754.71 177671359.754.72 177671359.754.81 177671359.754.82 177671361.002 178671361.004 178671363.002 178671363.002.71 178671363.002.72 178671363.002.81 178671363.002.82 178671363.004 178671363.004.71 178671363.004.72 178671363.004.81 178671363.004.82 178671363.752 178671363.752.71 178671363.752.72 178671363.752.81 178671363.752.82 178671363.754 178671363.754.71 178671363.754.72 178671363.754.81 178671363.754.82 178671365.002 179671365.004 179671367.002 179671367.002.71 179671367.002.72 179671367.002.81 179671367.002.82 179671367.004 179671367.004.71 179671367.004.72 179671367.004.81 179671367.004.82 179671367.752 179671367.752.71 179671367.752.72 179
671223.752.71 178671223.752.72 178671223.752.81 178671223.752.82 178671223.754 178671223.754.71 178671223.754.72 178671223.754.81 178671223.754.82 178671227.002 178671227.002.71 178671227.002.72 178671227.002.81 178671227.002.82 178671227.004 178671227.004.71 178671227.004.72 178671227.004.81 178671227.004.82 178671227.752 178671227.752.71 178671227.752.72 178671227.752.81 178671227.752.82 178671227.754 178671227.754.71 178671227.754.72 178671227.754.81 178671227.754.82 178671229.002 179671229.002.71 179671229.002.72 179671229.002.81 179671229.002.82 179671229.004 179671229.004.71 179671229.004.72 179671229.004.81 179671229.004.82 179671229.752 179671229.752.71 179671229.752.72 179671229.752.81 179671229.752.82 179671229.754 179671229.754.71 179671229.754.72 179671229.754.81 179671229.754.82 179671231.002 179671231.002.71 179671231.002.72 179671231.002.81 179671231.002.82 179671231.004 179671231.004.71 179671231.004.72 179671231.004.81 179671231.004.82 179671231.752 179671231.752.71 179671231.752.72 179671231.752.81 179
671231.752.82 179671231.754 179671231.754.71 179671231.754.72 179671231.754.81 179671231.754.82 179671233.002 179671233.002.71 179671233.002.72 179671233.002.81 179671233.002.82 179671233.004 179671233.004.71 179671233.004.72 179671233.004.81 179671233.004.82 179671233.752 179671233.752.71 179671233.752.72 179671233.752.81 179671233.752.82 179671233.754 179671233.754.71 179671233.754.72 179671233.754.81 179671233.754.82 179671235.002 179671235.002.71 179671235.002.72 179671235.002.81 179671235.002.82 179671235.004 179671235.004.71 179671235.004.72 179671235.004.81 179671235.004.82 179671235.752 179671235.752.71 179671235.752.72 179671235.752.81 179671235.752.82 179671235.754 179671235.754.71 179671235.754.72 179671235.754.81 179671235.754.82 179671236.912 185671236.912.71 185671236.912.81 185671236.912.82 185671237.912 185671237.912.71 185671237.912.81 185671237.912.82 185671238.912 185671238.912.71 185671238.912.81 185671238.912.82 185671247.912 197671247.912.71 197671247.912.72 197671247.912.81 197671247.912.82 197
671213.752 177671213.752.71 177671213.752.72 177671213.752.81 177671213.752.82 177671213.754 177671213.754.71 177671213.754.72 177671213.754.81 177671213.754.82 177671215.002 178671215.002.71 178671215.002.72 178671215.002.81 178671215.002.82 178671215.004 178671215.004.71 178671215.004.72 178671215.004.81 178671215.004.82 178671215.752 178671215.752.71 178671215.752.72 178671215.752.81 178671215.752.82 178671215.754 178671215.754.71 178671215.754.72 178671215.754.81 178671215.754.82 178671217.002 178671217.002.71 178671217.002.72 178671217.002.81 178671217.002.82 178671217.004 178671217.004.71 178671217.004.72 178671217.004.81 178671217.004.82 178671217.752 178671217.752.71 178671217.752.72 178671217.752.81 178671217.752.82 178671217.754 178671217.754.71 178671217.754.72 178671217.754.81 178671219.752 42671219.752.03 42671219.752.04 42671223.002 178671223.002.71 178671223.002.72 178671223.002.81 178671223.002.82 178671223.004 178671223.004.71 178671223.004.72 178671223.004.81 178671223.004.82 178671223.752 178
671247.913 197671247.913.71 197671247.913.72 197671247.913.81 197671247.913.82 197671248.912 197671248.912.71 197671248.912.72 197671248.912.81 197671248.912.82 197671248.913 197671248.913.71 197671248.913.72 197671248.913.81 197671248.913.82 197671253.002 189671253.003 189671254.912 189671254.913 189671256.002 177671256.004 177671258.002 177671258.004 177671260.002 177671260.004 177671262.002 177671262.004 177671264.002 178671264.004 178671266.002 178671266.004 178671268.002 178671268.004 178671270.002 178671270.004 178671272.002 179671272.004 179671274.002 179671274.004 179671276.002 179671276.004 179671278.002 179671278.004 179671283.002 185671284.002 185671285.002 185671286.002 185671287.912 185671287.912.71 185671287.912.81 185671287.912.82 185671288.002 185671289.912 185671289.912.71 185671289.912.81 185671289.912.82 185671290.752 197671290.752.71 197671290.752.72 197671290.752.81 197671290.752.82 197671290.753 197671290.753.71 197
671290.753.72 197671290.753.81 197671290.753.82 197671291.752 197671291.752.71 197671291.752.72 197671291.752.81 197671291.752.82 197671291.753 197671291.753.71 197671291.753.72 197671291.753.81 197671291.753.82 197
671308.002 185671309.912 185671309.912.71 185671309.912.81 185671309.912.82 185671311.752 42671311.752.03 42671311.752.04 42671312.752 174671312.752.71 174671312.752.72 174671312.752.81 174671312.752.82 174671315.000 16671321.752 56671321.752.03 56671321.752.04 56671343.002 45671343.002.03 45671343.002.04 45671343.004 45671343.004.03 45671343.004.04 45671343.752 45671343.752.03 45671343.752.04 45671343.754 45671343.754.03 45671343.754.04 45671347.002 46671347.002.03 46671347.002.04 46671347.004 46671347.004.03 46671347.004.04 46671347.752 46671347.752.03 46671347.752.04 46671347.754 46671347.754.03 46671347.754.04 46671351.002 47671351.002.03 47671351.002.04 47671351.004 47671351.004.03 47671351.004.04 47671351.752 47671351.752.03 47
284
No. Page No. Page No. Page No. Page No. PageNo. Page
ArTiCLE NUMBEr iNDEX
671717.752.04 42671718.752 97671718.752.03 97671718.752.04 97671719.752 97671719.752.03 97671719.752.04 97671722.004 165671722.004.71 165671722.004.72 165671722.004.81 165671722.004.82 165671735.922 105671735.922.03 105671735.922.04 105671735.9231 105671735.9231.03 105671735.9231.04 105671735.924 105671735.924.03 105671735.924.04 105671736.004 164671736.004.71 164671736.004.72 164671736.004.81 164671736.004.82 164671737.004 165671737.004.71 165671737.004.72 165671737.004.81 165671737.004.82 165671738.004 164671738.004.71 164671738.004.72 164671738.004.81 164671738.004.82 164671739.004 164671739.004.71 164671739.004.72 164671739.004.81 164671739.004.82 164671740.004 165671740.004.71 165671740.004.72 165671740.004.81 165671740.004.82 165671742.004 30671742.004.03 30671742.004.04 30671744.004 31671744.004.03 31671744.004.04 31671746.004 30671746.004.03 30671746.004.04 30671748.004 31671748.004.03 31671748.004.04 31671750.004 30671750.004.03 30671750.004.04 30671752.004 31671752.004.03 31
671560.002.04 39671574.752 56671574.752.03 56671574.752.04 56671585.862.1 89671585.862.1.03 89671585.862.1.04 89671586.752 43671586.752.03 43671586.752.04 43671587.962.1 89671587.962.1.03 89671587.962.1.04 89671588.752 42671588.752.03 42671588.752.04 42671590.752 41671590.752.03 41671590.752.04 41671592.752 41671592.752.03 41671592.752.04 41671594.752 41671594.752.03 41671594.752.04 41671596.752 41671596.752.03 41671596.752.04 41671597.752 173671597.752.71 173671597.752.72 173671597.752.81 173671597.752.82 173671598.752 173671598.752.71 173671598.752.72 173671598.752.81 173671598.752.82 173671599.752 173671599.752.71 173671599.752.72 173671599.752.81 173671599.752.82 173
671600.752 173671600.752.71 173671600.752.72 173671600.752.81 173671600.752.82 173671601.002 187671601.002.81 187671601.002.82 187671601.922 187671601.922.71 187671601.922.72 187671601.922.81 187671602.922 187671602.922.71 187671602.922.72 187671602.922.81 187671602.922.82 187671605.922 53671605.922.03 53
671367.752.81 179671367.752.82 179671367.754 179671367.754.71 179671367.754.72 179671367.754.81 179671367.754.82 179671368.752 51671368.752.03 51671368.752.04 51671370.752 51671370.752.03 51671370.752.04 51671372.002 183671373.752 183671373.752.71 183671373.752.72 183671373.752.81 183671373.752.82 183671374.912 183671374.912.71 183671374.912.72 183671374.912.81 183671374.912.82 183671375.002 183671376.752 183671376.752.71 183671376.752.72 183671376.752.81 183671376.752.82 183671377.912 183671377.912.71 183671377.912.72 183671377.912.81 183671377.912.82 183671378.002 183671379.752 183671379.752.71 183671379.752.72 183671379.752.81 183671379.752.82 183671380.912 183671380.912.71 183671380.912.72 183671380.912.81 183671380.912.82 183671381.002 183671382.752 183671382.752.71 183671382.752.72 183671382.752.81 183671382.752.82 183671383.912 183671383.912.71 183671383.912.72 183671383.912.81 183671383.912.82 183671384.002 190671386.912 190671386.912.71 190671386.912.72 190671386.912.81 190671386.912.82 190
671387.922 190671387.922.71 190671387.922.72 190671387.922.81 190671387.922.82 190
671422.912 99671422.912.03 99671422.912.04 99671423.912 93671423.912.03 93671423.912.04 93671425.912 101671425.912.03 101671425.912.04 101671427.912 103671427.912.03 103671427.912.04 103671446.752 109671446.752.03 109671446.752.04 109671447.752 43671447.752.03 43671447.752.04 43671455.962 95671455.962.03 95671455.962.04 95671456.952 95671456.952.03 95671456.952.04 95671466.009 23671467.752 51671467.752.03 51671467.752.04 51671493.982 95671493.982.03 95671493.982.04 95671494.862 95671494.862.03 95671494.862.04 95671495.962 91671495.962.03 91671495.962.04 91671496.952 91671496.952.03 91671496.952.04 91671497.982 91671497.982.03 91671497.982.04 91671498.862 91671498.862.03 91671498.862.04 91
671501.004 29671501.004.03 29671501.004.04 29671502.004 29671502.004.03 29671502.004.04 29671503.004 163671503.004.71 163671503.004.72 163671503.004.81 163671503.004.82 163
671504.004 163671504.004.71 163671504.004.72 163671504.004.81 163671504.004.82 163671515.752 58671515.752.03 58671515.752.04 58671517.752 58671517.752.03 58671517.752.04 58671518.004 29671518.004.03 29671518.004.04 29671519.004 163671519.004.71 163671519.004.72 163671519.004.81 163671519.004.82 163671520.002 56671521.002 95671521.002.03 95671521.002.04 95671531.952.1 89671531.952.1.03 89671531.952.1.04 89671546.002 29671546.002.03 29671546.002.04 29671546.004 29671546.004.03 29671546.004.04 29671546.122 29671546.122.03 29671546.122.04 29671546.124 29671546.124.03 29671546.124.04 29671547.002 163671547.004 163671547.122 163671547.124 163671555.002 171671555.002.71 171671555.002.81 171671555.002.82 171671556.002 171671556.002.71 171671556.002.72 171671556.002.81 171671556.002.82 171671557.002 171671557.002.71 171671557.002.81 171671557.002.82 171671558.002 39671558.002.03 39671558.002.04 39671559.002 39671559.002.03 39671559.002.04 39671560.002 39671560.002.03 39
671605.922.04 53671606.922 53671606.922.03 53671606.922.04 53671607.002 171671607.002.71 171671607.002.72 171671607.002.81 171671607.002.82 171671608.752 61671609.752 61671609.752.03 61671609.752.04 61671611.000 16671612.922 187671612.922 187671612.922.71 187671612.922.71 187671612.922.72 187671612.922.72 187671612.922.81 187671612.922.81 187671612.922.82 187671612.922.82 187671614.922 53671614.922.03 53671614.922.04 53671615.002 39671615.002.03 39671615.002.04 39671616.759 235671616.759.71 235671616.759.72 235671616.759.81 235671616.759.82 235671617.759 235671617.759.71 235671617.759.72 235671617.759.81 235671617.759.82 235671618.752 56671619.752 58671620.752 58671629.752 192671629.752.71 192671629.752.72 192671629.752.81 192671629.752.82 192671630.752 192671630.752.71 192671630.752.72 192671630.752.81 192671630.752.82 192671639.752 56
671700.342.1 89671700.342.1.03 89671700.342.1.04 89671707.002 57671707.002.03 57671707.002.04 57671717.752 42671717.752.03 42
285
No. PageNo. Page No. Page No. Page No. PageNo. Page
ArTiCLE NUMBEr iNDEX
671907.002.03 59671907.002.04 59671908.002 57671908.002.04 57671909.002 57671909.002.04 57671911.952.1 89671911.952.1.03 89671911.952.1.04 89671912.004.03 31671912.004.04 31671913.004 31671913.004.03 31671913.004.04 31671914.004 31671914.004.03 31671914.004.04 31671915.004 33671916.002 203671917.002 73671917.002.07 73671918.002 73671918.002.07 73671919.002 199671919.002.71 199671919.002.72 199671919.002.81 199671919.002.82 199671920.002 69671920.002.07 69671921.002 69671921.002.07 69671922.004 161671922.004.71 161671922.004.72 161671922.004.81 161671922.004.82 161671923.004 161671923.004.71 161671923.004.72 161671923.004.81 161671923.004.82 161671927.002 71671927.002.07 71671928.002 71671928.002.07 71671929.002 71671929.002.07 71671930.002 71671930.002.07 71671931.002 71671931.002.07 71671932.002 71671932.002.07 71671933.002 71671933.002.07 71671934.002 71671934.002.07 71671936.002 201671938.004 161671938.004.71 161671938.004.72 161671938.004.81 161
671792.002 59671792.002.03 59671792.002.04 59671793.002 193671793.002.71 193671793.002.72 193671793.002.81 193671793.002.82 193671799.802 219671799.802.71 219671799.802.72 219671799.802.81 219671799.802.82 219
671800.802 219671800.802.71 219671800.802.72 219671800.802.81 219671800.802.82 219671801.002 219671801.002.71 219671801.002.72 219671801.002.81 219671801.002.82 219671802.862 87671802.862.03 87671802.862.04 87671803.862 87671803.862.03 87671803.862.04 87671817.009 55671819.002 59671819.002.03 59671819.002.04 59671820.002 193671820.002.71 193671820.002.72 193671820.002.81 193671820.002.82 193671822.002 187671822.002.71 187671822.002.71 187671822.002.72 187671822.002.81 187671822.002.81 187671822.002.82 187671823.000 19671824.009 111671826.002 187671826.002.71 187671826.002.72 187671826.002.81 187671826.002.82 187671835.002 207671835.002.81 207671835.002.82 207671836.002 75671837.002 205671837.002.82 205671838.002 75671839.002 205671839.002.82 205671840.002 75
671841.002 205671841.002.82 205671842.0031 35671843.0031 167671843.0031.82 167671846.0031 35671847.0031 167671847.0031.82 167671854.002 207671854.002.81 207671854.002.82 207671857.962 85671857.962.03 85671857.962.04 85671858.952 85671858.952.03 85671858.952.04 85671859.962 85671859.962.03 85671859.962.04 85671860.952 85671860.952.03 85671860.952.04 85671869.962 217671869.962.71 217671869.962.72 217671869.962.81 217671869.962.82 217671870.952 217671870.952.71 217671870.952.72 217671870.952.81 217671870.952.82 217671871.962 217671871.962.71 217671871.962.72 217671871.962.81 217671871.962.82 217671872.952 217671872.952.71 217671872.952.72 217671872.952.81 217671872.952.82 217671873.924 77671873.924.03 77671873.924.04 77671874.964 77671874.964.03 77671874.964.04 77671875.924 77671875.924.03 77671875.924.04 77671876.964 77671876.964.03 77671876.964.04 77671877.924 209671877.924.71 209671877.924.72 209671877.924.81 209671877.924.82 209671878.964 209671878.964.71 209671878.964.72 209
671752.004.04 31671774.752 195671774.752.71 195671774.752.72 195671774.752.81 195671774.752.82 195671775.002 191671775.002.71 191671775.002.72 191671775.002.81 191671775.002.82 191671776.752 195671776.752.71 195671776.752.72 195671776.752.81 195671776.752.82 195671777.862 87671777.862.03 87671777.862.04 87671778.862 87671778.862.03 87671778.862.04 87671779.862 87671779.862.03 87671779.862.04 87671780.002 57671780.002.03 57671780.002.04 57671781.002 219671781.002.71 219671781.002.72 219671781.002.81 219671781.002.82 219671781.004 219671781.004.71 219671781.004.72 219671781.004.81 219671781.004.82 219671782.002 191671782.002.71 191671782.002.72 191671782.002.81 191671782.002.82 191671790.802 219671790.802.71 219671790.802.72 219671790.802.81 219671790.802.82 219671790.804 219671790.804.71 219671790.804.72 219671790.804.81 219671790.804.82 219671791.802 219671791.802.71 219671791.802.72 219671791.802.81 219671791.802.82 219671791.804 219671791.804.71 219671791.804.72 219671791.804.81 219671791.804.82 219
671878.964.81 209671878.964.82 209671879.924 209671879.924.71 209671879.924.72 209671879.924.81 209671879.924.82 209671880.964 209671880.964.71 209671880.964.72 209671880.964.81 209671880.964.82 209671881.834 79671881.834.03 79671881.834.04 79671882.834 79671882.834.03 79671882.834.04 79671883.834 211671883.834.71 211671883.834.72 211671883.834.81 211671883.834.82 211671884.834 211671884.834.71 211671884.834.72 211671884.834.81 211671884.834.82 211671885.822 213671885.822.71 213671885.822.72 213671885.822.81 213671885.822.82 213671885.824 213671885.824.71 213671885.824.72 213671885.824.81 213671885.824.82 213671886.842 213671886.842.71 213671886.842.72 213671886.842.81 213671886.842.82 213671886.844 213671886.844.71 213671886.844.72 213671886.844.81 213671886.844.82 213671887.832 213671887.832.71 213671887.832.72 213671887.832.81 213671887.832.82 213671887.834 213671887.834.71 213671887.834.72 213671887.834.81 213671887.834.82 213671888.822 215671888.822.71 215671888.822.72 215671888.822.81 215671888.822.82 215
671888.824 215671888.824.71 215671888.824.72 215671888.824.81 215671888.824.82 215671889.842 215671889.842.71 215671889.842.72 215671889.842.81 215671889.842.82 215671889.844 215671889.844.71 215671889.844.72 215671889.844.81 215671889.844.82 215671890.832 215671890.832.71 215671890.832.72 215671890.832.81 215671890.832.82 215671890.834 215671890.834.71 215671890.834.72 215671890.834.81 215671890.834.82 215671891.842 81671891.842.03 81671891.842.04 81671891.844 81671891.844.03 81671891.844.04 81671892.842 81671892.842.03 81671892.842.04 81671892.844 81671892.844.03 81671892.844.04 81671893.842 83671893.842.03 83671893.842.04 83671893.844 83671893.844.03 83671893.844.04 83671894.842 83671894.842.03 83671894.842.04 83671894.844 83671894.844.03 83671894.844.04 83671895.004 30671895.004.03 30671895.004.04 30671896.004 30671896.004.03 30671896.004.04 30671897.004 30671897.004.03 30671897.004.04 30
671906.002 59671906.002.03 59671906.002.04 59671907.002 59
286
No. Page No. Page No. Page No. Page No. PageNo. Page
ArTiCLE NUMBEr iNDEX
985021 156985054 157985055 157985107 124985138 149985147 149985182 157985195 156985212 143985213 143985214 143985215 143985216 143985217 143985218 143985238 124985256 149985272 152985273 153985274 153985279 154985280 154985288 134985289 134985290 134985291 135985292 135985293 135985364 149985366 139985367 139985368 139985369 139985370 139985371 139985372 139985373 139985374 139985375 139985377 139985405 11985406 11
991112 61991116 53991117 53991118 53
99350 27299350.1 27299351 272
981144.002 56981158.003 116981158.003.03 116981158.003.04 116981159.003 116981159.003.03 116981159.003.04 116981160.003 116981160.003.03 116981160.003.04 116981161.003 116981161.003.03 116981161.003.04 116981162.002 116981162.002.03 116981162.002.04 116981163.002 116981163.002.03 116981163.002.04 116981164.002 116981164.002.03 116981164.002.04 116981165.002 116981165.002.03 116981165.002.04 116981167.002 41981168.002 37
981348.002 155981352.003 150981353.009 150
981485.002 58981489.002 37
981502.000 118981504.000 118981506.000 118981508.000 118981510.000 118981512.000 118981581.004 29981583.002 58981586.002 169
981639.010 29981639.020 163981639.030 29981639.040 29981639.060 163981640.000 31981647.000 165981647.010 31981647.020 165981647.030 31981647.040 31981653.002 77981653.004 77981653.102 77981653.104 77981656.000 77981659.002 79981659.004 79981660.002 79981660.004 79
671938.004.82 161671939.004 161671939.004.71 161671939.004.72 161671939.004.81 161671939.004.82 161671940.004 161671940.004.71 161671940.004.72 161671940.004.81 161671940.004.82 161671941.004 161671941.004.71 161671941.004.72 161671941.004.81 161671941.004.82 161671942.004 161671942.004.71 161671942.004.72 161671942.004.81 161671942.004.82 161671943.004 27671943.004.04 27671943.004.07 27671944.004 27671944.004.04 27671944.004.07 27671945.004 27671945.004.04 27671945.004.07 27671946.004 27671946.004.04 27671946.004.07 27671947.004 27671947.004.04 27671947.004.07 27671948.004 27671948.004.04 27671948.004.07 27671949.004 27671949.004.04 27671949.004.07 27671950.002 201671950.002.71 201671950.002.72 201671950.002.81 201671950.002.82 201671951.002 201671951.002.71 201671951.002.72 201671951.002.81 201671951.002.82 201671952.002.1 221671952.002.1.71 221671952.002.1.72 221671952.002.1.81 221671952.002.1.82 221671952.002.2 221671952.002.2.71 221671952.002.2.72 221671952.002.2.81 221671952.002.2.82 221671953.922 225
671953.922.71 225671953.922.72 225671953.922.81 225671953.922.82 225671954.842 225671954.842.71 225671954.842.72 225671954.842.81 225671954.842.82 225671955.952 225671955.952.71 225671955.952.72 225671955.952.81 225671955.952.82 225671956.952 225671956.952.71 225671956.952.72 225671956.952.81 225671956.952.82 225671957.002 225671957.002.71 225671957.002.72 225671957.002.81 225671957.002.82 225671958.962.1 223671958.962.1.71 223671958.962.1.72 223671958.962.1.81 223671958.962.1.82 223671958.962.2 223671958.962.2.71 223671958.962.2.72 223671958.962.2.81 223671958.962.2.82 223671959.952.1 223671959.952.1.71 223671959.952.1.72 223671959.952.1.81 223671959.952.1.82 223671959.952.2 223671959.952.2.71 223671959.952.2.72 223671959.952.2.81 223671959.952.2.82 223671963.962 231671963.963 231671964.962 229671964.9631 229671964.964 229671965.952 229671965.9531 229671965.954 229671966.962 229671966.9631 229671966.964 229671967.952 229671967.9531 229671967.954 229671968.962 229671968.9631 229671968.964 229671969.952 229671969.9531 229
671969.954 229671970.962 229671970.9631 229671970.964 229671971.952 229671971.9531 229671971.954 229671972.922 231671972.923 231671973.962 231671973.963 231671974.813 233671974.813.71 233671974.813.72 233671974.813.81 233671974.813.82 233671975.912 237671975.913 237671975.919 237671976.912 237671976.913 237671976.919 237671977.0031 239671977.004 239
67923.750 6567924.750 65
90-3757.002 3790-3757.004 3790-4013.002 6390-4013.003 6390-4164.002 56
98102.002/176 7798102.002/215 79981095.000 229981098.002 225981098.004 225981098.0042 225981098.005 225981098.0061 225981098.0076 225981098.0082 225981098.009 225
981100.002 225981100.004 225981100.0042 225981100.005 225981100.0061 225981100.0076 225981100.0082 225981100.009 225981127.003 117981128.002 117981129.002 225981129.004 225981129.0042 225981129.005 225981129.0061 225981129.0076 225981129.0082 225981129.009 225
981662.000 79981678.002 213981678.004 213981685.000 29981686.000 30981687.000 31
981701.004 29981702.004 31981771.000 58981781.000 56981722.002 180981722.002.71 180981722.002.72 180981722.002.81 180981722.002.82 180981723.002 180981723.002.71 180981723.002.72 180981723.002.81 180981723.002.82 180981724.002 48981724.002.03 48981724.002.04 48981725.002 180981725.002.71 180981725.002.72 180981725.002.81 180981725.002.82 180981726.002 48981726.002.03 48981726.002.04 48981727.002 180981727.002.71 180981727.002.72 180981727.002.81 180981727.002.82 180981728.002 48981728.002.03 48981728.002.04 48981734.000 85981759.002 180981759.002.71 180981759.002.72 180981759.002.81 180981759.002.82 180981760.002 180981760.002.71 180981760.002.72 180981760.002.81 180981760.002.82 180981773.002 48981773.002.03 48981773.002.04 48981774.002 48981774.002.03 48981774.002.04 48981775.0031 35,167981776.000 35,167981777.0031 35981777.0131 167981777.0231 167
985019 156
287
No. PageNo. Page No. Page No. Page No. PageNo. Page
ALPHABETiCAL iNDEX
A
Abbreviations 272
Absence of feedback 263
Accessories (overview) 148
all CPS and LPS
systems 149-151
GV 1500 155-157
rZBeasy 155
LUXiFAir 152-154
LUXiFAirlight 152-154
Active star network 269
After sales service 289
Alphabetical index 287
Alu-Lux oval 230
Alu-rund
SC 106
CE 230
Andho (SC)
TC 80
TC iP 65 82
Andho (CE)
TC Flat 212
TC Flat iP 65 214
Anti-panic lighting 244
Arelo®
recessed downlight (SC) 84
recessed downlight (CE) 216
Article number codes
(explanation) 276
Article number index 282
B
Ballasts 273
Basic 98
Batteries 124
Batteries for group battery
system (GV 1500) 143
Battery cabinets 124
Building permit 264
Building code 264
C
Calculating the aeration
and ventilation of electrical
operation rooms 125
Centryxx
SC 74
CE 204
Central battery systems (CPS) Comparison 127
rZBbasic 128 LUXiFAir 132 LUXiFAirlight 138
Charging and charge maintenance device 124
Circuit identification signs 272
Connecting diagrams 119-121
Connecting diagrams 263
Connecting diagram for rZBeasy 202 / 204 147
Contact 289
Costs for weekly tests 261
D
DALi interface 10-13
Definition Viewing distance 242 Emergency lighting 242 Legend (pictogram) 242
Design SC 40-43 CE 172-175
Design of escape signs 262
Display SC 36 CE 168
DUO Control 154
Die-cast aluminium (Alu-Druckguss) 236
E
E 30 junction box 269
ECM module 152 (electric circuit module) 152
Edo SC 70 CE 200
Electric circuits 263
Electronic switches UE220e 150 UE220i 150 Dimming mode 151 Voltage control 151
Electrotechnical safety 273
Electrotechnical variants and additions 273
Emergency conversion kits 116
Emergency power supply unit PGVG 200 118
Energo TC 175 recessed downlight (SC) 76 recessed downlight (CE) 208
Energo TC 210
recessed downlight (SC) 78
recessed downlight (CE) 210
Escape and rescue
routes plan 265
European and international
regulations 242-246
EN 1838 242-243
EN 50171 245
EN 50172 244
EN 50272-2 245
EN 60598-2-22 246
EB 274
EVG 274
Explanation of catalogue
numbers 276
F
Flat Basic
SC 92
CE 224
Flat Basic with collar 94
Flat Polymero®
SC 88
CE 220
Flat Polymero® PC
with collar 90
Flat Polymero® PMMA 222
Flat Polymero® PC 222
Flat Polymero® rechteck
SC 96
CE 226
Flat Sign Mini/Midi
SC 38
CE 170
G
General 244
General information 273
German regulations 246-269
ASr (workplace
regulation) 265-266
BGV A8 (safe working
practices regulations) 262
DiN VDE 0100, Part 560 263
DiN VDE 0100, Part 718 263
DiN VDE 0108, Part 100 246
DiN 4844, Part 1 / Part 2 262
(M) LAr - (Model) wiring
systems directive 264
Group battery systems (LPS)
Comparison 141
rZB GV 1500 142
rZBeasy 202 / 204 144
GSUN® 2 55
GSUN® 2 LED 55
GSUN® 3 56
GSUN® 3 LED 57
GSUN® 4 58
GSUN® 4 LED 59
GSUN® S 32
H
Halyxx®
SC 28-31
CE 162-165
Hand-held LED
safety spotlight 110
Housing, fire-protected (E-30) 131
Housing with charging and
charge maintenance device 130
I
ilustris
SC 34
CE 166
information 273
information and warning
signs 245
inspections and controls
(of batteries) 245
installation example for
LUXiFAir 133
LUXiFAirlight 139
rZBbasic 129
rZBeasy 202 / 204 145
EC module 137, 152
installation example for
rZBeasy 202 / 204 146
iO Module, Light switch
setting sensor modules 153
iOM 230 for direct power
supply voltage 153
iOM 24 for potential-free
contacts 153
K
Kreis 100
L
Lamps 280
LCS-Z 194
LCS1 61
LCS3 61
SC = Self-contained safety luminaires | CE = Luminaires for central emergency power supply
288
iNDEX
LED 275
LED Halyxx®
SC 28-31
CE 162-165
Legends (pictograms)
Luminaire signs 278
Emergency escape
luminaires 277
Legends for emergency
luminaires 277
Legends for emergency escape
lighting 277
Light Case 232
Light switch setting sensor
module (LSM) 157
Linear network 269
Luminance (of safety signs) 262
Light Case 232
Lucio
SC 72
CE 202
Luminaires for
sports facilities 184
Luminaire signs
Legends (pictograms) 278
LUXiFAir 132
LUXiFAir Master 136
LUXiFAir sub distribution
board 134
LUXiFAirlight 138
LUXiFAirlight Master 140
Log book 244
M
Message and switchboard
(surface mounting) 149
Microprocessor control
and monitoring unit 130, 140
Mondana
SC 86
CE 218
Monitoring module
CONTrOL1 155
Monitoring via
DALi interface 11-13
Motifs and letterings for
luminaire signs 278-279
emergengy luminaires 277
MultiDigit® 14-16
Multivariabel
SC 50
CE 182
MWEB
monitoring module 16-18
MWEBplus 18
N
NCH complete
conversion kit 117
NCH module 117
NCH safety conversion kit 117
P
PGVG 200 118
Planning issues 268
Printer 149
Protection types 272
Protection classes 272
Power supply units 116
Power sources 263
PZ 50 22-23
r
rechteck (Universal 2) 188
rechteck 250 / 360 / 485
SC-overview 44
rechteck 250 45
rechteck 360 46
rechteck 485 47
rechteck 250 / 360 / 485
CE-overview 176
rechteck 250 177
rechteck 360 178
rechteck 485 179
remote control tableau,
type: MTB-BUS 156
rondo 102
rounded Maxi 104
rounded® extra flat 228
rZBbasic 128
rZBbasic sub distribution
board 131
rZBbasic components 130
rZBeasy 202 / 204 144
S
Safety and health signs 262
Safety-Spotlights 110
Safety marks 273
Servicing and testing 244
Signal amplifier 16
Signcube
SC 52
CE 186
SiNGLE Control 154
Symbol explanations 273
Signcube
SC 52
CE 186
SiNGLE Control 154
Solyxx 206
Space 64
Starter set 16
Special requirements for
battery rooms 245
T
Technical support 289
Tenuo
SC 26
CE 160
Test logs 263
Turia 68
Turia Z 198
TWiN control for group battery
system (GV 1500) 143
TWiN technology 155
U
Universal 2 188, 189
Universal 3 188, 190
Universal 3 LED 188, 191
Universal 4 188, 192
Universal 4 LED 188, 193
Universal changeover unit,
type: UUE 4/220 156
Universum 66
V
Varioplast i
SC 62
CE 196
Ventilation
(concerning batteries) 245
Visibility 244
W
Weatherproof battens
SC 108
CE 234
3
3-phase network monitoring
module 149
SC = Self-contained safety luminaires | CE = Luminaires for central emergency power supply
www.rzb-lighting.com
RZB Rudolf Zimmermann, Bamberg GmbH
Rheinstrasse 16, D-96052 Bamberg, Germany P.O. Box 29 40, D-96020 Bamberg, Germany
Telephone +49 951/79 09-374 Fax +49 951/79 09-212
www.rzb-lighting.com
CUSTOMERCONTACT
289
RZB Rudolf Zimmermann, Bamberg GmbH
Rheinstrasse 16 D-96052 Bamberg Germany
Telephone +49 951/79 09-374Fax +49 951/79 09-212
www.rzb.eu [email protected]
KAT3
9EN
emeRGency liGhTinGem
erg
ency
lig
hti
ng
A1