EMC/EMI MEASURING INSTRUMENTS ACCESSORIES · PMM 9010 EMI Receiver 10 Hz - 30 MHz PMM 9010 EMI...
Transcript of EMC/EMI MEASURING INSTRUMENTS ACCESSORIES · PMM 9010 EMI Receiver 10 Hz - 30 MHz PMM 9010 EMI...
EMC/EMI
MEASURING INSTRUMENTS&
ACCESSORIES
SHORT-FORM CATALOG 2010
Our trek started in a small laboratory over25 years ago. Since then, we’ve beenfocused on making EMC measurementseasier and the measuring instrumentsfriendly.We’ve learned. We’ve innovated. For over25 years, we’ve worked to develop perfectEMI/EMC equipment - maybe to the pointof obsession.We adapt new technologies and applyproven engineering principles to createvalue-added solutions for our customers.Combined with our global network ofindependent representatives and distributors, we can support your requirementsall around the world.
ISO 9001:2000 certified Quality Manage-ment System. Accredited as EMC "NotifiedBody” (2004/108/EC directive) and SITCalibration Center Nr. 08, traceable tonational and international accreditationschemes (ISO 17025).
www.pmm.it
PMM 9010/30P EMI Analyzer10 Hz - 3 GHz
• Full CISPR 16-1-1 compliant 9 kHz - 30 MHz• CISPR 16-1-1 compliant RBW & Detectors 30 MHz - 3 GHz• Field upgrade to 3 & 6 GHz full CISPR 16-1-1 compliant• Built-in automatic test routines• Spectrum analyzer mode for debugging• Mostly maintenance and calibration-free• Compact, lightweight, battery operated• Ready for future standards• Powerful PC software included• Compatible with most common EMC Software• Accredited calibration• Ideal for tests according to CISPR 11, 12, 13, 14-1, 15, 22, 25;
EN 55011, 55012, 55013, 55014-1, 55015, 55022, 55025;MIL-STD
All-in-one Digital EMI Analyzer10 Hz - 3 GHz
www.pmm.it
Discontinuous Disturbance(Click) - Analyzer System
Real-time display
Automatic Test Report
• Powerful calibration-free digital design• Exclusive functions to improve test speed• Fully compliant to latest CISPR 16-1-2, CISPR 14-1,
CISPR 11, CISPR 22, EN 55011 55022 55014-1• Basic version embedded in PMM 9010 EMI Receiver• Upgradable at any time
Click $E9010
SIGNAL ANALYZER 9010
USB
PW
Esc
RF OUTPUT 50 W10Hz - 50 MHz
RF INTPUT 50 W10Hz - 30 MHz
0dB
ON
LISN
PMM LISN CONTROL
20 dBAtt. (*)
(*) If required
ACMAINS
EUT
9010 CLICK 4E
Measurement of discontinuousdisturbances on four channels(frequencies) simultaneously
PMM 9010 EMI Receiver10 Hz - 30 MHz
PMM 9010 EMI Receiver with fiber optic link to:
- PMM 9030: 30 MHz - 3 GHz- PMM 9060: 30 MHz - 6 GHz
• Modular approach for all budgets• Eliminates long coax cables• Built-in automatic test routines• Spectrum analyzer mode for debugging• Mostly maintenance and calibration-free• Compact, lightweight, battery operated• Ready for future standards• Powerful PC software included• Compatible with most common EMC Software• Accredited calibration• Ideal for tests according to CISPR 11, 12, 13, 14-1,
15, 22, 25; EN 55011, 55012, 55013, 55014-1,55015, 55022, 55025; MIL-STD
Fully CISPR 16-1-1 CompliantDigital EMC/EMI Receivers10 Hz - 6 GHz
www.pmm.it
RF Generators
RF Power Meter
PMM 30309 kHz - 3 GHz
PMM 30109 kHz - 1 GHz
PMM 66309 kHz - 3 GHz
• Robust design for EMC applications• Easy to use• High output power, +10 dBm• Internal & external AM and Pulse modulations• USB & IEEE-488• Optional rechargeable battery (mod. PMM 3030)• Accredited calibration
• 100 nW - 1 W (-40 to +30 dBm) input range• True RMS response for accurate CW and
modulated power measurements• Internal Reference Calibrator• Lightweight, convenient and easy to use with
desktop and laptop PC• USB connection• Accredited calibration
• User-friendly, cost-effective• Controls and measurements on PC• Ideal for conducted & radiated pre-compliance tests• Built-in 16 A LISN• Spectrum analyzer mode for debugging• Worst points function• Three simultaneous detectors (PK, QP, AVE)
One single click and the test immediately starts! Small,light and affordable by everyone, the PMM 7000
precompliance Receiveris the ideal tool fordebuggingand testing.
PMM 7000
CISPR Pre-compliantEMC/EMI Receiver9 kHz – 1 GHz
www.pmm.it
Conducted ImmunitySystem
• Fully automatic tests according to IEC / EN 61000-4-6;801-3-84 in the frequency range 9 kHz - 230 MHz
• Tests up to 10 V with any CDN• Multi-scan and calibration routines• Closed loop with PMM Power Meter and Current
Probe (option)• Report form included• All included:
- PIMS PC software- RF Generator PMM 3010- RF Amplifier PMM 6000N (10 /15 W)- Single-phase 230 V/16 A CDN M3-16A (*)- Attenuator 25W- Cables kit- Calibration curves 1, 3, 10V
(*) Other CDNs, Injection Clamps and CalibrationKits are available separately.
User-friendly PC Software
PMM 6000S/109 kHz - 230 MHz
PMM Immunity Suite
Radiated ImmunitySystem
The PMM Radiated Immunity System is based on thePMM Immunity Suite (PIMS) software. It controls thefollowing equipments according to the application e.g.TEM, GTEM, Anechoic Chamber:
• RF Generator: PMM 3010 (1 GHz); PMM 3030 (3 GHz)• Field Probes: PMM OR-03; PMM EP-600, EP-601• RF Power Meter: PMM 6630 (3 GHz)
Other application-specific equipments:• RF Amplifier, selected according the required power• One or more antennas• Directional couplers
Highlights:• Automatic tests according to IEC / EN 61000-4-3• Report form included• Multi-scan and calibration routines (16-points grid)• User-friendly
www.pmm.it
• Automatic line switching in conjunction with PMM9010, 9010/30P EMI Receivers
• CISPR 16-1-2 Compliance• Single and three-phase models• Line currents up to 350 A
PMM L2-16ASingle-phase, 230 V/16 A
PMM L3-323-phase 4-wires,400 V/32 A
PMM L3-64, 3-ph.4-wires, 400 V/64 A
LISN - Line ImpedanceStabilization Networks
PMM L3-100, 3-ph.4-wires, 400 V/64 A
• Wide range of Electric and Magnetic Field Probes• Frequency ranges from 100 kHz to 40 GHz• Levels up to 1000 V/m - 20 A/m• PMM OR-03 Optical Repeater to connect to PC• Up to 80 m Optic Fibre• Optical to RS232/USB adapters• Compatible with most common EMC Software• Accredited calibration
Field Probes
Other PMM RF probes with OR-03Optical Repeater
53 m
m o
nly!
• EP-600: 0.15 to 90 V/m, 100 kHz - 9.25 GHz• EP-601: 1 to 300 V/m, 10 kHz - 9.25 GHz• Excellent isotropy - 0.3 dB typ.• 40 m Fiber Optic connection to RS232/USB• Up to 80 hours of continuous operation• Highly reliable Li-Mn rechargeable battery• Direct measurment reading on PC• Compatible with most common EMC Software• Lightweight: 25 g only• Accredited calibration• Ideal for TEM-GTEM cells
Model L1-150M 0,1 - 200 MHz250 VAC/600 VDC, 150 AMulti-standard: ISO 7637-2 • ISO11452-4 • CISPR 16-1-2 • CISPR 25
www.pmm.it
Antenna Sets Antennas
PMM RA-01Active Rod Antenna
9 kHz - 30 MHz
Model AS-02, 30 MHz-3 GHzContains antennas models BC-01, LP-02;Tripod TR-01;5 m RF Cable;CC-01 soft carrying case
Model AS-03, 30 MHz-6 GHzContains antennas models BC-01, LP-02;LP-03; TripodTR-01;5 m RF Cable;CC-01 soft carrying case
• Complete all-includedsolution
• Typical Antenna Factorsstored in PMM EmissionSuite Software
• Individual traceablecalibration (option /TC)
• Cost-effective• Easy to store, carry and
assemble
PMM LP-02Log Periodic Antenna
200 - 3000 MHz
PMM LP-03Log Periodic Antenna
0,8 - 6 GHz
PMM BC-01Biconical Antenna 30 - 200 MHz
www.pmm.it
Magnetic Immunity Test System
Integrated system for tests according to IEC / EN61000-4-8:• Programmable 1200 A current generator with
output feedback• Standard, custom and ramp tests• Autocalibration• Safety interlock and protections• 360° coil rotation angle• Square loop antennas of 1 - 1,5 - 2 m• Rectangular loop antenna 2,6 x 1 m
PMM 1008 with 1x1 m loop antenna
PMM 1008 with 2x2 m loop antenna
A complete solution for measurement of radiofrequency disturbances of electrical lightingequipment according to EN 55015:• Dummy lamps• Large loop antenna• PMM TRF1 Balanced to unbalanced transformer• PMM 9010/9030 EMI Receiver
Radiated power measu-rements of cables takegreat advantages byinstalling the PMM 9030EMI Receiver Unit directlyon the absorbing clamp:• Dramatic reduction of
RF cable length andloss
• Over four hours of continuous operation by battery• Digital Fiber optic link with Main Unit PMM 9010• No ground loops• Noise reduction
G UM
AMN
T
cb
a
d
C
F
a’
b’
c’ d’
a bc d
L
Accessories for EN 55015
Application to EN 55014
Accessories
Voltage probes SHCfor CISPR 16-1-2
Wooden tripods for antennas
and field probes
PL-01 Pulse Limiter suitable foranalog receivers,9 kHz—30 MHz
Calibrations and Services
• Narda Safety Test Solutions S.r.l. isaccredited as EMC "Notified Body"number NB 2050 and SIT CalibrationCenter traceable to national andinternational standards for the elec-trical quantities:
- Frequency- RF power up to 18 GHz- Electromagnetic Field Strength
up to 18 GHz
• Narda STS offers services of calibration for:
- EMI receivers and Spectrum Analyzers- Absorbing Clamps, Current Probes- R.F. Generators and Power Meters- ESD, Burst/Fast Transient and Surge- Magnetic and Electric field sensors- Antennas in O.A.T.S. (Open Area Test
Site)
Narda Safety Test Solutions srlVia Leonardo da Vinci, 21/23 - 20090 Segrate (MI) ITALY
Phone: +39 02 26 998 71 - Fax: +39 02 26 998 700E-Mail: [email protected] - www.narda-sts.it - www.pmm.it
a brand of
Spec
ifica
tio
ns
may
ch
ang
e w
ith
ou
t p
rio
r n
oti
ce -
05/
10