EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology...
Transcript of EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology...
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 1 of 36
EMC Test Report
For Electromagnetic Interference
Of
Product: LED lights bring
Trade Name: OPTONICA
Model Number:
5050-RGBW-60LED-12V-24V, 5050-RGBW-96LED/120LED-24V ,
5050-RGB-60LED/30LED/120LED-12V,
5050-W-60LED/30LED/120LED-12V, 5050-R-60LED/30LED/120LED-12V,
5050-G-60LED/30LED/120LED-12V, 5050-B-60LED/30LED/120LED-12V,
5050-WW-60LED/30LED/120LED-12V,
5050-Pink-60LED/30LED/120LED-12V,
5050-P-60LED/30LED/120LED-12V,
3528-RGB-60LED/120LED/240LED-12V-24V,
3528-W-60LED/120LED/240LED-12V-24V,
3528-WW-60LED/120LED/240LED-12V-24V,
3528-R-60LED/120LED/240LED-12V-24V,
3528-G-60LED/120LED/240LED-12V-24V,
3528-B-60LED/120LED/240LED-12V-24V,
3528-Pink-60LED/120LED/240LED-12V-24V,
3528-P-60LED/120LED/240LED-12V-24V,
5730-W-60LED/120LED-12V-24V,
5730-WW-60LED/120LED-12V-24V,
5730-R-60LED/120LED-12V-24V,
5730-G-60LED/120LED-12V-24V,
5730-B-60LED/120LED-12V-24V,
5730-Pink-60LED/120LED-12V-24V,
5730-P-60LED/120LED-12V-24V,
3014 2835 RGBW.
Prepared for
GUANGZHOU OPTONICA LED CO., LTD
19 QIAODA RD PINGYI INDUSTRY CENTER SHIBI STR PANYU DISTR GUANGZHOU, China.
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 2 of 36
Tested by
Shenzhen ZCT Technology Co., Ltd.
3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899; Fax:86-755-23702323
Reviewed by: Approved by:
Date:2014-09-23 Date:2014-09-23
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 3 of 36
1 Contents
COVER PAGE
Page
1 CONTENTS ................................................................................................................................................................. 3
2 TEST SUMMARY ........................................................................................................................................................ 5
2.1 MEASUREMENT UNCERTAINTY ................................................................................................................................. 6
3 TEST FACILITY .......................................................................................................................................................... 7
3.1 DEVIATION FROM STANDARD ................................................................................................................................... 7
3.2 ABNORMALITIES FROM STANDARD CONDITIONS ......................................................................................................... 7
4 GENERAL INFORMATION ........................................................................................................................................ 7
4.1 GENERAL DESCRIPTION OF EUT ............................................................................................................................ 7
4.1.1 EUT Test Mode ............................................................................................................................................. 8
5 EQUIPMENTS LIST FOR ALL TEST ITEMS .............................................................................................................. 9
6 EMISSION TEST RESULTS ..................................................................................................................................... 10
6.1 MAINS TERMINALS DISTURBANCE VOLTAGE MEASUREMENT ................................................................................... 10
6.1.1 E.U.T. Operation ......................................................................................................................................... 10
6.1.2 Test Specification ....................................................................................................................................... 10
6.1.3 Measurement Data ..................................................................................................................................... 11
6.2 RADIATED ELECTROMAGNETIC DISTURBANCES MEASUREMENT .............................................................................. 12
6.2.1 E.U.T. Operation ......................................................................................................................................... 12
6.2.2 Test Specification ....................................................................................................................................... 12
6.2.3 Measurement Data ..................................................................................................................................... 13
6.3 RADIATED EMISSION MEASUREMENT ..................................................................................................................... 16
6.3.1 E.U.T. Operation ......................................................................................................................................... 16
6.3.2 Test Specification ....................................................................................................................................... 16
6.3.3 Measurement Data ..................................................................................................................................... 17
6.4 HARMONICS ......................................................................................................................................................... 19
6.4.1 E.U.T. Operation ......................................................................................................................................... 19
6.4.2 Test specification ........................................................................................................................................ 19
6.4.3 Measurement Data ..................................................................................................................................... 20
6.5 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER .................................................................................... 20
6.5.1 E.U.T. Operation ......................................................................................................................................... 20
6.5.2 Test specification ........................................................................................................................................ 20
6.5.3 Measurement Data ..................................................................................................................................... 20
7 IMMUNITY TEST RESULTS ..................................................................................................................................... 21
7.1 ELECTROSTATIC DISCHARGE IMMUNITY TEST .......................................................................................................... 21
7.1.1 E.U.T. Operation ......................................................................................................................................... 21
7.1.2 Test specification ........................................................................................................................................ 22
7.1.3 Measurement Data ..................................................................................................................................... 22
7.2 RF FIELD STRENGTH IMMUNITY TEST ..................................................................................................................... 23
7.2.1 E.U.T. Operation ......................................................................................................................................... 23
7.2.2 Test specification ........................................................................................................................................ 24
7.2.3 Measurement Data ..................................................................................................................................... 25
7.3 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST .............................................................................................. 26
7.3.1 E.U.T. Operation ......................................................................................................................................... 26
7.3.2 Test specification ........................................................................................................................................ 26
7.3.3 Measurement Data ..................................................................................................................................... 27
7.4 SURGE IMMUNITY TEST ......................................................................................................................................... 28
7.4.1 E.U.T. Operation ......................................................................................................................................... 28
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 4 of 36
7.4.2 Test specification ........................................................................................................................................ 28 7.4.3 Measurement Data ..................................................................................................................................... 29
7.5 CONDUCTED DISTURBANCE IMMUNITY TEST ............................................................................................................ 30
7.5.1 E.U.T. Operation ......................................................................................................................................... 30
7.5.2 Test specification ........................................................................................................................................ 30
7.5.3 Measurement Data ..................................................................................................................................... 31
7.6 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST ............................................................................................ 32
7.6.1 E.U.T. Operation ......................................................................................................................................... 32
7.6.2 Test specification ........................................................................................................................................ 32
7.6.3 Measurement Data ..................................................................................................................................... 33
7.7 VOLTAGE DIPS AND INTERRUPTIONS IMMUNITY TEST ................................................................................................ 34
7.7.1 E.U.T. Operation ......................................................................................................................................... 34
7.7.2 Test specification ........................................................................................................................................ 34
7.7.3 Measurement Data ..................................................................................................................................... 35
8 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS .................................................................. 36
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 5 of 36
2 Test Summary
Test procedures according to the technical standards:
EMC Emission
Standard
Test Item
Limit
Judgment
Remark
EN 55015:2013
Conducted Emission
/
N/A
Radiated Emission
/
PASS
EN61000-3-2:2006+A2:2009
Harmonic Current Emission
Class C
N/a
EN 61000-3-3:2013
Voltage Fluctuations & Flicker
------
N/A
EMC Immunity
Section EN 61547:2009
Test Item Performance
Criteria
Judgment
Remark
EN 61000-4-2:2009
Electrostatic Discharge
B
PASS
EN 61000-4-3:2006+A1:2008+A2:20
10
RF electromagnetic field
A
PASS
EN 61000-4-4:2012
Fast transients
B
PASS
EN 61000-4-5:2006
Surges
B
PASS
EN 61000-4-6:2012
Injected Current
A
PASS
EN 61000-4-8:2010 Power Frequency Magnetic
Field
A
PASS
EN 61000-4-11:2004
Volt. Interruptions Volt. Dips B / C NOTE (2)
PASS
NOTE:
(1)” N/A” denotes test is not applicable in this Test Report
(2) Voltage dip: 100% reduction – Performance Criteria B
Voltage dip: 30% reduction – Performance Criteria C
(3) For client’s request and manual description, the test will not be executed.
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 6 of 36
2.1 Measurement Uncertainty
The report uncertainty of measurement y ± U , where expended uncertainty U is based on a standard uncertainty Multiplied by a coverage factor of k=2 , providing a level of confidence of approximately 95% .
No.
Item
Frequency Range
U , Value
1
Power Line Conducted Emission (Conduction 1)
150KHz~30MHz
1.58 dB
2
Power Line Conducted Emission (Conduction 2)
150KHz~30MHz
2.00 dB
3
Disturbance Power Emission (Conduction 1)
30MHz~300MHz
3.12 dB
4
Radiated Emission Test
30MHz~1GHz
3.40 dB
5
Radiated Emission Test
1GHz~18GHz
3.30 dB
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 7 of 36
3 Test Facility
Hang Zhou ZJU Interlogic Co., Ltd No. 4004, 14th Floor,XuSheng Building,Bao'an Road, Bao'an District, Shenzhen,Guangdong,China.
3.1 Deviation from standard
None
3.2 Abnormalities from standard conditions
None
4 General Information
4.1 General Description of EUT
Manufacturer: GUANGZHOU OPTONICA LED CO., LTD
Manufacturer Address:
19 QIAODA RD PINGYI INDUSTRY CENTER SHIBI STR PANYU DISTR GUANGZHOU, CHINA.
EUT Name:
LED lights strips
Brand Name:
OPTONICA
Test Model No:
5050-RGBW-60LED-12V-24V
Serial No:
5050-RGBW-96LED/120LED-24V , 5050-RGB-60LED/30LED/120LED-12V,
5050-W-60LED/30LED/120LED-12V, 5050-R-60LED/30LED/120LED-12V,
5050-G-60LED/30LED/120LED-12V, 5050-B-60LED/30LED/120LED-12V,
5050-WW-60LED/30LED/120LED-12V, 5050-Pink-60LED/30LED/120LED-12V,
5050-P-60LED/30LED/120LED-12V,
3528-RGB-60LED/120LED/240LED-12V-24V,
3528-W-60LED/120LED/240LED-12V-24V,
3528-WW-60LED/120LED/240LED-12V-24V,
3528-R-60LED/120LED/240LED-12V-24V,
3528-G-60LED/120LED/240LED-12V-24V,
3528-B-60LED/120LED/240LED-12V-24V,
3528-Pink-60LED/120LED/240LED-12V-24V,
3528-P-60LED/120LED/240LED-12V-24V, 5730-W-60LED/120LED-12V-24V,
5730-WW-60LED/120LED-12V-24V, 5730-R-60LED/120LED-12V-24V,
5730-G-60LED/120LED-12V-24V, 5730-B-60LED/120LED-12V-24V,
5730-Pink-60LED/120LED-12V-24V, 5730-P-60LED/120LED-12V-24V, 3014 2835 RGBW.
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 8 of 36
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Power Supply Range: 12-24VDC 10W
Test Power Supply:
24VDC
4.1.1 EUT Test Mode
Mode 1 Lighting/Running
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 9 of 36
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
5 Equipments List for All Test Items
No.
Equipment
Manufacturer
Model No.
S/N
Cal date
1
EMI Test Receiver
R&S
ESCI
100612
2014-7-01
2
EMI Test Receiver
R&S
ESPI
100067
2014-7-01
3
Amplifier
HP
8447D
1937A02415
2014-7-01
4
Single Power Conductor
Module
FCC
FCC-LISN-5-50-
1-01-CISPR25
07118
2014-7-01
5
TRILOG Broadband
Test-Antenna
SCHWARZBECK
VULB9163
9163-387
2014-7-01
6
Horn Antenna
SCHWARZBECK
BBHA9120A
B08000991-0021
2014-7-01
7
High Field Biconical Antenna
ELECTRO-METRICS
EM-6913
169
2014-7-01
8
Log Periodic Antenna
ELECTRO-METRICS
EM-6950
818
2014-7-01
9
Remote Active Vertical Antenna
ELECTRO-METRICS
EM-6892
354
2014-7-01
10
Power Clamp
SCHWARZBECK
MDS-21
3898
2014-7-01
11
Single Power Conductor Module
FCC
FCC-LISN-5-50-
1-01-CISPR25
07254
2014-7-01
12
Teo Line Single Phase Module
SCHWARZBECK
NSLK8128
D-69124
2014-7-01
13
Positioning Controller
C&C
CC-C-1F
MF7802155
2014-7-01
14
`Electrostatic Discharge
Simulator
TESEQ
NSG437
128
2014-7-01
15
Fast Transient Burst Generator
SCHAFFNER
MODULA6150
34587
2014-7-01
16
Fast Transient Noise Simulator
Noiseken
FNS-105AX
31438
2014-7-01
17
Capacitive Coupling Clamp
TESEQ
CDN8014
25115
2014-7-01
18
Color TV Pattern Genenator
PHILIPS
PM5418
TM209966
N/A
19
Power Frequency Magnetic
Field Gene
EVERFINE
EMS61000-8K
608085
2014-7-01
20
Triple-Loop Antenna
EVERFINE
LLA-2
607035
2014-7-01
21
10dB attenuator
SCHWARZBECK
MTAIMP-136
R65.90.0009
2014-7-01
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 10 of 36
6 Emission Test Results
6.1 Mains Terminals Disturbance Voltage Measurement
Frequency (MHz)
Class A (dBμV) Class B (dBμV)
Q.P. (Quasi-Peak) A.V. (Average) Q.P. (Quasi-Peak) A.V. (Average)
0.15 ~ 0.50 79 66 66 to 56 56 to 46
0.50 ~ 5.0 73 60 56 46
5.0 ~ 30 73 60 60 50
Detector:
Peak for pre-scan (9kHz Resolution Bandwidth)
Quasi-Peak & Average if maximized peak within 6dB of Average Limit
6.1.1 E.U.T. Operation
Temperature:
23C
Humidity:
55% RH
Atmospheric Pressure:
101
Kpa
Test Mode:
Mode 1
The Worst Mode:
Mode 1
6.1.2 Test Specification 40cm V.C.P.
EUT
80cm Pulse Limiter Test Receiver
H.C.P. LISN
EUT was placed upon a wooden test table 0.8m above the horizontal metal reference plane and 0.4m from
the vertical ground plane, and it was connected to an AMN. The closest distance between the boundary of
the EUT and the surface of the AMN is 0.8m. All peripherals were connected to another AMN, and placed at a
distance of 10cm from each other. A spectrum and receiver was connected to the RF output port of the AMN.
Both average and quasi-peak value were detected.
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 11 of 36
6.1.3 Measurement Data
An initial pre-scan was performed on the live and neutral lines.
Quasi-peak or average measurements were performed at the frequency which maximum peak emissions were detected.
Please refer to the attached quasi-peak & average measurement data for reference.
Operating mode: Mode 1
Frequency Factor Meter Reading (dBμV) Emission Level (dBμV) Limits (dBμV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.1620 11.68 39.16 34.59 50.84 46.07 65.36 54.77 -14.52 -8.70
0.2300 10.95 37.24 32.46 48.19 43.41 62.45 52.45 -14.26 -9.04
0.2900 10.76 34.36 31.23 45.12 41.99 60.52 50.52 -15.40 -8.53
2.1940 10.17 32.04 29.48 42.21 39.65 56.00 46.00 -13.79 -6.35
*3.9220 10.17 40.98 31.52 51.15 41.69 56.00 46.00 -4.85 -4.31
10.3820 1.26 43.71 42.47 44.97 43.73 60.00 50.00 -15.03 -6.27
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
3. ‘*’ means the worst case
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 12 of 36
6.2 Radiated Electromagnetic Disturbances Measurement
Frequency Range:
9kHz to 30MHz
Limits of Radiated Emission Measurement
Frequency
2m 3m 4m
dB(μA)
dB(μA)
dB(μA)
9 KHz~ 70 KHz 88 81 75
70 KHz ~ 150 KHz 88 to 58 81 to 51 75 to 45
150 KHz ~ 3 MHz 58 to 22 51 to 15 45 to 9
3 MHz ~ 30 MHz 22 15 to 16 9 to 12
Detector:
Peak for pre-scan
Quasi-Peak if maximum peak within 6dB of limit
6.2.1 E.U.T. Operation
Temperature:
22C
Humidity:
51% RH
Atmospheric Pressure:
101
Kpa
Test Mode:
Mode 1
The Worst Mode:
Mode 1
6.2.2 Test Specification
EUT was placed upon a wooden test table which was placed in the center of the test antenna, and operating
in the mode as mentioned above. A receiver is used to detect the actual value of each frequency which need
to be checked. All three field directions were measured in sequence.
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 13 of 36
6.2.3 Measurement Data
An initial pre-scan was performed using the receiver in peak detection mode. The EUT was measured by 3
antenna position and peak emissions from the EUT were detected within 6dB of the class B limit line.
The following quasi-peak measurements were performed on the EUT.
Antenna
Position
Frequency
(MHz)
Cable Loss
(dB)
QP Reading
(dBµA)
QP Level
(dBµA)
Margin
(dB)
Limits
(dBµA)
A1
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
A2
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
A3
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Note: ‘*’ means the disturbance power level 20dB lower than the relevant limit.
QP Level = QP Reading + Cable Loss
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 14 of 36
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 15 of 36
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 16 of 36
Frequency (MHz)
Class A (10m) Class B (3m)
Quasi-Peak
dB(μV/m)
Quasi-Peak
dB(μV/m)
30 ~ 230 40.0 40.0
230 ~ 300 47.0 47.0
6.3 Radiated Emission Measurement
Limits of Radiated Emission Measurement (Below 1GHz)
Detector:
Peak for pre-scan (120kHz resolution bandwidth) Quasi-Peak if maximum peak within 6dB of limit
6.3.1 E.U.T. Operation
Temperature:
24C
Humidity:
52% RH
Atmospheric Pressure:
101
Kpa
Test Mode:
Mode 1
The Worst Mode:
Mode 1
6.3.2 Test Specification
3 m
1~ 4 m
EUT
80 cm
Test Receiver Amp
EUT was placed upon a wooden test table which was placed on the turn table 0.8m above the horizontal metal
ground plane, and operating in the mode as mentioned above. A receiving antenna was placed 3m away from
the EUT. During testing, turn around the turn table and move the antenna from 1m to 4m to find the maximum
field-strength reading. All peripherals were placed at a distance of 10cm between each other. Both horizontal
and vertical antenna polarities were tested.
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 17 of 36
6.3.3 Measurement Data
An initial pre-scan was performed in the 3m chamber using the spectrum analyzers in peak detection mode.
The EUT was measured by Biology antenna with 2 orthogonal polarities and peak emissions from the EUT
were detected within 6dB of the class B limit line.
The following quasi-peak measurements were performed on the EUT.
Horizontal -- Input: DC24V Operating mode: Mode 1
Frequency Factor Meter Reading Emission Level Margin Limits
(MHz) (dB) (dBμV) (dBμV/m) (dB) (dBμV/m)
239.520** 15.160 4.058 19.218 -27.782 47.000
335.550** 18.150 2.467 20.617 -26.383 47.000
363.680** 18.820 2.268 21.088 -25.912 47.000
431.580** 20.750 6.469 27.219 -19.781 47.000
527.610** 22.810 3.906 26.716 -20.284 47.000
748.770** 27.960 2.558 30.518 -16.482 47.000
Remark:
1. “ * ” Mark means readings are Peak Values.
2. “ ** “ Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss – Pre-amplifier.
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 18 of 36
VERTICAL -- Input: DC24V Operating mode: Mode 1
Frequency Factor Meter Reading Emission Level Margin Limits
(MHz) (dB) (dBμV) (dBμV/m) (dB) (dBμV/m)
335.550** 18.150 1.896 20.046 -26.954 47.000
363.680** 18.820 3.120 21.940 -25.060 47.000
431.580** 20.750 6.524 27.274 -19.726 47.000
527.610** 22.810 2.984 25.794 -21.206 47.000
748.770** 27.960 2.495 30.455 -16.545 47.000
978.660** 30.300 6.183 36.483 -10.517 47.000
Remark:
1. “ * ” Mark means readings are Peak Values.
2. “ ** “ Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss – Pre-amplifier.
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 19 of 36
6.4 Harmonics
Frequency Range:
100Hz to 2kHz
Test Requirement:
EN 61000-3-2
6.4.1 E.U.T. Operation
Temperature:
22C
Humidity:
50% RH
Atmospheric Pressure:
101
Kpa
Test Mode:
Mode 1
The Worst Mode:
Mode 1
6.4.2 Test specification
EUT operated in the mode as mentioned above, and connected to Harmonic/Flicker measuring equipment
which was connected to an AC power source. Measurement was performed after EUT operating in static
state for 10 seconds. Each order harmonics found to meet the relevant limits.
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 20 of 36
6.4.3 Measurement Data PASS
6.5 Voltage changes, voltage fluctuations and flicker
Test Requirement:
EN 61000-3-3
6.5.1 E.U.T. Operation
Temperature:
22C
Humidity:
50% RH
Atmospheric Pressure:
101
Kpa
Test Mode:
Mode 1
The Worst Mode:
Mode 1
6.5.2 Test specification
EUT was operated in the mode as mentioned above, and connected to Harmonic/Flicker measuring
equipment which was connected to an AC power source.
6.5.3 Measurement Data
PASS
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 21 of 36
7 Immunity Test Results
7.1 Electrostatic discharge immunity test
Acceptable
Performance Criterion:
B
Discharge Impedance:
330 / 150 pF
Discharge Voltage:
Air Discharge: ±8 kV
Contact Discharge: ±4 kV
VCP, HCP: ±4 kV
Polarity:
Positive & Negative
Minimum discharge Interval:
1 second
7.1.1 E.U.T. Operation
Temperature:
24C
Humidity:
48% RH
Atmospheric Pressure:
101
Kpa
Test Mode:
Mode 1
The Worst Mode:
Mode 1
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 22 of 36
7.1.2 Test specification
EUT was operated in the mode as mentioned above. Both contact and air discharge was executed. Contact
discharge to the conductive surfaces and to coupling planes; air discharge at insulating surfaces. Each test
point shall be subjected to 10 discharges at least (For each voltage and polarity).
7.1.3 Measurement Data
Form:AMC 410-6
Test Record
Electrostatic Discharge Test Results
Applicant : GUANGZHOU OPTONICA
LED CO., LTD
EUT:LED lights strips
M/N:5050-RGBW-60LED-12V-24V
Test Voltage:Input: DC24V
Test Date:Sep. 21, 2014
IEC61000-4-2
EN61000-4-2
other:
Test Result: Pass Fail
Temp: 24 C Humi: 48
% Atmospheric Pressure:
101 Kpa
Operating Mode
1
Discharge times
Contact discharge: minimum 10 times (+/-respectively) at each point,
Air discharge: minimum 10 times (+/- respectively) at each point.
Discharge Mode
Air Discharge
Contact Discharge
Performance
Criterion
Result
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 23 of 36
Test level (kV) 4 8 10 15 2 4 6 8
Test Location + - + - + - + - + - + - + - + -
HCP
A
A
B
Pass
VCP
A
A
Pass
A1
B
B
Pass
A2
B
B
Pass
Note: “P” means Pass , Horizontal Coupling Plane(HCP) and Vertical Coupling plane(VCP).
7.2 RF field strength immunity test
Acceptable
Performance Criterion:
A
Test Level
3 V/m
Test Distance
3 m
Frequency Range
80MHz~1000MHz
Polarity:
Horizontal & Vertical
7.2.1 E.U.T. Operation
Temperature:
24C
Humidity:
52% RH
Atmospheric Pressure:
101
Kpa
Test Mode:
Mode 1
The Worst Mode:
Mode 1
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 24 of 36
7.2.2 Test specification
Test was executed in a fully Anechoic chamber. An antenna was used to transmit interference signal. EUT
was placed upon a wooden table above the reference ground 0.8m, and was positioned so that the four sides
of the EUT shall be exposed to the electromagnetic field in a sequence. In each position the performance of
the EUT was investigated. A camera was used to monitor the loss of function or degradation of performance
of the EUT.
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 25 of 36
7.2.3 Measurement Data
Form:AMC410-7
Test Record
Radiated Frequency Field Strength Susceptibility Results
Applicant : GUANGZHOU OPTONICA
LED CO., LTD
EUT:LED lights strips
M/N:5050-RGBW-60LED-12V-24V
Test Voltage:Input: DC24V
Test Date:Sep. 21, 2014
IEC61000-4-3
EN61000-4-3
other:
Test Result: Pass Fail
Temp: 24 C Humi: 52 %
Atmospheric Pressure: 101 Kpa
Test Port Enclosure
Operating
Mode
Mode 1
Test Level
3 V/m(r.m.s) ( unmodulated )
Criteri
on
Frequency Range(MHZ)
Antenna polarity
Modulation
EUT
positio
n
Result
80~1000
Horizontal
1KHz,
80% AM
Front
Pass
Rear
Pass
Left
Pass
Right
Pass
80~1000
Vertical
1KHz,
80% AM
Front
Pass
Rear
Pass
Left
Pass
Right
Pass
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 26 of 36
7.3 Electrical fast transient/burst immunity test
Acceptable
Performance Criterion:
B
Test Level:
0.5, 1.0, kV on AC Line; 0.5 kV on Signal Line
Repetition Frequency:
5 kHz
Burst Duration:
300 ms
Test Duration:
1 minutes for each level & polarity
7.3.1 E.U.T. Operation
Temperature:
24C
Humidity:
48% RH
Atmospheric Pressure:
101
Kpa
Test Mode:
Mode 1
The Worst Mode:
Mode 1
7.3.2 Test specification
EUT was placed on a metal ground reference plane and was insulated from it by a wooden support which is
0.1m thick. The ground reference plane is connected to the protective earth. The test generator and the
coupling/decoupling network were placed directly on, and bonded to the ground reference plane.
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 27 of 36
7.3.3 Measurement Data
Form:AMC 410-8
Test Record
Electrical Fast Transient/Burst Result
Applicant : GUANGZHOU OPTONICA
LED CO., LTD
EUT:LED lights strips
M/N:5050-RGBW-60LED-12V-24V
Test Voltage:Input: DC24V
Test Date:Sep. 21, 2014
IEC61000-4-4
EN61000-4-4
other:
Test Result: Pass Fail
Temp: 24 C Humi: 48 %
Atmospheric Pressure: 101 Kpa
Test Signal
Rise time: 5ns, Duration: 50ns, repetition rate : 5KHz 100KHz
Coupling Line
Test level (kV)
Performance
Criterion
Resul
t 0.5 1 2 4
+ - + - + - + -
A
C
lin
e
L
A
A
B
Pass
N A A Pass
PE
L+N A A Pass
L+PE
N+PE
L+N+PE
DC Line
Signal Line
Note:
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 28 of 36
7.4 Surge immunity test
Acceptable
Performance Criterion:
B
Test Level:
0.5, 1kV Line to Neutral
0.5, 1, 2kV Line, Neutral to Earth
Polarity:
Positive & Negative
Generator source impedance:
2 Ω & 12 Ω
Trigger Mode:
Internal
No. of surges:
5 positive & 5 negative at 0, 90, 180, 270.
7.4.1 E.U.T. Operation
Temperature:
23C
Humidity:
51% RH
Atmospheric Pressure:
101
Kpa
Test Mode:
Mode 1
The Worst Mode:
Mode 1
7.4.2 Test specification
EUT was placed on a wooden table which is 0.8m above the ground and operated in the mode as mentioned
above. The power cord between the EUT and the coupling/decoupling network was bundled so as to make it
less than 2 m in length.
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 29 of 36
7.4.3 Measurement Data
Form:AMC 410-9
Test Record
Surge Immunity Test Result
Applicant : GUANGZHOU OPTONICA
LED CO., LTD
EUT:LED lights strips
M/N:5050-RGBW-60LED-12V-24V
Test Voltage:Input: DC24V
Test Date:Sep. 21, 2014
IEC61000-4-5
EN61000-4-5
other:
Test Result: Pass Fail
Temp: 24 C Humi: 50 %
Atmospheric Pressure: 101 Kpa
Test Signal
1.2/50 μs 10/700μs
Interval: 120 seconds Pluse: 5 times
Coupling Line
Test level Performance
Criterion
Result 0.5 kV 1 kV 2 kV 4 kV
+ - + - + - + -
A
C
li
n
e
L-N
0°
B
90° A PASS
180°
270° A PASS
L-PE
0°
90°
180°
270°
N-PE
0°
90°
180°
270°
DC Line
Signal Line
Note:
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 30 of 36
7.5 Conducted disturbance immunity Test
Acceptable
Performance Criterion:
A
Test Level
3 V
Frequency Range
0.150MHz~80MHz
7.5.1 E.U.T. Operation
Temperature:
24C
Humidity:
50% RH
Atmospheric Pressure:
101
Kpa
Test Mode:
Mode 1
The Worst Mode:
Mode 1
7.5.2 Test specification
The equipment to be tested was placed on an insulating support of 0,1m height above a ground reference
Plane. The minimum distance between the EUT and all other conductive structures, except the ground
reference plane is more than 0.5m. All relevant cables were provided with the appropriate coupling and
decoupling devices at a distance between 0.1m and 0.3m from the projected geometry of the EUT.
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 31 of 36
7.5.3 Measurement Data
Form:AMC 410-10
Test Record
Injected Currents Susceptibility Measurement Result
Applicant : GUANGZHOU OPTONICA
LED CO., LTD
EUT:LED lights strips
M/N:5050-RGBW-60LED-12V-24V
Test Voltage:Input: DC24V
Test Date:Sep. 21, 2014
IEC61000-4-6
EN61000-4-6
other:
Test Result: Pass Fail
Temp: 24 C Humi: 50 %
Atmospheric Pressure: 101 Kpa
Test Port
AC Port
Operating
Mode
Mode 1
Test
Leve
l (V)
3 V(r.m.f) ( unmodulated )
Criterion
A
Step Size 1 % Dwell Time(S)
1
Frequency Range
(MHz)
Modulation
Result
0.15~80
1 KHz,
80 % AM
Pass
KHz,
% AM
Note:
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 32 of 36
7.6 Power frequency magnetic field immunity test
Acceptable
Performance Criterion:
A
Test Level:
1 A/m
Coil Orientation:
X & Y & Z
Test Duration:
5 Minutes for each orientation
7.6.1 E.U.T. Operation
Temperature:
20C
Humidity:
52% RH
Atmospheric Pressure:
101
Kpa
Test Mode:
Mode 1
The Worst Mode:
Mode 1
7.6.2 Test specification
The equipment is configured and connected to satisfy its functional requirements. It was placed on the ground
reference plane with the interposition of a 0.1 m thickness wooden support and was placed in the center of the
induction coil. All cables (include power cord and signal line) were exposed to the magnetic field for at least
1m of their length.
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 33 of 36
7.6.3 Measurement Data
Form:AMC 410-14
Test Record
Power Frequency Magnetic Field Immunity Test Results
Applicant : GUANGZHOU OPTONICA
LED CO., LTD
EUT:LED lights strips
M/N:5050-RGBW-60LED-12V-24V
Test Voltage:Input: DC24V
Test Date:Sep. 21, 2014
IEC61000-4-8
EN61000-4-8
other:
Test Result: Pass Fail
Temp: 24 C Humi: 50 %
Atmospheric Pressure: 101 Kpa
Operating
Mode
Mode 1
Test Level
Test Duration
Coil Orientation
Criterion
Result
1 A/m
5 minus
X
A
Pass
1 A/m
5 minus
Y
A
Pass
1 A/m
5 minus
Z
A
Pass
Note:
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 34 of 36
7.7 Voltage dips and interruptions immunity test
Acceptable
Performance Criterion:
B & C
Test Level:
<5% of UT (Supply Voltage) for 0.5 and 250 Periods
70 % of UT (Supply Voltage) for 25 Periods
No. of Dips / Interruptions:
3 per Level
7.7.1 E.U.T. Operation
Temperature:
22C
Humidity:
47% RH
Atmospheric Pressure:
101
Kpa
Test Mode:
Mode 1/ Mode 2/ Mode 3/ Mode 4
The Worst Mode:
Mode 1
7.7.2 Test specification
EUT connected to the test generator with the shortest power supply cable as specified by the EUT
manufacturer. The rated voltage of the EUT was used as the basis for voltage test level specification. After
each group of tests, a full functional check was performed.
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 35 of 36
7.7.3 Measurement Data
Form:AMC 410-11
Test Record
Voltage Dips And Interruptions Test Result
Applicant : GUANGZHOU OPTONICA
LED CO., LTD
EUT:LED lights strips
M/N:5050-RGBW-60LED-12V-24V
Test Voltage:Input: DC24V
Test Date:Sep. 21, 2014
IEC61000-4-11
EN61000-4-11
other:
Test Result: Pass Fail
Temp: 24 C Humi: 50 %
Atmospheric Pressure: 101 Kpa
Test Port
AC Port
Operating
Mode
Mode 1
Level
(%UT)
Interruption &
Dips(%UT)
Duration
(Cyc)
Phase
Criterion
Result
70 30 10 90 C PASS
0 100 0.5 180 B PASS
Note:None
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01
Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.
Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com
Page 36 of 36
8 APPENDIX-Photographs of EUT Constructional Details
****End of Report****