EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology...

36
Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China. Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com Page 1 of 36 EMC Test Report For Electromagnetic Interference Of ProductLED lights bring Trade Name: OPTONICA Model Number5050-RGBW-60LED-12V-24V, 5050-RGBW-96LED/120LED-24V , 5050-RGB-60LED/30LED/120LED-12V, 5050-W-60LED/30LED/120LED-12V, 5050-R-60LED/30LED/120LED-12V, 5050-G-60LED/30LED/120LED-12V, 5050-B-60LED/30LED/120LED-12V, 5050-WW-60LED/30LED/120LED-12V, 5050-Pink-60LED/30LED/120LED-12V, 5050-P-60LED/30LED/120LED-12V, 3528-RGB-60LED/120LED/240LED-12V-24V, 3528-W-60LED/120LED/240LED-12V-24V, 3528-WW-60LED/120LED/240LED-12V-24V, 3528-R-60LED/120LED/240LED-12V-24V, 3528-G-60LED/120LED/240LED-12V-24V, 3528-B-60LED/120LED/240LED-12V-24V, 3528-Pink-60LED/120LED/240LED-12V-24V, 3528-P-60LED/120LED/240LED-12V-24V, 5730-W-60LED/120LED-12V-24V, 5730-WW-60LED/120LED-12V-24V, 5730-R-60LED/120LED-12V-24V, 5730-G-60LED/120LED-12V-24V, 5730-B-60LED/120LED-12V-24V, 5730-Pink-60LED/120LED-12V-24V, 5730-P-60LED/120LED-12V-24V, 3014 2835 RGBW. Prepared for GUANGZHOU OPTONICA LED CO., LTD 19 QIAODA RD PINGYI INDUSTRY CENTER SHIBI STR PANYU DISTR GUANGZHOU, China.

Transcript of EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology...

Page 1: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 1 of 36

EMC Test Report

For Electromagnetic Interference

Of

Product: LED lights bring

Trade Name: OPTONICA

Model Number:

5050-RGBW-60LED-12V-24V, 5050-RGBW-96LED/120LED-24V ,

5050-RGB-60LED/30LED/120LED-12V,

5050-W-60LED/30LED/120LED-12V, 5050-R-60LED/30LED/120LED-12V,

5050-G-60LED/30LED/120LED-12V, 5050-B-60LED/30LED/120LED-12V,

5050-WW-60LED/30LED/120LED-12V,

5050-Pink-60LED/30LED/120LED-12V,

5050-P-60LED/30LED/120LED-12V,

3528-RGB-60LED/120LED/240LED-12V-24V,

3528-W-60LED/120LED/240LED-12V-24V,

3528-WW-60LED/120LED/240LED-12V-24V,

3528-R-60LED/120LED/240LED-12V-24V,

3528-G-60LED/120LED/240LED-12V-24V,

3528-B-60LED/120LED/240LED-12V-24V,

3528-Pink-60LED/120LED/240LED-12V-24V,

3528-P-60LED/120LED/240LED-12V-24V,

5730-W-60LED/120LED-12V-24V,

5730-WW-60LED/120LED-12V-24V,

5730-R-60LED/120LED-12V-24V,

5730-G-60LED/120LED-12V-24V,

5730-B-60LED/120LED-12V-24V,

5730-Pink-60LED/120LED-12V-24V,

5730-P-60LED/120LED-12V-24V,

3014 2835 RGBW.

Prepared for

GUANGZHOU OPTONICA LED CO., LTD

19 QIAODA RD PINGYI INDUSTRY CENTER SHIBI STR PANYU DISTR GUANGZHOU, China.

Page 2: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 2 of 36

Tested by

Shenzhen ZCT Technology Co., Ltd.

3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899; Fax:86-755-23702323

Reviewed by: Approved by:

Date:2014-09-23 Date:2014-09-23

Page 3: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 3 of 36

1 Contents

COVER PAGE

Page

1 CONTENTS ................................................................................................................................................................. 3

2 TEST SUMMARY ........................................................................................................................................................ 5

2.1 MEASUREMENT UNCERTAINTY ................................................................................................................................. 6

3 TEST FACILITY .......................................................................................................................................................... 7

3.1 DEVIATION FROM STANDARD ................................................................................................................................... 7

3.2 ABNORMALITIES FROM STANDARD CONDITIONS ......................................................................................................... 7

4 GENERAL INFORMATION ........................................................................................................................................ 7

4.1 GENERAL DESCRIPTION OF EUT ............................................................................................................................ 7

4.1.1 EUT Test Mode ............................................................................................................................................. 8

5 EQUIPMENTS LIST FOR ALL TEST ITEMS .............................................................................................................. 9

6 EMISSION TEST RESULTS ..................................................................................................................................... 10

6.1 MAINS TERMINALS DISTURBANCE VOLTAGE MEASUREMENT ................................................................................... 10

6.1.1 E.U.T. Operation ......................................................................................................................................... 10

6.1.2 Test Specification ....................................................................................................................................... 10

6.1.3 Measurement Data ..................................................................................................................................... 11

6.2 RADIATED ELECTROMAGNETIC DISTURBANCES MEASUREMENT .............................................................................. 12

6.2.1 E.U.T. Operation ......................................................................................................................................... 12

6.2.2 Test Specification ....................................................................................................................................... 12

6.2.3 Measurement Data ..................................................................................................................................... 13

6.3 RADIATED EMISSION MEASUREMENT ..................................................................................................................... 16

6.3.1 E.U.T. Operation ......................................................................................................................................... 16

6.3.2 Test Specification ....................................................................................................................................... 16

6.3.3 Measurement Data ..................................................................................................................................... 17

6.4 HARMONICS ......................................................................................................................................................... 19

6.4.1 E.U.T. Operation ......................................................................................................................................... 19

6.4.2 Test specification ........................................................................................................................................ 19

6.4.3 Measurement Data ..................................................................................................................................... 20

6.5 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER .................................................................................... 20

6.5.1 E.U.T. Operation ......................................................................................................................................... 20

6.5.2 Test specification ........................................................................................................................................ 20

6.5.3 Measurement Data ..................................................................................................................................... 20

7 IMMUNITY TEST RESULTS ..................................................................................................................................... 21

7.1 ELECTROSTATIC DISCHARGE IMMUNITY TEST .......................................................................................................... 21

7.1.1 E.U.T. Operation ......................................................................................................................................... 21

7.1.2 Test specification ........................................................................................................................................ 22

7.1.3 Measurement Data ..................................................................................................................................... 22

7.2 RF FIELD STRENGTH IMMUNITY TEST ..................................................................................................................... 23

7.2.1 E.U.T. Operation ......................................................................................................................................... 23

7.2.2 Test specification ........................................................................................................................................ 24

7.2.3 Measurement Data ..................................................................................................................................... 25

7.3 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST .............................................................................................. 26

7.3.1 E.U.T. Operation ......................................................................................................................................... 26

7.3.2 Test specification ........................................................................................................................................ 26

7.3.3 Measurement Data ..................................................................................................................................... 27

7.4 SURGE IMMUNITY TEST ......................................................................................................................................... 28

7.4.1 E.U.T. Operation ......................................................................................................................................... 28

Page 4: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 4 of 36

7.4.2 Test specification ........................................................................................................................................ 28 7.4.3 Measurement Data ..................................................................................................................................... 29

7.5 CONDUCTED DISTURBANCE IMMUNITY TEST ............................................................................................................ 30

7.5.1 E.U.T. Operation ......................................................................................................................................... 30

7.5.2 Test specification ........................................................................................................................................ 30

7.5.3 Measurement Data ..................................................................................................................................... 31

7.6 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST ............................................................................................ 32

7.6.1 E.U.T. Operation ......................................................................................................................................... 32

7.6.2 Test specification ........................................................................................................................................ 32

7.6.3 Measurement Data ..................................................................................................................................... 33

7.7 VOLTAGE DIPS AND INTERRUPTIONS IMMUNITY TEST ................................................................................................ 34

7.7.1 E.U.T. Operation ......................................................................................................................................... 34

7.7.2 Test specification ........................................................................................................................................ 34

7.7.3 Measurement Data ..................................................................................................................................... 35

8 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS .................................................................. 36

Page 5: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 5 of 36

2 Test Summary

Test procedures according to the technical standards:

EMC Emission

Standard

Test Item

Limit

Judgment

Remark

EN 55015:2013

Conducted Emission

/

N/A

Radiated Emission

/

PASS

EN61000-3-2:2006+A2:2009

Harmonic Current Emission

Class C

N/a

EN 61000-3-3:2013

Voltage Fluctuations & Flicker

------

N/A

EMC Immunity

Section EN 61547:2009

Test Item Performance

Criteria

Judgment

Remark

EN 61000-4-2:2009

Electrostatic Discharge

B

PASS

EN 61000-4-3:2006+A1:2008+A2:20

10

RF electromagnetic field

A

PASS

EN 61000-4-4:2012

Fast transients

B

PASS

EN 61000-4-5:2006

Surges

B

PASS

EN 61000-4-6:2012

Injected Current

A

PASS

EN 61000-4-8:2010 Power Frequency Magnetic

Field

A

PASS

EN 61000-4-11:2004

Volt. Interruptions Volt. Dips B / C NOTE (2)

PASS

NOTE:

(1)” N/A” denotes test is not applicable in this Test Report

(2) Voltage dip: 100% reduction – Performance Criteria B

Voltage dip: 30% reduction – Performance Criteria C

(3) For client’s request and manual description, the test will not be executed.

Page 6: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 6 of 36

2.1 Measurement Uncertainty

The report uncertainty of measurement y ± U , where expended uncertainty U is based on a standard uncertainty Multiplied by a coverage factor of k=2 , providing a level of confidence of approximately 95% .

No.

Item

Frequency Range

U , Value

1

Power Line Conducted Emission (Conduction 1)

150KHz~30MHz

1.58 dB

2

Power Line Conducted Emission (Conduction 2)

150KHz~30MHz

2.00 dB

3

Disturbance Power Emission (Conduction 1)

30MHz~300MHz

3.12 dB

4

Radiated Emission Test

30MHz~1GHz

3.40 dB

5

Radiated Emission Test

1GHz~18GHz

3.30 dB

Page 7: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 7 of 36

3 Test Facility

Hang Zhou ZJU Interlogic Co., Ltd No. 4004, 14th Floor,XuSheng Building,Bao'an Road, Bao'an District, Shenzhen,Guangdong,China.

3.1 Deviation from standard

None

3.2 Abnormalities from standard conditions

None

4 General Information

4.1 General Description of EUT

Manufacturer: GUANGZHOU OPTONICA LED CO., LTD

Manufacturer Address:

19 QIAODA RD PINGYI INDUSTRY CENTER SHIBI STR PANYU DISTR GUANGZHOU, CHINA.

EUT Name:

LED lights strips

Brand Name:

OPTONICA

Test Model No:

5050-RGBW-60LED-12V-24V

Serial No:

5050-RGBW-96LED/120LED-24V , 5050-RGB-60LED/30LED/120LED-12V,

5050-W-60LED/30LED/120LED-12V, 5050-R-60LED/30LED/120LED-12V,

5050-G-60LED/30LED/120LED-12V, 5050-B-60LED/30LED/120LED-12V,

5050-WW-60LED/30LED/120LED-12V, 5050-Pink-60LED/30LED/120LED-12V,

5050-P-60LED/30LED/120LED-12V,

3528-RGB-60LED/120LED/240LED-12V-24V,

3528-W-60LED/120LED/240LED-12V-24V,

3528-WW-60LED/120LED/240LED-12V-24V,

3528-R-60LED/120LED/240LED-12V-24V,

3528-G-60LED/120LED/240LED-12V-24V,

3528-B-60LED/120LED/240LED-12V-24V,

3528-Pink-60LED/120LED/240LED-12V-24V,

3528-P-60LED/120LED/240LED-12V-24V, 5730-W-60LED/120LED-12V-24V,

5730-WW-60LED/120LED-12V-24V, 5730-R-60LED/120LED-12V-24V,

5730-G-60LED/120LED-12V-24V, 5730-B-60LED/120LED-12V-24V,

5730-Pink-60LED/120LED-12V-24V, 5730-P-60LED/120LED-12V-24V, 3014 2835 RGBW.

Page 8: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 8 of 36

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Power Supply Range: 12-24VDC 10W

Test Power Supply:

24VDC

4.1.1 EUT Test Mode

Mode 1 Lighting/Running

Page 9: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 9 of 36

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

5 Equipments List for All Test Items

No.

Equipment

Manufacturer

Model No.

S/N

Cal date

1

EMI Test Receiver

R&S

ESCI

100612

2014-7-01

2

EMI Test Receiver

R&S

ESPI

100067

2014-7-01

3

Amplifier

HP

8447D

1937A02415

2014-7-01

4

Single Power Conductor

Module

FCC

FCC-LISN-5-50-

1-01-CISPR25

07118

2014-7-01

5

TRILOG Broadband

Test-Antenna

SCHWARZBECK

VULB9163

9163-387

2014-7-01

6

Horn Antenna

SCHWARZBECK

BBHA9120A

B08000991-0021

2014-7-01

7

High Field Biconical Antenna

ELECTRO-METRICS

EM-6913

169

2014-7-01

8

Log Periodic Antenna

ELECTRO-METRICS

EM-6950

818

2014-7-01

9

Remote Active Vertical Antenna

ELECTRO-METRICS

EM-6892

354

2014-7-01

10

Power Clamp

SCHWARZBECK

MDS-21

3898

2014-7-01

11

Single Power Conductor Module

FCC

FCC-LISN-5-50-

1-01-CISPR25

07254

2014-7-01

12

Teo Line Single Phase Module

SCHWARZBECK

NSLK8128

D-69124

2014-7-01

13

Positioning Controller

C&C

CC-C-1F

MF7802155

2014-7-01

14

`Electrostatic Discharge

Simulator

TESEQ

NSG437

128

2014-7-01

15

Fast Transient Burst Generator

SCHAFFNER

MODULA6150

34587

2014-7-01

16

Fast Transient Noise Simulator

Noiseken

FNS-105AX

31438

2014-7-01

17

Capacitive Coupling Clamp

TESEQ

CDN8014

25115

2014-7-01

18

Color TV Pattern Genenator

PHILIPS

PM5418

TM209966

N/A

19

Power Frequency Magnetic

Field Gene

EVERFINE

EMS61000-8K

608085

2014-7-01

20

Triple-Loop Antenna

EVERFINE

LLA-2

607035

2014-7-01

21

10dB attenuator

SCHWARZBECK

MTAIMP-136

R65.90.0009

2014-7-01

Page 10: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 10 of 36

6 Emission Test Results

6.1 Mains Terminals Disturbance Voltage Measurement

Frequency (MHz)

Class A (dBμV) Class B (dBμV)

Q.P. (Quasi-Peak) A.V. (Average) Q.P. (Quasi-Peak) A.V. (Average)

0.15 ~ 0.50 79 66 66 to 56 56 to 46

0.50 ~ 5.0 73 60 56 46

5.0 ~ 30 73 60 60 50

Detector:

Peak for pre-scan (9kHz Resolution Bandwidth)

Quasi-Peak & Average if maximized peak within 6dB of Average Limit

6.1.1 E.U.T. Operation

Temperature:

23C

Humidity:

55% RH

Atmospheric Pressure:

101

Kpa

Test Mode:

Mode 1

The Worst Mode:

Mode 1

6.1.2 Test Specification 40cm V.C.P.

EUT

80cm Pulse Limiter Test Receiver

H.C.P. LISN

EUT was placed upon a wooden test table 0.8m above the horizontal metal reference plane and 0.4m from

the vertical ground plane, and it was connected to an AMN. The closest distance between the boundary of

the EUT and the surface of the AMN is 0.8m. All peripherals were connected to another AMN, and placed at a

distance of 10cm from each other. A spectrum and receiver was connected to the RF output port of the AMN.

Both average and quasi-peak value were detected.

Page 11: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 11 of 36

6.1.3 Measurement Data

An initial pre-scan was performed on the live and neutral lines.

Quasi-peak or average measurements were performed at the frequency which maximum peak emissions were detected.

Please refer to the attached quasi-peak & average measurement data for reference.

Operating mode: Mode 1

Frequency Factor Meter Reading (dBμV) Emission Level (dBμV) Limits (dBμV) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.1620 11.68 39.16 34.59 50.84 46.07 65.36 54.77 -14.52 -8.70

0.2300 10.95 37.24 32.46 48.19 43.41 62.45 52.45 -14.26 -9.04

0.2900 10.76 34.36 31.23 45.12 41.99 60.52 50.52 -15.40 -8.53

2.1940 10.17 32.04 29.48 42.21 39.65 56.00 46.00 -13.79 -6.35

*3.9220 10.17 40.98 31.52 51.15 41.69 56.00 46.00 -4.85 -4.31

10.3820 1.26 43.71 42.47 44.97 43.73 60.00 50.00 -15.03 -6.27

Remark:

1. All readings are Quasi-Peak and Average values.

2. Factor = Insertion Loss + Cable Loss.

3. ‘*’ means the worst case

Page 12: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 12 of 36

6.2 Radiated Electromagnetic Disturbances Measurement

Frequency Range:

9kHz to 30MHz

Limits of Radiated Emission Measurement

Frequency

2m 3m 4m

dB(μA)

dB(μA)

dB(μA)

9 KHz~ 70 KHz 88 81 75

70 KHz ~ 150 KHz 88 to 58 81 to 51 75 to 45

150 KHz ~ 3 MHz 58 to 22 51 to 15 45 to 9

3 MHz ~ 30 MHz 22 15 to 16 9 to 12

Detector:

Peak for pre-scan

Quasi-Peak if maximum peak within 6dB of limit

6.2.1 E.U.T. Operation

Temperature:

22C

Humidity:

51% RH

Atmospheric Pressure:

101

Kpa

Test Mode:

Mode 1

The Worst Mode:

Mode 1

6.2.2 Test Specification

EUT was placed upon a wooden test table which was placed in the center of the test antenna, and operating

in the mode as mentioned above. A receiver is used to detect the actual value of each frequency which need

to be checked. All three field directions were measured in sequence.

Page 13: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 13 of 36

6.2.3 Measurement Data

An initial pre-scan was performed using the receiver in peak detection mode. The EUT was measured by 3

antenna position and peak emissions from the EUT were detected within 6dB of the class B limit line.

The following quasi-peak measurements were performed on the EUT.

Antenna

Position

Frequency

(MHz)

Cable Loss

(dB)

QP Reading

(dBµA)

QP Level

(dBµA)

Margin

(dB)

Limits

(dBµA)

A1

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

A2

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

A3

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

Note: ‘*’ means the disturbance power level 20dB lower than the relevant limit.

QP Level = QP Reading + Cable Loss

Page 14: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 14 of 36

Page 15: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 15 of 36

Page 16: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 16 of 36

Frequency (MHz)

Class A (10m) Class B (3m)

Quasi-Peak

dB(μV/m)

Quasi-Peak

dB(μV/m)

30 ~ 230 40.0 40.0

230 ~ 300 47.0 47.0

6.3 Radiated Emission Measurement

Limits of Radiated Emission Measurement (Below 1GHz)

Detector:

Peak for pre-scan (120kHz resolution bandwidth) Quasi-Peak if maximum peak within 6dB of limit

6.3.1 E.U.T. Operation

Temperature:

24C

Humidity:

52% RH

Atmospheric Pressure:

101

Kpa

Test Mode:

Mode 1

The Worst Mode:

Mode 1

6.3.2 Test Specification

3 m

1~ 4 m

EUT

80 cm

Test Receiver Amp

EUT was placed upon a wooden test table which was placed on the turn table 0.8m above the horizontal metal

ground plane, and operating in the mode as mentioned above. A receiving antenna was placed 3m away from

the EUT. During testing, turn around the turn table and move the antenna from 1m to 4m to find the maximum

field-strength reading. All peripherals were placed at a distance of 10cm between each other. Both horizontal

and vertical antenna polarities were tested.

Page 17: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 17 of 36

6.3.3 Measurement Data

An initial pre-scan was performed in the 3m chamber using the spectrum analyzers in peak detection mode.

The EUT was measured by Biology antenna with 2 orthogonal polarities and peak emissions from the EUT

were detected within 6dB of the class B limit line.

The following quasi-peak measurements were performed on the EUT.

Horizontal -- Input: DC24V Operating mode: Mode 1

Frequency Factor Meter Reading Emission Level Margin Limits

(MHz) (dB) (dBμV) (dBμV/m) (dB) (dBμV/m)

239.520** 15.160 4.058 19.218 -27.782 47.000

335.550** 18.150 2.467 20.617 -26.383 47.000

363.680** 18.820 2.268 21.088 -25.912 47.000

431.580** 20.750 6.469 27.219 -19.781 47.000

527.610** 22.810 3.906 26.716 -20.284 47.000

748.770** 27.960 2.558 30.518 -16.482 47.000

Remark:

1. “ * ” Mark means readings are Peak Values.

2. “ ** “ Mark means readings are Quasi-Peak values.

3. Factor = Antenna Factor + Cable Loss – Pre-amplifier.

Page 18: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 18 of 36

VERTICAL -- Input: DC24V Operating mode: Mode 1

Frequency Factor Meter Reading Emission Level Margin Limits

(MHz) (dB) (dBμV) (dBμV/m) (dB) (dBμV/m)

335.550** 18.150 1.896 20.046 -26.954 47.000

363.680** 18.820 3.120 21.940 -25.060 47.000

431.580** 20.750 6.524 27.274 -19.726 47.000

527.610** 22.810 2.984 25.794 -21.206 47.000

748.770** 27.960 2.495 30.455 -16.545 47.000

978.660** 30.300 6.183 36.483 -10.517 47.000

Remark:

1. “ * ” Mark means readings are Peak Values.

2. “ ** “ Mark means readings are Quasi-Peak values.

3. Factor = Antenna Factor + Cable Loss – Pre-amplifier.

Page 19: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 19 of 36

6.4 Harmonics

Frequency Range:

100Hz to 2kHz

Test Requirement:

EN 61000-3-2

6.4.1 E.U.T. Operation

Temperature:

22C

Humidity:

50% RH

Atmospheric Pressure:

101

Kpa

Test Mode:

Mode 1

The Worst Mode:

Mode 1

6.4.2 Test specification

EUT operated in the mode as mentioned above, and connected to Harmonic/Flicker measuring equipment

which was connected to an AC power source. Measurement was performed after EUT operating in static

state for 10 seconds. Each order harmonics found to meet the relevant limits.

Page 20: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 20 of 36

6.4.3 Measurement Data PASS

6.5 Voltage changes, voltage fluctuations and flicker

Test Requirement:

EN 61000-3-3

6.5.1 E.U.T. Operation

Temperature:

22C

Humidity:

50% RH

Atmospheric Pressure:

101

Kpa

Test Mode:

Mode 1

The Worst Mode:

Mode 1

6.5.2 Test specification

EUT was operated in the mode as mentioned above, and connected to Harmonic/Flicker measuring

equipment which was connected to an AC power source.

6.5.3 Measurement Data

PASS

Page 21: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 21 of 36

7 Immunity Test Results

7.1 Electrostatic discharge immunity test

Acceptable

Performance Criterion:

B

Discharge Impedance:

330 / 150 pF

Discharge Voltage:

Air Discharge: ±8 kV

Contact Discharge: ±4 kV

VCP, HCP: ±4 kV

Polarity:

Positive & Negative

Minimum discharge Interval:

1 second

7.1.1 E.U.T. Operation

Temperature:

24C

Humidity:

48% RH

Atmospheric Pressure:

101

Kpa

Test Mode:

Mode 1

The Worst Mode:

Mode 1

Page 22: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 22 of 36

7.1.2 Test specification

EUT was operated in the mode as mentioned above. Both contact and air discharge was executed. Contact

discharge to the conductive surfaces and to coupling planes; air discharge at insulating surfaces. Each test

point shall be subjected to 10 discharges at least (For each voltage and polarity).

7.1.3 Measurement Data

Form:AMC 410-6

Test Record

Electrostatic Discharge Test Results

Applicant : GUANGZHOU OPTONICA

LED CO., LTD

EUT:LED lights strips

M/N:5050-RGBW-60LED-12V-24V

Test Voltage:Input: DC24V

Test Date:Sep. 21, 2014

IEC61000-4-2

EN61000-4-2

other:

Test Result: Pass Fail

Temp: 24 C Humi: 48

% Atmospheric Pressure:

101 Kpa

Operating Mode

1

Discharge times

Contact discharge: minimum 10 times (+/-respectively) at each point,

Air discharge: minimum 10 times (+/- respectively) at each point.

Discharge Mode

Air Discharge

Contact Discharge

Performance

Criterion

Result

Page 23: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 23 of 36

Test level (kV) 4 8 10 15 2 4 6 8

Test Location + - + - + - + - + - + - + - + -

HCP

A

A

B

Pass

VCP

A

A

Pass

A1

B

B

Pass

A2

B

B

Pass

Note: “P” means Pass , Horizontal Coupling Plane(HCP) and Vertical Coupling plane(VCP).

7.2 RF field strength immunity test

Acceptable

Performance Criterion:

A

Test Level

3 V/m

Test Distance

3 m

Frequency Range

80MHz~1000MHz

Polarity:

Horizontal & Vertical

7.2.1 E.U.T. Operation

Temperature:

24C

Humidity:

52% RH

Atmospheric Pressure:

101

Kpa

Test Mode:

Mode 1

The Worst Mode:

Mode 1

Page 24: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 24 of 36

7.2.2 Test specification

Test was executed in a fully Anechoic chamber. An antenna was used to transmit interference signal. EUT

was placed upon a wooden table above the reference ground 0.8m, and was positioned so that the four sides

of the EUT shall be exposed to the electromagnetic field in a sequence. In each position the performance of

the EUT was investigated. A camera was used to monitor the loss of function or degradation of performance

of the EUT.

Page 25: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 25 of 36

7.2.3 Measurement Data

Form:AMC410-7

Test Record

Radiated Frequency Field Strength Susceptibility Results

Applicant : GUANGZHOU OPTONICA

LED CO., LTD

EUT:LED lights strips

M/N:5050-RGBW-60LED-12V-24V

Test Voltage:Input: DC24V

Test Date:Sep. 21, 2014

IEC61000-4-3

EN61000-4-3

other:

Test Result: Pass Fail

Temp: 24 C Humi: 52 %

Atmospheric Pressure: 101 Kpa

Test Port Enclosure

Operating

Mode

Mode 1

Test Level

3 V/m(r.m.s) ( unmodulated )

Criteri

on

Frequency Range(MHZ)

Antenna polarity

Modulation

EUT

positio

n

Result

80~1000

Horizontal

1KHz,

80% AM

Front

Pass

Rear

Pass

Left

Pass

Right

Pass

80~1000

Vertical

1KHz,

80% AM

Front

Pass

Rear

Pass

Left

Pass

Right

Pass

Page 26: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 26 of 36

7.3 Electrical fast transient/burst immunity test

Acceptable

Performance Criterion:

B

Test Level:

0.5, 1.0, kV on AC Line; 0.5 kV on Signal Line

Repetition Frequency:

5 kHz

Burst Duration:

300 ms

Test Duration:

1 minutes for each level & polarity

7.3.1 E.U.T. Operation

Temperature:

24C

Humidity:

48% RH

Atmospheric Pressure:

101

Kpa

Test Mode:

Mode 1

The Worst Mode:

Mode 1

7.3.2 Test specification

EUT was placed on a metal ground reference plane and was insulated from it by a wooden support which is

0.1m thick. The ground reference plane is connected to the protective earth. The test generator and the

coupling/decoupling network were placed directly on, and bonded to the ground reference plane.

Page 27: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 27 of 36

7.3.3 Measurement Data

Form:AMC 410-8

Test Record

Electrical Fast Transient/Burst Result

Applicant : GUANGZHOU OPTONICA

LED CO., LTD

EUT:LED lights strips

M/N:5050-RGBW-60LED-12V-24V

Test Voltage:Input: DC24V

Test Date:Sep. 21, 2014

IEC61000-4-4

EN61000-4-4

other:

Test Result: Pass Fail

Temp: 24 C Humi: 48 %

Atmospheric Pressure: 101 Kpa

Test Signal

Rise time: 5ns, Duration: 50ns, repetition rate : 5KHz 100KHz

Coupling Line

Test level (kV)

Performance

Criterion

Resul

t 0.5 1 2 4

+ - + - + - + -

A

C

lin

e

L

A

A

B

Pass

N A A Pass

PE

L+N A A Pass

L+PE

N+PE

L+N+PE

DC Line

Signal Line

Note:

Page 28: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 28 of 36

7.4 Surge immunity test

Acceptable

Performance Criterion:

B

Test Level:

0.5, 1kV Line to Neutral

0.5, 1, 2kV Line, Neutral to Earth

Polarity:

Positive & Negative

Generator source impedance:

2 Ω & 12 Ω

Trigger Mode:

Internal

No. of surges:

5 positive & 5 negative at 0, 90, 180, 270.

7.4.1 E.U.T. Operation

Temperature:

23C

Humidity:

51% RH

Atmospheric Pressure:

101

Kpa

Test Mode:

Mode 1

The Worst Mode:

Mode 1

7.4.2 Test specification

EUT was placed on a wooden table which is 0.8m above the ground and operated in the mode as mentioned

above. The power cord between the EUT and the coupling/decoupling network was bundled so as to make it

less than 2 m in length.

Page 29: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 29 of 36

7.4.3 Measurement Data

Form:AMC 410-9

Test Record

Surge Immunity Test Result

Applicant : GUANGZHOU OPTONICA

LED CO., LTD

EUT:LED lights strips

M/N:5050-RGBW-60LED-12V-24V

Test Voltage:Input: DC24V

Test Date:Sep. 21, 2014

IEC61000-4-5

EN61000-4-5

other:

Test Result: Pass Fail

Temp: 24 C Humi: 50 %

Atmospheric Pressure: 101 Kpa

Test Signal

1.2/50 μs 10/700μs

Interval: 120 seconds Pluse: 5 times

Coupling Line

Test level Performance

Criterion

Result 0.5 kV 1 kV 2 kV 4 kV

+ - + - + - + -

A

C

li

n

e

L-N

B

90° A PASS

180°

270° A PASS

L-PE

90°

180°

270°

N-PE

90°

180°

270°

DC Line

Signal Line

Note:

Page 30: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 30 of 36

7.5 Conducted disturbance immunity Test

Acceptable

Performance Criterion:

A

Test Level

3 V

Frequency Range

0.150MHz~80MHz

7.5.1 E.U.T. Operation

Temperature:

24C

Humidity:

50% RH

Atmospheric Pressure:

101

Kpa

Test Mode:

Mode 1

The Worst Mode:

Mode 1

7.5.2 Test specification

The equipment to be tested was placed on an insulating support of 0,1m height above a ground reference

Plane. The minimum distance between the EUT and all other conductive structures, except the ground

reference plane is more than 0.5m. All relevant cables were provided with the appropriate coupling and

decoupling devices at a distance between 0.1m and 0.3m from the projected geometry of the EUT.

Page 31: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 31 of 36

7.5.3 Measurement Data

Form:AMC 410-10

Test Record

Injected Currents Susceptibility Measurement Result

Applicant : GUANGZHOU OPTONICA

LED CO., LTD

EUT:LED lights strips

M/N:5050-RGBW-60LED-12V-24V

Test Voltage:Input: DC24V

Test Date:Sep. 21, 2014

IEC61000-4-6

EN61000-4-6

other:

Test Result: Pass Fail

Temp: 24 C Humi: 50 %

Atmospheric Pressure: 101 Kpa

Test Port

AC Port

Operating

Mode

Mode 1

Test

Leve

l (V)

3 V(r.m.f) ( unmodulated )

Criterion

A

Step Size 1 % Dwell Time(S)

1

Frequency Range

(MHz)

Modulation

Result

0.15~80

1 KHz,

80 % AM

Pass

KHz,

% AM

Note:

Page 32: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 32 of 36

7.6 Power frequency magnetic field immunity test

Acceptable

Performance Criterion:

A

Test Level:

1 A/m

Coil Orientation:

X & Y & Z

Test Duration:

5 Minutes for each orientation

7.6.1 E.U.T. Operation

Temperature:

20C

Humidity:

52% RH

Atmospheric Pressure:

101

Kpa

Test Mode:

Mode 1

The Worst Mode:

Mode 1

7.6.2 Test specification

The equipment is configured and connected to satisfy its functional requirements. It was placed on the ground

reference plane with the interposition of a 0.1 m thickness wooden support and was placed in the center of the

induction coil. All cables (include power cord and signal line) were exposed to the magnetic field for at least

1m of their length.

Page 33: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 33 of 36

7.6.3 Measurement Data

Form:AMC 410-14

Test Record

Power Frequency Magnetic Field Immunity Test Results

Applicant : GUANGZHOU OPTONICA

LED CO., LTD

EUT:LED lights strips

M/N:5050-RGBW-60LED-12V-24V

Test Voltage:Input: DC24V

Test Date:Sep. 21, 2014

IEC61000-4-8

EN61000-4-8

other:

Test Result: Pass Fail

Temp: 24 C Humi: 50 %

Atmospheric Pressure: 101 Kpa

Operating

Mode

Mode 1

Test Level

Test Duration

Coil Orientation

Criterion

Result

1 A/m

5 minus

X

A

Pass

1 A/m

5 minus

Y

A

Pass

1 A/m

5 minus

Z

A

Pass

Note:

Page 34: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 34 of 36

7.7 Voltage dips and interruptions immunity test

Acceptable

Performance Criterion:

B & C

Test Level:

<5% of UT (Supply Voltage) for 0.5 and 250 Periods

70 % of UT (Supply Voltage) for 25 Periods

No. of Dips / Interruptions:

3 per Level

7.7.1 E.U.T. Operation

Temperature:

22C

Humidity:

47% RH

Atmospheric Pressure:

101

Kpa

Test Mode:

Mode 1/ Mode 2/ Mode 3/ Mode 4

The Worst Mode:

Mode 1

7.7.2 Test specification

EUT connected to the test generator with the shortest power supply cable as specified by the EUT

manufacturer. The rated voltage of the EUT was used as the basis for voltage test level specification. After

each group of tests, a full functional check was performed.

Page 35: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 35 of 36

7.7.3 Measurement Data

Form:AMC 410-11

Test Record

Voltage Dips And Interruptions Test Result

Applicant : GUANGZHOU OPTONICA

LED CO., LTD

EUT:LED lights strips

M/N:5050-RGBW-60LED-12V-24V

Test Voltage:Input: DC24V

Test Date:Sep. 21, 2014

IEC61000-4-11

EN61000-4-11

other:

Test Result: Pass Fail

Temp: 24 C Humi: 50 %

Atmospheric Pressure: 101 Kpa

Test Port

AC Port

Operating

Mode

Mode 1

Level

(%UT)

Interruption &

Dips(%UT)

Duration

(Cyc)

Phase

Criterion

Result

70 30 10 90 C PASS

0 100 0.5 180 B PASS

Note:None

Page 36: EMC Test Report - Optonica LED€¦ · EMC-Report No.: SZZCT1409240B-EMC-01 Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an

Shenzhen ZCT Technology Co., Ltd. EMC-Report No.: SZZCT1409240B-EMC-01

Shenzhen ZCT Technology Co., Ltd. 3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China.

Tel: 400-805-1899 Fax: 86-755-23702323; http: //www.renzhengjiance.com

Page 36 of 36

8 APPENDIX-Photographs of EUT Constructional Details