Pre-insulated terminalsElpress ring, fork and pin terminals are manufactured from high grade copper and receptacles from brass or tin-bronze. All terminals are electrolytically tin plated to achieve good corrosion protection. The necks of the terminals are brazed and annealed to allow crimping in any direction around the neck. The metal in the receptacles neck is double folded for excellent mechanical strength and electrical conductivity.

Marking of the preinsulated terminalsElpress pre-insulated terminals are, if possible, marked with logotype, nominal max cross section area (mm) and possible metric stud hole size. This simplifies the identification and inspection. When crimping with Elpress tools an imprint is made on the insulation to show that the proper die nest has been used. Elpress ESA tools also leave a logo imprint to indicate Elpress system crimps, traceable to adequate test standards.

Example of product designation Cat. no. A1532R (E, FLS, G etc) A = pre-insulated 15 = cross section area (1,5 mm) 32 = characteristic size (stud hole 3,2 mm) E =end connectors FLS = receptacles, rolled type FLSF = receptacles, fully insulated rolled type FLSH = multiple tabs, rolled type (piggy back) FLST = receptacles, rolled type, tin-bronze G = fork terminals GB = flanged fork terminals H = tabs (male) HA = bullets (male) HO = sockets (female) K = hook terminals PSK = parallel connectors R = ring terminals SF = blade terminals SFB = blade terminals (flanged) SFK = blade terminals SFL = blade terminals SFN =blade terminals (with tab) SR = pin terminals SRK = pin terminals SK = through connectors SKW = through connectors with heat shrink insulation

InsulationElpress insulation sleeves are moulded in polycarbonate which has excellent deformation characteristics and maintains its vibration support up to high temperatures, well over 100 C. Caution must be taken at alkalic exposure. The colour of the insulation sleeve relates to which cross section area the terminal accepts:Light yellow sleeve Green sleeve* Red sleeve Blue sleeve Yellow sleeve* or transparent white

0,1 - 0,5 mm 0,25 - 0,75 mm 0,5 - 1,5 mm 1,5 - 2,5 mm 4 - 6 mm

EasyEntryMost Elpress insulation sleeves are of EasyEntry type which guides all the conductor strands properly into the terminal neck. The risk for back-folded strands, possibly resulting in flash-overs and reduced crimped cross section area is therefore minimised.

Samples of Elpress crimped pre-insulated terminals.

EasyEntry.

1:2www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Pre-insulated terminals 0.1 - 6 mm

Ring terminals 0.1 - 6 mmData: Cu 99.95%, tin plated, brazed necks, PC sleeves have EasyEntry, PC and PA sleeves are halogen free.mm 0,10,5 Cat. no. A0527R A0532R A0543R A0553R A0832R A0837R A0843R A0853R A1532R A1537R A1543R A1553R A1565R A1585R A1510R A2532R A2537R A2543R A2553R A2565R A2585R A2510R A2513R A4643R A4653R A4665R A4685R A4610R A4613R Screw M2,5 M3 M4 M5 M3 M3,5 M4 M5 M3 M3,5 M4 M5 M6 M8 M10 M3 M3,5 M4 M5 M6 M8 M10 M12 M4 M5 M6 M8 M10 M12 mm W 5,4 5,4 7,0 8,0 5,5 6,2 7,5 9 5,5 6,2 7,5 9,0 11,0 14,0 17,0 5,5 6,2 7,5 9,0 11,0 14,0 17,0 19,0 7,8 9,0 11,0 14,0 17,0 19,2 d 2,0 2,0 2,0 2,0 3,2 3,2 3,2 3,2 4,0 4,0 4,0 4,0 4,0 4,0 4,0 t 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,7 0,7 0,7 0,7 0,7 0,7 0,7 L1 14,0 16,0 16,0 15,0 15,0 17,5 17,5 17,5 15,0 17,5 17,5 17,5 19,5 21 23 15,0 17,5 17,5 17,5 19,5 21 23 25 21 21 22 23 25 31 L 16,0 16,0 19,0 19,0 18,0 21 21 22 18,0 21 21 22 25 28 31 18,0 21 21 22 25 28 31 34 25 25 27 30 33 40 s 6 6 6 6 7 7 7 7 7 7 7 7 7 7 7 8 8 8 8 8 8 8 8 9 9 9 9 9 9 8:3, 8:6 8:3-6 8:16-18 Crimp tools page 8:4 8:16-17 Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 50 50 Insulation PA* PA* PA* PA* PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PVC* PC PC PC PC PC PVC*

1

0,250,75

0,51,5

1,52,5

4,5 0,8 4,5 0,8 4,5 0,8 4,5 0,8 4,5 0,8 4,5 0,8 4,5 0,75 4,5 0,75 6,4 6,4 6,4 6,4 6,4 6,8 1,0 1,0 1,0 1,0 1,0 1,0

46

t = palm thickness s = strip length * no EasyEntry

Certificate FM20987 ISO 9001:2000

1:3www.sourceiec.com

Pre-insulated terminals 0.1 - 6 mm

1

Fork terminals 0.1 - 6 mmData: Cu 99.95%, tin plated, brazed necks, PC sleeves have EasyEntry, insulation sleeves are halogen free.mm 0,1-0,5 0,250,75 0,51,5 Cat. no. A0532G A0832G A0837G A0843G A1532G A1537G A1537GS A1543G A1553G A1565G A2532G A2537G A2537GS A2543G A2553G A2565G A4643G A4653G A4665G A4685G A4610G Screw M3 M3 M3,5 M4 M3 M3,5 M3,5 M4 M5 M6 M3 M3,5 M3,5 M4 M5 M6 M4 M5 M6 M8 M10 mm W 5,0 5,5 6,2 7,5 5,5 6,2 5,5 7,0 9,0 11,0 5,5 6,2 5,5 7,0 9,0 11,0 7,8 9,0 11,0 14,0 18,0 d t L1 L 16,0 18,0 21 21 18,0 21 21 21 22 25 18,0 21 21 21 22 25 25 25 27 30 36 s 6 7 7 7 7 7 7 7 7 7 8 8 8 8 8 8 9 9 9 9 9 8:3, 8:6 8:3-6 8:16-18 Crimp tools page 8:4, 8:16-17 Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 Insulation PA* PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC

2,0 0,5 14,0 3,2 0,5 15,0 3,2 0,5 17,5 3,2 0,5 17,5 4,0 4,0 4,0 4,0 4,0 4,0 4,5 4,5 4,5 4,5 4,5 4,5 6,4 6,4 6,4 6,4 6,4 0,7 0,7 0,7 0,7 0,7 0,7 0,8 0,8 0,8 0,8 0,8 0,8 1,0 1,0 1,0 1,0 1,0 15,0 17,5 17,5 17,5 17,5 19,5 15,0 17,5 17,5 17,5 17,5 19,5 21 21 22 23 27

1,52,5

4-6

t = palm thickness s = strip length * no EasyEntry

Flanged fork terminals 0.5 - 2.5 mmData: Cu 99.95%, tin plated, brazed necks, PC sleeves have EasyEntry, insulation sleeves are halogen free.mm 0,51,5 1,52,5 Cat. no. A1537GB A1543GB A2543GB A2553GB Screw M3,5 M4 M4 M5 mm W 7,5 7,5 7,5 9,0 d 4,0 4,0 4,5 4,5 t 0,7 0,7 0,8 0,8 L1 L s Crimp tools page 8:3-6 8:16-18 Pcs/ pack 100 100 100 100 Insulation PC PC PC PC

17,5 21 7 17,5 21 7 17,5 21 7 17,5 23 7

t = palm thickness s = strip length

Hook terminals 0.5 - 2.5 mmData: Cu 99.95%, tin plated, brazed necks, PC sleeves have EasyEntry, insulation sleeves are halogen free.mm 0,5-1,5 1,5-2,5 Cat. no. A1543K A2543K Screw M4 M4 mm W 7,5 7,5 d t L1 L s Crimp tools page 8:3-6, 8:16-18 8:3-6, 8:16-18 Pcs/ pack 100 100 Insulation PC PC

4,0 0,8 4,5 0,8

17,5 21 7 17,5 21 8

t = palm thickness s = strip length

1:4www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Pre-insulated terminals 0.1 - 6 mm

Pin terminals 0.1 - 6 mmData: Cu 99.95%, tin plated, brazed necks, PC sleeves have EasyEntry, insulation sleeves are halogen free.mm 0,1-0,5 0,25-0,75 0,5-1,5 1,5-2,5 4-6 Cat. no. A0514SR A0819SR A0819SRK A1519SR A1519SRK A2519SR A2519SRK A4630SR mm W 1,4 1,8 1,8 1,9 1,9 1,9 1,9 2,8 d 2,0 3,2 3,2 4,0 4,0 4,5 4,5 6,4 L1 8,0 12,0 8,5 12,0 8,5 12,0 8,5 17,0 L 18,0 22 18,5 22 18,5 22 18,5 27 s 6 7 7 7 7 8 8 9 Pcs/ pack 100 100 100 100 100 100 100 100 8:3, 8:6 8:3-6 8:16-18 Crimp tools page 8:4, 8:16-17 Insulation PA* PC PC PC PC PC PC PC

1

s = strip length * no EasyEntry

Blade terminals 0.25 - 6 mmData: Cu 99.95%, tin plated, brazed necks, PC sleeves have EasyEntry, PC and PA sleeves are halogen free.mm 0,25-0,75 0,5-1,5 Cat. no. A0825SFK A1518SFL A1529SF A1529SFN A1530SFB A2524SFL A2529SF A2529SFN A2530SFB A4640SF A4645SFB mm W 2,5 2,3 2,9 2,9 3,0 2,4 2,9 2,9 3 4 4,5 d 3,2 4,6 4,0 4,5 4,5 4,5 4,3 4,5 4,6 6,7 6,7 t 0,5 0,8 0,7 0,7 0,8 0,8 0,7 0,7 0,7 1,0 1,0 L1 10,0 18,0 12,0 11,5 17,5 18,0 11,5 11,5 17,5 13,0 17,5 L 20 27 22 22 27 28 22 22 27 27 32 s 7 7 7 7 7 8 8 8 8 9 9 Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 8:3, 8:6 Crimp tools page 8:4, 8:16-17 8:3-6 8:16-18 Insulation PC PA PC PC** PA PA** PC PC** PA* PVC* PVC*

1,5-2,5

4-6

t = palm thickness s = strip length * no EasyEntry ** with tab

Through connectors 0.25 - 6 mmData: Cu 99.95%, tin plated, insulation sleeves are halogen free, no EasyEntry.mm 0,25-0,75 0,5-1,5 1,5-2,5 4-6s = strip length

Cat. no. A0824SK A1525SK A2527SK A4652SK

mm d 2,9 3,4 4,3 6,5

L 24 24 26 33

s 7 7 8 9

Pcs/ pack 100 100 100 50 8:3-6

Crimp tools page 8:4, 8:16-17 8:3-6, 8:3-6, 8:6 8:16-18

Insulation PC PC PC PC

Certificate FM20987 ISO 9001:2000

1:5www.sourceiec.com

Pre-insulated terminals 0.1 - 6 mm

1

Through connectors with heat shrink insulation 0.5 - 6 mmData: Cu 99.95%, tin plated, heat shrink sleeve with melting glue inside.mm 0,5-1,5 1,5-2,5 4-6s = strip length After crimping and hot air gun heating, a water proof connection, glued to the cable and the connector, is achieved.

Cat. no. A1535SKW A2535SKW A4650SKW

mm d 4,5 5,4 6,8

L 35 35 40

s 8 8 9

Pcs/ pack 25 25 25

Crimp tools page 8:5

Insulation PA PA PA

Parallel connectors 0.5 - 6 mmData: Cu 99.95%, tin plated.mm Total 0,5-1,5 1,5-2,5 4-6s = strip length Type PSK must be crimped with ESA0760 (C) and with two crimps.

Cat. no. A1515PSK A2517PSK A4634PSK

mm d 3,2 4 5,6

L 17,0 17,0 21

s 7 8 9

Pcs/ pack 100 100 100

Crimp tools page 8:3-6, 8:3-6 8:3, 8:6 8:16-18

Insulation PVC PVC PVC

Receptacles 0.1 - 6 mmData: brass or tin bronze, tin plated, brazed necks, PC sleeves have EasyEntry, PC and PA insulation sleeves are halogen free.mm 0,1-0,5 0,5-1,5 Cat. no. A0503FLS5 A0503FLS8 A1503FLS5 A1503FLS8 A1505FLS5 A1505FLS8 A1507FLS A1507FLST A2505FLS5 A2505FLS8 A2507FLS A2507FLST A2508FLS A4607FLS A4609FLS mm d 2,3 2,3 3,3 3,3 3,7 3,7 4,0 4,0 4,4 4,4 4,5 4,5 4,3 6,4 6,2 L 16,0 16,0 18,5 18,5 19,0 19,0 20 20 19,0 19,0 20 20 24 24 31 For tabs 2,8x0,5 2,8x0,8 2,8x0,5 2,8x0,8 4,8x0,5 4,8x0,8 6,3x0,8 6,3x0,8 4,8x0,5 4,8x0,8 6,3x0,8 6,3x0,8 8,4x0,8 6,3x0,8 9,5x1,2 s 7 7 7 7 7 7 7 7 8 8 8 8 8 9 9 Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 8:3, 8:6 Crimp tools page 8:4, 8:4 8:3-6 8:16-18 8:16-17 Insulation PVC* PVC* PC PC PC PC PC PC** PC PC PC PC** PVC*** PC PVC***

1,5-2,5

4-6

s = strip length * no EasyEntry ** made from tin-bronze (phosphorus bronze) *** not brazed, reinforcement sleeve, no EasyEntry.

1:6www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Pre-insulated terminals 0.1 - 6 mm

Multiple tabs 0.5 - 2.5 mmData: brass, tin plated, no EasyEntry.mm 0,5-1,5 1,5-2,5 Cat. no. A1507FLSH A2507FLSH mm d 3,7 4,3 L 22 22 For tabs 6,3x0,8 6,3x0,8 s 7 8 Pcs/ pack 100 100 Crimp tools page 8:3-6,8:16-18 8:3-6,8:16-18 Insulation PVC* PVC*

1

s = strip length * non-brazed with reinforcement sleeve

Receptacles, fully insulated 0.5 - 6 mmData: brass, tin plated, brazed necks, PC sleeves have EasyEntry, insulation sleeves are halogen free.mm 0,5-1,5 Cat. no. A1503FLSF5 A1503FLSF8 A1505FLSF5 A1505FLSF8 A1507FLSF A2505FLSF5 A2505FLSF8 A2507FLSF A4607FLSF mm d 3,8 3,8 3,6 3,6 4,0 3,9 3,9 4,5 5,3 L 19,3 19,3 20,2 20,2 21 19,5 19,5 21 26 For tab 2,8x0,5 2,8x0,8 4,8x0,5 4,8x0,8 6,3x0,8 4,8x0,5 4,8x0,8 6,3x0,8 6,3x0,8 s 7 7 7 7 7 8 8 8 9 Pcs/ pack 100 100 100 100 100 100 100 100 100 8:3, 8:6 Crimp tools page 8:3-6 8:16-18 Insulation PA* PA* PA* PA* PC PA* PA* PC PA*

1,5-2,5

4-6s = strip length

* non-brazed with reinforcement sleeve, no EasyEntry

Tabs 0.5 - 6 mmData: brass, tin plated, brazed necks, PC sleeves has EasyEntry, PC insulation sleeves are halogen free.mm d 4,0 4,5 6,3 For receptacles 6,3x0,8 6,3x0,8 6,3x0,8 Pcs/ pack 100 100 100 Crimp tools page 8:3-6, 8:16-18 Insulation PC PC PVC*

mm 0,5-1,5 1,5-2,5 4-6s = strip length

Cat.no. A1507H A2507H A4607H

L 22 22 25

s 7 8 9

* non-brazed with reinforcement sleeve, no EasyEntry.

Certificate FM20987 ISO 9001:2000

1:7www.sourceiec.com

Pre-insulated terminals 0.1 - 6 mm

1mm 1-3 4-6s = strip length

End connectors, fully insulated, 1 - 6 mmData: Copper tube, tin plated, insulation sleeves are halogen free.Cat. no. A2500E A4600E mm d 6,4 9,2 L1 8,0 9,0 L 15,2 17,7 s 8 9 Pcs/ pack 100 100 Crimp tools page 8:3-6, 8:16-18 8:3-6, 8:16-18 Insulation PA PA

Bullets 0.25 - 6 mmData: brass/Cu, tin plated, PC sleeves have EasyEntry, PC and PA insulation sleeves are halogen free.mm 0,25-0,75 0,5-1,5 1,5-2,5 4-6 Cat. no. A0802HA A1504HA A2505HA A4605HA mm d 3,6 4,0 4,3 6,5 L 26 22 20 21 Diameter 2,0 4,0 5,0 5,0 s 7 7 8 9 Pcs/ pack 100 100 100 100 Crimp tools page 8:4, 8:16-17 8:3-6, 8:16-18 Insulation PA* PC PVC* PVC*

s = strip length * non-brazed with reinforcement sleeve, no EasyEntry.

Sockets, fully insulated 0.25 - 6 mmData: brass/tin bronze/Cu, tin plated, PC sleeves have EasyEntry, PC and PA insulation sleeves are halogen free.mm 0,25-0,75 0,5-1,5 1,5-2,5 4-6 Cat. no. A0802HO A1504HO A2505HO A4605HO mm d 3,4 4,0 4,3 6,5 L 24 25 26 23 For bullets diam. 2,0 4,0 5,0 5,0 s 7 7 8 9 Pcs/ pack 100 100 100 100 Crimp tools page 8:4, 8:16-17 8:3-6, 8:16-18 Insulation PA* PC** PVC* PVC*

s = strip length * non-brazed with reinforcement sleeve ** made from tin bronze (phosphorous bronze), EasyEntry

1:8www.sourceiec.com

Certificate FM20987 ISO 9001:2000

End terminals (ferrules) 0.14 - 50 (185) mm

End terminalsElpress pre-insulated and un-insulated end terminals are manufactured from tin plated, electrolytic 99.95% copper tubes. The end terminals have dimensions in accordance with DIN 46228 (with a few exceptions, see tables). The pre-insulated sleeves are made of PP, polypropylene, and have a conical EasyEntry, inside shape. Elpress end terminals are used when a perfect connection is required, for example, to a screw terminal block. The strands are kept together and connecting screws will not damage the strands. Long lasting contact forces are easier to achieve. When using the appropriate Elpress ratchet crimp tools a connection with approval to VDE 0609 is achieved. In addition to the pre-insulated end terminals shown in the tables, we also offer similar terminals with other commonly used colour codings systems as well as terminals above 50 mm when needed.Cross section area mm 0,14 0,25 0,34 0,50 0,75 1 1,5 2,5 4 6 10 16 25 35 50

Colour codesColours as per DIN 46228 T4 Elpress typ ET2 TWIN grey yellow turqoise white grey red black blue grey yellow red blue yellow red blue Elpress Standard colour W type ET grey light blue turquoise red-orange white yellow red blue grey black ivory green brown beige

2

Alternative colour T brown violet pink white blue red black grey orange green brown white black

Crimped pre-insulated end terminal.

Crimped TWIN end terminal.

Product designationsCat. no. A4-12ET (example) A = pre-insulated B = un-insulated 4 = cross section area (4 mm) 12 = metal sleeve length ET = end terminal ET2 = TWIN end terminal

2:2www.sourceiec.com

Certificate FM20987 ISO 9001:2000

End terminals (ferrules) 0.14 - 50 (185) mm

Pre-insulated end terminals 0.14 - 35 mmData: Cu 99.95%, tin plated, polypropylene insulation, dimensions according to DIN 46228, colour code W.mm 0,14 0,25 0,5 Cat. no. A0,14-6ET A0,25-6ET A0,5-6ET A0,5-8ET A0,5-10ET A0,75-6ET A0,75-8ET A0,75-10ET A0,75-12ET A1-6ET A1-8ET A1-10ET A1-12ET A1,5-8ET A1,5-10ET A1,5-18ET A2,5-8ET A2,5-12ET A2,5-18ET A4-10ET A4-12ET A4-18ET A6-12ET A6-18ET A10-12ET A10-18ET A16-12ET A16-18ET A25-16ET A25-22ET A35-16ET A35-25ET mm d 2,0 2,0 2,5 2,5 2,5 2,8 2,8 2,8 2,8 3,0 3,0 3,0 3,0 3,4 3,4 3,4 4,2 4,2 4,2 4,8 4,8 4,8 6,2 6,2 7,5 7,5 8,8 8,8 11,0 11,0 12,5 12,5 L1 6 6 6 8 10 6 8 10 12 6 8 10 12 8 10 18 8 12 18 10 12 18 12 18 12 18 12 18 16 22 16 25 L 10,5 10,5 11,5 13,5 15,5 12,0 14,0 16,0 18,0 12,5 14,5 16,5 18,5 14,5 16,5 24,5 15,0 19,0 25,0 18,0 20,0 26,0 20 26 21 27 23 29 29 35 30 39 s 8 8 8 10 12 8 10 12 14 8 10 12 14 10 12 20 10 14 20 12 14 20 14 20 14 20 14 20 18 24 18 27 8:11-18 Crimp tools page 8:13 8:5, 8:11-13, 8:16-17 8:5, 8:11-18 Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50

2

0,75

1

1,5

2,5

4

6 10 16 25 35s = strip length

For other colour codes and for larger areas than 35 mm, contact Elpress.

Pre-insulated end terminals for short-circuit proof cable-insulations 1.5 - 16 mmData: Cu 99.95%, tin plated, polypropylene insulation, dimensions according to DIN 46228 (not insulation), colour code DIN.mm 1,5 1,5 2,5 2,5 4 6 10 16 Cat. no. A1,5-8ETDXL A1,5-10ETDXL A2,5-8ETDXL A2,5-12ETDXL A4-10ETDXL A6-12ETDXL A10-12ETDXL A16-12ETDXL mm d 6,9 6,9 7,8 7,8 7,8 8,3 9,8 12 L1 8 10 8 12 10 12 12 12 L 17,5 19,5 17,5 21,5 19,5 23 24 25,5 S 11 13 11 15 13 15 15 15 8:11-18 Crimp tools page 8:5, 8:11-18 Pcs/ pack 100 100 100 100 100 100 100 100

s = stripping length

Certificate FM20987 ISO 9001:2000

2:3www.sourceiec.com

End terminals (ferrules) 0.14 - 50 (185) mm

Un-insulated end terminals 0.25 - 50 mmData: electrolytic copper, tin plated, dimensions according to DIN 46228.mm 0,25 0,5 0,75 Cat. no. B0,25-5ET B0,25-7ET B0,5-6ET B0,5-8ET B0,75-6ET B0,75-8ET B0,75-10ET B1-6ET B1-8ET B1-10ET B1-12ET B1,5-7ET B1,5-10ET B1,5-12ET B2,5-7ET B2,5-10ET B2,5-12ET B2,5-15ET B4-9ET B4-12ET B6-10ET B6-12ET B6-15ET B10-12ET B10-15ET B10-18ET B16-12ET B16-15ET B16-18ET B25-12ET B25-15ET B25-18ET B25-25ET B35-18ET B35-25ET B50-18ET mm d 0,8 0,8 1 1 1,2 1,2 1,2 1,4 1,4 1,4 1,4 1,7 1,7 1,7 2,2 2,2 2,2 2,2 2,8 2,8 3,5 3,5 3,5 4,5 4,5 4,5 5,8 5,8 5,8 7,3 7,3 7,3 7,3 8,3 8,3 10,3 L 5 7 6 8 6 8 10 6 8 10 12 7 10 12 7 10 12 15 9 12 10 12 15 12 15 18 12 15 18 12 15 18 25 18 25 18 s 5 7 6 8 6 8 10 6 8 10 12 7 10 12 7 10 12 15 9 12 10 12 15 12 15 18 12 15 18 12 15 18 25 18 25 18 St/Pack 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 250 250 250 250 250 250 250 250 250 250 250 250 100 100 100 100 1 8:11-18 Crimp tools page 8:5, 8:11-18 Note 1 1 1 1

2

1

1 1

1,5

2,5

1

4 6

10

16

25

35 50

s = strip length Note 1: Not according to DIN 46228. Cross section areas > 50 mm upon request.

2:4www.sourceiec.com

Certificate FM20987 ISO 9001:2000

End terminals (ferrules) 0.14 - 50 (185) mm

Pre-insulated TWIN end terminals 2 x 0.5 - 2 x 10 mmData: electrolytic copper, tin plated, polypropylene insulation, colour code and sizes to DIN 46228. Designed to connect two conductors in one terminal.mm 2 x 0,5 2 x 0,75 2 x 0,75 2x1 2x1 2 x 1,5 2 x 1,5 2 x 2,5 2 x 2,5 2x4 2x6 2 x 10 Cat. no. A0,5-8ET2 A0,75-8ET2 A0,75-10ET2 A1-8ET2 A1-10ET2 A1,5-8ET2 A1,5-12ET2 A2,5-10ET2 A2,5-13ET2 A4-12ET2 A6-14ET2 A10-14ET2 mm d 1,5 1,8 1,8 2,0 2,0 2,3 2,3 2,9 2,9 3,8 4,6 6,5 H/D 2,3/4,5 2,6/5,1 2,6/5,1 3,0/5,1 3,0/5,1 3,5/6,4 3,5/6,4 4,0/7,5 4,0/7,5 4,9/8,6 5,8/9,6 7,0/12,6 L1 8 8 10 8 10 8 12 10 13 12 14 14 L 15,0 15,0 17,0 15,0 17,0 16,0 20 18,5 21,5 23 25 26 s 10 10 12 10 12 10 14 12 15 14 16 16 Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 8:13-18 Crimp tools page * 8:5, 8:11-18

2

s = strip length * Use die nest marked closest to the total cross section area in the terminal

Certificate FM20987 ISO 9001:2000

2:5www.sourceiec.com

Un-insulated terminals 0.2 - 10 mm

Un-insulated terminalsElpress un-insulated ring, tube terminals, forks, pins and connectors are produced from high grade 99.95% copper. The receptacles, tabs, bullets and sockets are produced from brass. All types are electrolytically tin plated for good corrosion protection. Rings, forks and pins have brazed necks to allow crimping in all radial directions.

Example of product designation Cat. no. B1532R (G, HO, FLS etc.) B = un-insulated 15 = conductor crosss section area (1,5 mm) 32 = Characteristic dimension (Hole 3,2 mm) G = fork terminals GS= fork terminal H = tab HN = tab HA = bullet HO = socket R = ring terminal SR = pin FLS = receptacle, rolled type FLSB = receptacle 90 rolled type FLSH = multiple tabs FLSN = receptacle with locking lip FLSV = receptacle angled rolled type

3

Crimped samples of Elpress un-insulated terminals.

MarkingsElpress un-insulated terminals are, when possible, marked with logotype, max. cross section area and possible screw size to facilitate identification, inspection and crimp system work.

3:2www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Un-insulated terminals 0.2 - 10 mm

Ring terminals 0.25 - 6 mmData: Cu 99.95%, tin plated, brazed necks.mm 0,25-0,75 Cat.no. B0832R B0843R B0853R B1532R B1543R B1553R B1565R B1585R B1510R B2532R B2537R B2543R B2553R B2565R B2585R B2510R B4643R B4653R B4665R B4685R B4610R B4613R Screw M3 M4 M5 M3 M4 M5 M6 M8 M10 M3 M3,5 M4 M5 M6 M8 M10 M4 M5 M6 M8 M10 M13 mm W 5,5 7,5 9,0 5,5 7,5 9,0 11,0 14,0 17,0 6,0 6,2 7,5 9,0 11,0 14,0 17,0 7,8 9,0 11,0 14,0 17,0 18,0 d 1,3 1,3 1,3 1,8 1,8 1,8 1,8 1,8 1,8 2,3 2,3 2,3 2,3 2,3 2,3 2,3 3,4 3,4 3,4 3,4 3,4 3,7 t 0,5 0,5 0,5 0,7 0,7 0,7 0,7 0,7 0,75 0,8 0,8 0,8 0,8 0,8 0,8 0,75 1,0 1,0 1,0 1,0 1,0 1,0 L 13,0 16,2 17,0 13,0 16,2 17,0 20 23 26 15,0 16,2 16,2 17,0 20 23 26 17,5 18,0 20 23 26 30 s 7 7 7 7 7 7 7 7 7 8 8 8 8 8 8 8 9 9 9 9 9 9 Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 8:10 Crimp tools page 8:8, 8:12, 8:16-18

0,75-1,5

3

1,5-2,5

4-6

t = palm thickness s = strip length

Tube terminals 0.75 - 10 mmData: Cu 99.95%, tin plated.mm 0,75 1,5 Cat. no. KR0,75-3 KR0,75-4 KR1,5-3 KR1,5-4 KR1,5-5 KR2,5-3 KR2,5-4 KR2,5-5 KR2,5-6 KR4-4 KR4-5 KR4-6 KR6-4 KR6-5 KR6-6 KR6-8 KR10-5 KR10-6 KR10-8 KR10-10 KR10-12 Screw M3 M4 M3 M4 M5 M3 M4 M5 M6 M4 M5 M6 M4 M5 M6 M8 M5 M6 M8 M10 M12 mm W 6,0 6,0 6,5 6,5 7,5 7,5 7,5 8,5 8,5 8,5 9,0 10,0 9,5 9,5 10,0 13,5 11,5 11,5 13,5 16,0 19,0 d 1,3 1,3 1,8 1,8 1,8 2,3 2,3 2,3 2,3 3,0 3,0 3,0 4,0 4,0 4,0 4,0 5,0 5,0 5,0 5,0 5,0 t 0,8 0,8 1,0 1,0 0,8 1,3 1,3 1,2 1,1 1,5 1,5 1,4 1,7 1,7 1,6 1,2 3,0 3,0 2,2 2,0 1,7 L 16,0 16,0 16,0 17,0 18,0 17,0 18,0 19,0 19,0 21 22 23 22 22 23 30 29 29 33 34 41 s 7 7 7 7 7 8 8 8 8 9 9 9 9 9 9 9 11 11 11 11 11 Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 8:10. 8:12 8:16-18 Crimp tools page 8:8, 8:12, 8:16-18

2,5

4

6

10

t = palm thickness s = strip length Larger cross section areas, see next chapter.

Certificate FM20987 ISO 9001:2000

3:3www.sourceiec.com

Un-insulated terminals 0.2 - 10 mm

Fork terminals 0.25 - 10 mmData: Cu 99.95%, tin plated, brazed necks.mm 0,25-0,75 0,75-1,5 Cat. no. B0832G B0843G B1532G B1537GS B1543G B1553G B2532G B2543G B2553G B4643G B4653G B9953G B9965G Screw M3 M4 M3 M3,5 M4 M5 M3 M4 M5 M4 M5 M5 M6 mm W 5,5 7,5 5,5 5,5 7,0 9,0 5,5 7,0 9,0 7,8 9,0 12,0 11,0 d 1,3 1,3 1,8 1,8 1,8 1,8 2,3 2,3 2,3 3,4 3,4 4,6 4,6 t 0,5 0,5 0,7 0,7 0,7 0,7 0,8 0,8 0,8 1,0 1,0 1,2 1,1 L 13,0 16,2 13,0 16,2 16,2 17,0 13,0 16,2 17,0 18,0 18,0 24 23 s 7 7 7 7 7 7 8 8 8 9 9 11 8 Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 100 8:10, 8:16-18 Crimp tools page 8:8, 8:16-18

31,5-2,5

4-6 10

t = palm thickness s = strip length

Pin terminals 0.25 - 6 mmData: Cu 99.95%, tin plated, brazed necks.mm 0,25-0,75 0,75-1,5 1,5-2,5 4-6s = strip length

Cat. no. B0819SR B1519SR B2519SR B4630SR

mm W 1,8 1,9 1,9 2,8

d 1,3 1,8 2,3 3,4

L1 12,0 12,0 12,0 14,0

L 17,0 17,0 17,0 20

s 7 7 8 9

Pcs/ pack 100 100 100 100

Crimp tools page 8:8, 8:16-18, 8:10

Through connectors 0.75 - 10 mmData: Cu 99.95%, tin plated.mm 0,75 1,5 2,5 4 6 10s = strip length

Cat. no. KS0,75 KS1,5 KS2,5 KS4 KS6 KS10 KST10

mm d 1,3 1,8 2,3 3,0 4,0 5,0 4,5

L 14,0 14,0 16,0 19,0 19,0 30 30

s 7 7 8 9 9 16 16

Pcs/ pack 100 100 100 100 100 100 100

Crimp tools page 8:8, 8:16-18

8:10, 8:16-18

3:4www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Un-insulated terminals 0.2 - 10 mm

Receptacles 0.5 - 6 mmData: brass, tin plated.mm 0,5-1 0,75-1,5 Cat. no. B1003FLS5 B1003FLS8 B1505FLS5 B1505FLS8 B1507FLS1 B2505FLS5 B2505FLS8 B2507FLS1 B4607FLS1 mm e 5,0 5,0 6,4 6,4 7,6 6,0 6,0 7,6 7,6 t 0,3 0,3 0,4 0,4 0,4 0,4 0,4 0,4 0,4 L 12,7 12,7 16,0 16,0 19,0 16,0 16,0 19,0 19,0 For tabs 2,8x0,5 2,8x0,8 4,8x0,5 4,8x0,8 6,3x0,8 4,8x0,5 4,8x0,8 6,3x0,8 6,3x0,8 s 7 7 7 7 7 8 8 8 8 Pcs/ pack 100 100 100 100 100 100 100 100 100 Crimp tools page 8:7, 8:9-10, 8:16-18

3

1,5-2,5

4-6

t = palm thickness s = strip length Insulation sleeves, see page 3:10.

Receptacles with locking lip 1.5 - 6 mmData: brass, tin plated.mm 1,5-2,5 4-6 Cat. no. B2507FLSN B4607FLSN mm e 7,5 7,5 t 0,4 0,4 L 19,0 19,0 For tabs 6,3x0,8 6,3x0,8 s 8 9 Pcs/ pack 100 100 Crimp tools page 8:7, 8:9-10, 8:16-18 8:7, 8:9-10, 8:16-18

t = Metal thickness s = strip length Insulation sleeves, see page 3:10. Connector blocks, see page 3:11.

Multiple tabs 0.5 - 2.5 mmData: brass, tin plated.mm 0,5-1,5 1,5-2,5 Cat. no. B1507FLSH B2507FLSH mm e 8,0 8,0 t 0,4 0,4 L 20,0 20,0 For tabs 6,3x0,8 6,3x0,8 s 7 7 Pcs/ pack 100 100 Crimp tools page 8:7, 8:9-10, 8:16-18 8:7, 8:9-10, 8:16-18

t = metal thickness s = strip length

Certificate FM20987 ISO 9001:2000

3:5www.sourceiec.com

Un-insulated terminals 0.2 - 10 mm

Receptacle, 90, 0.5 - 1.5 mmData: brass, tin plated.mm 0,5-1,5 Cat. no. B1507FLSB8 mm e 7,7 t 0,4 L 13,0 For tab 6,3x0,8 s 7 Pcs/ pack 100 Crimp tool page 8:8

t = metal thickness s = strip length

3

Receptacle 90, 0.5 - 1 mmData: brass, tin plated.mm 0,5-1 Cat. no. B1003FLSV5 mm e 4,9 t 0,3 L 9,3 For tabs 2,8x0,5 s 7 Pcs/ pack 100 Crimp tools page 8:7, 8:9-10, 8:16-18

t = metal thickness s = strip length

Tabs 0.5 - 2.5 mmData: brass, tin plated.mm 0,5-1 0,5-1,5 1,5-2,5s = strip length

Cat. no B1003H B1507H B2507H

mm e 5,6 8,0 8,0

L 12,7 19,0 20

Tabs 2,8x0,8 6,3x0,8 6,3x0,8

s 7 7 8

Pcs/ pack 100 100 100

Crimp tools page 8:7, 8:9-10, 8:16-18

Insulation sleeves page 3:10.

Tabs with locking lip 1.5 - 6 mmData: brass, tin plated.mm 0,5-1,0 1,5-2,5 4-6 Cat. no. B1007HN B2507HN B4607HN mm e 16,0 16,0 16,0 L 28 28 28 Tabs 6,3x0,8 6,3x0,8 6,3x0,8 s 8 8 9 Pcs/ pack 100 100 100 Crimp tools page 8:7, 8:9-10, 8:16-18

s = strip length Connector blocks page 3:11.

3:6www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Un-insulated terminals 0.2 - 10 mm

Bullets 0.2 - 2.5 mmData: brass, tin plated.mm 0,2-0,5 1,5-2,5 Cat. no B0502HA B2502HA mm e 5,5 5,5 L 21 21 bullet 2,0 2,0 s 7 8 Pcs/ pack 100 100 Crimp tools page 8:7, 8:9-10, 8:16-18 8:7, 8:9-10, 8:16-18

s = strip length Connector blocks page 3:11.

3

Sockets 0.2 - 2.5 mmData: brass, tin plated.mm 0,2-0,5 1,5-2,5 Cat. no. B0502HO B2502HO mm e 5,5 5,5 L 21 21 For bullet 2,0 s 7 8 Pcs/ pack 100 100 Crimp tools page 8:7, 8:9-10, 8:16-18 8:7, 8:9-10, 8:16-18

s = strip length, connector blocks page 3:11.

Certificate FM20987 ISO 9001:2000

3:7www.sourceiec.com

Un-insulated terminals 0.2 - 10 mm

TabsData: brass, tin plated.Fig 1 2 3 Cat. no. B07FLS1H B07FLS2H B07FLS3H mm W 8,5 9,0 8,0 e 8,0 7,5 7,5 L 8,5 18,5 21 Tabs 6,3x0,8 6,3x0,8 6,3x0,8 Pcs/ pack 100 100 100

3

Fig 4

Cat. no. B07FLS

mm W 7,5

L 9,0

Tabs 6,3x0,8

Pcs/ pack 100

Fig 5 6 7 7

Cat. no. B1803H2 B1805H3 B1807H4 B1807H5

mm W 4,5 6,5 8,1 8,0

e 5,5 7,0 8,3 8,3

2,8 3,2 4,4 5,4

L 13,1 17,5 19,1 19,2

Tabs 2,8x0,8 4,8x0,8 6,3x0,8 6,3x0,8

Pcs/ pack 100 100 100 100

Fig 8 8 9 9

Cat. no. B0457H4 B0457H5 B0907H4 B0907H5

mm b 8,0 8,0 8,0 8,0

e 8,0 8,0 8,3 8,0

4,1 5,3 4,1 5,3

c 8,0 8,0 8,0 8,0

Tabs 6,3x0,8 6,3x0,8 6,3x0,8 6,3x0,8

Pcs/ pack 100 100 100 100

Angle 45 45 90 90

Fig 10 11 11

Cat. no. B2007H4 B2457H4 B2457H5

mm W 7,0 10,0 10,0

c 7 12,0 12,0

e 8,0 8,0 8,0

4,2 4,2 5,2

L 23* 10,0 10,0

Tab 6,3x0,8 6,3x0,8 6,3x0,8

Pcs/ pack 100 100 100

Angle

2x45 2x45

* total length hole diameter.

3:8www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Un-insulated terminals 0.2 - 10 mm

Tabs for solderingData: brass, tin plated.Cat. no. 12523 mm cc 5,0 e 8,5 d 1,5 L 17,0 Tab 6,3x0,8 Pcs/ pack 100

3Cat. no. 17127 17128 mm cc 5,0 5,0 d 1,3 1,2 W 5,0 9,0 L 14,0 16,0 Tab 2,8x0,8 6,3x0,8 Pcs/ pack 100 100

Cat. no. 12610

mm d 0,9

W 6,3

L 10,5

Tab 2,8x0,8

Pcs/ pack 100

Certificate FM20987 ISO 9001:2000

3:9www.sourceiec.com

Un-insulated terminals 0.2 - 10 mm

Insulation bootsData: used together with straight and angled receptacle connections.mm L W 19,0 5,6 21,0 7,6 23 11,0 24 9,0 22,5 9,5 17,3 15,0 Material Colour Polyetylen transp PVC transp PVC transp Polyetylen transp Polyetylen transp PVC transp mm Tab size Max. cable 2,8 2,5 4,8 3,2 6,3 3,6 6,3 2,5 6,3 3,0 6,3 2,5 Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 Temp C -50 +85 -25 +75 -25 +75 -25 +75 -50 +85 -25 +75

Fig. 1

Cat. no. ISO1003FL1 ISO1005FL1 ISO1507H-BW6 ISO1507FLS ISO2507FLS1 ISO1507FLB*

3

2 3 4 5 6

* Used with 90 receptacle

3:10www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Un-insulated terminals 0.2 - 10 mm

Connector blocksused with receptacles and tabs with locking lip 1,5 - 6 mm material PA (nylon) transparent max voltage 250 VACFig 1 2 3 1 2 3 Note 1 2 Used with receptacles B2507FLSN and B4607FLSN. Used with tabs B2507HN and B4607HN. Cat. no. 408/2/M 408/4/M 408/6/M 408/8/M 408/2/F 408/4/F 408/6/F 408/8/F No. of terminals 2 4 6 8 2 4 6 8 mm L 24 24 29 34 32 33 33 33 W 16,4 28 29 38 20 23 31 40 H 9,7 15,3 15,2 15,6 12,7 17,4 18,7 18,6 Pcs/ pack 100 100 100 100 100 100 50 25 Note 1 1 1 1 2 2 2 2

3

Connector blocksused together with sockets and bulltets 0,2 - 2,5 mm material PA (nylon) transparent rated voltage 250 VAC temperature range -20 C to +105 CFig 4 4 5 5 Note 3 4 Used with bullets B0502HA and B2502HA. Used with sockets B0502HO and B2502HO. Cat. no. MC02F MC02M MC03F MC03M MC04F MC04M MC06F MC06M MC09F MC09M MC12F MC12M MC15F MC15M Pol 2 2 3 3 4 4 6 6 9 9 12 12 15 15 mm L 27 27 27 27 27 27 27 27 27 27 27 27 27 26 W 13,6 13,5 19,6 19,6 13,5 13,5 19,6 19,6 19,7 19,7 26 26 32 32 H 7,3 7,3 7,2 7,1 13,5 13,5 13,4 13,4 19,7 19,7 19,6 19,7 19,6 19,9 Pcs/ pack 100 100 100 100 100 100 100 100 100 100 50 50 50 50 Note 3 4 3 4 3 4 3 4 3 4 3 4 3 4

Certificate FM20987 ISO 9001:2000

3:11www.sourceiec.com

Un-insulated terminals 0.2 - 10 mm

Connector blocksused together with receptacles material PVC semi-transparent max voltage 400 VFig Cat. no. 404-1 405-3 401-12 No. of links 1 1+2 12 mm L 48 48 147 W 12,0 21 28 H 6,0 8,5 7,0 Tabs 6,3x0,8 6,3x0,8 6,3x0,8 Pcs/ pack 100 100 50

3

1 2 3

Assortment box PL700Elpress assortment box designed for field service engineers and service departments.

Particulars:manufactured from polyeten 19 partions 700 un-insulated terminals and through connectors 0.75 - 10 mm crimp tool DKB 0325 crimp tool EWB 4099 Miniforce stripping and cutting tool SCT 001 weight 4,3 kg, length 370 mm, width 228 mm, height 37 mm

3:12www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Cu-terminals and connectors 0.75 - 1000 mm

Markings on Cu-connections Cu-connectionsElpress Cu-connections are produced from electrolytic 99.9% copper. Terminals and through connectors exist in a large variety of types for stranded as well as for flexible conductors. C-sleeves for earth conductor branch off also come in a large number of sizes. If a standard type is not suitable, we produce tailor made designs specific to the application. KR/KRF terminals and KS/KSF connectors may be used for both stranded and flexible conductors. KRD terminals and KSD connectors are used for stranded conductors. KRT terminals and KST connectors equal the German "Standard types" (not DIN!) and are used for stranded conductors. C-sleeves are used for branch-off or cross connections for mainly earth conductors such as for lightning protection and earthing grids. By crimping Elpress terminals and connectors with Elpress crimp tools, connections are achieved that meet the requirements of SEN 245010, BS 4579:1, VDE 0220:1, EN-IEC 61238:1 whichever is applicable. Elpress marking system for Cu-connectors shows logotype, conductor area and id-number for crimp die to be used. This system enables final inspection of proper die use as the die number is automatically imprinted by the die on the crimped barrel.

Marking of tap-off C-sleeves

120 - 150/70 - 95120 - 150 = Cu-wire range, mm 70 - 95 = Cu-wire range, mm

4

(Elpress logotype) C16 - 13 Cat.no.

Stud holes in terminal palmsScrewdimension Marking of tube terminals M3 M4 M5 M6 M8 M 10 M 12 M 16 M 20 M 24 Hole diameter tol. H13 ( mm) 3,2 4,3 5,3 6,4 8,4 10,5 13 17 21 25

32 (on the terminal neck)ID-no. for the hexagonal die

(Elpress logo) 300-16F (on the palm)300 = Cu-conductor area, mm 16 = hole for screw M16 F = KRF

Number of crimpsNormally only one crimp per conductor end is needed up to and including 150 mm and two crimps for larger areas. For detailed information see crimp die tables in Chapter 10. If possible multiple crimps should be positioned with a few mm distance from each other and from the neck end. In many cases however, overlapping crimps have to be made for space reasons.

Marking of connectors

(Elpress logo) 27ID-no. for hexagonal die

185 F (possible screen area and an earth-sign)185 = Cu-conductor area, mm F = KSF

Crimp sequence with two adjacent crimps.

4:2www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Cu-terminals and connectors 0.75 - 1000 mm

EasyGuide-to easily introduce flexible conductors into the terminal EasyGuide consists of a stand (EG-TS) and tapered inserts (EG-xx) which are chosen to fit the terminal size. Place the terminal in the guiding groove on one side of the insert and introduce the conductor from the other side, open the insert halves and remove the terminal with the conductor in place. Finally a simple way to get all the strands into the barrel! Suits Elpress type KRF terminals and connectors from 6 to 240 mm.Inserts 6 mm 10 mm 16 mm 25 mm 35 mm 50 mm 70 mm 95 mm 120 mm 150 mm 185 mm 240 mm EG 6 EG 10 EG 16 EG 25 EG 35 EG 50 EG 70 EG 95 EG 120 EG 150 EG 185 EG 240

4

EasyGuide.

Certificate FM20987 ISO 9001:2000

4:3www.sourceiec.com

Cu-terminals and connectors 0.75 - 1000 mm

Tube terminals 0,75 - 10 mm, KRData: electrolytic copper, tin plated, cable inspection hole, for flexible and stranded, Cu-conductors.Marking example KR: 10 10 (Elpress logotype included) 10 = mm 10 = palm hole for M10

Cat. no. mm - bolt hole M KR 0,75-3* KR0,75-4*

mm W 6,0 6,0 6,5 6,5 7,5 7,5 7,5 8,5 8,5 8,5 9,0 10,0 9,5 9,5 10,0 13,5 11,5 11,5 13,5 16,0 19,0

d 1,3 1,3 1,8 1,8 1,8 2,3 2,3 2,3 2,3 3,0 3,0 3,0 4,0 4,0 4,0 4,0 5,0 5,0 5,0 5,0 5,0

N 3,2 3,2 3,4 4,2 4,8 3,5 4,2 4,8 5,1 4,2 4,8 5,0 4,0 5,0 5,5 7,0 6,0 6,0 7,0 8,0 10,0

N1 3,8 3,8 3,6 4,3 4,7 4,1 4,1 4,8 4,9 5,8 5,2 7,0 7,0 6,0 6,5 10,0 7,0 7,0 9,0 10,0 14,0

L 16,0 16,0 16,0 17,0 18,0 17,0 18,0 19,0 19,0 21 22 23 22 22 23 30 29 29 33 34 41

Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100

Crimp tools page 8:9, 8:18-20

4

KR 1,5-3* KR 1,5-4* KR 1,5-5* KR 2,5-3* KR 2,5-4* KR 2,5-5* KR 2,5-6* KR 4-4 KR 4-5 KR 4-6 KR 6-4 KR 6-5 KR 6-6 KR 6-8 KR 10-5 KR 10-6 KR 10-8 KR10-10 KR10-12* no inspection hole

8:11

9:3

9:4-30

4:4www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Cu-terminals and connectors 0.75 - 1000 mm

Tube terminals 16 - 800 mm, KRFData: electrolytic copper, tin plated, cable inspection hole, for flexible and stranded, Cu-conductors.Marking example KRF: 70 10F, KRD: 500 16 (Elpress logotype included) 70 = mm 500 = mm 10 = palm hole for M10 16 = palm hole for M16 F = type KRF, for stranded and flexible conductors

Cat. no. mm - bolt hole M KRF 16-6 KRF 16-8 KRF 16-10 KRF 16-12 KRF 25-6 KRF 25-8 KRF 25-10 KRF 25-12 KRF 35-6 KRF 35-8 KRF 35-10 KRF 35-12 KRF 50-6 KRF 50-8 KRF 50-10 KRF 50-12 KRF 50-16 KRF 70-6 KRF 70-8 KRF 70-10 KRF 70-12 KRF 70-16 KRF 95-8 KRF 95-10 KRF 95-12 KRF 95-16 KRF 120-10 KRF 120-12 KRF 120-16 KRF 150-10 KRF 150-12 KRF 150-16 KRF 150-20 KRF 185-10 KRF 185-12 KRF 185-16 KRF 185-20 KRF 240A-10 KRF 240A-12 KRF 240A-16 KRF 240A-20 KRF 300A-10 KRF 300A-12 KRF 300A-16 KRF 300A-20 KRF 300A-24* no inspection hole ** total palm length

mm W 13,0 13,0 16,0 22 16,0 16,0 17,0 22 18,0 18,0 18,0 22 21 21 21 21 27 25 25 25 25 28 29 29 29 29 32 32 32 36 36 36 36 39 39 39 39 42 42 42 42 45 45 45 45 45

d 6,0 6,0 6,0 6,0 8,0 8,0 8,0 8,0 9,0 9,0 9,0 9,0 11,0 11,0 11,0 11,0 11,0 13,0 13,0 13,0 13,0 13,0 15,0 15,0 15,0 15,0 17,0 17,0 17,0 19,0 19,0 19,0 19,0 21 21 21 21 22,5 22,5 22,5 22,5 24,5 24,5 24,5 24,5 24,5

N 8,0 8,0 10,0 12,0 8,0 8,0 10,0 12,0 10,0 10,0 10,0 12,0 11,0 11,0 11,0 12,0 15,0 11,0 11,0 11,0 12,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 19,0 15,0 15,0 15,0 19,0 19 19 19 19 22 22 22 22 22

N1 9,0 9,0 11,0 13,0 10,0 10,0 11,0 13,0 11,0 11,0 11,0 14,0 12,0 12,0 12,0 14,0 17,0 12,0 12,0 12,0 14,0 17,0 17,0 17,0 17,0 17,0 17,0 17,0 17,0 17,0 17,0 17,0 20 17,0 17,0 17,0 20 20 20 20 20 32 32 32 32 32

L 34 34 38 47 39 39 42 47 47 47 47 52 50 50 50 53 59 55 55 55 58 64 69 69 69 69 73 73 73 80 80 80 87 86 86 86 93 96 96 96 96 116 116 116 116 116

Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 50 50 50 50 50 25 25 25 25 25 25 25 20 20 20 20 10 10 10 10 10 10 10 10 10

Die no. 9 9 9 9 11 11 11 11 13 13 13 13 14,5 14,5 14,5 14,5 14,5 17 17 17 17 17 20 20 20 20 22 22 22 25 25 25 25 27 27 27 27 30 30 30 30 32 32 32 32 32

Crimp tools page 9:3-6 9:8-30

4

9:13-30

Certificate FM20987 ISO 9001:2000

4:5www.sourceiec.com

Cu-terminals and connectors 0.75 - 1000 mm

Cat. no. mm - bolt hole M KRF 400A-00 KRF 400A-12 KRF 400A-16 KRF 400A-20 KRF 400A-24

mm W 56 56 56 56 56

d 30 30 30 30 30

N 22 22 22 22

N1 33 33 33 33

L 125 125 125 125 125

Pcs/ pack 10 10 10 10 10

Die no. 38 38 38 38 38

Crimp tools page 9:13-15 9:23-30

For flexible Cu-conductorsKRF 500-00 KRF 500-16 KRF 500-20 KRF 500-24 KRF 630-00 KRF 630-20 KRF 630-24 KRF 800-00 KRF 800-24 61 61 61 61 75 75 75 75 75 33 33 33 33 39 39 39 42 42 70** 25 25 25 80** 35 35 80** 35 35 35 35 45 45 45 160 150 150 150 195 195 195 195 195 5 5 5 5 1 1 1 1 1 42 42 42 42 53 53 53 53 53 9:35-36

4

9:23-25

For stranded Cu-conductorsKRD 500-00 KRD 500-16 KRD 500-20 KRD 500-24 KRD 630-00 KRD 630-20 KRD 630-24 KRD 800-00 KRD 800-24 KRD 1000-00* no inspection hole ** total palm length

58 58 58 58 65 65 65 75 75 80

31 31 31 31 34 34 34 39 39 43

70** 25 25 25 75** 25 25 80** 35 80**

35 35 35 35 35 45

160 150 150 150 165 150 150 195 195 195

5 5 5 5 1 1 1 1 1 1

40 40 40 40 45 45 45 53 53 56

9:23-30

9:23-25

4:6www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Cu-terminals and connectors 0.75 - 1000 mm

Tube terminals 10 - 1000 mm, KRTData: electrolytic copper, tin plated, cable inspection hole, for stranded and round, compressed Cu-conductors.Marking example KRT: 70 10 (Elpress logotype included) 70 = mm 10 = palm hole for M10

Cat. no. KRT 10-5 KRT 10-6 KRT 10-8 KRT 10-10 KRT 10-12 KRT 16-5 KRT 16-6 KRT 16-8 KRT 16-10 KRT 16-12 KRT 25-6 KRT 25-8 KRT 25-10 KRT 25-12 KRT 35-6 KRT 35-8 KRT 35-10 KRT 35-12 KRT 50-6 KRT 50-8 KRT 50-10 KRT 50-12 KRT 70-8 KRT 70-10 KRT 70-12 KRT 95-8 KRT 95-10 KRT 95-12 KRT 95-16 KRT 120-10 KRT 120-12 KRT 120-16 KRT 150-12 KRT 150-16 KRT 150-20 KRT 185-12 KRT 185-16 KRT 185-20 KRT 240-12 KRT 240-16 KRT 240-20 KRT 300-12 KRT 300-16 KRT 300-20 KRT 400-16 KRT 400-20 KRT 400-24

mm W 10 10 13 16 19 12 12 15 16 19 14 15 16 19 17 17 19 22 20 20 20 22 23 23 23 26 26 26 28 28 28 28 32 32 32 35 35 35 38 38 38 44 44 44 48 48 48

d 4,5 4,5 4,5 4,5 4,5 5,5 5,5 5,5 5,5 5,5 7 7 7 7 8,5 8,5 8,5 8,5 10 10 10 10 12 12 12 13,5 13,5 13,5 13,5 15 15 15 17 17 17 19 19 19 21 21 21 24 24 24 26 26 26

N 6 6 8 8 10 6 6 8 8 10 9 9 9 12 9,5 9,5 9,5 12 11 11 11 12 11 11 12 11 11 12 15 11 12 15 15 15 19 15 15 19 15 15 19 19 19 19 21 21 21

N1 8 8 11 11 14 8 8 11 11 15 12 12 12 13 11,5 11,5 11,5 14 12 12 12 14 12 12 14 12 12 14 17 14 14 17 17 17 20 17 17 20 17 17 20 20 20 20 31 31 31

L 29 29 34 34 41 34 34 39 39 47 43 43 43 48 49 49 49 53 53 53 53 56 55 55 58 60 60 63 69 64 64 70 76 76 83 79 79 86 86 86 93 100 100 100 114 114 114

Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 50 50 50 50 50 25 25 25 25 25 25

Die no. 7 7 7 7 7 8,5 8,5 8,5 8,5 8,5 10 10 10 10 12 12 12 12 14 14 14 14 16 16 16 18 18 18 18 19 19 19 22 22 22 24 24 24 26 26 26 30 30 30 32 32 32

Crimp tools page 9:3-9:6 9:8-30

4

9:13-30

Certificate FM20987 ISO 9001:2000

4:7www.sourceiec.com

Cu-terminals and connectors 0.75 - 1000 mm

Cat. no. KRT 500-00 KRT 500-16 KRT 500-20 KRT 500-24 KRT 630-00 KRT 630-20 KRT 630-24 KRT 800-00 KRT 800-24

mm W 58 58 58 58 65 65 65 75 75 80

d 31 31 31 31 34 34 34 39 39 43

N 70** 25 25 25 70** 25 25 80** 35 80**

N1 35 35 35 35 35 45 -

L 160 150 150 150 160 150 150 195 195 195

Pcs/ pack -

Die no. 40 40 40 40 45 45 45 53 53 56

Crimp tools page 9:23-36

9:23-25

9:35-36

4

KRT 1000-00

4:8www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Cu-terminals and connectors 0.75 - 1000 mm

Tube terminals 16 - 1000 mm, KRDData: electrolytic copper, tin plated, cable inspection hole, for stranded and and round, compressed Cu-conductors.Marking example KRD: 70 10 (Elpress logotype included) 70 = mm 10 = palm hole for M10 Cat. no. KRD 16-5 KRD 16-6 KRD 16-8 KRD 16-10 KRD 16-12 KRD 25-6 KRD 25-8 KRD 25-10 KRD 25-12 KRD 35-6 KRD 35-8 KRD 35-10 KRD 35-12 KRD 50-6 KRD 50-8 KRD 50-10 KRD 50-12 KRD 70-8 KRD 70-10 KRD 70-12 KRD 95-8 KRD 95-10 KRD 95-12 KRD 95-16 KRD 120-10 KRD 120-12 KRD 120-16 KRD 150-12 KRD 150-16 KRD 150-20 KRD 185-12 KRD 185-16 KRD 185-20 KRD 240-12 KRD 240-16 KRD 240-20 KRD 300-12 KRD 300-16 KRD 300-20 KRD 400-16 KRD 400-20 KRD 400-24 KRD 500-00 KRD 500-16 KRD 500-20 KRD 500-24 KRD 630-00 KRD 630-20 KRD 630-24 KRD 800-00 KRD 800-24 KRD 1000-00 mm W 12 12 14 16 18 13 13 16 22 16 16 17 22 18 18 18 20 22 22 22 24 24 24 28 28 28 28 32 32 32 36 36 36 39 39 39 44 44 44 48 48 48 58 58 58 58 65 65 65 75 75 80 d 5,4 5,4 5,4 5,4 5,4 6,7 6,7 6,7 6,7 8 8 8 8 9,5 9,5 9,5 9,5 11,3 11,3 11,3 13 13 13 13 15 15 15 17 17 17 19 19 19 21 21 21 24 24 24 26 26 26 31 31 31 31 34 34 34 39 39 43 N 6 6 8 8 10 7 7 10 12 8 8 10 12 8,5 8,5 9,5 12 11 11 12 11 11 12 15 11 11 15 15 15 19 15 15 19 15 15 19 19 19 19 22 22 22 70** 25 25 25 75** 25 25 80** 35 80** N1 8 8 9 10 14 9 9 12 13 10 10 11 13 11,5 11,5 11,5 14 12 12 14 12 12 14 17 15 15 17 17 17 20 17 17 20 17 17 20 20 20 20 31 31 31 35 35 35 35 35 45 L 29 29 33 34 41 32 32 38 47 39 39 42 47 44 44 49 53 54 54 57 58 58 61 67 64 64 70 76 76 83 80 80 87 86 86 93 100 100 100 116 116 116 160 150 150 150 165 150 150 195 195 195 Pcs/pack 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 25 25 25 25 25 25 5 5 5 5 1 1 1 1 1 1 Die no. 8 8 8 8 8 9 9 9 9 11 11 11 11 12 12 12 12 14 14 14 16 16 16 16 19 19 19 22 22 22 25 25 25 27 27 27 30 30 30 32 32 32 40 40 40 40 45 45 45 53 53 56 9:13-30 Crimp tools page 9:3-6 9:8-30

4

9:23-30

9:35-36

9:23-25

Certificate FM20987 ISO 9001:2000

4:9www.sourceiec.com

Cu-terminals and connectors 0.75 - 1000 mm

Tube terminals with two stud holes 70 - 400 mm, KRFData: electrolytic copper, tin plated, cable inspection hole, for flexible and stranded Cu-conductors.Marking example KRF: 70 10F (Elpress logotype included) 70 = mm 10 = palm hole for M10 F = type KRF, for flexible and stranded conductors

Cat. no. mm, bolt hole, cc-measure KRF 70-12X2-40 KRF 95-12X2-40

mm W 25 29 32 36 39 42 45 56

d 13,0 15,0 17,0 19,0 21 22,5 24,5 30

N

N1

L

Pcs/ pack 25 25 25 20 20 10 10 10

Die no. 17 20 22 25 27 30 32 38

Crimp tools page 9:3-4 9:5-14

12 18 103 12 18 109 12 19 113 12 19 120 12 20 126 12 21 130 12 22 136 12 23 145

4

KRF 120-12X2-40 KRF 150-12X2-40 KRF 185-12X2-40 KRF 240A-12X2-40 KRF 300A-12X2-40 KRF 400A-12X2-40

9:13-30

Tube terminals 45, 10 - 150 mm, KRFData: electrolytic copper, tin plated, cable inspection hole, for flexible and stranded, Cu-conductors.Marking example KRF: 70 10F (Elpress logotype included) 70 = mm 10 = palm hole for M10 F = type KRF, for stranded and flexible conductors

Cat. no. mm, Bolt, 45 KR 10-6-45GR KR 10-8-45GR KRF 16-6-45GR KRF 16-8-45GR KRF 25-6-45GR KRF 25-8-45GR KRF 25-10-45GR KRF 35-6-45GR KRF 35-8-45GR KRF 35-10-45GR KRF 50-8-45GR KRF 50-10-45GR KRF 50-12-45GR KRF 70-8-45GR KRF 70-10-45GR KRF 70-12-45GR KRF 95-10-45GR KRF 95-12-45GR KRF 95-16-45GR KRF 120-10-45GR KRF 120-12-45GR KRF 120-16-45GR KRF 150-10-45GR KRF 150-12-45GR KRF 150-16-45GR

mm W 13,0 13,5 13,0 13,5 17,0 17,0 17,0 18,0 18,0 18,0 21 21 21 25 25 25 29 29 29 32 32 32 36 36 36

d 5,0 5,0 6,0 6,0 8,0 8,0 8,0 9,0 9,0 9,0 11,0 11,0 11,0 13,0 13,0 13,0 15,0 15,0 15,0 17,0 17,0 17,0 19,0 19,0 19,0

N 6,5 8,5 6,5 8,5 6,5 8,5 11,5 6,5 8,5 11,5 8,5 11,5 12,5 8,5 11,5 12,5 11,5 12,5 15,5 11,5 12,5 15,5 11,5 12,5 15,5

N1 11,5 12,0 11,5 12,0 11,5 12,0 13,5 11,5 12,0 13,5 17,5 18,5 19,5 17,5 18,5 19,5 18,5 19,5 20,5 18,5 19,5 20,5 18,5 19,5 20,5

A 19 19 23 23 24 24 24 30 30 30 31 31 31 35 35 35 40 40 40 43 43 43 49 49 49

Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 50 50 25 25 25 25 25 25

Die no. 8 8 9 9 11 11 11 13 13 13 14,5 14,5 14,5 17 17 17 20 20 20 22 22 22 25 25 25

Crimp tools page 9:3-6 9:8-30

4:10www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Cu-terminals and connectors 0.75 - 1000 mm

Tube terminals 45, 10 - 120 mm, KRTData: electrolytic copper, tin plated, without cable inspection hole, for stranded, round, compressed Cu-conductors.Marking example KRT: 70 10 (Elpress logotype included) 70 = mm 10 = palm hole for M10

Cat. no. KRT 10-6NS-45GR KRT 10-8NS-45GR KRT 16-6NS-45GR KRT 16-8NS-45GR KRT 16-10NS-45GR KRT 25-6NS-45GR KRT 25-8NS-45GR KRT 25-10NS-45GR KRT 35-6NS-45GR KRT 35-8NS-45GR KRT 35-10NS-45GR KRT 50-8NS-45GR KRT 50-10NS-45GR KRT 50-12NS-45GR KRT 70-8NS-45GR KRT 70-10NS-45GR KRT 70-12NS-45GR KRT 95-8NS-45GR KRT 95-10NS-45GR KRT 95-12NS-45GR KRT 95-16NS-45GR KRT 120-10NS-45GR KRT 120-12NS-45GR KRT 120-16NS-45GR

mm W 13 13,5 13 13,5 16 14 14 16 17 17 19 20 20 22 23 23 23 28 28 28 28 29 29 29

d 4,5 4,5 5,4 5,4 5,4 7 7 7 8,5 8,5 8,5 10 10 10 12 12 12 13,5 13,5 13,5 13,5 15 15 15

N 6,5 8,5 6,5 8,5 11,5 6,5 8,5 11,5 6,5 8,5 11,5 8,5 11,5 12,5 8,5 11,5 12,5 8,5 11,5 12,5 15,5 11,5 12,5 15,5

N1 11,5 12 11,5 12 13,5 11,5 12 13,5 11,5 12 13,5 17,5 18,5 19,5 17,5 18,5 19,5 17,5 18,5 19,5 20,5 18,5 19,5 20,5

A 20 20 23 23 23 26 26 26 30 30 30 32 32 32 38 38 38 38 38 38 38 41 41 41

Pcs/pack 100 100 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 50 50 50 25 25 25

Die no. 7 7 8,5 8,5 8,5 10 10 10 12 12 12 14 14 14 16 16 16 18 18 18 18 19 19 19

Crimp tools page 9:3-6 9:8-30

4

Certificate FM20987 ISO 9001:2000

4:11www.sourceiec.com

Cu-terminals and connectors 0.75 - 1000 mm

Tube terminals 90 degrees 10 - 150 mm, KRFData: electrolytic copper, tin plated, cable inspection hole, for flexible and stranded, Cu-conductors.Marking example KRF: 70 10F (Elpress logotype included) 70 = mm 10 = palm hole for M10 F = type KRF, for flexible and stranded conductors

Cat. no. mm, Bolt KR 10-6-90GR KR 10-8-90GR

mm W 13,0 13,5 13,0 13,5 17,0 17,0 17,0 18,0 18,0 18,0 21 21 21 25 25 25 29 29 29 32 32 32 36 36 36

d 5,0 5,0 6,0 6,0 8,0 8,0 8,0 9,0 9,0 9,0 11,0 11,0 11,0 13,0 13,0 13,0 15,0 15,0 15,0 17,0 17,0 17,0 19,0 19,0 19,0

N 6,5 8,5 6,5 8,5 6,5 8,5 11,5 6,5 8,5 11,5 8,5 11,5 12,5 8,5 11,5 12,5 11,5 12,5 15,5 11,5 12,5 15,5 11,5 12,5 15,5

N1 11,5 12,0 11,5 12,0 11,5 12,0 13,5 11,5 12,0 13,5 17,5 18,5 19,5 17,5 18,5 19,5 18,5 19,5 20,5 18,5 19,5 20,5 18,5 19,5 20,5

A 15 15 17 17 18,5 18,5 18,5 22,5 22,5 22,5 30,5 30,5 30,5 31,5 31,5 31,5 32,5 32,5 32,5 34,5 34,5 34,5 37,5 37,5 37,5

Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 50 50 25 25 25 25 25 25

Die no. 8 8 9 9 11 11 11 13 13 13 14,5 14,5 14,5 17 17 17 20 20 20 22 22 22 25 25 25

Crimp tools page 9:3-6 9:8-30

4

KRF 16-6-90GR KRF 16-8-90GR KRF 25-6-90GR KRF 25-8-90GR KRF 25-10-90GR KRF 35-6-90GR KRF 35-8-90GR KRF 35-10-90GR KRF 50-8-90GR KRF 50-10-90GR KRF 50-12-90GR KRF 70-8-90GR KRF 70-10-90GR KRF 70-12-90GR KRF 95-10-90GR KRF 95-12-90GR KRF 95-16-90GR KRF 120-10-90GR KRF 120-12-90GR KRF 120-16-90GR KRF 150-10-90GR KRF 150-12-90GR KRF 150-16-90GR

System 1300 and 1400 can not crimp KR/KRF 10 - 35 mm, as the terminal necks are too short. Use V500, V611 or T2600 instead.

4:12www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Cu-terminals and connectors 0.75 - 1000 mm

Tube terminals 90 degrees 10 - 120 mm, KRTData: electrolytic copper, tin plated, for stranded, round, compressed Cu-conductors. KRTtypes are without inspection hole (NS).Marking example: 70 10 (Elpress logotype included) 70 = mm 10 = palm hole for M10

Cat. no. KRT 10-6NS-90GR KRT 10-8NS-90GR KRT 16-6NS-90GR KRT 16-8NS-90GR KRT 16-10NS-90GR KRT 25-6NS-90GR KRT 25-8NS-90GR KRT 25-10NS-90GR KRT 35-6NS-90GR KRT 35-8NS-90GR KRT 35-10NS-90GR KRT 50-6NS-90GR KRT 50-8NS-90GR KRT 50-10NS-90GR KRT 70-8NS-90GR KRT 70-10NS-90GR KRT 70-12NS-90GR KRT 95-8NS-90GR KRT 95-10NS-90GR KRT 95-12NS-90GR KRT 95-16NS-90GR KRT 120-10NS-90GR KRT 120-12NS-90GR KRT 120-16NS-90GR

mm W 13 13,5 13 13,5 16 14 14 16 17 17 19 22 20 20 23 23 23 28 28 28 28 28 28 28

d 4,5 4,5 5,4 5,4 5,4 7 7 7 8,5 8,5 8,5 10 10 10 12 12 12 13,5 13,5 13,5 13,5 15 15 15

N 6,5 8,5 6,5 8,5 11,5 6,5 8,5 11,5 6,5 8,5 11,5 8,5 11,5 12,5 8,5 11,5 12,5 8,5 11,5 12,5 15,5 11,5 12,5 15,5

N1 11,5 12 11,5 12 13,5 11,5 12 13,5 11,5 12 13,5 12 17,5 18,5 17,5 18,5 19,5 17,5 18,5 19,5 20,5 18,5 19,5 20,5

A 15,5 15,5 16,5 16,5 17 20 20 20 23,5 23,5 23,5 32,5 31,5 31,5 32,5 32,5 32,5 32,5 32,5 32,5 32,5 34,5 34,5 34,5

Pcs/Pack 100 100 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 50 50 50 25 25 25

Die no. 7 7 8,5 8,5 8,5 10 10 10 12 12 12 14 14 14 16 16 16 18 18 18 18 19 19 19

Crimp tools page 9:3-6, 9:8-30

4

System 1300 and 1400 can not crimp KR/KRF 10 - 35 mm, as the terminal necks are too short. Use V500, V611 or T2600 instead.

Certificate FM20987 ISO 9001:2000

4:13www.sourceiec.com

Cu-terminals and connectors 0.75 - 1000 mm

Tube terminals 10 - 300 mm DIN 46235Data: electrolytic copper, tin plated, dimensions according to DIN 46235, number of crimps marked on the neck of the terminal.Palm marking example: 70 10 70 = mm 10 = palm hole for M10

Cat. no. mm, bolt KR 10-6 DIN

mm W 9,0 13,0 13,0 17,0 14,0 16,0 17,0 19,0 17,0 19,0 21 20 22 23 28 24 24 30 28 28 32 32 32 38 34 34 40 36 36 36 42 42 45 48 48

d 4,5 5,5 5,5 5,5 7,0 7,0 7,0 7,0 8,2 8,2 8,2 10,0 10,0 10,0 10,0 11,5 11,5 11,5 13,5 13,5 13,5 15,5 15,5 15,5 17,0 17,0 17,0 19,0 19,0 19,0 22 22 22 24 24

L 27 36 36 36 38 38 38 38 42 42 42 52 52 52 52 55 55 55 65 65 65 70 70 70 78 78 78 82 82 82 92 92 92 100 100

Pcs/ pack 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 50 50 25 25 25 25 25 25 25 25 25 25 25 25 10 10

DIN die no. 6 8 8 8 10 10 10 10 12 12 12 14 14 14 14 16 16 16 18 18 18 20 20 20 22 22 22 25 25 25 28 28 28 32 32

Crimp tools page 9:6, 9:10, 9:15, 9:20

4

KR 16-6 DIN KR 16-8 DIN KR 16-10 DIN KR 25-6 DIN KR 25-8 DIN KR 25-10 DIN KR 25-12 DIN KR 35-8 DIN KR 35-10 DIN KR 35-12 DIN KR 50-8 DIN KR 50-10 DIN KR 50-12 DIN KR 50-16 DIN KR 70-10 DIN KR 70-12 DIN KR 70-16 DIN KR 95-10 DIN KR 95-12 DIN KR 95-16 DIN KR 120-12 DIN KR 120-16 DIN KR 120-20 DIN KR 150-12 DIN KR 150-16 DIN KR 150-20 DIN KR 185-12 DIN KR 185-16 DIN KR 185-20 DIN KR 240-12 DIN KR 240-16 DIN KR 240-20 DIN KR 300-16 DIN KR 300-20 DIN

4:14www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Cu-terminals and connectors 0.75 - 1000 mm

Sheet metal terminals 10 - 240 mm DIN 46234Data: electrolytic copper, tin plated, dimensions according to DIN 46234.Cat. no. mm, bolt B 10-5R B 10-6R B 10-8R B 10-10R B 10-12R B 16-5R B 16-6R B 16-8R B 16-10R B 16-12R B 25-5 B 25-6R B 25-8R B 25-10R B 25-12R B 25-16R B 35-6R B 35-8R B 35-10R B 35-12R B 35-16R B 50-6R B 50-8R B 50-10R B 50-12R B 50-16R B 70-8R B 70-10R B 70-12R B 70-16R B 95-10R B 95-12R B 95-16R B 120-10R B 120-12R B 120-16R B 150-12R B 150-16R B 185-12R B 185-16R B 240-12R B 240-16R mm W 10,0 11,0 14,0 18,0 22 11,0 11,0 14,0 18,0 22 12,0 12,0 16,0 18,0 22 28 15,0 16,0 18,0 22 28 18,0 18,0 18,0 22 28 22 22 22 28 24 24 28 24 24 28 30 30 36 36 38 38 d 4,5 4,5 4,5 4,5 4,5 5,8 5,8 5,8 5,8 5,8 7,5 7,5 7,5 7,5 7,5 7,5 9,0 9,0 9,0 9,0 9,0 11,0 11,0 11,0 11,0 11,0 13,0 13,0 13,0 13,0 15,0 15,0 15,0 16,5 16,5 16,5 19,0 19,0 21 21 24 24 N1 5,0 5,5 7,0 9,0 11,0 5,5 5,5 7,0 9,0 11,0 6,0 6,0 8,0 9,0 11,0 14,0 7,5 8,0 9,0 11,0 14,0 9,0 9,0 9,0 11,0 14,0 11,0 11,0 11,0 14,0 12,0 12,0 14,0 12,0 12,0 14,0 15,0 15,0 18,0 18,0 19,0 19,0 N 8,0 9,0 12,0 13,0 15,0 10,0 10,0 12,0 14,0 16,0 14,0 14,0 14,0 15,0 20 24 14,0 14,0 15,0 19,0 24 18,0 18,0 18,0 20 24 20 20 20 24 22 22 24 22 22 26 26 26 22 22 24 24 L 21 23 27 30 34 26 26 29 33 37 31 31 33 35 42 49 34 34 36 42 50 43 43 43 47 54 49 49 49 56 54 54 58 56 56 62 65 65 74 74 75 75 Pcs/ pack 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 50 50 50 50 50 Palm marking 10 10 10 10 10 16 16 16 16 16 25 25 25 25 25 25 35 35 35 35 35 50 50 50 50 50 70 70 70 70 95 95 95 120 120 120 150 150 185 185 240 240 Crimp tools page Please contact Elpress

4

Certificate FM20987 ISO 9001:2000

4:15www.sourceiec.com

Cu-terminals and connectors 0.75 - 1000 mm

Terminals with narrow palm 35 - 240 mmData: electrolytic copper, tin plated, for stranded conductors.Cat. no. KRTS 35-6 KRTS 50-6 KRTS 50-8 KRTS 50-10 KRTS 70-6 KRTS 70-8 KRTS 70-10 KRTS 70-12 KRTS 95-6 KRTS 95-8 KRTS 95-10 KRTS 95-12 KRTS 120-6 KRTS 120-8 KRTS 120-10 KRTS 120-12 KRTS 150-6 KRTS 150-8 KRTS 150-10 KRTS 150-12 KRTS 185-6 KRTS 185-8 KRTS 185-10 KRTS 240-6 KRTS 240-8 KRTS 240-10 mm W 15 15 17 19 17 17 19 22 19 19 19 22 19 19 19 22 19 19 19 22 30 30 30 30 30 30 d 8,5 10 10 10 12 12 12 12 13,5 13,5 13,5 13,5 15 15 15 15 16,5 16,5 16,5 16,5 19 19 19 21 21 21 N 7,5 7,5 10 12 7,5 10 12 13 7,5 10 12 13 7,5 10 12 13 7,5 10 12 13 12 13 16 12 13 16 L 41 45,5 48 51,5 52,5 54 56,5 58 54,5 57 59 61 59,5 62 65 67 65,5 68 70 71,5 75 78 81 81 80 88 Pcs/Pack 100 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 Die no. 12 14 14 14 16 16 16 16 18 18 18 18 19 19 19 19 22 22 22 22 24 24 24 26 26 26 Crimp tools page 9:3-6 9:8-30

4

4:16www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Cu-terminals and connectors 0.75 - 1000 mm

Through connectors 0,75 - 800 mm, KS/KSFData: electrolytic copper, tin plated, cable inspection hole and cable stop, for flexible and stranded Cu-conductorsMarking example: 20 95F 111 (earth-sign) Elpress logotype included 20 = die no. 95 = mm F = type KSF, stranded and flexible conductors 111 = screen, mm

Cat. no. mm KS 0,75 KS 1,5 KS 2,5 KS4 KS6 KS10 KSF 16 KSF 25 KSF 35 KSF 50 KSF 70 KSF 95 KSF 120 KSF 150 KSF 185 KSF 240A KSF 300A KSF 400A KSF 500 KSF 630 KSF 800

Screen cross section

mm d 1,3 1,8 2,3 3,0 4,0 5,0

D 2,8 3,3 4,2 5,0 6,0 8,0 9,0 11,0 13,0 14,5 17,0 20 22 25 27 29 31,5 38 42 53 53

L 14,0 14,0 16,0 19,0 19,0 30 35 35 35 45 45 45 55 65 70 70 75 100 135 175 175

Pcs/ pack 100 100 100 100 100 100 100 100 100 50 50 50 50 25 25 25 10 10 5

Crimp tools page 8:9 , 8:18-20 9:3-6 9:8-30

4

15 21-29 41 57 72-88 111

6,0 8,0 9,0 11,0 13,0 15,0 17,0 19,0 21 22,5 24 30 33 39 42

9:13-15 9:13-15 9:23-30 9:23-30, 9:35-36 9:23-25

Certificate FM20987 ISO 9001:2000

4:17www.sourceiec.com

Cu-terminals and connectors 0.75 - 1000 mm

Through connectors 16 - 800 mm, KSD/KSTData: electrolytic copper, tin plated, cable inspection hole and cable stop, for stranded, round, compressed Cu-conductors.Marking example: 18 95 Elpress logotype included 18 = die no. 95 = mm

Cat. no. KSD 16 KSD 25 KSD 35 KSD 50 KSD 70 KSD 95 KSD 120 KSD 150 KSD 185 KSD 240 KSD 300 KSD 400 KSD 500 KSD 630 KSD 800 KST10 KST 16 KST 25 KST 35 KST 50 KST 70 KST 95 KST 120 KST 150 KST 185 KST 240 KST 300 KST 400 KST 500 KST 630 KST 800

mm d 5,4 6,7 8 9,5 11,3 13 15 17 19 21 24 26 31 34 39 4,5 5,5 7 8,5 10 12 13,5 15 17 19 21 24 26 31 34 39

D 8 9 11 12 14 16 19 22 25 27 30 32 40 45 53 7 8,5 10 12 14 16 18 19 22 24 26 30 32 40 45 53

L 35 30 35 40 45 55 60 65 70 70 90 90 135 135 175 30 35 40 45 50 55 60 60 65 75 85 90 90 135 135 175

Pcs/Pack 100 100 100 50 50 50 50 50 50 50 50 25 5 5 1 100 100 100 100 50 50 50 50 50 50 50 50 50 5 9:3-6

Crimp tools page 9:8-30

4

9:23-36

9:3-6

9:8-30

9:23-30 9:23-30 9:23-25

9:35-36

4:18www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Cu-terminals and connectors 0.75 - 1000 mm

Through connectors with partition 10 - 400 mmData: electrolytic copper, tin plated, with partition to prevent oilleakage, for flexible and stranded, Cu-conductorsMarking example: 20 95F 111 (earth-sign) Elpress logotype included 20 = die no. 95 = mm F = type KSF, stranded and flexible conductors 111 = screen, mm

Cat. no. mm KS 10M KSF 16M KSF 25M KSF 35M KSF 50M KSF 70M KSF 95M KSF 120M KSF 150M KSF 185M KSF 240AM KSF 300AM KSF 400AM

Screen cond. area

mm d 5,0

D 8,0 9,0 11,0 13,0 14,5 17,0 20 22 25 27 29 31,5 38

L 36 37 38 41 48 49 56 63 64 74 76 88 105

Pcs/ pack 100 100 100 100 50 50 50 50 25 25 25 10 10

Crimp tools page 9:3-6 9:8-30

15 21-29 41 57 72-88 111

6,0 8,0 9,0 11,0 13,0 15,0 17,0 19,0 21 22,5 24,5 30

4

9:13-15 9:23-30

Parallel connectors for total cross section areas 0.5 - 7.5 mmData: electrolytic copper, tin plated.mm Total 0,5-1,5 1,5-3,5 4-7,5 Cat. no. KS2x1P KS2x2,5P KS2x6P mm d 1,6 2,3 3,6 D 3,2 3,9 5,6 L 7,0 2,3 3,6 Pcs/ pack 100 100 100 Marking Crimp tools page 8:9, 8:11 8:9, 8:11 8:11

Connectors for solid Cu conductors 6 - 16 mmData: electrolytic copper, for solid conductors (to IEC 60228 class 1).mm 6 10 10 16 Cat. no. CUT 6 CUT 10 KS10CUT10** CUT 16 mm d 3,0 4,0 5,0/4,0 5,0 D 5,0 6,0 8,0/6,0 8,0 L 27 27 32 35 Pcs/ pack 100 100 100 100 Marking* CUT6 CUT10 KS10CUT10 CUT16 Crimp tools page 9:3

* Elpress logotype included in marking. ** Tin plated

Certificate FM20987 ISO 9001:2000

4:19www.sourceiec.com

Cu-terminals and connectors 0.75 - 1000 mm

Pin terminals 10 - 95 mm DIN 46230Data: electrolytic copper, tin plated, dimensions according to DIN 46230.mm 10 16 25 35 50 70 Cat. no. B10SR B16SR B25SR B35SR B50SR B70SR B95SR mm W 4,3 5,5 6,8 8,0 9,5 11,0 L1 12,0 13,0 15,0 20 20 23 23 L 22 26 34 41 45 55 55 Inner d 4,5 5,8 7,0 8,7 9,8 11,5 13,8 Pcs/ pack 100 100 100 100 100 100 100 Crimp tools page 9:3-6, 9:8-30

4

95

Through connectors for road lighting cables 6 - 16 mm SYSTEM 0616Data: electrolytic copper, tin plated, for solid and stranded conductors, included in SYSTEM 0616 for road lighting, see chapter 9. Crimp tool, see page 9:4.mm 6 6-10 10 10 10-16 16 16 Cat. no. KSE/S6M KSE/S6- KSE/S10 KSE/S10 KSE/S10M KSE/S10- KSE/S16 KSE/S16 KSE/S16M mm d 3,5 3,5-4,5 4,5 4,5 4,5-5,5 5,5 5,5 D 5,7 5,7-7,0 7,0 7,0 7,0-8,5 8,5 8,5 L 35 35 35 35 40 40 40 Pcs/ pack 100 100 100 100 100 100 100 Marking* I E/S6M II E/S10 I E/S6 II E/S10 II E/S10M III E/S16 II E/S10 III E/S16 III E/S16M

* Elpress logotype included in marking. ** I, II and III refers to die nests in dies MED616 to be used, see page 9:4.

Tube terminals for Ericsson Cables Excel type 10 - 16 mmData: electrolytic copper, tin plated, for PEX-insulated cables 10 and 16 mm Cu solid (Ericsson Excel type), to be applied non-tensioned.Cat. no. mm, bolt KRX 10-8 KRX 10-10 KRX 10-12 mm W 22 22 22 d 4,5 4,5 4,5 N 8,5 11,5 12,5 N1 17,5 18,5 19,5 L 68 72 74 Pcs/ pack 24 24 24 Crimp die id-no. 7 7 7 Crimp tools page 9:6

Two crimps are made when using the V500-, V611-, PV611- or T2600-systems, die TB7-20.

Connectors for Ericsson Cables Excel type 10 - 16 mmData: electrolytic copper, tin plated, for PEX-insulated cables 100 mm Cu solid (Excel), to be applied non-tensioned.Cat. no. mm KSX 10 mm d 4,5 D 7,0 L 65 Pcs/ pack 24 Marking* 10X 7 Crimp tool page 9:6

* Elpress logotype included. Two plus two crimps are made when using the V500-, V611-, PV611-, or T2600-Systems, die TB7-20.

4:20www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Cu-terminals and connectors 0.75 - 1000 mm

Branch connectors (C-sleeves) 6 - 300 mm! Data: electrolytic copper, for connecting and branching of earth conductors, in some cases

two adjacent compressions are necessary, see tools chapter 9.Elpress logotype is included in the marking. On the "reverse side" the C-sleeve is marked with the applicable wire area ranges.

Wire section area ranges Cat. no. C4 C5 C6 C89 C11-8 C11-9 C11 C13-8 C13-9 C13-11 C13 Side feed 10-6/10-6 16-10/16-10 25-16/25-16 25/10 25-50/25-50 16-50/35-50 70-50/35-25 70-50/50-35 70-50/70-50 95-70/35-25 95-70/50-35 95-70/70-50 95-70/95-70 120-95/35-25 120-95/50-35 120-95/70-50 120-95/95-70 120-95/120-95 150-120/50-35 150-120/95-70 150-120/150-120 185-150/35 185-150/50 185-150/70 185-150/95 185-150/120 185-150/150 185/185 240/35 240/50 240/70 240/95 240/120 240/150 240/185 240/240 300/150-120 300/300 Front feed 10/6 10/16-10 16/25-16 25-50/25-35 16-50/35 50/30-25 50/50-35 50/70-50 70/35-25 70/50-35 70/70-50 70/95-70 95/35-25 95/50-35 95/70-50 95/95-70 95/95 150-120/50-35 150-120/95-70 150-120/150-120 185-150/35 185-150/50 185-150/70 185-150/95 185-150/120 185-150/150 185/185 240/35 240/50 240/70 240/95 240/120 240/150 240/185 240/240 300/150-120 300/300 mm a 13,0 16,0 22 30 31 31 31 35 35 35 35 41 41 41 41 41 53 53 53 55 55 55 55 55 55 60 55 55 55 55 55 55 70 70 70 70 b 12,0 15,0 16,0 18 23 23 24 25 25 25 25 30 30 30 30 30 35 35 35 40 40 40 40 40 40 40 40 40 40 40 40 41 40 40 40 40 c 8,0 10,0 12,0 16/ 15,4 19,0 19,0 19,0 22 22 22 22 26 26 26 26 26 30 30 30 34 34 34 34 34 34 34 34 34 34 34 34 34 40 40 40 40 Pcs/ pack 100 100 100 50 50 50 50 50 50 50 50 25 25 25 25 25 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Die id-no. 4 5 6 8-9 11 11 11 13 13 13 13 15 15 15 15 15 16 16 16 18 18 18 18 18 18 18

Side feed

C15-8 C15-9 C15-11 C15-13 C15 C16-9 C16-13 C16

Front feed

C18-8 C18-9 C18-11 C18-13 C18-15 C18-16 C18 C21-8 C21-9 C21-11 C21-13 C21-15 C21-16 C21-18 C21 C23-16 C23

18 18 18 18 18 18 21 21 21 21

Certificate FM987 ISO 9001:2000

1:1www.sourceiec.com

Cu-terminals and connectors 0.75 - 1000 mm

Application table for C-sleeves (side feed only)Branch conductor, mm Through conductor, mm 6 C4 C4 10 C4 C4/C5 C5 C6 C5 C6 C6 C89 C89 C6 C6/C89 C89 C89 C11-8 C11-8 C13-8 C15-8 C15-8 C89 C89 C89 C11-8/C11-9 C118/C11-9 C13-8 C15-8/C15-9 C15-8/C15-9 C16-9 C18-8 C21-8 C89 C89 C11-9/C11 C11-9/C11 C13-11 C13-11 C15-9/C15-11 C15-9/C15-11 C16-9 C16-9 C18-9 C18-9 C21-9 16 25 35 50

Side feed

6 10 16 25 35 50 50 70 70 95 95 120 120 150 150 185 240 300

Branch conductor, mm Through conductor mm 6 10 16 25 35 35 50 50 70 70 95 95 120 120 150 150 185 240 300 Note - Open choice is marked with slash "/" - When chosing between e.g. C11-9 and C11, use primarily C11 - The smaller sleeve is preferred, e.g. C8 in stead of C9, etc. C11 C11 C13-11/C13 C13-11/C13 C15-11/C15-13 C15-11/C15-13 C16-13 C16-13 C18-11 C18-11 C21-11 C13 C13 C15-3/C15 C15-13/C15 C16-13 C16-13 C18-13 C18-13 C21-13 C15 C15 C16 C16 C18-15 C18-15 C21-15 C16 C16 C18-16 C18-16 C21-16 C23-16 C18 C21-18 C21 C23 70 95 120 150 185 240 300

Certificate FM987 ISO 9001:2000

1:1www.sourceiec.com

Al and AlCu terminals and connectors 16 - 1200 mm

Terminals and connectorsElpress terminals and connectors are made from pure aluminium 99.7% and, in case of bi-metal types, also from electrolytic copper. The standard range size is 16 to 1200 mm but a variety of customer specified types also exists. The Elpress Crimp System fits compacted/un-compacted stranded as well as solid Al conductors in accordance with IEC 60228. Note that in case of solid conductors one area step down is used as marked on the barrel. In case of sectorshaped conductors, pre-rounding is required and performed with tools within the Crimp System. This makes it possible to crimp the terminal in such a position that twisting is minimised when connecting to the bus bar or apparatus. Two indents are always made in the order shown in the picture below.

TERMINALS: Markings on Al and AlCu terminals

All Al or AlCu typesAl terminals type AK are mainly used for connection to Al bus bars, apparatus terminals or such. Bi-metal terminals type AKK are mainly used for connection to Cu busbars, apparatus terminals or such. Al connectors type AS are used to connect two Al conductors, also of different sizes. Bi-metal connectors type AKS are used to connect an Al and a Cu conductor also of different sizes. Bi-metal pin connectors type AKP are used to connect Al conductors to mechanical clamp type connections for round Cu pins.

Barrel marking, example: ALU185-R18-P32 (Elpress logotype) T2 SOLID 240ALU185 = Al-conductor, mm R18 = id-no. for punch and matrix for pre-rounding P32 = id-no. for punch and matrix for crimping T2 = Finnish temperature class SOLID 240 = suitable size on solid conductor

5

Palm marking: (Elpress logotype) 16 = M-screw sizeTHROUGH CONNECTORS: Markings on Al and AlCu connectors

Copper side of AlCu type Example: Cu240 - 30 (Elpress logotype)Cu240 = Cu conductor, mm 30 = id-no. for hexagonal crimp die

Al connector or Al side of AlCu connector Example: ALU300-R21-P36 (Elpress logotype) T2ALU300 = Al conductor, mm Crimp sequence when making indent crimping on aluminium. R21 = id-no. of punch and matrix for pre-rounding P36 = id-no. of punch and matrix for crimping T2 = Finnish temperature class

Marking of Al and AlCu terminalsElpress System for marking of Al and AlCu terminals and connectors shows the stranded and solid metric conductor size and reference to the id-numbers of the appropriate Elpress pre-rounding and crimp tools. Do not use other crimp tools! The T2-mark is a reference to an earlier Finnish standard. On bi-metal connectors there is also a tool id-reference to the hexagonal die to be used for the Cu-crimp.

Palm holes to ISO 273Screw dimension M3 M4 M5 M6 M8 M 10 M 12 M 16 M 20 M 24 Palm hole tol H13 ( mm) 3,2 4,3 5,3 6,4 8,4 10,5 13 17 21 25

5:2www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Al and AlCu terminals and connectors 16 - 1200 mm

AlCu, bi-metallic terminals 16 - 1200 mmused primarily to terminate Al-conductors to Cu appliance studs, Cu bus bars, etc. two adjacent crimps are necessary - crimp sequence , see pictureCat. no. stranded, mm AKK 16-8 AKK 25-8 AKK 25-12 AKK 35-8 AKK 50-8 AKK 50-10 AKK 50-12 AKK 70-8 AKK 70-10 AKK 70-12 AKK 95-8 AKK 95-10 AKK 95-12 AKK 95-16 AKK 120-10 AKK 120-12 AKK 120-16 AKK 150-10 AKK 150-12 AKK 150-16 Solid mm W d 5,9 N 8,5 8,5 11,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 18,5 18,5 18,5 18,5 18,5 18,5 18,5 18,5 18,5 26 26 70* 70* 21 21 70* 70* 70* 70* 70* 75* 70* 75* 75* 21 21 N1 10,0 10,0 15,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 18,5 18,5 18,5 18,5 18,5 18,5 18,5 18,5 18,5 29 29 L 66 66 75 89 89 89 89 89 89 89 114 114 114 115 114 114 114 114 114 114 116 116 116 116 116 116 155 155 155 155 155 155 155 155 155 224 224 239 239 174 174 202 211 239 239 263 275 263 275 310 9:36 3 3 3 Pcs/ pack 48 48 24 24 24 24 24 24 24 24 24 24 24 24 12 12 12 12 12 12 12 12 12 12 12 12 6 6 6 6 6 6 6 6 6 3 3 4 4 2 2 5 5 2 2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 Crimp tools page 9:7 9:11 9:16 9:27-33 Note

25 (16) 16,0 35 35 50 70 70 70 95 95 95 120 120 120 120 150 150 150 185 185 185 240 240 240

16,0 6,8 22 10,0 25 25 25 25 25 25 25 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 37 37 37 37 37 37 37 37 37 55 55 55 70 42 42 42 70 55 70 62 75 62 75 75 8,5 9,6 9,6 9,6 11,3 11,3 11,3 12,5 12,5 12,5 12,5 14,0 14,0 14,0 15,8 15,8 15,8 17,6 17,6 17,6 19,8 19,8 19,8 22 22 22 20 20 20 25 25 25 28 28 28 28 28 28 28 28 32 32 36 36 40 40 44

5

Crimp sequence.

AKK 185-10 AKK 185-12 AKK 185-16 AKK 240-10 AKK 240-12 AKK 240-16 AKK 300-12 AKK 300-16 AKK 300-20 AKK 300-12 Solid AKK 300-16 Solid AKK 300-20 Solid AKK 400-12 AKK 400-16 AKK 400-20 AKK 500A-16 AKK 500A-20 AKK 500A/1 AKK 500A/2 AKK 500B-16 AKK 500B-20 AKK 500B-1 AKK 500B-2 AKK 630A/1 AKK 630A/2

Note 1 Stranded, compacted conductor 2 Unholed palm 3 For solid conductors only 4 Outer barrel diam. 52 mm. 5 Outer barrel diam. 44 mm.

AKK 800/1 AKK 800/2 AKK 1000/1 AKK 1000/2 AKK 1200* the full palm length

Certificate FM20987 ISO 9001:2000

5:7www.sourceiec.com

Al and AlCu terminals and connectors 16 - 1200 mm

AlCu bi-metallic pin terminals, 16 - 300 mmused to connect Al conductors to mechanical clamp type connections for round Cu pins. two adjacent crimps are necessary - crimp sequence, see pictureCat. no. stranded, mm AKP 16 AKP 25 AKP 35 AKP 50 AKP 70 AKP 95 AKP 120 AKP 150 AKP 185 Solid mm 25 (16) 35 50 70 95 120 150 185 240 mm e 6,0 6,0 9,0 9,0 9,0 12,0 12,0 12,0 14,0 14,0 16,0 d 5,9 6,8 8,5 9,6 11,3 12,5 14,0 15,8 17,6 19,8 22 D 13,0 13,0 20 20 20 25 25 25 32 32 36 L1 25 25 25 35 35 35 40 40 45 45 50 L 56 56 78 88 88 103 108 108 113 113 143 Pcs/ pack 48 48 24 24 24 24 24 24 12 12 9 Crimp tools page 9:7 9:11 9:16 9:27-33 9:7

5

AKP 240 AKP 300

Crimp sequence.

Transition connectors for Al conductors 16 - 95 mm to Cu solid conductors 10 mmadapter connector from stranded Al-conductor to solid Cu-conductor 10 mm2 (e.g. Excel, Excelett) two crimps are necessary for both Al and Cu, crimp sequence see picture (equal order for Cu)Cat. no., mm, Al-Cu AKS 16-10S AKS 25-10S AKS 35-10S AKS 50-10S AKS 70-10S AKS 95-10S Note 1. Make two crimps also on the Cu-side. Solid Al mm 25 (16) 35 50 70 95 120 mm d 5,9 6,8 8,5 9,6 11,3 12,5 d1 4,5 4,5 4,5 4,5 4,5 4,5 L 64 64 86 86 86 101 Pcs/ pack 48 48 48 24 24 24 9:7 9:7 Crimp tools page 9:11-33 Note 1 1 1 1 1 1

Crimp sequence.

5:8www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Al and AlCu terminals and connectors 16 - 1200 mm

AlCu bimetallic through connectors 16 - 400 mmconnect Al-conductors to Cu-conductors stranded/solid Al-conductors, stranded/flexible Cu conductor two adjacent crimps for Al, see picture; normally one for Cu, see note when crimping the Cu-part, place the dies between the circular groove on the Cu-barrel and the edgeCat. no., mm, Al-Cu AKS 16-10 AKS 25-10 AKS 25-16 AKS 35-10 AKS 35-16 AKS 35-25 AKS 50-10 AKS 50-16 AKS 50-25 AKS 50-35 AKS 50-50 AKS 70-35 AKS 70-50 AKS 70-70 AKS 95-10 AKS 95-16 AKS 95-25 AKS 95-35 AKS 95-50 AKS 95-70 AKS 95-95 AKS 120-50 AKS 120-70 AKS 120-95 AKS 120-120 AKS 150-25 AKS 150-35 AKS 150-50 AKS 150-70 AKS 150-95 AKS 150-120 AKS 150-150 AKS 185-95 AKS 185-120 AKS 185-150 AKS 185-185 AKS 240-35 AKS 240-50 AKS 240-70 AKS 240-95 AKS 240-120 AKS 240-150 AKS 240-185 AKS 240-240A AKS 300-150 AKS 300-185 AKS 300-240A AKS 400-150 AKS 400-185 AKS 400-240A AKS 400-300A Solid Al mm 25 (16) 35 35 50 50 50 70 70 70 70 70 95 95 95 120 120 120 120 120 120 120 150 150 150 150 185 185 185 185 185 185 185 240 240 240 240 mm d 5,9 6,8 6,8 8,5 8,5 8,5 9,6 9,6 9,6 9,6 9,6 11,3 11,3 11,3 12,5 12,5 12,5 12,5 12,5 12,5 12,5 14,0 14,0 14,0 14,0 15,8 15,8 15,8 15,8 15,8 15,8 15,8 17,6 17,6 17,6 17,6 19,8 19,8 19,8 19,8 19,8 19,8 19,8 19,8 22 22 22 25 25 25 25 d1 5,0 5,0 6,0 5,0 6,0 8,0 5,0 6,0 8,0 9,0 11,0 9,0 11,0 13,0 5,0 6,0 8,0 9,0 11,0 13,0 15,0 11,0 13,0 15,0 17,0 8,0 9,0 11,0 13,0 15,0 17,0 19,0 15,0 17,0 19,0 21 9,0 11,0 13,0 15,0 17,0 19,0 21 22,5 19,0 21 22,5 19,0 21 22,5 24,5 L 46 46 46 66 66 69 66 66 69 71 76 71 76 78 81 81 84 86 91 93 94 91 93 94 98 84 86 91 93 94 99 99 94 99 100 100 87 91 94 94 99 100 100 100 124 124 125 124 124 124 125 Pcs/ pack 48 48 48 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 12 12 12 12 12 12 12 12 12 12 12 12 9 9 9 6 6 6 6 9:7 Crimp tools page 9:11 9:16 9:27-33

5

Crimp sequence.

Certificate FM20987 ISO 9001:2000

5:9www.sourceiec.com

Al and AlCu terminals and connectors 16 - 1200 mm

Terminals and connectorsElpress terminals and connectors are made from pure aluminium 99.7% and, in case of bi-metal types, also from electrolytic copper. The standard range size is 16 to 1200 mm but a variety of customer specified types also exists. The Elpress Crimp System fits compacted/un-compacted stranded as well as solid Al conductors in accordance with IEC 60228. Note that in case of solid conductors one area step down is used as marked on the barrel. In case of sectorshaped conductors, pre-rounding is required and performed with tools within the Crimp System. This makes it possible to crimp the terminal in such a position that twisting is minimised when connecting to the bus bar or apparatus. Two indents are always made in the order shown in the picture below.

TERMINALS: Markings on Al and AlCu terminals

All Al or AlCu typesAl terminals type AK are mainly used for connection to Al bus bars, apparatus terminals or such. Bi-metal terminals type AKK are mainly used for connection to Cu busbars, apparatus terminals or such. Al connectors type AS are used to connect two Al conductors, also of different sizes. Bi-metal connectors type AKS are used to connect an Al and a Cu conductor also of different sizes. Bi-metal pin connectors type AKP are used to connect Al conductors to mechanical clamp type connections for round Cu pins.

Barrel marking, example: ALU185-R18-P32 (Elpress logotype) T2 SOLID 240ALU185 = Al-conductor, mm R18 = id-no. for punch and matrix for pre-rounding P32 = id-no. for punch and matrix for crimping T2 = Finnish temperature class SOLID 240 = suitable size on solid conductor

5

Palm marking: (Elpress logotype) 16 = M-screw sizeTHROUGH CONNECTORS: Markings on Al and AlCu connectors

Copper side of AlCu type Example: Cu240 - 30 (Elpress logotype)Cu240 = Cu conductor, mm 30 = id-no. for hexagonal crimp die

Al connector or Al side of AlCu connector Example: ALU300-R21-P36 (Elpress logotype) T2ALU300 = Al conductor, mm Crimp sequence when making indent crimping on aluminium. R21 = id-no. of punch and matrix for pre-rounding P36 = id-no. of punch and matrix for crimping T2 = Finnish temperature class

Marking of Al and AlCu terminalsElpress System for marking of Al and AlCu terminals and connectors shows the stranded and solid metric conductor size and reference to the id-numbers of the appropriate Elpress pre-rounding and crimp tools. Do not use other crimp tools! The T2-mark is a reference to an earlier Finnish standard. On bi-metal connectors there is also a tool id-reference to the hexagonal die to be used for the Cu-crimp.

Palm holes to ISO 273Screw dimension M3 M4 M5 M6 M8 M 10 M 12 M 16 M 20 M 24 Palm hole tol H13 ( mm) 3,2 4,3 5,3 6,4 8,4 10,5 13 17 21 25

5:2www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Al and AlCu terminals and connectors 16 - 1200 mm

Al terminals 16 - 1200 mmused to terminate Al-conductors to Al busbars two adjacent crimps are necessary - crimp sequence see picture other designs, see page 5:5Cat. no. stranded, mm AK 16-6 AK16-8 AK 25-6 AK 25-8 AK 35-6 AK 35-8 AK 50-8 AK 50-10 AK 50-12 AK 70-8 AK 70-10 AK 70-12 AK 95-8 AK 95-10 AK 95-12 AK 120-10 AK 120-12 AK 150-10 AK 150-12 AK 150-16 Solid 25(16) 25 (16) 35 35 50 50 70 70 70 95 95 95 120 120 120 150 150 185 185 185 240 240 240 mm W 16,0 16,0 16,0 16,0 22 22 22 22 27 22 22 27 27 27 27 27 27 27 27 35 35 35 35 35 35 41 41 41 41 41 41 41 41 55 55 55 70 44 44 44 70 55 70 60 75 60 75 75 d 5,9 5,9 6,8 6,8 8,5 8,5 9,6 9,6 9,6 11,3 11,3 11,3 12,5 12,5 12,5 14,0 14,0 15,8 15,8 15,8 17,6 17,6 17,6 19,8 19,8 20 20 22 22 22 25 25 25 28 28 28 28 28 28 28 28 32 32 36 36 40 40 44 N 8,5 8,5 8,5 8,5 11,0 11,0 11,0 11,0 14,0 11,0 11,0 14,0 14,0 14,0 14,0 14,0 14,0 14,0 14,0 21 16,0 16,0 16,0 16,0 16,0 18,0 18,0 18,0 18,0 20 18,0 18,0 20 26 26 80* 80* 22 22 80* 80* 80* 80* 80* 80 80* 80* 80* 22 22 N1 9,0 9,0 9,0 9,0 14,0 14,0 14,0 14,0 15,0 14,0 14,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 23 19,0 19,0 19,0 19,0 19,0 25 25 25 25 23 25 25 23 29 29 L 57 57 57 57 85 85 85 85 90 85 85 90 104 104 104 104 104 104 104 119 112 112 112 112 112 155 155 155 155 155 155 155 155 225 225 250 250 174 174 210 210 250 250 267 275 267 375 291 Pcs/ pack 48 48 48 48 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 12 12 12 12 12 12 6 6 6 6 6 6 6 6 3 3 3 3 3 3 3 3 3 3 1 1 1 1 1 4 4 2,4 2,4 5 5 5 5 1,2 1,2 1,2 1,2 1,2 1,2 1,2 9:36 3 3 Note Crimp tools page 9:7 9:11 9:16 9:27-33

5

Crimp sequence.

AK 185-10 AK 185-12 AK 185-16 AK 240-12 AK 240-16 AK 300-12 SOLID AK 300-16 SOLID AK 300-12 AK 300-16 AK 300-20 AK 400-12 AK 400-16 AK 400-20 AK 500A-16 AK 500A-20 AK 500A/1 AK 500A/2 AK 500B-16 AK 500B-20 AK 500B-1 AK 500B-2 AK 630A/1 AK 630A/2

Note 1 Stranded, compacted conductor 2 Unholed palm 3 For solid conductors only 4 Outer barrel diam. 52 mm. 5 Outer barrel diam. 44 mm.

AK 800/1 AK 800/2 AK 1000/1 AK 1000/2 AK 1200

* corresponds to the full palm length. ** Outer diameter 52 mm. Also available with outer diameter 44 mm - see AK500B-xx.

Certificate FM20987 ISO 9001:2000

5:3www.sourceiec.com

Al and AlCu terminals and connectors 16 - 1200 mm

Through connectors with partition 16 - 1200 mmused mainly for connecting two Al-conductors of the same size to each other two crimps on each side are necessary, crimp sequence see picture partition in the middle to prevent fluid flowCat. no. stranded, mm AS 16 AS 25 AS 35 AS 50 AS 70 AS 95 AS 120 AS 150 AS 185 AS 240 AS 300 SOLID AS 300 AS 400 AS 500A AS 500B AS 630A /1 AS 630 /1 AS 800 /1 AS 1000 /1 AS 1200 Solid mm 25 (+16) 35 50 70 95 120 150 185 240 300 mm d 5,9 6,8 8,5 9,6 11,3 12,5 14,0 15,8 17,6 19,8 20 22 25 28 28 32 32 36 40 44 D 13,0 13,0 20 20 20 25 25 25 32 32 36 36 40 52 44 52 60 60 60 70 L 67 67 100 100 100 130 130 130 131 131 179 179 179 250 184 250 288 288 288 320 9:36 Pcs/ pack 48 48 24 24 24 12 12 12 9 9 6 3 3 3 3 4 5 1 1 1 1 1 3 Crimp tools page 9:7 9:11 9:16 9:27-33 9:7 Note

5

Crimp sequence.

If other combinations are needed, contact Elpress.

Note 1 2 3 Stranded, compacted conductor 4 Unholed palm For solid conductors only 5 Barrel outer diam. 52 mm. Barrel outer diam. 44 mm.

5:4www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Al and AlCu terminals and connectors 16 - 1200 mm

Through connectors without partition 50 - 240 mmused mainly for connecting two Al-conductors of the same size to each other two crimps on each side are necessary, crimp sequence see picture no partition in the middleCat. no. stranded, mm AS 50H AS 70H AS 95H AS 120H AS 150H AS 185H AS 240H Solid mm 70 95 120 150 185 240 mm d 9,6 11,3 12,5 14,0 15,8 17,6 19,8 D 20 20 25 25 25 32 32 L 100 100 130 130 130 131 131 Pcs/ pack 24 24 12 12 12 9 9 Crimp tools page 9:11 9:16-33

5

Crimp sequence.

Other designs of Al and AlCu terminals and connectorsIn cases where other hole patterns, palm sizes, assembly angles, etc. are needed, a broad variety of customer specified items may be produced. Some examples are indicated here: AKK500A/2-16-12x4-35 resp. AK185-14x2-40.

Certificate FM20987 ISO 9001:2000

5:5www.sourceiec.com

Al and AlCu terminals and connectors 16 - 1200 mm

Through connectors with partition and for different areas 16 - 400 mmused mainly for connecting two Al-conductors of different sizes to each other two crimps on each side are necessary, crimp sequence see picture partition in the middle to prevent fluid flowCat. no. stranded, mm AS 25-16 AS 35-25 AS 50-25 AS 50-35 AS 70-50 AS 95-25 AS 95-35 AS 95-50 AS 95-70 AS 120-95 AS 150-50 AS 150-70 AS 150-95 AS 150-120 AS 185-95 AS 185-150 AS 240-95 AS 240-120 AS 240 -150 AS 240-185 AS 300-240 Solid mm 35-25 50-35 70-35 70-50 95-70 120-35 120-50 120-70 120-95 150-120 185-70 185-95 185-120 185-150 240-120 240-185 -120 -150 -185 -240 mm L 67 85 85 100 100 101 116 116 116 130 116 116 130 130 132 132 132 132 132 131 156 179 d1 5,9 6,8 6,8 8,5 9,6 6,8 8,5 9,6 11,3 12,5 9,6 11,3 12,5 14,0 12,5 15,8 12,5 14,0 15,8 17,6 19,8 22 D1 13,0 13,0 13,0 20 20 13,0 20 20 20 25 20 20 25 25 25 25 25 25 25 32 32 36 d 6,8 8,5 9,6 9,6 11,3 12,5 12,5 12,5 12,5 14 15,8 15,8 15,8 15,8 17,6 17,6 19,8 19,8 19,8 19,8 22 25 D 13,0 20 20 20 20 25 25 25 25 25 25 25 25 25 32 32 32 32 32 32 36 40 Pcs/ pack 48 24 24 24 24 24 24 24 24 12 12 24 12 12 12 12 12 12 12 12 6 3 9:11 Crimp tools page 9:16 9:27-33

5

Crimp sequence.

AS 400-300

Other measures, see corresponding connector on previous pages. If other combinations are needed, contact Elpress.

5:6www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Al and AlCu terminals and connectors 16 - 1200 mm

Terminals and connectorsElpress terminals and connectors are made from pure aluminium 99.7% and, in case of bi-metal types, also from electrolytic copper. The standard range size is 16 to 1200 mm but a variety of customer specified types also exists. The Elpress Crimp System fits compacted/un-compacted stranded as well as solid Al conductors in accordance with IEC 60228. Note that in case of solid conductors one area step down is used as marked on the barrel. In case of sectorshaped conductors, pre-rounding is required and performed with tools within the Crimp System. This makes it possible to crimp the terminal in such a position that twisting is minimised when connecting to the bus bar or apparatus. Two indents are always made in the order shown in the picture below.

TERMINALS: Markings on Al and AlCu terminals

All Al or AlCu typesAl terminals type AK are mainly used for connection to Al bus bars, apparatus terminals or such. Bi-metal terminals type AKK are mainly used for connection to Cu busbars, apparatus terminals or such. Al connectors type AS are used to connect two Al conductors, also of different sizes. Bi-metal connectors type AKS are used to connect an Al and a Cu conductor also of different sizes. Bi-metal pin connectors type AKP are used to connect Al conductors to mechanical clamp type connections for round Cu pins.

Barrel marking, example: ALU185-R18-P32 (Elpress logotype) T2 SOLID 240ALU185 = Al-conductor, mm R18 = id-no. for punch and matrix for pre-rounding P32 = id-no. for punch and matrix for crimping T2 = Finnish temperature class SOLID 240 = suitable size on solid conductor

5

Palm marking: (Elpress logotype) 16 = M-screw sizeTHROUGH CONNECTORS: Markings on Al and AlCu connectors

Copper side of AlCu type Example: Cu240 - 30 (Elpress logotype)Cu240 = Cu conductor, mm 30 = id-no. for hexagonal crimp die

Al connector or Al side of AlCu connector Example: ALU300-R21-P36 (Elpress logotype) T2ALU300 = Al conductor, mm Crimp sequence when making indent crimping on aluminium. R21 = id-no. of punch and matrix for pre-rounding P36 = id-no. of punch and matrix for crimping T2 = Finnish temperature class

Marking of Al and AlCu terminalsElpress System for marking of Al and AlCu terminals and connectors shows the stranded and solid metric conductor size and reference to the id-numbers of the appropriate Elpress pre-rounding and crimp tools. Do not use other crimp tools! The T2-mark is a reference to an earlier Finnish standard. On bi-metal connectors there is also a tool id-reference to the hexagonal die to be used for the Cu-crimp.

Palm holes to ISO 273Screw dimension M3 M4 M5 M6 M8 M 10 M 12 M 16 M 20 M 24 Palm hole tol H13 ( mm) 3,2 4,3 5,3 6,4 8,4 10,5 13 17 21 25

5:2www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Al and AlCu terminals and connectors 16 - 1200 mm

Al terminals 16 - 1200 mmused to terminate Al-conductors to Al busbars two adjacent crimps are necessary - crimp sequence see picture other designs, see page 5:5Cat. no. stranded, mm AK 16-6 AK16-8 AK 25-6 AK 25-8 AK 35-6 AK 35-8 AK 50-8 AK 50-10 AK 50-12 AK 70-8 AK 70-10 AK 70-12 AK 95-8 AK 95-10 AK 95-12 AK 120-10 AK 120-12 AK 150-10 AK 150-12 AK 150-16 Solid 25(16) 25 (16) 35 35 50 50 70 70 70 95 95 95 120 120 120 150 150 185 185 185 240 240 240 mm W 16,0 16,0 16,0 16,0 22 22 22 22 27 22 22 27 27 27 27 27 27 27 27 35 35 35 35 35 35 41 41 41 41 41 41 41 41 55 55 55 70 44 44 44 70 55 70 60 75 60 75 75 d 5,9 5,9 6,8 6,8 8,5 8,5 9,6 9,6 9,6 11,3 11,3 11,3 12,5 12,5 12,5 14,0 14,0 15,8 15,8 15,8 17,6 17,6 17,6 19,8 19,8 20 20 22 22 22 25 25 25 28 28 28 28 28 28 28 28 32 32 36 36 40 40 44 N 8,5 8,5 8,5 8,5 11,0 11,0 11,0 11,0 14,0 11,0 11,0 14,0 14,0 14,0 14,0 14,0 14,0 14,0 14,0 21 16,0 16,0 16,0 16,0 16,0 18,0 18,0 18,0 18,0 20 18,0 18,0 20 26 26 80* 80* 22 22 80* 80* 80* 80* 80* 80 80* 80* 80* 22 22 N1 9,0 9,0 9,0 9,0 14,0 14,0 14,0 14,0 15,0 14,0 14,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 23 19,0 19,0 19,0 19,0 19,0 25 25 25 25 23 25 25 23 29 29 L 57 57 57 57 85 85 85 85 90 85 85 90 104 104 104 104 104 104 104 119 112 112 112 112 112 155 155 155 155 155 155 155 155 225 225 250 250 174 174 210 210 250 250 267 275 267 375 291 Pcs/ pack 48 48 48 48 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 12 12 12 12 12 12 6 6 6 6 6 6 6 6 3 3 3 3 3 3 3 3 3 3 1 1 1 1 1 4 4 2,4 2,4 5 5 5 5 1,2 1,2 1,2 1,2 1,2 1,2 1,2 9:36 3 3 Note Crimp tools page 9:7 9:11 9:16 9:27-33

5

Crimp sequence.

AK 185-10 AK 185-12 AK 185-16 AK 240-12 AK 240-16 AK 300-12 SOLID AK 300-16 SOLID AK 300-12 AK 300-16 AK 300-20 AK 400-12 AK 400-16 AK 400-20 AK 500A-16 AK 500A-20 AK 500A/1 AK 500A/2 AK 500B-16 AK 500B-20 AK 500B-1 AK 500B-2 AK 630A/1 AK 630A/2

Note 1 Stranded, compacted conductor 2 Unholed palm 3 For solid conductors only 4 Outer barrel diam. 52 mm. 5 Outer barrel diam. 44 mm.

AK 800/1 AK 800/2 AK 1000/1 AK 1000/2 AK 1200

* corresponds to the full palm length. ** Outer diameter 52 mm. Also available with outer diameter 44 mm - see AK500B-xx.

Certificate FM20987 ISO 9001:2000

5:3www.sourceiec.com

Al and AlCu terminals and connectors 16 - 1200 mm

Through connectors with partition 16 - 1200 mmused mainly for connecting two Al-conductors of the same size to each other two crimps on each side are necessary, crimp sequence see picture partition in the middle to prevent fluid flowCat. no. stranded, mm AS 16 AS 25 AS 35 AS 50 AS 70 AS 95 AS 120 AS 150 AS 185 AS 240 AS 300 SOLID AS 300 AS 400 AS 500A AS 500B AS 630A /1 AS 630 /1 AS 800 /1 AS 1000 /1 AS 1200 Solid mm 25 (+16) 35 50 70 95 120 150 185 240 300 mm d 5,9 6,8 8,5 9,6 11,3 12,5 14,0 15,8 17,6 19,8 20 22 25 28 28 32 32 36 40 44 D 13,0 13,0 20 20 20 25 25 25 32 32 36 36 40 52 44 52 60 60 60 70 L 67 67 100 100 100 130 130 130 131 131 179 179 179 250 184 250 288 288 288 320 9:36 Pcs/ pack 48 48 24 24 24 12 12 12 9 9 6 3 3 3 3 4 5 1 1 1 1 1 3 Crimp tools page 9:7 9:11 9:16 9:27-33 9:7 Note

5

Crimp sequence.

If other combinations are needed, contact Elpress.

Note 1 2 3 Stranded, compacted conductor 4 Unholed palm For solid conductors only 5 Barrel outer diam. 52 mm. Barrel outer diam. 44 mm.

5:4www.sourceiec.com

Certificate FM20987 ISO 9001:2000

Al and AlCu terminals and connectors 16 - 1200 mm

Through connectors without partition 50 - 240 mmused mainly for connecting two Al-conductors of the same size to each other two crimps on each side are necessary, crimp sequence see picture no partition in the middleCat. no. stranded, mm AS 50H AS 70H AS 95H AS 120H AS 150H AS 185H AS 240H Solid mm 70 95 120 150 185 240 mm d 9,6 11,3 12,5 14,0 15,8 17,6 19,8 D 20 20 25 25 25 32 32 L 100 100 130 130 130 131 131 Pcs/ pack 24 24 12 12 12 9 9 Crimp tools page 9:11 9:16-33

5

Crimp sequence.

Other designs of Al and AlCu terminals and connectors