eljintek

85

description

catalog_eljintek

Transcript of eljintek

ELJINTEK, INC.

Adapter Information Technology Equipment Single Output 2013/02/25 6W Wall mount (Energy star V) GPSU06 / P2

15W Wall mount (Energy star V) GPSU15 / P4

15W Desktop (Energy star V) GPSU15 / P6

18W Wall mount (Energy star V) GPSU18 / P8

18W Wall mount Interchangeable (Energy star V) GPSU18 / P10 18W Desktop (Energy star V) GPSU18 / P12 30W Desktop (Energy star V) GPSU30 / P14 40W Desktop (Energy star V) GPSU40 / P16

50W Desktop (Energy star V) A2-50 / P18

60~65W Desktop (Energy star V) A2-60; A2-65 / P20 66W Desktop PSU66 / P22

70W Desktop (Energy star V) GPSU70 / P24

Adapter Information Technology Equipment Dual or Triple Output 25W Desktop PSU25 / P26

50W Desktop PSU50 / P28

Adapter Medical Equipment 6W Wall mount (Energy star V) GMPU06 / P30

18W Wall mount (Energy star V) GMPU18 / P32 18W Wall mount interchangeable (Energy star V) GMPU18 / P34 18W Desktop (Energy star V) GMPU18 / P36 30W Desktop MPU30 / P38 50W Desktop MPU50 / P40

70W Desktop (Energy star V) GMPU70 / P42

Battery Charger 6W Wall mount GPSU06X-CC / P44 15W Wall mount GPSU15X-CC / P46 15W Desktop GPSU15X-CC / P48 30W Desktop GPSU30X-CC / P50

OPEN FRAME 15W (Energy star V) GPSO15 / P52 30W (Energy star V) GPSO30 / P54 40W (Energy star V) GPSO40 / 56

LED LEO15W LEO15 / P58 LEO40W LEO40 / P60

LE41 LE41 / P62

LE61 LE61 / P64

USB Charger UL / 5W USB Charger (Energy star V) GUSB05 / P66

TUV / 5W USB Charger (Energy star V) GUSB05E / P67

UL / 10.5W USB Charger (Energy star V) GUSB12 / P68

TUV / 10.5W USB Charger (Energy star V) GUSB12E / P69

In Car DC to DC USB

5V 500mA USB PSD03 / P70

In Car DC to DC Isolation

18W (Input:36~72VDC) PSD18 / P71

18W (Input:11~26VDC) PSD25 / P72 36W (Input:11~26VDC) PSD40 / P73

In Car DC to DC Non Isolation 8W (Input:11~15VDC) PSD12 / P74 25W (Input:11~26VDC) PSD25 / P75

40W (Input:11~26VDC) PSD40 / P76 60W (Input:11~15VDC) PSD60 / P77

In Car Power Extension Adapter With USB 12W-24VDC Dual standard USB connector EJ13-123 / P78 12VDC standard USB connector EJ13-149 / P79

12VDC Dual standard USB connector EJ13-175 / P80

CONNECTOR (DC PLUG)LIST P.81

GPSU06 6W Wall mount series (ENERGY STAR V) Plug-in power supply Features:

Universal input voltage No load power consumption: <0.3W Meet ENERGY STAR V for 5~48VDC Single output Pass LPS Optional output connectors Short circuit protection High efficiency & reliability Outputs are available at request Compact package One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: GPSU06 series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.2A Max. Leakage current 0.25mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating Chart Over voltage protection Yes, Protected by Zener diode Over current protection Yes. Auto-recovery

Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection Yes. Hiccup mode ; Auto- recovery Temperature coefficient All output±0.04%/ maximum

Transient response Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature 0~+40.See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at+40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up/Hold up/Rise time Typical: 3000mS / 16mS / 50mS at full load. Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Or see rating chart Insulation resistance 50Mohm minimum from input to output Inrush current 30 AMPS@115 VAC;60AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11

(B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003 Safety requirements (A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1 Warranty 1year

<2>

GPSU06 6W Wall mount series (ENERGY STAR V)

X=U American type (FIG1) or E European type (FIG2) or S 3pin Australian type (FIG3) or SA 2pin Australian type (FIG4) or BS UK type (FIG5)

Model name Output

Voltage(VDC) Output

Current(A) Max .Output Power (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation

(%)

Avg. EFF (%) 25,50,75,100%

load

No load Power Consumption(W)

Measured at the

output of GPSU06X-0 3~5 1.33~0.80 4 50 ±1 ±5.5 55 <0.3 3.3 GPSU06X-1 5~6 1.00~0.80 5 50 ±0.5 ±5 68.19 <0.3 5 GPSU06X-1-1 6~8 1.00~0.75 6 80 ±0.5 ±5 74 <0.3 7.5 GPSU06X-2 8~11 0.75~0.54 6 80 ±0.5 ±5 74 <0.3 9 GPSU06X-3 11~13 0.54~0.46 6 100 ±0.5 ±3 74 <0.3 12 GPSU06X-4 13~16 0.46~0.37 6 120 ±0.5 ±3 74 <0.3 15 GPSU06X-5 16~21 0.37~0.28 6 150 ±0.5 ±3 74 <0.3 18 GPSU06X-6 21~27 0.28~0.20 6 180 ±0.5 ±2 74 <0.3 24 GPSU06X-7 27~33 0.20~0.18 6 200 ±0.5 ±2 74 <0.3 28 GPSU06X-8 33~48 0.18~0.12 6 200 ±0.5 ±2 74 <0.3 48 Note: 1. Weight: Approx 70~100g 2. Optional output connectors (see page 81) 3. ENERGY STAR V Standard Output cable: 20AWG UL2468 6FT

<3>

GPSU15 15W Wall mount series (ENERGY STAR V) Plug-in power supply Features:

Universal input voltage No load power consumption<0.3W Meet ENERGY STAR V for 5~48VDC Single output Pass LPS Optional output connectors Short circuit protection High efficiency & reliability Outputs are available at request Compact package One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: GPSU15 series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.5A Max. Leakage current 0.25mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating Chart Over voltage protection Yes, Protected by Zener diode Over current protection Yes. Auto-recovery

Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection Yes. Hiccup mode ; Auto-recovery Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40.See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up / Hold up / Rise time Typical: 3000mS / 16mS / 50mS at full load. Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Or see rating chat Insulation resistance 50Mohm. minimum from input to output Inrush current 40 AMPS@115 VAC ; 60AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11

(B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003 Safety requirements (A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1 Warranty 1year

<4>

GPSU15 15W Wall mount series (ENERGY STAR V)

X=U American type (FIG1) or E European type (FIG2) or S 3pin Australian type (FIG3) or SA 2pin Australian type (FIG4) or BS UK type (FIG5)

Model name Output

Voltage(VDC) Output

Current(A)

Max. Output

Power (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation

(%)

Avg. EFF (%) 25,50,75,100%

load

No load Power Consumption(W)

Measured at the

output ofGPSU15X-0 3~5 2.44~1.44 7.3 50 ±1 ±6 55 <0.3 3.3 GPSU15X-1 5~6 2.4~2.00 12 50 ±0.5 ±5 74.78 <0.3 5 GPSU15X-1-1 6~8 2.00~1.50 12 80 ±0.5 ±5 78.3 <0.3 7.5 GPSU15X-2 8~11 1.80~1.36 15 80 ±0.5 ±5 79.7 <0.3 9 GPSU15X-3 11~13 1.36~1.15 15 80 ±0.5 ±3 79.7 <0.3 12 GPSU15X-4 13~16 1.15~0.94 15 100 ±0.5 ±3 79.7 <0.3 15 GPSU15X-5 16~21 0.94~0.72 15 120 ±0.5 ±3 79.7 <0.3 18 GPSU15X-6 21~27 0.72~0.55 15 150 ±0.5 ±2 80 <0.3 24 GPSU15X-7 27~33 0.55~0.45 15 240 ±0.5 ±2 80 <0.3 28 GPSU15X-8 33~48 0.45~0.31 15 240 ±0.5 ±2 81 <0.3 48

Note: 1. Weight: Approx 70~100g 2. Optional output connectors (see page 81)

3. ENERGY STAR V Standard Output cable: 5~6V: 18AWG SPT-1 6FT

6~48V: 20AWG UL2468 6FT

<5> ↑

GPSU15 15W Desktop series (ENERGY STAR V) Desktop power supply Features:

Universal input voltage No load power consumption: <0.3W Meet ENERGY STAR V for 5~48VDC Single output Pass LPS Optional output connectors Short circuit protection High efficiency & reliability Outputs are available at request Compact package One year limited warranty

SAFETY AGENCY APPROVALS: Specifications: GPSU15 series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.5A Max. Leakage current 0.25mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating Chart Over voltage protection Yes, Protected by Zener diode Over current protection Yes. Auto-recovery

Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection Yes. Hiccup mode ; Auto- recovery Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40.See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up / Hold up / Rise time Typical: 3000mS / 16mS / 50mS at full load. Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Or see rating chart Insulation resistance 50Mohn minimum from input to output Inrush current 40 AMPS@115 VAC ; 60AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11

(B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003 Safety requirements (A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1 Warranty 1year

<6>

GPSU15 15W Desktop series (ENERGY STAR V)

X =A IEC-320-C14 (FIG1) or B IEC-320-C8 (FIG2) or C IEC-320-C6 (FIG3) or D MAINS CORD INPUT

Model name Output

Voltage(VDC) Output

Current(A)

Max. Output

Power (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation

(%)

Avg. EFF(%) 25,50,75,100%

load

No load Power Consumption(W)

Measured at the

output ofGPSU15X-0 3~5 2.44~1.44 7.3 50 ±1 ±6 55 <0.3 3.3 GPSU15X-1 5~6 2.40~2.00 12 50 ±0.5 ±5 74.78 <0.3 5 GPSU15X-1-1 6~8 2.00~1.50 12 80 ±0.5 ±5 78.3 <0.3 7.5 GPSU15X-2 8~11 1.80~1.36 15 80 ±0.5 ±5 79.7 <0.3 9 GPSU15X-3 11~13 1.36~1.15 15 80 ±0.5 ±3 79.7 <0.3 12 GPSU15X-4 13~16 1.15~0.94 15 100 ±0.5 ±3 79.7 <0.3 15 GPSU15X-5 16~21 0.94~0.72 15 120 ±0.5 ±3 79.7 <0.3 18 GPSU15X-6 21~27 0.72~0.55 15 150 ±0.5 ±2 80 <0.3 24 GPSU15X-7 27~33 0.55~0.45 15 240 ±0.5 ±2 80 <0.3 28 GPSU15X-8 33~48 0.45~0.31 15 240 ±0.5 ±2 81 <0.3 48

Y=U American type or E European type

Model name Output

Voltage(VDC)

Output

Current(A)

Max.

Output

Power (W)

Ripple(mV)

Max.

Line

Regulation

(%)

Load

Regulation

(%)

Avg. EFF (%)

25,50,75,100% load

No load Power

Consumption(W)

Measured at

the output of

GPSU15D-0-Y 3~5 2.44~1.44 7.3 50 ±1 ±6 55 <0.3 3.3

GPSU15D-1- Y 5~6 2.40~2.00 12 50 ±0.5 ±5 74.78 <0.3 5

GPSU15D-1-1-Y 6~8 2.00~1.50 12 80 ±0.5 ±5 78.3 <0.3 7.5

GPSU15D-2-Y 8~11 1.80~1.36 15 80 ±0.5 ±5 79.7 <0.3 9

GPSU15D-3-Y 11~13 1.36~1.15 15 80 ±0.5 ±3 79.7 <0.3 12

GPSU15D-4-Y 13~16 1.15~0.94 15 100 ±0.5 ±3 79.7 <0.3 15

GPSU15D-5-Y 16~21 0.94~0.72 15 120 ±0.5 ±3 79.7 <0.3 18

GPSU15D-6-Y 21~27 0.72~0.55 15 150 ±0.5 ±2 80 <0.3 24

GPSU15D-7-Y 27~33 0.55~0.45 15 240 ±0.5 ±2 80 <0.3 28

GPSU15D-8-Y 33~48 0.45~0.31 15 240 ±0.5 ±2 81 <0.3 48

Note: 1. Weight: Approx 100~250g 2. Optional output connectors (see page 81)

3. ENERGY STAR V Standard Output cable: 5~6V: 18AWG SPT-1 6FT

6~48V: 20AWG UL2468 6FT

<7>

GPSU18 18W Wall mount series

Features: Universal input voltage Meet ENERGY STAR V Single output Pass LPS Optional output connectors Short circuit protection Over voltage protection Over current protection Low leakage current <0.1mA One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: GPSU18 series: Input voltage 100~240VAC Input frequency 47~63Hz Input current 0.7A Max. Leakage current 0.1mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes, Protected by Zener diode Over current protection Yes. Auto-recovery Short circuit protection Yes. Hiccup mode ; Auto-recovery Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40.See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up / Hold up / Rise time Typical: 3000mS / 16mS / 50mS at full load. Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Or see rating chat Insulation resistance 50Mohm. minimum from input to output Inrush current 50 AMPS@115 VAC ; 90AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:EN55022 / EN55024 Class B

(B)FCC Part 15 Safety requirements Reference Design to (A)ES60601-1 (B)EN60601-1 (C)IEC 60950-1 (D) J60950-1 Warranty 1 year

<8>

GPSU18 18W Wall mount series

X=U American type (FIG1) or E European type (FIG2) or SA 2pin Australian type (FIG3) or BS UK type (FIG4)

Model name Output

Voltage(VDC) Output

Current(A)

Max. Output

Power (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation

(%)

Avg. EFF (%) 25,50,75,100%

load

No load Power Consumption(W)

Measured at the

output ofGPSU18X-1 5~6 3.00–2.50 15 80 ±1 ±5 76.42 <0.3 5 GPSU18X-1-1 6~8 2.50-1.87 15 80 ±1 ±5 79.20 <0.3 7.5 GPSU18X-2 8~11 2.25-1.64 18.04 100 ±1 ±5 80.30 <0.3 9 GPSU18X-3 11~13 1.64-1.38 18.04 120 ±1 ±5 82.40 <0.1 12 GPSU18X-4 13~16 1.38-1.13 18.08 150 ±1 ±5 82.40 <0.1 15 GPSU18X-5 16~21 1.13-0.86 18.08 150 ±1 ±5 82.40 <0.1 18 GPSU18X-6 21~27 0.86-0.67 18.09 150 ±1 ±5 82.40 <0.1 24 GPSU18X-7 27~33 0.67-0.55 18.15 240 ±1 ±3 82.40 <0.1 28 GPSU18X-8 33~58 0.55-0.32 18.56 240 ±1 ±3 82.40 <0.1 48

Note:

1. Weight: Approx

2. Optional output connectors (see page 81)

3. ENERGY STAR V Standard output cable: 5~13V: 20AWG / UL2468 / 4FT

13~58V: 22WG / UL2468 / 6FT

↑ <9>

Derating

100%

20%

40%

60%70%

20 C10 C 30 C 40 C 50 CAmbient temperature( c)

Typical static characteristics

60 85 100 26490

100%

60%

80%

0

23.8

12.731.8

22

24

75.5

1.5

17.2

68.5

3920

75.5

32

5

120°

6.3

7.91.6

24

22

75.5

17.06

9.88.5

3239.8

3920

75.5

12

5

22.248.8

21.742

75.5

22

24

6.58.5

9.517.6

4 8

22.7

3920

75.5

12

F1G 1(UL) F1G 2(TUV)

F1G 3(SA) F1G 4(UK)

22

24

75.5

32

5

8.5

3920

75.5

17.935.7

18.2

18.6

14 1212

NAME PLATE NAME PLATE

NAME PLATE

NAME PLATE

GPSU18 18W Wall mount interchangeable series Features:

Universal input voltage Meet ENERGY STAR V Single output Pass LPS Optional output connectors Short circuit protection Over voltage protection Over current protection Low leakage current <0.1mA One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: GPSU18 series: Input voltage 100~240VAC Input frequency 47~63Hz Input current 0.7A Max. Leakage current 0.1mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes, Protected by Zener diode Over current protection Yes. Auto-recovery Short circuit protection Yes. Hiccup mode ; Auto-recovery Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40.See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up / Hold up / Rise time Typical: 3000mS / 16mS / 50mS at full load. Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Or see rating chat Insulation resistance 50Mohm. minimum from input to output Inrush current 50 AMPS@115 VAC ; 90AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:EN55022 / EN55024 Class B

(B)FCC Part 15 Safety requirements Reference Design to (A)ES60601-1 (B)EN60601-1 (C)IEC 60950-1 (D) J60950-1 Warranty 1 year

<10>

GPSU18 18W Wall mount series

X=U American type (FIG1) or E European type (FIG2) or SA 2pin Australian type (FIG3) or BS UK type (FIG4)

Model name Output

Voltage(VDC) Output

Current(A)

Max. Output

Power (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation

(%)

Avg. EFF (%) 25,50,75,100%

load

No load Power Consumption(W)

Measured at the

output ofGPSU18X-1 5~6 3.00–2.50 15 80 ±1 ±5 76.42 <0.3 5 GPSU18X-1-1 6~8 2.50-1.87 15 80 ±1 ±5 79.20 <0.3 7.5 GPSU18X-2 8~11 2.25-1.64 18.04 100 ±1 ±5 80.30 <0.3 9 GPSU18X-3 11~13 1.64-1.38 18.04 120 ±1 ±5 82.40 <0.1 12 GPSU18X-4 13~16 1.38-1.13 18.08 150 ±1 ±5 82.40 <0.1 15 GPSU18X-5 16~21 1.13-0.86 18.08 150 ±1 ±5 82.40 <0.1 18 GPSU18X-6 21~27 0.86-0.67 18.09 150 ±1 ±5 82.40 <0.1 24 GPSU18X-7 27~33 0.67-0.55 18.15 240 ±1 ±3 82.40 <0.1 28 GPSU18X-8 33~58 0.55-0.32 18.56 240 ±1 ±3 82.40 <0.1 48

Note:

1. Weight: Approx

2. Optional output connectors (see page 81)

3. ENERGY STAR V Standard output cable: 5~13V: 20AWG / UL2468 / 4FT

13~58V: 22WG / UL2468 / 6FT

↑ <11>

Derating

100%

20%

40%

60%70%

20 C10 C 30 C 40 C 50 CAmbient temperature( c) Typical static characteristics

60 85 100 26490

100%

60%

80%

0

PU

SH

OPEN

LOCK

39.1 33

32

35.3

24

5

80.5

22

6.7

17.2

15.5

40.7

12.7 PU

SH

OPEN

LOCK

2439.1

35.3

22 580.5

18.1

19.2

5.7

15.5

40.7

OPEN

LOCK

PU

SH41

80.5

24

22

5

39.1

35.3

17

8.7

15.5

40.7

OPEN

LOCK

PU

SH

42.3

24

22

80.5

22.249.4

17.6 22.8

8.2

15.5

40.7

5

F1G 1(UL) F1G 2(TUV)

F1G 3(SA) F1G 4(UK)

NAME PLATE NAME PLATE

NAME PLATE

NAME PLATE

PUSHO

PE

NLOC

K

OP

EN

LOC

K

PUSH

OP

ENLO

CK

PUSH

PUSH

OP

EN

LOC

K

(UL) (TUV)

(SA) (UK)

PUSH

OP

EN

LOC

K

GPSU18 18W Desktop series

Features: Universal input voltage Meet ENERGY STAR V Single output Pass LPS Optional output connectors Short circuit protection Over voltage protection Over current protection Low leakage current <0.1mA One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: GPSU18 series: Input voltage 100~240VAC Input frequency 47~63Hz Input current 0.7A Max. Leakage current 0.1mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes, Protected by Zener diode Over current protection Yes. Auto-recovery Short circuit protection Yes. Hiccup mode ; Auto-recovery Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40.See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up / Hold up / Rise time Typical: 3000mS / 16mS / 50mS at full load. Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Or see rating chat Insulation resistance 50Mohm. minimum from input to output Inrush current 50 AMPS@115 VAC ; 90AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:EN55022 / EN55024 Class B

(B)FCC Part 15 Safety requirements Reference Design to (A)ES60601-1 (B)EN60601-1 (C)IEC 60950-1 (D) J60950-1 Warranty 1 year

<12>

GPSU18 18W Wall mount series

X=A IEC-320-C14 (FIG1) or B IEC-320-C8 (FIG2) or C IEC-320-C6 (FIG3) or D MAINS CORD INPUT

Model name Output

Voltage(VDC) Output

Current(A)

Max. Output

Power (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation

(%)

Avg. EFF (%) 25,50,75,100%

load

No load Power Consumption(W)

Measured at the

output ofGPSU18X-1 5~6 3.00–2.50 15 80 ±1 ±5 76.42 <0.3 5 GPSU18X-1-1 6~8 2.50-1.87 15 80 ±1 ±5 79.20 <0.3 7.5 GPSU18X-2 8~11 2.25-1.64 18.04 100 ±1 ±5 80.30 <0.3 9 GPSU18X-3 11~13 1.64-1.38 18.04 120 ±1 ±5 82.40 <0.1 12 GPSU18X-4 13~16 1.38-1.13 18.08 150 ±1 ±5 82.40 <0.1 15 GPSU18X-5 16~21 1.13-0.86 18.08 150 ±1 ±5 82.40 <0.1 18 GPSU18X-6 21~27 0.86-0.67 18.09 150 ±1 ±5 82.40 <0.1 24 GPSU18X-7 27~33 0.67-0.55 18.15 240 ±1 ±3 82.40 <0.1 28 GPSU18X-8 33~58 0.55-0.32 18.56 240 ±1 ±3 82.40 <0.1 48

Note:

1. Weight: Approx

2. Optional output connectors (see page 81)

3. ENERGY STAR V Standard output cable: 5~13V: 20AWG / UL2468 / 4FT

13~58V: 22WG / UL2468 / 6FT

↑ <13>

FIG 1

58.5

FIG 2

58.5

FIG 3

58.5

10029.25

32.8

58.5

32.8

GPSU30 30W Desktop series (ENERGY STAR V)

Desktop power supply Features:

Universal input voltage No load power consumption<0.3W Vout above 9V meet ENERGY STAR V Single output Pass LPS for 8~50V output Optional output connectors Short circuit protection Over voltage protection Over current protection One year limited warranty

SAFETY AGENCY APPROVALS: Specifications: GPSU30 series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.7A Max. Leakage current Class1:3.5mA/Class2:0.25mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes. Protected by Zener diode. Rated output voltage 110~140% Over current protection Yes. Hiccup mode; Auto-recovery. Rated output current>110% Short circuit protection Yes. Hiccup mode; Auto-recovery. Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change. Operating temperature 0~+40. See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up / Hold up / Rise time Typical:3000ms/ 10ms/50ms at full load Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Or see rating chart Insulation resistance 50Mohm minimum from input to output Inrush current 65AMPS@115 VAC ; 95AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11

(B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003 (C)VCCI:J55022(H14)V-3 / 06.04 and V-4/06.04

Safety requirements (A)UL60950-1; CSA C22.2 (B) EN60950-1;IEC60950-1 (C) J60950 Warranty 1year

<14>

GPSU30 30W Desktop series (ENERGY STAR V)

X=A IEC-320-C14 (FIG1) or B IEC-320-C8 (FIG2) or C IEC-320-C6 (FIG3) or D=MAINS CORD INPUT

Model name Output

Voltage(VDC)

Output

Current(A)

Max.

Output

Power (W)

Ripple(mV)

Max.

Line

Regulation

(%)

Load

Regulation

(%)

Avg. EFF (%)

25,50,75,100%

load

No load Power

Consumption(W)

Measured at the

output of

*GPSU30X-0 3~5 5 15~25 50 ±0.5 8(Note1) 64 <0.3 3.3 *GPSU30X-1 5~6 5.00~4.17 25 50 ±0.5 8(Note1) 70 <0.3 5 *GPSU30X-1-1 6~8 4.15~3.13 25 80 ±0.5 ±5 76 <0.3 7.5 GPSU30X-2 8~11 3.71~2.73 30 80 ±0.5 ±5 83.49 <0.3 9 GPSU30X-3 11~13 2.70~2.31 30 120 ±0.5 ±5 83.49 <0.3 12 GPSU30X-4 13~16 2.29~1.88 30 140 ±0.5 ±3 83.49 <0.3 15 GPSU30X-5 16~21 1.86~1.43 30 140 ±0.5 ±3 84 <0.3 18 GPSU30X-6 21~27 1.43~1.12 30 150 ±0.5 ±3 84 <0.3 24 GPSU30X-7 27~33 1.12~0.91 30 240 ±0.5 ±2 84 <0.3 28 GPSU30X-8 33~50 0.91~0.61 30.5 240 ±0.5 ±2 84 <0.3 48

Y= U1 3Pin American type AC power cord (with FG) or U 2Pin American type AC power cord or E European type AC power cord

Model name Output

Voltage(VDC)

Output

Current(A)

Max.

Output

Power (W)

Ripple(mV)

Max.

Line

Regulation

(%)

Load

Regulation

(%)

Avg. EFF (%)

25,50,75,100%

load

No load Power

Consumption(W)

Measured at the

output of

*GPSU30D-0-Y 3~5 5 15~25 50 ±0.5 8(Note1) 64 <0.3 3.3 *GPSU30D-1-Y 5~6 5.00~4.17 25 50 ±0.5 8(Note1) 70 <0.3 5 *GPSU30D-1-1-Y 6~8 4.15~3.13 25 80 ±0.5 ±5 76 <0.3 7.5 GPSU30D-2-Y 8~11 3.71~2.73 30 80 ±0.5 ±5 83.49 <0.3 9 GPSU30D-3-Y 11~13 2.70~2.31 30 120 ±0.5 ±5 83.49 <0.3 12 GPSU30D-4-Y 13~16 2.29~1.88 30 140 ±0.5 ±3 83.49 <0.3 15 GPSU30D-5-Y 16~21 1.86~1.43 30 140 ±0.5 ±3 84 <0.3 18 GPSU30D-6-Y 21~27 1.43~1.12 30 150 ±0.5 ±3 84 <0.3 24 GPSU30D-7-Y 27~33 1.12~0.91 30 240 ±0.5 ±2 84 <0.3 28 GPSU30D-8-Y 33~50 0.91~0.61 30.5 240 ±0.5 ±2 84 <0.3 48

*NO LPS SAFETY Note: (1) The load regulation c/be at ±5% with remote sensor (2) Weight: Approx300~400g

(3) Optional output connectors (see page 81) (4) ENERGY STAR V Standard Output cable: 8~11V: 16AWG SPT-2 4FT

11~50V: 18AWG SPT-1 6FT <15>

GPSU40 40W Desktop series (ENERGY STAR V) Desktop power supply Features:

Universal input voltage No load power consumption<0.3W Meet CEC(2008)/EISA Meet ENERGY STAR V Single output Pass LPS for 11~50V output Optional output connectors Short circuit protection Over voltage protection Over current protection One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: GPSU40 series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 1A Max. Leakage current Class1:3.5mA/Class2:0.25mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes. Protected by Zener diode. Rated output voltage 110~140% Over current protection Yes. Hiccup mode; Auto-recovery. Rated output current>110% Short circuit protection Yes. Hiccup mode; Auto-recovery. Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40. See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up / Hold up / Rise time Typical:1000ms/ 10ms/50ms at full load Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical ±5% variations from minimum to maximum output current. Insulation resistance 50Mohm minimum from input to output Inrush current 60AMPS@115 VAC ; 80AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11

(B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003 (C)VCCI:J55022(H14)V-3 / 06.04 and V-4/06.04

Safety requirements (A)UL60950-1; CSA C22.2 (B) EN60950-1;IEC60950-1 (C) J60950 Warranty 1year

<16>

GPSU40 40W Desktop series (ENERGY STAR V)

X=A IEC-320-C14 (FIG1) or B IEC-320-C8 (FIG2) or C IEC-320-C6 (FIG3) or D=MAINS CORD INPUT

Model name Output

Voltage(VDC) Output

Current(A)

Max. Output Power

(W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation (%)

Avg. EFF (%) 25,50,75,100%

load

No load Power Consumption(W)

Measured at the

output of

*GPSU40X-1 5~6 5.00~4.17 25 200 1 6 80.24 <0.3 5

*GPSU40X-1-1 6~8 5.00~3.75 30 200 1 6 83.49 <0.3 6 *GPSU40X-2 8~11 4.38~3.18 35 120 1 5 84.46 <0.3 9 GPSU40X-3 11~13 3.64~3.08 40 130 1 5 85.30 <0.3 12 GPSU40X-4 13~16 3.08~2.50 40 250 1 5 85.30 <0.3 15 GPSU40X-5 16~21 2.82~2.15 45 250 1 5 86.03 <0.3 19 GPSU40X-6 21~27 2.15~1.67 45 300 1 5 86.03 <0.3 24 GPSU40X-7 27~33 1.67~1.37 45 300 1 5 86.03 <0.3 30 GPSU40X-8 33~50 1.37~0.90 45 400 1 5 86.03 <0.3 48

Y= U1 3Pin American type AC power cord (with FG) or U 2Pin American type AC power cord or E European type AC power cord

Model name Output

Voltage(VDC) Output

Current(A)

Max. Output Power

(W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation

(%)

Avg. EFF (%) 25,50,75,100%

load

No load Power Consumption(W)

Measured at the

output of

*GPSU40D-1-Y 5~6 5.00~4.17 25 200 1 6 80.24 <0.3 5 *GPSU40D-1-1-Y 6~8 5.00~3.75 30 200 1 6 83.49 <0.3 6 *GPSU40D-2-Y 8~11 4.38~3.18 35 120 1 5 84.46 <0.3 9 GPSU40D-3-Y 11~13 3.64~3.08 40 130 1 5 85.30 <0.3 12 GPSU40D-4-Y 13~16 3.08~2.50 40 250 1 5 85.30 <0.3 15 GPSU40D-5-Y 16~21 2.82~2.15 45 250 1 5 86.03 <0.3 19 GPSU40D-6-Y 21~27 2.15~1.67 45 300 1 5 86.03 <0.3 24 GPSU40D-7-Y 27~33 1.67~1.37 45 300 1 5 86.03 <0.3 30 GPSU40D-8-Y 33~50 1.37~0.90 45 400 1 5 86.03 <0.3 48

*NO LPS SAFETY Note: (1) Weight: Approx250~400g

(2) Optional output connectors (see page 81) (3) ENERGY STAR V standard output cable: 5~11V : 16AWG SPT-1 4FT

11~50V: 18AWG SPT-1 6FT

<17> ↑

A2-50 50W Desktop series (ENERGY STAR V) Desktop power supply Features:

Meet ENERGY STAR V CE compliance Over voltage protection installation Short circuit protective installation Over current protective optional Compact size

SAFETY AGENCY APPROVALS:

Specifications: A2-50 series:

Input voltage 100~240VAC

Input frequency 50~60Hz

Input current 1.5A Max.

Leakage current Class1:3.5mA/Class2:0.25mA Max.@240VAC/50Hz

Output voltage See rating chart

Output current See rating chart

Output power range See rating chart

Ripple See rating chart

Over voltage protection Yes.

Over current protection Yes. Auto-recovery

Short circuit protection Yes. Auto-recovery

Temperature coefficient All output±0.04%/ maximum

Transient response Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature 0~+40. See derating curve

Storage temperature -40~+85

Relative humidity 5% to 95% non-condensing

Derating Derated from 100% at + 40 linearly to 70% at 50

Avg.Efficiency 87% min

Setup up/Hold - up/ Rise time Typical:3000ms / 10ms / 50ms at full load

Line regulation ±2% maximum for any input voltage change between input voltage range

Load regulation Typical ±5% variations from minimum to maximum output current.

Insulation resistance 50Mohm minimum from input to output

Inrush current 100AMPS @ 230VAC at 25 cold start

Withstand voltage 4242VDC from input to output

Mean time between failure 40000 hours minimum at full load at 25 ambient

EMI requirements (A)CE:Emission:EN55022; EN61000-3-2,3/ Immunity;IEC61000-4-2,3,4,5,6,11

Safety requirements (A)EN60950-1; IEC60950-1

Warranty 1year

<18>

A2-50 50W Desktop series (ENERGY STAR V)

X=V IEC-320-C14 (FIG1) or U IEC-320-C8 (FIG2) or W IEC-320-C6 (FIG3)

Model name Output Voltage(VDC)

Output Current(A)

Max. OutputPower (W)

Ripple (mV) Max.

Line Regulation

(%)

Load Regulation

(%)

Avg. Eff (%) 25,50,75,100%

load

No load Power Consumption(W)

A2-50S12R-X 12 4.16 50 250 ±2 ±5 87 <0.5 A2-50S12R-X 12.5 4.0 50 250 ±2 ±5 87 <0.5 A2-50S12R-X 13 3.84 50 250 ±2 ±5 87 <0.5 A2-50S12R-X 13.5 3.70 50 250 ±2 ±5 87 <0.5 A2-50S12R-X 14 3.57 50 250 ±2 ±5 87 <0.5 A2-50S12R-X 14.5 3.44 50 250 ±2 ±5 87 <0.5 A2-50S12R-X 15 3.33 50 250 ±2 ±5 87 <0.5 A2-50S12R-X 15.5 3.22 50 250 ±2 ±5 87 <0.5 A2-50S12R-X 16 3.12 50 250 ±2 ±5 87 <0.5 A2-50S12R-X 16.5 3.03 50 250 ±2 ±5 87 <0.5 A2-50S12R-X 17 2.94 50 250 ±2 ±5 87 <0.5

X=V IEC-320-C14 (FIG1) or U IEC-320-C8 (FIG2) or W IEC-320-C6 (FIG3)

Model name Output Voltage(VDC)

Output Current(A)

Max. OutputPower (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation

(%)

Avg. Eff (%) 25,50,75,100%

load

No load Power Consumption(W)

A2-50S18R-X 18 2.77 50 250 ±2 ±5 87 <0.5 A2-50S18R-X 18.5 2.70 50 250 ±2 ±5 87 <0.5 A2-50S18R-X 19 2.63 50 250 ±2 ±5 87 <0.5 A2-50S18R-X 19.5 2.56 50 250 ±2 ±5 87 <0.5 A2-50S18R-X 20 2.50 50 250 ±2 ±5 87 <0.5 A2-50S18R-X 20.5 2.43 50 250 ±2 ±5 87 <0.5 A2-50S18R-X 21 2.38 50 250 ±2 ±5 87 <0.5 A2-50S18R-X 21.5 2.32 50 250 ±2 ±5 87 <0.5 A2-50S18R-X 22 2.27 50 250 ±2 ±5 87 <0.5 A2-50S18R-X 22.5 2.22 50 250 ±2 ±5 87 <0.5 A2-50S18R-X 23 2.17 50 250 ±2 ±5 87 <0.5 A2-50S18R-X 23.5 2.12 50 250 ±2 ±5 87 <0.5 A2-50S18R-X 24 2.08 50 250 ±2 ±5 87 <0.5 Note: (1) Weight: Approx250g (2) Optional output connectors (see page 81)

(3) ENERGY STAR V standard output cable: 18AWG / 4FT / SPT-1

↑ <19>

331 FIG 1(V)

331 FIG 2(U)

331 FIG 3(W)

UNIT: mm100

56

INDICATOR LED

A2-60;A2-65 60~65W Desktop series (ENERGY STAR V) Desktop power supply Features:

Meet ENERGY STAR V CE compliance Over voltage protection installation Short circuit protective installation Over current protective optional Compact size

SAFETY AGENCY APPROVALS

Specifications: A2-60;A2-65 series:

Input voltage 100~240VAC

Input frequency 50~60Hz

Input current 1.5A Max.

Leakage current Class1:3.5mA/Class2:0.25mA Max.@240VAC/50Hz

Output voltage See rating chart

Output current See rating chart

Output power range See rating chart

Ripple See rating chart

Over voltage protection Yes.

Over current protection Yes. Auto-recovery

Short circuit protection Yes. Auto-recovery

Temperature coefficient All output±0.04%/ maximum

Transient response Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature 0~+40. See derating curve

Storage temperature -40~+85

Relative humidity 5% to 95% non-condensing

Derating Derated from 100% at + 40 linearly to 70% at 50

Avg.Efficiency 87% min

Setup up/Hold up/ Rise time Typical:3000ms / 10ms / 50ms at full load

Line regulation ±2% maximum for any input voltage change between input voltage range

Load regulation Typical ±5% variations from minimum to maximum output current.

Insulation resistance 50Mohm minimum form input to output

Inrush current 100AMPS @ 230VAC at 25 cold start

Withstand voltage 4242VDC from input to output

Mean time between failure 40000 hours minimum at full load at 25 ambient

EMI requirements (A)CE : Emission:EN55022; EN61000-3-2,3 / Immunity; IEC61000-4-2,3,4,5,6,11

Safety requirements (A)EN60950-1; IEC60950-1

Warranty 1year <20>

A2-60;A2-65 60~65W Desktop series (ENERGY STAR V)

X=V IEC-320-C14 (FIG1) or U IEC-320-C8 (FIG2) or W IEC-320-C6 (FIG3)

Model name Output

Voltage(VDC) Output

Current(A) Max. Output Power (W)

Ripple(mV)Max.

Line Regulation (%)

Load Regulation (%)

Avg. EFF (%) 25,50,75,100% load

No load Power Consumption(W)

A2-60S12R-X 12 5.0 60 250 ±2 ±5 87 <0.5 A2-60S12R-X 12.5 4.80 60 250 ±2 ±5 87 <0.5 A2-60S12R-X 13 4.61 60 250 ±2 ±5 87 <0.5 A2-60S12R-X 13.5 4.44 60 250 ±2 ±5 87 <0.5 A2-60S12R-X 14 4.28 60 250 ±2 ±5 87 <0.5 A2-60S12R-X 14.5 4.13 60 250 ±2 ±5 87 <0.5 A2-60S12R-X 15 4.0 60 250 ±2 ±5 87 <0.5 A2-60S12R-X 15.5 3.87 60 250 ±2 ±5 87 <0.5 A2-60S12R-X 16 3.75 60 250 ±2 ±5 87 <0.5 A2-60S12R-X 16.5 3.63 60 250 ±2 ±5 87 <0.5 A2-60S12R-X 17 3.52 60 250 ±2 ±5 87 <0.5

X=V IEC-320-C14 (FIG1) or U IEC-320-C8 (FIG2) or W IEC-320-C6 (FIG3)

Model name Output

Voltage(VDC)

Output

Current(A)

Max. Output

Power (W)

Ripple(mV)

Max.

Line Regulation

(%)

Load

Regulation (%)

Avg. EFF (%)

25,50,75,100% load

No load Power

Consumption(W)

A2-60S18R-X 18 3.33 60 300 ±2 ±5 87 <0.5 A2-60S18R-X 18.5 3.24 60 300 ±2 ±5 87 <0.5 A2-60S18R-X 19 3.15 60 300 ±2 ±5 87 <0.5 A2-60S18R-X 19.5 3.07 60 300 ±2 ±5 87 <0.5 A2-60S18R-X 20 3.0 60 300 ±2 ±5 87 <0.5 A2-60S18R-X 20.5 2.92 60 360 ±2 ±5 87 <0.5 A2-60S18R-X 21 2.85 60 360 ±2 ±5 87 <0.5 A2-60S18R-X 21.5 2.79 60 360 ±2 ±5 87 <0.5 A2-60S18R-X 22 2.72 60 360 ±2 ±5 87 <0.5 A2-60S18R-X 22.5 2.66 60 360 ±2 ±5 87 <0.5 A2-60S18R-X 23 2.60 60 360 ±2 ±5 87 <0.5 A2-60S18R-X 23.5 2.55 60 360 ±2 ±5 87 <0.5 A2-60S18R-X 24 2.50 60 360 ±2 ±5 87 <0.5

X=V IEC-320-C14 (FIG1) or U IEC-320-C8 (FIG2) or W IEC-320-C6 (FIG3)

Model name Output

Voltage(VDC)

Output

Current(A)

Max. Output

Power (W)

Ripple(mV)

Max.

Line Regulation

(%)

Load

Regulation (%)

Avg. EFF (%)

25,50,75,100% load

No load Power

Consumption(W)

A2-65S18R-X 18 3.61 65 300 ±2 ±5 87 <0.5 A2-65S18R-X 18.5 3.51 65 300 ±2 ±5 87 <0.5 A2-65S18R-X 19 3.42 65 300 ±2 ±5 87 <0.5 A2-65S18R-X 19.5 3.33 65 300 ±2 ±5 87 <0.5 A2-65S18R-X 20 3.25 65 300 ±2 ±5 87 <0.5 A2-65S18R-X 20.5 3.17 65 360 ±2 ±5 87 <0.5 A2-65S18R-X 21 3.09 65 360 ±2 ±5 87 <0.5 A2-65S18R-X 21.5 3.02 65 360 ±2 ±5 87 <0.5 A2-65S18R-X 22 2.95 65 360 ±2 ±5 87 <0.5 A2-65S18R-X 22.5 2.88 65 360 ±2 ±5 87 <0.5 A2-65S18R-X 23 2.82 65 360 ±2 ±5 87 <0.5 A2-65S18R-X 23.5 2.76 65 360 ±2 ±5 87 <0.5 A2-65S18R-X 24 2.70 65 360 ±2 ±5 87 <0.5 Note: (1) Weight: Approx250g (2) Optional output connectors (see page 81) (3) ENERGY STAR V standard output cable: 18AWG / 4FT / SPT-1

↑ <21>

331 FIG 1(V)

331 FIG 2(U)

331 FIG 3(W)

UNIT: mm100

56

INDICATOR LED

FIG 1 FIG 2

PSU66 66W Desktop series Desktop power supply Features:

Universal input voltage Single output Pass LPS for 13~48V output Optional output connectors High efficiency & reliability Compact package Over voltage protection Over current protection Optional input inlets One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: PSU66 series:

Input voltage 100~240VAC

Input frequency 50~60Hz

Input current 1.5A Max.

Leakage current 3.5mA Max.@240VAC/50Hz

Output voltage See rating chart

Output current See rating chart

Output power range See rating chart

Ripple See rating chart

Over voltage protection Provided on outputs set at 112~132% of its nominal output voltage

Over current protection All outputs protected to short circuit conditions

Temperature coefficient All output±0.04%/ maximum

Transient response Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature 0~+30. See derating curve

Storage temperature -40~+85

Relative humidity 5% to 95% non-condensing

Derating Derated from 100% at + 30 linearly to 70% at 50

Efficiency See rating chart

Hold - up time 10msec minimum

Line regulation ±1% maximum for any input voltage change between input voltage range

Load regulation ±5% variations from minimum to maximum output current.

Insulation resistance 50Mohm minimum from input to output

Inrush current 15AMPS @ 115VAC or 30AMPS @ 230VAC at 25 cold start

Withstand voltage 4242VDC from input to output

Mean time between failure 50,000 hours minimum at full load at 25 ambient

EMI requirements Meet CE standards

Safety requirements Meets or exceeds :(A)UL60950-1(B) CSA C22.2 (C)TUV EN60950-1; IEC960

Warranty 1year

<22>

PSU66 66W Desktop series

X=A IEC-320-C14 (FIG1) or C IEC-320-C6 (FIG2)

Model name Output

Voltage(VDC) Output

Current(A)

Max. Output

Power (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation

(%) Efficiency(%)(min)

Measured at the output of

*PSU60X-0 3~5 8.00~4.80 24 50 1 10 60 3.3 *PSU60X-1 5~6 8.50~7.50 42.5 50 1 8 63 5 *PSU60X-1-1 6~8 8.00~6.00 48 80 1 5 74 7.5 *PSU60X-2 8~11 6.25~5.00 50 80 1 5 74 9 *PSU60X-3 11~13 6.00~5.08 66 80 1 5 75 12 PSU60X-4 13~16 5.08~4.13 66 100 1 3 75 15 PSU60X-5 16~21 4.13~3.14 66 100 1 3 75 18 PSU60X-6 21~27 3.14~2.44 66 150 1 2 75 24 PSU60X-7 27~33 2.44~2.00 66 150 1 2 75 30 PSU60X-8 33~48 2.00~1.38 66 150 1 2 75 48

*NO LPS SAFETY

Note: (1) Weight: Approx300~350g (2) Optional output connectors (see page 81)

<23>

FIG 1 FIG 2

GPSU70 70W Desktop series (ENERGY STAR V) Desktop power supply Features:

Universal input voltage Meet ENERGY STAR V Single output Short circuit protection Over voltage protection Over current protection Low leakage current Output voltage 5~58VDC One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: GPSU70 series:

Input voltage 100~240VAC

Input frequency 50~60Hz

Input current 1.8~0.8A Max.

Leakage current <0.3mA

Output voltage See rating chart

Output current See rating chart

Output power range See rating chart

Ripple See rating chart

Over voltage protection Yes.<140% output voltage

Over current protection Yes.>120% output current, Auto-recover

Short protection Yes. Hiccup mode, Auto-recover

Temperature coefficient All output±0.04%/ maximum

Transient response Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature -20~+40.

Storage temperature -40~+85

Relative humidity 5% to 95% non-condensing

Derating Derated from 100% at + 30 linearly to 50% at 70

Avg.Efficiency See rating chart

Hold - up time 8ms minimum

Line regulation ±1% maximum for any input voltage change between input voltage range

Load regulation ±5% variations from minimum to maximum output current.

Insulation resistance 50Mohm minimum from input to output

Inrush current 100AMPS @ 230VAC at 25 cold start

Withstand voltage 4242VDC from input to output

Mean time between failure 100,000 hours minimum at full load at 25 ambient

EMI requirements (A)Meet CE :EN55022 CLASS B; EN55024; J55022(H22) (B)FCC PART 15 B

Safety requirements (A)UL60950-1(B) EN60950-1(C)J60950-1(H22)

Warranty 1year

<24>

GPSU70 70W Desktop series (ENERGY STAR V)

X=A (C14 FIG1) or C (C6 FIG2)

Model name Output

Voltage(VDC) Output

Current(A)

Max. Output

Power (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation (%)

Avg. EFF (%) 25,50,75,100%

load

Measured at the output of

GPSU70X-1 5~6 7.50~6.36 37.5 200 ±1 ±5 83.4 5 GPSU70X-1-1 6~8 7.50~5.63 45 100 ±1 ±5 86.10 7.5 GPSU70X-2 8~11 7.50~5.46 60 120 ±1 ±5 87 9 GPSU70X-3 11~13 6.37~5.39 70 120 ±1 ±5 87 12 GPSU70X-4 13~16 5.39~4.38 70 120 ±1 ±5 87 15 GPSU70X-5 16~21 4.38~3.34 70 180 ±1 ±5 87 18 GPSU70X-6 21~27 3.34~2.60 70 180 ±1 ±5 87 24 GPSU70X-7 27~33 2.60~2.13 70 240 ±1 ±5 87 32 GPSU70X-8 33~58 2.13~1.22 70 240 ±1 ±5 87 48

Note: (1) Weight: Approx370~375g (2) Optional output connectors (see page 81) (3) ENERGY STAR V standard output cable: 5~16V: UL1571 14AWG 4FT

17~58V: SPT-1 18AWG 6FT

<25>

PSU25 25W Desktop series Desktop power supply Features:

Universal input voltage Dual or triple outputs Optional output connectors High efficiency & reliability Compact package Over voltage protection Over current protection One year limited warranty

SAFETY AGENCY APPROVALS: Specifications: PSU25 series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.8A Max. Leakage current Class1:3.5mA/Class2:0.25mA Max.@240VAC/50Hz Output voltage See rating chart (±5% tolerance) Output current See rating chart Output power range 25 watts Max. Ripple 1% peak to peak maximum Over voltage protection Provided on outputs set at 112~132% of its nominal output voltage Over current protection All outputs protected to short circuit conditions Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40. Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 30 linearly to 70% at 50 Efficiency 65% minimum at full output Hold - up time 10msec minimum Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation ±5% variations from minimum to maximum output current. Insulation resistance 50Mohm minimum from input to output Inrush current 15AMPS@115 VAC or 30AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 50,000 hours minimum at full load at 25 ambient EMI requirements Meet CE standards Safety requirements Meets or exceeds(A)UL1950 (B) CSA C22.2 (C) TUV EN60950-1(D)IEC 950 Warranty 1year

<26>

PSU25 25W Desktop series

X=A IEC-320-C14 (FIG1) or B IEC-320-C8 (FIG2) or C IEC-320-C6 (FIG3) or D=MAINS CORD INPUT

Model name Output#1 Vnom lmax

Output#2 Vnom lmax

Output#3 Vnom lmax

Maximum Output Power

PSU25X-13 +5VDC 2.50A +12VDC 1.00A N/A 25W PSU25X-14 +5VDC 2.50A +15VDC 0.80A N/A 25W PSU25X-16 +5VDC 2.50A +24VDC 0.50A N/A 25W PSU25X-16-1 +5VDC 1.2A +24VDC 0.80A N/A 25W PSU25X-13D +5VDC 2.50A +12VDC 0.80A -12VDC 0.3A 25W PSU25X-14E +5VDC 2.50A +15VDC 0.50A -15VDC 0.3A 25W PSU25X-13A +5VDC 2.50A +12VDC 0.80A -5VDC 0.3A 25W

Y=U American Type or E European Type

Model name Output#1 Vnom lmax

Output#2 Vnom lmax

Output#3 Vnom lmax

Maximum Output Power

PSU25D-13-Y +5VDC 2.50A +12VDC 1.00A N/A 25W PSU25D-14-Y +5VDC 2.50A +15VDC 0.80A N/A 25W PSU25D-16-Y +5VDC 2.50A +24VDC 0.50A N/A 25W PSU25D-16-1-Y +5VDC 1.2A +24VDC 0.80A N/A 25W PSU25D-13D-Y +5VDC 2.50A +12VDC 0.80A -12VDC 0.3A 25W PSU25D-14E-Y +5VDC 2.50A +15VDC 0.50A -15VDC 0.3A 25W PSU25D-13A-Y +5VDC 2.50A +12VDC 0.80A -5VDC 0.3A 25W

Note: (1) Weight: Approx 300~350g (2)Optional output connectors (see page 81)

<27>

PSU50 50W Desktop series

Desktop power supply Features:

Universal input voltage Dual or triple outputs Optional input inlets High efficiency & reliability Compact package Over voltage protection Optional output connectors Over current protection Optional input inlets One year limited warranty

SAFETY AGENCY APPROVALS: Specifications: PSU50series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 1.6A Max. Leakage current 3.5mA Max.@240VAC/50Hz Output voltage See rating chart (±5% tolerance) Output current See rating chart Output power range 50 watts Max. Ripple 1% peak to peak maximum Over voltage protection Provided on outputs set at 112~132% of its nominal output voltage Over current protection All outputs protected to short circuit conditions Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+30 Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 30 linearly to 60% at 40 Efficiency 65% minimum at full output Hold - up time 10msec minimum Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation ±5% variations from minimum to maximum output current. Insulation resistance 50Mohm minimum from input to output Inrush current 15AMPS@115 VAC or 30AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 50,000 hours minimum at full load at 25 ambient EMI requirements Meet CE standards Safety requirements Meets or exceeds(A)UL1950 (B) CSA C22.2 (C) TUV EN60950-1(D)IEC 950 Warranty 1 year

<28>

PSU50 50W Desktop series

FIG1

Model name Output#1 Vnom lmax

Output#2 Vnom lmax

Output#3 Vnom lmax

Maximum Output Power

PSU50A-12 +5VDC 4.50A +9VDC 1.70A N/A 37.8W PSU50A-13 +5VDC 4.00A +12VDC 2.00A N/A 44W PSU50A-14 +5VDC 4.00A +15VDC 1.80A N/A 47W PSU50A-16 +5VDC 2.00A +24VDC 1.00A N/A 49W PSU50A-16-1 +5VDC 2.00A +24VDC 1.50A N/A 46W PSU50A-36 +12VDC 2.20A +24VDC 1.00A N/A 50.4W PSU50A-13D +5VDC 4.00A +12VDC 2.00A -12VDC 0.50A 50W PSU50A-14E +5VDC 4.00A +15VDC 1.50A -15VDC 0.50A 50W PSU50A-13D-1 +5VDC 5.00A +12VDC 1.00A -12VDC 0.25A 40W

FIG2

Model name Output#1 Vnom lmax

Output#2 Vnom lmax

Output#3 Vnom lmax

Maximum Output Power

PSU50C-12 +5VDC 4.50A +9VDC 1.70A N/A 37.8W PSU50C-13 +5VDC 4.00A +12VDC 2.00A N/A 44W PSU50C-14 +5VDC 4.00A +15VDC 1.80A N/A 47W PSU50C-16 +5VDC 2.00A +24VDC 1.00A N/A 49W PSU50C-16-1 +5VDC 2.00A +24VDC 1.50A N/A 46W PSU50C-36 +12VDC 2.20A +24VDC 1.00A N/A 50.4W PSU50C-13D +5VDC 4.00A +12VDC 2.00A -12VDC 0.50A 50W PSU50C-14E +5VDC 4.00A +15VDC 1.50A -15VDC 0.50A 50W PSU50C-13D-1 +5VDC 5.00A +12VDC 1.00A -12VDC 0.25A 40W

Note: (1) Weight: Approx 510~560g (2)Optional output connectors (see page 81) <29>

GMPU06 6W Wall mount series (FOR MEDICAL) Plug-in power supply Features:

Universal input voltage No load power consumption<0.3W Meet ENERGY STAR V Single output Optional output connectors Short circuit protection Over voltage protection Over current protection Means of patient protection design Possess risk analysis report Two years limited warranty

SAFETY AGENCY APPROVALS:

Specifications: GMPSU06 series: Input voltage 100~240VAC Input frequency 47~63Hz Input current 0.18~0.09A Max. Leakage current 0.1mA Max. Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes Over current protection Yes, Auto-recovery Short circuit protection Yes, Auto-recovery Temperature coefficient All output±0.04%/ maximum

Transient response Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 900n/sec after a 25% step load change

Operating temperature 0~+40 Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at+40 linearly to 50% at 70 Avg. Efficiency See rating chart Hold up time 8m / Sec. minimum Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation ±5% variations from minimum to maximum output current. Insulation resistance 50Mohm minimum from input to output Inrush current 30A Max @240 VAC/50Hz at 25 cold start Withstand voltage 5656VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)EN60601-1-2:2007 (B)FCC PART 15 & PART 18 CLASS B Safety requirements (A)UL: ES60601-1; (B)CSA:C22.2 NO.60601-1:2008 (C)EN60601-1:2006 Warranty 2years

<30>

GMPU06 6W Wall mount series (FOR MEDICAL)

50%

100%

70 85 264

50%40%

20%

60%70%

60C 70C10C 20C 30C 40C 50C

X=U American type (FIG1) or E European type (FIG2) X=S 3Pin Australian type (FIG3) or SA 2pin Australian type (FIG4) or BS UK type (FIG5)

Model name Output

Voltage(VDC) Output

Current(A) Max .Output Power (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation

(%)

Avg. EFF (%) 25,50,75,100%

load

No load Power Consumption(W)

Measured at the

output ofGMPU06X-1 5~6 1.20~1.00 6 80 ±1 ±5 69.54 <0.3 5 GMPU06X-11 5 1 5 80 ±1 ±5 68.2 <0.3 5 GMPU06X-1-1 6~8 1.00~0.75 6 80 ±1 ±5 74 <0.3 7.5 GMPU06X -2 8~11 0.75~0.55 6 80 ±1 ±5 74 <0.3 9 GMPU06X -3 11~13 0.55~0.46 6 120 ±1 ±5 74 <0.3 12 GMPU06X -4 13~16 0.46~0.38 6 150 ±1 ±5 74 <0.3 15 GMPU06X -5 16~21 0.38~0.30 6 180 ±1 ±5 74 <0.3 18 GMPU06X -6 21~24 0.30~0.25 6 200 ±1 ±5 74 <0.3 24

Note: 1. Weight: Approx 70~100g 2. Optional output connectors (see page 81)

3. ENERGY STAR V Standard Output cable: 5~8V:22AWG / UL2468 / 4FT ;

8~24V: 22AWG / UL2468 / 6FT

<31>

GMPU18 18W Wall mount series (FOR MEDICAL) Features:

Universal input voltage Meet ENERGY STAR V Single output Pass LPS Optional output connectors Short circuit protection Over voltage protection Over current protection Means of patient protection design Possess risk analysis report Meet 60601-1 3rd edition Two years limited warranty

SAFETY AGENCY APPROVALS:

Specifications: GMPU18 series: Input voltage 100~240VAC Input frequency 47~63Hz Input current 0.7A Max. Leakage current 0.1mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple 1% peak to peak maximum. See rating Chart Over voltage protection Yes, Protected by Zener diode Over current protection Yes. Auto-recovery Short circuit protection Yes. Hiccup mode ; Auto-recovery Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40.See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up / Hold up / Rise time Typical: 3000mS / 16mS / 50mS at full load. Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Or see rating chat Insulation resistance 50Mohm. minimum from input to output Inrush current 50 AMPS@115 VAC ; 90AMPS @ 230VAC at 25 cold start Withstand voltage 5656VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:EN60601-1-2:2007 CLASS B

(B)FCC Part 15 / Part 18 Subpart B Safety requirements (A)UL:ES60601-1:2005(B)CSA:C22.2 NO.60601-1:2008(C)EN60601-1:2006 Warranty 2 years

<32>

GMPU18 18W Wall mount series (FOR MEDICAL)

X=U American type (FIG1) or E European type (FIG2)

or SA 2pin Australian type (FIG3) or BS UK type (FIG4)

Model name Output

Voltage(VDC) Output

Current(A)

Max. Output

Power (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation

(%)

Avg. EFF (%) 25,50,75,100%

load

No load Power Consumption(W)

Measured at the

output ofGMPU18X-1 5~6 3.00–2.50 15 80 ±1 ±5 76.42 <0.3 5 GMPU18X-1-1 6~8 2.50-1.87 15 80 ±1 ±5 79.20 <0.3 7.5 GMPU18X-2 8~11 2.25-1.64 18.04 100 ±1 ±5 80.30 <0.3 9 GMPU18X-3 11~13 1.64-1.38 18.04 120 ±1 ±5 82.40 <0.1 12 GMPU18X-4 13~16 1.38-1.13 18.08 150 ±1 ±5 82.40 <0.1 15 GMPU18X-5 16~21 1.13-0.86 18.08 150 ±1 ±5 82.40 <0.1 18 GMPU18X-6 21~27 0.86-0.67 18.09 150 ±1 ±5 82.40 <0.1 24 GMPU18X-7 27~33 0.67-0.55 18.15 240 ±1 ±3 82.40 <0.1 28 GMPU18X-8 33~58 0.55-0.32 18.56 240 ±1 ±3 82.40 <0.1 48

Note: Note:

1. Weight: Approx

2. Optional output connectors (see page 81)

3. ENERGY STAR V Standard output cable: 5~13V: 20AWG / UL2468 / 4FT

13~58V: 22WG / UL2468 / 6FT

↑ <33>

Derating

100%

20%

40%

60%70%

20 C10 C 30 C 40 C 50 CAmbient temperature( c)

Typical static characteristics

60 85 100 26490

100%

60%

80%

0

23.8

12.731.8

22

24

75.5

1.5

17.2

68.5

3920

75.5

32

5

120°

6.3

7.91.6

24

22

75.5

17.06

9.88.5

3239.8

3920

75.5

12

5

22.248.8

21.742

75.5

22

24

6.58.5

9.517.6

4 8

22.7

3920

75.5

12

F1G 1(UL) F1G 2(TUV)

F1G 3(SA) F1G 4(UK)

22

24

75.5

32

5

8.5

3920

75.5

17.935.7

18.2

18.6

14 1212

NAME PLATE NAME PLATE

NAME PLATE

NAME PLATE

GMPU18 18W Wall mount interchangeable series (FOR MEDICAL) Features:

Universal input voltage Meet ENERGY STAR V Single output Pass LPS Optional output connectors Short circuit protection Over voltage protection Over current protection Means of patient protection design Possess risk analysis report Meet 60601-1 3rd edition Two years limited warranty

SAFETY AGENCY APPROVALS:

Specifications: GMPU18 series: Input voltage 100~240VAC Input frequency 47~63Hz Input current 0.7A Max. Leakage current 0.1mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple 1% peak to peak maximum. See rating Chart Over voltage protection Yes, Protected by Zener diode Over current protection Yes. Auto-recovery Short circuit protection Yes. Hiccup mode ; Auto-recovery Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40.See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up / Hold up / Rise time Typical: 3000mS / 16mS / 50mS at full load. Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Or see rating chat Insulation resistance 50Mohm. minimum from input to output Inrush current 50 AMPS@115 VAC ; 90AMPS @ 230VAC at 25 cold start Withstand voltage 5656VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:EN60601-1-2:2007 CLASS B

(B)FCC Part 15 / Part 18 Subpart B Safety requirements (A)UL:ES60601-1:2005(B)CSA:C22.2 NO.60601-1:2008(C)EN60601-1:2006 Warranty 2 years

<34>

GMPU18 18W Wall mount interchangeable series (FOR MEDICAL)

X=U American type (FIG1) or E European type (FIG2) or

or SA 2pin Australian type (FIG3) or BS UK type (FIG4)

Model name Output

Voltage(VDC) Output

Current(A)

Max. Output

Power (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation

(%)

Avg. EFF (%) 25,50,75,100%

load

No load Power Consumption(W)

Measured at the

output ofGMPU18X-1 5~6 3.00–2.50 15 80 ±1 ±5 76.42 <0.3 5 GMPU18X-1-1 6~8 2.50-1.87 15 80 ±1 ±5 79.20 <0.3 7.5 GMPU18X-2 8~11 2.25-1.64 18.04 100 ±1 ±5 80.30 <0.3 9 GMPU18X-3 11~13 1.64-1.38 18.04 120 ±1 ±5 85.10 <0.1 12 GMPU18X-4 13~16 1.38-1.13 18.08 150 ±1 ±5 85.10 <0.1 15 GMPU18X-5 16~21 1.13-0.86 18.08 150 ±1 ±5 85.10 <0.1 18 GMPU18X-6 21~27 0.86-0.67 18.09 150 ±1 ±5 85.10 <0.1 24 GMPU18X-7 27~33 0.67-0.55 18.15 240 ±1 ±3 85.10 <0.1 28 GMPU18X-8 33~58 0.55-0.32 18.56 240 ±1 ±3 85.10 <0.1 48

Note: Note:

1. Weight: Approx

2. Optional output connectors (see page 81)

3. ENERGY STAR V Standard output cable: 5~13V: 20AWG / UL2468 / 4FT

13~58V: 22WG / UL2468 / 6FT

↑ <35>

Derating

100%

20%

40%

60%70%

20 C10 C 30 C 40 C 50 CAmbient temperature( c)

Typical static characteristics

60 85 100 26490

100%

60%

80%

0

PU

SH

OPEN

LOCK

39.1 33

32

35.3

24

5

80.5

22

6.7

17.2

15.5

40.7

12.7 PU

SH

OPEN

LOCK

2439.1

35.3

22 580.5

18.1

19.2

5.7

15.5

40.7

OPEN

LOCK

PU

SH41

80.5

24

22

5

39.1

35.3

17

8.7

15.5

40.7

OPEN

LOCK

PU

SH

42.3

24

22

80.5

22.249.4

17.6 22.8

8.2

15.5

40.7

5

F1G 1(UL) F1G 2(TUV)

F1G 3(SA) F1G 4(UK)

NAME PLATE NAME PLATE

NAME PLATE

NAME PLATE

PUSH

OPENLO

CK

OPE

NLOC

K

PUSH

OPENLO

CK

PUSH

PUSH

OPENLO

CK

(UL) (TUV)

(SA) (UK)

PUSH

OPENLO

CK

GMPU18 18W Desktop series (FOR MEDICAL) Features:

Universal input voltage Meet ENERGY STAR V Single output Pass LPS Optional output connectors Short circuit protection Over voltage protection Over current protection Means of patient protection design Possess risk analysis report Meet 60601-1 3rd edition Two years limited warranty

SAFETY AGENCY APPROVALS:

Specifications: GMPU18 series: Input voltage 100~240VAC Input frequency 47~63Hz Input current 0.7A Max. Leakage current 0.1mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple 1% peak to peak maximum. See rating Chart Over voltage protection Yes, Protected by Zener diode Over current protection Yes. Auto-recovery Short circuit protection Yes. Hiccup mode ; Auto-recovery Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40.See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up / Hold up / Rise time Typical: 3000mS / 16mS / 50mS at full load. Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Or see rating chat Insulation resistance 50Mohm. minimum from input to output Inrush current 50 AMPS@115 VAC ; 90AMPS @ 230VAC at 25 cold start Withstand voltage 5656VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:EN60601-1-2:2007 CLASS B

(B)FCC Part 15 / Part 18 Subpart B Safety requirements (A)UL:ES60601-1:2005(B)CSA:C22.2 NO.60601-1:2008(C)EN60601-1:2006 Warranty 2 years

<36>

(Only FIG 2) (Only FIG 2) (Only FIG 2)

GMPU18 18W Wall mount series / Desktop series (FOR MEDICAL)

X=A IEC-320-C14 (FIG1) or B IEC-320-C8 (FIG2) or C IEC-320-C6 (FIG3) or D MAINS CORD INPUT

Model name Output

Voltage(VDC) Output

Current(A)

Max. Output

Power (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation

(%)

Avg. EFF (%) 25,50,75,100%

load

No load Power Consumption(W)

Measured at the

output ofGMPU18X-1 5~6 3.00–2.50 15 80 ±1 ±5 76.42 <0.3 5 GMPU18X-1-1 6~8 2.50-1.87 15 80 ±1 ±5 79.20 <0.3 7.5 GMPU18X-2 8~11 2.25-1.64 18.04 100 ±1 ±5 80.30 <0.3 9 GMPU18X-3 11~13 1.64-1.38 18.04 120 ±1 ±5 85.10 <0.1 12 GMPU18X-4 13~16 1.38-1.13 18.08 150 ±1 ±5 85.10 <0.1 15 GMPU18X-5 16~21 1.13-0.86 18.08 150 ±1 ±5 85.10 <0.1 18 GMPU18X-6 21~27 0.86-0.67 18.09 150 ±1 ±5 85.10 <0.1 24 GMPU18X-7 27~33 0.67-0.55 18.15 240 ±1 ±3 85.10 <0.1 28 GMPU18X-8 33~58 0.55-0.32 18.56 240 ±1 ±3 85.10 <0.1 48

Note: Note:

1. Weight: Approx

2. Optional output connectors (see page 81)

3. ENERGY STAR V Standard output cable: 5~13V: 20AWG / UL2468 / 4FT

13~58V: 22WG / UL2468 / 6FT

↑ <37>

FIG 1

58.5

FIG 2

58.5

FIG 3

58.5

10029.25

32.8

58.5

32.8

Derating

100%

20%

40%

60%70%

20 C10 C 30 C 40 C 50 CAmbient temperature( c)

Typical static characteristics

60 85 100 26490

100%

60%

80%

0

MPU30 30W Desktop series (FOR MEDICAL) Desktop power supply Features:

Universal input voltage Single output Optional output connectors High efficiency & reliability Compact package Optional input inlets Over voltage protection Over current protection Over Temperature protection Possess risk analysis report Meet 60601-1 3rd edition Two years limited warranty

SAFETY AGENCY APPROVALS: Specifications: MPU30series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.8~0.4A Max. Leakage current Class1:0.3mA/Class2:0.1mA Max.@240VAC/50Hz Output voltage See rating chart (±5% tolerance) Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Provided on outputs set at 112~132% of its nominal output voltage Over current protection All outputs protected to short circuit conditions Over Temperature protection 130 Activated Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40 Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Efficiency See rating chart Hold - up time 10msec minimum Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation ±5% variations from minimum to maximum output current. Insulation resistance 50Mohm minimum from input to output Inrush current 35AMPS@115 VAC or 65AMPS @ 230VAC at 25 cold start Withstand voltage 5656VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)EN60601-1-2:2007 (B)FCC PART 15 & PART 18 CLASS B Safety requirements Meets or Exceeds(A)UL: ES60601-1:2005 (B)CSA: C22.2 NO.60601-1:2008

(C)CB: IEC 60601-1:2005 (D)EN:EN60601-1:2006 Warranty 2 years

<38>

MPU30 30W Desktop series (FOR MEDICAL)

X=A IEC-320-C14 (FIG1) or B IEC-320-C8 (FIG2) or C IEC-320-C6 (FIG3) or D=MAINS CORD INPUT

Model name Output

Voltage(VDC)

Output

Current(A)

Max. Output

Power (W)

Ripple(mV)

Max.

Line

Regulation

(%)

Load

Regulation

(%)

Efficiency (%)

(min)

Measured at the

output of

MPU30X-0 3~5 5 25 30 ±1 ±8 65 3.3 MPU30X -1 5~6 5.00~4.17 25 30 ±1 ±8 68 5 MPU30X -1-1 6~8 4.17~3.13 25 40 ±1 ±4 70 7.5 MPU30X-2 8~11 3.75~2.73 30 50 ±1 ±4 74 9 MPU30X -3 11~13 2.73~2.30 30 50 ±1 ±3 75 12 MPU30X -4 13~16 2.30~1.88 30 60 ±1 ±3 75 15 MPU30X -5 16~21 1.88~1.43 30 70 ±1 ±2 76 18 MPU30X -6 21~27 1.43~1.11 30 80 ±1 ±2 77 24 MPU30X -7 27~33 1.11~0.90 30 100 ±1 ±2 78 28 MPU30X -8 33~48 0.90~0.63 30 100 ±1 ±2 78 48

Y=U American type or E European type AC power

Model name Output

Voltage(VDC)

Output

Current(A)

Max.

Output

Power (W)

Ripple(mV)

Max.

Line

Regulation (%)

Load

Regulation (%)

Efficiency (%)

(min)

Measured at the

output of

MPU30D -0-Y 3~5 5 25 30 ±1 ±8 65 3.3 MPU30D -1-Y 5~6 5.00~4.17 25 30 ±1 ±8 68 5 MPU30D -1-1-Y 6~8 4.17~3.13 25 40 ±1 ±4 70 7.5 MPU30D -2-Y 8~11 3.75~2.73 30 50 ±1 ±4 74 9 MPU30D -3-Y 11~13 2.73~2.30 30 50 ±1 ±3 75 12 MPU30D -4-Y 13~16 2.30~1.88 30 60 ±1 ±3 75 15 MPU30D -5-Y 16~21 1.88~1.43 30 70 ±1 ±2 76 18 MPU30D -6-Y 21~27 1.43~1.11 30 80 ±1 ±2 77 24 MPU30D -7-Y 27~33 1.11~0.90 30 100 ±1 ±2 78 28 MPU30D -8-Y 33~48 0.90~0.63 30 100 ±1 ±2 78 48 Note: (1) Weight: Approx 300~350g

(2)Optional output connectors (see page 81) <39>

FIG 1 FIG 2

MPU50 50W Desktop series ( FOR MEDICAL) Desktop power supply Features:

Universal input voltage Single output Optional output connectors High efficiency & reliability Compact package Over voltage protection Over current protection Over Temperature protection Possess risk analysis report Meet 60601-1 3rd edition Two years limited warranty

SAFETY AGENCY APPROVALS: Specifications: MPU50A,C series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 1.5~0.8A Max. Leakage current 0.3mA Max.@240VAC/50Hz Output voltage See rating chart (±5% tolerance) Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Provided on outputs set at 112~132% of its nominal output voltage Over current protection All outputs protected to short circuit conditions Over Temperature protection 130 Activated Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40 Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Efficiency See rating chart Hold - up time 10msec minimum Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation ±5% variations from minimum to maximum output current. Insulation resistance 50Mohm minimum from input to output Inrush current 65AMPS@115 VAC or 90AMPS @ 230VAC at 25 cold start Withstand voltage 5656VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)EN60601-1-2:2007 (B)FCC PART 15 & PART 18 CLASS B Safety requirements Meets or Exceeds(A)UL: ES60601-1:2005 (B)CSA: C22.2 NO.60601-1:2008

(C)CB: IEC 60601-1:2005 (D)EN:EN60601-1:2006

Warranty 2 years <40>

MPU50 50W Desktop series (FOR MEDICAL)

X= A (C14 FIG1) or C (C6 FIG2)

Model name Output

Voltage(VDC) Output

Current(A)

Max. Output

Power (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation

(%)

Efficiency (%) (min)

No load Power Consumption(W)

MPU50X-0 3~5 7.50 37.5 50 ±1 ±8 60 3.3 MPU50X -1 5~6 7.50~6.25 37.5 50 ±1 ±6 67 5 MPU50X -1-1 6~8 6.66~5.00 40 75 ±1 ±5 70 7.5 MPU50X-2 8~11 5.62~4.09 45 90 ±1 ±5 72 9 MPU50X -3 11~13 4.54~3.84 50 100 ±1 ±5 74 12 MPU50X -4 13~16 3.84~3.12 50 100 ±1 ±3 75 15 MPU50X -5 16~21 3.12~2.38 50 150 ±1 ±3 78 18 MPU50X -6 21~27 2.38~1.85 50 150 ±1 ±2 78 24 MPU50X -7 27~33 1.85~1.51 50 200 ±1 ±2 78 28 MPU50X -8 33~48 1.51~1.04 50 200 ±1 ±2 80 48 Note: (1) Weight: Approx 510~560g

(2)Optional output connectors (see page 81)

<41>

FIG 1 FIG 2

GMPU70 70W Desktop series (FOR MEDICAL) Desktop power supply Features:

Universal input voltage Meet ENERGY STAR V Single output Over voltage protection Over current protection Short circuit protection Means of patient protection design Low leakage current Output voltage 5~58VDC Possess risk analysis report Meet 60601-1 3rd edition Two years limited warranty

SAFETY AGENCY APPROVALS: Specifications: GMPSU70 series:

Input voltage 100~240VAC

Input frequency 50~60Hz

Input current 1.8~0.8A Max.

Leakage current <0.3mA

Output voltage See rating chart

Output current See rating chart

Output power range See rating chart

Ripple See rating chart

Over voltage protection Yes.<140% output voltage

Over current protection Yes.>120% output current, Auto-recover

Short protection Yes. Hiccup mode, Auto-recover

Temperature coefficient All output±0.04%/ maximum

Transient response Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature -20~+40.

Storage temperature -40~+85

Relative humidity 5% to 95% non-condensing

Derating Derated from 100% at + 40 linearly to 50% at 70

Efficiency See rating chart

Hold - up time 8mS min.

Line regulation ±1% maximum for any input voltage change between input voltage range

Load regulation ±5% variations from minimum to maximum output current.

Insulation resistance 50Mohm minimum from input to output

Inrush current 100AMPS @ 230VAC at 25 cold start

Withstand voltage 5656VDC from input to output

Mean time between failure 100,000 hours minimum at full load at 25 ambient

EMI requirements (A)EN60601-1-2:2007 (B)FCC PART 15 & PART 18 CLASS B

Safety requirements Meets or exceeds: (A) UL : ES60601-1:2005 (B) CSA:C22.2 NO. 60601-1:2008 (C) EN60601-1:2006 (D) IEC60601-1:2005

Warranty 2 years

<42>

GMPU70 70W Desktop series (FOR MEDICAL)

X=A (C14 FIG1) or C (C6 FIG2)

Model name Output

Voltage(VDC) Output

Current(A)

Max. Output

Power (W)

Ripple(mV)Max.

Line Regulation

(%)

Load Regulation (%)

Avg. EFF (%)No load Power

Consumption(W)

GMPU70X-1 5~6 7.50~6.36 37.5 200 ±1 ±5 83.4 5 GMPU70X-1-1 6~8 7.50~5.63 45 100 ±1 ±5 86.10 7.5 GMPU70X-2 8~11 7.50~5.46 60 120 ±1 ±5 87 9 GMPU70X-3 11~13 6.37~5.39 70 120 ±1 ±5 87 12 GMPU70X-4 13~16 5.39~4.38 70 120 ±1 ±5 87 15 GMPU70X-5 16~21 4.38~3.34 70 180 ±1 ±5 87 18 GMPU70X-6 21~27 3.34~2.60 70 180 ±1 ±5 87 24 GMPU70X-7 27~33 2.60~2.13 70 240 ±1 ±5 87 32 GMPU70X-8 33~58 2.13~1.22 70 240 ±1 ±5 87 48

Note: (1) Weight: Approx 370~375g (2) Optional output connectors (see page 81) (3) ENERGY STAR V standard output cable: 5~16V: UL1571 _14AWG_ 4FT 17~58V: SPT-1 _18AWG_ 6FT

<43>

GPSU06X-CC 6W Wall mount charger series

Plug-in power supply Features:

Universal input voltage Single output Pass LPS Optional output connectors Short circuit protection High efficiency & reliability Outputs are available at request Compact package One year limited warranty

SAFETY AGENCY APPROVALS: Specifications: GPSU06X-CC series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.2A Max. Leakage current 0.25mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes, Protected by Zener diode Over current protection Yes. Auto-recovery

Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection Yes. Hiccup mode ; Auto- recovery Temperature coefficient All output±0.04%/ maximum

Transient response Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature 0~+40.See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at+40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up/Hold up/Rise time Typical: 3000mS / 16mS / 50mS at full load. Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Or see rating chart Insulation resistance 50Mohm minimum from input to output Inrush current 30 AMPS@115 VAC;60AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11

(B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003 Safety requirements (A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1 Warranty 1year

<44>

GPSU06X-CC 6W Wall mount charger series

X=U American type (FIG1) or E European type (FIG2) or S 3pin Australian type (FIG3) Or SA 2pin Australian type (FIG4) or BS UK type (FIG5)

Model Output

Voltage(VDC)

Output

Current(A)

Max.

Output

Power

(W)

Ripple

(mV)

Max.

Line Regulation

(%)

Load

Regulation

(%)

Efficiency(%)(min) No load Power

Consumption(W)

Measured

at the

output of

GPSU06X-0-CC 3~5 1.33~0.80 4 50 ±1 ±10 45 <0.5 3.3 GPSU06X-1-CC 5~6 1.00~0.80 5 50 ±0.5 ±6 60 <0.5 5.6 GPSU06X-1-1-CC 6~8 1.00~0.75 6 80 ±0.5 ±5 65 <0.5 7.2 GPSU06X-2-CC 8~11 0.75~0.54 6 80 ±0.5 ±5 70 <0.5 8.4 GPSU06X-3-CC 11~13 0.54~0.46 6 100 ±0.5 ±4 74 <0.5 12 GPSU06X-4-CC 13~16 0.46~0.37 6 120 ±0.5 ±4 74 <0.5 13.8 GPSU06X-5-CC 16~21 0.37~0.28 6 150 ±0.5 ±4 74 <0.5 18 GPSU06X-6-CC 21~27 0.28~0.20 6 180 ±0.5 ±3 75 <0.5 24 GPSU06X-7-CC 27~33 0.20~0.18 6 200 ±0.5 ±3 75 <0.5 30 GPSU06X-8-CC 33~48 0.18~0.12 6 200 ±0.5 ±3 75 <0.5 48

Note: 1. Weight: Approx 70~100g 2. Optional output connectors (see page 81)

<45>

GPSU15X-CC 15W Wall mount charger series Plug-in power supply Features:

Universal input voltage Single output Pass LPS Optional output connectors Short circuit protection High efficiency & reliability Outputs are available at request Compact package One year limited warranty

SAFETY AGENCY APPROVALS: Specifications: GPSU15X-CC series : Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.5A Max. Leakage current 0.25mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes, Protected by Zener diode Over current protection Yes. Auto-recovery

Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection Yes. Hiccup mode ; Auto-recovery Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40.See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up / Hold up / Rise time Typical: 3000mS / 16mS / 50mS at full load. Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Insulation resistance 50Mohm. minimum form input to output Inrush current 20 AMPS@115 VAC ; 40AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11

(B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003 Safety requirements (A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1 Warranty 1year

<46>

GPSU15X-CC 15W Wall mount charger series

X=U American type (FIG1) or E European type (FIG2) or S 3pin Australian type (FIG3) or SA 2pin Australian type (FIG4) or BS UK type (FIG5)

Model name Output

Voltage(VDC)

Output

Current(A)

Max.

Output

Power

(W)

Ripple(mV)

Max.

Line

Regulation

(%)

Load

Regulation

(%)

Efficiency(%)(min) No load Power

Consumption(W)

Measured at

the output of

GPSU15X-1-CC 5~6 2.4~2.00 12 50 ±0.5 ±10 65 <0.5 5.6 GPSU15X-1-1-CC 6~8 2.00~1.50 12 80 ±0.5 ±5 74 <0.5 7.2 GPSU15X-2-CC 8~11 1.80~1.36 15 80 ±0.5 ±5 76 <0.5 8.4 GPSU15X-3-CC 11~13 1.36~1.15 15 100 ±0.5 ±5 76 <0.5 12 GPSU15X-4-CC 13~16 1.15~0.94 15 120 ±0.5 ±3 76 <0.5 13.8 GPSU15X-5-CC 16~21 0.94~0.72 15 120 ±0.5 ±3 77 <0.5 18 GPSU15X-6-CC 21~27 0.72~0.55 15 150 ±0.5 ±3 78 <0.5 24 GPSU15X-7-CC 27~33 0.55~0.45 15 240 ±0.5 ±2 80 <0.5 30 GPSU15X-8-CC 33~48 0.45~0.31 15 240 ±0.5 ±2 80 <0.5 48

Note: 1. Weight: Approx 70~150g

2. Optional output connectors (see page 81)

<47>

GPSU15X-CC 15W Desktop charger series Desktop power supply Features:

Universal input voltage Single output Pass LPS Optional output connectors Short circuit protection High efficiency & reliability Outputs are available at request Compact package One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: GPSU15X-CC series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.5A Max. Leakage current 0.25mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes, Protected by Zener diode Over current protection Yes. Auto-recovery

Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection Yes. Hiccup mode ; Auto- recovery Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40.See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Efficiency See rating chart Setup up / Hold up / Rise time Typical: 3000mS / 16mS / 50mS at full load. Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Or see rating chart Insulation resistance 50Mohn minimum from input to output Inrush current 20 AMPS@115 VAC ; 40AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11

(B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003 Safety requirements (A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1 Warranty 1year

<48>

GPSU15X-CC 15W Desktop charger series

X=A IEC-320-C14(FIG1) or B IEC-320-C8(FIG2) or C IEC-320-C6(FIG3) D= MAINS CORD INPUT

Model name Output

Voltage(VDC)

Output

Current(A)

Max.

Output

Power (W)

Ripple

(mV) Max.

Line

Regulation

(%)

Load

Regulation

(%)

Efficiency(%)(min) No load Power

Consumption(W)

Measured at

the output of

GPSU15X-1-CC 5~6 2.40~2.00 12 50 ±0.5 ±10 65 <0.5 5.6

GPSU15X-1-1-CC 6~8 2.00~1.50 12 80 ±0.5 ±5 74 <0.5 7.2

GPSU15X-2-CC 8~11 1.80~1.36 15 80 ±0.5 ±5 76 <0.5 8.4

GPSU15X-3-CC 11~13 1.36~1.15 15 100 ±0.5 ±5 76 <0.5 12

GPSU15X-4-CC 13~16 1.15~0.94 15 120 ±0.5 ±3 76 <0.5 13.8

GPSU15X-5-CC 16~21 0.94~0.72 15 120 ±0.5 ±3 77 <0.5 18

GPSU15X-6-CC 21~27 0.72~0.55 15 150 ±0.5 ±3 78 <0.5 24

GPSU15X-7-CC 27~33 0.55~0.45 15 240 ±0.5 ±2 80 <0.5 30

GPSU15X-8-CC 33~48 0.45~0.31 15 240 ±0.5 ±2 80 <0.5 48

Y=U American type or E European type

Model name Output

Voltage(VDC)

Output

Current(A)

Max.

Output

Power

(W)

Ripple (mV) Max.

Line

Regulation

(%)

Load

Regulation

(%)

Efficiency(%)(min) No load Power

Consumption(W)

Measured at

the output of

GPSU15D-1-Y-CC 5~6 2.4~2.00 12 50 ±0.5 ±10 65 <0.5 5.6

GPSU15D-1-1-Y-CC 6~8 2.00~1.50 12 80 ±0.5 ±5 74 <0.5 7.2

GPSU15D-2-Y-CC 8~11 1.80~1.36 15 80 ±0.5 ±5 76 <0.5 8.4

GPSU15D-3-Y-CC 11~13 1.36~1.15 15 100 ±0.5 ±5 76 <0.5 12

GPSU15D-4-Y-CC 13~16 1.15~0.94 15 120 ±0.5 ±3 76 <0.5 13.8

GPSU15D-5-Y-CC 16~21 0.94~0.72 15 120 ±0.5 ±3 77 <0.5 18

GPSU15D-6-Y-CC 21~27 0.72~0.55 15 150 ±0.5 ±3 78 <0.5 24

GPSU15D-7-Y-CC 27~33 0.55~0.45 15 240 ±0.5 ±2 80 <0.5 30

GPSU15D-8-Y-CC 33~48 0.45~0.31 15 240 ±0.5 ±2 80 <0.5 48

Note: 1. Weight: Approx 100~250g

2. Optional output connectors (see page 81) <49>

GPSU30X-CC 30W Desktop charger series (class2) Desktop power supply Features:

Universal input voltage Single output & Optional output connectors Short circuit protection Over voltage protection Over current protection Over temperature protection Constant Voltage & Constant Current 6~33 Vouch include reverse protection 2 color LED indicator for loading status One year limited warranty

SAFETY AGENCY APPROVALS: Specifications: GPSU30X-CC series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.7A Max. Leakage current 0.25mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection 110%~135% rated output voltage , pritected by Zener diode Over current protection Yes. Constant current protection 90%~110% constant limiting Output short protection Yes. Over thermal protection 140±10, auto-recovery by IC1 Tj Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40.See Derating chart Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Efficiency See rating chart Setup up / Hold up / Rise time 3000mS / 16mS / 50mS Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation ±5% variations from minimum to maximum output current. Or see rating chart Inrush current 15AMPS @ 115VAC or 40 AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11

(B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003 (C)VCCI J55014(H14):2001

Safety requirements (A)UL60950-1 (B)CSA C22.2 (C)TUV EN60950-1 Warranty 1year

<50>

GPSU30X-CC 30W Desktop charger series (class2)

X=B IEC-320-C8 (FIG1) or U American TYPE (FIG2) or E European Type (FIG3)

Model name Output

Voltage(VDC)

Output

Current(A)

Max. Output

Power (W)

Ripple(mV)

Max.

Line

Regulation

(%)

Load

Regulation

(%)

Efficiency(%)(min) No load Power

Consumption(W)

Measured at

the output of

*GPSU30X-0-CC 3~5 4 20 50 1 3.6~4.4 55 <1 4.2

*GPSU30X-1-CC 5~6 4.00~3.73 22.38 50 0.5 5~5.8 70 <1 5.6

GPSU30X-1-1-CC 6~8 3.60~2.70 21.60 80 0.5 6.5~7.5 70 <1 7.2

GPSU30X-2-CC 8~11 3.15~2.30 25.20 80 0.5 7.7~8.6 70 <1 8.4

GPSU30X-4-CC 13~16 2.30~1.87 30 100 0.5 13.5~14.5 78 <1 14.3

GPSU30X-5-CC 16~21 1.68~1.28 27 100 0.5 16~17 78 <1 16.8

GPSU30X-6-CC 27~33 1.11~0.90 30 150 0.5 27.1~28.8 80 <1 28.6

*NO LPS SAFETY

Note: 1. Weight: Approx 300~400g

2. Optional output connectors (see page 81)

<51>

GPSO15 open frame series

Features: Universal input voltage Meet ENERGY STAR V for 5~48VDC Short circuit Over voltage protections Over load protections Low leakage current Simple constant current (Option) One year limited warranty

SAFETY AGENCY APPROVALS: Application: General power

Specifications: GPSO15 series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.5A Max. Leakage current 0.25mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes, Protected by Zener diode Over current protection Yes. Auto-recovery

Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection Yes. Hiccup mode ; Auto- recovery Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40.See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up / Hold up / Rise time Typical: 3000mS / 16mS / 50mS at full load. Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Or see rating chart Insulation resistance 50Mohn minimum from input to output Inrush current 20 AMPS@115 VAC ; 40AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements CE Safety requirements Reference design: (A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1 Warranty 1 years Dimension(mm) 72x62x28 Weight(g) 70g

<52>

DA

NG

ER

HIG

H V

OL TA

GE

3.5

72

62

1.628 23

3.4

CN1 CN2

1 2 3 1 23.5

3.5

3.5

3.5

3.5

3.5

3.5

GPSO15 open frame series Mechanical Specification

AC input connector (CN1): Molex5273 series or equivalent Pin number Assignment Mating Housing Terminal

1 AC-L 2 N.C. 3 AC-N

Molex5058 or equivalent

Molex2478 or equivalent

DC output connector (CN2): Molex5273 series or equivalent

Pin number Assignment Mating Housing Terminal 1 -v 2 +v

Molex5195 or equivalent

Molex5194 or equivalent

Model name Output

Voltage(VDC) Output

Current (A) Max .Output Power (W)

Ripple(mV) Max.

Line Regulation (%)

Load Regulation (%)

Avg. EFF (%) 25,50,75,100% load

GPSO15-1 5~6 2.40~2.00 12 50 1 3 74.78

GPSO15-1-1 6~8 2.00~1.50 12 80 1 2 78.3

GPSO15-2 8~11 1.80~1.36 15 80 1 2 79.7

GPSO15-3 11~13 1.36~1.15 15 80 1 2 79.7

GPSO15-4 13~16 1.15~0.94 15 100 1 2 79.7

GPSO15-5 16~21 0.94~0.72 15 120 1 2 79.7

GPSO15-6 21~27 0.72~0.55 15 150 1 2 80

GPSO15-7 27~33 0.55~0.45 15 240 1 2 80

GPSO15-8 33~48 0.45~0.31 15 240 1 2 81

<53>

GPSO30 open frame series Features:

Universal input voltage No load power consumption<0.5W Vout above 7.5V Meet ENERGY STAR V Single output Short circuit protection Over voltage protection Over current protection One year limited warranty

SAFETY AGENCY APPROVALS:

Application: General power

Specifications: GPSO30 series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 1A Max. Leakage current Class1:3.5mA/Class2:0.25mA Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes. Over current protection Yes. Short circuit protection Yes. Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40. Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to50% at 70 Avg.Efficiency See rating chart Hold up time 10m/sec minimum Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation ±5% variations from minimum to maximum output current. Insulation resistance 50Mohm minimum from input to output Inrush current 60AMPS@115 VAC ; 80AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements CE Safety requirements Reference design (A)UL60950-1 (B) EN60950-1; IEC60950-1 (C) J60950 Warranty 1 year Dimension(mm) 128x40x29 Weight(g) 140g

<54>

GPSO30 open frame series Mechanical Specification

UNIT mm

AC input connector (CN1): Molex5237 series or equivalent

Pin number Assignment Mating Housing Terminal 1 AC-N 2 AC-L

Molex5058 or equivalent

Molex2478 or equivalent

DC output connector (CN2): Molex5237 series or equivalent

Pin number Assignment Mating Housing Terminal 1 Vo+ 2 Vo+ 3 Vo- 4 Vo-

Molex5195 or equivalent

Molex5194 or equivalent

Model name Output

Voltage(VDC) Output

Current (A) Max .Output Power (W)

Ripple(mV) Max.

Line Regulation (%)

Load Regulation (%)

Avg. EFF (%) 25,50,75,100% load

GPSU30-0 3~5 5 15~25 80 ±1 ±5 64

GPSO30-1 5~6 5.00~4.15 25 80 ±1 ±3 70

GPSU30-1-1 6~8 4.15~3.13 25 80 ±1 ±3 76

GPSO30-2 8~11 3.71~2.73 30 80 ±1 ±3 77

GPSO30-3 11~13 2.70~2.31 30 120 ±1 ±3 81

GPSO30-4 13~16 2.29~1.88 30 140 ±1 ±3 82

GPSO30-5 16~21 1.86~1.43 30 140 ±1 ±3 82

GPSO30-6 21~27 1.43~1.12 30 150 ±1 ±3 84

GPSO30-7 27~33 1.12~0.91 30 240 ±1 ±3 84

GPSO30-8 33~50 0.91~0.61 30 240 ±1 ±3 85

<55>

GPSO40 open frame series Features:

Universal input voltage No load power consumption<0.3W Meet ENERGY STAR V Single output Short circuit protection Over voltage protection Over current protection One year limited warranty

SAFETY AGENCY APPROVALS:

Application: General power

Specifications: GPSO40 series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 1A Max. Leakage current Class1:3.5mA/Class2:0.25mA Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes. Over current protection Yes. Short circuit protection Yes. Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40. Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to50% at 70 Avg. Efficiency See rating chart Hold up time 10m/sec minimum Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation ±5% variations from minimum to maximum output current. Insulation resistance 50Mohm minimum from input to output Inrush current 60AMPS@115 VAC ; 80AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements CE Safety requirements Reference design (A)UL60950-1 (B) EN60950-1; IEC60950-1 (C) J60950 Warranty 1 year Dimension(mm) 102x63x28.9 Weight(g) 140g

<56>

CN1

+-

CN2

102

63

3.3

3.3

3.3

4-3

27

1.5

28.9

123

12

3.3

3.3

3.3

3.3

3.3

FG

GPSO40 open frame series Mechanical Specification

UNIT mm AC input connector (CN1): Molex5237 series or equivalent

Pin number Assignment Mating Housing Terminal 1 AC-L 2 FG 3 AC-N

Molex5058 or equivalent

Molex2478 or equivalent

DC output connector (CN2): Molex5237 series or equivalent

Pin number Assignment Mating Housing Terminal 1 +v 2 -v

Molex5195 or equivalent

Molex5194 or equivalent

Model name Output

Voltage(VDC) Output

Current (A) Max .Output Power (W)

Ripple(mV) Max.

Line Regulation (%)

Load Regulation (%)

Avg. EFF (%) 25,50,75,100% load

GPSO40-1 5~6 5.00~4.17 25 350 1 3 79

GPSU40-1-1 6~8 5.00~3.75 30 200 1 3 81

GPSO40-2 8~11 4.38~3.18 35 120 1 3 82

GPSO40-3 11~13 3.64~3.08 40 130 1 2 85

GPSO40-4 13~16 3.08~2.50 40 250 1 2 85

GPSO40-5 16~21 2.82~2.15 45 250 1 2 86

GPSO40-6 21~27 2.15~1.67 45 300 1 2 86

GPSO40-7 27~33 1.67~1.37 45 300 1 2 86

GPSO40-8 33~50 1.37~0.90 45 400 1 2 86

<57>

LEO15 for LED power series

Features: Universal input voltage Short circuit Over voltage protections Over load protections Low leakage current Simple constant current (Option) One year limited warranty

SAFETY AGENCY APPROVALS:

Application: General power or LED power

Specifications: LEO15 series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.5A Max. Leakage current 0.25mA Max.@240VAC/50Hz Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating Chart Over voltage protection Yes, Protected by Zener diode Over current protection Yes. Auto-recovery

Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection Yes. Hiccup mode ; Auto- recovery Temperature coefficient All output±0.04%/ maximum Transient response Maximum excursion of 4% or better on all models.

Recovering to 1% of final value within 500uS after a 25% step load change Operating temperature 0~+40.See derating curve Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at + 40 linearly to 70% at 50 Avg. Efficiency See rating chart Setup up / Hold up / Rise time Typical: 3000mS / 16mS / 50mS at full load. Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation Typical±5% variations from minimum to maximum output current. Or see rating chart Insulation resistance 50Mohn minimum from input to output Inrush current 20 AMPS@115 VAC ; 40AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements CE Safety requirements Reference design: (A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1 Warranty 1 year Dimension(mm) 72x62x28 Weight(g) 70g

<58>

DA

NG

ER

HIG

H V

OL TA

GE

3.5

72

62

1.628 23

3.4

CN1 CN2

1 2 3 1 23.5

3.5

3.5

3.5

3.5

3.5

3.5

LEO15 for LED power series Mechanical Specification

UNIT: mm

AC input connector (CN1): Molex5273 series or equivalent Pin number Assignment Mating Housing Terminal

1 AC-l 2 N.C. 3 AC-N

Molex5058 or equivalent

Molex2478 or equivalent

DC output connector (CN2): Molex5273 series or equivalent

Pin number Assignment Mating Housing Terminal 1 -v 2 +v

Molex5195 or equivalent

Molex5194 or equivalent

Model name Output

Voltage(VDC) Output

Current (A) Max .Output Power (W)

Ripple(mV) Max.

Line Regulation (%)

Load Regulation (%)

EFF (%)

LEO15-1 5~6 2.40~2.00 12 50 1 ±10 65

LEO15-2 8~11 1.80~1.36 15 80 1 ±5 76

LEO15-3 11~13 1.36~1.15 15 100 1 ±5 76

LEO15-4 13~16 1.15~0.94 15 120 1 ±3 76

LEO15-5 16~21 0.94~0.72 15 120 1 ±3 77

LEO15-6 21~27 0.72~0.55 15 150 1 ±3 78

LEO15-7 27~33 0.55~0.45 15 240 1 ±2 80

LEO15-8 33~48 0.45~0.31 15 240 1 ±2 80

<59>

LEO40 for LED power series Universal input voltage Single output Short circuit protection High input power factor Over voltage protection Over current protection Optional output voltage adjustable function

Built-in constant current limiting with Adj. OCP level Built-in low input voltage cut off function Low input ATHD One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: LEO40 series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 1A Max. Input power factor ≧0.9 at 75~100% load Input total harmonic distortion <20% at 75~100% load Low input cut off voltage <70VAC +10/-20AC Leakage current <0.7mA Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes Over current protection Yes Short protection Yes Temperature coefficient All output±0.04%/ maximum

Operating temperature -20~+40 Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at+40 linearly to 50% at 70 Efficiency See rating chart Hold-up time No hold-up time Line regulation ±2% maximum for any input voltage change between input voltage range Load regulation ±5% variations from minimum to maximum output current. Insulation resistance 50Mohm minimum from input to output Inrush current 40 AMPS@115 VAC;80AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)EN55022 class B (B) FCC PART 15 B Safety requirements Design refer: UL1012 ; EN61347-1 EN61347-2-13 Warranty 1 year Dimension(mm) 163.5x54x25 Weight(g) 160g

<60>

LEO40 for LED power series

Mechanical Specification

Type1: AC input connector (CN1): Molex5273 series or equivalent

Pin number Assignment Mating Housing Terminal 1 AC-L 2 N.C. 3 AC-N

Molex5058 or equivalent

Molex2478 or equivalent

DC output connector (CN2): Molex5273 series or equivalent

Pin number Assignment Mating Housing Terminal 1 +v 2 +v 3 -v 4 -v

Molex5058 or equivalent

Molex2478 or equivalent

Type2: AC input connector (CN1): DINKLE EV508V-02P

Pin number Assignment Solid wire(AWG) Stranded wire (AWG / mm2)

1 AC-L 24~12 2 AC-N 24~12

DC output connector (CN2): DINKLE EV508V-02P

Pin number Assignment Solid wire(AWG) Stranded wire (AWG / mm2)

2 +V 24~12 3 -V 24~12

X=A (Class 1) or B (Class 2) Y=V→Output voltage adjustable A→Constant current level adjustable R→Output voltage and constant current level adjustable

Model name Output Voltage(VDC) Output Current(A) Max. Power(W) EFF(%) Ripple(V)

LEO40X-2-Y 8~11V 4.38~3.19A 35 76 2.5 LEO40X-3-Y 11~13V 3.64~3.08A 40 80 3 LEO40X-4-Y 13~16V 2.67~2.50A 40 82 3 LEO40X-5-Y 16~21V 2.50~1.91A 40 82 3.5 LEO40X-6-Y 21~27V 1.91~1.49A 40 82 3.5 LEO40X-7-Y 27~33V 1.49~1.22A 40 82 3.5 LEO40X-8-Y 33~40V 1.22~1.00A 40 82 3.5 LEO40X-9-Y 40~50V 1.00~0.84A 40 82 3.5

<61>

LE41 for LED power series Universal input voltage Single output Short circuit protection High input power factor (Active PFC) Over voltage protection Over current protection Output voltage and current adjustable function Constant voltage and current design Low input ATHD One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: LE41 series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 1A Max. Input power factor ≧0.9 at 75~100% load Input total harmonic distortion <20% at 75~100% load Leakage current <0.7mA Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes Over current protection Yes Short protection Yes Temperature coefficient All output±0.04%/ maximum Operating temperature -20~+40

Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at+40 linearly to 50% at 70 Efficiency See rating chart Hold-up time No hold-up time Line regulation ±2% maximum for any input voltage change between input voltage range Load regulation ±10% variations from minimum to maximum output current. Insulation resistance 50Mohm minimum from input to output Inrush current 40 AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)EN55015 class B (B) EN55022 class B (C)FCC PART 15 B Safety requirements Design refer: EN61347-1 ; EN61347-2-13 ; EN60950-1(CCN FKSZ2/8) ; UL8750 Warranty 1 year Dimension(mm) 236x45.8x30 Weight(g) 375g

<62>

LE41 for LED power series

Mechanical Specification UNIT: mm

Type1: AC input connector (CN1): DECA MB310-750M03 series or equivalent

Pin number Assignment Solid wire(AWG) Stranded wire (AWG / mm2)

1 AC-L 2 AC-N 3 AC-FG

26~12AWG

DC output connector (CN2): DECA MB310-750M02 series or equivalent

Pin number Assignment Solid wire(AWG) Stranded wire (AWG / mm2)

1 V- 2 V- 3 V+ 4 V+

26~12AGW

Type2: AC input connector (CN1): DINKLE 144RA-02P

Pin number Assignment Solid wire(AWG) Stranded wire (AWG / mm2)

1 AC-L 24~12 2 AC-N 24~12

DC output connector (CN2): DINKLE 144RA-04P

Pin number Assignment Solid wire(AWG) Stranded wire (AWG / mm2)

1 V- 24~12 2 V- 24~12 3 V+ 24~12 4 V+ 24~12

X=A (Class 1) or B (Class 2)

Model name Output Voltage(VDC) Output Current(A) Max. Power(W) EFF(%) Ripple(V)

LE41X-3 11~13V 3.64~3.08A 40 80 3 LE41X-4 13~16V 2.67~2.50A 40 82 3 LE41X-5 16~21V 2.50~1.91A 40 82 3.5 LE41X-6 21~27V 1.91~1.49A 40 82 3.5 LE41X-7 27~33V 1.49~1.22A 40 82 3.5 LE41X-8 33~40V 1.22~1.00A 40 82 3.5 LE41X-9 40~50V 1.00~0.84A 40 82 3.5

<63>

LE61 for LED power series Universal input voltage Single output Short circuit protection High input power factor (Active PFC) Over voltage protection Over current protection Output voltage and current adjustable function Constant voltage and current design Low input ATHD One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: LE61 series: Input voltage 100~240VAC Input frequency 50~60Hz Input current 1.2A Max. Input power factor ≧0.9 at 75~100% load Input total harmonic distortion <20% at 75~100% load Leakage current <0.7mA Output voltage See rating chart Output current See rating chart Output power range See rating chart Ripple See rating chart Over voltage protection Yes Over current protection Yes Short protection Yes Temperature coefficient All output±0.04%/ maximum

Operating temperature -20~+40 Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at+40 linearly to 50% at 70 Efficiency See rating chart Hold-up time No hold-up time Line regulation ±2% maximum for any input voltage change between input voltage range Load regulation ±5% variations from minimum to maximum output current. Insulation resistance 50Mohm minimum from input to output Inrush current 40 AMPS@115 VAC;80AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 100,000 hours minimum at full load at 25 ambient EMI requirements (A)EN55015 class B (B) EN55022 class B (C)FCC PART 15 B Safety requirements Design refer: EN61347-1 ; EN61347-2-13 ; EN60950-1(CCN FKSZ2/8) ; UL8750 Warranty 1 year Dimension(mm) 246x45.8x30 Weight(g) 452g

<64>

LE61 for LED power series

Mechanical Specification UNIT: mm

Type1: AC input connector (CN2): DECA MB310-750M03 series or equivalent

Pin number Assignment Solid wire(AWG) Stranded wire (AWG / mm2)

1 AC-L 2 AC-N 3 AC-FG

26~12AWG

DC output connector (CN1): DECA MB310-750M02 series or equivalent

Pin number Assignment Solid wire(AWG) Stranded wire (AWG / mm2)

1 N.C. 2 V- 3 V+ 4 N.C.

26~12AWG

Type2: AC input connector (CN2): DINKLE 144RA-02P

Pin number Assignment Solid wire(AWG) Stranded wire (AWG / mm2)

1 AC-L 24~12 2 AC-N 24~12

DC output connector (CN1): DINKLE 144RA-04P

Pin number Assignment Solid wire(AWG) Stranded wire (AWG / mm2)

1 V- 24~12 2 V- 24~12 3 V+ 24~12 4 V+ 24~12

X=A (Class 1) or B (Class 2)

Model name Output Voltage(VDC) Output Current(A) Max. Power(W) Efficiency(%)(min) Ripple(mV)

LE61X-3 11~13V 5A MAX 60 78 180 LE61X-4 13~16V 4.61~3.75A 60 78 180 LE61X-5 16~21V 3.75~2.86A 60 78 200 LE61X-6 21~27V 2.86~2.23A 60 80 200 LE61X-7 27~33V 2.23~1.82A 60 80 240 LE61X-8 33~40V 1.82~1.50A 60 82 260 LE61X-9 40~50V 1.50~1.20A 60 82 300

<65>

GUSB05 5VDC @ 1.0A USB Charger (ENERGY STAR V) Plug-in power supply Features:

Universal input voltage Meet ENERGY STAR V Standard USB (Type A) connector Short circuit protection Over voltage protection Over temperature protection

SAFETY AGENCY APPROVALS: Specifications: GUSB05 Input voltage 100~240VAC Input frequency 47~63Hz Input current 0.15A Max. Leakage current 0.25mA Max.@264VAC/50Hz Output voltage 5V Output current 1A Output power range 5W Ripple 80m Vp-p Over voltage protection Yes. Over current protection Yes. Short protection Yes. Over temperature protection U1 Tj<142 Operation temperature 0~+40 Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at+40°C linearly to 50% at 70°C

Efficiency 68.17% min Hold-up time 10m/sec minimum Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation ±5% variations from minimum to maximum output current Insulation resistance 50Mohm minimum from input to output Inrush current 35 AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 50,000 hours minimum at full load at 25 ambient EMI requirements FCC Safety requirements UL60950-1 ; CSA C22.2 Warranty 1year Weight 26g

<66>

GUSB05E 5VDC @ 1.0A USB Charger (ENERGY STAR V) Plug-in power supply Features:

Universal input voltage Meet Energy star V Standard USB (Type A)connector Short circuit protection Over voltage protection Over temperature protection One year limited warranty

SAFETY AGENCY APPROVALS: Specifications: GUSB05E Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.15A Max. Leakage current 0.25mA Max.@264VAC/50Hz Output voltage 5V Output current 1A Output power range 5W Ripple 120m Vp-p Over voltage protection Yes. Over current protection Yes. Short protection Yes. Over temperature protection U1 Tj<142 Operation temperature 0~+40 Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Derating Derated from 100% at+40°C linearly to 50% at 70°C

Efficiency 68.17% min Hold-up time 10m/sec minimum Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation ±5% variations from minimum to maximum output current Insulation resistance 50Mohm minimum from input to output Inrush current 35 AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 50,000 hours minimum at full load at 25 ambient EMI requirements CE: (EN55022; class B) (EN55024) Safety requirements EN60950-1 Warranty 1year Weight 32g

<67>

GUSB12 5VDC @ 2.1A USB Charger (ENERGY STAR V) Plug-in power supply Features:

Universal input voltage Meet ENERGY STAR V Standard USB (Type A)connector Option D+/D- define Short circuit protection Over voltage protection Over temperature protection One year limited warranty

SAFETY AGENCY APPROVALS: Specifications: GUSB12 Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.3A Max. Leakage current 0.25mA Max.@264VAC/50Hz Output voltage 5V Output current 2.1A Output power range 10.5W Ripple 160mVp-p MAX. At Vin:115VAC/60Hz ; 230VAC/50Hz Over voltage protection Yes. Over current protection Yes. Short protection Yes. Operation temperature 0~+40 Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Avg.Efficiency 73.75% min Hold-up time 8m/sec minimum Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation ±5% variations from minimum to maximum output current Insulation resistance 50Mohm minimum from input to output Inrush current 50 AMPS @ 115VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 50,000 hours minimum at full load at 25 ambient EMI requirements Meet LVD CE(EN55022 ; EN55024) ; FCC(FCC 47 CFR Part 15) Safety requirements Reference design to UL60950-1 ; CSA C22.2 Warranty 1year Weight 60g

<68>

+ -

4 3 2 1

USB Type A

GUSB12E 5VDC @ 2.1A USB Charger (ENERGY STAR V) Plug-in power supply Features:

Universal input voltage Meet ENERGY STAR V Standard USB (Type A)connector Option D+/D- define Short circuit protection Over voltage protection Over temperature protection One year limited warranty

SAFETY AGENCY APPROVALS: Specifications: GUSB12E Input voltage 100~240VAC Input frequency 50~60Hz Input current 0.3A Max. Leakage current 0.25mA Max.@264VAC/50Hz Output voltage 5V Output current 2.1A Output power range 10.5W Ripple 160mVp-p MAX. At Vin:115VAC/60Hz ; 230VAC/50Hz Over voltage protection Yes. Over current protection Yes. Short protection Yes. Operation temperature 0~+40 Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Avg.Efficiency 73.75% min Hold-up time 8m/sec minimum Line regulation ±1% maximum for any input voltage change between input voltage range Load regulation ±5% variations from minimum to maximum output current Insulation resistance 50Mohm minimum from input to output Inrush current 50 AMPS @ 230VAC at 25 cold start Withstand voltage 4242VDC from input to output Mean time between failure 50,000 hours minimum at full load at 25 ambient EMI requirements CE(EN55022 ; EN55024) ; FCC(FCC 47 CFR Part 15) Safety requirements Meet LVD Reference design to UL60950-1 ; CSA C22.2 ; EN60950-1 Warranty 1year Weight 65g

<69>

PSD03 5V/500mA USB DC TO DC series In car power supply (DC TO DC) Features:

Input voltage 11VDC to 28VDC Standard USB (Type A)connector Option D+/D- define High reliability High efficiency Compact package One year limited warranty

SAFETY AGENCY APPROVALS: UNT: mm

Specifications: PSD03 Input voltage 11 ~ 28VDC(Max. 32VDC) Input current 0.35A Max. Input Protection By 1.0A fuse Output voltage 5V Output current 500mA Output power range 2.5W Ripple 280mVp-p 20MHz band width. At Vin: 24VDC Over voltage protection Yes. Over current protection Yes. 0.85A Max. Output voltage drop. Operation temperature 0~+45 Short protection Yes. Storage temperature -40~+85 Relative humidity 5% to 95% non-condensing Efficiency 70% min Load regulation ±5% variations from minimum to maximum output current Mean time between failure 100,000 hours minimum at full load at 25 ambient EMC requirements CISPR 25 Warranty 1year Weight 32g

↑ <70>

PSD18 18W DC TO DC series (ISOLATED) In car power supply (DC TO DC) Features:

Wide input voltage 36VDC to 72VDC

Optional input and output connectors

High reliability

High efficiency

Compact package

One year limited warranty

UNIT: mm

Model name Output Voltage(VDC) Output Current(A) Maximum Output Power (W)

PSD18-1-I 5~6 VDC 3.00~2.50A 15W PSD18-1-1-I 6~8 VDC 2.50~1.88A 15W PSD18-2-I 8~11 VDC 2.25~1.64A 18W PSD18-3-I 11~13 VDC 1.64~1.38A 18W PSD18-4-I 13~16 VDC 1.38~1.13A 18W PSD18-5-I 16~21 VDC 1.13~0.86A 18W PSD18-6-I 21~27 VDC 0.86~0.67A 18W PSD18-7-I 27~33 VDC 0.67~0.55A 18W

Note: 1. Weight: Approx 150~250g

2. Optional output connectors (see page 81)

<71>

PSD25 18W DC TO DC series (ISOLATED) In car power supply (DC TO DC) Features:

Wide input voltage 11VDC to 26VDC

Optional input and output connectors

High reliability

High efficiency

Compact package

One year limited warranty UNIT: mm

Model name Output Voltage(VDC) Output Current(A) Maximum Output Power (W)

PSD25-0-I 3~5 VDC 3.33~2.00A 10W PSD25-1-I 5~6 VDC 2.70~2.25A 13.5W PSD25-1-1-I 6~8 VDC 2.40~1.80A 14.4W PSD25-2-I 8~11 VDC 2.13~1.55A 17.1W PSD25-3-I 11~13 VDC 1.55~1.38A 18W PSD25-4-I 13~16 VDC 1.38~1.12A 18W PSD25-5-I 16~21 VDC 1.12~0.85A 18W PSD25-6-I 21~27 VDC 0.85~0.66A 18W PSD25-7-I 27~33 VDC 0.66~0.54A 18W PSD25-8-I 33~48 VDC 0.54~0.37A 18W

Note: 1. Weight: Approx 150~250g

2. Optional output connectors (see page 81)

<72>

PSD40 36W DC TO DC series (ISOLATED) In car power supply (DC TO DC) Features:

Wide input voltage 11VDC to 26VDC

Optional input and output connectors

High reliability

High efficiency

Compact package

One year limited warranty

UNIT: mm

Model name Output Voltage(VDC) Output Current(A) Maximum Output Power (W) PSD40-0-I 3~5 VDC 5.00~3.00A 15W PSD40-1-I 5~6 VDC 4.50~3.75A 22.5W PSD40-1-1-I 6~8 VDC 5.00~3.75A 30W PSD40-2-I 8~11 VDC 4.27~3.10A 34.2W PSD40-3-I 11~13 VDC 3.27~2.76A 36W PSD40-4-I 13~16 VDC 2.76~2.25A 36W PSD40-5-I 16~21 VDC 2.25~1.71A 36W PSD40-6-I 21~27 VDC 1.71~1.33A 36W PSD40-7-I 27~33 VDC 1.33~1.09A 36W PSD40-8-I 33~48 VDC 0.75~0.75A 36W

Note: 1. Weight: Approx 200~250g

2. Optional output connectors (see page 81)

<73>

PSD12 8W DC TO DC series (NON-ISOLATED) In car power supply (DC TO DC) Features:

Input voltage 11VDC to 15VDC

Optional input and output connectors

High reliability

High efficiency

Compact package

One year limited warranty

Model name Output Voltage(VDC) Output Current(A) Maximum Output Power (W)

PSD12-1 5~6 VDC 1.00~0.83A 5W PSD12-1-1 6~8 VDC 1.00~0.75A 6W PSD12-2 8~10 VDC 1.00~0.72A 8W PSD12-4 13~16 VDC 0.61~0.50A 8W PSD12-5 16~21 VDC 0.50~0.38A 8W PSD12-6 21~27 VDC 0.38~0.29A 8W PSD12-7 27~33 VDC 0.29~0.24A 8W PSD12-8 33~48 VDC 0.24~0.16A 8W

Note: 1. Weight: Approx70~100g

2. Optional output connectors (see page 81)

<74>

PSD25 25W DC TO DC series (NON-ISOLATED) In car power supply (DC TO DC) Features:

Wide input voltage 11VDC to 26VDC for Model PSD25-0 to PSD25-2

Input voltage 11VDC to 15VDC for Model PSD25-5 to PSD25-8

Optional input and output connectors

High reliability

High efficiency

Compact package

One year limited warranty UNIT: mm

Model name Output Voltage(VDC) Output Current(A) Maximum Output Power (W)

PSD25-1 5~6 VDC 3.6~3.0A 18W PSD25-1-1 6~8 VDC 3.0~2.2A 18W PSD25-2 8~11 VDC 2.5~1.8A 20W PSD25-4 13~16 VDC 1.5~1.2A 20W PSD25-5 16~21 VDC 1.2~0.9A 20W PSD25-6 21~27 VDC 1.1~0.9A 25W PSD25-7 27~33 VDC 0.9~0.7A 25W PSD25-8 33~48 VDC 0.7~0.5A 25W

Note: 1. Weight: Approx200~250g

2. Optional output connectors (see page 81)

<75>

PSD40 40W DC TO DC series (NON-ISOLATED) In car power supply (DC TO DC) Features:

Wide input voltage 11VDC to 26VDC for Model PSD40-0 to PSD40-2

Input voltage 11VDC to 15VDC for Model PSD40-5 to PSD40-8

Optional input and output connectors

High reliability

High efficiency

Compact package

One year limited warranty UNIT: mm

Model name Output Voltage(VDC) Output Current(A) Maximum Output Power (W)

PSD40-1 5~6 VDC 5.0~4.1A 25W PSD40-1-1 6~8 VDC 5.0~3.7A 30W PSD40-2 8~11 VDC 4.3~3.1A 35W PSD40-4 13~16 VDC 2.9~2.3A 38W PSD40-5 16~21 VDC 2.5~1.9A 40W PSD40-6 21~27 VDC 1.6~1.4A 40W PSD40-7 27~33 VDC 1.4~1.2A 40W PSD40-8 33~48 VDC 1.2~0.8A 40W

Note: 1. Weight: Approx200~250g

2. Optional output connectors (see page 81)

<76> ↑

PSD60 60W DC TO DC Series (NON-ISOLATED) In car power supply (DC TO DC) Features:

Input voltage 11VDC to 15VDC

Optional input and output connectors

High reliability

High efficiency

Compact package

One year limited warranty

NIT: mm

Model name Output Voltage(VDC) Output Current(A) Maximum Output Power (W) PSD60-5 18~21 VDC 3.34~2.86A 60W PSD60-6 21~27 VDC 2.86~2.22A 60W PSD60-7 27~33 VDC 2.22~1.81A 60W

Note: 1. Weight: Approx200~250g

2. Optional output connectors (see page 81)

<77>

(0°-90°)

35.6

20

83.8

123.5

93.5

21

EJ13-123 In Car Power Extension Adapter With USB series In car power extension series Features:

Input voltage 12-24VDC Dual Standard USB (Type A)connectors One year limited warranty

UNT: mm

Specifications: EJ13-123 Input voltage 12 ~ 24VDC Input current 10A Max.(With 10A glass tube fuse)

USB Output 1A Max. when using 1 port only 0.5A Max. each port when using 2 ports

Material of socket Housing: ABS(UL94-HB) Inner contact: Nickel plated brass. Contact: Nickel plated metal.

Material of plug Housing: Phenolic (UL94V-1) Top contact: Nickel plated brass Contact: Nickel plated metal.

Dielectric strength 1000VAC / 1minule Insulation resistance 500VDC / 100MΩ Plug / Twin outlet sockets Twin outlet sockets with 0 ~ 90 degree. 4-positions adjustable plug USB Port Dual USB (Type A) USB sockets for charging mobile phones ; MP3 players & PDA’s Re-mark: Unavailable in UK market.

<78>

78.8

120

42HIGH MID 12V LOW

EJ13-149 In Car Power Extension Adapter With USB series In car power extension series Features:

Input voltage 12VDC(Max. 14VDC) Standard USB (Type A) connector Indicating different level of battery power Green LED light ring around sockets

for night time use One year limited warranty

UNT: mm

Battery analyzer features

BATTERY CHECKER

SITUATION

Low 12V MID HIGH

TURN OFF ENGINE OFF FOR

MINUTES

FOR BATTERY CAPCITY CHECK

START ENGINE FEW MINUTES

FOR

CHARGING SYSTEM CHECK

Very good Very good

Normal Normal

Weak Charging system is possibly abnormal

Too much discharge (The battery needs to be charged) Charging system is possibly abnormal

No capacity (Voltage is under 3V, replace battery)

Check your charging system

NOTE: THE ABOVE READINGS WOULD BE AFFECTED BY THE TEMPERATURE AND CAR USED CONDITION

<79>

Specifications: EJ13-149 Input voltage 12VDC Input current 10A Max. (With 10A glass tube fuse) USB Output 1A Max.

Material of socket Housing: ABS(UL94-HB) Inner contact: Nickel plated brass. Contact: Nickel plated metal.

W/extension cable ψ21mm Battery analyzer featured By 4 LED’s Dielectric strength 1000VAC / 1minule Insulation resistance 500VDC / 100MΩ Sockets LED light Green LED light ring around sockets USB Port USB sockets for charging mobile phones ; MP3 players and PDA’s Re-mark: Unavailable in UK market.

20

7.5

40.3

182.7

22.0

84

14.4

13.3

EJ13-175B In Car Power Extension Adapter With USB series In car power extension series Features:

Input voltage 12VDC Dual Standard USB (Type A)connectors Flexible neck for multi-positioning One year limited warranty

UNT: mm

Specifications: EJ13-175B Input voltage 12 VDC Input current 10A Max.(With 10A glass tube fuse)

USB Output 2A Max. when using 1 port only 1A Max. each port when using 2 ports

Material of socket Housing: ABS(UL94-HB) Inner contact: Nickel plated brass. Contact: Nickel plated metal.

Material of plug Housing: PBT (UL94-HB)) Top contact: Nickel plated brass Spring contact: Nickel plated spring steel.

Plug Flexible neck for multi-positioning Dielectric strength 1000VAC / 1minule Insulation resistance 500VDC / 100MΩ

USB Port Dual USB (Type A) USB sockets for charging mobile phones ; MP3 players and other devices

Re-mark: Unavailable in UK market. <80>

CONNECTOR (DC PLUG) LIST

<81>

ORDERING FORM