Varies - See Table Varies - See Table 990 Top Sheet Cover Width Brackets Typically @ 1167 Please Note: System is fire rated using Knauf Factoryclad 40 ECOSE insulation of minimum thickness 80mm with steel outer sheet only, to achieve 120 minutes Integrity, 15 minutes (min) Insulation which meets the requirements of Building Regulations Part B for external walls where fire attack is from inside the building and the wall is 1M or more from the boundary. System can be fire rated using Rockwool insulation of minimum thickness 120mm with steel outer sheet only, with liner stitched at 300mm centres, to achieve 120 minutes Integrity, 30 minutes (min) Insulation. Ensure roll edges are lapped/butted to ensure no gaps. *Fixings with an asterix are required on sheet ends and end laps only. * * Elite System 53 Bracket Height Insulation Thickness Insulation Value Overall System Depth U Value at 1.8M Centres 120mm 140mm 150mm 160mm 180mm 200mm 220mm 120mm 140mm 150mm*/160mm 160mm 180mm 200mm 220mm 0.040 0.040 0.040 0.040 0.040 0.040 0.040 140mm 160mm 170mm 180mm 200mm 220mm 240mm 0.37 0.31 0.29 0.27 0.24 0.22 0.20 170mm 180mm 0.040 190mm 0.26 240mm 280mm 300mm 0.040 0.040 0.040 260mm 300mm 320mm 0.18 0.15 0.14 260mm 0.040 280mm 0.17 240mm 280mm 300mm 260mm * Only available in Rockwool Cladding Roll TITLE: Elite System 53 DWG NO: E53 DRAWN: CD DATE: Jan 2020 CHECK: MP SCALE: NTS ELITE SYSTEMS To be read in conjunction with Elite System specification documents This draft drawing has been supplied by Euroclad Group Ltd for the purpose of guidance free of charge. It is a suggested typical detail and as such should not be assumed suitable for any specific project or application. No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing. Details are for illustration only and no liability is accepted. We reserve the right to change the details without notice.The drawing is copyright, it remains our property. Fax: +44 (0)2922 010 122 www.euroclad.com Tel: +44 (0)2922 010 101 1 of 15

Transcript of Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air...

Page 1: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

Varies - See Table

Varies - See Table

990 Top Sheet Cover Width

Brackets Typically @ 1167

Please Note:

System is fire rated using Knauf Factoryclad 40 ECOSE insulation of minimum thickness 80mm with steel outer sheet only, to achieve 120 minutes Integrity, 15 minutes

(min) Insulation which meets the requirements of Building Regulations Part B for external walls where fire attack is from inside the building and the wall is 1M or more

from the boundary.

System can be fire rated using Rockwool insulation of minimum thickness 120mm with steel outer sheet only, with liner stitched at 300mm centres, to achieve 120

minutes Integrity, 30 minutes (min) Insulation.

Ensure roll edges are lapped/butted to ensure no gaps.

*Fixings with an asterix are required on sheet ends and end laps only.

*

*

Elite System 53

Bracket Height

Insulation

Thickness

Insulation Value

Overall System

Depth

U Value at 1.8M

Centres

120mm

140mm

150mm

160mm

180mm

200mm

220mm

120mm

140mm

150mm*/160mm

160mm

180mm

200mm

220mm

0.040

0.040

0.040

0.040

0.040

0.040

0.040

140mm

160mm

170mm

180mm

200mm

220mm

240mm

0.37

0.31

0.29

0.27

0.24

0.22

0.20

170mm 180mm 0.040 190mm 0.26

240mm

280mm

300mm

0.040

0.040

0.040

260mm

300mm

320mm

0.18

0.15

0.14

260mm 0.040 280mm 0.17

240mm

280mm

300mm

260mm

* Only available in Rockwool Cladding Roll

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

1 of 15

Page 2: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

100

Min 60

ELITE SYSTEM 53 SIDE LAP DETAIL ELITE SYSTEM 53 END LAP DETAIL

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel

Euroclad EC 19-76-990 13.5_3_1

Sinusoidal 0.5mm Steel

50mm x 1mm butyl sealing tape

Quattro bar & bracket to required

depth typically @ 1167mm centres

Fixings to alternate troughs on

both intermediate supports,

sheet ends & end laps.

1 fixing must be through

the overlap trough

Euroclad EC 19-76-990 13.5_3_1

Sinusoidal 0.5mm Steel

Quattro bar & bracket to required

depth typically @ 1167mm centres

4mm Bead class A

butyl sealant

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel

COLOUR SIDE

COLOUR SIDE

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel Side Lap

EC 19-76-990 13.5_3_1

0.5 Steel Outer Sheet

Side lap detail

Please Note:

System is fire rated using Knauf Factoryclad 40 ECOSE insulation of minimum thickness

80mm with steel outer sheet only, to achieve 120 minutes Integrity, 15 minutes (min)

Insulation which meets the requirements of Building Regulations Part B for external walls

where fire attack is from inside the building and the wall is 1M or more from the boundary.

System can be fire rated using Rockwool insulation of minimum thickness 120mm with

steel outer sheet only, with liner stitched at 300mm centres, to achieve 120 minutes

Integrity, 30 minutes (min) Insulation.

Ensure roll edges are lapped/butted to ensure no gaps.

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

2 of 15

Page 3: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

76

990

23

19

19

R23

R22

63

COLOUR SIDE

COLOUR SIDE

COLOUR SIDE

COLOUR SIDE

167167

104

19

R

4

22

2

8

1

3

7

°

1

0

1000

18

EUROCLAD EC 19-167-1000 Liner 19_2L 0.4mm

LINER

EUROCLAD EC 19-76-990 13.5_3_1 SINUSOIDAL 0.5mm

EXTERNAL SHEET

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

3 of 15

Page 4: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

40

Brackets less than 260mm require

2 fixings diagonally opposite.

Brackets 260mm or more require

4 fixings.

< 260mm

≥ 260mm

40

33

34

60

59

VARIES D

EPEN

DIN

G

ON

BRACKET H

EIG

HT

VARIES D

EPEN

DIN

G

ON

BRACKET H

EIG

HT

SIDE ELEVATION

Maximum bar cantilever at free

ends is 300mm.

Spigot can fall anywhere between

two brackets.

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

4 of 15

Page 5: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

Class A Butyl Sealant to thickness

required to provide adequate air

sealing to masonry wall.

9 x 3mm Class A Butyl Sealant

Euroclad EC 19-76-990 13.5_5_1 Sinusoidal

0.5mm Steel

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel

Quattro bar & bracket to required

depth typically @ 1167mm centres

Quattro Spacer Rail

Insulation excluded for clarity

A range of mineral & glass wool insulations are available for different requirements

EUROCLAD ELITE SYSTEM 53 WALL CONSTRUCTION

Liner flashing sealed to masonry

Class A Butyl Sealant to thickness

required to provide adequate air

sealing to masonry wall.

Flashing stitched at max 450mm centres

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

5 of 15

Page 6: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

Euroclad EC 19-76-990 13.5_5_1 Sinusoidal

0.5mm Steel

Quattro bar & bracket to required

depth typically @ 1167mm centres

Fixings to alternate crowns on both intermediate

supports, sheet ends & end laps.

1 fixing must be through the overlap crown

9x3mm Mastic Sealant

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel

Internal Flashing fixed and sealed

to internal elements

9x3mm Mastic Sealant

Door detail by others

External Flashing

Insulation excluded for clarity

A range of mineral & glass wool insulations are available for different requirements

EUROCLAD ELITE SYSTEM 53 WALL CONSTRUCTION

Timber Packer

Sealant

9 x 3mm Class A Butyl Sealant

Flashing stitched at max 450mm centres

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

6 of 15

Page 7: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

External flashing

9 x 3mm Class A Butyl Sealant

Quattro bar & bracket to required

depth typically @ 1167mm centres

Quattro Spacer Rail

9 x 3mm Class A Butyl Sealant

Euroclad EC 19-76-990 13.5_5_1 Sinusoidal

0.5mm Steel

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel

Quattro Spacer Rail

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel

EUROCLAD ELITE SYSTEM 53 WALL CONSTRUCTION

Insulation excluded for clarity

A range of mineral & glass wool insulations are available for different requirements

9x3mm Mastic Sealant

Internal flashing fixed and sealed

to provide air tightness

Flashing stitched at max 450mm centres

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

7 of 15

Page 8: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel

Euroclad EC 19-76-990 13.5_5_1 Sinusoidal

0.5mm Steel

Drip Flashing

Drainage Point

Quattro bar & bracket to required

depth typically @ 1167mm centres

Large amount of sealant to make

allowance for imperfection in concrete and

ensure good airtightness. Seal may be achieved

at flashing or structural element such as ring beam,

depending on project specific details.

EUROCLAD ELITE SYSTEM 53 WALL CONSTRUCTION

Insulation excluded for clarity

A range of mineral & glass wool insulations are available for different requirements

Profile Filler

Liner Flashing fillers fixed and sealed to liners to

provide air tightness and vapour control

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

8 of 15

Page 9: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

9 x 3mm Class A Butyl Sealant

Euroclad EC 19-76-990 13.5_5_1 Sinusoidal

0.5mm Steel

Quattro bar & bracket to required

depth typically @ 1167mm centres

Euroclad EC 19-76-990 13.5_5_1 Sinusoidal

0.5mm Steel

9x3mm Mastic Sealant

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel

9x3mm Mastic Sealant

Quattro bar & bracket to required

depth typically @ 1167mm centres

Insulation excluded for clarity

A range of mineral & glass wool insulations are available for different requirements

EUROCLAD ELITE SYSTEM 53 WALL CONSTRUCTION

Internal flashing fixed and sealed

to provide air tightness

External Flashing

Stitched at max 450mm centres

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

9 of 15

Page 10: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

Large amount of sealant to make

allowance for imperfection in concrete and

ensure good airtightness. Seal may be achieved

at flashing or structural element such as ring beam,

depending on project specific details.

Closure Flashing

Quattro bar & bracket to required

depth typically @ 1167mm centres

EUROCLAD ELITE SYSTEM 53 WALL CONSTRUCTION

Insulation excluded for clarity

A range of mineral & glass wool insulations are available for different requirements

Euroclad EC 19-76-990 13.5_5_1 Sinusoidal

0.5mm Steel

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel

Profile Filler

Drip Flashing

Liner Flashing fillers fixed and sealed to liners to

provide air tightness and vapour control

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

10 of 15

Page 11: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

Euroclad EC 19-76-990 13.5_5_1 Sinusoidal

0.5mm Steel

Quattro bar & bracket to required

depth typically @ 1167mm centres

Fixings to alternate crowns on both intermediate

supports, sheet ends & end laps.

1 fixing must be through the overlap crown

9x3mm Mastic Sealant

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel

Internal Flashing fixed and sealed

to internal elements

9x3mm Mastic Sealant

Vehicle Access Door Detail by others

External Flashing

Packer by others

Sealant

9 x 3mm Class A Butyl Sealant

EUROCLAD ELITE SYSTEM 53 WALL CONSTRUCTION

Flashing stitched at max 450mm centres

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

11 of 15

Page 12: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

EUROCLAD ELITE SYSTEM 53 WALL CONSTRUCTION

40

Insulation excluded for clarity

A range of mineral & glass wool insulations are available for different requirements

Profile Filler

Euroclad EC 19-76-990 13.5_5_1 Sinusoidal

0.5mm Steel

Sealant

Drip Flashing

Closure Flashing

Liner Flashing fillers fixed and sealed to liners to

provide air tightness and vapour control

Quattro bar & bracket to required

depth typically @ 1167mm centres

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel

Packer by others

Vehicle Access Door Detail by others

Internal Flashing fixed and sealed

to internal elements

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

12 of 15

Page 13: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

40

Profile Filler

Euroclad EC 19-76-990 13.5_5_1 Sinusoidal

0.5mm Steel

Liner Flashing fillers fixed and sealed to liners to

provide air tightness and vapour control

Window Detail by others

Internal Flashing fixed and sealed

to internal elements

Sealant

Packer by others

Quattro bar & bracket to required

depth typically @ 1167mm centres

EUROCLAD ELITE SYSTEM 53 WALL CONSTRUCTION

Insulation excluded for clarity

A range of mineral & glass wool insulations are available for different requirements

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

13 of 15

Page 14: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

EUROCLAD ELITE SYSTEM 53 WALL CONSTRUCTION

Insulation excluded for clarity

A range of mineral & glass wool insulations are available for different requirements

40

Internal Flashing fixed and sealed

to internal elements

Quattro bar & bracket to required

depth typically @ 1167mm centres

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel

Packer by others

Window Detail by others

Profile Filler

Euroclad EC 19-76-990 13.5_5_1 Sinusoidal

0.5mm Steel

Sealant

Drip Flashing

Closure Flashing

Liner Flashing fillers fixed and sealed to liners to

provide air tightness and vapour control

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

14 of 15

Page 15: Elite System 53 - Euroclad Ltd...Class A Butyl Sealant to thickness required to provide adequate air sealing to masonry wall. 9 x 3mm Class A Butyl Sealant Euroclad EC 19-76-990 13.5_5_1

Euroclad EC 19-76-990 13.5_5_1 Sinusoidal

0.5mm Steel

Quattro bar & bracket to required

depth typically @ 1167mm centres

Fixings in alternate troughs on intermediate

supports and in all troughs at sheet ends & end laps

9x3mm Mastic Sealant

Euroclad EC 19-167-1000 Liner

19_2L 0.4mm Steel

Internal Flashing fixed and sealed

to internal elements

9x3mm Mastic Sealant

Window detail by others

External Flashing

Packer by others

Sealant

9 x 3mm Class A Butyl Sealant

EUROCLAD ELITE SYSTEM 53 WALL CONSTRUCTION

Insulation excluded for clarity

A range of mineral & glass wool insulations are available for different requirements

Flashing stitched at max 450mm centres

TITLE: Elite System 53

DWG NO: E53

DRAWN: CD

DATE: Jan 2020

CHECK: MP

SCALE: NTS

ELITE SYSTEMS

To be read in conjunction with

Elite System specification

documents

This draft drawing has been

supplied by Euroclad Group Ltd

for the purpose of guidance free

of charge. It is a suggested

typical detail and as such should

not be assumed suitable for any

specific project or application.

No responsibility is assumed for

errors or misinterpretations

resulting from the information

contained in the drawing. Details

are for illustration only and no

liability is accepted. We reserve

the right to change the details

without notice.The drawing is

copyright, it remains our

property.

Fax: +44 (0)2922 010 122

www.euroclad.com

Tel: +44 (0)2922 010 101

15 of 15