ElectroSurgicalMore ElectroSurgical Products...ElectroSurgical Pencils and Electrodes A Complete...

4
LITBRES001 R9 10/13/2020 ElectroSurgical Pencils and Electrodes A Complete Line of Superior Quality ElectroSurgical Produts

Transcript of ElectroSurgicalMore ElectroSurgical Products...ElectroSurgical Pencils and Electrodes A Complete...

Page 1: ElectroSurgicalMore ElectroSurgical Products...ElectroSurgical Pencils and Electrodes A Complete Line of Superior Quality ElectroSurgical Produts Product Number Size: 33 cm. 37 cm.

LITBRES001 R9 10/13/2020

ElectroSurgicalPencils and Electrodes

A Complete Line of Superior Quality

ElectroSurgicalProduts

Product Number

Size: 33 cm. 37 cm. 44 cm.

Product Number20080Hand Control

Foot Control

20145

20127 20111

L - Hook

Hand Control

Foot Control

20081 —

— ——

20138J - Hook

Hand Control

Foot Control

20082

20157 20146

20115 20147

L - Wire

Hand Control

Foot Control

20083 —

20148

20118 20149

J - Wire

Hand Control

Foot Control

20106

— — —

20158 20150

Curved Blade

Hand Control

Foot Control

20135

— —

20151

Straight Blade

Hand Control

Foot Control

20144

— 20152

20124 20153

Round Spatula

More ElectroSurgical Products

Laparoscopic Tips100% Tested When you select an Xodus Medical electrode, you are opting for industry leading Kynar insulation with everyprocedure. Because our electrodes are single-use, they are not subject to reprocessing, and therefore do not carry a risk of handling damage to the insulation. Compromised insulation may permit stray current, resulting in thermal necrosis of non-targeted tissue - which carries the potential for peritonitisor even death, if left unchecked. Every one of our electrodes is individually tested to ensure integrity against high-heat and chemical affects through a high-potential stress test. Additionally, the PTFE coatingdelivers consistent coagulation and resists flaking at high temperatures.

Page 2: ElectroSurgicalMore ElectroSurgical Products...ElectroSurgical Pencils and Electrodes A Complete Line of Superior Quality ElectroSurgical Produts Product Number Size: 33 cm. 37 cm.

Electrosurgical Pencils with PTFE Coated Electrodes21800 Button Switch w/Holster - 2.5” Blade Electrode21820 Button Switch w/Holster - 2.5” Blade Electrode Extended Insulation21850 Rocker Switch w/Holster - 2.5” Blade Electrode21870 Rocker Switch w/Holster - 2.5” Blade Electrode Extended Insulation21910 Button Switch w/Holster - 2.75” Needle Electrode21920 Rocker Switch w/Holster - 2.75” Needle Electrode21930 Button Switch w/Holster - 2.75” Needle Electrode Extended Insulation21940 Rocker Switch w/Holster - 2.75” Needle Electrode Extended Insulation21960 Button Switch w/Holster - 2.75” Blade Electrode21970 Rocker Switch w/Holster - 2.75” Blade Electrode21980 Button Switch w/Holster - 2.75” Blade Electrode Extended Insulation21990 Rocker Switch w/Holster - 2.75” Blade Electrode Extended Insulation

Pencils with Electrodes Standard Electrodes in PTFE

Standard Electrodes in Tungsten

More Options for Better Results

Cautery Pads

These pencils accommodate any surgeon preference with either push-buttonor rocker control. Superior components provide tactile feedback of the switches, safeguarding against accidental activation. Superior non-stick PTFE coating reduces eschar buildup, affording greater precision and enhanced patient safety. Xodus Medical pencils also perform well at lower power settings, minimizing thermal necrosis risk.

All pencils are available in stainless steel.See our website for the full listing of electrodes and holsters.

6.5” Needle PTFE Coated Product No:20023 50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

12 / Case

12 / Case

Product No:20062

Product No:20014

Product No:20015

Product No:20018

Product No:20012

Product No:20013

Product No:20057

Product No:20058

Product No:20055

Product No:20056

Product No:20010

Product No:20011

Product No:20072

Product No:20070

Product No:20017 50 /Case

6.5” Needle Extended Insulation Stainless Steel

6.5” Blade PTFE Coated

6.5” Blade Extended Insulation PTFE Coated

5” Ball PTFE Coated

4” Blade PTFE Coated

2.75” Blade PTFE Coated

2.75” Blade Extended Insulation PTFE Coated

2.5” Blade PTFE Coated

2.5” Blade Extended Insulation PTFE Coated

6.25” Bayonet Blade PTFE Coated

2.5 cm Tungsten Micro-Needle

4 cm Tungsten Micro-Needle

4” Blade Extended Insulation PTFE Coated

2.75” Needle PTFE Coated

2.75” Needle Extended Insulation PTFE Coated

30500 Safely and effectively cleans eschar buildup from stainless electrodes

20230 Grounding Pad without cord

20240 Grounding Pad with cord

Grounding Pads

Page 3: ElectroSurgicalMore ElectroSurgical Products...ElectroSurgical Pencils and Electrodes A Complete Line of Superior Quality ElectroSurgical Produts Product Number Size: 33 cm. 37 cm.

Electrosurgical Pencils with PTFE Coated Electrodes21800 Button Switch w/Holster - 2.5” Blade Electrode21820 Button Switch w/Holster - 2.5” Blade Electrode Extended Insulation21850 Rocker Switch w/Holster - 2.5” Blade Electrode21870 Rocker Switch w/Holster - 2.5” Blade Electrode Extended Insulation21910 Button Switch w/Holster - 2.75” Needle Electrode21920 Rocker Switch w/Holster - 2.75” Needle Electrode21930 Button Switch w/Holster - 2.75” Needle Electrode Extended Insulation21940 Rocker Switch w/Holster - 2.75” Needle Electrode Extended Insulation21960 Button Switch w/Holster - 2.75” Blade Electrode21970 Rocker Switch w/Holster - 2.75” Blade Electrode21980 Button Switch w/Holster - 2.75” Blade Electrode Extended Insulation21990 Rocker Switch w/Holster - 2.75” Blade Electrode Extended Insulation

Pencils with Electrodes Standard Electrodes in PTFE

Standard Electrodes in Tungsten

More Options for Better Results

Cautery Pads

These pencils accommodate any surgeon preference with either push-buttonor rocker control. Superior components provide tactile feedback of the switches, safeguarding against accidental activation. Superior non-stick PTFE coating reduces eschar buildup, affording greater precision and enhanced patient safety. Xodus Medical pencils also perform well at lower power settings, minimizing thermal necrosis risk.

All pencils are available in stainless steel.See our website for the full listing of electrodes and holsters.

6.5” Needle PTFE Coated Product No:20023 50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

50 /Case

12 / Case

12 / Case

Product No:20062

Product No:20014

Product No:20015

Product No:20018

Product No:20012

Product No:20013

Product No:20057

Product No:20058

Product No:20055

Product No:20056

Product No:20010

Product No:20011

Product No:20072

Product No:20070

Product No:20017 50 /Case

6.5” Needle Extended Insulation Stainless Steel

6.5” Blade PTFE Coated

6.5” Blade Extended Insulation PTFE Coated

5” Ball PTFE Coated

4” Blade PTFE Coated

2.75” Blade PTFE Coated

2.75” Blade Extended Insulation PTFE Coated

2.5” Blade PTFE Coated

2.5” Blade Extended Insulation PTFE Coated

6.25” Bayonet Blade PTFE Coated

2.5 cm Tungsten Micro-Needle

4 cm Tungsten Micro-Needle

4” Blade Extended Insulation PTFE Coated

2.75” Needle PTFE Coated

2.75” Needle Extended Insulation PTFE Coated

30500 Safely and effectively cleans eschar buildup from stainless electrodes

20230 Grounding Pad without cord

20240 Grounding Pad with cord

Grounding Pads

Page 4: ElectroSurgicalMore ElectroSurgical Products...ElectroSurgical Pencils and Electrodes A Complete Line of Superior Quality ElectroSurgical Produts Product Number Size: 33 cm. 37 cm.

LITBRES001 R9 10/13/2020

ElectroSurgicalPencils and Electrodes

A Complete Line of Superior Quality

ElectroSurgicalProduts

Product Number

Size: 33 cm. 37 cm. 44 cm.

Product Number20080Hand Control

Foot Control

20145

20127 20111

L - Hook

Hand Control

Foot Control

20081 —

— ——

20138J - Hook

Hand Control

Foot Control

20082

20157 20146

20115 20147

L - Wire

Hand Control

Foot Control

20083 —

20148

20118 20149

J - Wire

Hand Control

Foot Control

20106

— — —

20158 20150

Curved Blade

Hand Control

Foot Control

20135

— —

20151

Straight Blade

Hand Control

Foot Control

20144

— 20152

20124 20153

Round Spatula

More ElectroSurgical Products

Laparoscopic Tips100% Tested When you select an Xodus Medical electrode, you are opting for industry leading Kynar insulation with everyprocedure. Because our electrodes are single-use, they are not subject to reprocessing, and therefore do not carry a risk of handling damage to the insulation. Compromised insulation may permit stray current, resulting in thermal necrosis of non-targeted tissue - which carries the potential for peritonitisor even death, if left unchecked. Every one of our electrodes is individually tested to ensure integrity against high-heat and chemical affects through a high-potential stress test. Additionally, the PTFE coatingdelivers consistent coagulation and resists flaking at high temperatures.