Electronic visualization laboratory, university of illinois at chicago Camera Based Automatic...

6
electronic visualization laboratory, university of illinois a Camera Based Automatic Calibration for the Varrier™ System Jinghua Ge, Dan Sandin, Tom Peterka, Todd Margolis, Tom DeFanti Electronic Visualization Laboratory, University of Illinois at Chicago

Transcript of Electronic visualization laboratory, university of illinois at chicago Camera Based Automatic...

Page 1: Electronic visualization laboratory, university of illinois at chicago Camera Based Automatic Calibration for the Varrier™ System Jinghua Ge, Dan Sandin,

electronic visualization laboratory, university of illinois at chicago

Camera Based Automatic Calibration for the Varrier™ System

Jinghua Ge, Dan Sandin, Tom Peterka, Todd Margolis, Tom DeFanti

Electronic Visualization Laboratory, University of Illinois at Chicago

Page 2: Electronic visualization laboratory, university of illinois at chicago Camera Based Automatic Calibration for the Varrier™ System Jinghua Ge, Dan Sandin,

electronic visualization laboratory, university of illinois at chicago

Introduction of Varrier

Varrier is a head-tracked, 35 panel tiled autostereoscopic VR display

Combination of physical and virtual linescreens to achieve autostereo

Virtual linescreen registration parameters:

Pitch, z rotation, optical thickness, x shift

Page 3: Electronic visualization laboratory, university of illinois at chicago Camera Based Automatic Calibration for the Varrier™ System Jinghua Ge, Dan Sandin,

electronic visualization laboratory, university of illinois at chicago

Camera automated calibration

Two video cameras simulate human eyes

Goal:

left eye sees left image,

right eye sees right image

Calibration Patterns:

Color pattern: left eye red, right eye blue

Cross bar pattern: white cross bars, left eye 45º , right eye -45º

Page 4: Electronic visualization laboratory, university of illinois at chicago Camera Based Automatic Calibration for the Varrier™ System Jinghua Ge, Dan Sandin,

electronic visualization laboratory, university of illinois at chicago

Calibration Algorithms

• Heuristic rough tune– Color pattern enhances

moire bars– Register rotaton until moire

bar parallel to linescreen– Register optical thickness

until no bar in at least one eye image

– Register shift until left eye see red, right eye see blue

Page 5: Electronic visualization laboratory, university of illinois at chicago Camera Based Automatic Calibration for the Varrier™ System Jinghua Ge, Dan Sandin,

electronic visualization laboratory, university of illinois at chicago

Calibration Algorithms (cond’)

• Adaptive fine tune– Cross bar pattern enhances brightness/ghost– 2D searching for maximum brightness-ghost– Multiple fine tune get better precision

Page 6: Electronic visualization laboratory, university of illinois at chicago Camera Based Automatic Calibration for the Varrier™ System Jinghua Ge, Dan Sandin,

electronic visualization laboratory, university of illinois at chicago

Performance and Conclusion

• Heuristic rough tune achieve close result very fast– Usually in less than 70 steps

• Multiple adaptive fine tune get best parameter set in high precision– Usually less than 100 steps

• Registration runs at 3fps. One minute for each screen.

• One on-axis registration works for free on-axis movement