ELECTRICAL MACHINES-II LAB III/IV B.Tech-I SEMESTER ...
Transcript of ELECTRICAL MACHINES-II LAB III/IV B.Tech-I SEMESTER ...
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 1
ELECTRICAL MACHINES-II LAB
III/IV B.Tech-I SEMESTER
STUDENT OBSERVATION RECORD
DEPARTMENT
OF
ELECTRICAL AND ELECTRONICS ENGINEERING
VEMU INSTITUTE OF TECHNOLOGY::P.KOTHAKOTA
NEAR PAKALA, CHITTOOR-517112 (Approved by AICTE, New Delhi & Affiliated to JNTUA, Anantapuramu)
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 2
VEMU INSTITUTE OF TECHNOLOGY
DEPT.OF ELECTRICAL AND ELECTRONICS ENGINEERING
VISION OF THE INSTITUTE
To be a premier institute for professional education producing dynamic and vibrant force
of technocrats with competent skills, innovative ideas and leadership qualities to serve the
society with ethical and benevolent approach.
MISSION OF THE INSTITUTE
To create a learning environment with state-of-the art infrastructure, well equipped
laboratories, research facilities and qualified senior faculty to impart high quality
technical education.
To facilitate the learners to foster innovative ideas, inculcate competent research and
consultancy skills through Industry-Institute Interaction.
To develop hard work, honesty, leadership qualities and sense of direction in rural youth
by providing value based education.
VISION OF THE DEPARTMENT
To produce professionally deft and intellectually adept Electrical and Electronics
Engineers and equip them with the latest technological skills, research & consultancy
competencies along with social responsibility, ethics, Lifelong Learning and leadership
qualities.
MISSION OF THE DEPARTMENT
To produce competent Electrical and Electronics Engineers with strong core knowledge,
design experience & exposure to research by providing quality teaching and learning
environment.
To train the students in emerging technologies through state - of - the art laboratories and
thus bridge the gap between Industry and academia.
To inculcate learners with interpersonal skills, team work, social values, leadership
qualities and professional ethics for a holistic engineering professional practice through
value based education.
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 3
ROGRAM EDUCATIONAL OBJECTIVES(PEOs)
Programme Educational Objectives (PEOs) of B.Tech (Electrical and Electronics
Engineering) program are:
Within few years of graduation, the graduates will
PEO 1: Provide sound foundation in mathematics, science and engineering fundamentals to
analyze, formulate and solve complex engineering problems.
PEO 2: Have multi-disciplinary Knowledge and innovative skills to design and develop Electrical
& Electronics products and allied systems.
PEO 3: Acquire the latest technological skills and motivation to pursue higher studies leading to
research.
PEO 4: Possess good communication skills, team spirit, ethics, modern tools usage and the life-
long learning needed for a successful professional career.
PROGRAM OUTCOMES (POs)
PO-1 Engineering knowledge: Apply the knowledge of mathematics, science, engineering
fundamentals, and an engineering specialization to the solution of complex engineering
problems.
PO-2 Problem analysis: Identify, formulate, review research literature, and analyze
complex engineering problems reaching substantiated conclusions using first principles
of mathematics, natural sciences, and engineering sciences.
PO-3 Design/development of solutions: Design solutions for complex engineering
problems and design system components or processes that meet the specified needs
with appropriate consideration for the public health and safety, and the cultural,
societal, and environmental considerations.
PO-4 Conduct investigations of complex problems: Use research-based knowledge and
research methods including design of experiments, analysis and interpretation of data,
and synthesis of the information to provide valid conclusions.
PO-5 Modern tool usage: Create, select, and apply appropriate techniques, resources, and
modern engineering and IT tools including prediction and modeling to complex
engineering activities with an understanding of the limitations.
PO-6 The engineer and society: Apply reasoning informed by the contextual knowledge to
assess societal, health, safety, legal and cultural issues and the consequent
responsibilities relevant to the professional engineering practice.
PO-7 Environment and sustainability: Understand the impact of the professional
engineering solutions in societal and environmental contexts, and demonstrate the
knowledge of, and need for sustainable development.
PO-8 Ethics: Apply ethical principles and commit to professional ethics and responsibilities
and norms of the engineering practice.
PO-9 Individual and team work: Function effectively as an individual, and as a member or
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 4
leader in diverse teams, and in multidisciplinary settings.
PO-10 Communication: Communicate effectively on complex engineering activities with the
engineering community and with society at large, such as, being able to comprehend
and write effective reports and design documentation, make effective presentations,
and give and receive clear instructions.
PO-11 Project management and finance: Demonstrate knowledge and understanding of the
engineering and management principles and apply these to one’s own work, as a
member and leader in a team, to manage projects and in multidisciplinary
environments.
PO-12 Life-long learning: Recognize the need for, and have the preparation and ability to
engage in independent and life-long learning in the broadest context of technological
change.
PROGRAM SPECIFIC OUTCOMES (PSOs)
On completion of the B.Tech. (Electrical and Electronics Engineering) degree, the
graduates will be able to
PSO-1: Higher Education: Apply the fundamental knowledge of Mathematics, Science,
Electrical and Electronics Engineering to pursue higher education in the areas of Electrical
Circuits, Electrical Machines, Electrical Drives, Power Electronics, Control Systems and Power
Systems.
PSO-2: Employment: Get employed in Public/Private sectors by applying the knowledge in the
domains of design and operation of Electronic Systems, Microprocessor based control systems,
Power systems, Energy auditing etc.
Electrical Machines-II Lab
Course Outcomes
C318.1
Analyze the performance of induction motor by conducting no-load and blocked rotor
tests.
C318.2 Analyze the performance of induction motor by direct load test.
C318.3 Analyze the performance of induction motor by direct load test.
C318.4 Apply O.C and S.C tests of a transformer for the losses and efficiency.
C318.5 Determine the direct and quadrature axis reactances by conducting slip test.
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 5
VEMU INSTITUTE OF TECHNOLOGY::P.KOTHAKOTA
NEAR PAKALA, CHITTOOR-517112 (Approved by AICTE, New Delhi & Affiliated to JNTUA, Anantapuramu)
ELECTRICAL MACHINES-II LABORATORY(15A02506)
Name:__________________________________
H.T.No:_________________________________
Year/Semester:__________________________
Department of Electrical and Electronics Engineering
VEMU INSTITUTE OF TECHNOLOGY::P.KOTHAKOTA
NEAR PAKALA, CHITTOOR-517112 (Approved by AICTE, New Delhi & Affiliated to JNTUA, Anantapuramu)
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 6
JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY ANANTAPUR
B. Tech III-I Sem. (EEE)
L T P C
0 0 4 2
15A02506 ELECTRICAL MACHINES LABORATORY – II
Course Objective:
Synchronous Motors, and evaluate their performance characteristics.
The following experiments are required to be conducted as compulsory
experiments:
1. O.C. & S.C. Tests on Single phase Transformer.
2. Sumpner‟s Test on a Pair of identical Single Phase Transformers
3. Scott Connection of Transformers
4. No-Load & Blocked Rotor Tests on Three Phase Induction Motor
5. Regulation of Three –Phase Alternator by Synchronous Impedance & M.M.F.
Methods
6. V and Inverted V Curves of 3 Phase Synchronous Motor.
7. Equivalent Circuit of Single Phase Induction Motor
8. Determination of Xd and Xq of Salient Pole Synchronous Machine
In addition to the above eight experiments, at least any two of the following
experiments are required to be conducted:
1. Parallel Operation of Single Phase Transformers
2. Separation of Core Losses of Single Phase Transformer
3. Brake Test on Three Phase Induction Motor
4. Regulation of Three-Phase Alternator by Z.P.F. and A.S.A Methods
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 7
CONTENTS
ELECTRICAL MACHINES-II LAB
S.NO. NAME OF THE EXPERIMENT PAGE NO.
1 LOAD TEST ON 3-Ø INDUCTION MOTOR
1
2 O.C & S.C TESTS ON 1-Ø TRANSFORMER 4
3 NO-LOAD & BLOCKED ROTOR TESTS ON 3-Ø
INDUCTION MOTOR 9
4 PARALLEL OPERATION OF SINGLE PHASE
TRANSFORMERS 12
5 SCOTT CONNECTION OF TRANSFORMERS 17
6 EQUIVALENT CIRCUIT OF A 1- Ø INDUCTION
MOTOR 20
7 SUMPNER’S TEST 24
8 REGULATION OF 3-Φ ALTERNATOR BY
SYNCHRONOUS IMPEDANCE METHOD 28
9 DETERMINATION OF Xd & Xq OF SALIENT POLE
SYNCHRONOUS MACHINE 33
10 V – -CURVES OF A THREE PHASE
SYNCHRONOUS MOTOR 36
Additional Experiments
11
12
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 8
GENERAL INSTRUCTIONS FOR LABORATORY CLASSES
DO‘S
1. Without Prior permission do not enter into the Laboratory.
2. While entering into the LAB students should wear their ID cards.
3. The Students should come with proper uniform.
4. Students should sign in the LOGIN REGISTER before entering into the laboratory.
5. Students should come with observation and record note book to the laboratory.
6. Students should maintain silence inside the laboratory.
7. Circuit connections must be checked by the lab-in charge before switching the supply
DONT‘S
8. Students bringing the bags inside the laboratory..
9. Students wearing slippers/shoes insides the laboratory.
10. Students scribbling on the desk and mishandling the chairs.
11. Students using mobile phones inside the laboratory.
12. Students making noise inside the laboratory.
13. Students mishandle the devices.
14. Students write anything on the devices
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 9
SCHEME OF EVALUATION
S.No Experiment name Date
Marks Awarded Total
30(M) Record
(10M)
Observation
(10M)
VivaVoce
(5M)
Attendance
(5M)
1 Load test on 3-ø induction
motor
2 O.C & S.C tests on 1-ø
transformer
3 No-load & blocked rotor tests
on 3-ø induction motor
4 Parallel operation of single
phase transformers
5 Scott connection of
transformers
6 Equivalent circuit of a 1- ø
induction motor
7 Sumpner’s test
8 Regulation of 3-φ alternator by
synchronous impedance method
9
Determination of xd & xq of
salient pole synchronous
machine
10
V – curves and inverted V-
curves of a three phase
synchronous motor
Signature of Lab In-charge
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 10
Exp. No.: Date:
LOAD TEST ON 3-Ø INDUCTION MOTOR
Aim:
To conduct load test on the given 3-Φ induction motor and to plot its performance characteristics.
Apparatus:
S. No. Name of the Equipment Range Type Quantity
1 3- Ø Variac 415V/(0-470)V - 1
2 Ammeter (0-10)A MI 1
3 Voltmeter (0-600)V MI 1
4 Wattmeter 600V/10A UPF 2
5 Tachometer (0-10000)rpm Digital 1
6 Connecting Wires - - Required Some
Circuit Diagram:
Name plate details:
Precautions:
1. 3-Ø Variac should be in minimum position.
2. Avoid loose connections
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 11
Procedure:
1. Connect the circuit as shown in circuit diagram.
2. Observing the precautions close the TPST Switch and switch ON 440V A.C supply.
3. Apply the rated voltage to the stator windings of 3-Ø Induction Motor with the help of
3-Φ Auto-transformer.
4. Note down the readings of wattmeter, ammeter and voltmeter on no-load.
5. Load the Induction Motor in steps using the brake-drum arrangement. At each step note
down the readings of all meters, speed and spring balance readings till full load current.
6. Gradually releasing the load and stop the motor.
7. Observing the precautions switch OFF the supply
Tabular Column:
S.
No.
Line
voltage
VL
(V)
Line
current
IL
(A)
Wattmeter
Readings
(W)
Speed
N
(rpm)
Spring Balance
Reading %Slip
Power
Factor
Torque
(N-m)
Input
power
(w)
Output
(W)
ŋ
(%)
W1
(W)
W2
(W) S1 S2 S1~S2
1
2
3
4
5
6
Formulae:
Torque, Tsh = 9.81 (S1 ~ S2) R N-m
Input Power, Winp = W1 + W2 W
Output Power, Wout = (2 π NTsh)/60 W
%Slip = Ns – N X 100
Ns
cosØ = Wout
√3 VL IL
Efficiency = %ŋ = (Output/Input) X 100
Model Graph:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 12
Calculations:
Result:
Viva Voce Questions:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 13
1. What is meant by direct loading and indirect loading?
2. What are the limitations of direct loading?
3. What are the different types of induction motors?
4. Which type of induction motor has high starting torque?
5. Define slip.
6. Define the rated speed.
7. How the torque is developed in an induction motor.
8. How the torque and speed are related and draw the torque -slip characteristics.
9. Define synchronous speed.
10. Define synchronous watt.
Exp. No.: Date:
O.C & S.C TESTS ON 1-Ø TRANSFORMER
Aim: a) To determine the efficiency and regulation of 1- Ø transformer by conducting no-load
and S.C Test.
b) To draw the equivalent circuit of 1- Ø transformer referred to L.V side as well as H.V
side.
Apparatus:
S. No. Name of the Equipment Range Type Quantity
1 1- Ø Variac 230V/(0-270)V, 10A - 1
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 14
2 1- Ø Transformer 115V/230V, 2kVA Core 1
3 Ammeter (0-10)A MI 1
(0-2)A MI 1
4 Voltmeter (0-150)V MI 1
(0-30)V MI 1
5 Wattmeter 150V/2A LPF 1
75V/10A UPF 1
6 Connecting Wires - - Required Some
Circuit Diagram:
O.C Test:
S.C Test:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 15
Precautions:
1. Connections should be made tight.
2. 1- Ø Variac should be in minimum position.
Procedure:
1. Connect the circuit as shown in circuit diagram for O.C test.
2. Observing the precautions switch ON 1- Ø A.C supply and by using the 1-Ф variac apply
the rated voltage of the primary of the transformer.
3. Note down all the meter readings. Here wattmeter reading gives iron loss.
4. Observing the precautions switch OFF the supply.
5. Connect the circuit as shown in circuit diagram for S.C test.
6. Observing the precautions switch ON 1- Ø A.C supply and by using the 1-Ф variac apply
the rated current to the transformer. (Rated power of the transformer/Voltage of primary of
transformer)
7. Note down all the meter readings, here wattmeter reading gives full-load copper loss.
8. Observing the precautions switch OFF the supply.
Tabular Columns:
O.C Test: S.C Test:
Vo (V) Io (A) Wo = W X M.F (W)
VSC (V) ISC (A) WSC = W X M.F (W)
Efficiencies at different loads and power factor:
cosθ = cosθ =
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 16
Load
Cu Loss
(W)
Output
(W)
Input
(W)
Efficiency
(%η)
Cu
Loss
(W)
Output
(W)
Input
(W)
Efficiency
(%η)
Lagging Power Factor Leading Power Factor
Power Factor % Regulation Power Factor % Regulation
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 17
Model Calculations:
Let the transformer be the step-down transformer (O.C Test)
Primary is H.V side and secondary is L.V side
Ro=V1/Iw (Ω) where Iw=IocosФo
Xo=V1/Iµ (Ω) where Iw=IocosФo
Ro1=WSC/ISC2 (Ω)
ZO1=VSC/ISC
Xo1=√( ZO12 - Ro1
2)
Ro2=K2 Ro1
Xo2=K2 Xo1
where,
K=V2/V1=Transformation Ratio
Calculations to find efficiency:
For example, at 1/4th full load,
Copper Losses=WSC x (1/4)2 (w)
where, WSC=Full Load Copper Losses
Constant Losses=Wo (W)
Output=(1/4) X VA X cosФ (cosФ may be assumed)
Input=Output + Copper Loss + Constant Loss
Efficiency (%η) = (Output/Input) X 100
Efficiency at different loads and power factor can be calculated.
Model Graph:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 18
Calculations:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 19
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 20
Result:
Viva Voce Questions:
1. Define transformer.
2. Distinguish the statically induced EMF and dynamically induced EMF.
3. Which losses can be determined from the O.C Test and S.C Test.
4. What is the main AIM’s to conduct the O.C and S.C tests?
5. Define efficiency and voltage regulation of the transformer.
6. Why the O.C Test is conduct on L.V side.
7. Why the S.C Test is conducted on H.V side.
8. What is the difference between U.P.F and L.P.F wattcmeters?
9. No load power factor angle of transformer is around………
10. For which type of load negative voltage regulation occurs.
11. For which type of load maximum voltage regulation occurs.
Exp. No.: Date:
NO-LOAD & BLOCKED ROTOR TESTS ON 3-Ø INDUCTION MOTOR
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 21
Aim:
To draw the equivalent circuit of a 3- Ø Induction Motor and construct the circle diagram
by conducting No-Load & Blocked Rotor Tests.
Apparatus:
S. No. Name of the Equipment Range Type Quantity
1 3- Ø Variac 415V/(0-470)V - 1
2 Ammeter (0-10)A MI 1
(0-5)A MC 1
3 Voltmeter (0-600)V MI 1
(0-150)V MI 1
4 Wattmeter 600V/10A LPF 2
300V/10A UPF 2
5 Connecting Wires - - Required Some
Circuit Diagram:
No-Load Test:
415V/(0-470V)
Blocked Rotor Test:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 22
415V/(0-470V)
Name plate details:
Precautions:
1. 3-Ø Variac should be in minimum position.
Procedure:
No-Load Test:
1. Connect the circuit as shown in circuit diagram.
2. Observing the precautions close the TPST Switch and switch ON 440V A.C Supply.
3. Apply the rated voltage to the stator windings of 3- Ø Induction Motor with the help of 3-
Ø Auto-Transformer.
4. Note down the no-load readings of wattmeter, ammeter and voltmeter.
5. Bring back the auto-transformer to its minimum position and switch OFF the supply.
Blocked Rotor Test:
1. Connect the circuit as shown in circuit diagram.
2. Observing the precautions close the TPST Switch and switch ON 440V A.C Supply.
3. By varying the variac, apply small voltage until the full load current flows in the stator
windings with the rotor unmoved.
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 23
4. Note down the readings and switch OFF the supply after bringing back the auto-
transformer output to minimum position.
Tabular Column:
No-Load Test:
Io (A) V (V) W1 (W) W2 (W)
Blocked Rotor Test:
Current, ISC (A) Voltage, VSC (V) W1 (W) W2 (W)
Stator Resistance per phase =
Formulae:
For Circle Diagram:
cos Øo = Wo
√3 Vo Io
cos ØSC = WSC
√3 VSC ISC
ISN = ISC [Vo / Vsc]
WSN=
Model Graph:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 24
Result:
Viva Voce Questions:
1. What is the importance of circle diagram?
2. Define Faraday’s laws of electromagnetic induction.
3. What are the Tests to be conducted to plot the circle diagram?
4. Which type of wattcmeters is used to conduct blocked rotor test and no load test.
5. What is the AIM’S to conduct the blocked rotor test and no load test?
6. Condition for maximum torque in I.M.
7. What is the reason for high No load current in I.M compare to the Transformer?
8. Formula for calculation of I.M torque at starting and running.
9. What is value of slip at blocked rotor test?
10. What is value of slip at No load test?
Exp. No.: Date:
SCOTT CONNECTION OF TRANSFORMERS
Aim: To convert the given 3- Ø supply into 2- Ø supply using scott connection.
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 25
Apparatus:
S. No. Name of the Equipment Range Type Quantity
1 Voltmeter (0-600)V MI 2
(0-300)V MI 2
2 3- Ø Variac 415V/(0-470)V - 1
3 Ammeter (0-10)A MI 3
4 Resistive Load 1-Ø, 5kW Wire Wound 2
5 Wattmeters 600V/10A UPF 2
6 Connecting Wires - - Required Some
Circuit Diagram:
415V/(0-470V)
Precautions:
1. 3-Ø Variac should be in minimum position.
2. Load must be in OFF position.
Procedure:
1. Connect the circuit as shown in figure 1.
2. Observing the precautions close the TPST Switch and switch ON 440V A.C supply.
3. Apply the rated voltage to the primary of the main teaser transformer with the help of 3-
Φ Auto-transformer.
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 26
4. Note down the readings of all meters for different load settings till rated full load current
of the transformer.
5. Connect the secondaries of the two transformers as shown in figure 2 to verify the phase
relationship of the two phase voltages.
6. Calculate the efficiency of conversion.
7. Observing the precautions switch OFF 440V A.C supply.
Formulae:
Output = V2I2 + V3I3 (W)
Input = W1 + W2 (W)
Efficiency, % η = Output X100
Input
Tabular Columns:
For Figure 1:
W1
(W)
W2
(W)
I1
(A)
I2
(A)
I3
(A)
V1
(V)
V2
(V)
V3
(V)
output
(W)
Input
(W)
η
(%)
Model Graph:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 27
CALCULATIONS:
Result:
Viva Voce Questions:
1. What is the purpose of scoot connection?
2. How many transformers are required for scott connection?
3. What is the KVA rating of the transformer?
4. What are the requirements of Scott connection?
5. What are the applications of the scott connection?
6. What is rated voltage of the transformer used in Scott connection?
7. Name the transformers used in Scoot connection.
8. What is angle between the 2-phase output voltages of the scoot connection?
9. What is the utilization factor for the Scott connection?
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 28
10. What is the utilization factor for open delta transformer connection?
Exp. No.: Date:
EQUIVALENT CIRCUIT OF A 1- Ø INDUCTION MOTOR
Aim: To determine the equivalent circuit parameters of a 1- Ø induction motor by conducting
No-Load, Blocked Rotor and Stator Resistance Measurement Tests.
Apparatus:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 29
S. No. Name of the Equipment Range Type Quantity
1 1- Ø Variac 230V/(0-270)V, 20A - 1
2 Voltmeter (0-300)V MI 1
(0-150)V MI 1
3 Ammeter (0-10)A MI 1
(0-20)A MI 1
4 Wattmeter 300V/10A LPF 1
75V/20A UPF 1
5 Connecting Wires - - Required Some
Circuit Diagram:
No-load Test:
Blocked Rotor Test:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 30
Name plate details:
Precautions:
1. Initially variac must be at zero position.
2. No Loose connections are allowed.
3. Readings should be taken without any parallax errors.
4. Rheostat should be in maximum resistance position.
Procedure:
For No-Load Test:
1. Connect the circuit as shown in circuit diagram.
2. Observing the precautions close the DPST Switch and switch ON 1- Ø A.C supply.
3. Apply the rated voltage by increasing the variac output gradually (No Load is connected
to the motor).
4. Note down the readings of all the meters.
5. Observing the precautions switch OFF the supply.
For Blocked Rotor Test:
1. Connect the circuit as shown in circuit diagram.
2. For performing the blocked rotor test, block the rotor (i.e., not allowed to rotate) by
applying belt-brake arrangement and increase the voltage slowly till rated current flows
and note down all the meter readings.
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 31
3. Observing the precautions switch OFF the supply.
Tabular Columns:
No-Load Test Blocked Rotor Test
Vo (V) Io (A) Wo (W) VSC (V) ISC (A) WSC (W)
Formulae:
oo
o
oIV
Wcos
oo
o
oI
VX
sin
SC
SC
sI
VZ
eqSSS XRZX 22
221
SRrr
221
SXxx
oo
o
oI
VR
cos
S
S
N
NNslip
2
SC
SC
eqSI
WRR
Result:
Viva Voice Questions:
1. What are methods to start the 1-pahse induction motor?
2. What is meant by double field revolving theory?
3. What are the advantages of 3-pahse induction motor compare to 1-phase induction
motor?
4. How the direction of rotation of 1-phase induction motor reverses?
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 32
5. What is forward slip and backward slip for 1-pahse induction motor?
6. When the slip of induction motor nearer to zero?
7. List out 1-phase induction motors.
8. What are the applications of 1-phase induction motor?
9. Where the auxiliary winding is place in the 1-phase induction motor?
10. Why should a motor be named as universal motor?
Exp. No.: Date:
SUMPNER’S TEST
Aim:
i. To conduct Sumpner’s Test on two identical 1- Ø transformers.
ii. To find out the iron loss, copper loss and the efficiency of each transformer.
Apparatus:
S. No. Name of the Equipment Range Type Quantity
1 1- Ø Variac 230V/(0-270)V, 10A - 1
2 1- Ø Transformer 115V/230V, 2kVA Core 2
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 33
3 Ammeter (0-5)A MI 1
(0-20)A MI 1
4 Voltmeter (0-300)V MI 2
(0-75)V MI 1
5 Wattmeter 300V/5A LPF 1
75V/20A UPF 1
Circuit Diagram:
Precautions:
1. The range of voltmeter should be doubled the induced e.m.f of secondary winding.
Procedure:
1. Connect the circuit as shown in circuit diagram.
2. Connect the primaries of both transformers in parallel..
3. Connect the secondaries in series opposition and connect a switch as shown in the circuit
diagram.
4. Initially keep the SPST in open circuit.
5. Give supply as per the primary rating of transformers.
6. Observe the readings of all the meters, close the SPST Switch when voltage Vab = 0 (see
circuit diagram)if it is not so inter change the terminals of primary or secondary but not
both.
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 34
7. By slowly varying the auto transformer-1 up to the rated voltage and note down the all
the meter readings .Here wattmeter gives the core losses of two transformers.
8. By slowly varying the auto transformer-2 up to the rated current passing through both
primaries and secondary’s and note down the all the meter readings .Here wattmeter
gives the copper losses of two transformers.
9. By varying auto transformers 1 & 2, Observe the same readings as per steps 7 & 8. At
this condition the temperature rise of the transformer can be determined.
Tabular Columns:
O.C Test: S.C Test:
Vo (V) Io (A) Wo = W X M.F (W)
VSC (V) ISC (A) WSC = W X M.F (W)
Efficiencies at different loads and power factor:
Load
cosθ = cosθ =
Cu Loss
(W)
Output
(W)
Input
(W)
Efficiency
(%η)
Cu
Loss
(W)
Output
(W)
Input
(W)
Efficiency
(%η)
To find % regulation:
Lagging Power Factor Leading Power Factor
Power Factor % Regulation Power Factor % Regulation
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 35
Model Calculations:
Let the transformer be the step-down transformer (O.C Test)
Primary is H.V side and secondary is L.V side
Ro=V1/Iw (Ω) where Iw=IocosФo
Xo=V1/Iµ (Ω) where Iw=IocosФo
Ro1=WSC/ISC2 (Ω)
ZO1=VSC/ISC
Xo1=√( ZO12 - Ro1
2)
Ro2=K2 Ro1
Xo2=K2 Xo1
where,
K=V2/V1=Transformation Ratio
Calculations to find efficiency:
For example, at 1/4th full load,
Copper Losses=WSC x (1/4)2 (w)
where, WSC=Full Load Copper Losses
Constant Losses=Wo (W)
Output=(1/4) X VA X cosФ (cosФ may be assumed)
Input=Output + Copper Loss + Constant Loss
Efficiency (%η) = (Output/Input) X 100
Efficiency at different loads and power factor can be calculated.
Model Graph:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 36
Calculations:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 37
Result:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 38
Viva Voce Questions:
1. What are the disadvantages of O.C and S.C Tests?
2. What is the need of sumper’s test?
3. What are the other names for sumpner’s test?
4. What are the requirements for the sumpner’s test?
5. Why it is called as heat run test?
6. At what power factor maximum efficiency occurs in transformer.
7. Why it is called as back to back test?
8. How the voltages are applied at low voltage side and high voltage side during sumpner’s test?
9. Formula for voltage regulation, for which power factor voltage regulation is positive, negative
and zero.
10. At unity power factor voltage regulation of transformer is……..
Exp. No.: Date:
REGULATION OF 3-Φ ALTERNATOR BY SYNCHRONOUS IMPEDANCE METHOD
Aim: To predetermine the regulation of a given 3-ΦAlternator by conducting O.C and S.C tests
by Synchronous Impedance Method (E.M.F Method) .
Apparatus:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 39
S. No. Name of the Equipment Range Type Quantity
1 Rheostats 360Ω/1.2A WW 1
2 Ammeter
(0-10)A MI 1
(0-2)A MC 1
(0-5)A MC 1
3 Voltmeter (0-300)V MI 1
(0-30)V MC 1
4 Tachometer (0-10000)rpm Digital 1
5 Connecting Wires - - Required Some
Circuit Diagram:
Precautions:
1. Field rheostat must be kept in minimum resistance position.
2. Armature rheostat must be kept in maximum resistance position.
3. Initially Rectifier should be in zero voltage position.
Procedure:
O.C Test:
1. Connect the circuit as shown in circuit diagram.
2. With the Rectifier in the zero voltage position, TPST Switch open and the rheostats in
their proper positions, the D.C Supply to the motor is switched ON.
3. The D.C Motor is brought to its rated speed and thus the alternator by properly varying
the armature and/or field rheostat of the motor.
4. Now, the alternator field is excited by applying the D.C voltage through the Rectifier in
steps. At each step the field current and the corresponding generated voltage are noted.
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 40
This procedure is repeated till the voltage generated is much beyond rated voltage of the
alternator.
5. Reduce the alternator field excitation to zero level.
S.C Test:
1. With the rectifier in the minimum voltage position, the TPST Switch is closed.
2. Increase field excitation gradually till the Short Circuit Current of the alternator reaches
the rated current of the alternator.
3. Note down the field current required to circulate the rated short circuit current. Tabulate
the readings taken during the O.C Test and S.C Tests.
Tabular Columns:
O.C Test S.C Test
Field Current
If (A)
Phase Voltage
(V)
If(A) ISC (A)
E.M.F Method
P.F
cosΦ
Ia
(A)
Eo (V) % Regulation
Lagging Leading Lagging Leading
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 41
Formulae:
SC
OC
SI
VZ for the same If and speed
22
aSS RZX [Ra = (1.3 to 1.6) Rdc ]
Generated E.M.F of alternator on No-Load is given by
22 )sin()cos( Saaao XIVRIVE
‘+’ for Lagging Power Factor
‘-‘ for Leading Power Factor
Percentage regulation of alternator for a given power factor is given by
100Re% XV
VEg o (%)
where,
Eo = Generated E.M.F of alternator
(or excitation voltage per phase)
V = Full Load rated terminal voltage per phase.
Model Graph:
Calculations:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 42
Result:
Viva Voce Questions:
1. What is the difference between the synchronous and induction machines?
2. What are the different types of alternators?
3. Define regulation, Tell me on which principle the alternator works.
4. Define armature reaction
5. What are the different methods for finding the voltage regulation of alternators?
6. What are the difference between DC generator and AC generator?
7. Which method is optimistic method and pessimistic method for V.R of alternator?
8. Define synchronous reactance.
9. Draw the regulation curve for alternator.
10. Define distribution factor and pitch factor.
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 43
Exp. No.: Date:
DETERMINATION OF Xd & Xq OF SALIENT POLE SYNCHRONOUS MACHINE
Aim: To determine the value of direct axis reactance (Xd) and quadrature axis reactance (Xq) of
the given synchronous machine by conducting slip test.
Apparatus:
S. No. Name of the Equipment Range Type Quantity
1 3-Φ Variac 415V/(0-470)V - 1
2 Rheostat 360Ω/1.2A WW 1
3 Ammeter (0-5)A MI 1
4 Voltmeter (0-150)V MI 1
5 Tachometer (0-10000)rpm Digital 1
6 Connecting Wires - - Required Some
Circuit Diagram:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 44
Precautions:
1. Connections must be made tight.
2. Field rheostat must be kept in minimum resistance position.
3. Starter must be in OFF position.
Procedure:
1. Connect the circuit as shown in circuit diagram.
2. Start the D.C Motor with the help of starter.
3. Adjust the field rheostat of the D.C Motor so that it runs slightly below the synchronous
speed of synchronous machine.
4. Give A.C Supply to the Alternator with the help of variac so that rated current flows in
the synchronous machine.
5. The speed of D.C motor is adjusted such that the points of the meters oscillate between
maximum and minimum values.
6. Note down the maximum and minimum values of ammeter and voltmeter and tabulate
them.
Tabular Columns:
Vmax
(V)
Vmiin
(V)
Imax
(A)
Imin
(A)
Xd
(Ω)
Xq
(Ω)
Formulae:
Direct Axis Synchronous Reactance = Xd = )(min
max I
V
Quadrature Axis Synchronous Reactance = Xq = )(max
min I
V
Result:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 45
Viva Voce Questions:
1. Define saliency?
2. Why this test is not applicable for cylindrical synchronous machines?
3. What is meant by fictitious reactance of alternator?
4. Define leakage reactance of the alternator?
5. Why the synchronous machines are called double excited machines?
6. What is the maximum possible speed of synchronous machine?
7. What is the difference between XS, Xa, and XL?
8. What are inputs for the synchronous machines?
9. What is reluctance offered by the polar axis when compared to quadrature axis?
10. What type of field winding we can provide on salient pole synchronous machines?
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 46
Exp. No.: Date:
V – CURVES AND -CURVES OF A THREE PHASE SYNCHRONOUS MOTOR
Aim:
Conduct an experiment to draw v-curves and -curves of a three phase synchronous
motor.
Apparatus:
Sl.No. Equipment Type Range Quantity
1. Voltmeter MI (0-300)V 1
2. Ammeter MI (0-10)A 1
3. Three phase variac Variable 415V/(0-470)V 1
4. Wattmeter MI 300V,10A,UPF 2
5. Tachometer DIGITAL (0-10000)rpm 1
6. Ammeter MC (0-2)A 1
7. Connecting Wires - -
Required
Some
Circuit Diagram:
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 47
Precautions:
1. Connections must be made tight
2. Meters should be read without parallax error
3. Constant load must be maintained throughout the experiment.
Procedure:
1. Start the synchronous motor by applying rated voltage using an auto transformer.
2. At a constant mechanical load applied on the motor, vary its field excitation in steps to its
rated value noting down the corresponding meter readings at each step and tabulate them.
3. Repeat step 2 for some other load.
4. Plot graphs between If and Ia (V – curve) and If and P. F ( - curves) for the different
loads applied.
Calculations:
21
213
WW
WWTan
21
211 3
WW
WWTan
Power factor = cos
Tabular form:
For load 1 =
If (A) Ia(A) W1(W) W2(W)
21
213
WW
WWTan
Cos
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 48
Model Graph:
Result:
Viva Voice Questions:
1. What are the difficulties in starting a synchronous motor?
2. What are the commonly employed methods of starting a synchronous motor?
3. What are the applications of synchronous motor?
4. What is synchronous condenser?
5. What do you understand by hunting?
6. Why synchronous motor is not self starting ?
7. Difference between synchronous motor and induction motor?
8. Use of damper winding in synchronous machines
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 49
9. What is need of excitation and synchronization in synchronous motor?
10. Explain principle of operation of Synchronous motor.
Exp. No.: Date:
PARALLEL OPERATION OF 1- Ø TRANSFORMER
Aim: .
Apparatus:
S. No. Name of the Equipment Range Type Quantity
1 Voltmeter (0-150)V MI 1
2 1- Ø Transformer 115V/230V, 2kVA Core 2
3 Ammeter (0-2)A MC 1
4 DPST Switch - Knife 1
5 Wattmeter 300V/2A LPF 1
6 Rheostats 360Ω/1.2A WW 1
100Ω/5A WW 1
7 Tachometer (0-10000)rpm Digital 1
8 Connecting Wires - - Required Some
Circuit diagram:
Precautions:
1. Field rheostat of the motor must be in minimum position.
2. Armature rheostat of the motor must be in maximum position.
Procedure:
1. Connect the circuit as shown in circuit diagram.
2. Before starting the experiment, decide at which frequency you conduct No-Load test and
calculate the speed and corresponding voltage to maintain the V/f ratio constant.
3. Observing the precautions switch ON the supply.
4. Run the prime-mover (D.C Motor) at the required speed and adjust the level of
excitation of alternator so as to develop rated transformer primary voltage and then note
down the wattmeter reading after exciting the transformer.
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 50
5. In a gradual manner, simultaneously adjust the excitation of the alternator and its speed
so as to maintain a constant V/f ratio. 6. Repeat the same procedure for different frequencies.
7. After completing the experiment, observing the precautions switch OFF the supply.
Tabular Columns:
Tabular Column-I:
S.No. Speed
N(rpm)
Frequency
f(Hz)
Voltage
V(V) V/f Wi Wi / f
1
2
3
4
Tabular Column-II:
S.No. Frequency
f(Hz)
Hysteresis Losses,
Wi = Af (W)
Eddy Current Losses,
We = Bf2 (W)
Total Iron Losses,
Wi = Wh + We (W)
1
2
3
4
Formulae:
P = 120f ; N1 = 120f1
N P
K = V = Rated Voltage
f Rated frequency
where, f = rated frequency
f1 = selected frequency
N = rated speed
N1 = speed corresponding to f1
Let, Wh = Af
We = Bf2
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 51
Wi = Wh + We = Af + Bf2
Wi = A + Bf
f
A – oa from graph
B – dy = y
dx x
Model Graph:
Result:
Viva Voce Questions:
1. What are the different types of core losses?
2. Define the eddy current loss?
3. Define the hysteresis loss?
4. How to reduce eddy current loss?
5. How to minimize the hysteresis loss?
6. Why the core loss is called constant loss?
7. If BMAX is constant what is the frequency of eddy current loss and hysteresis loss?
ELECTRICAL MACHINES LAB-II
VEMU INSTITUTE OF TECHNOLOGY Page 52
8. If BMAX is not constant the frequency increases what about the hysteresis loss?
9. What are materials to use to design the core of the transformer?
10. How to reduce the leakage flux in transformer