    What is a magnetic line voltage motor starter? An electromagnetic switch with a running overload protection

    (electric motor control 9thedition page 23)

    How many poles are required on motor starters forthe following motors

    a. 240-volt, single-phase induction motor 2

    b. 440-volt, three-phase induction motor 3

    (electric motor control 9thedition page 28)

  • 8/13/2019 Electrical Equipment Report

    3/16

  • 8/13/2019 Electrical Equipment Report

    4/16

    What causes the AC hum or chatter in ACelectromagnetic devices?

    Because were using AC voltage which has 0 voltage. When it reaches0 there is no pull on the armature causing it to drop due to gravity

    and be pulled back in due to the solenoid principle.(electric motor control 9thedition page 27)

    What is the phase relationship between the flux inthe main pole of a magnet and the flux in the

    shaded portion of the pole? 90 degrees apart

    (electric motor control 9thedition page 27)

  • 8/13/2019 Electrical Equipment Report

    5/16

    In what AC devices is the principle of the shadedpole used?

    Magnetic starters on contactor section Relays

    (electric motor control 9thedition page 40)

    What does the electrician look for to remedy thefollowing conditions:

    B. Chatter or Relay

  • 8/13/2019 Electrical Equipment Report

    6/16

    What type of protective enclosure is most commonlyused and what is its NEMA number?

    NEMA 1 General purpose

    (electric motor control 9thedition page 42)

    What advantage is there in using combinationstarters?

    We have both disconnecting switch and starting protection(electric motor control 9thedition page 40)

  • 8/13/2019 Electrical Equipment Report

    7/16

    What safety feature does the combination starterprovide that individual motor starting assemblies

    do not? Starting protection: fuses and circuit breakers

    (electric motor control 9thedition page 42)

    List the probable causes if the armature does not

    release after the magnetic starter is de-energized Mechanical binding, The air gap in magnet is destroyed, Gummy

    substance on magnet faces, Weak tip pressure, Contact tip welding

    (electric motor control 9thedition page 37)

  • 8/13/2019 Electrical Equipment Report

    8/16

  • 8/13/2019 Electrical Equipment Report

    9/16

    The magnetic starter is held closed electrically magnetically

    (http://en.wikipedia.org/wiki/Magnetic_starter )

    When a motor starter coil is de-energized gravity and spring tension open contacts

    (electric motor control 9thedition page 25)

    An AC magnet may hum excessively due to All of these (improper alignment, foreign matter between contact

    surfaces, loose laminations)

    (electric motor control 9thedition page 37)

    http://en.wikipedia.org/wiki/Magnetic_starterhttp://en.wikipedia.org/wiki/Magnetic_starter
  • 8/13/2019 Electrical Equipment Report

    10/16

    AC magnets are made of laminated iron to reduce heating effect

    (http://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-iron)

    (electric motor control 9thedition page 25)

    The purpose of overload protection on a motor isto protect the

    motor from sustained overcurrents

    (electric motor control 9thedition page 29)

    http://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-ironhttp://www.ask.com/answers/309497461/why-are-ac-magnets-made-of-laminated-iron
  • 8/13/2019 Electrical Equipment Report

    11/16

    The number of magnetic starter poles refers to the number of power, motor, or load contacts

    (electric motor control 9thedition page 40)

    Motors may burn out because of all of the above (overload, high ambient temperatures, poor

    ventilation)

    (electric motor control 9thedition basis on chapter 1 introduction)

  • 8/13/2019 Electrical Equipment Report

    12/16

    The purpose of a shading coil on an ACelectromagnetic pole tip is to

    D. prevent chattering

    (http://answers.yahoo.com/question/index?qid=1006041829495)

    (electric motor control 9thedition page 27)

    The current drawn by a motor is B. an accurate measurement of motor load

    (2010 edition electric motors and drives Technical Manual)

    http://answers.yahoo.com/question/index?qid=1006041829495http://answers.yahoo.com/question/index?qid=1006041829495
  • 8/13/2019 Electrical Equipment Report

    13/16

    Thermal overload relays react to A. high ambient temperatures and excessive heating due to overload

    currents

    (electric motor control 9thedition page 30)

    The thermal relay heating element is selected C. From the motors FLA and manufacturers selection chart

    (electric motor control 9thedition page 31)

  • 8/13/2019 Electrical Equipment Report

    14/16

    When the reset button does not reestablish the controlcircuit after an overload, the probable cause is

    B. the overload trip has not cooled sufficiently

    If an operator pushes a start button on a 3-phaseinduction motor and the motor starts to hum, but

    not run, the probable trouble is A. one fuse is blown and the motor is single phasing

  • 8/13/2019 Electrical Equipment Report

    15/16

    A combination starter provides all of these (disconnecting means, overload protection, short-circuit

    protection)

    (electric motor control 9thedition page 40)

    Vacuum contactors A. are quieter in operation than standard contactors

    (electric motor control 9thedition page 44)

    What does IEC stand for? D. International Electrotechnical Commission

    (electric motor control 9thedition page 44)