Electric Screwdrivers BTL-05, BTL-10, BTL-15 DC 20/30 V Instruction Manual Please Read Instructions Before Operating Note This electric screwdriver is designed for indoor use only. Please do not use it outdoors or in a wet environment to prevent the danger of electrocution Pay attention to the voltage specification. Make sure the switch is in the OFF position when you plug in the power Unless you are a trained maintenance personnel, do not disassemble the device lest it causes dangers or more damages Operating Instructions Make sure the power is switched off to install or replace screwdriver bits; pressing the front-end iron cap will allow the screwdriver bits to be inserted or released It is recommended to suspend the electric screwdriver by a flexible balancer for easy operation and prevent its dropping Adjust the torque dial to the proper position according to the dial/torque table for each model The forward/reverse switch should be set to the forward position when fastening screws. Press the start switch to complete the operation. The automatic control model will shut off the power and stop the rotation of the screwdriver bit as soon as the set torque value is reached Position the forward/reverse switch to reverse to loosen screws Use hands to hold the electric screwdriver during operation. Keep it in a perpendicular position with the screw and apply pressure slightly to prevent slipping Use hands or other means to fix the object operated and operate the electrical power screwdriver safely Do not switch the forward/reverse position when the motor is running to prevent the short-circuit of the start switch To ensure long life, use it under the normal operation frequency (8 working hours per day and fasten 800- 1000 screws per hour) Please do not use this type of electric screwdriver to fasten wooden screws Regular Simple Maintenance Check to see whether all the parts, shell, and power lines are intact all the time to ensure normal operations. Unplug the power plug and turn off the power before doing any maintenance operation to ensure safety. For every 1000 hours operation or half year, the following cleaning and maintenance operations to the machine body and the inside are required. ON/OFF Switch 5P Connector Trigger Torque Adjusting Nut Forward/Reverse Switch Torque Dial Bits Holder Collar ON/OFF Switch ON/OFF Switch is on the head of the electric screwdriver ASG, Division of Jergens, Inc. 15700 S. Waterloo Road | Cleveland, OH 44110-3898 Phone: (888) 486-6163 | Fax: (216) 481-4519 Email: [email protected] | Web: www.asg-jergens.com

Transcript of Electric Screwdrivers - ASG, Division of Jergens, Inc.products.asg-jergens.com/Asset/ASG Electric...

Page 1: Electric Screwdrivers - ASG, Division of Jergens, Inc.products.asg-jergens.com/Asset/ASG Electric Screwdrivers...Electric Screwdrivers BTL-05, BTL-10, BTL-15 DC 20/30 V Instruction

Electric Screwdrivers BTL-05, BTL-10, BTL-15

DC 20/30 V

Instruction Manual

Please Read Instructions Before Operating

Note

• Thiselectricscrewdriverisdesignedforindooruseonly.Pleasedonotuseitoutdoorsorinawetenvironmenttopreventthedangerofelectrocution

• Payattentiontothevoltagespecification.MakesuretheswitchisintheOFFpositionwhenyoupluginthepower

• Unlessyouareatrainedmaintenancepersonnel,donotdisassemblethedevicelestitcausesdangersormoredamages

Operating Instructions

• Makesurethepowerisswitchedofftoinstallorreplacescrewdriverbits;pressingthefront-endironcapwillallowthescrewdriverbitstobeinsertedorreleased

• Itisrecommendedtosuspendtheelectricscrewdriverbyaflexiblebalancerforeasyoperationandpreventitsdropping

• Adjustthetorquedialtotheproperpositionaccordingtothedial/torquetableforeachmodel

• Theforward/reverseswitchshouldbesettotheforwardpositionwhenfasteningscrews.Pressthestartswitchtocompletetheoperation.Theautomaticcontrolmodelwillshutoffthepowerandstoptherotationofthescrewdriverbitassoonasthesettorquevalueisreached

• Positiontheforward/reverseswitchtoreversetoloosenscrews

• Usehandstoholdtheelectricscrewdriverduringoperation.Keepitinaperpendicularpositionwiththescrewandapplypressureslightlytopreventslipping

• Usehandsorothermeanstofixtheobjectoperatedandoperatetheelectricalpowerscrewdriversafely

• Donotswitchtheforward/reversepositionwhenthemotorisrunningtopreventtheshort-circuitofthestartswitch

• Toensurelonglife,useitunderthenormaloperationfrequency(8workinghoursperdayandfasten800-1000screwsperhour)

• Pleasedonotusethistypeofelectricscrewdrivertofastenwoodenscrews

Regular Simple Maintenance

Checktoseewhetheralltheparts,shell,andpowerlinesareintactallthetimetoensurenormaloperations.Unplugthepowerplugandturnoffthepowerbeforedoinganymaintenanceoperationtoensuresafety.Forevery1000hoursoperationorhalfyear,thefollowingcleaningandmaintenanceoperationstothemachinebodyandtheinsidearerequired.

ON/OFF Switch5P Connector

Trigger

Torque Adjusting Nut

Forward/Reverse Switch

Torque Dial

Bits Holder Collar

ON/OFF SwitchON/OFFSwitchisontheheadoftheelectricscrewdriver

ASG, Division of Jergens, Inc.

15700S.WaterlooRoad|Cleveland,OH44110-3898Phone:(888)486-6163|Fax:(216)481-4519Email:[email protected]|Web:www.asg-jergens.com

Page 2: Electric Screwdrivers - ASG, Division of Jergens, Inc.products.asg-jergens.com/Asset/ASG Electric Screwdrivers...Electric Screwdrivers BTL-05, BTL-10, BTL-15 DC 20/30 V Instruction

Output Torque/Adjust Dial Soft Start Adjustable Time Setting Switch Power Supply

Usercanadjustoutputtorquerangeofthetoolviachangingthetorquespring.Pleaserefertothetorque/dialtableandthenturnthe“torqueadjustingnut”tosettheproperdialforeachmodelofmachineandsettothedesiredtorqueforoperations.

TheBTL-05,BTL-10andBTL-15brushlesselectricscrewdriverspossessSoftStartadjustabletimesettingswitch.Usercansetthemachinestostartfromlowerspeedfor0.2-4.0secondsandthenswitchtofullspeedoperatingautomatically.

Withfivelevelstochoose:0.0sec/0.5sec/1sec/2sec/4sec

Switching Power SupplyBTL-5A (65710)

Theadjustableswitchisatthecorrespondingpositioninsidethesquareopening.Seetheredcircleontherightpicture.

TurntheswitchseparatelytosetthetimeofSoftStart

Carefullytakeoffthetagfromitsside,andusercanseeasmallsquareopeningasthepictureshows.

Adjusting Torque

• Thedialsontheelectricscrewdriverdonotrepresentthetorquevalue

• Pleaseusethetorque/dialtabletosettheproperdialforeachdifferentmachinetypeandsettothedesiredtorqueforoperations

• Actualtorqueoutputshouldalwaysbeverifiedwithatorquetester,suchastheASGDTTseries

• TheBTL-05,BTL-10andBTL-15brushlesselectricscrewdriverscanbeusedwithswitchingpowersupplyBTL-5A(65710)

• Theelectricscrewdriverconnectstothepowersupplywith5Pconnectingwire

• Insurethatthepowersupplyisconnectedat90-240V50/60Hz,andturnonthepower

• ByturningtheHI/LOWswitch,usercanadjustthespeedoftheelectricscrewdriver

• WhenusingthePS-55powersupply,thescrewcounterSTC-02andSoftStartfeaturewillnotfunction

Torque Adjusting Nut

BTL-05