Electric Actuated Flow Control Valve

13
SINCE 1989 Electric Actuated Flow Control Valves LIAONING SJD TRADING CO. LTD.

Transcript of Electric Actuated Flow Control Valve

SINCE 1989Electric Actuated Flow Control ValvesLIAONING SJD TRADING CO. LTD.

Annual Exported Sales Revenue

6/30/2016 [email protected]

Main Products

3730 Electro-Hydraulic Actuator

3610 Rotary Stroke Explosion Proof Actuator

3720 Non-invasive Electric Actuator

6/30/2016 [email protected]

3730 Electro-Hydraulic Actuator

Rotary Stem Motion Type

Max. Output: 120000Nm

Power Source: 380VAC

Max Angle: 90°

Eviroment Temp.: -10℃~+60℃

Deadband: 0.6%

Positioning accuracy: <1.0%

Repeatability: <1.0%

Enclosure type: ExdllBT4 IP65

6/30/2016 [email protected]

3730 Electro-Hydraulic Actuator

Swing cylinder drive, compact structure, stronger output torque

Automatically action memory function, cumulating time and numbers for control and maintenance.

Non-invasive remote control operation, manually setting parameter without opening enclosure

6/30/2016 [email protected]

3610 Explosion Proof Actuator

6/30/2016 [email protected]

Stem Motion Type: Linear and Rotary

Max. Output: 16000Nm & 2500Nm

Power Source: 220VAC

Control Signal: 4-20mADC/1-5VDC

Deadband: 0.8%

Positioning accuracy: ≤1.0%

Response Time: ≤0.8S

Environment Rating: IP55

3730 Electro-Hydraulic Actuator

Widely used automation and control

6/30/2016 [email protected]

Reliability, easy operation and maintenance

Enclosure type: ExdllBT4

3720 Non-invasive Electric Actuator

6/30/2016 [email protected]

Stem Motion Type: Linear and Rotary

Max. Output: 10000Nm & 600Nm

Power Source: 220VAC

Control Signal: 4-20mADC

Deadband: 0.8%

Positioning accuracy: ≤1.0%

Response Time: ≤0.8S

Environment Rating: IP65

3720 Non-invasive Electric Actuator

Advanced hybrid integrated circuits

Output point feedback, self-diagnostic and alarm functions

Non-invasive remote control operation, manually setting parameter without opening enclosure

6/30/2016 [email protected]

Order Notice-necessary

6/30/2016 [email protected]

Actuator type (If unclear, provide: action mode, output power

or way of control)

Supply Voltage

Stroke

Installation place and temperature (Temperature is lower

than -10℃, “heating element” shall be noted; when lower

than -30℃, relative insulation protection shall be added

according to the circumstance.)

Order Notice-support

6/30/2016 [email protected]

Related Valve Type

Pipe Installation Direction

Contact Information

Contact: Susan Yao LIAONING SJD TRADING CO., LTD.Email: [email protected]://www.valve4s.com/en/https://plus.google.com/u/0/105474428703289057133https://www.facebook.com/valvepipefittinghttps://www.linkedin.com/company/liaoning-sjd-trading-co--ltd-https://www.pinterest.com/oilandgasvalve/

6/30/2016 [email protected]

THANKS

6/30/2016 [email protected]