S1 Supporting Information Efficient photocatalytic hydrogen generation from water by a cationic cobalt(II) porphyrin Mirco Natali, a* Alessandra Luisa, b Elisabetta Iengo, b* and Franco Scandola a* (a) Dipartimento di Scienze Chimiche e Farmaceutiche, Università degli Studi di Ferrara, via Fossato di Mortara 17-19, 44121 Ferrara, Italy, and Centro Interuniversitario per la Conversione Chimica dell'Energia Solare, sezione di Ferrara, via L. Borsari 46, 44121 Ferrara, Italy. E-mail: [email protected], [email protected]. (b) Dipartimento di Scienze Chimiche e Farmaceutiche, Università degli Studi di Trieste, via L. Giorgieri 1, 34127 Trieste, Italy. E-mail: [email protected] Electronic Supplementary Material (ESI) for Chemical Communications This journal is © The Royal Society of Chemistry 2014

Transcript of Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase...

Page 1: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S1

Supporting Information

Efficient photocatalytic hydrogen generation from

water by a cationic cobalt(II) porphyrin

Mirco Natali,a* Alessandra Luisa,b Elisabetta Iengo,b* and Franco Scandola a*

(a) Dipartimento di Scienze Chimiche e Farmaceutiche, Università degli Studi di Ferrara, via

Fossato di Mortara 17-19, 44121 Ferrara, Italy, and Centro Interuniversitario per la Conversione

Chimica dell'Energia Solare, sezione di Ferrara, via L. Borsari 46, 44121 Ferrara, Italy.

E-mail: [email protected], [email protected].

(b) Dipartimento di Scienze Chimiche e Farmaceutiche, Università degli Studi di Trieste, via L.

Giorgieri 1, 34127 Trieste, Italy.

E-mail: [email protected]

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 2: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S2

Materials and Methods

Materials. Acetonitrile for electrochemical studies was of spectroscopic grade, while for

photophysical and photolysis experiments Milli-Q Ultrapure water and related buffer were used, all

the other reagents were of reagent grade quality, and used as received. Ru(bpy)3Cl2∙6H2O, ascorbic

acid and 5,10,15,20-tetrakis (4'-pyridyl) porphyrin (TPyP) were purchased from Sigma Aldrich.

Insertion of cobalt(II) inside the TPyP porphyrin core, and methylation of the four peripheral

pyridyl groups of Zn(II)TPyP and Co(II)TPyP, were performed following slightly adapted literature

procedures, see below.S1,S2

NMR. 1H spectra were recorded on a Varian 500 (500 MHz) or on a JEOL Eclipse 400FT (400

MHz) spectrometer. All spectra were run at room temperature; 1H chemical shifts were referenced

to the peak of residual non-deuterated solvent (δ = 7.26 ppm for CDCl3, 2.50 ppm for DMSO-d6) or

to TMS (δ = 0 ppm) for D2O.

Mass Spectrometry. Electrospray Ionization (ESI) measurements were performed on a Perkin

Elmer APII at 5600 eV by Dr. Fabio Hollan, Department of Chemical and Pharmaceutical Sciences,

University of Trieste, Italy.

Electrochemical Meaurements. Cyclic Voltammetry (CV) measurements were carried out with

a PC-interfaced Eco Chemie Autolab/Pgstat 30 Potentiostat. Argon-purged 10-4 M sample solutions

in acetonitrile, containing 0.1 M LiClO4, or in 1 M phosphate buffer at pH 7 were used. A

conventional three-electrode cell assembly was adopted: a saturated calomel electrode (SCE Amel)

and a platinum electrode, both separated from the test solution by a frit, were used as reference and

counter electrodes, respectively; a glassy carbon electrode was used as the working electrode.

Steady-state Absorption/Emission Measurements. UV-Vis absorption spectra were recorded

on a Jasco V-570 UV/Vis/NIR or on a V-550 UV/Vis spectrophotometer. Emission spectra were

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 3: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S3

taken on a Horiba-Jobin Yvon Fluoromax-2 spectrofluorimeter, equipped with a Hamamatsu R3896

tube.

Nanosecond Laser Flash Photolysis. Nanosecond transient measurements were performed with

a custom laser spectrometer comprised of a Continuum Surelite II Nd:YAG laser (FWHM 6-8 ns)

with frequency doubled, (532 nm, 330 mJ) or tripled, (355 nm, 160 mJ) option, an Applied

Photophysics xenon light source including a mod. 720 150 W lamp housing, a mod. 620 power

controlled lamp supply and a mod. 03-102 arc lamp pulser. Laser excitation was provided at 90°

with respect to the white light probe beam. Light transmitted by the sample was focused onto the

entrance slit of a 300 mm focal length Acton SpectraPro 2300i triple grating, flat field, double exit

monochromator equipped with a photomultiplier detector (Hamamatsu R3896) and a Princeton

Instruments PIMAX II gated intensified CCD camera, using a RB Gen II intensifier, a ST133

controller and a PTG pulser. Signals from the photomultiplier (kinetic traces) were processed by

means of a LeCroy 9360 (600 MHz, 5 Gs/s) digital oscilloscope.

Photolysis Apparatus. The hydrogen evolution experiments were carried out upon continuous

visible light irradiation with a 175 W xenon CERMAX arc-lamp (cut-off filter at 400 nm) of a

reactor (a 10 mm pathlength pyrex glass cuvette with head space obtained from a round-bottom

flask) containing the solution. The measuring cell is sealed during the photoreaction: the head to

which cell is attached has indeed four ports, closed with Swagelok® connections, two of them are

part of a closed loop involving GC gas inlet and sample vent in order to analyze head space content

without an appreciable gas consumption, and the other two are for the degassing procedure (input

and output).

Gas Chromatography. The gas phase of the reaction vessel was analyzed on an Agilent

Technologies 490 microGC equipped with a 5 Å molecular sieve column (10 m), a thermal

conductivity detector, and using Ar as carrier gas. 5 mL from the headspace of the reactor are

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 4: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S4

sampled by the internal GC pump and 200 nL are injected in the column maintained at 60°C for

separation and detection of gases. The unused gas sample is then reintroduced in the reactor in order

to minimize its consumption along the whole photolysis. The amount of hydrogen was quantified

through the external calibration method. This procedure was performed, prior to analysis, through a

galvanostatic (typically 1 mA) electrolysis of a 0.1 M H2SO4 solution in an analogous cell (same

volume) equipped with two Pt wires sealed in the glass at the bottom of the cell. A 100% faradaic

efficiency was assumed leading to a linear correlation between the amount of H2 evolved at the

cathode and the electrolysis time.

Hydrogen Evolution Experiments. In a typical experiment, samples of 5 mL were prepared in

20 mL scintillation vials by mixing appropriate aliquots of 1 M phosphate buffer, of a 5 mM

Ru(bpy)3Cl2∙6H2O solution in 1 M phosphate buffer, of a 0.1 mM CoP mother solution in 1 M

phosphate buffer and further adding AscH (as solid). The solution was then put in the reactor,

degassed by bubbling Ar for 30 min, and thermostated at 15°C. The cell was then irradiated under

continuous vigorous stirring of the solution. The gas phase of the reaction was analyzed through GC

and the amount of hydrogen quantified.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 5: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S5

Synthesis and characterization

Chart S1.

5,10,15,20-tetrakis (4'-pyridyl) zinc(II) porphyrin – Zn(II)TPyP. TPyP (49.5 mg, 0.080

mmol) is dissolved in chloroform (30 mL) and stirred for 16 hours with an excess of

Zn(CH3COO)2·2H2O (43.9 mg, 0.20 mmol), dissolved in a minimum amount of methanol. The

violet product is precipitated by adding methanol to the concentrated reaction mixture, filtered,

washed thoroughly with methanol and dried under vacuum. Yield: 51.9 mg (95.1%). UV-Vis.

(DCM, λ, nm) 427 (Soret), 560, 599 (Q bands). 1H-NMR (500 MHz, CDCl3 + 40 μL pyridine-d5,

δ, ppm) 8.94 (d, J = 5.8 Hz, 8H, pyaH), 8.83 (s, 8H, βH), 8.07 (d, J = 5.8 Hz, 8H, pybH).

5,10,15,20-tetrakis (4'-pyridyl) cobalt(II) porphyrin – Co(II)TPyP. TPyP (53.7 mg, 0.087

mmol) is dissolved in chloroform (30 mL) and stirred for 16 hours with an excess of

Co(CH3COO)2·4H2O (54.0 mg, 0.22 mmol) dissolved in a minimum amount of methanol. The

reaction is quenched by addition of deionized water (30 mL). A purple product precipitates after

cooling the mixture. The precipitated is filtered, washed thoroughly with methanol and dried under

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 6: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S6

vacuum. Yield: 44.8 mg (76.3%). UV-Vis. (DCM, λ, nm) 425 (Soret), 544 (Q band). ESI-MS m/z

calcd. for C40H24N8Co ([M]+) 675.1, found 675.2.

5,10,15,20-tetrakis (1-methylpyridinium-4'-yl) zinc(II) porphyrin – [Zn(II)NMeTPyP4+][I-]4.

Zn(II)TPyP (27.3 mg, 0.040 mmol) is treated in DMF (5 mL) with a large excess of methyl iodide

(0.125 mL, 2 mmol) for 2 hours at refluxing temperature. After addition of diethyl ether, a violet

solid precipitates and the unreacted CH3I stays in the diethyl ether phase. The product is filtered,

washed with cold diethyl ether, recrystallized with a water/ethanol mixture and dried under vacuum.

Yield: 33.8 mg (84.7%). UV-Vis. (H2O, λ, nm) 436 (Soret), 564, 605 (Q bands).1H-NMR (500

MHz, D2O, δ, ppm) 9.33 (d, J = 6.1, 8H, pyaH), 9.16 (s, 8H, βH), 9.01 (d, J = 6.1, 8H, pybH), 4.85

(s, 12H, CH3). 1H NMR (400 MHz, DMSO-d6, δ, ppm) 9.43 (d, J = 4.3 Hz, 8H, pyaH), 9.09 (s, 8H,

βH), 8.92 (d, J = 4.8 Hz, 8H, pybH), 4.72 (s, 12H, CH3).

5,10,15,20-tetrakis (1-methylpyridinium-4'-yl) cobalt(II) porphyrin – [Co(II)NMeTPyP4+][I-]4

– CoP. Co(II)TPyP (30.4 mg, 0.045 mmol) is treated in DMF (5 mL) with a large excess of methyl

iodide (0.140 mL, 2.25 mmol) for 2 hours at refluxing temperature. After addition of diethyl ether, a

purple solid precipitates and the unreacted CH3I stays in the diethyl ether phase. The product is

filtered, washed with cold diethyl ether, recrystallized with a water/ethanol mixture and dried under

vacuum. Yield: 27.6 mg (83.4%). ESI-MS m/z calcd. for C44H36N8Co4+ ([M-4I]+) 183.8, found

183.7. UV-Vis (Figure S3). (H2O, λ, nm) 433 (Soret), 544 (Q band).

Chloro(4-Ethyl-pyridine)bis(dimethylglyoximate) cobalt(III). Co(dmgH)2Cl(EtPy) was

synthesized according to literature procedure.S3

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 7: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S7

Calculation of the electron transfer rate constant

The rate of the electron transfer reaction

Ru(I) + CoP → Ru(II) + CoP− (1)

can be described as follows:

v = k [Ru(I)][CoP] = kobs [Ru(I)] (2)

(under pseudo-first order kinetic conditions : [CoP] >> [Ru(I)])

where k is the «bimolecular rate constant» and:

kobs = k [CoP] (3)

The evolution of [Ru(I)] in time can be monitored by laser flash photolysis:

[Ru(I)] = [Ru(I)]0 exp (−kobs t) (4)

and obtaining the kobs value from an exponential fitting of the kinetic traces. By plotting kobs vs.

[CoP] and according to eq 3, the slope is k, i.e., the «bimolecular rate constant».

However, it must be considered that recombination of the reduced sensitizer with oxidized AscH is

in competition with electron transfer to CoP (eq 1), therefore electron transfer rates from Ru(I) to

CoP are calculated as follows:

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 8: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S8

0 20 40 60 80 100 120 140 160 180

0.00

0.02

0.04

0.06

0.08

∆OD

(510

nm

)

time, µs

0 M 25 µM 50 µM

- no CoP (black trace): τ0 = 37 µs

- 25 µM CoP (blue trace):

τ1 = 11 µs (80%), τ2 = 115 µs (20%) with kobs = 1/τ1 - 1/τ0

- 50 µM CoP (green trace):

τa = 7 µs (80%), τb = 90 µs (20%) with kobs = 1/τa - 1/τ0

The kinetic traces of 25-50 µM CoP solutions are always fitted with bi-exponential functions, the

longer component (accounting for the 20% in both cases) is ascribed to the decay of the reduced

CoP and is therefore not considered in the calculation.

0 10 20 30 40 50

0.0

2.0x104

4.0x104

6.0x104

8.0x104

1.0x105

1.2x105

k obs,

s-1

[CoNMeTPyP], µM

Slope 2.2724E9

k = 2.3 × 109 M-1s-1

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 9: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S9

References

[S1] M. Perrée-Fauvet, C. Verchère-Béaur, E. Tarnaud, G. Anneheim- Herbelin, N. Bône and A.

Gaudemer, Tetrahedron, 1996, 52, 13569.

[S2] B. Steiger, C. Shi and F. C. Anson, Inorg. Chem., 1993, 32, 2017.

[S3] G. N. Schrauzer, Inorg. Synth., 1968, 11, 61.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 10: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S10

Figure S1. Top: ESI-MS spectrum of Co(II)TPyP; m/z calcd. for C40H24N8Co ([M]+) 675.1, found

675.2. Bottom, left: isotopic distribution calculated of the [M]+ molecular peak (program IsoPro3);

bottom, right: experimental isotopic distribution calculated of the [M]+ molecular peak.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 11: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S11

Figure S2. ESI-MS spectrum of CoP; m/z calcd. for C44H36N8Co4+ ([M-4I]4+) 183.8, found 183.7.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 12: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S12

300 400 500 600 700 8000

10

20

30

40

50

60ε,

x 10

3 M-1cm

-1

wavelength, nm

Figure S3. Electronic absorption spectrum of CoP in water.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 13: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S13

0.0 -0.2 -0.4 -0.6 -0.8 -1.0 -1.2 -1.4 -1.6 -1.8

1

2

3

4

5

6

7

8 CoP blank

∆I (µ

A)

E (V) vs SCE

(a)

(b)

-0.4 -0.6 -0.8 -1.0 -1.2 -1.4 -1.6 -1.8 -2.0

-2

0

2

4

6

8

10

12

14

i (µA

)

E (V) vs SCE

Figure S4. (a) Cyclic voltammetry (CV) of 0.1 mM CoP solution in acetonitrile (0.1 M LiClO4,

scan rate 100 mV/s, room temperature). (b) Differential pulsed voltammetry (DPV) of 0.1 mM CoP

solution in acetonitrile (0.1 M LiClO4, ∆E = 20 mV, room temperature), compared with blank.

Reduction of dioxygen (inevitably present as residual traces in our working conditions) show up as

a distinguishable peak, very close to the first CoP reduction, in the DPV measurements. In the CV

measurements, it certainly contributes, together with CoP reduction, to the intensity of the first

unresolved cathodic process.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 14: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S14

-0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1.0 -1.1 -1.2-2

0

2

4

6

8

10i (

µA)

E (V) vs SCE

Figure S5. Cyclic voltammetry of 0.1 mM Zn(II)NMeTPyP4+ solution in acetonitrile (0.1 M

LiClO4, scan rate 100 mV/s, room temperature).

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 15: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S15

-0.4 -0.6 -0.8 -1.0 -1.2 -1.4 -1.6 -1.8 -2.0-202468

1012141618 0 M

0.3 mM 0.5 mM 0.7 mM 1.0 mM 1.3 mM

i (µA

)

E (V) vs SCE

Figure S6. Cyclic voltammetry of 0.1 mM CoP solution in acetonitrile (0.1 M LiClO4, scan rate

100 mV/s, room temperature) upon addition of different amount of benzoic acid (0-1.3 mM).

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 16: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S16

0 5 10 15 20 25 30

0.0

0.1

0.2

0.3

0.4

0.5

0.6

Initia

l Rat

e, µ

mol

min

-1

[CoP], µM

(a)

(b)

Figure S7. Plots of initial rate of hydrogen production (calculated in the linear part of the kinetic

after the induction period) vs CoP concentration: (a) 0-7.5 µM and (b) 0-30 µM.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 17: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S17

400 500 600 700 8000.0

0.5

1.0

1.5

2.0

2.5

3.0Ab

s

wavelength, nm

before after

400 500 600 700 8000.0

0.5

1.0

1.5

2.0

2.5

3.0

Abs

wavelength, nm

before after

400 500 600 700 8000.0

0.5

1.0

1.5

2.0

2.5

3.0

Abs

wavelength, nm

before after

400 500 600 700 8000.0

0.5

1.0

1.5

2.0

2.5

3.0

Abs

wavelength, nm

before after

400 500 600 700 8000.0

0.5

1.0

1.5

2.0

2.5

3.0

Abs

wavelength, nm

before after

400 500 600 700 8000.0

0.5

1.0

1.5

2.0

2.5

3.0

Abs

wavelength, nm

before after

(a) (b)

(d) (c)

(f) (e)

Figure S8. Comparison of absorption spectra before/after photolysis of solution containing 1 mM

Ru(bpy)32+, 0.1 M AscH and (a) 2.5 µM (4 h), (b) 5.0 µM (4 h), (c) 7.5 µM (4 h), (d) 10 µM (4 h),

(e) 20 µM (4 h 30 min), and (f) 30 µM (5 h) CoP in 1 M phosphate buffer at pH 7.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 18: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S18

0 40 80 120 160 200 240

0

2

4

6

8

10

12

14

16TO

N

CoP Co(dmgH)2ClEtPyn

H 2, µm

ol

time, min

0

80

160

240

320

400

480

560

640

Figure S9. Kinetic of hydrogen evolution upon irradiation of solutions containing 1 mM

Ru(bpy)32+, 0.1 M AscH, and 5 µM CoP (black trace) or 5 µM cobaloxime (red trace) in 1 M

phosphate buffer at pH 7.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 19: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S19

0 60 120 180 240 300 360 420

0

2

4

6

8

10

100 µM Co(dmgH)2ClEtPy 2.5 µM CoP

n H 2,

µmol

time, min

Figure S10. Kinetic of hydrogen evolution upon irradiation of solutions containing 1 mM

Ru(bpy)32+, 0.1 M AscH, and 2.5 µM CoP (red trace) or 100 µM cobaloxime (black trace) in 1 M

phosphate buffer at pH 7.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 20: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S20

(a)

(b)

Figure S11. (a) Kinetic of hydrogen evolution upon irradiation of solutions containing 1 mM

Ru(bpy)32+, 0.1 M AscH, and 5.0 µM CoP in 1 M phosphate buffer at different pH; (b) plot of TON

and TOF vs. pH.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 21: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S21

400 500 600 700 8000.0

0.5

1.0

1.5

2.0

2.5

3.0Ab

s

wavelength, nm

before after

400 500 600 700 8000.0

0.5

1.0

1.5

2.0

2.5

3.0

Abs

wavelength, nm

before after

400 500 600 700 8000.0

0.5

1.0

1.5

2.0

2.5

3.0

Abs

wavelength, nm

before after

400 500 600 700 8000.0

0.5

1.0

1.5

2.0

2.5

3.0

Abs

wavelength, nm

before after

(a) (b)

(c) (d)

Figure S12. Comparison of absorption spectra before and after 2 h photolysis of solution containing

1 mM Ru(bpy)32+, 0.1 M AscH, and 5.0 µM CoP in 1 M phosphate buffer at (a) pH 5, (b) pH 6, (c)

pH 7, and (d) pH 8.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 22: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S22

500 550 600 650 700 750 800 850

Inte

nsity

, a.u

.

wavelength, nm

0 M 0.1 M 0.2 M 0.3 M

0.00 0.05 0.10 0.15 0.20 0.25 0.30

1

2

3

4

5

I 0 / I

[AscH], M

Slope 14.1113

(a)

(b)

Figure S13. (a) Photoluminescence spectra (excitation at 450 nm) of solution containing 50 µM

Ru(bpy)32+ in 1 M phosphate buffer at pH 7 after addition of different aliquots of AscH (0-0.3 M);

(b) Stern-Volmer plot of quenching by AscH.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 23: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S23

500 550 600 650 700 750 800 850

Inte

nsity

, a.u

.

wavelength, nm

0 M 10 µM 20 µM 30 µM 40 µM

0 10 20 30 40

1.00

1.02

1.04

1.06

1.08

1.10

1.12

1.14

1.16

I 0 / I

[CoP], µM

Slope 3516.5352

(a)

(b)

Figure S14. (a) Photoluminescence spectra (excitation at 470 nm) of solution containing 50 µM

Ru(bpy)32+ in 1 M phosphate buffer at pH 7 after addition of different aliquots of CoP (0-40 µM);

(b) Stern-Volmer plot of quenching by CoP (inner filter correction applied).

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 24: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S24

0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75-0.18-0.16-0.14-0.12-0.10-0.08-0.06-0.04-0.020.000.02

τ = 170 ns

∆OD

(450

nm

)

time, µs0 25 50 75 100 125 150 175

-0.02

0.00

0.02

0.04

0.06

0.08∆O

D (5

10 n

m)

time, µs

τ = 37 µs

(a) (b)

(c) (d)

Figure S15. Laser flash photolysis of a solution containing 0.1 mM Ru(bpy)32+ and 0.1 M AscH in

1 M phosphate buffer at pH 7: (a) transient absorption spectra between 0.01-0.50 µs time-delay

(reductive quenching by AscH), (b) transient absorption spectra between 1.0-100 µs time-delay

(charge recombination), (c) kinetic analysis at 450 nm, and (d) kinetic analysis at 510 nm.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014

Page 25: Efficient photocatalytic hydrogen generation from water by ... · Gas Chromatography. The gas phase of the reaction vessel was analyzed on an . Agilent Technologies. 490 microGC equipped

S25

400 500 600 700 800

-0.02

-0.01

0.00

0.01

0.02

0.03

∆O

D

wavelength, nm

30 µs 50 µs 100 µs

Figure S16. Zoom of transient spectra of Figure 3a of the main article: transient spectra at 30, 50,

and 100 µs time delay obtained by laser flash photolysis of a solution containing 0.1 mM

Ru(bpy)32+, 0.1 M AscH, and 25 µM CoP in 1 M phosphate buffer at pH 7.

Electronic Supplementary Material (ESI) for Chemical CommunicationsThis journal is © The Royal Society of Chemistry 2014