Edwards Fogarty Catheters...Fogarty® clot management catheters 140806 160245F 140808 160246F...
Transcript of Edwards Fogarty Catheters...Fogarty® clot management catheters 140806 160245F 140808 160246F...
Edwards Fogarty® Catheters
The only name in clot management backed by over 50 years of worldwide experience.
For over 50 years, clinicians have counted on real Fogarty® catheters to address the real problem of clot management.
The reason is simple. Through collaboration and clinical learning, Edwards Lifesciences has continued to evolve and advance its Fogarty catheters to meet the exacting needs of specialists for vascular procedures. Their proven performance and manufacturing quality has led surgeons to specify genuine Fogarty catheters – available exclusively from Edwards – for millions of procedures worldwide.
Fresh, soft emboli/thrombi Fogarty arterial embolectomy catheterSimple, rapid removal of soft, fresh emboli and thrombi from the arterial system• Hand-tied using a recessed winding technique to secure balloon to catheter • Balloon exhibits a symmetry that exerts uniform contact with vessel walls
for even pressure and precise traction • Soft, rounded tip promotes easy insertion for reduced trauma
Fogarty Fortis arterial embolectomy catheterFor more aggressive removal of emboli and thrombi from the arterial system• Construction and materials designed to be more durable and withstand
greater pull-force• The addition of barium to the catheter shaft material provides radiopacity
Fresh, soft emboli/thrombi, temporary occlusion, infusionOver-the-wire Fogarty thru-lumen embolectomy catheter Multi-use, guidewire-compatible design enables removal of soft, fresh emboli and thrombi as well as fluid delivery, temporary occlusion, and blood sampling • Tough, compliant Fogarty balloon conforms to the vessel to maximize
clot removal while minimizing trauma • Provides the solution for distal thrombus removal in the arterial system• The addition of barium to the catheter shaft material and stainless steel
markers proximal and distal to the balloon provide radiopacity
For over 50 years, clinicians have counted on real Fogarty® catheters to address the real problem of clot management.
Mature, adherent thrombi Fogarty Corkscrew catheterUsed to dislodge adherent material in native vessels and synthetic grafts• For extracting thrombus that is too resistant for an
elastomeric balloon • Corkscrew design increases the surface area for entrapping
fibrous material • Radiopaque and flexible
Fogarty graft thrombectomy catheterDesigned for removing organized and adherent thrombus from synthetic grafts, such as aortofemoral grafts• For thrombus that is too resistant for an elastomeric balloon• Provides a larger diameter range than the Fogarty Corkscrew catheter• The pulling force can be varied by adjusting the diameter
Venous thrombi Fogarty venous thrombectomy catheterDesigned for removing thrombi in the venous system• The long, soft tip facilitates advancement past the venous
valves without undue trauma
Fogarty irrigation catheter (not shown)Can be used to heparinize the arterial tree following embolectomy or venous thrombectomy
You’ll want a real
CAUTION: Federal (United States) law restricts this device to sale by or on the order of a physician. See instructions for use for full prescribing information, including indications, contraindications, warnings, precautions and adverse events.
Edwards, Edwards Lifesciences, the stylized E logo, Fogarty, Fogarty Corkscrew, Fogarty Fortis, and 1-800-FOGARTY are trademarks or service marks of Edwards Lifesciences Corporation or its affiliates. All other trademarks are the property of their respective owners.
© 2020 Edwards Lifesciences Corporation. All rights reserved. PP- -US-0590 v2.0
Edwards Lifesciences • One Edwards Way, Irvine CA 92614 USA • edwards.com
Genuine Fogarty catheters are available exclusively from Edwards Lifesciences. To learn more, visit edwards.com/fogarty or call 1-800-FOGARTY.
Fogarty® clot management catheters
140806
160245F
140808
160246F
1408010
80
50
80
50
80
4
5
5
6
6
2.7
5.0
3.1
6.0
3.3
6
16
8
18
10
ModelUsable length(cm)
Catheter Size (F)
Membrane/spiral diameter max. extended (mm)
Membrane/spiral diameter max. retracted (mm)
Fogarty Corkscrew catheters
Fogarty graft thrombectomy catheters
120602F
12A0602F
120404FF
320806F
220804F220806F2202310F
320808F32080810F
12TLW403F
120804FF
12TLW803F12TLW1203F12TLW404F12TLW804F12TLW405F3512TLW805F3512TLW406F12TLW806F12TLW807F
12A0403F12A0803F12A0404F12A0804F12A1004F12A0805F12A0806F12A0807F
120403F120803F120404F120804F120805F120806F120807F
60
60
40
80
808023
8080
40
80
8012040804080408080
40804080100808080
40804080808080
2
2
4
6
4610
88
3
4
33445.55.5667
33444567
3344567
4
4
9
12
–––
1319
5
9
55991111131314
55999111314
5599111314
3.4
3.4
5.0
7.7
–––
8.810.0
4.5
5.0
4.54.55.05.06.06.07.07.08.0
4.34.35.05.05.06.07.08.0
4.34.35.05.06.07.08.0
0.2
0.2
1.7
3.0
–––
4.58.0
0.4
1.7
0.40.41.21.21.71.72.32.32.8
0.60.61.71.71.73.04.55.0
0.60.61.71.73.04.55.0
–
–
0.75
1.50
–––
2.254.00
0.15
0.75
0.150.150.500.500.900.901.401.401.60
2.02.00.750.750.751.502.002.50
0.200.200.750.751.502.002.50
0.5
0.5
–
–
–––
––
0.7
–
0.70.71.51.52.02.02.52.53.5
0.70.71.51.51.52.02.53.5
0.70.71.51.52.02.53.5
3.5
3.5
5
–
–––
––
4.5
5
4.54.55566778
44555678
4455678
–
–
–
–
–––
––
0.018
–
0.0180.0180.0250.0250.0350.0350.0350.0350.038
––––––––
–––––––
Model
Usable length (cm)
Catheter size (F)
Inflatedballoondiameter (mm)
Max. size of deflatedballoon (F)
Usable length(cm)
Max. liquidcapacity(ml)
Max. recom-mendedpull force (lbs.)
Compatibleintroducer(F)
Compatibleguidewire(in.)
Fogarty arterial embolectomy catheters (tube pack)
Fogarty arterial embolectomy catheters (flat pack with syringe)
Fogarty fortis arterial embolectomy catheters
Over-the-wire Fogarty thru-lumen embolectomy catheters
Fogarty venous thrombectomy catheters
Fogarty irrigation catheters