Edificio

2
TABLE: Beam Forces Story Beam Load Case/Combo Station P V2 V3 m tonf tonf tonf Story1 B18 Comb1 0.3 -9.5369 -12.9147 0.0358 Story1 B18 Comb1 0.77 -9.5369 -12.559 0.0358 Story1 B18 Comb1 1.24 -9.5369 -12.2032 0.0358 Story1 B18 Comb1 1.71 -9.5369 -11.8475 0.0358 Story1 B18 Comb1 2.18 -9.5369 -11.4918 0.0358 Story1 B18 Comb1 2.65 -9.5369 -11.136 0.0358 Story1 B18 Comb1 3.12 -9.5369 -10.7803 0.0358 Story1 B18 Comb1 3.59 -9.5369 -10.4246 0.0358 Story1 B18 Comb1 4.06 -9.5369 -10.0689 0.0358 Story1 B18 Comb1 4.53 -9.5369 -9.7131 0.0358 Story1 B18 Comb1 5 -9.5369 -9.3574 0.0358 Story1 B18 Comb1 5 -9.5538 8.2575 -0.0517 Story1 B18 Comb1 5.47 -9.5538 8.6132 -0.0517 Story1 B18 Comb1 5.94 -9.5538 8.969 -0.0517 Story1 B18 Comb1 6.41 -9.5538 9.3247 -0.0517 Story1 B18 Comb1 6.88 -9.5538 9.6804 -0.0517 Story1 B18 Comb1 7.35 -9.5538 10.0361 -0.0517 Story1 B18 Comb1 7.82 -9.5538 10.3919 -0.0517 Story1 B18 Comb1 8.29 -9.5538 10.7476 -0.0517 Story1 B18 Comb1 8.76 -9.5538 11.1033 -0.0517 Story1 B18 Comb1 9.23 -9.5538 11.4591 -0.0517 Story1 B18 Comb1 9.7 -9.5538 11.8148 -0.0517

description

Analisis viga edificio torsion etabs

Transcript of Edificio

Beam ForcesTABLE: Beam ForcesStoryBeamLoad Case/ComboStationPV2V3TM2M3mtonftonftonftonf-mtonf-mtonf-mStory1B18Comb10.3-9.5369-12.91470.0358-0.54450.0853-23.7722Story1B18Comb10.77-9.5369-12.5590.0358-0.54450.0685-17.7859Story1B18Comb11.24-9.5369-12.20320.0358-0.54450.0517-11.9667Story1B18Comb11.71-9.5369-11.84750.0358-0.54450.0349-6.3148Story1B18Comb12.18-9.5369-11.49180.0358-0.54450.018-0.8301Story1B18Comb12.65-9.5369-11.1360.0358-0.54450.00124.4875Story1B18Comb13.12-9.5369-10.78030.0358-0.5445-0.01569.6378Story1B18Comb13.59-9.5369-10.42460.0358-0.5445-0.032414.621Story1B18Comb14.06-9.5369-10.06890.0358-0.5445-0.049219.4369Story1B18Comb14.53-9.5369-9.71310.0358-0.5445-0.06624.0857Story1B18Comb15-9.5369-9.35740.0358-0.5445-0.082828.5673Story1B18Comb15-9.55388.2575-0.05170.8776-0.14228.5159Story1B18Comb15.47-9.55388.6132-0.05170.8776-0.117724.5513Story1B18Comb15.94-9.55388.969-0.05170.8776-0.093420.4194Story1B18Comb16.41-9.55389.3247-0.05170.8776-0.069116.1204Story1B18Comb16.88-9.55389.6804-0.05170.8776-0.044911.6542Story1B18Comb17.35-9.553810.0361-0.05170.8776-0.02067.0208Story1B18Comb17.82-9.553810.3919-0.05170.87760.00372.2203Story1B18Comb18.29-9.553810.7476-0.05170.87760.028-2.7475Story1B18Comb18.76-9.553811.1033-0.05170.87760.0523-7.8825Story1B18Comb19.23-9.553811.4591-0.05170.87760.0766-13.1847Story1B18Comb19.7-9.553811.8148-0.05170.87760.1009-18.654

Hoja1