275 Boiler Control - One TN4, Four Modulating Boiler & DHW / Setpoint
ECOLOG Datalogger Series(details on page 8) Part No. 2421-W TN4, white housing Part No. 2422 TN4-L,...
Transcript of ECOLOG Datalogger Series(details on page 8) Part No. 2421-W TN4, white housing Part No. 2422 TN4-L,...
www.elpro.com
DataloggingCompany
ECOLOG Datalogger Series
2 • 3
ECOLOG TN4
ECOLOG TN4-L
ECOLOG TN3-P
ECOLOG TN2
ECOLOG TN
•4channeldatalogger(NTC)for externalsensors,withLEMO
connector•Measuringrange:-50°C..140°C•Programmablealarmfunctionswith
alarmoutput•Keypadfordataloggercontroland configuration
•2digitalinputs•Directprintoutofmeasuredvaluesand
alarmdataatprotocolprinter
Part No. 2420-WTN2,whitehousing
ECOLOGTNareuniversal,multi-purposeinstrumentsformonitoring
anddocumentingtemperatures.Thepossibleapplicationsforthese
measuringinstrumentsarepracticallylimitless,rangingfrom
monitoringroomsorproductionprocessestodocumentingtransport
conditions.
Versatileconfigurationpossibilities,sensorsforvariousapplications
andacomprehensiveassortmentofaccessoriesensurereliable
solutionsforeveryrequirement.
& SPECiaL aCCESSOriES
• 2channeldatalogger(NTC) withinternalsensor•Measuringrange: –Externalsensor:-50°C..140°C –Internalsensor:-35°C..55°C• Programmablealarmfunctions withalarmoutput
• Specialfunctionsviamultifunction connector: –Externalmeasuringstart –Alarmreset•1digitalinput
•3channeldatalogger(NTC)withinternalsensor
•Measuringrange:•Externalsensor:-50°C..140°C•Internalsensor:-35°C..55°C
•Programmablealarmfunctionswithalarmoutput
•Specialfunctionsviamultifunction connector:
•Externalmeasuringstart•Alarmreset
•1digitalinput•Directprintoutofmeasuredvalues andalarmdataatprotocolprinter
Part No. 2420-P TN3-P,redhousingPart No. 2420-PWTN3-P,whitehousingPart No. 2420-PExTN3-P, withExapprovalin accordancewithATEX (detailsonpage8)
•4channeldatalogger(NTC)forexternalsensors
•Measuringrange:-50°C..140°C•Programmablealarmfunctionswith
alarmoutput
•Keypadfordataloggercontrolandcon-figuration
•2digitalinputs•Directprintoutofmeasuredvaluesand
alarmdataatprotocolprinter
Part No. 2421 TN4,redhousing
Part No. 2421-Ex TN4,withExapprovalinaccordancewithATEX(detailsonpage8)
Part No. 2421-W TN4,whitehousing
Part No. 2422TN4-L,redhousing
Part No. 2422-Ex TN4-L,withExapprovalinaccordancewithATEX(detailsonpage8)
Part No. 2422-WTN4-L,whitehousing
Part No. 2420 TN2,redhousing
Part No. 2420-Ex TN2,withExapprovalinaccordancewithATEX(detailsonpage8)
•2-4channeldataloggerswithinternalandexternalsensors
•Principleofmeasurement: resistancemeasuring(NTC)•Largedisplayforcurrentmeasured valuesandalarminformation•Inputsforrecordingdigitalstates•EvaluationwithelproLOGANALYZE softwareatPC•Programmablerecordinginterval•One-yearmemorycapacityfor64’000
measuredvalues
•Keypadondatalogger(TN4,TN4-L):•Displaysmeasuredvaluesandalarms•Controlsprintingfunctions•Testsalarmoutput•Resetsalarmoutput•Startslogging
•Openinterfaceforcommunicationwithotherdevices(TN3-P,TN4,TN4-L)
•Lowenergyconsumptionduetopower-savemode
•AlsoavailablewithExapproval(detailsonpage8)
MOUNTiNG braCkETS NTC TEMPEraTUrE PrObES applications
Documenting transport conditionsLoggingtemperaturesduringlow-temperatureandrefrigeratedtransports.Aprinter,connecteddirectlyattheECOLOGdatalogger,makescomplete,on-locationtransportdocumentationpossible.
analyzing evironmental dataUsingrobustECOLOGdataloggerswiththeirversatileaccessoriesareusedforlong-termanalysisofenvironmentaldata.
ECOLOGdataloggerscanbeusedforawidevarietyofapplications:
Documenting pharmaceutical product storageDocumentingstorageconditionsoftemperature-sensitivepharmaceuticalproducts.ELPROsystemsarequalifiableandareavaluabletoolwhenitcomestofulfillingGMP/GLPregulations.
recording clean room conditionsUsingELPROsystemstoprovidedocumentedevidenceofthespecifiedclimaticconditionsincleanroomsandlaboratories.
Monitoring museum climateControllinganddocumentingclimaticstorageconditionsforvaluable,antiqueobjects.
Monitoring food industry processesUsingELPROdataloggersystemsastoolstodocumenttemperaturesinHACCPprocesses.
Resistorprobe3K3A1Bfortemperaturerange-50°C..140°C:
Part No. 3090-LxxUniversalsensor,LS=50mm,D=6mmPart No. 3091-LxxUniversalsensor,LS=150mm,D=6mm
Part No. 3095-LxxSensorforTwinlockmeasuringnipple,LS=70mm,D=3.4mm
Part No. 3010-LxxNeedleprobe,LS=100mm,D=4mm
Part No. 3041-LxxSurfaceprobe,Sensorsurfacearea6x30mm
Part No. 3021-LxxNeedleprobewithhandle,LS=100mm,D=4mm
Part No. 3025-L00Submergibleprobewithimmersionsleeve
Part No. 3094-LxxTemperaturerange-50°..105°C,withroundcable,LS=20mm,D=5mm
Part No. 3093-LxxTemperaturerange-50°..105°C,withflatcable,LS=20mm,D=5mm
Part No. 3060Plug-inprobe
Part No. 3055-LxxDropprobe,D=2.5mm
Part No. 3050-LxxMagnettemperatureprobe,D=22mm,H=12mmPart No. 2315-b
Built-inprinterwithbracket
Part No. 2804-CrMountingbracketwithterminalsandRS232interface
Part No. 2804-C MountingbracketwithterminalsPart No. 2804-C-Ex withExapproval
Part No. 2560-aSetforcoolingtransporterECOLOGTN3-Pwithprinterinwatertightbox
Part No. 3032-iSMultifunctionconnectorforexternalstartandforsettingthedigitalinputforTN2/TN3-P
Part No. 3032-VNCouplerDB15LEMO
See page 7 for additional accessories that can be used for the entire ECOLOG family.
COUPLErS
LOGGiNG
4 • 5
ECOLOG TH1
ECOLOG TH2
ECOLOG TH & SPECiaL aCCESSOriES
Foruserswhosethighstandards,theECOLOGTHistheideal
instrumentforloggingtemperatureandrelativehumidity.High
reliabilityandaprovenmeasuringtechnique,versatileconfiguration
possibilitiesandthecomprehensiveassortmentofaccessoriesare
someofthereasonsforthesuccessoftheECOLOGTHinamultitude
ofindustriesandapplications.
•Temperatureandrel.humiditylogging-withinternalandexternalsensors
•Principleofmeasurement:T:resistancemeasuring(NTC),rH:capacitive
•Implementationofcalibratedandreplaceablecombi-sensors
•Largedisplayforcurrentmeasuredvaluesandalarminformation
•Inputsforrecordingdigitalstates•EvaluationwithelproLOGANALYZE softwareatPC•Programmablerecordinginterval•One-yearmemorycapacityfor64‘000
measuredvalues
•Keypadatdatalogger:•Displaysmeasuredvaluesandalarms•Controlsprintingfunctions•Testsalarmoutput•Resetsalarmoutput•Startslogging•Measuredvaluemarking
•Openinterfaceforcommunicationwithotherdevices
•Lowenergyconsumptiondueto power-savemode•AlsoavailablewithExapproval (detailsonpage8)
•4channeldataloggerfor2xtemperatureandrel.humidity
•Twoexternalcombi-sensors canbeconnected•Inputforexternaltemperature
sensor(NTC)
•Measurementrange:•Externalcombi-sensor:-35°C..70°C, 0..100%rH(Part.No.3087)•-35°C..110°C,0..100%rH (PartNo.3087-B)•ExternaltemperaturesensorNTC -55°C..140°C
•Programmablealarmfunctionswithalarmoutput
•Keypadfordataloggercontroland configuration•Alarmresetviakeypad•1digitalinput•Directprintoutofmeasuredvaluesand
alarmdataatprotocolprinter
Part No. 2426-W TH2,whitehousing
Part No. 2426 TH2,redhousing
Part No. 2426-Ex TH2,withExapprovalinaccordancewithATEX(detailsonpage8)
•4channeldataloggerfor2xtemperatureandrel.humidity
•Integratedcombi-sensorfortemperatureandrel.humidity
•Externaltemperaturesensor(NTC) canbeconnected•Measurementrange:
•Internalcombi-sensor: -35°C..55°C,0..100%rH•Externalcombi-sensor: -35°C..70°C,0..100%rH (PartNo.3087) -35°C..110°C,0..100%rH (PartNo.3087-B)•Externaltemperaturesensor: -55°C..140°C
•Programmablealarmfunctionswithalarmoutput
•Keypadfordataloggercontroland configuration•1digitalinput•Directprintoutofmeasuredvaluesand
alarmdataatprotocolprinter
Part No. 2423 TH1,redhousingwithstandardsensor
Part No. 2423-Ex TH1,withExapprovalinaccordancewithATEX(detailsonpage8)
Part No. 2423-W TH1,whitehousing
withstandardsensor
StandardT/rHsensorasexternalprobe
1externaland1internalT/rHsensorCablelengthmaximum20meters
2externalT/rHsensorsTotalcablelengthmaximum20meters
rH:
Configuration examples for ECOLOG TH
D=
LS=
Sensor lengths and diameters
Temperaturesensors(NTCandPT100)areusuallyavailableinvariouslengthsorwithvariousdiameters.Whenanorderismade,the‘x’intherespectivepartnumberisreplacedwiththerelativecablelengthinmeters.
LengthSensorinmm
Diameterinmm
See page 7 for additional accessories that can be used for the entire ECOLOG family.
HOUSiNGT / rH SENSOrS elproLOG aNaLYZE software
Part No. 3087Plug-incombi-sensortemperature/humidityT-35°C..+70°C,rH0%..100%Part No. 3087-bPlug-incombi-sensortemperature/humidityT-35°C..+110°C,rH0%..100%
Histogramwithmanualorautomaticgrouping.
Tablewithcoloredmarkingsshowingthresholdviolations.
Datawithmarkedthresholdvaluesandstatisticinformation.
TheelproLOG aNaLYZEsoft-
warecanbeusedforallELPRO
dataloggermodels,allowingfast
andefficientevaluationoflogged
data.WithelproLOG aNaLYZE
andafewmouseclicks,youcan
createmeaningfulandclearly
laidoutdocumentationofyour
climaticvaluesingraphortable
format.
Whileobservingregulatory
compliancetoFDA21CFRPart
11,GMP,GAMP5andGLP,the
validatedelproLOG aNaLYZE
QLSsoftwareoffersyouallthe
securityyouneedformonitoring
yourregulatedenvironments.
Thedetailedvalidationmanual
containsIQ/OQtemplatesfor
softwareanddataloggersaswell
assampleSOPs.
elproLOG aNaLYZE/aNaLYZE
QLSismultilingual,supporting
German,English,French,Spanish
andItalian.
ExtensivequalificationandvalidationmanualwithtemplatesforIQ/OQandsampleSOPs.
Part No. 3215-SxxExtensioncableforECOLOGTH1,TH2
ExTENSiON CabLE
Part No. 2805-CrMountingbracketwithRS232interfaceandconnectionsfor2externalcomibsensorsT/rHPart No. 2805-C-ExwithExapproval
MOUNTiNG braCkET
NTC TEMPEraTUrE PrObE
Resistorprobe3K3A1Bfortemperaturerange-50°C..140°C:SeeECOLOGTNonpage3. Part No. 2352-a
Protectivehousingforsteamcleaning
Part No. 2804-GProtectivelid
Part No. 2804-FProtectivecagefortransportmonitoring
ECOLOG TP4-L
ECOLOG TP2
6 • 7
ECOLOG TP
Part No. 3168-LxxTightfoodstuffprobe,DINA,-50°C..180°C,synthetic,LS=120mm,D=4mm
TheECOLOGTPstandsforprecisionmeasuringandevaluatingof
temperaturesinthe-200°C..550°Crange.Thisuniversaldatalogger,
basedonthestandardizedPT100measuringtechniqueandwitha
comprehensiveassortmentofsensorsandaccessories,canbeusedfor
widespreadapplicationsrangingfrommonitoringlowtemperatureto
documentingdryingprocesses.
MOUNTiNG braCkETSCOUPLErS
•2-4channeldataloggers•Principleofmeasurement: 4-wirePT100inaccordancewith
IEC751/EN60751•Digitalinputsandevaluationwith
elproLOGANALYZEsoftwareatPC•Largedisplayforcurrentmeasured
valuesandalarminformation•Programmablerecordinginterval•One-yearmemorycapacityfor64‘000
measuredvalues
•Keypadatdatalogger:•Displaysmeasuredvaluesandalarms•Controlsprintingfunctions•Resetsalarmoutput•Startslogging
•Openinterfaceforcommunicationwithotherdevices
•Lowenergyconsumptionduetopower-savemode
•AlsoavailablewithExapproval(detailsonpage8)
•2channeldatalogger(PT100)for externalsensors•Measuringrange:-200°C..550°C•Programmablealarmfunctionswith
alarmoutput
•Keypadfordataloggercontroland configuration•1digitalinput•Directprintoutofmeasuredvaluesand
alarmdataatprotocolprinter
Part No. 2425-2T TP2,redhousing
Part No. 2425-2TEx TP2,withExapprovalinaccordancewithATEX(detailsonpage8)
Part No. 2425-2TW TP2,whitehousing
•4channeldatalogger(PT100)for externalsensors,withLEMO
connector•Measuringrange:-200°C..550°C•Programmablealarmfunctionswith
alarmoutput
•Keypadfordataloggercontroland configuration•1digitalinput•Directprintoutofmeasuredvaluesand
alarmdataatprotocolprinter
Part No. 2425TP4-L,redhousing
Part No. 2425-Ex TP4-L,withExapprovalinaccordancewithATEX(detailsonpage8)
Part No. 2425-W TP4-L,whitehousing
Part No. 2801-CrMountingbracketwithterminalsPart No. 2801-C-ExwithExapproval
Part No. 3032-VNPDB15LEMOconnectorforsimpletemperatureprobereplacing
ResistorprobesEN60751;temperaturerangetype-dependingfrom-200°C..550°CContactusforinformationaboutadditionalPT100temperatureprobesorvisitwww.elpro.com.
PT100 TEMPEraTUrE PrObES
Part No. 3167-LxxDIN B probe, -80°C..105°C, synthetic, molded, LS = 20 mm, D = 5 mm
Part No. 3164-LxxDINAprobe,-50°C..260°C,stainlesssteel,pointed,LS=100mm,D=4mm
Part No. 3165-LxxDINAMLprobe,-200°C..500°C,stainlesssteel,bendable,LS=350mm,D=3mm
Part No. 3181-LxxDINAprobe,steam-resistant,autoclavable,-200°C..180°C,LS=100mm,D=5mm
Part No. 3163-LxxDINAprobe,-90°C..260°C,stainlesssteel,LS=100mm,D=4mm
Part No. 3174-LxxMLprobe,-80°C..350°C,stainlesssteel,bendable,LS=50mm,D=2mm
Part No. 3169-LxxDINAprobe,0°C..500°C,stainlesssteel,glassfibercable,LS=50mm,D=6mm
Part No. 3173-LxxDINAscrew-inprobe,-50°C..120°C,R1/8’’,LS=24mm,D=3mm
Part No. 3171-LxxSurfaceprobe,0°C..180°C,6x10x35mm,canbescreweddownwithbondingfoil(upto+80°C)
Part No. 3160DINAplug-onprobe,-35°C..55°C,LS=30mm,D=10mm
Part No. 3159-LxxFoilprobe,class0.5,0°C..180°C
& SPECiaL aCCESSOriES
ECOLOG accessories for all models
MOUNTiNG braCkETS CONNECTOrS TEMPEraTUrE SENSOrSaCCESSOriES
aLarMiNG
Part No. 3211-yMountingflange
Part No. 3211-byyScrewclamp
Part No. 2317-USbUSB-RS232adapterforconnectingdataloggertoPCUSBport
Part No. 2318PCdatacableforPCevaluation
Part No. 3095-TMeasuringnippleTWINLOK
Part No. 2820ReplacementbatteryforECOLOGdata-logger,setwith2batteries,storableforatleast5years
Part No. 2350-xCasingIP66
Part No. 2804-aMountingplate
Part No. 2804-bHoldingplatewithbracketforconnector
Part No. 2804-EHoldingplatepadlockable(locknotincluded)
Part No. 2311-bAlarmflashxenonflashred
PartNo.2311-CAlarmflashwithsiren
Part No. 2312AlarmflashforloggerandbracketwithExapproval
Part No. 2341-bAutomatictelephonedialunit(example)
Measurement relative humidity
Accuracy(@23°C) Hysteresis(10-90-10%rH) ±1.5%rH <1%rH
Part No. 3202-2Pb / Part No. 3202-4PbLEMOconnector,2-pinor4-pinmounting
Part No. 3032-bDB15connector,incl.customer-specificassembly,numberofcablesislimited
Part No. 3034DB15connectorforself-mounting
aDaPTErSHOUSiNG baTTErY
Temperature measurement TPx Temperature measurement TNx and THx(onlydataloggeratroomtemperature) Measurementrange Resolution Linearity(k=1) -200°C .. -101°C 0.2°C ±0.3°C -100°C .. 399°C 0.1°C ±0.2°C 400°C .. 499°C 0.1°C ±0.3°C 500°C .. 550°C 0.2°C ±0.5°C
(dataloggerwithtemperaturesensor,loggeratroomtemperature) Measurementrange Resolution Accuracy(U95;k=2) -50°C .. -31°C 0.1°C ±0.6°C -30°C .. -16°C 0.1°C ±0.4°C -15°C .. -1°C 0.1°C ±0.3°C 0°C .. 49°C 0.1°C ±0.2°C 50°C .. 99°C 0.1°C ±0.3°C 100°C .. 125°C 0.1°C ±0.6°C 126°C .. 140°C 0.1°C ±0.9°C
GMP/GLP/GAMP5
EG/EU
HACCP
ISO9001:2000
ATEX
CE
EN12830/EN13485/EN13486
GZ1480
8
SEE 00 aTEx 3115ii 2 GEx ib iib T4 1258
Anschlussdatendeseigen.Steckers:Securitéintrinsèqueinterface:Condataoftheint.safeinterface:Manual EZ-7003b
Made in Switzerland – for 20 years
SGScertificateno.CH98/0013
ApprovalforEXprotectionzone1EN60079-0:2006EN60079-11:2007,EN1127-1:2007
EN61000-6-2:2006andEN61000-6-4:2006
Temperaturerecorderfortransport,storageanddistributionoffoodstuffs
ExceptionalapprovalforcalibrationGZ1480/2000from10.4.2000,BEV,Austria
Ex aPPrOVaL DirECTiVES & STaNDarDS
ii 2 G
II DevicecategoryIIintendedforuseinall
potentiallyexplosiveatmospheresapartfrom
mines.
2 Category2,suitableforuseinzone1
(occasionalexplosionhazard)aswellasin
zone2(rareexplosionhazard)
G Atmospherewithexplosionhazardarising
fromgasesandvaporsbutnotfromdust
Ex ib iib T4
Ex Explosionprotectiontypeaccordingto
Europeandirectives:EN50014:1997+A1
+A2andthedirectivesforspecialtypesof
protectionagainstignition
ib Typeofprotectionforintrinsicsafetyagainst
ignition:categoryibwith1failureaccording
toEN50020:2002
IIB Useinallpotentiallyexplosiveatmospheres
apartfrommines:groupIIsubclauseB
T4 TemperatureclassT4:max.surface
temperature135°withasafetymarginof5
Kelvinforpermanentlyhotsurfaces
T4appliesforcompoundmaterialswithan
ignitiontemperaturet>135°C,essentially
ethyletherandethanol,whichareusedfor
industrialproductionofsyntheticsandsol-
vents
• ISO9001qualitysystem
• Vendorandinternalaudits
• Expertsystems
• Ownproductionand
development
• Owncalibrationlaboratory
• Modernfacilities
• Dataloggerservicesince1989
• Calibrationaccordingtoallstandards
• Repairserviceforall
products
• Customercalibrationservice
• IQ/OQqualifications
• Temperaturemapping
• Worldwidedistributors
• ReturnofELPROunitsand
batteriesforeco-friendly
disposal
Contact us for additional information about ELPrO dataloggers and systems or visit us at www.elpro.com.
SErViCE & QUaLiTY
Softwarevalidationinaccordancewith21CFRPart820,ElectronicRecords21CFRPart11,21CFRPart210/211,21CFRPart110,21CFRPart58
Regulation(EC)37/2005Directive2002/95/EC(RoHS)
HazardAnalysisCriticalControlPoints
iNTEGraTED rEGULaTiONSaND rECOMMENDaTiONS
all ECOLOG dataloggers are available with Ex approval.
EZ10
02Eb
ExPLaNaTiON OF iCONS
21CFRPart11
Temperature|humidity|pressuremeasurement
Gas|wind|comfortmeasurement|Universal4-20mAinputs
Networks|Bluetooth
Displayalarm|alarmoutput|centralalarming
IPprotectiveclass
Ex-approved
xxx|xxx
ELPrO Services, inc.
210MillcreekRoad
Marietta,OH45750
USa
T 740568.9900
F 740569.9399
web www.elpro.com
ELPrO Uk Ltd
Unit 1, Allen’s Yard
Nyton Road
Aldingbourne, Chichester
West Sussex PO20 3UA
United Kingdom
T +44 (0)1243 544 545
F +44 (0)1243 210 132
web www.elpro.com
ELPrO-bUCHS aG
(headoffice)
CH9470BuchsSG
Switzerland
web www.elpro.com