Ecodry 3DK...Ecodry 3DK Closed Loop Adiabatic Liquid Cooler Get the world’s most efficient cooling...

4
Ecodry 3DK Closed Loop Adiabatic Liquid Cooler Get the world’s most efficient cooling – optimized for your needs. Ecodry has saved water, energy, chemicals and maintenance time for thousands of facilities worldwide. And now, the next generation is here – providing even greater sustainability, performance and adaptability.

Transcript of Ecodry 3DK...Ecodry 3DK Closed Loop Adiabatic Liquid Cooler Get the world’s most efficient cooling...

Page 1: Ecodry 3DK...Ecodry 3DK Closed Loop Adiabatic Liquid Cooler Get the world’s most efficient cooling – optimized for your needs. Ecodry has saved water, energy, chemicals and maintenance

Ecodry

3DKClosed Loop Adiabatic Liquid Cooler

Get the world’s most efficient cooling – optimized for your needs. Ecodry has saved

water, energy, chemicals and maintenance

time for thousands of facilities worldwide. And

now, the next generation is here – providing

even greater sustainability, performance and

adaptability.

Frigel Asia Pacific Bang Pakong (Bangkok), Thailand P +66 3857 7799 E [email protected]

Frigel Australia Pty Ltd Braeside Victoria, Australia P +613 9587 8047 E [email protected]

Frigel GmbH Rheinfelden, Germany P +49 7623 748 7245 E [email protected]

Page 2: Ecodry 3DK...Ecodry 3DK Closed Loop Adiabatic Liquid Cooler Get the world’s most efficient cooling – optimized for your needs. Ecodry has saved water, energy, chemicals and maintenance

3

4

5

Ecod

ry3D

K PROVEN Advantages Trusted by top-performing companies

worldwide. As your needs continue to evolve,

we continue to improve on our unique dry-cooling

technology to support your success.

SustainabilityReduce Water Use up to 95% vs. a Cooling Tower With no evaporation of process water, the Ecodry 3DK keeps your

water clean and your equipment scale-free. It often operates

without consuming any water – activating the adiabatic system

only on hotter days to pre-cool incoming air.

Saving 4 million liters (1 million gallons ) of water per year

for the average 350 kW (100 ton) system

Greatly reducing chemical requirements and completely

eliminating chemical discharges

High-temperature ambient air passes through the lower adiabatic chamber.

In the chamber, nozzles create a fine mist of water from a separate source.

Humidification of the air reduces the temperature prior to contact with the heat exchangers.

Patented design prevents water drift outside the chamber, eliminating heat exchanger scaling and avoiding the risk of proliferation of bacteria, such as Legionella. In addition, the absence of stagnant water helps to prevent bacterial development.

To ensure consistent cooling, the control system continuously adjusts the amount of water sprayed. The heat exchangers, meanwhile, remain completely dry.

1

2

Internationally Patented Adiabatic Chamber

Adiabatic chamber

Air Out

Air In

HeatExchanger

Adiabatic Chamber(operates onlywhen required)

Cooled Air

Page 3: Ecodry 3DK...Ecodry 3DK Closed Loop Adiabatic Liquid Cooler Get the world’s most efficient cooling – optimized for your needs. Ecodry has saved water, energy, chemicals and maintenance

Let’s Discuss Your ApplicationContact the Frigel team today to get the world’s most efficient cooling – optimized for your needs.

PerformanceReduce Energy Use Nearly 95% vs. an Air Cooled Central Chiller Providing clean water at the right temperature to process

machines year round, closed-loop cooling inherently minimizes

maintenance and increases the efficiency of your operation.

3DK builds on these benefits by incorporating variable speed DC

brushless motors and other features into a quiet-operating design

that delivers:

Minimum energy consumption – up to 28% lower with available fan exhaust diffusers,

plus “free cooling” capability when conditions permit

Precise water temperature, maintained by responsive controls that continuously adjust

fans and adiabatic chamber activation as needed

Maximum uptime, thanks to scale-free operation, new acrylic coated heat exchanger and

durable construction with stainless steel, copper, brass and aluminum components

AdaptabilityOptimal Operation for Your Location and Application The 3DK has everything you need to maintain precise cooling

temperature and maximize uptime, regardless of climate,

system demands or space constraints.

From Seaside to Tropical to Arctic Hotter climates - New adiabatic booster

system for temperature ranges similar to

those of cooling towers (patent pending)

Milder environments – Parallel or series

heat exchanger configurations, selected

by Frigel for optimum performance

Freezing climates – Self-draining coils with

recirculation pump stations for non-glycol

applications

Small FootprintsSpace-saving roof panels allowing

units to be placed only 600 mm

(2 feet) apart

Air flow optimized in tight spaces with

extended support legs

Space reduced up to 30%

Your Operation’s Needs Are at the Forefront

From detailed cost analysis to robust engineering to steadfast service and support, Frigel is here to help you achieve just the right solution for optimal cooling performance in your facility.

Glycol system Self-draining system

Page 4: Ecodry 3DK...Ecodry 3DK Closed Loop Adiabatic Liquid Cooler Get the world’s most efficient cooling – optimized for your needs. Ecodry has saved water, energy, chemicals and maintenance

www.frigel.com

Comprehensive. Expandable. Convenient. Complete Systems Including Available Global Internet Service

Bulletin: SALES-LR.3DK.LT.ENG.0000.00.04 | Effective: February 01, 2016 | Supersedes: June 22, 2015

Seamlessly integrated Aquagel pump stations, stainless steel reservoirs and stainless steel filters

Easy to expand to meet growing needs

PMR control center for managing the entire system from one convenient location

Ethernet connection allows Frigel service technicians to monitor and troubleshoot from locations worldwide

GLOBAL HEADQUARTERS

Frigel Firenze S.p.A. Scandicci (Fl), Italy P +39 055 72209 20 E [email protected] E [email protected]

Frigel Custom Cooling Solutions s.r.l. Ronco Briantino (MB), Italy P +39 039 53000 22 E [email protected]

Frigel North America East Dundee (Chicago), IL USA P +1 847 540 0160 E [email protected]

Frigel Latino América Ltda Iracemápolis (Sao Paolo), Brazil P +55 19 3010 1900 E [email protected]

Frigel Intelligent Energy Solutions S.r.l.Gallarate (Milan), ItalyP +39 033 17846 49E [email protected]

Frigel Asia Pacific Bang Pakong (Bangkok), Thailand P +66 3857 7799 E [email protected]

Frigel Australia Pty Ltd Braeside Victoria, Australia P +613 9587 8047 E [email protected]

Frigel GmbH Rheinfelden, Germany P +49 7623 748 7245 E [email protected]

Frigel recommends that adiabatic dry coolers be used and maintained in full compliance with all applicable local and national laws, codes, standards and the requirements of all relevant authorities.