Eclipse Series Intruder Alarm Rangesarian.ir/fa/images/products/pdf/Intruder keypad... · Eclipse...

4
Eclipse Series Intruder Alarm Range

Transcript of Eclipse Series Intruder Alarm Rangesarian.ir/fa/images/products/pdf/Intruder keypad... · Eclipse...

Page 1: Eclipse Series Intruder Alarm Rangesarian.ir/fa/images/products/pdf/Intruder keypad... · Eclipse 32 has 8 physical inputs on board for connecting of detectors; The full configuration

Eclipse SeriesIntruder Alarm

Range

Page 2: Eclipse Series Intruder Alarm Rangesarian.ir/fa/images/products/pdf/Intruder keypad... · Eclipse 32 has 8 physical inputs on board for connecting of detectors; The full configuration

Eclipse 8

LCD32

System Serial Bus

LED8

LAN / GPRS

Direct programming

ARGUSGSM module:

Voice messaging;SMS messaging;

Device control

Voice Messaging(PSTN)

SensoMAGFire Alarm

Series

TITAN Series SR300 Siren

Remote programmingAJAX SP PRO

Web Application

Eclipse 8 is an alarm panel with 8 zone inputs for security of small residential, commercial or office premises. The control management of the panel is available via keyboard or proximity card reader. Full programming is done via keyboard or directly with ProsTE software. The installer can choose between 3 alternative types of programing - by addresses, by operations or tree structure menus. The panel has a built in digital communicator and is compatible with wide range of detectors, communica-tion modules and control devices.

Zones ...................................................8 Balancing of zones ..............................1 or 2 balancing resistorsConnection styles ................................5 typesAreas ...................................................1Outputs ................................................4 low current (up to 100mA) + 1 powerful (up to 1A)Access Codes ......................................4 digit; 8 user (1 manager), 1 engineerMemory LOG .......................................256 events with date and timeDigital Communicator ..........................built in; 2 telephone numbers; CIA and Contact IDProgramming .......................................3 types - by addresses, by operations, tree structureAccess Control .....................................via proximity readers;

Eclip

se 8

Basic Information

System Architecture

Functional Specifications

Page 3: Eclipse Series Intruder Alarm Rangesarian.ir/fa/images/products/pdf/Intruder keypad... · Eclipse 32 has 8 physical inputs on board for connecting of detectors; The full configuration

Eclipse 32/99

ARGUSGSM module:

Voice messaging;SMS messaging;

Device control

Direct programming

Voice Messaging(PSTN)

LAN / GPRS

Proxi Reader LCD32 LCD32 SLED32LED16

Zone Expander PGM Expander

System Serial Bus

Wireless Expander (soon)

SensoMAGFire Alarm

Series

TITAN Series SR300 Siren

Remote programmingAJAX SP PRO

Web Application

Eclipse 32 is up to 32 zone control panel appropriate for security of medium sized commercial prem-ises and offices. The panel supports 8 undependable areas (partitions) with individual programming. Eclipse 32 has 8 physical inputs on board for connecting of detectors; The full configuration of 32 zones can be realized with doubling zone connection (16 logical zones on the control PCB) and 1 Zone expander for 8 zones (16 logical zones) or without zone doubling with 3 zone expanders. The installer can choose between 3 alternative types of programing - by addresses, by operations or tree structure menus.

Zones ................................................8 on board; expandable to 32Balancing of zones ...........................1 or 2 balancing resistors; doubling zone connectionAreas ................................................8Outputs .............................................4 low current (up to 100mA) + 1 powerful (up to 1A)Access Codes ...................................4/6 digit; 64 user, 4 maintenance, 1 engineerMemory LOG ....................................1024 events with date and timeDigital Communicator .......................4 telephone numbers; built in; CIA and Contact IDProgramming ....................................3 types - by addresses, by operations, tree structureAccess Control ..................................via proximity readers; time slotsConnection styles .............................9 types

Eclipse 32Basic Information

System Architecture

Functional Specifications

Page 4: Eclipse Series Intruder Alarm Rangesarian.ir/fa/images/products/pdf/Intruder keypad... · Eclipse 32 has 8 physical inputs on board for connecting of detectors; The full configuration

Eclipse panels are designed to cover all the requirements of EN50131-1/3 Grade 2 standard and to meet the highest user needs for security and monitoring of pro-tected areas. Three types of programming with address, operation and text menu structure platforms are available, helping the installer to choose the most suitable to work with. Direct PC programming via software.

Features Eclipse 8 Eclipse 32 Eclipse 99 (soon)

On Board Zones 6 + 2 keypad zones 8 8 Max. Zones 8 32 99Zone Doubling - Yes YesOn Board PGM Outputs 5 5 5Max. PGM Outputs 5 32 99Relay output - - YesTwo - wire fire zone - Yes YesSecurity Areas 1 8 16Time Slots - Yes YesMultilanguage LCD Yes Yes YesUsers 8 64 99Events LOG 256 1024 5000Power Supply 2A 2.5A 2.5AMax. Bus Devices 2 30 64

LED KeyboardsRemote keyboards for complete programming of the Eclipse 8 and Eclipse 32 control pan-els. LED indication for 8/16/32 zones and 1/2/8 security areas. Quick buttons for arming and disarming the system.

14A Srebarna Str., 1407 Sofia, BULGARIA; Tel.: +359 2 9694 800; Fax: +359 2 9625 213www.teletek-electronics.com; [email protected]

LCD 32• LCD display • 8 Areas, 32 Zones• Optional built-in proxi reader.

LCD 32 Sensitive• LCD display • 8 Area, 32 Zones• Sensitive control buttons. • Built-in proxi reader.

LED 16• LED display• 2 Areas• 16 zones

LED 32• LED display• 8 Areas• 32 zones• Optional built-in proxi reader.

LED 8• LED display• 1 Areas• 8 zones

LCD KeyboardsRemote keyboards for complete programming of the Eclipse 8 and Eclipse 32 control pan-els supporting address and text menu structures of the menus. Large 32 characters LCD display. Quick buttons for arming and disarming the system.