Echocardiography and Magnetic Resonance Imaging for...

31
Echocardiography and Magnetic Resonance Imaging for detection of Coronay Artery Disease Hans-Marc J. Siebelink MD PhD Leiden University Medical Center Cardiology, Non-Invasive Imaging Leiden, The Netherlands

Transcript of Echocardiography and Magnetic Resonance Imaging for...

Page 1: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Echocardiography and

Magnetic Resonance Imaging

for detection of

Coronay Artery Disease

Hans-Marc J. Siebelink MD PhD

Leiden University Medical Center

Cardiology, Non-Invasive Imaging

Leiden, The Netherlands

Page 2: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Ischemic Cascade

Duration Ischemia

Tests: Functional vs Anatomic test?

ImpairedPerfusion

Metabolic changes

Diastolic

dysfunction

Systolic

dysfunction

ECGAngina

Infarction

Page 3: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Echocardiography MRI“working horse”

Available / bed site Not in every practice

Quick Protocol 30-60 min

Easy Technical, processing

Function (syst / diast) Function (syst / diast)

Stress function Stress function

Perfusion Perfusion

Coronary anatomy

Page 4: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

First line clinical practiceWall motion assessment

Cerqueira, Circ 2002

Vascular pattern?

Page 5: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

2D-echocardiography

Visual function

Page 6: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

3D-echocardiography

Automatic border (TomtTec®) detection on 4D volume contrast acquisitions

Page 7: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Echo wall motion abnormality

Global Apical

Idiopathic DCM Aneurysm post infarct

Page 8: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Echo wall motion abnormality

LV thrombus?

Near field artefact

Page 9: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

MRI wall motion abnormality

Inferior wall motion abnormality

Inferior infarction?

Page 10: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Regional wall motion abnormality

Suggestive CAD How to prove it?

Tissue characterisation

perfusion echo

delayed enhancement (DE) MRI

Provoke ischemia stress echo / MRI

Perfusion assessment stress echo / MRI

Page 11: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Echo tissue characterizationcontrast perfusion

4 chamber 2 chamber

Antero-apical perfusion defect infarction

Page 12: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

MRI tissue characterizationDelayed enhancement (DE)

Kim et al. Cardiovascular MRI and CT. Higgins, de Roos. Eds 2002

Page 13: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Vogel-Claussen, Radiographics 2006

DE MRI Technique

Page 14: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

DE MRI

Inferior infarction

Non-transmural?

Page 15: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

DE MRI

Inferior infarction

Non-transmural and transmural

Management?

Page 16: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Recovery LV function

Infarct transmurality predictive of recovery

Delayed enhancement MRI

Clinical practice: cutoff 50%

Infarct transmurality %

Kim R, NEJM, 2000

Page 17: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Viability and prognosis

Allman, JACC 2002

Page 18: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Dobutamine stress echo

Recruitment wall motion pos identification

Beta adrenergic stimulation

Biphasic response

Baseline:wall motion abnormalities

Low dose: improvement wall motion viability

(High dose: deterioration wall motion) ischemia

Angina, ECG

Highly operator dependent, image quality

Page 19: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Dobutamine stress echo

No wma no ischemia

Rest

10 γ

40 γ

Recovery

Page 20: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Dobutamine stress echo

Angina, ST , wma Ischemia

Rest 20 γ

10 γrecovery

Recovery

Page 21: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Dobutamine stress MRI

Recruitment wall motion pos identification

Beta adrenergic stimulation

Biphasic response

Baseline:wall motion abnormalities

Low dose: improvement wall motion viability

(High dose: deterioration wall motion) ischemia

Angina, ECG not applicable

Less operator dependent, image quality

Page 22: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

basal

mid

apical

protocol: compare cine-series

rest dobutamine

Dobutamine stress MRI

Courtesy PRM van Dijkman

Page 23: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Severe LAD stenosis

Dobutamine 20γ Dobutamine 40 γWorseningwall motion

Mild septalhypokinesia

Dobutamine stress MRIRest: severe hypokinesia anteroseptal region

Courtesy PRM van Dijkman

Page 24: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

basal, dobu 30 γ basal, dobu 30 γ

Dobutamine stress MRI

The use of tissue tagging

Courtesy PRM van Dijkman

Page 25: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Echo myocardial perfusion

Rest Adenosine

Perfusion defect apical septal ischemia

Page 26: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

basal mid apical

High spatial resolutionAssessment subendocardial and transmural defects

MRI myocardial perfusionnormal study

Courtesy PRM van Dijkman

Page 27: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

MRI myocardial perfusion

Courtesy PRM van Dijkman

Basal mid

Transmural perfusion defect mid inferolateral

Page 28: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

80%82%Echo perfusion

specsensFunctional tests

87%85%PET perfusion

80%81%Dobu stress echo

96%

86%

91%

87%

68%

95%Dobu stress MRI with Tagging

86%Dobu stress MRI

73%SPECT perfusion

81%MRI perfusion

77%Bicycle exercise stress test

Salerno Circ Im 2009, Marwick Heart 2003, Nagel Circulation 1999

Predictive values detection CAD

Page 29: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

MRI coronary angiography

Technically difficult

Time consuming

84% Patients successful

Proximal arteries only

Future high field?!

Page 30: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Ischemic CascadeFunctional tests for CAD

Duration Ischemia

Perfusion

impaired

Metabolic changes

Diastolic

dysfunction

Systolic

dysfunction

ECGAngina

Infarction

Echo

Nuclear

MRI

Nuclear

Echo

Nuclear

MRI

Echo

Nuclear

MRI

Echo

Nuclear

MRI

Page 31: Echocardiography and Magnetic Resonance Imaging for ...assets.escardio.org/assets/presentations/ehh2010/... · Echocardiography and Magnetic Resonance Imaging for detection of Coronay

Resume detection CAD

Echo, MRI and Nuclear all - accurate

- robust.

For your clinical practice:

Choose your modality / modalities

(no need to perform all)

Gain experience

Aim high quality