ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID...

40
ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR STENOSIS MELISSA R. CUNDANGAN, MD, FPCP, FPCC, FPSE

Transcript of ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID...

Page 1: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR

STENOSISMELISSA R. CUNDANGAN, MD, FPCP, FPCC, FPSE

Page 2: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

AORTIC STENOSIS

Page 3: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

AORTIC STENOSIS

• Obstruction to LV outflow• Decrease in aortic valve area

• Normal: 3.0 – 4.0 cm2

• Mild : 1.5-2.0 cm2

• Moderate : 1.0 – 1.5 cm2

• Severe: < 1.0 cm2

Valvular Hear Disease, Chapter 63, Braunwarld’s Heart Disease 10th Edition 2014

Page 4: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

AORTIC STENOSISCauses:• Congenital (unicuspal, bicuspal, quadricuspal)• Rheumatic• Calcific/ Degenerative

EAE/ASE recommendations for Echocardiographic assessment of valve stenosis, European Journal of Echocardiography 2009

Page 5: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

A. Evaluate the anatomy of the AV

EAE/ASE recommendations for Echocardiographic assessment of valve stenosis, European Journal of Echocardiography 2009

ECHO EVALUATION OF AORTIC STENOSIS

RCC

LCCNCCDIASTOLE

SYSTOLE

Page 6: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

fusion of RCC and NCC fusion of RCC

and LCC

ECHO EVALUATION OF AORTIC STENOSIS

Page 7: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

ECHO EVALUATION OF AORTIC STENOSIS

Page 8: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

ECHO EVALUATION OF AORTIC STENOSIS

Page 9: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

ECHO EVALUATION OF AORTIC STENOSIS

Page 10: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

ECHO EVALUATION OF AORTIC STENOSIS

B. Determine the aortic valve area by Continuity Equation

EAE/ASE recommendations for Echocardiographic assessment of valve stenosis, European Journal of Echocardiography 2009

Page 11: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

ECHO EVALUATION OF AORTIC STENOSIS

C. Determine the transaortic jet velocity• measured using continuous-wave (CW) Doppler

Valvular Hear Disease, Chapter 63, Braunwarld’s Heart Disease 10th Edition 2014

Page 12: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

ECHO EVALUATION OF AORTIC STENOSIS

D. Determine the transaortic gradient

EAE/ASE recommendations for Echocardiographic assessment of valve stenosis, European Journal of Echocardiography 2009

Page 13: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

ECHO EVALUATION OF AORTIC STENOSIS

EAE/ASE recommendations for Echocardiographic assessment of valve stenosis, European Journal of Echocardiography 2009

Page 14: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

• LOW FLOW LOW GRADIENT AORTIC STENOSIS

• PARADOXICAL LOW FLOW LOW GRADIENT AORTIC STENOSIS

Page 15: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

Baseline echoAVA: 0.96 cm2PIG: 57mmHg MG: 38 mmHg EF 31%

Page 16: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

PSEUDOSEVERE AORTIC STENOSISwill exhibit an increase in the AVA little change in transvalvular gradient in response to the

increase in transvalvular flow rate

Page 17: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

TRUE SEVERE AORTIC STENOSIS• will have no or minimal increase in AVA• marked increase in gradient when flow is increased

Page 18: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

REST AVA: 0.96cm2 MG 38 PIG: 57 EF: 31%

LOW DOSE DOBUAVA: 0.99cm2MG: 51PIG: 76EF: 41% ( 32% inc)

TRUE SEVERE AORTIC STENOSIS

Page 19: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

Paradoxical Low flow Low gradient AS• Elderly female• Associated with HTN, DMEcho Characteristics• Severely thickened and calcified AV• AVA < 1.0; MVG <40mmHg• EF ≥ 50%• Small LV cavity size (LVEDD <47mm,

LVEDV <55mL• RWT of >0.5• Impaired global longitudinal strain

<15%• SV index of <35mL/m2 ASE’s Comprehensive Echocardiography 2nd ed , 2016

Page 20: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

ECHO EVALUATION OF AORTIC STENOSIS

Hemodynamic Progression• annual decrease in valve area : 0.12 cm2/year• annual increase in jet velocity of 0.32 m/sec/year

Follow-up Echo• every year: severe AS• every 1 to 2 years for moderate AS• every 3 to 5 years for mild AS.

Valvular Hear Disease, Chapter 63, Braunwarld’s Heart Disease 10th Edition 2014

Page 21: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

MITRAL STENOSIS

Page 22: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

MITRAL STENOSIS

• most frequent valvular complication of rheumatic fever

Other causes:• Congenital• Obstruction of LV inflow by LA tumor/mass (myxoma,

thrombus, vegetation)• extensive mitral annular calcification

Page 23: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

A. Appearance of the MV and the mobility of its leaflets

ECHO EVALUATION OF MITRAL STENOSIS

EAE/ASE recommendations for Echocardiographic assessment of valve stenosis, European Journal of Echocardiography 2009

Page 24: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

B. Determine the valve area1. Planimetry

2. Pressure Half TimeMVA = 220/PHT

3. Continuity Equation

4. PISA

EAE/ASE recommendations for Echocardiographic assessment of valve stenosis, European Journal of Echocardiography 2009

ECHO EVALUATION OF MITRAL STENOSIS

Page 25: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

B. Determine the valve area1. Planimetry

2. Pressure Half TimeMVA = 220/PHT

3. Continuity Equation

4. PISA

EAE/ASE recommendations for Echocardiographic assessment of valve stenosis, European Journal of Echocardiography 2009

ECHO EVALUATION OF MITRAL STENOSIS

Page 26: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

PHT = 211MVA = 1.04cm2

PHT = 159MVA = 1.38cm2

Page 27: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

C. Determine the Mean Valve gradient

ECHO EVALUATION OF MITRAL STENOSIS

Page 28: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

ECHO EVALUATION OF MITRAL STENOSIS

Page 29: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

ASSOCIATED FINDINGS:• Left atrial enlargement• LA/ LAA thrombus• RV dilatation and dysfunction• Pulmonary hypertension

ECHO EVALUATION OF MITRAL STENOSIS

Page 30: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

TRICUSPID STENOSIS

Page 31: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

TRICUSPID STENOSIS

• Uncommon• Almost always due to RHD• Other causes:• Congenital tricuspid atresia• RA tumor/mass (myxoma,

thrombus, vegetation)• Carcinoid Syndrome

Page 32: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

A. Determine valve morphology and mobility of the leaflets

ECHO EVALUATION OF TRICUSPID STENOSIS

Page 33: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

B. Measure the valve areaTVA = 190 ÷ PHT

C. Measure the mean gradient

ECHO EVALUATION OF TRICUSPID STENOSIS

Page 34: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

ECHO EVALUATION OF TRICUSPID STENOSIS

Page 35: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

PULMONIC STENOSIS

Page 36: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

PULMONIC STENOSIS

Causes:• Congenital• Rheumatic• Carcinoid Syndrome

Page 37: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

A. Determine valve morphology and mobility of the leaflets

ECHO EVALUATION OF PULMONIC STENOSIS

Page 38: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

B. Measure the peak velocity and gradient across the valve

ECHO EVALUATION OF PULMONIC STENOSIS

Page 39: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

ECHO EVALUATION OF PULMONIC STENOSIS

Page 40: ECHOCARDIOGRAPHIC EVALUATION OF VALVULAR … · ECHO EVALUATION OF MITRAL STENOSIS. TRICUSPID STENOSIS. TRICUSPID STENOSIS • Uncommon • Almost always due to RHD • Other causes:

SUMMARY

• Echocardiography is the primary non invasive imagingtool for the assessment of valve stenosis

• Echocardiographic evaluation should includedetermination of valve morphology, measurement ofvalve area, transvalvular gradient and velocity as wellas to look for other associated abnormalities

• It is essential to combine all 2D and Doppler data ingrading the severity of stenosis and not relying only inone specific parameter.