GRID
ALSTOM SynchroPhasor SolutionsNYISO 2010 Smart Grid Forum
Jay GiriManu Parashar
December 10th, 2010
Agenda
1. Overview of ALSTOM’s SynchroPhasor Solutions
2. PMU and openPDC (openPDC)
3. Wide Area Situational Awareness (e-terravision)
− PMU Monitoring
− Oscillatory Stability Monitoring
− Online Stability Solutions (VSAT, SSAT,TSAT)
− Disturbance Detection & Location
− Islanding and Restoration
4. ALSTOM’s Current Offerings
5. Q&A Session
ALSTOM SynchroPhasor Solutions
ALSTOM’s Integrated SynchroPhasor Solution
G G
G
Wide-Area Advanced
Visualization
e-terravision
PMU Measurement-based information
(e.g. Oscillation Detection)
EMSImproved State Estimation using PMUs
e-terratransmission
1 per secondPhasor Data
Concentrator (openPDC)
Online Stability Solutions
30-60 per second
PMUs
PMUs
PMUs
ALSTOM SynchroPhasor Solutions
e-te
rravis
ion
PM
Us
in E
MS
Ap
plic
atio
ns
NE
W P
MU
-bas
ed A
pp
licat
ion
s(r
esid
e o
uts
ide
trad
itio
nal
EM
S)
Generalized Grid Security Framework
Super-PDC
New PMU
Measurement
based
Analysis
Traditional
EMS Model-based
Analysis
SCADA
& AlarmsWAMS
State
Estimator
State
Measurement
Other EMS
Applications
New
Applications
Small Signal
Stability
Oscillation
Monitoring
Transient
& Voltage
Stability
Stability
Monitoring
& Control
EMS Generalized
Security System
Grid
System- Level
ALSTOM SynchroPhasor Solutions
Agenda (cont.)
7. Specific Design and Functionality Questions – 1 hr− Scalability− Communication− Logging − Remote Configuration − Configuration Management− Standards Compliance− Security− Handling redundant data streams− Failover / Disaster Recovery− Local storage / buffering− Platform requirements− Visualization customization− Interoperability
• Design for interoperability
• Integration (APIs) with other systems (EMS/SCADA, power analysis apps, etc)
WECC - September, 2010
PMU & openPDCData Acquisition and Management
ALSTOM PMU (P847 Information)
Analog Channels
− Va, Vb ,Vc− Ia , Ib ,Ic− V1, V2,V0− I1 , I2 , I0− Frequency− Rate of Change of Frequency
Digital Channels
− Selectable − Any 8 status signals available
openPDC Backgroud
• Developed by TVA in support of the DOE sponsored NASPI initiative.
• In service at TVA (as ‘superPDC’ for Eastern Interconnection) since 2004.
• Currently collecting and storing data from over 120 PMUs across the Eastern Interconnection.
• Continually being enhanced & improved by Grid Protection Alliance (GPA), a non-profit company formed by the original openPDC developers, under contract to NERC
− Multiple releases (v1.0, v1.1, v1.2 & v1.3) this year; next release planned for Jan, 2011 (focus on security enhancements).
• Several current (and planned) openPDC evaluations underway at various ISOs, TOs including:
− TVA – Duke Energy – ISO-NE− PJM – Oklahoma Gas & Electric – BPA− MISO – Pacific Gas & Electric− FPL – American Electric Power− WECC – Dominion Power
ALSTOM SynchroPhasor Solutions
Extensible functionality through the notion of ‘Input’, ‘Action’, & ‘Output’
Adapters.
• Input Adapters: process incoming data into a generic format.
• Action Adapters: perform processing functions such as sorting the input data or performing calculations (e.g. MW and MVAR, Event Detection), then transmit the results.
• Output Adapters: store time sorted data in Historians.
Modular Architecture (Adapter Layers)
Source: http://openpdc.codeplex.com/wikipage?title=Overview&referringTitle=Documentation
New InputProtocol
New Processing
New OutputProtocol
Database
ALSTOM SynchroPhasor Solutions
Supported Input and Output Formats
• INPUT FORMATS− IEEE C37.118-2005 & Draft 6− BPA PDC Stream− SEL Fast Messaging− IEEE 1344-1995− Virginia Tech FNET− Macrodyne− IEC 61850-90-5 (Future)
• OUTPUT FORMATS− IEEE C37.118-2005 (optional auto-publish configuration frame)− BPA PDC Stream− ALSTOM Inter-Site Data (ISD) protocol for integration with EMS applications− Text based export− OPC (Future)
• COMMUNICATION STANDARDS− TCP IPv4 & IPv6− UDP Unicast / Multicast IPv4 & IPv6− Serial (Input Only)
OpenPDC Configuration
Management UI
Historian Options and Interfaces
• A historian local to the openPDC hardware is standard.
(includes Binary Files with automatic purging of outdated data & web based
retrieval mechanism).
• Interfaces to external historians through Output Adapters:
− Relational Systems (e.g., SQL Server, MySQL, Oracle)− CSV exports− OSIsoft PI (via C37.118 Protocol)− Open Historian using open source Hadoop storage− Text based, CSV− COMTRADE
• Interfaces for retrieving latest or historical data and metadata (REST Services or Subscription API)
Agenda (cont.)
7. Specific Design and Functionality Questions – 1 hr− Scalability− Communication− Logging − Remote Configuration − Configuration Management− Standards Compliance− Security− Handling redundant data streams− Failover / Disaster Recovery− Local storage / buffering− Platform requirements− Visualization customization− Interoperability
• Design for interoperability
• Integration (APIs) with other systems (EMS/SCADA, power analysis apps, etc)
WECC - September, 2010
e-terravision Advanced Visualization Framework for the
Electric Power Grid
Wide Area Situational Awareness Visualization
Grid Security Monitor
Wide Area Security
Situation AwarenessWide Area Visualization
Steady State
Security
DynamicSecurity
UI Navigation
WAMSAlerts
UI Navigation
PMU angles &
Oscillation
Monitoring
EMS RT
Network
Analysis
Small signal
Voltage
Transient
Local
UI &
Storage
PMU-based Apps Network Model-based Apps
Correlation
Non-operational
Data
Condition monitoringWeather information
Power system Grid
What is e-terravision?
• e-terravision is a decision support system for control centers.
− By providing actionable information for faster and more confident real-time decision making.
• Offers a unified view across the entire grid interconnection.
− Overview and regional schematic displays when needed− Efficient navigation through data to get to “information”
• Mitigate operational risks, ensure system reliability.
• Built for high availability
• Designed in collaboration with major utilities:
− AEP, TVA, Entergy, First Energy, etc…
• Certified by Situation Awareness (SA) industry experts
− Mica Endsley, SA Technologies, Marietta GA
NYISO - August, 2010
Query: station voltages
Flyout: SCADA 1-lines
Power flow animation
Wide Area Situational Awareness Visualization (e-terravision)
Dynamic Dashboard, Trends, Pie Charts
Contour: area Voltage
Trend Charts
e-terravision Architecture
RT Data Sources/Providers
•PDC/PMU data
•RT SCADA & topology
•Steady State Network Analysis (CA/SE)
•Transient Stability Analysis
•Weather Data, Fires, Lightning…
•RTDMS, Space-Time-Insight, etc
Network Model Import
e-terravision
Viewer
(Workstations)
e-terravision Viewer
(Wallboard)
e-terravision Viewer
(Corporate Office, TO’s)
Citrix Servers
PDC DS1 DSn
e-terravision @
TOs
PMU
Measurements
C3
7.1
18
CIM
/XM
L
PS
SE
Non-Operational Data
KM
L F
ile
s
e-terravision Functionalities & Data Requirements
ALSTOM SynchroPhasor Solutions
DATA SOURCE P
MU
AN
GL
E&
VO
LTA
GE
PR
OF
ILE
S
AN
GL
ED
IFF
ER
EN
CE
PA
IRS
OS
CIL
LA
TO
RY
STA
BIL
ITY
MO
NIT
OR
ING
(OS
M)
DIS
TU
RB
AN
CE
AL
AR
MS
ISL
AN
DD
ET
EC
TIO
N
RE
ST
OR
AT
ION
RE
AL-T
IME
ME
AS
UR
EM
EN
TS
SC
AD
A A
LE
RT
S&
AL
AR
MS
STA
TE
ES
TIM
AT
ION
(SE
)
CO
NT
ING
EN
CY
AN
ALY
SIS
(CA
)
VO
LTA
GE
STA
BIL
ITY
AS
SE
SS
ME
NT
(SS
AT
)
SM
AL
LS
IGN
AL
STA
BIL
ITY
AS
SE
SS
ME
NT
(SS
AT
)
TR
AN
SIE
NT
STA
BIL
ITY
AS
SE
SS
ME
NT
(TS
AT
)
WE
AT
HE
R
LIG
HT
EN
ING
PMU Data(IEEE C37.118) × × × × ×SCADA Data(ICCP) × × × × × × ×Network Data(PSSE or CIM/XML)
× × × × × × × × × ×
Dynamic Data(PSSE) × × × × × × × × × × × ×Non-Electric Data(KML Files)
× × × × × × × × × × × × × ×
PMU Only SCADA Network Dynamic Other
PMU Information in e-terravision
Monitor ‘angular separation’ as an indicator of increased grid stress due to:
Monitor ‘Angle Separation’ between source & sink
Phase angular spread across power system
ALSTOM SynchroPhasor Solutions
Identify low voltage areas
Oscillatory Stability Monitoring (OSM)Uses PMU data at the 10-60 sample/sec rate
G G
G
(30-60 per second)
Oscillatory Mode Frequencyf
Oscillatory Mode Damping
Oscillatory Mode Shape
(i.e. Amplitude & Phasing)
Real-time Measurements
from the Power System
A
PMU measurement-based approach.
Process the most recent PMU data
to characterize oscillatory dynamics:
– Frequency of oscillatory dynamics
– Oscillation decay rate or damping
– Participation of units in oscillations (Mode Shape)
PMU datacapture
PM
U-b
ased
osc
illa
tory
stab
ility
an
alys
is
ALSTOM SynchroPhasor Solutions
Small Signal Oscillatory Stability MonitoringModes shapes, amplitudes, damping, frequency, etc
Real-time alerts on poorly damped oscillations
Identify regions where inter-area oscillations are observable
Track oscillatory
stability in real-time.
ALSTOM SynchroPhasor Solutions
Small Signal Oscillatory Stability Monitoring DisplaysUses PMU data at the 10-60 sample/sec rate
Mode Frequency &
Damping Trends
Mode Shape
Information
Mode Energy Trends
Power SpectrumQuickly identify prominent
oscillatory modes.
Oscillatory Mode TrendingTrack mode damping levels
over time.
Higher energy at mode frequency
excited by event on the grid
Launch OSM Analyst displays directly from e-terravision.
Agenda (cont.)
7. Specific Design and Functionality Questions – 1 hr− Scalability− Communication− Logging − Remote Configuration − Configuration Management− Standards Compliance− Security− Handling redundant data streams− Failover / Disaster Recovery− Local storage / buffering− Platform requirements− Visualization customization− Interoperability
• Design for interoperability
• Integration (APIs) with other systems (EMS/SCADA, power analysis apps, etc)
WECC - September, 2010
Online Stability Solutions (OSS)
Online Stability Solutions (OSS)
An integrated measurement-based and model-based stability assessment
application that runs in real time.
Stability assessment visualization within e-terravision.
ALSTOM SynchroPhasor Solutions
PMU measurement-based methods
monitor grid stability in real-time: – Track current damping levels.
– Detect & alarm on dangerous oscillations
& sudden events.
PREDICT & MITIGATE
EDGE
MONITOR
OPERATING POINT
Model-based techniques (SSAT, TSAT, VSAT)
provide the predictive component (i.e. ‘what-if’ analysis)
– Available MW transfer capability (‘distance’ to the edge)
– Assess impact of critical contingencies. (e.g. change in damping levels)
– Recommend controls based on sensitivity information.
Voltage Security Assessment Voltage Contours, MW Margins, Weak Elements, Remedial Actions
Identify weak elements (i.e. regions most prone
to voltage instability)
MW Transfer Margins
Control Recommendations
ALSTOM SynchroPhasor Solutions
Regional Reactive Reserves Where are the Vars ?
Select region of interest to identify available VAR resources
Detailed summary of existingresources within chosen region
ALSTOM SynchroPhasor Solutions
Use PMUs and SCADA data to triangulate
precisely locate the origin of the disturbance
A sudden disturbance causes a traveling wave that can be detected by PMU data across the grid:
Source: VirginiaTech FNET
Disturbance Location
Disturbance Location
ALSTOM SynchroPhasor Solutions
Disturbance alerts/alarms within e-terravision
e-terravision
Islanding Detection and Restoration
• Use the high resolution PMU data to detect an islanding situation
based on the fast separation of phase angles.
• Determine the coherent groups of generators (those swinging in
unison).
• Identify (1) individual islands, (2) associated points of separation,
and (3) available resources within the island.
• Assist with the re-synchronization and restoration process.
Coherent Groups
Agenda (cont.)
7. Specific Design and Functionality Questions – 1 hr− Scalability− Communication− Logging − Remote Configuration − Configuration Management− Standards Compliance− Security− Handling redundant data streams− Failover / Disaster Recovery− Local storage / buffering− Platform requirements− Visualization customization− Interoperability
• Design for interoperability
• Integration (APIs) with other systems (EMS/SCADA, power analysis apps, etc)
WECC - September, 2010
ALSTOM’s Current Offerings
Deployment Options:
e-terravision Server
(redundant pair)
openPDC (C37.118)
FUNCTIONALITY• PMU Angles / Angle Difference Pairs
•Oscillatory Stability Monitoring (OSM)
•Disturbance Alarms
•Island Detection & Restoration (FUTURE)
•State Estimator (SE)
•Contingency Analysis (CA)
•Weather & Lightening Data
•Voltage Stability Assessment (VSAT)
•Small-Signal Stability Assessment (SSAT)
•Transient Stability Assessment (TSAT)
e-terravision Viewer
Non-Alstom EMS
•CIM/XML or PSSE file
•Contingency Analysis .csv file
KML
file
DSA Tools
-VSAT
-SSAT
-TSAT
PMU Data
+ SESnapshot
+ KML Files
+ DSA Tools
ALSTOM’s Current Offering
openPDC Integration Services
− openPDC ISD interface to SCADA
Improved State Estimation using Voltage and Current PMU data
Wide Area Situational Awareness Visualization (WASA)
− Monitoring angle differences for instability− Faster detection & alarming of unexpected events− Identifying low voltage areas
• Identifying available, relevant voltage support sources − User-created, on-the-fly, dynamic dashboards
• For current area of interest
• Combine SE & SCADA information with PMU information
• Trending & monitoring of specific grid conditions
Online Stability Solutions (OSS) integrated with visualization platform:
− VSAT /SSAT/TSAT integration with Visualization platform− Oscillatory stability monitoring (OSM), detection & corrective control recommendations
PMU Placement – Optimal Siting Studies
ALSTOM SynchroPhasor Solutions
openPDC Webinar - September 2010
Agenda (cont.)
7. Specific Design and Functionality Questions – 1 hr− Scalability− Communication− Logging − Remote Configuration − Configuration Management− Standards Compliance− Security− Handling redundant data streams− Failover / Disaster Recovery− Local storage / buffering− Platform requirements− Visualization customization− Interoperability
• Design for interoperability
• Integration (APIs) with other systems (EMS/SCADA, power analysis apps, etc)
WECC - September, 2010
Thank You
Questions/Comments ?