Transcript of E ion Presentation PDF
-
8/3/2019 E ion Presentation PDF
1/22
WATER ENVIRO
ENGINEERSPresents
E-Ionization
Water & Waste WaterTreatment Systems
-
8/3/2019 E ion Presentation PDF
2/22
GO GREEN . GO CLEAN
-
8/3/2019 E ion Presentation PDF
3/22
GO GREEN WITH
E-IONIZATION PROCESS
DOES NOT GENERATE GREEN HOUSE GASES
DOES NOT DEPLETE ATMOSPHERIC OXYGEN
DOES NOT EMIT CARBON
CONSERVES WATER
CONSERVES ENERGY
CONSERVES CHEMICALS
-
8/3/2019 E ion Presentation PDF
4/22
E-Ionization Process of
Water Treatment isChemical Free
Non Biological
-
8/3/2019 E ion Presentation PDF
5/22
E-Ionization Process
E-Ionization Is A Technique Involving The Passage Of
Electricity Through Water Or Effluent To Be Treated.
The Electric Current Destabilizes Dissolved And Colloidal
Particles And Alters The Charge On Suspended Matter
Permitting Their Removal.
-
8/3/2019 E ion Presentation PDF
6/22
WATER QUALITY
-
8/3/2019 E ion Presentation PDF
7/22
Does not generate green house gases
Does not deplete atmospheric oxygen
Emits low carbon
Chemical free, non biological
Accelerated start up
Packaged modular in construction
Noiseless operation Compact plant with small foot print
Environmental, operator and user friendly
Custom designed
Easily expandable
System designed for continuous or batch operation Hybrid electrode connection
Can be retrofitted in the existing facility
Special Features of the E-Ionization Process
-
8/3/2019 E ion Presentation PDF
8/22
Functions Of E-Ionization Process
Removes :
Organics
Suspended Solids
Turbidity
Algae
Odor
Fats, Oil And Grease
Heavy Metals Colour &
Disinfects Water
-
8/3/2019 E ion Presentation PDF
9/22
Raw Water
Swimming Pool
Sewage Water
Cooling Tower &
Effluent (wide ranging waste streams)
Applications Of E-Ionization Process for Water Treatment
-
8/3/2019 E ion Presentation PDF
10/22
Advantages Of E-Ionization Processes
1. Does not generate green house gases
2. Does not deplete atmospheric oxygen
3. Conserves water, conserves energy, conserves chemicals and conserves
space
4. Eliminates Procurement, Transportation, Storage, Preparation And Use
Of Hazardous And Expensive Chemicals making it operator friendly
5. High Contaminant Removal
6. Reduces Dependence On External Source For Water Supply In Pursuit
Of Self Reliance
7. Savings In Water Cost As Treated Water Is Less Expensive Than
Cost Of Bought Out Water
8. Helps Conserve Valuable Water Resource By Recycling Treated
Water Throughout The Year Unlike Rain Water Harvesting which Is
Seasonal
-
8/3/2019 E ion Presentation PDF
11/22
Sewage Water Treatment
-
8/3/2019 E ion Presentation PDF
12/22
Comparison for Sewage Water Treatment - I
E-Ionization Process Conventional Biological Activated
Sludge Process
Does not generate green house gases
Does not deplete atmospheric
oxygen
Emits low carbon
Non Chemical, Non Biological
Process
Does not Need Aeration
No Need to maintain biomass, pH,
temperature
Accelerated start up
Conserves more water due to better
quality treatment
Generates green house gases
Depletes atmospheric oxygen
Microbiological Process
Emits carbon
Biological needs chemicals for
disinfection
Needs Aeration with Aeration
Machinery
Needs to maintain biomass, pH,
temperature
Prolonged start up period
Conserves less water due to poor
quality treatment
-
8/3/2019 E ion Presentation PDF
13/22
Comparison for Sewage Water Treatment - II
E-Ionization Process Conventional Biological Activated
Sludge Process
Shock Load can be Easily Tackled
Independent of Toxicity
Noiseless
Generates Less Sludge with Better
Dewatering
Compact Plant with Small Foot Print
Shock Load cannot be Tackled
Toxicity destroys Microbes,
Restoration takes Time
Noisy because of Aerators
Associated Drive
Generates More Sludge with Lower
Dewatering
Voluminous with Large Foot Print
-
8/3/2019 E ion Presentation PDF
14/22
-
8/3/2019 E ion Presentation PDF
15/22
-
8/3/2019 E ion Presentation PDF
16/22
Disadvantages Of Chemicals - II
Chemical Treatment removes one type of Contaminant and introducesanother. Alum and PAC increases acidity and Total Dissolved Solids. To
increase the Efficiency of Coagulation and to Neutralize the increase in
Acidity, Alkaline Chemicals are needed, which again contributes to increase
in Total Dissolved Solids and thus increases Chemical Constituents in water
that we drink. These Chemicals have only 5% of Active Coagulants in them,rest contributes to increase in Acidity and Total Dissolved Solids.
Elemental chlorine is hazardous not only in transportation, storage and
handling, but in its elemental form generates disinfecting by products which
are generally known as DBPs.
Chemical requirement assessment needs skill manpower and analytical
laboratory. In addition these chemicals have to be procured, multi transported
and stored in large quantities. Chemical handling, preparation equipments and
Dosers are needed till it reaches its destination.
-
8/3/2019 E ion Presentation PDF
17/22
FLOW SCHEME
RAW
WATER
TREATED
WATER
I NFLUENT
ELECTROCELL
-
8/3/2019 E ion Presentation PDF
18/22
Space required
Biological
E-Ionization
-
8/3/2019 E ion Presentation PDF
19/22
Residence & reaction time
Hours
12
Hrs
1 Hr
Biological E-Ionization
-
8/3/2019 E ion Presentation PDF
20/22
Start up time
Biological E-Ionization
One month
Time
One hour
-
8/3/2019 E ion Presentation PDF
21/22
COMPACT SEWAGE TREATMENT PLANT
CAPACITY100,000LTRS/DAY
Electro cell
-
8/3/2019 E ion Presentation PDF
22/22
COMPANY ADDRESS
WATER ENVIRO ENGINEERS.
PH.NO. (O) 24791760,28335255,
MOBILE: 9969966738/ 09376212396
E-MAIL:[email protected]
Factory : Block no.75,Sokhda mukutnagarroad,Savli, Tal : Manjusar , Vadodara ,
Gujarat.
mailto:[email protected]:[email protected]