E ion Presentation PDF

download E ion Presentation PDF

of 22

Transcript of E ion Presentation PDF

  • 8/3/2019 E ion Presentation PDF

    1/22

    WATER ENVIRO

    ENGINEERSPresents

    E-Ionization

    Water & Waste WaterTreatment Systems

  • 8/3/2019 E ion Presentation PDF

    2/22

    GO GREEN . GO CLEAN

  • 8/3/2019 E ion Presentation PDF

    3/22

    GO GREEN WITH

    E-IONIZATION PROCESS

    DOES NOT GENERATE GREEN HOUSE GASES

    DOES NOT DEPLETE ATMOSPHERIC OXYGEN

    DOES NOT EMIT CARBON

    CONSERVES WATER

    CONSERVES ENERGY

    CONSERVES CHEMICALS

  • 8/3/2019 E ion Presentation PDF

    4/22

    E-Ionization Process of

    Water Treatment isChemical Free

    Non Biological

  • 8/3/2019 E ion Presentation PDF

    5/22

    E-Ionization Process

    E-Ionization Is A Technique Involving The Passage Of

    Electricity Through Water Or Effluent To Be Treated.

    The Electric Current Destabilizes Dissolved And Colloidal

    Particles And Alters The Charge On Suspended Matter

    Permitting Their Removal.

  • 8/3/2019 E ion Presentation PDF

    6/22

    WATER QUALITY

  • 8/3/2019 E ion Presentation PDF

    7/22

    Does not generate green house gases

    Does not deplete atmospheric oxygen

    Emits low carbon

    Chemical free, non biological

    Accelerated start up

    Packaged modular in construction

    Noiseless operation Compact plant with small foot print

    Environmental, operator and user friendly

    Custom designed

    Easily expandable

    System designed for continuous or batch operation Hybrid electrode connection

    Can be retrofitted in the existing facility

    Special Features of the E-Ionization Process

  • 8/3/2019 E ion Presentation PDF

    8/22

    Functions Of E-Ionization Process

    Removes :

    Organics

    Suspended Solids

    Turbidity

    Algae

    Odor

    Fats, Oil And Grease

    Heavy Metals Colour &

    Disinfects Water

  • 8/3/2019 E ion Presentation PDF

    9/22

    Raw Water

    Swimming Pool

    Sewage Water

    Cooling Tower &

    Effluent (wide ranging waste streams)

    Applications Of E-Ionization Process for Water Treatment

  • 8/3/2019 E ion Presentation PDF

    10/22

    Advantages Of E-Ionization Processes

    1. Does not generate green house gases

    2. Does not deplete atmospheric oxygen

    3. Conserves water, conserves energy, conserves chemicals and conserves

    space

    4. Eliminates Procurement, Transportation, Storage, Preparation And Use

    Of Hazardous And Expensive Chemicals making it operator friendly

    5. High Contaminant Removal

    6. Reduces Dependence On External Source For Water Supply In Pursuit

    Of Self Reliance

    7. Savings In Water Cost As Treated Water Is Less Expensive Than

    Cost Of Bought Out Water

    8. Helps Conserve Valuable Water Resource By Recycling Treated

    Water Throughout The Year Unlike Rain Water Harvesting which Is

    Seasonal

  • 8/3/2019 E ion Presentation PDF

    11/22

    Sewage Water Treatment

  • 8/3/2019 E ion Presentation PDF

    12/22

    Comparison for Sewage Water Treatment - I

    E-Ionization Process Conventional Biological Activated

    Sludge Process

    Does not generate green house gases

    Does not deplete atmospheric

    oxygen

    Emits low carbon

    Non Chemical, Non Biological

    Process

    Does not Need Aeration

    No Need to maintain biomass, pH,

    temperature

    Accelerated start up

    Conserves more water due to better

    quality treatment

    Generates green house gases

    Depletes atmospheric oxygen

    Microbiological Process

    Emits carbon

    Biological needs chemicals for

    disinfection

    Needs Aeration with Aeration

    Machinery

    Needs to maintain biomass, pH,

    temperature

    Prolonged start up period

    Conserves less water due to poor

    quality treatment

  • 8/3/2019 E ion Presentation PDF

    13/22

    Comparison for Sewage Water Treatment - II

    E-Ionization Process Conventional Biological Activated

    Sludge Process

    Shock Load can be Easily Tackled

    Independent of Toxicity

    Noiseless

    Generates Less Sludge with Better

    Dewatering

    Compact Plant with Small Foot Print

    Shock Load cannot be Tackled

    Toxicity destroys Microbes,

    Restoration takes Time

    Noisy because of Aerators

    Associated Drive

    Generates More Sludge with Lower

    Dewatering

    Voluminous with Large Foot Print

  • 8/3/2019 E ion Presentation PDF

    14/22

  • 8/3/2019 E ion Presentation PDF

    15/22

  • 8/3/2019 E ion Presentation PDF

    16/22

    Disadvantages Of Chemicals - II

    Chemical Treatment removes one type of Contaminant and introducesanother. Alum and PAC increases acidity and Total Dissolved Solids. To

    increase the Efficiency of Coagulation and to Neutralize the increase in

    Acidity, Alkaline Chemicals are needed, which again contributes to increase

    in Total Dissolved Solids and thus increases Chemical Constituents in water

    that we drink. These Chemicals have only 5% of Active Coagulants in them,rest contributes to increase in Acidity and Total Dissolved Solids.

    Elemental chlorine is hazardous not only in transportation, storage and

    handling, but in its elemental form generates disinfecting by products which

    are generally known as DBPs.

    Chemical requirement assessment needs skill manpower and analytical

    laboratory. In addition these chemicals have to be procured, multi transported

    and stored in large quantities. Chemical handling, preparation equipments and

    Dosers are needed till it reaches its destination.

  • 8/3/2019 E ion Presentation PDF

    17/22

    FLOW SCHEME

    RAW

    WATER

    TREATED

    WATER

    I NFLUENT

    ELECTROCELL

  • 8/3/2019 E ion Presentation PDF

    18/22

    Space required

    Biological

    E-Ionization

  • 8/3/2019 E ion Presentation PDF

    19/22

    Residence & reaction time

    Hours

    12

    Hrs

    1 Hr

    Biological E-Ionization

  • 8/3/2019 E ion Presentation PDF

    20/22

    Start up time

    Biological E-Ionization

    One month

    Time

    One hour

  • 8/3/2019 E ion Presentation PDF

    21/22

    COMPACT SEWAGE TREATMENT PLANT

    CAPACITY100,000LTRS/DAY

    Electro cell

  • 8/3/2019 E ion Presentation PDF

    22/22

    COMPANY ADDRESS

    WATER ENVIRO ENGINEERS.

    PH.NO. (O) 24791760,28335255,

    MOBILE: 9969966738/ 09376212396

    E-MAIL:[email protected]

    Factory : Block no.75,Sokhda mukutnagarroad,Savli, Tal : Manjusar , Vadodara ,

    Gujarat.

    mailto:[email protected]:[email protected]