E hD EK X KEFrozen Bun Alt. Existing Dumpster location (dumpsters accessed from alley) 11 AS3.1 9...

8
2810 Duniven Circle Amarillo, Texas 806/358-7069 ADDENDUM NO. ONE DATE: April 3, 2020 FROM: Lavin Architects TO: Plan Holders of Record PROJECT: Toot’ N Totum 2401 South Main St. Perryton, Texas 79070 This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents dated March 17, 2020. Work not specifically deleted, modified, changed or altered by the Addendum should remain in effect as part of the Contract Documents. Acknowledge receipt of this Addendum in the space provided on the Bid Form. Failure to do so may subject Bidder to disqualification. ON THE DRAWINGS: Sheet AS1.1 1. Note 15 & Note 16/AS1.1: Wendy’s to supply and install site signage as noted. See attached sheet. Sheet AS3.1 1. Sign Elevations 9, 10 and 11/AS3.1: Wendy’s to supply and install site signage as noted. See attached sheet. Sheet A1.1 1. Note 13: owner to remove and salvage kitchen equipment as noted. See attached sheet. 2. Note 14: owner to remove and reinstall existing awning as noted. See attached Sheet. Sheet A1.2 1. Note 5: Wendy’s to provide and install stainless steel panels as noted. See attached sheet. 2. Note 12: Wendy’s to provide evaporator, insulated ramp, etc. as noted. See attached sheet. Plumbing 1. See attached sheets. Electrical 1. See attached sheets. END OF ADDENDUM NO. 1

Transcript of E hD EK X KEFrozen Bun Alt. Existing Dumpster location (dumpsters accessed from alley) 11 AS3.1 9...

Page 1: E hD EK X KEFrozen Bun Alt. Existing Dumpster location (dumpsters accessed from alley) 11 AS3.1 9 AS3.1 10 AS3.1 EX. BOLLARD @ DUW TO REMAIN PICK-UP WINDOW R R CONVERSION REMODEL E2000

2810 Duniven Circle Amarillo, Texas 806/358-7069

ADDENDUM NO. ONE

DATE: April 3, 2020 FROM: Lavin Architects TO: Plan Holders of Record PROJECT: Toot’ N Totum

2401 South Main St. Perryton, Texas 79070

This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents dated March 17, 2020. Work not specifically deleted, modified, changed or altered by the Addendum should remain in effect as part of the Contract Documents. Acknowledge receipt of this Addendum in the space provided on the Bid Form. Failure to do so may subject Bidder to disqualification. ON THE DRAWINGS: Sheet AS1.1 1. Note 15 & Note 16/AS1.1: Wendy’s to supply and install site signage as noted. See attached sheet. Sheet AS3.1 1. Sign Elevations 9, 10 and 11/AS3.1: Wendy’s to supply and install site signage as noted. See

attached sheet. Sheet A1.1 1. Note 13: owner to remove and salvage kitchen equipment as noted. See attached sheet. 2. Note 14: owner to remove and reinstall existing awning as noted. See attached Sheet. Sheet A1.2 1. Note 5: Wendy’s to provide and install stainless steel panels as noted. See attached sheet. 2. Note 12: Wendy’s to provide evaporator, insulated ramp, etc. as noted. See attached sheet. Plumbing 1. See attached sheets. Electrical 1. See attached sheets. END OF ADDENDUM NO. 1

Page 2: E hD EK X KEFrozen Bun Alt. Existing Dumpster location (dumpsters accessed from alley) 11 AS3.1 9 AS3.1 10 AS3.1 EX. BOLLARD @ DUW TO REMAIN PICK-UP WINDOW R R CONVERSION REMODEL E2000

Toot' N Totum

US Hwy 83 / Main Street

2401 SOUTH MAIN STREET

Loop

143

/ 24

th A

venu

e

8 PumpsGas Canopy

6 LanesFuel Canopy

Stor.

Future CNG

N. 00° 33' 16" W. - 290.00'99.72'N. 00° 33' 16" W.

N. 8

9° 3

3' 4

6" E

. - 2

00.0

4'

N. 8

9° 3

3' 4

6" E

.

N. 4

4° 2

6' 2

4" E

.14

.13'

N. 47° 52' 39" E.

60.15'

S. 8

9° 3

7' 5

5" W

. - 3

00.2

3'

N. 00° 33' 16" W. - 579.29'

S. 00° 33' 51" E. - 629.65'

45.1

1'

Existing Alley

14 Spaces

10 S

pace

s

8 S

pace

s

New XFMR, Ref. Elec.

Toot' N Totum2401 SOUTH MAIN STREET

14 Spaces

8 S

pace

s

Toot' N Totum2401 SOUTH MAIN STREET

14 Spaces

8 S

pace

s

REGIS

TERED ARCHI TEC

T

STATE

OF TE

XAS

3/17/2020

SEAL

DESCRIPTIONDATEREV.

ISSUE DATE: 3/17/2020

PROJECT NUMBER: 2019-16

DRAWN BY:

CHECKED BY:

SHEET NAME

SHEET NUMBER

SITE NUMBER:

BASE MDL:

OWNER:

BASE VERSION:

DRAWING RELEASE

PROJECT YEAR:

ASSET TYPE:

CLASSIFICATION:

UPGRADE CLASSIFICATION:

FURNITURE PACKAGE:

2401

SO

UTH

MA

IN S

TRE

ET

PE

RR

YTO

N, T

EX

AS

, 790

70

PROJECT TYPE:

12245

REMODEL E2000

FRANCHISEE

CONVERSION

TOOT N TOTUM

2019 FALL

CONVERSION

2020

UM BRIGHT

SPRING 2020

CONVERSIONREMODEL E2000

AS1.1ARCHITECTURAL SITE PLAN

01OVERALL SITE PLANSCALE: 1" = 40'-0" NORTH

02ENLARGED PARTIAL DEMOLITION PLANSCALE: 1/16" = 1'-0" NORTH 03ENLARGED PARTIAL SITE PLAN

SCALE: 1/16" = 1'-0" NORTH

04PIPE BOLLARDSCALE: 1/2"=1'-0"

AutoCAD SHX Text
PICK-UP WINDOW
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
CONVERSION REMODEL E2000
AutoCAD SHX Text
242 SF Walk-in - 1,992 SF TOTAL
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
42 SEATS - 471 SF
AutoCAD SHX Text
F
AutoCAD SHX Text
C
AutoCAD SHX Text
F
AutoCAD SHX Text
PUW
AutoCAD SHX Text
Area
AutoCAD SHX Text
Landscape
AutoCAD SHX Text
Area
AutoCAD SHX Text
Landscape
AutoCAD SHX Text
Frozen Bun Alt.
AutoCAD SHX Text
Existing Dumpster location (dumpsters accessed from alley)
AutoCAD SHX Text
11
AutoCAD SHX Text
AS3.1
AutoCAD SHX Text
9
AutoCAD SHX Text
AS3.1
AutoCAD SHX Text
10
AutoCAD SHX Text
AS3.1
AutoCAD SHX Text
EX. BOLLARD @ DUW TO REMAIN
AutoCAD SHX Text
PICK-UP WINDOW
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
CONVERSION REMODEL E2000
AutoCAD SHX Text
242 SF Walk-in - 1,992 SF TOTAL
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
42 SEATS - 471 SF
AutoCAD SHX Text
F
AutoCAD SHX Text
C
AutoCAD SHX Text
F
AutoCAD SHX Text
PUW
AutoCAD SHX Text
Frozen Bun Alt.
AutoCAD SHX Text
Existing Dumpster location (dumpsters accessed from alley)
AutoCAD SHX Text
Site Plan Notes:
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
6
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
REMOVE EXISTING DRIVE UP SPEAKER AND STOP SIGN. PATCH CONCRETE TO MATCH EXISTING ADJACENT CONCRETE CONSTRUCTION. REMOVE AN AREA OF CONC. WALK (TO EX. JOINTS) AS REQ'D. TO INSTALL WENDY'S DISPLAY, MENU BOARD, ETC. REMOVE EXISTING "U" SHAPED BALLARDS SHOWN DASHED. PREPARE FOR NEW CONSTRUCTION. REMOVE EXISTING CLEARANCE BAR AND BOLLARD. PATCH CONCRETE TO MATCH EXISTING ADJACENT CONCRETE CONSTRUCTION. NEW CANOPY PROTECTION BAR AND FOUNDATION. SEE DETAIL SHEET AS3.1. NEW MENU BOARD AND FOUNDATION. SEE DETAIL SHEET AS3.1. NEW ORDER BOARD, CANOPY AND FOUNDATION. SEE DETAIL SHEET AS3.1. NEW PRE-SELL BOARD AND FOUNDATION. SEE DETAIL SHEET AS3.1. NEW 4" THICK, 3000 PSI CONCRETE WALK W #3 BARS AT 16" O.C. ON 2\" SAND CHAIRS AND FIBERMESH AND AIR ENTRAINING ADMIXTURE OVER 2" SANDFILL. NEW 6" THICK, 4000 PSI CONCRETE PAVING W #4 BARS AT 12" BOTH WAYS O.C. ON 4\" SAND CHAIRS AND FIBERMESH AND AIR ENTRAINING ADMIXTURE. NEW PROJECT CONSTRUCTION SIGN VERIFY LOCATION WITH OWNER. EXISTING SITE STRIPING TO BE REPAINTED. NEW STRIPING TO BE PAINTED 4" WIDE. COLOR TO MATCH EXISTING. NEW 6" SINGLE PIPE BOLLARD TO BE PAINTED. COLOR TO MATCH EXISTING. SEE DETAIL 4/AS1.1. DIRECTIONAL ARROWS AND LETTERING TO BE PAINTED ON CONCRETE PAVING SEE SHEET AS3.1 FOR DETAILS. WENDY'S TO SUPPLY AND INSTALL NEW SIGN CABINET ADDED TO TOP OF EXISTING SIGN CABINET TO REMAIN. COMPLY WITH STRUCTURAL & ELECTRICAL SPECIFICATIONS. COORD. W/ OWNER. REFER TO SIGN ELEVATION. WENDY'S TO REPLACE PORTION OF EX. SIGN GRAPHICS W/ NEW WENDY'S SIGN GRAPHICS. COORD. W/ OWNER. REF. ELEV. EXISTING CONCRETE CURB AND GUTTER TO REMAIN. EXISTING ITEMS TO REMAIN. PROTECT DURING CONSTRUCTION & PATCH AREA(S) DAMAGED BY CONSTRUCTION. REMOVE AN AREA OF EX. CONC. WALK (TO EX. JOINTS) AS REQ'D. TO REMOVE EX. GREASE INTERCEPTOR & INSTALL NEW GREASE INTERCEPTOR. PATCH CONC. TO MATCH EX. REFER TO PLUMBING. SAWCUT & REMOVE AN AREA OF EX. CONC. DRIVE AS REQ'D. TO INSTALL NEW DETECTOR LOOP. PATCH CONC. TO MATCH EX. REFER TO 07/AS3.1 & ELECTRICAL.
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
2810 DUNIVEN CIRCLE, SUITE 100.
AutoCAD SHX Text
LAVIN ASSOCIATES, INC.
AutoCAD SHX Text
AMARILLO, TEXAS (806) 358-7069
AutoCAD SHX Text
tion to the architect.
AutoCAD SHX Text
C
AutoCAD SHX Text
These plans & accom-
AutoCAD SHX Text
panying specifications
AutoCAD SHX Text
shall remain the proper-
AutoCAD SHX Text
ty of the architect and
AutoCAD SHX Text
shall not be used for
AutoCAD SHX Text
the construction of any
AutoCAD SHX Text
building other than the
AutoCAD SHX Text
building specified with-
AutoCAD SHX Text
out proper compensa-
AutoCAD SHX Text
ARCHITECTURE
AutoCAD SHX Text
1/2"EXP. JOINT W/ FILLER
AutoCAD SHX Text
18" DIA. 3000 PSI CONC. PIER
AutoCAD SHX Text
6" O.D. STEEL PIPE - FILL W/ CONC. - PAINT AS SPEC.
AutoCAD SHX Text
ROUNDED CONC. WASH PAINT AS SPEC.
AutoCAD SHX Text
1
AutoCAD SHX Text
ADDENDUM #1: 4/3/2020
Page 3: E hD EK X KEFrozen Bun Alt. Existing Dumpster location (dumpsters accessed from alley) 11 AS3.1 9 AS3.1 10 AS3.1 EX. BOLLARD @ DUW TO REMAIN PICK-UP WINDOW R R CONVERSION REMODEL E2000

01CANOPY FOOTING DETAILSCALE: 1-1/2"=1'-0"

02PRE-SELL BOARD DETAILSCALE: 3/4"=1'-0"

05CANOPY FOOTING SECTIONSCALE: 3/4"=1'-0"

06MENU BOARD FOUNDATION DETAILSCALE: N.T.S.

03ORDER STATION CANOPY SCALE: 1/2"=1'-0"

04CANOPY PROTECTION BARSCALE: 1/2"=1'-0"

07PARTIAL PLAN VIEWSCALE: 3/8"=1'-0"

08PAVEMENT MARKER DETAILSCALE: 1/2"=1'-0"

REGIS

TERED ARCHI TEC

T

STATE

OF TE

XAS

3/17/2020

SEAL

DESCRIPTIONDATEREV.

ISSUE DATE: 3/17/2020

PROJECT NUMBER: 2019-16

DRAWN BY:

CHECKED BY:

SHEET NAME

SHEET NUMBER

SITE NUMBER:

BASE MDL:

OWNER:

BASE VERSION:

DRAWING RELEASE

PROJECT YEAR:

ASSET TYPE:

CLASSIFICATION:

UPGRADE CLASSIFICATION:

FURNITURE PACKAGE:

2401

SO

UTH

MA

IN S

TRE

ET

PE

RR

YTO

N, T

EX

AS

, 790

70

PROJECT TYPE:

12245

REMODEL E2000

FRANCHISEE

CONVERSION

TOOT N TOTUM

2019 FALL

CONVERSION

2020

UM BRIGHT

SPRING 2020

CONVERSIONREMODEL E2000

AS3.1SINGLE LANE DRIVE-THRUORDER STATION DETAILS

XXX

XXX

AutoCAD SHX Text
NOTE: ENSURE CONDUIT STUB-UPS ARE INSIDE OF STEEL TUBE, AND OPEN AREA OF PEDESTAL
AutoCAD SHX Text
2 -1" CONDUITS (AUDIO AND DATA), EXTEND FROM EXTERIOR BUILDING WALL (SEE ELECTRICAL PLAN)
AutoCAD SHX Text
BASE PLATE AND STEEL TUBE SUPPORT FOR CANOPY
AutoCAD SHX Text
1" CONDUIT - SEE SHEET E2.2
AutoCAD SHX Text
FOUNDATION, SEE CANOPY AND FOUNDATION DETAIL AND STRUCTURAL
AutoCAD SHX Text
1" CONDUIT FOR ORDER CONFIRMATION (I.G.), SEE SHEET E4.2
AutoCAD SHX Text
4 1/2"x11" OPEN AREA IN BOTTOM OF PEDESTAL
AutoCAD SHX Text
1" CONDUIT FOR 1 - EXTEND THROUGH CURB @ 2" BELOW PAVEMENT FOR VEHICLE DETECTOR LOOP
AutoCAD SHX Text
FACE OF CURB
AutoCAD SHX Text
SEE SITE PLAN FOR LOCATION
AutoCAD SHX Text
10% SLOPE, TYP
AutoCAD SHX Text
BASE PLATE BY VENDOR
AutoCAD SHX Text
PRE-SALE BOARD BY VENDOR
AutoCAD SHX Text
MOUNTING BRACKET AND POSTS BY VENDOR
AutoCAD SHX Text
ANCHOR BOLTS BY VENDOR
AutoCAD SHX Text
HOLES FOR ANCHOR BOLTS
AutoCAD SHX Text
10" X 17" BASE PLATE, BY VENDOR
AutoCAD SHX Text
10% SLOPE, TYP
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
24" DIA. CONC. PIER, REF. 04/AS3.1 FOR ADD'L. INFO.
AutoCAD SHX Text
ANCHOR BOLTS, WASHERS, NUTS AND LEVELING NUTS FURNISHED BY CANOPY VENDOR & INSTALLED BY G.C.
AutoCAD SHX Text
BASE PLATE BY CANOPY VENDOR
AutoCAD SHX Text
10% SLOPE
AutoCAD SHX Text
36" DIA. CONC. PIER BELOW
AutoCAD SHX Text
12 x 12 BASE PLATE BY CANOPY VENDOR
AutoCAD SHX Text
SLOTTED HOLES FOR ANCHOR BOLTS
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
6'-0"
AutoCAD SHX Text
C/L PIER = C/L MENU BOARD
AutoCAD SHX Text
COORD. ANCHOR ROD PROJECTION W/ MENU BOARD MFR.
AutoCAD SHX Text
COORD. ANCHOR ROD
AutoCAD SHX Text
COORD. ANCHOR ROD
AutoCAD SHX Text
BOT./CONC. PIER
AutoCAD SHX Text
T/PIER
AutoCAD SHX Text
24" DIA. CONC. PIER, REF. 04/AS3.1 FOR ADD'L. INFO.
AutoCAD SHX Text
NOTE: SEE G2.1 RESPONSIBILITY SCHEDULE FOR ADD'L. INFORMATION
AutoCAD SHX Text
SHADED AREA INDICATES EXTENT OF 10% SLOPE.
AutoCAD SHX Text
®
AutoCAD SHX Text
EXTENT OF LEVELED CONCRETE PIER TOP
AutoCAD SHX Text
36" DIA. CONC. PIER W/ 12-#7 VERT. & #3 TIES @ 12"
AutoCAD SHX Text
POWDER COATED TO MATCH STOREFRONT FINISH
AutoCAD SHX Text
PLAN VIEW
AutoCAD SHX Text
SEE BELOW
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
9'-0"
AutoCAD SHX Text
9'-0"
AutoCAD SHX Text
2.875" DIA.-.203" STEEL SUPPORT PIPE - POWDER COATED DARK BRONZE.
AutoCAD SHX Text
LEVELING NUTS AND WASHERS PROVIDED BY VENDOR
AutoCAD SHX Text
1" MAX BOTTOM OF PLATE TO CONCRETE
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
(3) 1/2" DIA STEEL PIPE TO SWING RETURN PROVIDED BY VENDOR AND INSTALLED BY GC
AutoCAD SHX Text
4" DIA STEEL PIPE TO COVER PROVIDED BY VENDOR INSTALLED BY GC
AutoCAD SHX Text
ROTATION CONNECTION-CANOPY PROTECTION BAR SHALL FREELY ROTATE AND PIVOT BACK TO ORIGINAL ORIENTATION
AutoCAD SHX Text
ROTATION CONNECTION-CANOPY PROTECTION BAR SHALL FREELY ROTATE AND PIVOT BACK TO ORIGINAL ORIENTATION
AutoCAD SHX Text
ORDER CONFIRMATION AND SPEAKER PEDESTAL
AutoCAD SHX Text
FINAL GRADE
AutoCAD SHX Text
01
AutoCAD SHX Text
AS3.1
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
24" CONCRETE PIER W/ 8-#7 VERT. & #3 TIES @ 12" O.C.
AutoCAD SHX Text
PAVEMENT
AutoCAD SHX Text
9'-0 "38"
AutoCAD SHX Text
9'-0 "38"
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
OPTIONAL CONCRETE SLAB SPEC 1. CONCRETE SLAB TO BE A MINIMUM OF 5" THICK - VERIFY CONCRETE SLAB TO BE A MINIMUM OF 5" THICK - VERIFY SLAB REQUIREMENTS WITH GEOTECHNICAL REPORT. 2. CONCRETE SEALER: 'SCOFIELD' CEMENTONE CLEAR SEALER. CONCRETE SEALER: 'SCOFIELD' CEMENTONE CLEAR SEALER. APPLY PER MANUFACTURER'S RECOMMENDATIONS. 3. OPTIONAL: CONCRETE COLOR HARDENER: 'SCOFIELD' OPTIONAL: CONCRETE COLOR HARDENER: 'SCOFIELD' LITHOCHROME, A33 "CLASSIC GREY" APPLY PER MANUFACTURERS RECOMMENDATIONS.
AutoCAD SHX Text
DETECTOR LOOP NOTES: 1. LOOP SHOULD BEGIN 12' TO 18' OUT FROM CURB. LOOP SHOULD BEGIN 12' TO 18' OUT FROM CURB. 2. INSTALL LOOP TO BE 2" BELOW TOP OF PAVEMENT INSTALL LOOP TO BE 2" BELOW TOP OF PAVEMENT 3. THE FORWARD EDGE OF THE LOOP SHOULD BE LINED UP THE FORWARD EDGE OF THE LOOP SHOULD BE LINED UP WITH CENTERLINE OF THE D/T WINDOW OR SPEAKER PEDESTAL 4. A 3' AREA FROM THE LOOP MUST BE KEPT CLEAR OF A 3' AREA FROM THE LOOP MUST BE KEPT CLEAR OF METAL, INCLUDING REBAR, REINFORCING MESH, OTHER ELECTRICAL CABLES OR CONDUIT. 5. SEE DETECTOR LOOP MANUFACTURER'S INSTALLATION SEE DETECTOR LOOP MANUFACTURER'S INSTALLATION INSTRUCTION FOR ADDITIONAL INFORMATION
AutoCAD SHX Text
PRE-SELL BOARD
AutoCAD SHX Text
CURB LINE
AutoCAD SHX Text
ORDER STATION CANOPY. REF: 03/AS3.1
AutoCAD SHX Text
CONCRETE PAD
AutoCAD SHX Text
SIGN CABINET
AutoCAD SHX Text
CONCRETE PIER REF. 06/AS3.1
AutoCAD SHX Text
ORDER CONFIRMATION PEDESTAL
AutoCAD SHX Text
BASE BY CANOPY VENDOR
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
45°
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
NOTE: SEE G2.1 RESPONSIBILITY SCHEDULE FOR ADDITIONAL INFORMATION
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
PICK-UP WINDOW
AutoCAD SHX Text
8" HIGH LETTERING IN NUTRAFACE BOLD FONT
AutoCAD SHX Text
Sign Elev.
AutoCAD SHX Text
SCALE : 3/8" = 1'-0"
AutoCAD SHX Text
AS3.1
AutoCAD SHX Text
9
AutoCAD SHX Text
EX. SIGN STRUCT., CASE, GRAPHICS & ELEC. TO REMAIN
AutoCAD SHX Text
WENDY'S TO ATTACH NEW TWO-SIDED SIGN CASE (W/ GRAPHICS AS DIRECTED BY OWNER) TO EX. SIGN CASE, MATCH EX. DEPTH
AutoCAD SHX Text
Sign Elev.
AutoCAD SHX Text
SCALE : 3/8" = 1'-0"
AutoCAD SHX Text
AS3.1
AutoCAD SHX Text
10
AutoCAD SHX Text
EX. SIGN STRUCT., CASE, & ELEC. TO REMAIN
AutoCAD SHX Text
WENDY'S TO REPLACE EX. SIGN GRAPHICS EA. SIDE AS DIRECTED BY OWNER
AutoCAD SHX Text
FIELD VERIFY ALL EXISTING DIMENSIONS & CONDITIONS
AutoCAD SHX Text
VERIFY EX. STRUCT. & ELEC. WILL SUPPORT/SERVE NEW CASE ADDITION
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
Sign Elev.
AutoCAD SHX Text
SCALE : 1/4" = 1'-0"
AutoCAD SHX Text
AS3.1
AutoCAD SHX Text
11
AutoCAD SHX Text
EX. SIGN STRUCT., CASE, GRAPHICS & ELEC. TO REMAIN
AutoCAD SHX Text
WENDY'S TO REMOVE EX. TWO-SIDED LED GAS PRICE LIGHTS & ADJACENT SIGNAGE & REPLACE W/ TWO-SIDED GRAPHICS AS DIRECTED BY OWNER WITHIN EX. SIGN CASE
AutoCAD SHX Text
1
AutoCAD SHX Text
2810 DUNIVEN CIRCLE, SUITE 100.
AutoCAD SHX Text
LAVIN ASSOCIATES, INC.
AutoCAD SHX Text
AMARILLO, TEXAS (806) 358-7069
AutoCAD SHX Text
tion to the architect.
AutoCAD SHX Text
C
AutoCAD SHX Text
These plans & accom-
AutoCAD SHX Text
panying specifications
AutoCAD SHX Text
shall remain the proper-
AutoCAD SHX Text
ty of the architect and
AutoCAD SHX Text
shall not be used for
AutoCAD SHX Text
the construction of any
AutoCAD SHX Text
building other than the
AutoCAD SHX Text
building specified with-
AutoCAD SHX Text
out proper compensa-
AutoCAD SHX Text
ARCHITECTURE
AutoCAD SHX Text
1
AutoCAD SHX Text
ADDENDUM #1: 4/3/2020
Page 4: E hD EK X KEFrozen Bun Alt. Existing Dumpster location (dumpsters accessed from alley) 11 AS3.1 9 AS3.1 10 AS3.1 EX. BOLLARD @ DUW TO REMAIN PICK-UP WINDOW R R CONVERSION REMODEL E2000

REGIS

TERED ARCHI TEC

T

STATE

OF TE

XAS

3/17/2020

SEAL

DESCRIPTIONDATEREV.

ISSUE DATE: 3/17/2020

PROJECT NUMBER: 2019-16

DRAWN BY:

CHECKED BY:

SHEET NAME

SHEET NUMBER

SITE NUMBER:

BASE MDL:

OWNER:

BASE VERSION:

DRAWING RELEASE

PROJECT YEAR:

ASSET TYPE:

CLASSIFICATION:

UPGRADE CLASSIFICATION:

FURNITURE PACKAGE:

2401

SO

UTH

MA

IN S

TRE

ET

PE

RR

YTO

N, T

EX

AS

, 790

70

PROJECT TYPE:

12245

REMODEL E2000

FRANCHISEE

CONVERSION

TOOT N TOTUM

2019 FALL

CONVERSION

2020

UM BRIGHT

SPRING 2020

CONVERSIONREMODEL E2000

A1.1DEMOLITION PLAN

01DEMOLITION PLANSCALE: 1/4" = 1'-0" NORTH

AutoCAD SHX Text
NO WORK IN
AutoCAD SHX Text
HATCHED AREA
AutoCAD SHX Text
NO WORK IN
AutoCAD SHX Text
HATCHED AREA
AutoCAD SHX Text
Floor Plan Demolition Notes:
AutoCAD SHX Text
REMOVE EXISTING WALL AS SHOWN DASHED - PATCH ALL ADJACENT SURFACES W/ FINISH TO MATCH EXISTING OR AS OTHERWISE NOTED. REMOVE ANY EXISTING MILLWORK, EQUIPMENT, ETC. - DISPOSE OF AS PER OWNER. REMOVE ALL EXISTING FLOOR COVERING AND BASE - SEE FLOOR PLANS FOR NEW FINISHES - PREP SLAB FOR NEW FINISH TYPICAL. REMOVE EXISTING LAY-IN CEILING, GRID, DIFFUSERS, RETURNS, LIGHT FIXTURES, ETC. - PROVIDE NEW CEILING AS SHOWN ON REFLECTED CEILING PLAN. REMOVE SECTION OF EXISTING WALL FOR NEW DOOR/WINDOW - SEE FLOOR PLAN. REMOVE EXISTING DOOR FRAME OR CASED OPENING. SALVAGE AND RETURN TO OWNER. REMOVE EXISTING ALUMINUM STOREFRONT. REMOVE AND SALVAGE EXISTING ALUMINUM STOREFRONT WINDOW FOR REUSE. REMOVE EXISTING FLOOR SINK/ DRAIN. REFER TO PLUMBING DRAWINGS. REMOVE EXISTING AWNINGS AND LIGHT FIXTURES ABOVE. NOT USED. REMOVE CMU BLOCK AND 1 1/2" RIGID INSULATION SHOWN DASHED AND PREPARE FOR NEW CONSTRUCTION. SALVAGE CMU AND REUSE AS NEEDED. SEE WALL SECTIONS.
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
OWNER TO REMOVE AND SALVAGE EXISTING KITCHEN EQUIPMENT, RACKS, SHELVES, ETC. PREPARE FOR NEW CONSTRUCTION. OWNER TO REMOVE EXISTING AWNING AS REQUIRED FOR CMU REMOVAL AND INSTALLATION OF NEW PANELS. STOCKPILE AND PROTECT DURING CONSTRUCTION. OWNER TO REINSTALL AWNING AFTER NEW PANELS ARE INSTALLED. EXISTING FLOOR FINISH TO REMAIN. EXISTING WALL TO REMAIN. EXISTING CEILING TILE AND GRID TO REMAIN. EXISTING COLUMN TO REMAIN. EXISTING FLOOR SINK/ DRAIN TO REMAIN. REMOVE EXISTING CEILING TILES. EXISTING CEILING GRID TO REMAIN. REMOVE EXISTING WALL FINISHES AND BASE. PREPARE EXISTING WALL FOR NEW FINISHES. RE: FINISH SCHEDULE. REMOVE EXISTING FLOOR FINISH THIS AREA. PREPARE FLOOR FOR NEW FINISH. REMOVE EXISTING SOLID SURFACE SILL. PREPARE FOR NEW WINDOW SILL AS SCHEDULED. REMOVE AND SALVAGE EXISTING 3 COMPARTMENT SINK. COORDINATE WITH OWNER. REFER TO PLUMBING DRAWINGS. REMOVE EXISTING WALL APPLIED GRAPHIC. PATCH AND PREPARE FOR NEW FINISH AND GRAPHICS. SEE INTERIOR ELEVATIONS.
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
21
AutoCAD SHX Text
22
AutoCAD SHX Text
23
AutoCAD SHX Text
20
AutoCAD SHX Text
24
AutoCAD SHX Text
25
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
2810 DUNIVEN CIRCLE, SUITE 100.
AutoCAD SHX Text
LAVIN ASSOCIATES, INC.
AutoCAD SHX Text
AMARILLO, TEXAS (806) 358-7069
AutoCAD SHX Text
tion to the architect.
AutoCAD SHX Text
C
AutoCAD SHX Text
These plans & accom-
AutoCAD SHX Text
panying specifications
AutoCAD SHX Text
shall remain the proper-
AutoCAD SHX Text
ty of the architect and
AutoCAD SHX Text
shall not be used for
AutoCAD SHX Text
the construction of any
AutoCAD SHX Text
building other than the
AutoCAD SHX Text
building specified with-
AutoCAD SHX Text
out proper compensa-
AutoCAD SHX Text
ARCHITECTURE
AutoCAD SHX Text
1
AutoCAD SHX Text
ADDENDUM #1: 4/3/2020
Page 5: E hD EK X KEFrozen Bun Alt. Existing Dumpster location (dumpsters accessed from alley) 11 AS3.1 9 AS3.1 10 AS3.1 EX. BOLLARD @ DUW TO REMAIN PICK-UP WINDOW R R CONVERSION REMODEL E2000

REGIS

TERED ARCHI TEC

T

STATE

OF TE

XAS

3/17/2020

SEAL

DESCRIPTIONDATEREV.

ISSUE DATE: 3/17/2020

PROJECT NUMBER: 2019-16

DRAWN BY:

CHECKED BY:

SHEET NAME

SHEET NUMBER

SITE NUMBER:

BASE MDL:

OWNER:

BASE VERSION:

DRAWING RELEASE

PROJECT YEAR:

ASSET TYPE:

CLASSIFICATION:

UPGRADE CLASSIFICATION:

FURNITURE PACKAGE:

2401

SO

UTH

MA

IN S

TRE

ET

PE

RR

YTO

N, T

EX

AS

, 790

70

PROJECT TYPE:

12245

REMODEL E2000

FRANCHISEE

CONVERSION

TOOT N TOTUM

2019 FALL

CONVERSION

2020

UM BRIGHT

SPRING 2020

CONVERSIONREMODEL E2000

A1.2FLOOR PLAN

01FLOOR PLANSCALE: 1/4" = 1'-0" NORTH

AutoCAD SHX Text
NO WORK IN
AutoCAD SHX Text
HATCHED AREA
AutoCAD SHX Text
1
AutoCAD SHX Text
A3.2
AutoCAD SHX Text
2
AutoCAD SHX Text
A3.2
AutoCAD SHX Text
NO WORK IN
AutoCAD SHX Text
HATCHED AREA
AutoCAD SHX Text
1
AutoCAD SHX Text
A6.1
AutoCAD SHX Text
2
AutoCAD SHX Text
A6.1
AutoCAD SHX Text
3
AutoCAD SHX Text
A6.1
AutoCAD SHX Text
5
AutoCAD SHX Text
A6.1
AutoCAD SHX Text
4
AutoCAD SHX Text
A6.1
AutoCAD SHX Text
1
AutoCAD SHX Text
A3.2
AutoCAD SHX Text
3
AutoCAD SHX Text
A3.2
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
2
AutoCAD SHX Text
A6.1
AutoCAD SHX Text
5
AutoCAD SHX Text
A6.1
AutoCAD SHX Text
6
AutoCAD SHX Text
A6.1
AutoCAD SHX Text
7
AutoCAD SHX Text
A7.1
AutoCAD SHX Text
8
AutoCAD SHX Text
A6.1
AutoCAD SHX Text
11
AutoCAD SHX Text
A6.1
AutoCAD SHX Text
9
AutoCAD SHX Text
A9.1
AutoCAD SHX Text
10
AutoCAD SHX Text
A6.1
AutoCAD SHX Text
13
AutoCAD SHX Text
A6.1
AutoCAD SHX Text
12
AutoCAD SHX Text
A6.1
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
SIM.
AutoCAD SHX Text
3
AutoCAD SHX Text
A4.1
AutoCAD SHX Text
4
AutoCAD SHX Text
A4.1
AutoCAD SHX Text
3
AutoCAD SHX Text
A4.1
AutoCAD SHX Text
4
AutoCAD SHX Text
A4.1
AutoCAD SHX Text
8
AutoCAD SHX Text
A6.3
AutoCAD SHX Text
10
AutoCAD SHX Text
A6.3
AutoCAD SHX Text
Floor Plan Notes:
AutoCAD SHX Text
APPROXIMATE LOCATION OF FRONT COUNTER. ALIGN FINISHES SOFFIT OR BULKHEAD ABOVE, REFER TO REFLECTED CEILING PLAN. NEW EXHAUST HOOD. REFER TO MEP DRAWINGS. WENDY'S TO PROVIDE AND INSTALL STAINLESS STEEL PANELS. REFER TO INTERIOR ELEVATIONS. CROSS HATCHED AREA INDICATES EXTENTS OF METAL STUD FRAMED WALL W/ MINERAL WOOL RIGID INSULATION. EQUIPMENT CURB BY KITCHEN VENDOR. REF. SHEET A5.1 FOR LOCATIONS. AWNING / CANOPY ABOVE.
AutoCAD SHX Text
EXISTING FLOOR SINK/ DRAIN TO REMAIN. NOT USED. NEW ELECTRICAL PANEL, SEE ELECTRICAL DRAWINGS. WENDY'S TO PROVIDE NEW EVAPORATOR, INSULATED FLOOR, RAMP, ETC. FOR NEW FREEZER.
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
2810 DUNIVEN CIRCLE, SUITE 100.
AutoCAD SHX Text
LAVIN ASSOCIATES, INC.
AutoCAD SHX Text
AMARILLO, TEXAS (806) 358-7069
AutoCAD SHX Text
tion to the architect.
AutoCAD SHX Text
C
AutoCAD SHX Text
These plans & accom-
AutoCAD SHX Text
panying specifications
AutoCAD SHX Text
shall remain the proper-
AutoCAD SHX Text
ty of the architect and
AutoCAD SHX Text
shall not be used for
AutoCAD SHX Text
the construction of any
AutoCAD SHX Text
building other than the
AutoCAD SHX Text
building specified with-
AutoCAD SHX Text
out proper compensa-
AutoCAD SHX Text
ARCHITECTURE
AutoCAD SHX Text
Wall Legend
AutoCAD SHX Text
NOTE: ALL INTERIOR WALLS TO HAVE 3-1/2" S.A. BATTS, U.N.O.
AutoCAD SHX Text
EXISTING EXTERIOR WALL - 5/8" GYP. BD. (INTERIOR)
AutoCAD SHX Text
OVER 6" 18 GA. METAL STUDS @ 16" O.C. W/ 1/2" SHEATHING,
AutoCAD SHX Text
1-1/2" RIGID INSULATION, AIR SPACE, & BLOCK VENEER -
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
NEW EXTERIOR WALL - 5/8" GYP. BD. (INTERIOR)
AutoCAD SHX Text
OVER 6" 18 GA. METAL STUDS @ 16" O.C. W/ MINERAL WOOL
AutoCAD SHX Text
RIGID INSULATION, 1/2" SHEATHING, 1-1/2" RIGID INSULATION,
AutoCAD SHX Text
AIR SPACE & SALVAGED BLOCK VENEER - SEE WALL
AutoCAD SHX Text
NEW EXTERIOR WALL - 5/8" GYP. BD. (INTERIOR)
AutoCAD SHX Text
OVER 6" 18 GA. METAL STUDS @ 16" O.C., 7/8" FURRING
AutoCAD SHX Text
CHANNELS @ 16" O.C. VERTICAL, 3-5/8" 20 GA. METAL STUDS
AutoCAD SHX Text
ALIGNED W/ EXISTING 6" METAL STUDS, 1/2" EXTERIOR
AutoCAD SHX Text
W/ 5/8" GYP. BOARD EACH SIDE (VERIFY STUD WIDTH
AutoCAD SHX Text
EXISTING 3-5/8", 6", & 8" 20 GA. METAL STUDS AT 16" O.C.
AutoCAD SHX Text
ON FLOOR PLAN)
AutoCAD SHX Text
GYP. BOARD EACH SIDE. ALL STUDS TO DECK.
AutoCAD SHX Text
NEW 3-5/8", 6", & 8" 20 GA. METAL STUDS AT 16" O.C. W/ 5/8"
AutoCAD SHX Text
(VERIFY STUD WIDTH ON FLOOR PLAN)
AutoCAD SHX Text
GRADE PLYWD. OVER 1-1/2" R-7.5 RIGID INSULATION OVER
AutoCAD SHX Text
1/2" EXTERIOR GRADE PLYWD., FIBER CEMENT FINISH
AutoCAD SHX Text
PANELS
AutoCAD SHX Text
SECTIONS
AutoCAD SHX Text
MINERAL WOOL RIGID INSULATION, 5/8" GYP. BOARD EACH
AutoCAD SHX Text
NEW 3-5/8", 6", & 8" 20 GA. METAL STUDS AT 16" O.C. W/
AutoCAD SHX Text
SIDE. ALL STUDS TO DECK. (VERIFY STUD WIDTH ON FLOOR
AutoCAD SHX Text
PLAN)
AutoCAD SHX Text
1
AutoCAD SHX Text
ADDENDUM #1: 4/3/2020
Page 6: E hD EK X KEFrozen Bun Alt. Existing Dumpster location (dumpsters accessed from alley) 11 AS3.1 9 AS3.1 10 AS3.1 EX. BOLLARD @ DUW TO REMAIN PICK-UP WINDOW R R CONVERSION REMODEL E2000

GENERAL NOTES

A. PAY ALL FEES AND ARRANGE FOR EXECUTION OF ALL TAPS, METERS WITH REQUIRED

ENCLOSURES (IF ANY), AND APPURTENANCES INHERENT TO THE INSTALLATION OF PLUMBING

SERVICE.

B. PROVIDE ALL LABOR, EQUIPMENT, AND MATERIALS NECESSARY TO EXECUTE THE PLUMBING

WORK INDICATED ON THE DRAWINGS AS SPECIFIED, AND AS REQUIRED BY LOCAL CODES AND

ORDINANCES. PLUMBING WORK SHALL INCLUDE ALL PIPING FOR DOMESTIC HOT AND COLD

WATER LINES, VENT AND SANITARY LINES, HOOK-UP OF ALL FIXTURES SCHEDULED ON THE

DRAWINGS, AND INSULATION OF DESIGNATED PIPING. WORK SHALL ALSO INCLUDE ALL GAS

PIPING AND EQUIPMENT CONNECTIONS WHERE REQUIRED. INCLUDE ALL ITEMS SUCH AS

FITTINGS NOT MENTIONED BUT UNDERSTOOD TO BE NECESSARY TO COMPLETE THE

PLUMBING SYSTEM. COORDINATE ALL WORK WITH OTHER CONTRACTORS.

C. PROVIDE FOR DRAINING WATER SYSTEM AND CAP ALL STUBS UNTIL FINISH WORK IS

INSTALLED. INSTALL DRAIN VALVE AT WATER METER WITH 3/4" HOSE THREAD AND VACUUM

BREAKER.

D. PROVIDE VALVES ON WATER SUPPLIES TO EACH FIXTURE & EQUIPMENT. VALVES SHALL BE 1/4

TURN SHUT-OFF VALVES.

E. INSULATE ALL PIPING PER SPECIFICATIONS.

F. PLUMBING FIXTURES SHALL BE PROVIDED WHERE SHOWN ON DRAWINGS. FIXTURE FITTINGS

AND EXPOSED FIXTURE PIPING SHALL BE BRASS CHROMIUM PLATED. TRAPS SHALL BE CAST

BRASS. FIXTURES SHALL BE EQUAL IN ALL RESPECTS TO FIXTURES SPECIFIED.

G. PROVIDE ROUGH-IN AND FINAL CONNECTIONS OF REQUIRED WASTE, VENT, AND WATER

SUPPLY PIPING.

H. THIS CONTRACTOR SHALL GUARANTEE ALL WORK INSTALLED UNDER THE CONTRACT TO BE

FREE FROM DEFECTIVE WORKMANSHIP AND MATERIALS, (USUAL WEAR IS EXPECTED), AND

SHOULD DEFECTS DEVELOP WITHIN A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF THE

BUILDING BY THE OWNER, THIS CONTRACTOR SHALL REPAIR AND/OR REPLACE DEFECTIVE

ITEMS AND ALL DAMAGE RESULTING FROM FAILURE OF THESE ITEMS, AT NO EXPENSE

WHATSOEVER TO THE OWNER

I. THE DIRECTION OF THE SANITARY MAIN AND THE LOCATION OF THE GREASE INTERCEPTOR

SHALL BE COORDINATED WITH CIVIL DRAWINGS PRIOR TO ROUGH-IN.

J. PROVIDE PROVENT TRAP GUARD (OR APPROVED EQUAL) AT ALL FLOOR DRAINS. PROVIDE

TRAP PRIMERS ON FLOOR DRAINS ONLY IF REQUIRED BY AUTHORITY HAVING JURISDICTION

(AHJ). IF AHJ REQUIRES TRAP PRIMERS, LAYOUT DISTRIBUTION TO CONNECT MULTIPLE FLOOR

DRAINS TO ONE TRAP PRIMER.

K. COORDINATE LOCATION AND ROUGH-IN HEIGHT OF KITCHEN EQUIPMENT WITH OWNER AND

MILLWORK PRIOR TO ROUGH-IN.

L. PROVIDE WATER HAMMER ARRESTORS AT END RUN OF ALL WATER PIPING. SIZE AND LOCATE

AS RECOMMENDED BY PLUMBING AND DRAINAGE INSTITUTE STANDARD PDI-WH201, AND AS

RECOMMENDED BY THE MANUFACTURER.

M. ALL PIPING (GAS AND WATER) SHALL BE CONCEALED IN WALL SPACE WHEN POSSIBLE,

UNLESS NOTED OTHERWISE.

N. DAMAGES TO EXISTING WALLS, FLOORS, FINISHES ETC. BY THIS CONTRACTOR SHALL BE

REPAIRED AT THIS CONTRACTOR'S EXPENSE.

O. WATER HEATER, WATER METER AND BACKFLOW PREVENTER SHALL BE INSTALLED TO MEET

ALL STATE, COUNTY AND LOCAL JURISDICTION CODES.

P. ON ALL SYNFLEX LINE INSTALLATIONS (EXCEPT DRINK STATIONS AND COFFEE BREWER)

TRANSITION TO COPPER AT TOP OF WALL, AND ROUTE DOWN INSIDE WALL AND THEN

THROUGH WALL TO EXPOSED SHUT OFF VALVE. DRINK STATIONS WILL HAVE SYNFLEX LINES

FROM FILTER TO UNIT INSTALLED BY BEVERAGE SYSTEM INSTALLER.

Q. 3 COMP SINK, COMBI OVEN AND 2 AREA FLOOR DRAINS BETWEEN HOOD AREA SHALL BE

ROUTED TO GREASE WASTE LINE. ALL OTHER DRAINS SHALL BE ROUTED TO BUILDING

SANITARY.

R. ALL WATER SUPPLY LINES, VENT STACK LINES, SANITARY LINES, AND OTHER EXPOSED

PLUMBING LINES SHALL BE COMPLETELY SEALED AT ALL WALL PENETRATIONS. PROVIDE

CHROME ESCUTCHEON PLATE SEALED TO WALL WITH SILICONE SEALANT.

S. SEE CONNECTION SCHEDULE FOR ALL INDIVIDUAL PIPE SIZES.

REMARKS (#)

FIXTURE & EQUIPMENT CONNECTION SCHEDULE

SY

MB

OL

QU

AN

TIT

Y

GENERAL FIXTURE DESCRIPTION

DOMESTIC WATER SANITARY

NATURAL

GAS

US

ED

C

OO

KIN

G O

IL

REMARKS (#)

FIL

TE

RE

D W

AT

ER

- F

CW

1

FIL

TE

RE

D W

AT

ER

- F

CW

2

FIL

TE

RE

D W

AT

ER

- F

CW

3

FIL

TE

RE

D W

AT

ER

- F

CW

4

CO

LD

W

AT

ER

HO

T W

AT

ER

(1

40

°)

HO

T W

AT

ER

(1

10

°)

MO

UN

TIN

G H

EIG

HT

DR

AIN

L

IN

E S

IZ

E

TR

AP

FIX

TU

RE

D

RA

IN

DIR

EC

T / IN

DIR

EC

T (D

/I)

SA

NIT

AR

Y / G

RE

AS

E (S

/G

)

VE

NT

MO

UN

TIN

G H

EIG

HT

CO

NN

EC

TIO

N S

IZ

E

BT

U L

OA

D

PLUMBING FIXTURES

WC0

WATER CLOSET (ACCESSIBLE)

1

1

4

"

(1)

4" INT 4" D S 2" FL

(3), (5), (6)

LAV-10 LAVATORY

1

2

"

1

2

"

(1)

1

1

2

" 1

1

2

" 1

1

2

" D S 1

1

2

"

(1) (3), (5), (6)

LAV-20 LAVATORY

1

2

"

1

2

"

(1)

1

1

2

" 1

1

2

" 1

1

2

" D S 1

1

2

"

(1) (3), (5), (6)

FPWH0 FROST PROOF WALL HYDRANT

3

4

" 18"

(3), (5), (6)

PLUMBING DRAINS

FD0 FLOOR DRAIN 3" 3" * 1

1

2

" FL

(3), (8), (9)

FS-13 FLOOR SINK 3" 3" * 1

1

2

" FL

(3), (8), (9)

FS-20 FLOOR SINK 3" 3" * 1

1

2

" FL

(3), (8), (9)

HD1 HUB DRAIN 3" 3" * 1

1

2

" 12"

(3), (8), (9)

KITCHEN EQUIPMENT - FRONT COUNTER

E2302 1 BACK COUNTER HAND SINK

1

2

"

1

2

" 14" 2" 1

1

2

" 1

1

2

" D S 1

1

2

" 12"

(4), (6), (8), (9),

(16)

KITCHEN EQUIPMENT - BEVERAGE LINE

A0105 1

BEVERAGE SYSTEM (DRIVE-THRU)

1

2

" I S

(4), (14), (15)

A0608 1 COFFEE BREWER

1

2

"

(4), (10), (13)

E4003 1 DRIVE-THRU HAND SINK ASSEMBLY

1

2

"

1

2

" 14" 2" 1

1

2

" 1

1

2

" D S 1

1

2

"

(4), (8), (9),

(16)

KITCHEN EQUIPMENT - FRYLINE

J1003 1 OPEN FRYER - 3 WELL 1" 225K *

(4)

J1008 1 PRESSURE FRYER

1

2

" 80K *

(4)

K1401 1 COMBI OVEN

1

2

"

1

2

" 30" 3" 3" I G 1

1

2

"

(4), (10), (13)

KITCHEN EQUIPMENT - PREP AREA / WAREWASH

A0801 1 TEA BREWER *

1

2

"

(4), (10), (13)

T1213 1

CHEMICAL BLEND STATION (FOR

T2011)

1

2

"

1

2

" 54"

(4), (16)

T0901 1 2 COMP PREP SINK

1

2

"

1

2

" 14"

(4), (6), (7), (8),

(9), (16)

T2011 1 3 COMP SINK

1

2

"

1

2

" 14"

(4), (6), (7), (8),

(9), (16)

T2061 1 WAREWASH MACHINE

1

2

"

1

2

" 10" 3" 3" 2" I G 1

1

2

"

(4), (6), (7), (8),

(9), (10), (16)

KITCHEN EQUIPMENT - HAND SINK

T2702 1 HAND SINK

1

2

"

1

2

" 2" 1

1

2

" 1

1

2

" D S 1

1

2

" 12"

(4), (6), (8), (9),

(16)

KITCHEN EQUIPMENT - DRINK EQUIPMENT

QP0909 1

ICE MAKER (CUBER) - KITCHEN

1

2

" 72" 3" 3"

3

4

" I S 1

1

2

"

(4), (6), (7),

(10), (13)

T2212 1 WATER TREATMENT UNIT

3

4

"

(4), (11), (13),

(16)

KITCHEN EQUIPMENT - MOP SINK / CLEANING EQUIPMENT

T0303 1

MOP SINK FAUCET (FOR T0602 -

LOWER)

1

2

"

1

2

" 36"

(4), (6), (16)

T0304 1

MOP SINK FAUCET (FOR T0602 -

UPPER BLEND CENTER)

1

2

"

1

2

" 54"

(4), (6), (16)

T0602 1 MOP SINK 3" 3" 3" D S 1

1

2

" FL

(4), (6), (16)

T1212 1 CHEMICAL BLEND CENTER

1

2

"

1

2

" 54"

(4), (16)

T2213 1 REVERSE OSMOSIS SYSTEM

1

2

"

1

2

"

(16), (12)

A0304 1 BAG-IN-BOX

1

2

"

(4), (11), (16)

*VERIFY QUANTITIES WITH ARCHITECTURAL EQUIPMENT PLAN AND SCHEDULE.*

1. MOUNTING HEIGHT AS DIRECTED BY EQUIPMENT SUPPLIER.

2. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS.

3. EQUIPMENT FURNISHED BY PLUMBING CONTRACTOR.

4. EQUIPMENT FURNISHED BY OTHERS.

5. REFER TO PLUMBING FIXTURE SCHEDULE.

6. PROVIDE VALVE AT EACH CONNECTION TO EQUIPMENT.

7. PLUMBING CONTRACTOR TO PROVIDE INDIRECT DRAIN TO

FLOOR DRAIN OR SINK.

8. VERIFY DIRECT OR INDIRECT WASTE CONNECTION PER LOCAL

CODE REQUIREMENTS.

9. VERIFY SANITARY OR GREASE WASTE CONNECTION PER

LOCAL CODE REQUIREMENTS.

10. SHUTOFF VALVE AND FLEX CONNECTOR LINES TO PRE-RINSE

ARE PROVIDED WITH FIXTURE.

11. PROVIDE WITH WATTS NO. 009 BACKFLOW PREVENTER IF

REQUIRED BY CODE.

12. PROVIDE WITH WATTS NO. 0009 BACKFLOW PREVENTER WHEN

LOCAL JURISDICTION REQUIRES A HIGHER LEVEL OF

PROTECTION THAN PROVIDED BY THE INTEGRAL ASSE 1022

DOUBLE CHECK VALVE.

13. PLUMBING CONTRACTOR TO RUN WATER LINE TO FILTRATION

SYSTEM WITH FINAL CONNECTIONS BY BEVERAGE INSTALLER.

14. BEVERAGE INSTALLER TO ROUTE LINE TO POINT OF USE AND

PLUMBING CONTRACTOR TO MAKE FINAL CONNECTION.

15. WATER SUPPLY LINE IS PART OF THE BEVERAGE BUNDLE.

16. PLUMBING CONTRACTOR TO MAKE FINAL CONNECTIONS TO

EQUIPMENT.

17. CONTACT EQUIPMENT CONSOLIDATOR - SEE SHEET G1.1. IF

FIXTURES ARE NOT AVAILABLE LOCALLY. REFER TO BID

DOCUMENTS IF GENERAL CONTRACTOR OR OWNER WILL

PROVIDE EQUIPMENT THROUGH CONSOLIDATOR.

*NOT ALL SYMBOLS OR LINETYPES ARE NECESSARILY USED*

PLUMBING SYMBOLS LEGEND

BV BALL VALVE

GW

D

G

UCO

FW

SANITARY WASTE (SAN) - BELOW SLAB/GRADE

PLUMBING VENT (V) - BELOW SLAB/GRADE

GREASE WASTE (GW) - BELOW SLAB/GRADE

USED COOKING OIL (UCO)

PLUMBING VENT (V)

CONDENSATE LINE (D)

HOT WATER RETURN (HWR) 140°, 120°

GAS LINE (G)

SYNFLEX (SYN) [BY OTHERS]

FILTERED WATER SUPPLY (FW)

HOT WATER (HW) 140°, 120°

COLD WATER (CW) - BELOW SLAB/GRADE

COLD WATER (CW)

SYN

BFP

RI

BACKFLOW PREVENTER

ROUGH-IN

AFF/AFG

FCO/ECO

VTR

IW

WCO/CO

ABOVE FINISHED FLOOR/GRADE

FLOOR/EXTERIOR CLEANOUT

WALL CLEANOUT/ CLEANOUT

VENT THRU ROOF

INDIRECT WASTE

TYPICALTYP

AHJ

UNO

AUTHORITY HAVING JURISDICTION

UNLESS NOTED OTHERWISE

ABBREVIATIONS: LINETYPES:

END CAP

SHUTOFF VALVE (BALL TYPE)

TEE TURNING UP/DOWN

PIPE TURNING UP/DOWN

CHECK VALVE

BALANCING VALVE

PIPE SYMBOLS:

WALL HYDRANT

PUMP SCHEDULE

SYMBOL MANUF. MODEL GPM

HEAD

(FT)

HP RPM V PH FLA

NOTES

(#)

RCP

BELL &

GOSSETT

100 5 12

1

12

1725 115 1 1.75

(1)

NOTES:

1. RECIRCULATING PUMP: BRONZE BODY RECIRCULATING PUMP, INSTALL NEAR WATER HEATER

PER MANUFACTURER'S INSTRUCTIONS. PROVIDE WITH AQUASTAT SET TO 5°F BELOW WATER

HEATER OPERATING TEMPERATURE.

PLUMBING FIXTURE SCHEDULE

SYMBOL FIXTURE TYPE MANUF. MODEL DESCRIPTION ACCESSORIES/OPTIONS

NOTES (#)

FPWH

FROST PROOF

WALL HYDRANT

WOODFORD MODEL 65

ANTI-SIPHON, AUTOMATIC DRAINING, WALL HYDRANT,

NON-FREEZE INTEGRAL VACUUM BREAKER, ALL BRONZE

INTERIOR PARTS, KEY OPERATED, 3/4" SOLDER INLET.

MOUNT 18" ABOVE FINISHED GRADE. PROVIDE

APPROPRIATE MODEL FOR WALL THICKNESS AND SITE

SPECIFIC TEMPERATURE REQUIREMENTS.

FDFLOOR DRAIN

SIOUX CHIEF /

ZURN

832-35D-NR /

#ZN415-B-3NH

FLOOR DRAIN WITH 5" ROUND NICKEL BRONZE ADJUSTABLE

STRAINER AND CAST IRON BODY & 3" BOTTOM OUTLET.

PROVIDE WITH ASSE 1072 APPROVED TRAP SEAL DEVICE.

TRAP SEAL DEVICE SHALL BE TRAP PROSET TRAPGUARD

OR APPROVED EQUAL. INSTALL PER MANUFACTURER'S

RECOMMENDATIONS. PROVIDE DRAINS IN CUSTOMER

AREAS WITH VANDAL RESISTANT SCREWS.

FS-1FLOOR SINK

SIOUX CHIEF /

ZURN

#861-3PN-D /

#Z1900-3NH-K-4

12" SQUARE TOP FLOOR SINK W/8" DEEP PVC/CAST IRON BODY &

3" BOTTOM OUTLET (CAST IRON OPTIONAL)

FS-2FLOOR SINK

SIOUX CHIEF /

ZURN

#861-23X-N2 /

#Z1900-3NH-2NB

12" SQUARE TOP FLOOR SINK WITH 6" DEEP ACID RESISTANT

ENAMEL CAST IRON BODY AND 3"OUTLET WITH

1

2

NICKEL BRONZE

GRATE.

SET FLOOR SINK LEVEL WITH FINISH FLOOR.

HDHUB DRAIN N/A N/A

STUB 3" WASTE LINE 12" ABOVE FINISHED FLOOR SLAB FOR

FUTURE CONNECTIONS BY OTHERS.

PROVIDE WITH ASSE 1072 APPROVED TRAP SEAL DEVICE.

TRAP SEAL DEVICE SHALL BE TRAP PROSET TRAPGUARD

OR APPROVED EQUAL. INSTALL PER MANUFACTURER'S

RECOMMENDATIONS.

MVMIXING VALVE SYMMONS 7-225-CK "MAXLINE"

1/2" INLETS AND OUTLET, THERMOSTATIC CONTROLLER WITH

INTEGRAL CHECKS, ALL BRASS BODY WITH DUAL STAINLESS

STEEL STRAINER, VANDAL RESISTANT TEMPERATURE

ADJUSTMENT HANDLE.

SET TO 105°F. MOUNT IN ACCESSIBLE LOCATION.

GT GREASE TRAP

SCHIER

(GREAT BASIN)

GB-250

SEAMLESS MOLDED POLYETHYLENE TANK, 100 / 200 GPM FLOW

RATE, 1,751 / 1,196 LB GREASE CAPACITY, W/ BUILT-IN FLOW

CONTROL, FIELD ADJUSTABLE RISER SYSTEM, 4" PLAIN

INLET/OUTLET, WATER/GAS TIGHT SEAL COVER WITH MIN 1,000 LB

LOAD CAPACITY, CERTIFIED TO ASME A112 14.3 AND CSA B481.1

NOTES:

1. INSTALL IN ACCORDANCE TO ADA ACCESSIBILITY REQUIREMENTS.

2. PROVIDE WITH QUARTER TURN BRASS ANGLE COMPRESSION STOPS WITH LOOSE KEY HANDLES, STAINLESS BRAIDED SUPPLIES, CHROME SUPPLY AND DRAIN ESCUTCHEONS, CHROME GRID STRAINER

DRAIN WITH TAILPIECE, CHROME PLATED CAST BODY P-TRAP WITH CLEANOUT. INSULATE WASTE AND WATER PIPING WITH TRUEBRO "LAV-GUARD2" #101-EZ.

3. FURNISH WITH ZURN #Z-1231-81 LAVATORY CARRIER.

4. FURNISH WITH MANUFACTURER'S RECOMMENDED LAVATORY CARRIER.

ELECTRIC WATER HEATER SCHEDULE

SYMBOL MANUF. MODEL GAL. KW V PH

# OF

ELEMENTS

RECOVERY

(GPH/90°F)

SET POINT

(°F)

NOTES

(#)

WH-1RHEEM E-ES 120 24 240 3 6 124 140

(1), (2)

NOTES:

1. GAS FIRED WATER HEATER: THREE YEAR TANK/PARTS WARRANTY, GLASS LINED STEEL TANK,

150 PSI WORKING PRESSURE, MEETING CURRENT EDITION OF ASHRAE 90.1B AND LOCAL

ENERGY CONSERVATION REQUIREMENTS. PROVIDE T&P RELIEF VALVE.

2. FURNISH WITH EXPANSION TANK AS SPECIFIED ON PLANS.

EXPANSION TANK SCHEDULE

SYMBOL MANUF. MODEL GAL.

ACCEPT.

GAL.

CONN.

LOC.

CONN.

SIZE

MOUNTING

NOTES

(#)

ET-1AMTROL ST-8 4.4 3.2 TOP

3

4

"ABOVE WH-1 (1), (2)

ET-2AMTROL ST-5 2 0.9 TOP

3

4

"ABOVE WH-2 (1), (2)

NOTES:

1. EXPANSION TANK: STEEL SHELL, HEAVY DUTY BUTYL NSF/ANSI 61, FACTORY PRECHARGED TO

50 PSIG. MAX OPERATING TEMPERATURE 200°, MAX OPERATING PRESSURE 150 PSI, 1 YEAR

MANUFACTURER'S WARRANTY. INSTALL PER MANUFACTURER'S INSTRUCTIONS.

2. FIELD CHARGE EXPANSION TANK TO SYSTEM PRESSURE BEFORE CONNECTION TO DOMESTIC

WATER SYSTEM. FIELD VERIFY PRESSURE REQUIREMENTS.

PLUMBING SCHEDULES

AND NOTES

P1.0

SEAL

DESCRIPTIONDATEREV.

ISSUE DATE: 3/17/2020

PROJECT NUMBER: 2019-16

DRAWN BY: DW

CHECKED BY: AH

SHEET NAME

SHEET NUMBER

SITE NUMBER:

BASE MDL:

OWNER:

BASE VERSION:

DRAWING RELEASE

PROJECT YEAR:

ASSET TYPE:

CLASSIFICATION:

UPGRADE CLASSIFICATION:

FURNITURE PACKAGE:

2401 S

OU

TH

M

AIN

S

TR

EE

T

PE

RR

YT

ON

, T

EX

AS

, 79070

PROJECT TYPE:

12245

REMODEL E2000

FRANCHISEE

CONVERSION

TOOT N TOTUM

2019 FALL

CONVERSION

2020

UM BRIGHT

SPRING 2020

CONVERSION

REMODEL E2000

10755 SANDHILL ROAD

DALLAS, TEXAS 75238

O: 214-343-9400

dimensiongrp.com

4.3.2020

AutoCAD SHX Text
1
AutoCAD SHX Text
1 04.03.2020 ADDENDUM
Page 7: E hD EK X KEFrozen Bun Alt. Existing Dumpster location (dumpsters accessed from alley) 11 AS3.1 9 AS3.1 10 AS3.1 EX. BOLLARD @ DUW TO REMAIN PICK-UP WINDOW R R CONVERSION REMODEL E2000

R2

04

7

H

R0

51

1

H

R0

51

1

H

R0

51

1

H

R0

51

1

H

R0

51

1

H

R0

51

1

H

R0

51

1

H

R0

51

1

H

R0

51

1 H

R0

51

1

#

CODED NOTES:

1. EXTEND SANITARY LINE TO NEAREST MAIN OF ADEQUATE SIZE. FIELD VERIFY EXACT LOCATION, SIZE, CONDITION, AND INVERT PRIOR TO ANY WORK.

2. REPLACE EXISTING GREASE INTERCEPTOR. FIELD VERIFY SIZE, LOCATION, AND CONDITION OF THE EXISTING GREASE SYSTEM. REFER TO "GREASE INTERCEPTOR" AND "SAMPLING PORT" DETAILS

3. VENT RISER TO CONNECT WITH NEAREST EXISTING VENT MAIN OF ADEQUATE SIZE. FIELD VERIFY SIZE, LOCATION, AND CONDITION OF MAIN PRIOR TO BID.

4. EXTEND GREASE WASTE LINE TO NEAREST MAIN OF ADEQUATE SIZE. FIELD VERIFY SIZE, LOCATION, CONDITION, AND INVERT PRIOR TO ANY WORK.

5. ROUTE CONDENSATE FROM FREEZER/COOLER TO EXISTING FLOOR SINK. PROVIDE RAYCHEM GUARDIAN GM-51-IM HEAT TRACED LINE FROM INSIDE OF COOLER TO FLOOR DRAIN. (COORDINATE POWER FOR

HEAT TRACE WITH ELECTRICAL PLANS.) REFER TO "COOLER/FREEZER CONDENSATE" DETAIL.

6. USED COOKING OIL MANIFOLD (BY OTHERS) AT 24" A.F.F. RUN WASTE OIL LINE DOWN SURFACE OF WALL AS TIGHT AS POSSIBLE TO THE MANIFOLD. EXTEND LINE TO USED COOKING OIL TANK AS SHOWN.

MANIFOLD SYSTEM SUPPLIED BY EQUIPMENT SUPPLIER INSTALLED BY PLUMBING CONTRACTOR. REFER TO "USED OIL RECOVERY" DETAIL.

7. ROUTE USED COOKING OIL LINE MINIMUM OF 6" ABOVE CEILING FROM MANIFOLD TO RECOVERY TANK AS SHOWN PER PLAN. USE 3/4" BLACK IRON PIPE. SLOPE PIPING FROM MANIFOLD TO BACK OF BUILDING.

REFER TO INSTALLATION MANUAL FOR EXACT PITCH. LINE CANNOT HAVE ANY TRAPS. USE ONLY BACK TO BACK 45 DEGREE ELBOW TO CHANGE DIRECTION.

8. GENERAL CONTRACTOR TO PROVIDE PIPE DOWN WALL. MANUFACTURER TO PROVIDE STAINLESS STEEL PIPE COVER. TURN INTO TANK SHED AT 89" A.F.F. STUB OUT EXTERIOR SIDE OF WALL. PIPING TO BE 3/4"

BLACK IRON TO UNDERSIDE OF JOIST.

9. EXISTING FLOOR SINK TO REMAIN. ROUTE NEW EQUIPMENT TO EXISTING FLOOR SINK WHERE APPLICABLE.

10. EXISTING PLUMBING FIXTURE TO REMAIN AS-IS.

11. PLUMBING IN SHADED AREA TO REMAIN AS-IS.

12. DEMO EXISTING FLOOR SINK. PROPERLY CAP AND SEAL UNUSED PLUMBING PIPE.

1/4" = 1'-0"

1

PLUMBING PLAN - SANITARY_

(EX) FS

(EX) FS

(EX) FS

FS-1

K1401

(EX) FS

3" S

S

(EX) FS

3

1

2" S

S

3

1

2" S

S

3

1

2" S

S

3

1

3" G

W

3

4

2" GW

FS-1

3" GW

T0602

GR-1

2

T0211

T0901

FS-1

3" GW

333

444

8

UC

O

6

7

9

9

9

9

9

10

10

5

1-1/2" C

11

11

11

11

11

11

11

12

12

12

(EX) FS

9

(EX) FS

9

FS-1

2" S

S

3

1

FS-1

3" G

W

3

4

12

/2

2/2

01

7 4

:1

2:3

3 P

M

SEAL

DESCRIPTIONDATEREV.

ISSUE DATE: 3/17/2020

PROJECT NUMBER: 2019-16

DRAWN BY: DW

CHECKED BY: AH

SHEET NAME

SHEET NUMBER

SITE NUMBER:

BASE MDL:

OWNER:

BASE VERSION:

DRAWING RELEASE

PROJECT YEAR:

ASSET TYPE:

CLASSIFICATION:

UPGRADE CLASSIFICATION:

FURNITURE PACKAGE:

2401 S

OU

TH

M

AIN

S

TR

EE

T

PE

RR

YT

ON

, T

EX

AS

, 79070

PROJECT TYPE:

12245

REMODEL E2000

FRANCHISEE

CONVERSION

TOOT N TOTUM

2019 FALL

CONVERSION

2020

UM BRIGHT

SPRING 2020

CONVERSION

REMODEL E2000

10755 SANDHILL ROAD

DALLAS, TEXAS 75238

O: 214-343-9400

dimensiongrp.com

4.3.2020

PLUMBING PLAN -

SANITARY

P1.1

AutoCAD SHX Text
24x48
AutoCAD SHX Text
21x48
AutoCAD SHX Text
TRASH CAN
AutoCAD SHX Text
24x30
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
21x48
AutoCAD SHX Text
24x42
AutoCAD SHX Text
24x30
AutoCAD SHX Text
24x72
AutoCAD SHX Text
22x48
AutoCAD SHX Text
24x42
AutoCAD SHX Text
18x48
AutoCAD SHX Text
18x48
AutoCAD SHX Text
22x36
AutoCAD SHX Text
22x36
AutoCAD SHX Text
22x48
AutoCAD SHX Text
22x36
AutoCAD SHX Text
NO WORK IN
AutoCAD SHX Text
HATCHED AREA
AutoCAD SHX Text
1 04.03.2020 ADDENDUM
AutoCAD SHX Text
1
Page 8: E hD EK X KEFrozen Bun Alt. Existing Dumpster location (dumpsters accessed from alley) 11 AS3.1 9 AS3.1 10 AS3.1 EX. BOLLARD @ DUW TO REMAIN PICK-UP WINDOW R R CONVERSION REMODEL E2000

PANEL B

*SHUNT-TRIP BREAKER CONTROLLED

BY ANSUL SYSTEM. SHUTDOWN OF

POWER ON LOAD SIDE OF BREAKER

SHALL OCCUR ON ACTIVATION OF FIRE

SUPPRESSION SYSTEM OR UPON

MOMENTARY CONTACT OF

ELECTRICAL SHUT DOWN SWITCH "W"

SUB FEEDERS TO PANELS "A", "B", "C"

AND "COOKCENTER" ARE PREWIRED

AND PREINSTALLED INSIDE THE

MODULAR PANEL SYSTEM.

GND. 3/0

AWG, CU.

1

200/3

6

200/3*

SHUNT

TRIP

5

225/3*

SHUNT

TRIP

3/0 AWG, CU.

PANEL A

MDP

208/120V, 3

PHASE, 4 WIRE

65K AIC

PANEL

COOKCENTER*

MAIN WATER

SERVICE PIPE

C.T.

METER

400A. BUS

2

200/3

WEATHERPROOF

C/T CABINET WITH

4OOA C/T.

PANEL C *

LOCAL POWER COMPANY

ELECTRIC METER. VERIFY EXACT

CONFIGURATION WITH POWER

COMPANY PRIOR TO BID

NEUT.

ISOLATED GROUND

2/0 AWG, CU.

BUILDING FOOTER STEEL

2/0 AWG, CU.

#6 AWG, CU.

10'-0" COPPER

CLAD GND. ROD

VOLTS DETERMINED BY UTILITY

COMPANY, KVA DETERMINED BY UTILITY

COMPANY 208/120V, 3 PHASE, 4 WIRE

4#600 & 1#3GND IN 4"

ELECTRICAL DISTRIBUTION GENERAL NOTES

1. PANELS "A", "B" , "C" AND "COOKCENTER" SHALL BE CIRCUITED AS SHOWN.

2. THERMOSTATS TO BE PROVIDED WITH "FC/LC" FAN CONTROL/LIGHTING CONTROL PANEL ALONG WITH REMOTE SENSORS.

3. SYSTEM IS DESIGNED TO FORCE EXHAUST FANS ON WHEN ANSUL SYSTEM ACTIVATES TO MEET CODE REQUIREMENTS.

PRE-PACKAGED,

PRE-WIRED

SWITCHGEAR MODULAR

PANEL SYSTEM

SCALE

1

NEUTRAL

SHUNT

TRIP

BREAKERS

IN 'MDP'

RED

BLACK

CIRCUIT

A-5

MICRO SWITCH

IN HOOD

POWER KILL

SWITCHES

NOT TO SCALE

SHUNT TRIP CIRCUIT DETAIL

2

SERIES RATED NOTES

MAIN BREAKERS IN MDP TO BE "FULLY" RATED TO WITHSTAND THE AVAILABLE

FAULT CURRENT AT M.D.P. OF 65,000 AMPS R.M.S.

2. THE DISTRIBUTION SYSTEM IS TO BE A "SERIES" RATED, TWO-TIER, 65/10 SYSTEM.

3. MOTOR LOAD CONTRIBUTION TO THESE PANELBOARDS SHALL NOT EXCEED 1.0%

OF THE PANELBOARD A.I.C. RATING.

4. WHERE "SERIES" RATING IS USED, PANELBOARDS AND DISTRIBUTION PANELS ARE

TO BE LEGIBLY MARKED TO INDICATE THE EQUIPMENT HAS BEEN APPLIED WITH A

"SERIES" COMBINATION RATING. LABELS CAN BE FACTORY INSTALLED OR

ENGRAVED PLASTIC-LAMINATE CARD. MARKING SHALL COMPLY WITH ARTICLE

110-22 OF N.E.C.

CONTROL ZONES

ZONE 1 KITCHEN LIGHTS & WORK LIGHTS

ZONE 2 DINING ROOM - GENERAL LIGHTS

ZONE 3 HOODS

ZONE 4 PARKING LOT LIGHTS

ZONE 5 EXTERIOR BUILDING LIGHTS/ BUILDING SIGNS/ MENU BOARDS

ZONE 6 NOT USED

ZONE 7 NOT USED

*SEE SHEET W1.1 FOR LIGHT ZONE CONTROL INFORMATION.

ARC FLASH LABELING

A. SWITCHBOARDS, PANELBOARDS AND BUSWAY SHALL HAVE A COMMERCIALLY

PRODUCED PERMANENT LABEL APPLIED, SIMILAR TO IMAGE BELOW, TO WARN OF

POTENTIAL ARC FLASH HAZARDS IN ACCORDANCE WITH NEC 110.16 AND NFPA 70E

B. LABELING MAY BE COMPLETED BY THE CONTRACTOR. THE CONTRACTOR SHALL

VERIFY THAT SWITCHBOARDS AND PANELBOARDS ARE PROPERLY LABELED IN THE

FIELD.

C. PROVIDE AND INSTALL A LABEL SIMILAR TO BELOW TO COMPLY WITH NEC 110.16

AND NFPA 70E. THE MARKING SHALL BE LOCATED SO AS TO BE CLEARLY TO

QUALIFIED PERSONS BEFORE EXAMINATION, ADJUSTMENT, SERVICING OR

MAINTENANCE OF THE EQUIPMENT. LABEL SHALL NOT BE LOCATED ON A HINGED

DOOR, OR A MOVABLE SERVICE.

CONTRACTOR TO ORDER ELECTRICAL PANEL

SYSTEM AT THE START OF CONSTRUCTION

GIVEN THE 6 WEEK LEAD TIME FOR THE

MODULAR PANEL SYSTEM. CONTRACTOR TO

PROVIDE MECHANICAL AND ELECTRICAL PLANS

WHEN PLACING ORDER.

CONTACT SUPPLIER FOR

SEISMIC BRACING.

'COOK-

PANEL

PANEL

'B'

PANEL

'C'

PANEL

'MDP' .

'IFS-SLK'

'FC/LC' FAN

CONTROL/

LIGHTING

CONTROL

PANEL

'A'

EXTERIOR WALL

POWER COMPANY

METER

WP C/T EQUIPMENT

CABINET

REFER TO SHEET W1.1

FOR MORE INFORMATION

ON 'FCLC'

SURGE PROTECTION

DEVICE

CENTER'

SEE ARCHITECTURAL

SHEETS FOR CURB AT

SWITCHGEAR

3

SCALE

SPD

NOTE:

CONTRACTOR TO DOWNLOAD AND EXECUTE

MODULAR PANEL SYSTEM'S START UP AND

SYSTEM CHECK LIST REQUIREMENTS FROM

WENDY'S.

DISCONNECT

4#600 & 1#3GND IN 4"

ELECTRICAL ONE-LINE DIAGRAMELECTRICAL DISTRIBUTION ELEVATION (WESCO)

SEAL

DESCRIPTIONDATEREV.

ISSUE DATE: 3/17/2020

PROJECT NUMBER: 2019-16

DRAWN BY: DW

CHECKED BY: AH

SHEET NAME

SHEET NUMBER

SITE NUMBER:

BASE MDL:

OWNER:

BASE VERSION:

DRAWING RELEASE

PROJECT YEAR:

ASSET TYPE:

CLASSIFICATION:

UPGRADE CLASSIFICATION:

FURNITURE PACKAGE:

2401 S

OU

TH

M

AIN

S

TR

EE

T

PE

RR

YT

ON

, T

EX

AS

, 79070

PROJECT TYPE:

12245

REMODEL E2000

FRANCHISEE

CONVERSION

TOOT N TOTUM

2019 FALL

CONVERSION

2020

UM BRIGHT

SPRING 2020

CONVERSION

REMODEL E2000

10755 SANDHILL ROAD

DALLAS, TEXAS 75238

O: 214-343-9400

dimensiongrp.com

4.3.2020

ELECTRIC DISTRIBUTION

(GAS HEAT/GAS COOKING)

E3.1

AutoCAD SHX Text
1.MAIN BREAKERS IN MDP TO BE "FULLY" RATED TO WITHSTAND THE AVAILABLE
AutoCAD SHX Text
1
AutoCAD SHX Text
1 04.03.2020 ADDENDUM