E-1 - Clarke Contracting, LLCclarkecontracting.biz/Projects/Dollar General/Plans/Dollar...

8
SODA COOLER SODA COOLER ICE CREAM FREEZER GATOR ADE A/4 A/8 BUZZER A/4 BUZZER PUSH BUTTON BRING RIGID PIPE SLEEVE THROUGH BUILDING TO ALLOW PHONE LINE PENETRATION. SEAL ALL PENETRATIONS. POWER FOR IRRIGATION CONTROL BOX. COORDINATE EXACT POWER REQUIREMENTS PRIOR TO ROUGH-IN. ELECTRIC METER BY UTILITY CO. REFER TO 1/E-5 FOR SERVICE DETAILS A/33 1 B/8 B/8 B/8 AUTOMATIC DOOR A/2 A/26 3529,'( 9 $ 121 FUSED DISC. AT RESTROOM WATER HEATER CKT. A/29,31 2#10, 1#10G, 3/4"C GFCI PROVIDE 1 POLE TOGGLE SWITCH AT EXHAUST FAN CEILING MOUNTED EXHAUST FAN EF-2. MOTION SENSOR CONTROLLED. CKT. A/16 CEILING MOUNTED EXHAUST FAN EF-1. MOTION SENSOR CONTROLLED. CKT. A/14 PROVIDE 1 POLE TOGGLE SWITCH AT EXHAUST FAN COORDINATE THE FINAL LOCATION AND AMOUNT OF REGISTERS WITH THE APPROVED FIXTURE PLAN. EF-1 EF-2 MOUNT RECEPTACLE WITHIN 18" OF TOP OF WINDOW A/30 DEDICATED, WP, GFCI RECESSED @ 4' A.F.F. 4'-0" DEDICATED, WP, GFCI, 20 AMP OUTLET RECESSED @ 4' A.F.F. FOR ICE MERCHANDISER 4'-0" A/10 A/12 3529,'( 9 $ 121 FUSED DISC. AT RECEIVING AREA WATER HEATER EWH-1 CKT. A/25,27 2#10, 1#10G, 3/4"C AUTOMATIC DOOR A/28 A/34,36 2#10, 1#10GND. IN 3/4" CONDUIT FOR CEILING MOUNTED VESTIBULE CABINET UNIT HEATER. PROVIDE 30A NON-FUSED DISCONNECT SWITCH. REFER TO SHEETS E3.2 FOR WIRING INFORMATION. (B/30,32,34,36,38,40) 4 E1 NOTE: CONFIRM LOCATION OF ALL POWER POLES WITH FIXTURE PLAN. SEE SHEET E-3.1 FOR ADDITIONAL INFORMATION. 2 E1 3 E1 GATORADE COOLER @4'-0" A.F.F.CKT B/28 RIGID CONDUIT ANCHOR TO PURLINS ABOVE. (TYP OF 4) ICE CREAM FREEZER CKT. B/26 TERMINATE @ 78"AFF SODA COOLER CKT. B/24 TERMINATE @ 78"AFF SODA COOLER CKT. B/22 TERMINATE @ 78"AFF DRINK COOLER CKT. B/20 TERMINATE @ 48"AFF RTU-1 RTU-2 RTU-3 RTU-4 2 TYP A/24 GFCI WP CKT. A/7,9,11 4 TYP 6 TYP A/24 GFCI WP CKT. A/1,3,5 RTU-4 CKT. A/19,21,23 A/24 GFCI WP A/24 GFCI WP WOMENS 105 VESTIBULE 107 MENS 104 OFFICE 101 BREAK ROOM 100 HALLWAY 106 SALES AREA 102 RECIEVING AREA 103 PROVIDE 240V, 30A FUSED H.D. DISC. SWITCH IN NEMA 3R ENCLOSURE FOR WELL PUMP. 1" PVC SCH. 40 UNDERGROUND CONDUIT. CIRCUIT SHALL BE (2)#12, (1)#12 GND. (CKT. B/55,57) 3803 +3 9 B/59 B/59 WATER WELL EQUIPMENT. SEE NOTE 19. SEE SPECIFICATION #18. LOCATED ALL CONDUIT TO OFFICE IN THIS WALL. B/6 A/20 B/4 B/6 A/18 A/22 B/6 DEDICATED QUAD RECEPT. @6'-0" FOR VSAT, D-LINK EQUIP ON PLYWOOD BACKBOARD. DED. DUPLEX RECEPT @48" FOR INTERFACE ON PLYWOOD BACKBOARD. SECURITY OUTLET AT 7'-0" AFF DEDICATED QUAD RECEPT @3'-0" FOR CCTV EQUIP. DEDICATED QUAD RECEPT @3'-0" . 1/A-4 BEFORE ORDERING AND INSTALLATION OF ELECTRICAL COMPONENTS FOR FREEZERS AND COOLERS, CONSULT FINAL FIXTURE PLAN FOR NUMBER AND LOCATION. MAXIMUM CIRCUITS FOR COOLERS/FREEZERS - (5) 120V AND (3) 208V. S030 - FREEZER POWER POLE. REFER TO SHEET E3.1. S020 - FREEZER/ COOLER POWER POLE. REFER TO SHEET E3.1. S019 - COOLER POWER POLE. REFER TO SHEET E3.1. NOTE: 1. MINIMUM WIRE SIZE TO BE #8 FOR ALL COOLERS & FREEZERS. 2. REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS. B/37,39 B/41,43 B/45,47 B/46 B/48 B/50 B/52 B/54 1 2 3 4 5 B A JOB NO. D C ISSUED FOR: PERMIT RECORD CONSTRUCTION BID 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 FAX 330.572.2101 2016408.03 DOLLAR GENERAL N.J. STATE ROUTE 54 & ROUTE 73 FOLSOM (HAMMONTON), NJ 08037 11.04.16 03.29.17 - - DATE DESCRIPTION Drawing Name: O:\2016\2016408\03 Folsom, NJ\Dwg\Bldg\700_E1_POWER PLAN.DWG March 29, 2017 - akolesar E-1 POWER PLAN MAR WCF 1/8" = 1'-0" E-1 1 POWER PLAN 2 ELECTRICAL PANEL ELEVATION 3/4" = 1'-0" E-1 125V NEMA 5-20R QUAD. A/23 PANEL/CIRCUIT IN PANEL S 20 AMP TOGGLE SWITCH NIGHT LIGHT CIRCUIT NL S m PROVIDE OCCUPANCY LIGHT SENSOR- LEVITON ODS10-IDW LEGEND BLACK MAGIC POWER POLE 125V NEMA 5-20R DUPLEX. PANEL/CIRCUIT IN PANEL PHONE JACK @ REGISTER 125/250V NEMA L14-20-R 4 PRONG TWIST LOCK BUZZER - TORK MDL #TA725 W/ TRANSFORMER MDL#TA592 DISCONNECT A/23 VOICE/DATA PORT = RJ-11, RJ-45 DATA JACK, PHONE COMBO @ OFFICE PUSH BUTTON 1. ALL EXPOSED WIRING SHALL BE CONTAINED IN CONDUIT SIZED PER THE N.E.C. 2. BELOW GRADE AND IN SLAB: PVC SCHEDULE 40. 3. ABOVE GRADE OUTDOORS: PVC SCHEDULE 80. 4. ABOVE GRADE INDOORS: EMT, RGS IF EMT CAN BE DAMAGED. MC CABLE WITH CU GREEN CODE SIZE GROUND INSIDE WALLS AND ABOVE CEILINGS ONLY, IF APPROVED BY BOTH THE OWNER AND LOCAL JURISDICTION. ALL BOXES AND DEVICES SHALL BE BONDED TO THE GROUND CONDUCTOR. 5. ALL WIRING SHALL CONFORM TO LOCAL, STATE, AND FEDERAL CODES. 6. SERVICE SHALL BE MINIMUM 400 AMP, 208V-3 PHASE, 600 AMP, 240V-1 PHASE, OR LARGER IF REQUIRED BY CODE OR ELECTRICAL LOAD. SEE ONE-LINE. 7. REQUIRED CUSTOM BUILT POWER POLE ASSEMBLIES AVAILABLE FROM D&P CUSTOM LIGHTS & PRODUCTS INC., PHONE: (800) 251-2200 OR (615) 350-7800, 7111 COCKRILL BEND INDUSTRIAL ROAD, NASHVILLE, TN 37209. SEE E3.1. 8. EXTERIOR EXPOSED PHONE LINES SHALL BE INSTALLED IN RIDGED CONDUIT. PROVIDE EMERSON 3/4" X 5-FT. METALLIC CABLE U-GUARD #755, OR EQUAL. 9. ELECTRICAL PANEL SHALL BE LABELED CORRECTLY AND WITH LEGIBLE PRINT. 10.PROVIDE SHORT CIRCUIT CALC. & LABELS. PROVIDE ARC FLASH STUDY & LABELS. 11.PROVIDE 4" EMT CONDUIT WITH PULL STRING TO ACT AS ACCESS SLEEVE TO ALLOW PHONE COMPANY TO TERMINATE AT DMARC. CONTRACTOR TO PROVIDE & INSTALL PHONE WIRING & RJ-11 PHONE JACK FOR A COMPLETED WORKING SYSTEM PRIOR TO PHONE COMPANY FINAL HOOK-UP. 12. ALL 120 VOLT OUTDOOR RECEPTACLES SHALL HAVE "WET LOCATION - IN USE" WEATHERPROOF COVERS. 13. ALL CONDUCTORS TO BE COPPER, #12 AWG MINIMUM SIZE, OR SIZE AS REQUIRED BY LOAD AND OVER CURRENT PROTECTION. 14. SEE EMS SHEETS EMS-1 & EMS-2 FOR ENERGY MANAGEMENT SYMBOLS AND INFORMATION. 15.ELECTRICIAN SHALL PROVIDE 1 1 2 " CONDUIT WITH PULL STRING FOR SATELLITE LINE. REFER TO 4/A-3 FOR LOCATION. 16. G.C. SHALL INSTALL A KNOX BOX IN LOCATION SELECTED BY LOCAL FIRE CODE AUTHORITY PER LOCAL JURISDICTION REQUIREMENTS. KNOX BOX SHALL BE FLUSH OR SURFACE MOUNTED. 17. ALL POWER AND DATA TO BE ROUTED OVERHEAD. UNDER SLAB NOT ALLOWED. 18.LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL ONE (1) 24 GA., 4 TWISTED-PAIR, CATEGORY-FIVE (CAT5) DATA CABLE WITH MODULAR COMBO RJ-11/RJ-45 JACK AT MANAGER'S OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB LOCATION WITH 6'-0" LEFT COILED FOR INSTALLATION TO DATA HUB. A RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END. DOLLAR GENERAL STORE OPENING TEAM WILL MAKE FINAL CONNECTION INTO THE DATA HUB. 19.E.C. SHALL PROVIDE RECEPTACLES WIRED TO CIRCUIT B-59 (20/1) FOR WATER WELL EQUIPMENT (FILTER AND SOFTENER). COORDINATE EXACT POWER REQUIREMENTS AND LOCATION WITH MANUFACTURER/INSTALLER PRIOR TO ROUGH-IN . 1. TEST/RESET STATION FOR STAND ALONE DUCT DETECTOR. ONE FOR EACH DEVICE, SEE KEY NOTE 3 ON THIS SHEET. SYSTEM SENSOR IS SPECIFIED WITH REMOTE TEST STATION MODEL RTS2. 2. MECHANICAL THERMOSTAT AT 8'-0" A.F.F. 3. LOCATIONS SHOWN FOR MECHANICAL UNITS ARE ONLY APPROXIMATE, CONTRACTOR MUST CONSULT MECHANICAL OR STRUCTURAL DRAWINGS TO DETERMINE ACTUAL UNIT LOCATIONS. PROVIDE 1/2"C. PENETRATION THRU ROOF WITHIN FOOTPRINT OF UNIT FOR USE WITH CONTROL WIRING TO UNIT BY OTHERS. PROVIDE PROPER WATERSEAL. (TYPICAL) 4. FACTORY MOUNTED NON-POWERED CONVENIENCE OUTLET PROVIDED WITH UNIT. WIRE TO CIRCUIT INDICATED. 5. PHOTOELECTRIC DUCT DETECTOR WITH HOUSING. TIE TO LED READOUT RECESSED IN CEILING. STAND ALONE DEVICE, 120V. SYSTEM SENSOR #D4120 IS SPECIFIED WITH #RTS2 CONTROL STATION. PROVIDE ONE DEVICE PER UNIT. MOUNT DEVICE IN SUPPLY AIR DUCTWORK. DEVICE SHALL BE PROVIDED AND WIRED TO THE CONTROL STATION BY THE ELECTRICAL CONTRACTOR. HIRE THE MECHANICAL CONTRACTOR FOR INSTALLATION IN DUCTWORK & CONNECTION TO SHUTDOWN CONTROLS. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED RELAYS AND 120V POWER, DO NOT POWER DUCT DETECTORS FROM HVAC UNIT LOW VOLTAGE . SUBMIT SHOP DRAWINGS FOR APPROVAL. PLACE ANY REQUIRED LABELING ON CEILING TILE DIRECTLY BELOW UNIT. RUN CONDUIT & WIRE UNDERGROUND FROM UNIT TO INSIDE OF SPACE. 6. MOUNT DISCONNECT SWITCH AT UNIT. ALL DISCONNECTS TO BE HEAVY DUTY. FUSES TO BE RK-5 TYPE, BUSSMANN FRN-R-(AMP) IS SPECIFIED. ALL WIRING SHALL BE CONTAINED IN CONDUIT OF PROPER SIZE PER N.E.C. ELECTRICAL KEYED NOTES # 4 COOLER/FREEZER RECEPTACLE LAYOUT N.T.S E-1 6'-4" DMARC PANEL A PANEL B 3/4" PLYWOOD 8' WIDE X 5'-5" HIGH, FIRE RATED, NO VOIDS, PAINTED WHITE UNLESS CODE DICTATES OTHERWISE. FLOOR LINE DUPLEX RECEPTACLE DEDICATE CIRCUIT TELEPHONE CONDUIT STUB THROUGH WALL. SEE ELECTRICAL SPECIFICATION NOTE #8 AND #11. EMS A/6 1'-1" 5" 5" 1'-8" 1'-8" 1'-8" 1'-1" 8'-0" 3 LARGE SCALE OFFICE PLAN N.T.S E-1 ELECTRICAL SPECIFICATIONS:

Transcript of E-1 - Clarke Contracting, LLCclarkecontracting.biz/Projects/Dollar General/Plans/Dollar...

SO

DA

CO

OL

ER

SODA

COOLER

IC

E C

RE

AM

FR

EE

ZE

R

GATOR

ADE

A/4

A/8

BUZZER

A/4

BUZZER

PUSH BUTTON

BRING RIGID PIPE

SLEEVE THROUGH

BUILDING TO

ALLOW PHONE

LINE

PENETRATION.

SEAL ALL

PENETRATIONS.

POWER FOR

IRRIGATION

CONTROL BOX.

COORDINATE EXACT

POWER

REQUIREMENTS

PRIOR TO ROUGH-IN.

ELECTRIC METER

BY UTILITY CO.

REFER TO 1/E-5

FOR SERVICE

DETAILS

A/33

1

B/8

B/8

B/8

AUTOMATIC DOOR A/2

A/26

PROVIDE 240V/1Ø, 30A NON

FUSED DISC. AT RESTROOM

WATER HEATER CKT. A/29,31

2#10, 1#10G, 3/4"C

GFCI

PROVIDE 1 POLE TOGGLE

SWITCH AT EXHAUST FAN

CEILING MOUNTED

EXHAUST FAN EF-2.

MOTION SENSOR

CONTROLLED.

CKT. A/16

CEILING MOUNTED EXHAUST

FAN EF-1. MOTION SENSOR

CONTROLLED. CKT. A/14

PROVIDE 1 POLE TOGGLE

SWITCH AT EXHAUST FAN

COORDINATE THE FINAL LOCATION

AND AMOUNT OF REGISTERS WITH

THE APPROVED FIXTURE PLAN.

EF-1

EF-2

MOUNT RECEPTACLE WITHIN

18" OF TOP OF WINDOW

A/30

DEDICATED, WP, GFCI

RECESSED @ 4' A.F.F.

4'-0

"

DEDICATED, WP, GFCI, 20 AMP

OUTLET RECESSED @ 4' A.F.F.

FOR ICE MERCHANDISER

4'-0

"

A/10

A/12

PROVIDE 240V/1Ø, 30A NON

FUSED DISC. AT RECEIVING

AREA WATER HEATER EWH-1

CKT. A/25,27

2#10, 1#10G, 3/4"C

AUTOMATIC DOOR A/28

A/34,36

2#10, 1#10GND. IN 3/4" CONDUIT

FOR CEILING MOUNTED

VESTIBULE CABINET UNIT HEATER.

PROVIDE 30A NON-FUSED

DISCONNECT SWITCH.

REFER TO SHEETS E3.2 FOR

WIRING INFORMATION.

(B/30,32,34,36,38,40)

4

E1

NOTE:

CONFIRM LOCATION OF ALL POWER

POLES WITH FIXTURE PLAN.

SEE SHEET E-3.1 FOR

ADDITIONAL INFORMATION.

2

E1

3

E1

GATORADE COOLER

@4'-0" A.F.F.CKT

B/28

RIGID CONDUIT ANCHOR

TO PURLINS ABOVE.

(TYP OF 4)

ICE CREAM FREEZER

CKT. B/26

TERMINATE @ 78"AFF

SODA COOLER

CKT. B/24

TERMINATE @ 78"AFF

SODA COOLER

CKT. B/22

TERMINATE @ 78"AFF

DRINK COOLER CKT. B/20

TERMINATE @ 48"AFF

RTU-1

RTU-2

RTU-3

RTU-4

2

TYP

A/24

GFCI WP

CKT.

A/7,9,11 4

TYP

6

TYP

A/24

GFCI WP

CKT.

A/1,3,5

RTU-4

CKT.

A/19,21,23 A/24

GFCI WP

A/24 GFCI WP

WOMENS

105

VESTIBULE

107

MENS

104

OFFICE

101

BREAK ROOM

100

HALLWAY

106

SALES AREA

102

RECIEVING AREA

103

PROVIDE 240V, 30A FUSED H.D. DISC. SWITCH IN NEMA 3R

ENCLOSURE FOR WELL PUMP.

1" PVC SCH. 40 UNDERGROUND CONDUIT. CIRCUIT SHALL BE

(2)#12, (1)#12 GND. (CKT. B/55,57)

PUMP, 1HP, 240V, 1Ø.

B/59

B/59

WATER WELL

EQUIPMENT.

SEE NOTE 19.

SEE

SPECIFICATION

#18.

LOCATED ALL CONDUIT TO

OFFICE IN THIS WALL.

B/6

A/20

B/4

B/6

A/18

A/22

B/6

DEDICATED QUAD

RECEPT. @6'-0" FOR

VSAT, D-LINK EQUIP ON

PLYWOOD BACKBOARD.

DED. DUPLEX RECEPT

@48" FOR INTERFACE ON

PLYWOOD BACKBOARD.

SECURITY OUTLET

AT 7'-0" AFF

DEDICATED

QUAD

RECEPT

@3'-0" FOR

CCTV EQUIP.

DEDICATED

QUAD

RECEPT

@3'-0" .

1/A-4

BEFORE ORDERING AND INSTALLATION OF ELECTRICAL COMPONENTS FOR

FREEZERS AND COOLERS, CONSULT FINAL FIXTURE PLAN FOR NUMBER AND LOCATION.

MAXIMUM CIRCUITS FOR COOLERS/FREEZERS - (5) 120V AND (3) 208V.

S030 - FREEZER

POWER POLE.

REFER TO

SHEET E3.1.

S020 - FREEZER/ COOLER

POWER POLE.

REFER TO SHEET E3.1.

S019 - COOLER

POWER POLE.

REFER TO SHEET E3.1.

NOTE:

1. MINIMUM WIRE SIZE TO BE #8 FOR ALL COOLERS & FREEZERS.

2. REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS.

B/37,39

B/41,43

B/45,47

B/46

B/48

B/50

B/52

B/54

1 2 3 4 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RECORD

CONSTRUCTION

BID

520 South Main Street, Suite 2531

Akron, OH 44311

330.572.2100 FAX 330.572.2101

2016408.03

DO

LL

AR

G

EN

ER

AL

N.J. S

TA

TE

R

OU

TE

54 &

R

OU

TE

73

FO

LS

OM

(H

AM

MO

NT

ON

), N

J 08037

11.04.16

03.29.17

-

-

DA

TE

DE

SC

RIP

TIO

N

Dra

win

g N

am

e: O

:\2

01

6\2

01

64

08

\0

3 F

olso

m, N

J\D

wg

\B

ld

g\7

00

_E

1_

PO

WE

R P

LA

N.D

WG

Ma

rch

2

9, 2

01

7 - a

ko

le

sa

r

E-1

PO

WE

R P

LA

N

MAR WCF

1/8" = 1'-0"

E-1

1 POWER PLAN

2 ELECTRICAL PANEL ELEVATION

3/4" = 1'-0"

E-1

125V NEMA 5-20R QUAD.

A/23

PANEL/CIRCUIT IN PANEL

S

20 AMP TOGGLE SWITCH

NIGHT LIGHT CIRCUITNL

S

m

PROVIDE OCCUPANCY LIGHT

SENSOR- LEVITON ODS10-IDW

LEGEND

BLACK MAGIC POWER POLE

125V NEMA 5-20R DUPLEX.

PANEL/CIRCUIT IN PANEL

PHONE JACK @ REGISTER

125/250V NEMA L14-20-R

4 PRONG TWIST LOCK

BUZZER - TORK MDL #TA725 W/

TRANSFORMER MDL#TA592

DISCONNECT

A/23

VOICE/DATA PORT = RJ-11,

RJ-45 DATA JACK, PHONE

COMBO @ OFFICE

PUSH BUTTON

1. ALL EXPOSED WIRING SHALL BE CONTAINED IN CONDUIT SIZED PER THE N.E.C.

2. BELOW GRADE AND IN SLAB: PVC SCHEDULE 40.

3. ABOVE GRADE OUTDOORS: PVC SCHEDULE 80.

4. ABOVE GRADE INDOORS: EMT, RGS IF EMT CAN BE DAMAGED. MC CABLE WITH CU

GREEN CODE SIZE GROUND INSIDE WALLS AND ABOVE CEILINGS ONLY, IF APPROVED

BY BOTH THE OWNER AND LOCAL JURISDICTION. ALL BOXES AND DEVICES SHALL BE

BONDED TO THE GROUND CONDUCTOR.

5. ALL WIRING SHALL CONFORM TO LOCAL, STATE, AND FEDERAL CODES.

6. SERVICE SHALL BE MINIMUM 400 AMP, 208V-3 PHASE, 600 AMP, 240V-1 PHASE, OR

LARGER IF REQUIRED BY CODE OR ELECTRICAL LOAD. SEE ONE-LINE.

7. REQUIRED CUSTOM BUILT POWER POLE ASSEMBLIES AVAILABLE FROM D&P CUSTOM

LIGHTS & PRODUCTS INC., PHONE: (800) 251-2200 OR (615) 350-7800, 7111 COCKRILL BEND

INDUSTRIAL ROAD, NASHVILLE, TN 37209. SEE E3.1.

8. EXTERIOR EXPOSED PHONE LINES SHALL BE INSTALLED IN RIDGED CONDUIT. PROVIDE

EMERSON 3/4" X 5-FT. METALLIC CABLE U-GUARD #755, OR EQUAL.

9. ELECTRICAL PANEL SHALL BE LABELED CORRECTLY AND WITH LEGIBLE PRINT.

10.PROVIDE SHORT CIRCUIT CALC. & LABELS. PROVIDE ARC FLASH STUDY & LABELS.

11.PROVIDE 4" EMT CONDUIT WITH PULL STRING TO ACT AS ACCESS SLEEVE TO ALLOW

PHONE COMPANY TO TERMINATE AT DMARC. CONTRACTOR TO PROVIDE & INSTALL

PHONE WIRING & RJ-11 PHONE JACK FOR A COMPLETED WORKING SYSTEM PRIOR TO

PHONE COMPANY FINAL HOOK-UP.

12. ALL 120 VOLT OUTDOOR RECEPTACLES SHALL HAVE "WET LOCATION - IN USE"

WEATHERPROOF COVERS.

13. ALL CONDUCTORS TO BE COPPER, #12 AWG MINIMUM SIZE, OR SIZE AS REQUIRED BY

LOAD AND OVER CURRENT PROTECTION.

14.SEE EMS SHEETS EMS-1 & EMS-2 FOR ENERGY MANAGEMENT SYMBOLS AND

INFORMATION.

15.ELECTRICIAN SHALL PROVIDE 1

1

2

" CONDUIT WITH PULL STRING FOR SATELLITE LINE.

REFER TO 4/A-3 FOR LOCATION.

16.G.C. SHALL INSTALL A KNOX BOX IN LOCATION SELECTED BY LOCAL FIRE CODE

AUTHORITY PER LOCAL JURISDICTION REQUIREMENTS. KNOX BOX SHALL BE FLUSH OR

SURFACE MOUNTED.

17. ALL POWER AND DATA TO BE ROUTED OVERHEAD. UNDER SLAB NOT ALLOWED.

18.LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL ONE (1) 24 GA., 4 TWISTED-PAIR,

CATEGORY-FIVE (CAT5) DATA CABLE WITH MODULAR COMBO RJ-11/RJ-45 JACK AT

MANAGER'S OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB LOCATION WITH 6'-0"

LEFT COILED FOR INSTALLATION TO DATA HUB. A RJ-45 MALE FITTING SHOULD BE

CRIMPED ON THIS END. DOLLAR GENERAL STORE OPENING TEAM WILL MAKE FINAL

CONNECTION INTO THE DATA HUB.

19.E.C. SHALL PROVIDE RECEPTACLES WIRED TO CIRCUIT B-59 (20/1) FOR WATER WELL

EQUIPMENT (FILTER AND SOFTENER). COORDINATE EXACT POWER REQUIREMENTS AND

LOCATION WITH MANUFACTURER/INSTALLER PRIOR TO ROUGH-IN .

1. TEST/RESET STATION FOR STAND ALONE DUCT

DETECTOR. ONE FOR EACH DEVICE, SEE KEY NOTE

3 ON THIS SHEET. SYSTEM SENSOR IS SPECIFIED

WITH REMOTE TEST STATION MODEL RTS2.

2. MECHANICAL THERMOSTAT AT 8'-0" A.F.F.

3. LOCATIONS SHOWN FOR MECHANICAL UNITS ARE

ONLY APPROXIMATE, CONTRACTOR MUST

CONSULT MECHANICAL OR STRUCTURAL

DRAWINGS TO DETERMINE ACTUAL UNIT

LOCATIONS. PROVIDE 1/2"C. PENETRATION THRU

ROOF WITHIN FOOTPRINT OF UNIT FOR USE WITH

CONTROL WIRING TO UNIT BY OTHERS. PROVIDE

PROPER WATERSEAL. (TYPICAL)

4. FACTORY MOUNTED NON-POWERED CONVENIENCE

OUTLET PROVIDED WITH UNIT. WIRE TO CIRCUIT

INDICATED.

5. PHOTOELECTRIC DUCT DETECTOR WITH HOUSING.

TIE TO LED READOUT RECESSED IN CEILING.

STAND ALONE DEVICE, 120V. SYSTEM SENSOR

#D4120 IS SPECIFIED WITH #RTS2 CONTROL

STATION. PROVIDE ONE DEVICE PER UNIT. MOUNT

DEVICE IN SUPPLY AIR DUCTWORK. DEVICE SHALL

BE PROVIDED AND WIRED TO THE CONTROL

STATION BY THE ELECTRICAL CONTRACTOR. HIRE

THE MECHANICAL CONTRACTOR FOR

INSTALLATION IN DUCTWORK & CONNECTION TO

SHUTDOWN CONTROLS. ELECTRICAL

CONTRACTOR SHALL PROVIDE ALL REQUIRED

RELAYS AND 120V POWER, DO NOT POWER DUCT

DETECTORS FROM HVAC UNIT LOW VOLTAGE .

SUBMIT SHOP DRAWINGS FOR APPROVAL. PLACE

ANY REQUIRED LABELING ON CEILING TILE

DIRECTLY BELOW UNIT. RUN CONDUIT & WIRE

UNDERGROUND FROM UNIT TO INSIDE OF SPACE.

6. MOUNT DISCONNECT SWITCH AT UNIT. ALL

DISCONNECTS TO BE HEAVY DUTY. FUSES TO BE

RK-5 TYPE, BUSSMANN FRN-R-(AMP) IS SPECIFIED.

ALL WIRING SHALL BE CONTAINED IN CONDUIT OF

PROPER SIZE PER N.E.C.

ELECTRICAL

KEYED NOTES

#

4 COOLER/FREEZER RECEPTACLE LAYOUT

N.T.S

E-1

6'-4"

DMARC

PANEL

A

PANEL

B

3/4" PLYWOOD 8' WIDE X 5'-5" HIGH, FIRE

RATED, NO VOIDS, PAINTED WHITE

UNLESS CODE DICTATES OTHERWISE.

FLOOR LINE

DUPLEX RECEPTACLE

DEDICATE CIRCUIT

TELEPHONE CONDUIT STUB

THROUGH WALL. SEE ELECTRICAL

SPECIFICATION NOTE #8 AND #11.

EMS

A/6

1'-1" 5" 5"1'-8" 1'-8"

1'-8"1'-1"

8'-0"

3 LARGE SCALE OFFICE PLAN

N.T.S

E-1

ELECTRICAL SPECIFICATIONS:

B/16

B/5

B/17

F F F F F F F F

F

F

F

F

F

F

F

F

F

F

F

F

F F

F

F F

F

F F

F

F

F

F

F

FF

F

F

F

FF

FF

F

FF

F

F

F

FF

F

F

F

F

F

F

F

F

F F

F

F

F

B/13 B/15 B/11

B/9

B/7

F

NIGHT LIGHT CIRCUIT

LEGEND

EMERGENCY LIGHT

WALL PACK

PANEL/CIRCUIT NO.

A/12

NL

K

EMERGENCY LIGHT

AND EXIT COMBO

K.1

F

J.1

OCCUPANCY LIGHT

SENSOR -LEVITON -

ODS10-IDW

LIGHT FIXTURE TYPE

B

N.1

LIGHT FIXTURE TYPE

F

1 2 3 4 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RECORD

CONSTRUCTION

BID

520 South Main Street, Suite 2531

Akron, OH 44311

330.572.2100 FAX 330.572.2101

2016408.03

DO

LL

AR

G

EN

ER

AL

N.J. S

TA

TE

R

OU

TE

54 &

R

OU

TE

73

FO

LS

OM

(H

AM

MO

NT

ON

), N

J 08037

11.04.16

03.29.17

-

-

DA

TE

DE

SC

RIP

TIO

N

Dra

win

g N

am

e: O

:\2

01

6\2

01

64

08

\0

3 F

olso

m, N

J\D

wg

\B

ld

g\7

10

_E

2_

LIG

HT

IN

G P

LA

N.d

wg

---- - a

ko

le

sa

r

E-2

LIG

HT

IN

G P

LA

N

MAR WCF

1/8" = 1'-0"

E-2

1 LIGHTING PLAN

NOTE: ALL NIGHT LIGHTS, EMERGENCY

LIGHTS, AND EXIT SIGNS SHALL BE

WIRED AHEAD OF ALL LOCAL SWITCHING

TO LIGHTING CIRCUIT INDICATED.

EMERGENCY/EXIT SIGNS AND LIGHTS: INSTALL

EMERGENCY LIGHTS AND EXIT SIGNS (CENTERED AT

10'-6" A.F.F. TO BE ABOVE FIXTURES & MERCHANDISE)

THROUGHOUT THE BLDG. IN COMPLIANCE WITH ALL

APPLICABLE CODES.

COORDINATE BUILDING SIGN SIZE WITH DOLLAR

GENERAL SIGN DEPARTMENT BY EMAILING TO

SIGNAGE@DOLLAR GENERAL.COM, LOCATE JBOX ON

INTERIOR OF PARAPET 13'-0" LEFT OF CENTER OF

SIGNBAND AREA B/23.

1/16" = 1'-0"

E-2

2 CABLE TRAY PLAN AND CONDUIT DIAGRAM

LIGHTING WIRING NOTES

1. AN OCTAGON BOX MOUNTED ON TOP OF EACH FIXTURE,

WITH FIXTURE WIRING BROUGHT INTO THE BOX FOR

CONNECTION TO THE CORD.

2. A TWISTLOCK 20AMP 120 VOLT RECEPTACLE AND CORD

FOR ATTACHMENT AT THE STEEL TRUSS MOUNTED IN A

STEEL BOX DIRECTLY ABOVE EACH LIGHT FIXTURE, EACH

BOX CONNECTED WITH STEEL CONDUITS BETWEEN EACH

OTHER BOX AND A STEEL CONDUIT HOME RUN BACK TO

THE PANEL.

3. THE SHO CORD SHALL BE 2#12 AND #12 GROUND, ALL

COPPER, FED FROM A 20 AMP SINGLE POLE BREAKER. THE

CORD SHALL ONLY BE USED AS A DROP FROM THE

RECEPTACLE BOX AT BUILDING STEEL AND TERMINATE

INTO A STEEL OCTAGON BOX MOUNTED ON TOP OF EACH

FIXTURE. THE CORD WILL HANG STRAIGHT DOWN TO THE

FIXTURE FROM THE RECEPTACLE / MOUNTING BOX, IT

SHALL NOT BE DRAPED HORIZONTALLY ACROSS BUILDING

STEEL BEFORE HANGING DOWN TO THE FIXTURE.

LIGHTING GENERAL NOTES:

1. ALL NIGHT LIGHTS, EMERGENCY LIGHTS, AND

EXIT SIGNS SHALL BE WIRED AHEAD OF ALL

LOCAL SWITCHING TO LIGHTING CIRCUIT

INDICATED.

2. SALES AND RECEIVING LIGHTS TO BE MOUNTED

AT 11'-0" AFF.

3. REFER TO SHEET A-8 FOR LIGHT FIXTURE

ATTACHMENT DETAIL.

4. RECEIVING AREA LIGHTS TO BE SPACED

EVENLY BETWEEN FRONT AND REAR WALL OF

THE RECEIVING AREA.

5. EMERGENCY LIGHT FIXTURE 'K' TO BE MOUNTED

AT 10'-6" AFF, ABOVE SHEETROCK.

1. CABLE TRAY TO BE MOUNTED SUCH THAT

BOTTOM OF TRAY IS AT 11'-6" A.F.F.. REFER TO

ELECTRICAL DRAWINGS FOR ADDITIONAL

INFORMATION.

2. CABLE TRAY SYSTEM TO BE INSTALLED USING

FULL LENGTHS WITH MINIMAL CUTTING OF

SECTIONS. AREAS WHERE CUTTING MAY

REQUIRED ARE AS NOTED ON THE PLAN.

3. ELECTRICAL CONTRACTOR SHALL PROVIDE

AND INSTALL CABLE TRAY AND ALL CONDUITS

WITH PULL STRINGS AS NOTED.

CABLE TRAY GENERAL NOTES:

4" W x 2" H CABLE TRAY CLEAR ANODIZED

FINISH WITH A WHITE POLYMER LINER SLEEVE

30" WIDE CORNER RADIUS FITTING, 30" WIDE

TEE FITTING AND SPLICE KITS

(2) KEYLESS SPEED LINK STRANDED CABLES

WITH HOOKS AT Y END PER TRAY WITH PURLIN

CLIPS

SPECIFICATIONS:

LIGHT FIXTURE DESCRIPTION

TYPE

DESCRIPTION

WATTS

K

N

SYMB COUNT

14

4

F83

KE3

MANF PART #

J 2

46XSP-3CREE

CREE LED LIGHTING XSP WALL SCONCE,

LED, TYPE III, FULL CUT OFF

30

4' STRIP 30W LED.

MOUNT TOP OF LIGHTS AS INDICATED

ON PLAN. (PENDANT MOUNTING KITS

ORDERED SEPARATELY AS REQUIRED)

3

3

3

EMERGENCY LIGHT (2) HEADS

90 MIN. BATTERY BACK-UP

LED-90-2HLED-WPEXITRONIX

EMERGENCY LIGHT (2) HEADS

90 MIN. BATTERY BACK-UP

VLED-U-WH-EL90-2CLEDEXITRONIX

EMERGENCY LIGHT/EXIT COMBO (2)

HEADS 90 MIN. BATTERY BACK-UP

LED-90-BLANK-2HLEDEXITRONIX

LSG

LSPRO LBAR 48 CW 8030W FR MVOLT

NOTES:

1. ALL POWER POLES ARE TO BE ORDERED BLACK

IN COLOR.

2. ALL POWER POLE WHIPS TO BE 10'-0".

SCALE:

3

E3.1

NTS

FREEZER/COOLER POWER POLE

747DGS019-12'

COOLER POWER POLE

JUNCTION BOXES & PC1D3 &

PC1D4 (TWO CIRCUITS)

INSTALLED BY ELECTRICIAN

(ONE BLACK) 20 AMP

125/250v. NEMA #L-14-20 R

RECEPTACLE

COOLER/FREEZER POWER POLES

Cable kit for 120 volt cooler747DGS019

120 Volt 2 CIR. Power pole

747DGS019-12

125/250 volt Power pole with NEMA

L1420 connection

747DGS030-12

747DGS030

125/250 Cable kit for freezer

Qty. Power Pole DescriptionD&P Part No.

2

2

2

2

SINGLE CHANNEL

FOOT

BRACKET TO MOUNT

TO FLOOR

(2) 1E3-10 EXTENDER CABLE

AND CONNECTOR

SOLD SEPARATELY

(MODEL #747DGS030A)

POLE SECTION VIEW

POWER

CHANNEL

1.625"x2.125"

ID

DATA

CHANNEL

.75"x2.125"

ID

JUNCTION BOXES & PC1D3'S (TWO

CIRCUITS) INSTALLED BY

ELECTRICIAN

SINGLE CHANNEL

FOOT

BRACKET TO MOUNT

TO FLOOR

1E3-10 EXTENDER CABLE

AND CONNECTOR

SOLD SEPARATELY

(MODEL #747DGS019)

20 AMP 120 V.

DUPLEX REC.

POLE SECTION VIEW

POWER

CHANNEL

1.625"x2.125"

ID

DATA

CHANNEL

.75"x2.125"

ID

747DGS030-12'

FREEZER POWER POLE

2 1/4"

2 15/16"

2 1/4"

2 15/16"

747DGS020-12BK

(ONE BLACK) 20 AMP

125/250v. NEMA #L-14-20 R

RECEPTACLE

SINGLE CHANNEL

FOOT

BRACKET TO MOUNT

TO FLOOR

125/250 volt Power pole with NEMA

L1420 connection

747DGS030A 125/250 Cable kit for freezer

Qty. Power Pole DescriptionD&P Part No.

1

1

COOLER/FREEZER POWER POLE

120 Volt 1 CIR. Power pole

1 Cable kit for 120 volt cooler747DGS019A

COOLER/FREEZER POWER POLES

20 AMP 120 V.

DUPLEX REC.

(2) 1E3-10 EXTENDER CABLE

AND CONNECTOR

SOLD SEPARATELY

(MODEL #747DGS030)

(MODEL #747DGS019)

JUNCTION BOXES & PC1FS3 &

PC1FS4 (TWO CIRCUITS)

INSTALLED BY ELECTRICIAN

747DGS020-12BK

1 2 3 4 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RECORD

CONSTRUCTION

BID

520 South Main Street, Suite 2531

Akron, OH 44311

330.572.2100 FAX 330.572.2101

2016408.03

DO

LL

AR

G

EN

ER

AL

N.J. S

TA

TE

R

OU

TE

54 &

R

OU

TE

73

FO

LS

OM

(H

AM

MO

NT

ON

), N

J 08037

11.04.16

03.29.17

-

-

DA

TE

DE

SC

RIP

TIO

N

Dra

win

g N

am

e: O

:\2

01

6\2

01

64

08

\0

3 F

olso

m, N

J\D

wg

\B

ld

g\7

20

_E

3.1

_P

OW

ER

P

OL

E D

ET

AIL

S.D

WG

Ma

rch

2

9, 2

01

7 - a

ko

le

sa

r

E-3.1

PO

WE

R P

OL

E D

ET

AIL

S

MAR WCF

SCALE:

1

E-3.2

NTS

PHONE WIRING FOR REISTER

EXTRA WIRES TO BE WRAPPED AND

TAPED AROUND CABLE

ALL WIRES ARE CAT 5, 4-PAIR

USE SEPARATE RJ-11 JACKS FOR EACH

CONNECTION

RJ-11 JACK

BLUE

BLUE &

WHITE

BLU

E

BLU

E &

W

HIT

E

DMARC

LIN

E #3

LIN

E #2

LIN

E #1

PHONE LINE #1 LABEL AS "PHONE"

RJ-11 JACK: 1 - REGISTER

4

E-3.2

SCALE: NTS

REGISTER POWER POLE

SCALE:

2

E3.2

NTS

REGISTER ELECTRICAL DETAIL

REGISTER ELECTRICAL COMPONENTS

Qty. Power Pole DescriptionD&P Part No. National Account

Provider

B

R

B

R

B

R

1

2

1

2

GREEN/YELLOW=ISOLATED

GROUND

RED=HOT -

CIRCUIT 2

BLACK=HOT

- CIRCUIT 1

WHITE=NEUTRAL

GREEN=SHIELD

GROUND

747DGS023B

GREEN/YELLOW=ISOLATED

GROUND

RED=HOT -

CIRCUIT 2

BLACK=HOT

- CIRCUIT 1

WHITE=NEUTRAL

1D5-IG

GREEN

1D5-IG

GREEN

1D4

BROWN

1D4

BROWN

GREEN=GROUND

WHITE=NEUTRAL

BLACK=HOT -

CIRCUIT 1

RED=HOT -

CIRCUIT 2

747DGS023R

GREEN=GROUND

WHITE=NEUTRAL

BLACK=HOT -

CIRCUIT 1

RED=HOT -

CIRCUIT 2

GREEN=SHIELD

GROUND

12' 2CH Regular Pole W/2-C

& 1-D Connector DRW

#2004-12

Dual circuit power kit with

isolated ground

Dual circuit power kit

10' Cable Kit (Set of 4 whips)

747DGS023R

747DGS023B

1

1

1

1

D & P

D & P

POWER POLE

#747DGS044-126BK

OPEN CEILINGS OR

CEILINGS

HIGHER THAN 10'

WILL REQUIRE

HIGHER POWER

POLES

REG. POWER

(BY ELECTRICIAN)

747DGS032A

FOUR EACH 1E3-10

EXTENDER CABLE

AND CONNECTOR

SOLD SEPARATELY

(MODEL

#747DGS032A)

747DGS044-126BK

NOTES:

1. ALL POWER POLES ARE TO BE ORDERED BLACK

IN COLOR.

2. ALL POWER POLE WHIPS TO BE 10'-0".

*NOTE: BEFORE ORDERING AND INSTALLATION OF

ELECTRICAL COMPONENTS FOR REGISTERS, CONSULT

FINAL FIXTURE PLAN FOR NUMBER AND LOCATION.

MAXIMUM CIRCUITS FOR REGISTERS -

CIRCUITS AT MAIN REGISTER - (9) 110V

CIRCUITS AT ISLAND REGISTER - (3) 110V

BREAKERS FOR SHARED NEUTRAL CIRCUITS SHALL HAVE

HANDLE TIES OR 2-POLE CIRCUIT BREAKER.

1 2 3 4 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RECORD

CONSTRUCTION

BID

520 South Main Street, Suite 2531

Akron, OH 44311

330.572.2100 FAX 330.572.2101

2016408.03

DO

LL

AR

G

EN

ER

AL

N.J. S

TA

TE

R

OU

TE

54 &

R

OU

TE

73

FO

LS

OM

(H

AM

MO

NT

ON

), N

J 08037

11.04.16

03.29.17

-

-

DA

TE

DE

SC

RIP

TIO

N

Dra

win

g N

am

e: O

:\2

01

6\2

01

64

08

\0

3 F

olso

m, N

J\D

wg

\B

ld

g\7

25

_E

3.2

_P

OW

ER

P

OL

E D

ET

AIL

S.D

WG

Ma

rch

2

9, 2

01

7 - a

ko

le

sa

r

E-3.2

PO

WE

R P

OL

E D

ET

AIL

S

MAR WCF

1 2 3 4 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RECORD

CONSTRUCTION

BID

520 South Main Street, Suite 2531

Akron, OH 44311

330.572.2100 FAX 330.572.2101

2016408.03

DO

LL

AR

G

EN

ER

AL

N.J. S

TA

TE

R

OU

TE

54 &

R

OU

TE

73

FO

LS

OM

(H

AM

MO

NT

ON

), N

J 08037

11.04.16

03.29.17

-

-

DA

TE

DE

SC

RIP

TIO

N

Dra

win

g N

am

e: O

:\2

01

6\2

01

64

08

\0

3 F

olso

m, N

J\D

wg

\B

ld

g\7

50

_E

5_

EL

EC

TR

IC

AL

P

AN

EL

C

RIT

ER

IA

.d

wg

---- - a

ko

le

sa

r

E-5

EL

EC

TR

IC

AL

P

AN

EL

CR

IT

ER

IA

MAR WCF

PANEL A NOTES:

1. PANEL A TO BE SERVICE ENTRANCE SERIES RATED WITH AIC RATING OF 65K AIC MAIN AND USING 22K AIC BRANCH

BREAKERS (CONFIRM WITH UTILITY).

2. BREAKERS FOR HVAC UNITS SHALL BE SIZED PER MANUFACTURER REQUIREMENTS.

3. BREAKERS THAT SERVICE HVAC EQUIPMENT AND MOTOR LOADS (COOLERS, FREEZERS, ETC) TO BE HACR.

2

N.T.S.

SERVICE GROUNDING ELECTRODE

SYSTEM WIRING DIAGRAM

7

3

8

5

14

13

12

109

10

11

6

11

18

15

21

4

17

22

11

1

21

20

1

E-5

23

SERVICE GROUNDING DETAIL KEYNOTES:

1. #2/0 AWG GROUNDING ELECTRODE CONDUCTOR CONNECTED TO AN APPROVED

GROUNDING ELECTRODE.

2. NOT USED.

3. SERVICE ENTRANCE CONDUCTORS WITH GROUNDED (NEUTRAL) CONDUCTOR.

4. #2/0 AWG MAIN BONDING JUMPER.

5. UNDERGROUND METAL WATER LINE IN DIRECT CONTACT WITH EARTH FOR AT

LEAST 10'.

6. #6 SOLID COPPER GROUNDING JUMPER TO BE TERMINATED ON TELEPHONE

BACKBOARD.

7. INCOMING SERVICE FROM UTILITY COMPANY TRANSFORMER WITH SECONDARY

GROUNDED PER UTILITY COMPANY REQUIREMENTS.

8. GROUNDING JUMPER AROUND METER AND ANY NONMETALLIC PIPE SECTIONS.

9. UNDERGROUND METAL GAS LINE IN DIRECT CONTACT WITH EARTH FOR AT LEAST

10'. PROVIDE BONDING JUMPER AROUND GAS METER AND ANY NONMETALLIC

PIPE SECTIONS TO BOND METAL PIPING TO GROUNDING SYSTEM PER NEC

250.104(B).

10. CONNECTION SHALL MADE WITHIN 5' OF BUILDING ENTRANCE.

11. CADWELD EXOTHERMIC CONNECTION (TYPICAL).

12. EFFECTIVELY GROUNDED BUILDING STEEL COLUMN.

13. STEEL BASE PLATE.

14. BASE PLATE NUT AND ANCHOR BOLT INTO REINFORCED CONCRETE PIER OR

FOOTING. ANCHOR BOLT BONDED TO CONCRETE REINFORCING.

15. MAIN SERVICE SWITCH OR DISTRIBUTION PANELBOARD.

16. NOT USED.

17. ENCLOSURE GROUND.

18. CONCRETE-ENCASED ELECTRODE (REBAR) AS REQUIRED BY NEC 250.52.

19. BOND CONCRETE-ENCASED ELECTRODE (REBAR) TO BUILDING STEEL WITH #4

AWG PER NEC 250.53.

20. BOND SUPPLEMENTAL ELECTRODE TO THE GROUNDING ELECTRODE SYSTEM

WITH #2/0 AWG PER NEC 250.53.

21. BONDING JUMPER BONDED TO SYSTEM AND TO OTHER POINTS AND EQUIPMENT

AS REQUIRED BY NEC ARTICLE 250.

22. 10' X 3/4" COPPER CLAD GROUND ROD IN EARTH. QUANTITY AS REQUIRED TO

MEET OR EXCEED NEC 250.56 OR AS OTHERWISE STATED ON THE DRAWINGS

AND/OR SPECIFICATIONS WHICHEVER IS MORE RESTRICTIVE.

23. BOND METAL VENEER TO BUILDING STEEL WITH #6 AWG. BOND TO COMPLY WITH

OBC CHAPTER 27, PER SECTION 1405.10.4 OBC.

-

GENERAL PANEL NOTE:

1. ALL BREAKER LABELS TO BE TYPED/PRINTED. NO HAND WRITTEN

LABELS PERMITTED.

19

PROVIDE 3-POLE

BREAKERS AND

HANDLE TIE BOTH

3-POLE BREAKERS

TOGETHER TO

SATISFY NEC 210.7.

NEUTRAL MAY BE

SHARED WITH

3-POLE BREAKER.

PANEL B NOTES:

1. PANEL B SERIES RATED WITH PANEL A.

2. FURNISH & INSTALL 1 AND 2 POLE BREAKERS FOR COOLERS/FREEZERS AS PER FINAL FIXTURE

PLAN. RATING WILL NOT EXCEED 40 AMPS ON DOUBLE POLE BREAKERS. SINGLE POLE CIRCUITS

WILL NOT EXCEED 30 AMPS. VERIFY FINAL REQUIREMENTS PRIOR TO ORDERING BREAKERS AND

WIRE.

3. BREAKERS FOR SHARED NEUTRAL CIRCUIT SHALL HAVE HANDLE TIES OR 2-POLE BREAKER.

ALUMINUM ALTERNATE FOR SERVICE ENTRANCE

CONDUCTORS.

TWO SETS OF 4#300 KCMIL ALUMINUM IN 4" CONDUITS

NOTES:

1. COORDINATE WITH UTILITY COMPANY OR AUTHORITY HAVING JURISDICTION REGARDING SERVICE & METERING. IF AN EXTERIOR DISC.

SWITCH IS REQUIRED BY EITHER THE UTILITY OR AUTHORITY HAVING JURISDICTION, THE EC SHALL FURNISH AND INSTALL PER UTILITY

CO. OR AUTHORITY HAVING JURISDICTION'S REQUIREMENTS.

2. VERIFY BONDING GROUND WIRE REQUIREMENTS WITH LOCAL INSPECTOR PRIOR TO BIDDING.

3. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY AND CALCULATE SHORT CIRCUIT FAULT CURRENT AND ARC FLASH, AND

PROVIDE LABELS ON ELECTRICAL EQUIMENT PER N.E.C. AND LOCAL JURISDICTION.

4. THE SERIES RATED COMBINATION BREAKERS SHALL BE SELECTED BY A PROFESSIONAL ENGINEER BY THE VENDOR, AND A DOCUMENT

STAMPED & SIGNED BY SAME PRESENTED TO BOTH THE OWNER AND GPD GROUP.

(4)#600 KCMIL IN 4" CONDUITS

TRENCHING AND BACKFILL BY E.C.,

COMPLY WITH N.E.C TABLE 300.5.

UTILITY METER BY UTILITY CO.

PROVIDE METER BASE

PER UTILITY COMPANY STANDARDS

PANEL

'A'

400A

MCB

C

±5'-0"

L

SECURE CONDUIT TO

EXTERIOR BUILDING WALL

PANEL

'B'

225A

MLO

4-#4/0 (1)#4 GND., (1)#4 ISO GND.,

IN 2" CONDUIT

PROVIDE SLIP-FITTER IF

REQUIRED BY LOCAL

JURISDICTION.

PAD MOUNTED

TRANSFORMER

INCOMING UTILITY

1

N.T.S.

E-5

ELECTRICAL PANEL SCHEMATIC

E.C. SHALL PROVIDE CT CABINET AND MOUNT ON

EXTERIOR WALL PER UTILITY COMPANY STANDARDS.

COORDINATE LOCATION WITH UTILITY COMPANY.

REFER TO THIS SHEET DETAIL

2/E-5 FOR COMPLETE GROUNDING

SYSTEM AND SIZES

NOTE: PLAN IS DIAGRAMIC ONLY!! HOLD

CONDUIT TIGHT TO EXPOSED MAIN GIRTS

AND RUN AS HIGH AS POSSIBLE ALONG

PERIMETER WALLS TO RECEIVING AREA.

@ 8'-0" A.F.F.

EMERSON PRE-

PROGRAMMED E2 CZ-100

CONTROLLER

"EMS PANEL", MTD. NEXT TO

ELECTRICAL PANELS, AS

CLOSE AS POSSIBLE.

ELECTRICAL PANELS

TS

TS

ST

ST

ST

AT

ST

OT

1

AT

AT

AT

RTU-1

RTU-2

RTU-3

RTU-4

TO RTU-1S

S

TS

1

TO RTU-2

TS

1

TO RTU-3

S

S

1

TO RTU-4

m

m

NOTE:

A. REFER TO SCHEDULE FOR GENERAL CONTRACTOR

RESPONSIBILITIES. E.C. MAY USE CABLE TRAY FOR LOW

VOLTAGE CABLES, SEE 2/E2 FOR CABLE TRAY PLAN.

B. RUN CONDUIT FROM SENSORS TO BOTTOM OF STRUCTURE.

TEMPERATURE SPACE

SENSOR

(809-6590) MTD. @ 8'-0" A.F.F.

SUPPLY TEMP (501-1121)

MTD. IN SUPPLY DUCT

OUTDOOR AIR TEMP

MTD. @ 8'-0" A.F.F.

BELDEN 8761 OR EQUIVALENT

(22AWG, 2C, STRANDED,

SHIELDED)

BELDEN 8761 OR EQUIVALENT

(22AWG, 2C, STRANDED,

SHIELDED)

BELDEN 8761 OR EQUIVALENT

(22AWG, 2C, STRANDED,

SHIELDED)

QTY.

QTY. ONE (1) PER HVAC UNIT.

QTY. ONE (1) PER HVAC UNIT

ZONE.

QTY. ONE (1) PER RECEIVING

ENTRY.

1

EMS

SUPPLIER

GENERAL

CONTRACTOR

EMS

SUPPLIER

GENERAL

CONTRACTOR

EMS

SUPPLIER

HVAC SUB

CONTRACTOR

VERIFY

VERIFY

AHU TERMINAL STRIP

AT

8C T-STAT CABLE QTY. ONE (1) PER HVAC UNIT.VERIFY

EMS

SUPPLIER

GENERAL

CONTRACTOR

RJ-11/RJ-45 DATA JACK,

PHONE COMBO.

24 GA., 4 TWISTED-PAIR,

CATEGORY-FIVE (CAT 5) DATA

CABLE .

QTY. ONE (1) AT OFFICE

COMPUTER CART.

1

GENERAL

CONTRACTOR

GENERAL

CONTRACTOR

DESCRIPTIONSYMBOL CABLE TYPE NOTES

SUPPLIED

BY:

INSTALLED

BY:

OT

ST

TS

S

MOTION SENSOR SWITCH.LEVITON EZ-FIND ODS-10-IDW

QTY. ONE (1) PER MEN'S

RESTROOM.

QTY. ONE (1) PER WOMEN'S

RESTROOM.

4

GENERAL

CONTRACTOR

GENERAL

CONTRACTOR

m

SENSOR PLAN KEYED NOTES

1

2

ALWAYS INSTALL THESE SENSORS AT 8'-0" A.F.F. THE EXACT

MOUNTING LOCATION OF THE HVAC SENSORS "TS" MAY

VARY DEPENDING ON THE STORE LAYOUT & DUCT

CONFIGURATION. REFER TO SITE SPECIFIC MECHANICAL

DRAWINGS FOR HVAC ZONED SENSOR MOUNTING

LOCATIONS. IF SENSORS ARE MOUNTED ON EXTERIOR

WALLS DUE TO DUCT CONFIGURATION, THEY ARE THEN TO

BE INSULATED TO PREVENT AIR INFILTRATION. IF ADDITIONAL

HVAC UNITS ARE USED, ADD ADDITIONAL TEMPERATURE

SENSORS "TS".

PHONE LINE #1 - TWO RJ-11 PORTS. ONE (1) LOCATED IN

OFFICE W/RJ-45 DATA JACK COMBO AND ONE (1) AT

REGISTER. 24 GA. CAT 5, 4-PAIR TWISTED WIRE ONLY. USE

BLUE AND BLUE & WHITE WIRES. HOOK TO LINE #1 TERMINAL

IN RJ-11 JACK EACH PHONE JACK TO HAVE DEDICATED,

SEPARATE HOME RUN TO DMARC. LABEL AS "PHONE" AT THE

DESTINATION AND AT DMARC. PHONE COMPANY PROVIDES

FINAL HOOK UP TO DMARC ONLY.PHONE LINE #2 - RJ-11

PHONE JACK SUPPLIED AND WIRED BY CONTRACTOR.

2

m

m

WOMENS

105

VESTIBULE

107

MENS

104

OFFICE

101

BREAK ROOM

100

HALLWAY

106

SALES AREA

102

RECIEVING AREA

103

1 2 3 4 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RECORD

CONSTRUCTION

BID

520 South Main Street, Suite 2531

Akron, OH 44311

330.572.2100 FAX 330.572.2101

2016408.03

DO

LL

AR

G

EN

ER

AL

N.J. S

TA

TE

R

OU

TE

54 &

R

OU

TE

73

FO

LS

OM

(H

AM

MO

NT

ON

), N

J 08037

11.04.16

03.29.17

-

-

DA

TE

DE

SC

RIP

TIO

N

Dra

win

g N

am

e: O

:\2

01

6\2

01

64

08

\0

3 F

olso

m, N

J\D

wg

\B

ld

g\7

60

_ E

MS

1-S

EN

SO

R L

OC

.d

wg

Ma

rch

2

9, 2

01

7 - a

ko

le

sa

r

EMS-1

SE

NS

OR

L

OC

AT

IO

N P

LA

N

MAR WCF

1/8" = 1'-0"

EMS-1

1 SENSOR LOCATION PLAN

ON

278 6 45 3 1

ON

278 6 45 3 1

ON

278 6 45 3 1

ON

278 6 45 3 1

ON

HVAC1 24Vac

HVAC1 Supply Fan

HVAC1 Heat1

HVAC1 Heat2

HVAC1 Cool1

HVAC1 Cool2

HVAC2 24Vac

HVAC2 Supply Fan

HVAC2 Heat1

HVAC2 Heat2

HVAC2 Cool1

HVAC2 Cool2

HVAC3 24Vac

HVAC3 Supply Fan

HVAC3 Heat1

HVAC3 Heat2

HVAC3 Cool1

HVAC3 Cool2

HVAC4 24Vac

HVAC4 Supply Fan

HVAC4 Heat1

HVAC4 Heat2

HVAC4 Cool1

HVAC4 Cool2

HVAC5 24Vac

HVAC5 Supply Fan

HVAC5 Heat1

HVAC5 Heat2

HVAC5 Cool1

HVAC5 Cool2

HVAC6 24Vac

HVAC6 Supply Fan

HVAC6 Heat1

HVAC6 Heat2

HVAC6 Cool1

HVAC6 Cool2

50VA

Dusk To Dawn

Outside Perimeter

Sign Lights

Lights

Lights

Receiving

& Night lights

70% Lights

30% Lights

70% Lights

C1

C2

C7

C8

C3

C4

C5

C6

Outside Perimeter

Lights

COM 485 OUT

JP

2

JP

3

JP

4

S2 FAILSAFE

AC

1

0V

AC

2

POWER

RS485

+0

V-

(24VAC)

J10(HHT)

CP

C P

AR

T#

23

7-3

00

6 V

ER

. 1

.0

0

S1 NETWORK

Rx

Tx

Status

General

OUT1 OUT7OUT4OUT3OUT2 OUT5 OUT6 OUT8

2 7 864 5312 7 864 531

ON

BOARD NO.:

ON

Normal Test

24vAC

120vAC

10VA

24VCT 24V

C

120

208240

80VA

PANEL/CIRCUIT

PANEL/CIRCUIT

DOOR SW FRONT

DOOR SW EM./EXIT

DOOR SW RECEIVING

AC#1 SPACE TEMP

AC#1 SUPPLY TEMP

HVAC Control Wires To Utilize

Standard 8 Conductor, 18 Ga.,

Color Coated. See Photo This

Sheet.

AC#2 SPACE TEMP

AC#2 SUPPLY TEMP

AC#3 SPACE TEMP

AC#3 SUPPLY TEMP

SPARE

OUTSIDE

TEMPERATURE

MOTION SENSOR

RECEIVING

AC#4 SPACE TEMP

AC#4 SUPPLY TEMP

AC#5 SPACE TEMP

AC#5 SUPPLY TEMP

COOLER TEMP.

AC#6 SPACE TEMP

AC#6 SUPPLY TEMP

COOLER TEMP.

FREEZER TEMP.

FREEZER TEMP.

FREEZER TEMP.

Se

nso

r

24

Va

c

Mo

tio

n

Se

nso

r

24

Va

c

Mo

tio

n

COPPER

CONDUCTORS ONLY

2 AMP, 250 VOLT

FAST BLOW BUSS

GMA-2A OR

EQUIVALENT

INPUT POWER: 24VAC, 15VA,

50/60 Hz CLASS 2 POWER

ONLY. OUTPUTS, EACH:

240VAC,1.2A MAX.

S2 FAILSAFE ON(UP) For N.C.

Outputs OFF(DOWN) For N.O. Outputs

ICE CREAM

FREEZER TEMP

DAIRY COOLER

TEMP

LUNCH MEAT

COOLER TEMP

MOTION SENSOR FRONT

(WIRE PER MFG. INSTRUCTIONS)

MU

LT

IF

LE

X 1616L

CP

C P

AR

T#810-3072

FO

R IN

PU

TS

1-8

FO

R IN

PU

TS

9-16

FO

R 16A

I B

OA

RD

FO

R 8R

O (2 U

sed)

S3-N

ET

WO

RK

AD

DR

ES

S, B

AU

D

S4-N

ET

WO

RK

AD

DR

ES

S, B

AU

D

S1-S

EN

SO

R T

YP

E

SE

LE

CT

S

2-S

EN

SO

R

TY

PE

S

ELE

CT

SENSOR

CONNECTIONS

16AI 1

8RO

1,2

237-3068 Ver.

1.00 1616

LAO/LDO

278 6 45 3 1

ON

278 6 45 3 1

ON

278 6 45 3 1

ON

278 6 45 3 1

ON

MU

LT

IF

LE

X 1616L

CP

C P

AR

T#810-3072

FO

R IN

PU

TS

1-8

FO

R IN

PU

TS

9-16

FO

R 16A

I B

OA

RD

FO

R 8R

O (2 U

sed)

S3-N

ET

WO

RK

AD

DR

ES

S, B

AU

D

S4-N

ET

WO

RK

AD

DR

ES

S, B

AU

D

S1-S

EN

SO

R T

YP

E

SE

LE

CT

S

2-S

EN

SO

R

TY

PE

S

ELE

CT

237-3068 Ver.

1.00 1616

LAO/LDO

B/13

B/15

B/5

B/7

B/9

B/11

B/27

B/29

B/23

B/25

B/1

B/3

EMS GENERAL NOTES

1. EMS SUPPLIER NOTE: CUSTOMIZED DOLLAR GENERAL

EMS PANEL REQUIRES STORE #, CITY, STATE, ZIP CODE

& QTY. OF HVAC UNITS OF THE INSTALL SITE WHEN

ORDERING. EMS SYSTEMS INSTALLATION GUIDE WITH

PHOTOS IS AVAILABLE ON NATIONAL ACCOUNT WEBSITE.

ALL QUESTIONS PERTAINING TO THE EMS PANEL,

SYSTEM INSTALLATION & SETUP SHOULD BE DIRECTED

TO EMERSON'S DOLLAR GENERAL SUPPORT TEAM AT

770-425-2724.

2. ALL SIGN & LIGHTING CIRCUITS MUST BE FED THROUGH

THE DESIGNATED CONTACTORS AS NOTED ON THIS

PAGE.

3. ALL LOW VOLTAGE HVAC & DOOR SENSORS MUST BE

CONNECTED TO THE PROPER TERMINAL. 24 GA.

SHIELDED (SHIELD MUST BE GROUNDED) CABLE, BELDEN

#8641, 2 CONDUCTOR WIRE OR IT'S EQUIVALENT IS

REQUIRED.

4. COOLER & FREEZER HOME RUNS WILL BE TERMINATED

AT ALL POINTS BY DOLLAR GENERAL REFRIGERATION

DEPARTMENT.

TESTING NOTES

TESTING OF HVAC UNITS THRU EMS PANEL IS

ACCOMPLISHED BY SIMPLY WARMING UP OR

COOLING DOWN A SPACE TEMPERATURE SENSOR

(USING A BLOW DRYER OR ELECTRONIC EQUIPMENT

DUSTER AEROSOL) AND WATCH THE FAN, HEAT AND

COOL STAGES CYCLE ON AND OFF. THIS REQUIRES

TWO PEOPLE AT ALL TIMES....ONE TO WATCH THE

SCREEN AND THE OTHER TO WATCH OPERATION OF

THE AHU. WHEN COMPLETE, PRESS THE HOME

BUTTON TO RETURN TO THE MAIN SCREEN.

NOTE:

EMS SYSTEM SHOULD BE TESTED FOR HVAC

OPERATION, INTERIOR LIGHTING, EXTERIOR LIGHTING

AND SIGN LIGHTING PRIOR TO CONTRACTOR'S

ELECTRICAL POSSESSION DATE. USE OUTSIDE LIGHT

AND SIGN LIGHT OVERRIDE FOR EXTERIOR TESTING.

GENERAL CONTRACTOR TO

ENSURE THAT THE BATTERY

ENABLE IS SWITCHED TO THE

"ON" POSITION

!

Inside lights override Sign light override

CAUTION!

Outside light override

Pre-Programmed e2 cx-100 Controller

!

Escalation Contact List

If you need HVAC Maintenance,

call 866-300-0004, option 1.

If you have Temperature Set Point

concerns, contact your District

Manager.

If you are having problems with

your Lights, call 866-300-0004,

option 6.

If you are having problems with

your Coolers, call 866-300-0004,

option 2.

If you are having problems with

your Sign, call 866-300-0004,

option 1.

If your store hours change, call

866-300-0004, option 6.

Verifying the Time and Date

From the Home screen.

1. The Date is in the upper left corner of the Home screen.

2. The Time is in the upper right corner of the Home screen.

HVAC Control Status

* Press the Home screen button.

* Select F1 AHU.

* Using the arrow keys, highlight the appropriated HVAC Unit, select enter.

* From the screen you can view:

i. Ctzl Temp (Control Temp - The sales floor temp).

ii. Values in [ ] represent the set point we are trying to maintain.

iii. Space Temp (Temperature at problem on Sales Floor).

iv. Supply Temp (Air Temp leaving AHU).

v. Status of Fan/Heat/Cools

* When complete, select the Home button.

Lighting Status

* The status of Store Lights can be viewed in the bottom left corner of the Home page, or by the following:

* Press the Home screen button.

* Select F2 Lighting.

* Highlight the appropriate Lighting Control, then select enter.

* When complete, select the Home button.

Refrigerated Case Status

* Case Temperature can be viewed from the Home screen.

To view a graph of the case temperature:

i. Highlight the Temp value and select enter.

ii. Select 1 for graph.

To zoom select F5 Zoom-In.

(Press F5 Zoom-In as many times as necessary, get to the desired scale/range).

(Use the left and right arrow keys to move to the time/date range desired).

* When complete, select the Home button.

Alarm Status

From the Home screen, select Alarm button.

1. Date: The date the alarm occured.

2. Time: The time the alarm occured.

3. State: Notice, Alarm or Fail.

* Notices are general warnings that notify a user of minor errors.

* Alarms are warnings about important system conditions that need immediate attention.

* Fails are high priority conditions, warning the user of a controller or device failure.

4. Property on Board and Point: The item that has generated the alarm.

5. Message: The description of the notice, alarm or fail.

a. Using the up or down arrow keys, highlight the appropriate alarm and select F4 Expd. Info.

i. Expd. Info: Expanded Information will give the unit & detailed status on the alarm.

ii. When finished viewing detailed status, select enter.

* When complete, select the Home button.

Load licenses if

applicable

528-5134

528-5096

Load E2 Setpoints

file Load IP address

information

All power must be shut

off prior to wiring,

installation, or service.

More than one

disconnect may be

required to de-energize

this panel.

B/33

B/35

1

N.T.S.

CPU TERMINAL DIAGRAM

EMS-2

2

N.T.S.

PROGRAMMER CONTROLLER

EMS-2

3

N.T.S.

CONTROLLER WIRING DIAGRAM

EMS-2

1 2 3 4 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RECORD

CONSTRUCTION

BID

520 South Main Street, Suite 2531

Akron, OH 44311

330.572.2100 FAX 330.572.2101

2016408.03

DO

LL

AR

G

EN

ER

AL

N.J. S

TA

TE

R

OU

TE

54 &

R

OU

TE

73

FO

LS

OM

(H

AM

MO

NT

ON

), N

J 08037

11.04.16

03.29.17

-

-

DA

TE

DE

SC

RIP

TIO

N

Dra

win

g N

am

e: O

:\2

01

6\2

01

64

08

\0

3 F

olso

m, N

J\D

wg

\B

ld

g\7

70

_ E

MS

2-P

NL

C

NT

LS

.d

wg

Ma

rch

2

9, 2

01

7 - a

ko

le

sa

r

EMS-2

CP

U T

ER

MIN

AL

D

IA

GR

AM

,

EM

S P

AN

EL

&

C

ON

TR

OL

S

MAR WCF

FOR

REFERENCE

ONLY

(1) CIRCUIT FOR SITE LIGHTING

FIXTURES IN (1) 1" PVC SCH. 40

UNDERGROUND CONDUIT. CIRCUIT

SHALL BE (2)#8, (1)#8 GND. (CKT. B/27)

SCALE: 1/16" = 1'0"

UNDERGROUND

ELECTRIC AND

TELEPHONE

SERVICES,

COORDINATE

WITH UTILITY

COMPANIES.

PROPOSED

DOLLAR GENERAL

BUILDING

REFER TO SHEET E-5 FOR

ELECTRICAL SERVICE

INFORMATION.

(1) CIRCUIT FOR SITE

LIGHTING FIXTURES.

CIRCUIT SHALL BE

(2)#6, (1)#6 GND.

(CKT. B/29)

AND

(1) CIRCUIT FOR

PYLON SIGN.

CIRCUIT SHALL BE

(2)#8, (1)#8 GND.

(CKT. B/25)

IN (1) 1 1/2" PVC SCH.

40 UNDERGROUND

CONDUIT, SCH. 80

UNDER DRIVE AND

PARKING.

PROPOSED PAD MOUNTED TRANSFORMER.

COORDINATE FINAL LOCATION WITH UTILITY

COMPANY.

LUMINAIRE SCHEDULE

SYMBOL QTY LABEL DESCRIPTION ARRANGEMENT LUMENS LLF

2 XSP-3 SINGLE 4187CREE LED LIGHTING XSP WALL SCONCE, LED, TYPE 3.90

3

1

2

CREE LED LIGHTING OSQ SERIES, LED, TYPE 4OSQ-4-DBL

BACK-BACK

10895

.90

.90

.90

9124

9235

OSQ-4-HS

CREE LIGHTING OSQ SERIES, LED, TYPE 4

SINGLE

SINGLECREE LIGHTING OSQ SERIES, LED, TYPE 3OSQ-3-HS

1 2 3 4 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RECORD

CONSTRUCTION

BID

520 South Main Street, Suite 2531

Akron, OH 44311

330.572.2100 FAX 330.572.2101

2016408.03

DO

LL

AR

G

EN

ER

AL

N.J. S

TA

TE

R

OU

TE

54 &

R

OU

TE

73

FO

LS

OM

(H

AM

MO

NT

ON

), N

J 08037

11.04.16

03.29.17

-

-

DA

TE

DE

SC

RIP

TIO

N

Dra

win

g N

am

e: O

:\2

01

6\2

01

64

08

\0

3 F

olso

m, N

J\D

wg

\B

ld

g\8

10

_E

S1

_E

LE

CT

RIC

AL

S

IT

E L

IG

HT

IN

G P

LA

N.D

WG

Ma

rch

2

9, 2

01

7 - a

ko

le

sa

r

ES-1

EL

EC

TR

IC

AL

S

IT

E

PL

AN

MAR WCF

1/16" = 1'-0"

ES-1

1 ELECTRICAL SITE PLAN

SITE LIGHTING NOTES

1. FINAL SIGN CONNECTION AND UNDERGROUND CONDUIT IS LANDLORD

RESPONSIBILITY. PROVIDE CONDUIT FROM THE ELECTRICAL PANEL TO

LOCATION OF THE PYLON SIGN BASE. BURY CONDUIT UNDER PARKING AREA.

THE CONDUIT IS TO BE 1 1/2" AND HAVE ONE SET TO 8/2 WIRE WITH GROUND

AND A 20-AMP TWO POLE BREAKER AT THE PANEL. A TEMPORARY 3' TALL

STAKE SHALL BE PROVIDED TO DESIGNATE THE PYLON SIGN LOCATION UNTIL

THE SIGN IS PERMANENTLY INSTALLED. REMOVE POST AFTER SIGN IS

INSTALLED.

2. SITE / PARKING LOT LIGHTING: PROVIDE ADEQUATE POLE AND/OR WALL

LIGHTING FOR NIGHT VISION AROUND ENTRY, PARKING AND DUMPSTER PAD

AREAS.

3. MINIMUM OF TWO FOOT-CANDLES REQUIRED FOR ALL PAVED AREAS

EXCLUDING 15' PERIMETER FROM EDGE OF PAVEMENT.

4. REQUIRED LIGHTING: A COMBINATION OF POLE LIGHTS, BI-DIRECTIONAL

SECURITY LIGHTS AND WALL PACKS WILL BE USED. REFER TO ELECTRICAL

SITE PLAN AND SHEET E2 FOR ADDITIONAL INFORMATION.

5. PLEASE NOTE THAT LIGHTING DESIGN AND LAYOUT SHOULD BE SITE SPECIFIC

& MAY REQUIRE ADDITIONAL LIGHTING TO COMPLY WITH SITE DESIGN

CONDITIONS. THEREFORE, MAKE PROVISIONS FOR MORE POLE LIGHTING

WHEN A SPECIFIC SITE REQUIRES IT.

6. UNDERGROUND ELECTRICAL SHALL BE PROVIDED TO THE SITE LIGHT POLES.

7. WHERE LOCAL JURISDICTIONS DO NOT ALLOW DOLLAR GENERAL'S REQUIRED

LIGHTING PLAN, AN ALTERNATE SITE LIGHTING PLAN & PHOTOMETRIC PLAN

MUST BE SUBMITTED FOR APPROVAL TO THE DOLLAR GENERAL

AUTOCAD-STORE PLAN DEPARTMENT.

8. PHOTO METRIC SITE ANALYSIS AVAILABLE THROUGH DOLLAR GENERAL

VENDORS: ORION ENERGY SYSTEMS - BRENDAN HARTT 1-904-380-5033

[email protected].

9. DOLLAR GENERAL VENDOR PRICING FOR WALL PACKS OR POLE LIGHTING

AVAILABLE FROM: ORION ENERGY SYSTEMS - BRENDAN HARTT

1-904-380-5033 [email protected].

10. SEE SHEET E2 FOR MORE INFORMATION.

11. VERIFY LOCAL DARK SKY REQUIREMENTS AND CONTACT ORION ENERGY

SYSTEMS FOR APPROVED ALTERNATES IF REQUIRED.

12. CONTRACTOR SHALL COORDINATE WITH LOCAL JURISDICTION ON THE USE OF

LIGHT POLE HANDHOLES FOR J-BOXES. PROVIDE WP J-BOX IF REQUIRED AT

BOTH SIGN AND POLES.