E-1 - Clarke Contracting, LLCclarkecontracting.biz/Projects/Dollar General/Plans/Dollar...
Transcript of E-1 - Clarke Contracting, LLCclarkecontracting.biz/Projects/Dollar General/Plans/Dollar...
SO
DA
CO
OL
ER
SODA
COOLER
IC
E C
RE
AM
FR
EE
ZE
R
GATOR
ADE
A/4
A/8
BUZZER
A/4
BUZZER
PUSH BUTTON
BRING RIGID PIPE
SLEEVE THROUGH
BUILDING TO
ALLOW PHONE
LINE
PENETRATION.
SEAL ALL
PENETRATIONS.
POWER FOR
IRRIGATION
CONTROL BOX.
COORDINATE EXACT
POWER
REQUIREMENTS
PRIOR TO ROUGH-IN.
ELECTRIC METER
BY UTILITY CO.
REFER TO 1/E-5
FOR SERVICE
DETAILS
A/33
1
B/8
B/8
B/8
AUTOMATIC DOOR A/2
A/26
PROVIDE 240V/1Ø, 30A NON
FUSED DISC. AT RESTROOM
WATER HEATER CKT. A/29,31
2#10, 1#10G, 3/4"C
GFCI
PROVIDE 1 POLE TOGGLE
SWITCH AT EXHAUST FAN
CEILING MOUNTED
EXHAUST FAN EF-2.
MOTION SENSOR
CONTROLLED.
CKT. A/16
CEILING MOUNTED EXHAUST
FAN EF-1. MOTION SENSOR
CONTROLLED. CKT. A/14
PROVIDE 1 POLE TOGGLE
SWITCH AT EXHAUST FAN
COORDINATE THE FINAL LOCATION
AND AMOUNT OF REGISTERS WITH
THE APPROVED FIXTURE PLAN.
EF-1
EF-2
MOUNT RECEPTACLE WITHIN
18" OF TOP OF WINDOW
A/30
DEDICATED, WP, GFCI
RECESSED @ 4' A.F.F.
4'-0
"
DEDICATED, WP, GFCI, 20 AMP
OUTLET RECESSED @ 4' A.F.F.
FOR ICE MERCHANDISER
4'-0
"
A/10
A/12
PROVIDE 240V/1Ø, 30A NON
FUSED DISC. AT RECEIVING
AREA WATER HEATER EWH-1
CKT. A/25,27
2#10, 1#10G, 3/4"C
AUTOMATIC DOOR A/28
A/34,36
2#10, 1#10GND. IN 3/4" CONDUIT
FOR CEILING MOUNTED
VESTIBULE CABINET UNIT HEATER.
PROVIDE 30A NON-FUSED
DISCONNECT SWITCH.
REFER TO SHEETS E3.2 FOR
WIRING INFORMATION.
(B/30,32,34,36,38,40)
4
E1
NOTE:
CONFIRM LOCATION OF ALL POWER
POLES WITH FIXTURE PLAN.
SEE SHEET E-3.1 FOR
ADDITIONAL INFORMATION.
2
E1
3
E1
GATORADE COOLER
@4'-0" A.F.F.CKT
B/28
RIGID CONDUIT ANCHOR
TO PURLINS ABOVE.
(TYP OF 4)
ICE CREAM FREEZER
CKT. B/26
TERMINATE @ 78"AFF
SODA COOLER
CKT. B/24
TERMINATE @ 78"AFF
SODA COOLER
CKT. B/22
TERMINATE @ 78"AFF
DRINK COOLER CKT. B/20
TERMINATE @ 48"AFF
RTU-1
RTU-2
RTU-3
RTU-4
2
TYP
A/24
GFCI WP
CKT.
A/7,9,11 4
TYP
6
TYP
A/24
GFCI WP
CKT.
A/1,3,5
RTU-4
CKT.
A/19,21,23 A/24
GFCI WP
A/24 GFCI WP
WOMENS
105
VESTIBULE
107
MENS
104
OFFICE
101
BREAK ROOM
100
HALLWAY
106
SALES AREA
102
RECIEVING AREA
103
PROVIDE 240V, 30A FUSED H.D. DISC. SWITCH IN NEMA 3R
ENCLOSURE FOR WELL PUMP.
1" PVC SCH. 40 UNDERGROUND CONDUIT. CIRCUIT SHALL BE
(2)#12, (1)#12 GND. (CKT. B/55,57)
PUMP, 1HP, 240V, 1Ø.
B/59
B/59
WATER WELL
EQUIPMENT.
SEE NOTE 19.
SEE
SPECIFICATION
#18.
LOCATED ALL CONDUIT TO
OFFICE IN THIS WALL.
B/6
A/20
B/4
B/6
A/18
A/22
B/6
DEDICATED QUAD
RECEPT. @6'-0" FOR
VSAT, D-LINK EQUIP ON
PLYWOOD BACKBOARD.
DED. DUPLEX RECEPT
@48" FOR INTERFACE ON
PLYWOOD BACKBOARD.
SECURITY OUTLET
AT 7'-0" AFF
DEDICATED
QUAD
RECEPT
@3'-0" FOR
CCTV EQUIP.
DEDICATED
QUAD
RECEPT
@3'-0" .
1/A-4
BEFORE ORDERING AND INSTALLATION OF ELECTRICAL COMPONENTS FOR
FREEZERS AND COOLERS, CONSULT FINAL FIXTURE PLAN FOR NUMBER AND LOCATION.
MAXIMUM CIRCUITS FOR COOLERS/FREEZERS - (5) 120V AND (3) 208V.
S030 - FREEZER
POWER POLE.
REFER TO
SHEET E3.1.
S020 - FREEZER/ COOLER
POWER POLE.
REFER TO SHEET E3.1.
S019 - COOLER
POWER POLE.
REFER TO SHEET E3.1.
NOTE:
1. MINIMUM WIRE SIZE TO BE #8 FOR ALL COOLERS & FREEZERS.
2. REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS.
B/37,39
B/41,43
B/45,47
B/46
B/48
B/50
B/52
B/54
1 2 3 4 5
B
A
JOB NO.
D
C
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 FAX 330.572.2101
2016408.03
DO
LL
AR
G
EN
ER
AL
N.J. S
TA
TE
R
OU
TE
54 &
R
OU
TE
73
FO
LS
OM
(H
AM
MO
NT
ON
), N
J 08037
11.04.16
03.29.17
-
-
DA
TE
DE
SC
RIP
TIO
N
Dra
win
g N
am
e: O
:\2
01
6\2
01
64
08
\0
3 F
olso
m, N
J\D
wg
\B
ld
g\7
00
_E
1_
PO
WE
R P
LA
N.D
WG
Ma
rch
2
9, 2
01
7 - a
ko
le
sa
r
E-1
PO
WE
R P
LA
N
MAR WCF
1/8" = 1'-0"
E-1
1 POWER PLAN
2 ELECTRICAL PANEL ELEVATION
3/4" = 1'-0"
E-1
125V NEMA 5-20R QUAD.
A/23
PANEL/CIRCUIT IN PANEL
S
20 AMP TOGGLE SWITCH
NIGHT LIGHT CIRCUITNL
S
m
PROVIDE OCCUPANCY LIGHT
SENSOR- LEVITON ODS10-IDW
LEGEND
BLACK MAGIC POWER POLE
125V NEMA 5-20R DUPLEX.
PANEL/CIRCUIT IN PANEL
PHONE JACK @ REGISTER
125/250V NEMA L14-20-R
4 PRONG TWIST LOCK
BUZZER - TORK MDL #TA725 W/
TRANSFORMER MDL#TA592
DISCONNECT
A/23
VOICE/DATA PORT = RJ-11,
RJ-45 DATA JACK, PHONE
COMBO @ OFFICE
PUSH BUTTON
1. ALL EXPOSED WIRING SHALL BE CONTAINED IN CONDUIT SIZED PER THE N.E.C.
2. BELOW GRADE AND IN SLAB: PVC SCHEDULE 40.
3. ABOVE GRADE OUTDOORS: PVC SCHEDULE 80.
4. ABOVE GRADE INDOORS: EMT, RGS IF EMT CAN BE DAMAGED. MC CABLE WITH CU
GREEN CODE SIZE GROUND INSIDE WALLS AND ABOVE CEILINGS ONLY, IF APPROVED
BY BOTH THE OWNER AND LOCAL JURISDICTION. ALL BOXES AND DEVICES SHALL BE
BONDED TO THE GROUND CONDUCTOR.
5. ALL WIRING SHALL CONFORM TO LOCAL, STATE, AND FEDERAL CODES.
6. SERVICE SHALL BE MINIMUM 400 AMP, 208V-3 PHASE, 600 AMP, 240V-1 PHASE, OR
LARGER IF REQUIRED BY CODE OR ELECTRICAL LOAD. SEE ONE-LINE.
7. REQUIRED CUSTOM BUILT POWER POLE ASSEMBLIES AVAILABLE FROM D&P CUSTOM
LIGHTS & PRODUCTS INC., PHONE: (800) 251-2200 OR (615) 350-7800, 7111 COCKRILL BEND
INDUSTRIAL ROAD, NASHVILLE, TN 37209. SEE E3.1.
8. EXTERIOR EXPOSED PHONE LINES SHALL BE INSTALLED IN RIDGED CONDUIT. PROVIDE
EMERSON 3/4" X 5-FT. METALLIC CABLE U-GUARD #755, OR EQUAL.
9. ELECTRICAL PANEL SHALL BE LABELED CORRECTLY AND WITH LEGIBLE PRINT.
10.PROVIDE SHORT CIRCUIT CALC. & LABELS. PROVIDE ARC FLASH STUDY & LABELS.
11.PROVIDE 4" EMT CONDUIT WITH PULL STRING TO ACT AS ACCESS SLEEVE TO ALLOW
PHONE COMPANY TO TERMINATE AT DMARC. CONTRACTOR TO PROVIDE & INSTALL
PHONE WIRING & RJ-11 PHONE JACK FOR A COMPLETED WORKING SYSTEM PRIOR TO
PHONE COMPANY FINAL HOOK-UP.
12. ALL 120 VOLT OUTDOOR RECEPTACLES SHALL HAVE "WET LOCATION - IN USE"
WEATHERPROOF COVERS.
13. ALL CONDUCTORS TO BE COPPER, #12 AWG MINIMUM SIZE, OR SIZE AS REQUIRED BY
LOAD AND OVER CURRENT PROTECTION.
14.SEE EMS SHEETS EMS-1 & EMS-2 FOR ENERGY MANAGEMENT SYMBOLS AND
INFORMATION.
15.ELECTRICIAN SHALL PROVIDE 1
1
2
" CONDUIT WITH PULL STRING FOR SATELLITE LINE.
REFER TO 4/A-3 FOR LOCATION.
16.G.C. SHALL INSTALL A KNOX BOX IN LOCATION SELECTED BY LOCAL FIRE CODE
AUTHORITY PER LOCAL JURISDICTION REQUIREMENTS. KNOX BOX SHALL BE FLUSH OR
SURFACE MOUNTED.
17. ALL POWER AND DATA TO BE ROUTED OVERHEAD. UNDER SLAB NOT ALLOWED.
18.LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL ONE (1) 24 GA., 4 TWISTED-PAIR,
CATEGORY-FIVE (CAT5) DATA CABLE WITH MODULAR COMBO RJ-11/RJ-45 JACK AT
MANAGER'S OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB LOCATION WITH 6'-0"
LEFT COILED FOR INSTALLATION TO DATA HUB. A RJ-45 MALE FITTING SHOULD BE
CRIMPED ON THIS END. DOLLAR GENERAL STORE OPENING TEAM WILL MAKE FINAL
CONNECTION INTO THE DATA HUB.
19.E.C. SHALL PROVIDE RECEPTACLES WIRED TO CIRCUIT B-59 (20/1) FOR WATER WELL
EQUIPMENT (FILTER AND SOFTENER). COORDINATE EXACT POWER REQUIREMENTS AND
LOCATION WITH MANUFACTURER/INSTALLER PRIOR TO ROUGH-IN .
1. TEST/RESET STATION FOR STAND ALONE DUCT
DETECTOR. ONE FOR EACH DEVICE, SEE KEY NOTE
3 ON THIS SHEET. SYSTEM SENSOR IS SPECIFIED
WITH REMOTE TEST STATION MODEL RTS2.
2. MECHANICAL THERMOSTAT AT 8'-0" A.F.F.
3. LOCATIONS SHOWN FOR MECHANICAL UNITS ARE
ONLY APPROXIMATE, CONTRACTOR MUST
CONSULT MECHANICAL OR STRUCTURAL
DRAWINGS TO DETERMINE ACTUAL UNIT
LOCATIONS. PROVIDE 1/2"C. PENETRATION THRU
ROOF WITHIN FOOTPRINT OF UNIT FOR USE WITH
CONTROL WIRING TO UNIT BY OTHERS. PROVIDE
PROPER WATERSEAL. (TYPICAL)
4. FACTORY MOUNTED NON-POWERED CONVENIENCE
OUTLET PROVIDED WITH UNIT. WIRE TO CIRCUIT
INDICATED.
5. PHOTOELECTRIC DUCT DETECTOR WITH HOUSING.
TIE TO LED READOUT RECESSED IN CEILING.
STAND ALONE DEVICE, 120V. SYSTEM SENSOR
#D4120 IS SPECIFIED WITH #RTS2 CONTROL
STATION. PROVIDE ONE DEVICE PER UNIT. MOUNT
DEVICE IN SUPPLY AIR DUCTWORK. DEVICE SHALL
BE PROVIDED AND WIRED TO THE CONTROL
STATION BY THE ELECTRICAL CONTRACTOR. HIRE
THE MECHANICAL CONTRACTOR FOR
INSTALLATION IN DUCTWORK & CONNECTION TO
SHUTDOWN CONTROLS. ELECTRICAL
CONTRACTOR SHALL PROVIDE ALL REQUIRED
RELAYS AND 120V POWER, DO NOT POWER DUCT
DETECTORS FROM HVAC UNIT LOW VOLTAGE .
SUBMIT SHOP DRAWINGS FOR APPROVAL. PLACE
ANY REQUIRED LABELING ON CEILING TILE
DIRECTLY BELOW UNIT. RUN CONDUIT & WIRE
UNDERGROUND FROM UNIT TO INSIDE OF SPACE.
6. MOUNT DISCONNECT SWITCH AT UNIT. ALL
DISCONNECTS TO BE HEAVY DUTY. FUSES TO BE
RK-5 TYPE, BUSSMANN FRN-R-(AMP) IS SPECIFIED.
ALL WIRING SHALL BE CONTAINED IN CONDUIT OF
PROPER SIZE PER N.E.C.
ELECTRICAL
KEYED NOTES
#
4 COOLER/FREEZER RECEPTACLE LAYOUT
N.T.S
E-1
6'-4"
DMARC
PANEL
A
PANEL
B
3/4" PLYWOOD 8' WIDE X 5'-5" HIGH, FIRE
RATED, NO VOIDS, PAINTED WHITE
UNLESS CODE DICTATES OTHERWISE.
FLOOR LINE
DUPLEX RECEPTACLE
DEDICATE CIRCUIT
TELEPHONE CONDUIT STUB
THROUGH WALL. SEE ELECTRICAL
SPECIFICATION NOTE #8 AND #11.
EMS
A/6
1'-1" 5" 5"1'-8" 1'-8"
1'-8"1'-1"
8'-0"
3 LARGE SCALE OFFICE PLAN
N.T.S
E-1
ELECTRICAL SPECIFICATIONS:
B/16
B/5
B/17
F F F F F F F F
F
F
F
F
F
F
F
F
F
F
F
F
F F
F
F F
F
F F
F
F
F
F
F
FF
F
F
F
FF
FF
F
FF
F
F
F
FF
F
F
F
F
F
F
F
F
F F
F
F
F
B/13 B/15 B/11
B/9
B/7
F
NIGHT LIGHT CIRCUIT
LEGEND
EMERGENCY LIGHT
WALL PACK
PANEL/CIRCUIT NO.
A/12
NL
K
EMERGENCY LIGHT
AND EXIT COMBO
K.1
F
J.1
OCCUPANCY LIGHT
SENSOR -LEVITON -
ODS10-IDW
LIGHT FIXTURE TYPE
B
N.1
LIGHT FIXTURE TYPE
F
1 2 3 4 5
B
A
JOB NO.
D
C
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 FAX 330.572.2101
2016408.03
DO
LL
AR
G
EN
ER
AL
N.J. S
TA
TE
R
OU
TE
54 &
R
OU
TE
73
FO
LS
OM
(H
AM
MO
NT
ON
), N
J 08037
11.04.16
03.29.17
-
-
DA
TE
DE
SC
RIP
TIO
N
Dra
win
g N
am
e: O
:\2
01
6\2
01
64
08
\0
3 F
olso
m, N
J\D
wg
\B
ld
g\7
10
_E
2_
LIG
HT
IN
G P
LA
N.d
wg
---- - a
ko
le
sa
r
E-2
LIG
HT
IN
G P
LA
N
MAR WCF
1/8" = 1'-0"
E-2
1 LIGHTING PLAN
NOTE: ALL NIGHT LIGHTS, EMERGENCY
LIGHTS, AND EXIT SIGNS SHALL BE
WIRED AHEAD OF ALL LOCAL SWITCHING
TO LIGHTING CIRCUIT INDICATED.
EMERGENCY/EXIT SIGNS AND LIGHTS: INSTALL
EMERGENCY LIGHTS AND EXIT SIGNS (CENTERED AT
10'-6" A.F.F. TO BE ABOVE FIXTURES & MERCHANDISE)
THROUGHOUT THE BLDG. IN COMPLIANCE WITH ALL
APPLICABLE CODES.
COORDINATE BUILDING SIGN SIZE WITH DOLLAR
GENERAL SIGN DEPARTMENT BY EMAILING TO
SIGNAGE@DOLLAR GENERAL.COM, LOCATE JBOX ON
INTERIOR OF PARAPET 13'-0" LEFT OF CENTER OF
SIGNBAND AREA B/23.
1/16" = 1'-0"
E-2
2 CABLE TRAY PLAN AND CONDUIT DIAGRAM
LIGHTING WIRING NOTES
1. AN OCTAGON BOX MOUNTED ON TOP OF EACH FIXTURE,
WITH FIXTURE WIRING BROUGHT INTO THE BOX FOR
CONNECTION TO THE CORD.
2. A TWISTLOCK 20AMP 120 VOLT RECEPTACLE AND CORD
FOR ATTACHMENT AT THE STEEL TRUSS MOUNTED IN A
STEEL BOX DIRECTLY ABOVE EACH LIGHT FIXTURE, EACH
BOX CONNECTED WITH STEEL CONDUITS BETWEEN EACH
OTHER BOX AND A STEEL CONDUIT HOME RUN BACK TO
THE PANEL.
3. THE SHO CORD SHALL BE 2#12 AND #12 GROUND, ALL
COPPER, FED FROM A 20 AMP SINGLE POLE BREAKER. THE
CORD SHALL ONLY BE USED AS A DROP FROM THE
RECEPTACLE BOX AT BUILDING STEEL AND TERMINATE
INTO A STEEL OCTAGON BOX MOUNTED ON TOP OF EACH
FIXTURE. THE CORD WILL HANG STRAIGHT DOWN TO THE
FIXTURE FROM THE RECEPTACLE / MOUNTING BOX, IT
SHALL NOT BE DRAPED HORIZONTALLY ACROSS BUILDING
STEEL BEFORE HANGING DOWN TO THE FIXTURE.
LIGHTING GENERAL NOTES:
1. ALL NIGHT LIGHTS, EMERGENCY LIGHTS, AND
EXIT SIGNS SHALL BE WIRED AHEAD OF ALL
LOCAL SWITCHING TO LIGHTING CIRCUIT
INDICATED.
2. SALES AND RECEIVING LIGHTS TO BE MOUNTED
AT 11'-0" AFF.
3. REFER TO SHEET A-8 FOR LIGHT FIXTURE
ATTACHMENT DETAIL.
4. RECEIVING AREA LIGHTS TO BE SPACED
EVENLY BETWEEN FRONT AND REAR WALL OF
THE RECEIVING AREA.
5. EMERGENCY LIGHT FIXTURE 'K' TO BE MOUNTED
AT 10'-6" AFF, ABOVE SHEETROCK.
1. CABLE TRAY TO BE MOUNTED SUCH THAT
BOTTOM OF TRAY IS AT 11'-6" A.F.F.. REFER TO
ELECTRICAL DRAWINGS FOR ADDITIONAL
INFORMATION.
2. CABLE TRAY SYSTEM TO BE INSTALLED USING
FULL LENGTHS WITH MINIMAL CUTTING OF
SECTIONS. AREAS WHERE CUTTING MAY
REQUIRED ARE AS NOTED ON THE PLAN.
3. ELECTRICAL CONTRACTOR SHALL PROVIDE
AND INSTALL CABLE TRAY AND ALL CONDUITS
WITH PULL STRINGS AS NOTED.
CABLE TRAY GENERAL NOTES:
4" W x 2" H CABLE TRAY CLEAR ANODIZED
FINISH WITH A WHITE POLYMER LINER SLEEVE
30" WIDE CORNER RADIUS FITTING, 30" WIDE
TEE FITTING AND SPLICE KITS
(2) KEYLESS SPEED LINK STRANDED CABLES
WITH HOOKS AT Y END PER TRAY WITH PURLIN
CLIPS
SPECIFICATIONS:
LIGHT FIXTURE DESCRIPTION
TYPE
DESCRIPTION
WATTS
K
N
SYMB COUNT
14
4
F83
KE3
MANF PART #
J 2
46XSP-3CREE
CREE LED LIGHTING XSP WALL SCONCE,
LED, TYPE III, FULL CUT OFF
30
4' STRIP 30W LED.
MOUNT TOP OF LIGHTS AS INDICATED
ON PLAN. (PENDANT MOUNTING KITS
ORDERED SEPARATELY AS REQUIRED)
3
3
3
EMERGENCY LIGHT (2) HEADS
90 MIN. BATTERY BACK-UP
LED-90-2HLED-WPEXITRONIX
EMERGENCY LIGHT (2) HEADS
90 MIN. BATTERY BACK-UP
VLED-U-WH-EL90-2CLEDEXITRONIX
EMERGENCY LIGHT/EXIT COMBO (2)
HEADS 90 MIN. BATTERY BACK-UP
LED-90-BLANK-2HLEDEXITRONIX
LSG
LSPRO LBAR 48 CW 8030W FR MVOLT
NOTES:
1. ALL POWER POLES ARE TO BE ORDERED BLACK
IN COLOR.
2. ALL POWER POLE WHIPS TO BE 10'-0".
SCALE:
3
E3.1
NTS
FREEZER/COOLER POWER POLE
747DGS019-12'
COOLER POWER POLE
JUNCTION BOXES & PC1D3 &
PC1D4 (TWO CIRCUITS)
INSTALLED BY ELECTRICIAN
(ONE BLACK) 20 AMP
125/250v. NEMA #L-14-20 R
RECEPTACLE
COOLER/FREEZER POWER POLES
Cable kit for 120 volt cooler747DGS019
120 Volt 2 CIR. Power pole
747DGS019-12
125/250 volt Power pole with NEMA
L1420 connection
747DGS030-12
747DGS030
125/250 Cable kit for freezer
Qty. Power Pole DescriptionD&P Part No.
2
2
2
2
SINGLE CHANNEL
FOOT
BRACKET TO MOUNT
TO FLOOR
(2) 1E3-10 EXTENDER CABLE
AND CONNECTOR
SOLD SEPARATELY
(MODEL #747DGS030A)
POLE SECTION VIEW
POWER
CHANNEL
1.625"x2.125"
ID
DATA
CHANNEL
.75"x2.125"
ID
JUNCTION BOXES & PC1D3'S (TWO
CIRCUITS) INSTALLED BY
ELECTRICIAN
SINGLE CHANNEL
FOOT
BRACKET TO MOUNT
TO FLOOR
1E3-10 EXTENDER CABLE
AND CONNECTOR
SOLD SEPARATELY
(MODEL #747DGS019)
20 AMP 120 V.
DUPLEX REC.
POLE SECTION VIEW
POWER
CHANNEL
1.625"x2.125"
ID
DATA
CHANNEL
.75"x2.125"
ID
747DGS030-12'
FREEZER POWER POLE
2 1/4"
2 15/16"
2 1/4"
2 15/16"
747DGS020-12BK
(ONE BLACK) 20 AMP
125/250v. NEMA #L-14-20 R
RECEPTACLE
SINGLE CHANNEL
FOOT
BRACKET TO MOUNT
TO FLOOR
125/250 volt Power pole with NEMA
L1420 connection
747DGS030A 125/250 Cable kit for freezer
Qty. Power Pole DescriptionD&P Part No.
1
1
COOLER/FREEZER POWER POLE
120 Volt 1 CIR. Power pole
1 Cable kit for 120 volt cooler747DGS019A
COOLER/FREEZER POWER POLES
20 AMP 120 V.
DUPLEX REC.
(2) 1E3-10 EXTENDER CABLE
AND CONNECTOR
SOLD SEPARATELY
(MODEL #747DGS030)
(MODEL #747DGS019)
JUNCTION BOXES & PC1FS3 &
PC1FS4 (TWO CIRCUITS)
INSTALLED BY ELECTRICIAN
747DGS020-12BK
1 2 3 4 5
B
A
JOB NO.
D
C
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 FAX 330.572.2101
2016408.03
DO
LL
AR
G
EN
ER
AL
N.J. S
TA
TE
R
OU
TE
54 &
R
OU
TE
73
FO
LS
OM
(H
AM
MO
NT
ON
), N
J 08037
11.04.16
03.29.17
-
-
DA
TE
DE
SC
RIP
TIO
N
Dra
win
g N
am
e: O
:\2
01
6\2
01
64
08
\0
3 F
olso
m, N
J\D
wg
\B
ld
g\7
20
_E
3.1
_P
OW
ER
P
OL
E D
ET
AIL
S.D
WG
Ma
rch
2
9, 2
01
7 - a
ko
le
sa
r
E-3.1
PO
WE
R P
OL
E D
ET
AIL
S
MAR WCF
SCALE:
1
E-3.2
NTS
PHONE WIRING FOR REISTER
EXTRA WIRES TO BE WRAPPED AND
TAPED AROUND CABLE
ALL WIRES ARE CAT 5, 4-PAIR
USE SEPARATE RJ-11 JACKS FOR EACH
CONNECTION
RJ-11 JACK
BLUE
BLUE &
WHITE
BLU
E
BLU
E &
W
HIT
E
DMARC
LIN
E #3
LIN
E #2
LIN
E #1
PHONE LINE #1 LABEL AS "PHONE"
RJ-11 JACK: 1 - REGISTER
4
E-3.2
SCALE: NTS
REGISTER POWER POLE
SCALE:
2
E3.2
NTS
REGISTER ELECTRICAL DETAIL
REGISTER ELECTRICAL COMPONENTS
Qty. Power Pole DescriptionD&P Part No. National Account
Provider
B
R
B
R
B
R
1
2
1
2
GREEN/YELLOW=ISOLATED
GROUND
RED=HOT -
CIRCUIT 2
BLACK=HOT
- CIRCUIT 1
WHITE=NEUTRAL
GREEN=SHIELD
GROUND
747DGS023B
GREEN/YELLOW=ISOLATED
GROUND
RED=HOT -
CIRCUIT 2
BLACK=HOT
- CIRCUIT 1
WHITE=NEUTRAL
1D5-IG
GREEN
1D5-IG
GREEN
1D4
BROWN
1D4
BROWN
GREEN=GROUND
WHITE=NEUTRAL
BLACK=HOT -
CIRCUIT 1
RED=HOT -
CIRCUIT 2
747DGS023R
GREEN=GROUND
WHITE=NEUTRAL
BLACK=HOT -
CIRCUIT 1
RED=HOT -
CIRCUIT 2
GREEN=SHIELD
GROUND
12' 2CH Regular Pole W/2-C
& 1-D Connector DRW
#2004-12
Dual circuit power kit with
isolated ground
Dual circuit power kit
10' Cable Kit (Set of 4 whips)
747DGS023R
747DGS023B
1
1
1
1
D & P
D & P
POWER POLE
#747DGS044-126BK
OPEN CEILINGS OR
CEILINGS
HIGHER THAN 10'
WILL REQUIRE
HIGHER POWER
POLES
REG. POWER
(BY ELECTRICIAN)
747DGS032A
FOUR EACH 1E3-10
EXTENDER CABLE
AND CONNECTOR
SOLD SEPARATELY
(MODEL
#747DGS032A)
747DGS044-126BK
NOTES:
1. ALL POWER POLES ARE TO BE ORDERED BLACK
IN COLOR.
2. ALL POWER POLE WHIPS TO BE 10'-0".
*NOTE: BEFORE ORDERING AND INSTALLATION OF
ELECTRICAL COMPONENTS FOR REGISTERS, CONSULT
FINAL FIXTURE PLAN FOR NUMBER AND LOCATION.
MAXIMUM CIRCUITS FOR REGISTERS -
CIRCUITS AT MAIN REGISTER - (9) 110V
CIRCUITS AT ISLAND REGISTER - (3) 110V
BREAKERS FOR SHARED NEUTRAL CIRCUITS SHALL HAVE
HANDLE TIES OR 2-POLE CIRCUIT BREAKER.
1 2 3 4 5
B
A
JOB NO.
D
C
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 FAX 330.572.2101
2016408.03
DO
LL
AR
G
EN
ER
AL
N.J. S
TA
TE
R
OU
TE
54 &
R
OU
TE
73
FO
LS
OM
(H
AM
MO
NT
ON
), N
J 08037
11.04.16
03.29.17
-
-
DA
TE
DE
SC
RIP
TIO
N
Dra
win
g N
am
e: O
:\2
01
6\2
01
64
08
\0
3 F
olso
m, N
J\D
wg
\B
ld
g\7
25
_E
3.2
_P
OW
ER
P
OL
E D
ET
AIL
S.D
WG
Ma
rch
2
9, 2
01
7 - a
ko
le
sa
r
E-3.2
PO
WE
R P
OL
E D
ET
AIL
S
MAR WCF
1 2 3 4 5
B
A
JOB NO.
D
C
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 FAX 330.572.2101
2016408.03
DO
LL
AR
G
EN
ER
AL
N.J. S
TA
TE
R
OU
TE
54 &
R
OU
TE
73
FO
LS
OM
(H
AM
MO
NT
ON
), N
J 08037
11.04.16
03.29.17
-
-
DA
TE
DE
SC
RIP
TIO
N
Dra
win
g N
am
e: O
:\2
01
6\2
01
64
08
\0
3 F
olso
m, N
J\D
wg
\B
ld
g\7
50
_E
5_
EL
EC
TR
IC
AL
P
AN
EL
C
RIT
ER
IA
.d
wg
---- - a
ko
le
sa
r
E-5
EL
EC
TR
IC
AL
P
AN
EL
CR
IT
ER
IA
MAR WCF
PANEL A NOTES:
1. PANEL A TO BE SERVICE ENTRANCE SERIES RATED WITH AIC RATING OF 65K AIC MAIN AND USING 22K AIC BRANCH
BREAKERS (CONFIRM WITH UTILITY).
2. BREAKERS FOR HVAC UNITS SHALL BE SIZED PER MANUFACTURER REQUIREMENTS.
3. BREAKERS THAT SERVICE HVAC EQUIPMENT AND MOTOR LOADS (COOLERS, FREEZERS, ETC) TO BE HACR.
2
N.T.S.
SERVICE GROUNDING ELECTRODE
SYSTEM WIRING DIAGRAM
7
3
8
5
14
13
12
109
10
11
6
11
18
15
21
4
17
22
11
1
21
20
1
E-5
23
SERVICE GROUNDING DETAIL KEYNOTES:
1. #2/0 AWG GROUNDING ELECTRODE CONDUCTOR CONNECTED TO AN APPROVED
GROUNDING ELECTRODE.
2. NOT USED.
3. SERVICE ENTRANCE CONDUCTORS WITH GROUNDED (NEUTRAL) CONDUCTOR.
4. #2/0 AWG MAIN BONDING JUMPER.
5. UNDERGROUND METAL WATER LINE IN DIRECT CONTACT WITH EARTH FOR AT
LEAST 10'.
6. #6 SOLID COPPER GROUNDING JUMPER TO BE TERMINATED ON TELEPHONE
BACKBOARD.
7. INCOMING SERVICE FROM UTILITY COMPANY TRANSFORMER WITH SECONDARY
GROUNDED PER UTILITY COMPANY REQUIREMENTS.
8. GROUNDING JUMPER AROUND METER AND ANY NONMETALLIC PIPE SECTIONS.
9. UNDERGROUND METAL GAS LINE IN DIRECT CONTACT WITH EARTH FOR AT LEAST
10'. PROVIDE BONDING JUMPER AROUND GAS METER AND ANY NONMETALLIC
PIPE SECTIONS TO BOND METAL PIPING TO GROUNDING SYSTEM PER NEC
250.104(B).
10. CONNECTION SHALL MADE WITHIN 5' OF BUILDING ENTRANCE.
11. CADWELD EXOTHERMIC CONNECTION (TYPICAL).
12. EFFECTIVELY GROUNDED BUILDING STEEL COLUMN.
13. STEEL BASE PLATE.
14. BASE PLATE NUT AND ANCHOR BOLT INTO REINFORCED CONCRETE PIER OR
FOOTING. ANCHOR BOLT BONDED TO CONCRETE REINFORCING.
15. MAIN SERVICE SWITCH OR DISTRIBUTION PANELBOARD.
16. NOT USED.
17. ENCLOSURE GROUND.
18. CONCRETE-ENCASED ELECTRODE (REBAR) AS REQUIRED BY NEC 250.52.
19. BOND CONCRETE-ENCASED ELECTRODE (REBAR) TO BUILDING STEEL WITH #4
AWG PER NEC 250.53.
20. BOND SUPPLEMENTAL ELECTRODE TO THE GROUNDING ELECTRODE SYSTEM
WITH #2/0 AWG PER NEC 250.53.
21. BONDING JUMPER BONDED TO SYSTEM AND TO OTHER POINTS AND EQUIPMENT
AS REQUIRED BY NEC ARTICLE 250.
22. 10' X 3/4" COPPER CLAD GROUND ROD IN EARTH. QUANTITY AS REQUIRED TO
MEET OR EXCEED NEC 250.56 OR AS OTHERWISE STATED ON THE DRAWINGS
AND/OR SPECIFICATIONS WHICHEVER IS MORE RESTRICTIVE.
23. BOND METAL VENEER TO BUILDING STEEL WITH #6 AWG. BOND TO COMPLY WITH
OBC CHAPTER 27, PER SECTION 1405.10.4 OBC.
-
GENERAL PANEL NOTE:
1. ALL BREAKER LABELS TO BE TYPED/PRINTED. NO HAND WRITTEN
LABELS PERMITTED.
19
PROVIDE 3-POLE
BREAKERS AND
HANDLE TIE BOTH
3-POLE BREAKERS
TOGETHER TO
SATISFY NEC 210.7.
NEUTRAL MAY BE
SHARED WITH
3-POLE BREAKER.
PANEL B NOTES:
1. PANEL B SERIES RATED WITH PANEL A.
2. FURNISH & INSTALL 1 AND 2 POLE BREAKERS FOR COOLERS/FREEZERS AS PER FINAL FIXTURE
PLAN. RATING WILL NOT EXCEED 40 AMPS ON DOUBLE POLE BREAKERS. SINGLE POLE CIRCUITS
WILL NOT EXCEED 30 AMPS. VERIFY FINAL REQUIREMENTS PRIOR TO ORDERING BREAKERS AND
WIRE.
3. BREAKERS FOR SHARED NEUTRAL CIRCUIT SHALL HAVE HANDLE TIES OR 2-POLE BREAKER.
ALUMINUM ALTERNATE FOR SERVICE ENTRANCE
CONDUCTORS.
TWO SETS OF 4#300 KCMIL ALUMINUM IN 4" CONDUITS
NOTES:
1. COORDINATE WITH UTILITY COMPANY OR AUTHORITY HAVING JURISDICTION REGARDING SERVICE & METERING. IF AN EXTERIOR DISC.
SWITCH IS REQUIRED BY EITHER THE UTILITY OR AUTHORITY HAVING JURISDICTION, THE EC SHALL FURNISH AND INSTALL PER UTILITY
CO. OR AUTHORITY HAVING JURISDICTION'S REQUIREMENTS.
2. VERIFY BONDING GROUND WIRE REQUIREMENTS WITH LOCAL INSPECTOR PRIOR TO BIDDING.
3. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY AND CALCULATE SHORT CIRCUIT FAULT CURRENT AND ARC FLASH, AND
PROVIDE LABELS ON ELECTRICAL EQUIMENT PER N.E.C. AND LOCAL JURISDICTION.
4. THE SERIES RATED COMBINATION BREAKERS SHALL BE SELECTED BY A PROFESSIONAL ENGINEER BY THE VENDOR, AND A DOCUMENT
STAMPED & SIGNED BY SAME PRESENTED TO BOTH THE OWNER AND GPD GROUP.
(4)#600 KCMIL IN 4" CONDUITS
TRENCHING AND BACKFILL BY E.C.,
COMPLY WITH N.E.C TABLE 300.5.
UTILITY METER BY UTILITY CO.
PROVIDE METER BASE
PER UTILITY COMPANY STANDARDS
PANEL
'A'
400A
MCB
C
±5'-0"
L
SECURE CONDUIT TO
EXTERIOR BUILDING WALL
PANEL
'B'
225A
MLO
4-#4/0 (1)#4 GND., (1)#4 ISO GND.,
IN 2" CONDUIT
PROVIDE SLIP-FITTER IF
REQUIRED BY LOCAL
JURISDICTION.
PAD MOUNTED
TRANSFORMER
INCOMING UTILITY
1
N.T.S.
E-5
ELECTRICAL PANEL SCHEMATIC
E.C. SHALL PROVIDE CT CABINET AND MOUNT ON
EXTERIOR WALL PER UTILITY COMPANY STANDARDS.
COORDINATE LOCATION WITH UTILITY COMPANY.
REFER TO THIS SHEET DETAIL
2/E-5 FOR COMPLETE GROUNDING
SYSTEM AND SIZES
NOTE: PLAN IS DIAGRAMIC ONLY!! HOLD
CONDUIT TIGHT TO EXPOSED MAIN GIRTS
AND RUN AS HIGH AS POSSIBLE ALONG
PERIMETER WALLS TO RECEIVING AREA.
@ 8'-0" A.F.F.
EMERSON PRE-
PROGRAMMED E2 CZ-100
CONTROLLER
"EMS PANEL", MTD. NEXT TO
ELECTRICAL PANELS, AS
CLOSE AS POSSIBLE.
ELECTRICAL PANELS
TS
TS
ST
ST
ST
AT
ST
OT
1
AT
AT
AT
RTU-1
RTU-2
RTU-3
RTU-4
TO RTU-1S
S
TS
1
TO RTU-2
TS
1
TO RTU-3
S
S
1
TO RTU-4
m
m
NOTE:
A. REFER TO SCHEDULE FOR GENERAL CONTRACTOR
RESPONSIBILITIES. E.C. MAY USE CABLE TRAY FOR LOW
VOLTAGE CABLES, SEE 2/E2 FOR CABLE TRAY PLAN.
B. RUN CONDUIT FROM SENSORS TO BOTTOM OF STRUCTURE.
TEMPERATURE SPACE
SENSOR
(809-6590) MTD. @ 8'-0" A.F.F.
SUPPLY TEMP (501-1121)
MTD. IN SUPPLY DUCT
OUTDOOR AIR TEMP
MTD. @ 8'-0" A.F.F.
BELDEN 8761 OR EQUIVALENT
(22AWG, 2C, STRANDED,
SHIELDED)
BELDEN 8761 OR EQUIVALENT
(22AWG, 2C, STRANDED,
SHIELDED)
BELDEN 8761 OR EQUIVALENT
(22AWG, 2C, STRANDED,
SHIELDED)
QTY.
QTY. ONE (1) PER HVAC UNIT.
QTY. ONE (1) PER HVAC UNIT
ZONE.
QTY. ONE (1) PER RECEIVING
ENTRY.
1
EMS
SUPPLIER
GENERAL
CONTRACTOR
EMS
SUPPLIER
GENERAL
CONTRACTOR
EMS
SUPPLIER
HVAC SUB
CONTRACTOR
VERIFY
VERIFY
AHU TERMINAL STRIP
AT
8C T-STAT CABLE QTY. ONE (1) PER HVAC UNIT.VERIFY
EMS
SUPPLIER
GENERAL
CONTRACTOR
RJ-11/RJ-45 DATA JACK,
PHONE COMBO.
24 GA., 4 TWISTED-PAIR,
CATEGORY-FIVE (CAT 5) DATA
CABLE .
QTY. ONE (1) AT OFFICE
COMPUTER CART.
1
GENERAL
CONTRACTOR
GENERAL
CONTRACTOR
DESCRIPTIONSYMBOL CABLE TYPE NOTES
SUPPLIED
BY:
INSTALLED
BY:
OT
ST
TS
S
MOTION SENSOR SWITCH.LEVITON EZ-FIND ODS-10-IDW
QTY. ONE (1) PER MEN'S
RESTROOM.
QTY. ONE (1) PER WOMEN'S
RESTROOM.
4
GENERAL
CONTRACTOR
GENERAL
CONTRACTOR
m
SENSOR PLAN KEYED NOTES
1
2
ALWAYS INSTALL THESE SENSORS AT 8'-0" A.F.F. THE EXACT
MOUNTING LOCATION OF THE HVAC SENSORS "TS" MAY
VARY DEPENDING ON THE STORE LAYOUT & DUCT
CONFIGURATION. REFER TO SITE SPECIFIC MECHANICAL
DRAWINGS FOR HVAC ZONED SENSOR MOUNTING
LOCATIONS. IF SENSORS ARE MOUNTED ON EXTERIOR
WALLS DUE TO DUCT CONFIGURATION, THEY ARE THEN TO
BE INSULATED TO PREVENT AIR INFILTRATION. IF ADDITIONAL
HVAC UNITS ARE USED, ADD ADDITIONAL TEMPERATURE
SENSORS "TS".
PHONE LINE #1 - TWO RJ-11 PORTS. ONE (1) LOCATED IN
OFFICE W/RJ-45 DATA JACK COMBO AND ONE (1) AT
REGISTER. 24 GA. CAT 5, 4-PAIR TWISTED WIRE ONLY. USE
BLUE AND BLUE & WHITE WIRES. HOOK TO LINE #1 TERMINAL
IN RJ-11 JACK EACH PHONE JACK TO HAVE DEDICATED,
SEPARATE HOME RUN TO DMARC. LABEL AS "PHONE" AT THE
DESTINATION AND AT DMARC. PHONE COMPANY PROVIDES
FINAL HOOK UP TO DMARC ONLY.PHONE LINE #2 - RJ-11
PHONE JACK SUPPLIED AND WIRED BY CONTRACTOR.
2
m
m
WOMENS
105
VESTIBULE
107
MENS
104
OFFICE
101
BREAK ROOM
100
HALLWAY
106
SALES AREA
102
RECIEVING AREA
103
1 2 3 4 5
B
A
JOB NO.
D
C
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 FAX 330.572.2101
2016408.03
DO
LL
AR
G
EN
ER
AL
N.J. S
TA
TE
R
OU
TE
54 &
R
OU
TE
73
FO
LS
OM
(H
AM
MO
NT
ON
), N
J 08037
11.04.16
03.29.17
-
-
DA
TE
DE
SC
RIP
TIO
N
Dra
win
g N
am
e: O
:\2
01
6\2
01
64
08
\0
3 F
olso
m, N
J\D
wg
\B
ld
g\7
60
_ E
MS
1-S
EN
SO
R L
OC
.d
wg
Ma
rch
2
9, 2
01
7 - a
ko
le
sa
r
EMS-1
SE
NS
OR
L
OC
AT
IO
N P
LA
N
MAR WCF
1/8" = 1'-0"
EMS-1
1 SENSOR LOCATION PLAN
ON
278 6 45 3 1
ON
278 6 45 3 1
ON
278 6 45 3 1
ON
278 6 45 3 1
ON
HVAC1 24Vac
HVAC1 Supply Fan
HVAC1 Heat1
HVAC1 Heat2
HVAC1 Cool1
HVAC1 Cool2
HVAC2 24Vac
HVAC2 Supply Fan
HVAC2 Heat1
HVAC2 Heat2
HVAC2 Cool1
HVAC2 Cool2
HVAC3 24Vac
HVAC3 Supply Fan
HVAC3 Heat1
HVAC3 Heat2
HVAC3 Cool1
HVAC3 Cool2
HVAC4 24Vac
HVAC4 Supply Fan
HVAC4 Heat1
HVAC4 Heat2
HVAC4 Cool1
HVAC4 Cool2
HVAC5 24Vac
HVAC5 Supply Fan
HVAC5 Heat1
HVAC5 Heat2
HVAC5 Cool1
HVAC5 Cool2
HVAC6 24Vac
HVAC6 Supply Fan
HVAC6 Heat1
HVAC6 Heat2
HVAC6 Cool1
HVAC6 Cool2
50VA
Dusk To Dawn
Outside Perimeter
Sign Lights
Lights
Lights
Receiving
& Night lights
70% Lights
30% Lights
70% Lights
C1
C2
C7
C8
C3
C4
C5
C6
Outside Perimeter
Lights
COM 485 OUT
JP
2
JP
3
JP
4
S2 FAILSAFE
AC
1
0V
AC
2
POWER
RS485
+0
V-
(24VAC)
J10(HHT)
CP
C P
AR
T#
23
7-3
00
6 V
ER
. 1
.0
0
S1 NETWORK
Rx
Tx
Status
General
OUT1 OUT7OUT4OUT3OUT2 OUT5 OUT6 OUT8
2 7 864 5312 7 864 531
ON
BOARD NO.:
ON
Normal Test
24vAC
120vAC
10VA
24VCT 24V
C
120
208240
80VA
PANEL/CIRCUIT
PANEL/CIRCUIT
DOOR SW FRONT
DOOR SW EM./EXIT
DOOR SW RECEIVING
AC#1 SPACE TEMP
AC#1 SUPPLY TEMP
HVAC Control Wires To Utilize
Standard 8 Conductor, 18 Ga.,
Color Coated. See Photo This
Sheet.
AC#2 SPACE TEMP
AC#2 SUPPLY TEMP
AC#3 SPACE TEMP
AC#3 SUPPLY TEMP
SPARE
OUTSIDE
TEMPERATURE
MOTION SENSOR
RECEIVING
AC#4 SPACE TEMP
AC#4 SUPPLY TEMP
AC#5 SPACE TEMP
AC#5 SUPPLY TEMP
COOLER TEMP.
AC#6 SPACE TEMP
AC#6 SUPPLY TEMP
COOLER TEMP.
FREEZER TEMP.
FREEZER TEMP.
FREEZER TEMP.
Se
nso
r
24
Va
c
Mo
tio
n
Se
nso
r
24
Va
c
Mo
tio
n
COPPER
CONDUCTORS ONLY
2 AMP, 250 VOLT
FAST BLOW BUSS
GMA-2A OR
EQUIVALENT
INPUT POWER: 24VAC, 15VA,
50/60 Hz CLASS 2 POWER
ONLY. OUTPUTS, EACH:
240VAC,1.2A MAX.
S2 FAILSAFE ON(UP) For N.C.
Outputs OFF(DOWN) For N.O. Outputs
ICE CREAM
FREEZER TEMP
DAIRY COOLER
TEMP
LUNCH MEAT
COOLER TEMP
MOTION SENSOR FRONT
(WIRE PER MFG. INSTRUCTIONS)
MU
LT
IF
LE
X 1616L
CP
C P
AR
T#810-3072
FO
R IN
PU
TS
1-8
FO
R IN
PU
TS
9-16
FO
R 16A
I B
OA
RD
FO
R 8R
O (2 U
sed)
S3-N
ET
WO
RK
AD
DR
ES
S, B
AU
D
S4-N
ET
WO
RK
AD
DR
ES
S, B
AU
D
S1-S
EN
SO
R T
YP
E
SE
LE
CT
S
2-S
EN
SO
R
TY
PE
S
ELE
CT
SENSOR
CONNECTIONS
16AI 1
8RO
1,2
237-3068 Ver.
1.00 1616
LAO/LDO
278 6 45 3 1
ON
278 6 45 3 1
ON
278 6 45 3 1
ON
278 6 45 3 1
ON
MU
LT
IF
LE
X 1616L
CP
C P
AR
T#810-3072
FO
R IN
PU
TS
1-8
FO
R IN
PU
TS
9-16
FO
R 16A
I B
OA
RD
FO
R 8R
O (2 U
sed)
S3-N
ET
WO
RK
AD
DR
ES
S, B
AU
D
S4-N
ET
WO
RK
AD
DR
ES
S, B
AU
D
S1-S
EN
SO
R T
YP
E
SE
LE
CT
S
2-S
EN
SO
R
TY
PE
S
ELE
CT
237-3068 Ver.
1.00 1616
LAO/LDO
B/13
B/15
B/5
B/7
B/9
B/11
B/27
B/29
B/23
B/25
B/1
B/3
EMS GENERAL NOTES
1. EMS SUPPLIER NOTE: CUSTOMIZED DOLLAR GENERAL
EMS PANEL REQUIRES STORE #, CITY, STATE, ZIP CODE
& QTY. OF HVAC UNITS OF THE INSTALL SITE WHEN
ORDERING. EMS SYSTEMS INSTALLATION GUIDE WITH
PHOTOS IS AVAILABLE ON NATIONAL ACCOUNT WEBSITE.
ALL QUESTIONS PERTAINING TO THE EMS PANEL,
SYSTEM INSTALLATION & SETUP SHOULD BE DIRECTED
TO EMERSON'S DOLLAR GENERAL SUPPORT TEAM AT
770-425-2724.
2. ALL SIGN & LIGHTING CIRCUITS MUST BE FED THROUGH
THE DESIGNATED CONTACTORS AS NOTED ON THIS
PAGE.
3. ALL LOW VOLTAGE HVAC & DOOR SENSORS MUST BE
CONNECTED TO THE PROPER TERMINAL. 24 GA.
SHIELDED (SHIELD MUST BE GROUNDED) CABLE, BELDEN
#8641, 2 CONDUCTOR WIRE OR IT'S EQUIVALENT IS
REQUIRED.
4. COOLER & FREEZER HOME RUNS WILL BE TERMINATED
AT ALL POINTS BY DOLLAR GENERAL REFRIGERATION
DEPARTMENT.
TESTING NOTES
TESTING OF HVAC UNITS THRU EMS PANEL IS
ACCOMPLISHED BY SIMPLY WARMING UP OR
COOLING DOWN A SPACE TEMPERATURE SENSOR
(USING A BLOW DRYER OR ELECTRONIC EQUIPMENT
DUSTER AEROSOL) AND WATCH THE FAN, HEAT AND
COOL STAGES CYCLE ON AND OFF. THIS REQUIRES
TWO PEOPLE AT ALL TIMES....ONE TO WATCH THE
SCREEN AND THE OTHER TO WATCH OPERATION OF
THE AHU. WHEN COMPLETE, PRESS THE HOME
BUTTON TO RETURN TO THE MAIN SCREEN.
NOTE:
EMS SYSTEM SHOULD BE TESTED FOR HVAC
OPERATION, INTERIOR LIGHTING, EXTERIOR LIGHTING
AND SIGN LIGHTING PRIOR TO CONTRACTOR'S
ELECTRICAL POSSESSION DATE. USE OUTSIDE LIGHT
AND SIGN LIGHT OVERRIDE FOR EXTERIOR TESTING.
GENERAL CONTRACTOR TO
ENSURE THAT THE BATTERY
ENABLE IS SWITCHED TO THE
"ON" POSITION
!
Inside lights override Sign light override
CAUTION!
Outside light override
Pre-Programmed e2 cx-100 Controller
!
Escalation Contact List
If you need HVAC Maintenance,
call 866-300-0004, option 1.
If you have Temperature Set Point
concerns, contact your District
Manager.
If you are having problems with
your Lights, call 866-300-0004,
option 6.
If you are having problems with
your Coolers, call 866-300-0004,
option 2.
If you are having problems with
your Sign, call 866-300-0004,
option 1.
If your store hours change, call
866-300-0004, option 6.
Verifying the Time and Date
From the Home screen.
1. The Date is in the upper left corner of the Home screen.
2. The Time is in the upper right corner of the Home screen.
HVAC Control Status
* Press the Home screen button.
* Select F1 AHU.
* Using the arrow keys, highlight the appropriated HVAC Unit, select enter.
* From the screen you can view:
i. Ctzl Temp (Control Temp - The sales floor temp).
ii. Values in [ ] represent the set point we are trying to maintain.
iii. Space Temp (Temperature at problem on Sales Floor).
iv. Supply Temp (Air Temp leaving AHU).
v. Status of Fan/Heat/Cools
* When complete, select the Home button.
Lighting Status
* The status of Store Lights can be viewed in the bottom left corner of the Home page, or by the following:
* Press the Home screen button.
* Select F2 Lighting.
* Highlight the appropriate Lighting Control, then select enter.
* When complete, select the Home button.
Refrigerated Case Status
* Case Temperature can be viewed from the Home screen.
To view a graph of the case temperature:
i. Highlight the Temp value and select enter.
ii. Select 1 for graph.
To zoom select F5 Zoom-In.
(Press F5 Zoom-In as many times as necessary, get to the desired scale/range).
(Use the left and right arrow keys to move to the time/date range desired).
* When complete, select the Home button.
Alarm Status
From the Home screen, select Alarm button.
1. Date: The date the alarm occured.
2. Time: The time the alarm occured.
3. State: Notice, Alarm or Fail.
* Notices are general warnings that notify a user of minor errors.
* Alarms are warnings about important system conditions that need immediate attention.
* Fails are high priority conditions, warning the user of a controller or device failure.
4. Property on Board and Point: The item that has generated the alarm.
5. Message: The description of the notice, alarm or fail.
a. Using the up or down arrow keys, highlight the appropriate alarm and select F4 Expd. Info.
i. Expd. Info: Expanded Information will give the unit & detailed status on the alarm.
ii. When finished viewing detailed status, select enter.
* When complete, select the Home button.
Load licenses if
applicable
528-5134
528-5096
Load E2 Setpoints
file Load IP address
information
All power must be shut
off prior to wiring,
installation, or service.
More than one
disconnect may be
required to de-energize
this panel.
B/33
B/35
1
N.T.S.
CPU TERMINAL DIAGRAM
EMS-2
2
N.T.S.
PROGRAMMER CONTROLLER
EMS-2
3
N.T.S.
CONTROLLER WIRING DIAGRAM
EMS-2
1 2 3 4 5
B
A
JOB NO.
D
C
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 FAX 330.572.2101
2016408.03
DO
LL
AR
G
EN
ER
AL
N.J. S
TA
TE
R
OU
TE
54 &
R
OU
TE
73
FO
LS
OM
(H
AM
MO
NT
ON
), N
J 08037
11.04.16
03.29.17
-
-
DA
TE
DE
SC
RIP
TIO
N
Dra
win
g N
am
e: O
:\2
01
6\2
01
64
08
\0
3 F
olso
m, N
J\D
wg
\B
ld
g\7
70
_ E
MS
2-P
NL
C
NT
LS
.d
wg
Ma
rch
2
9, 2
01
7 - a
ko
le
sa
r
EMS-2
CP
U T
ER
MIN
AL
D
IA
GR
AM
,
EM
S P
AN
EL
&
C
ON
TR
OL
S
MAR WCF
FOR
REFERENCE
ONLY
(1) CIRCUIT FOR SITE LIGHTING
FIXTURES IN (1) 1" PVC SCH. 40
UNDERGROUND CONDUIT. CIRCUIT
SHALL BE (2)#8, (1)#8 GND. (CKT. B/27)
SCALE: 1/16" = 1'0"
UNDERGROUND
ELECTRIC AND
TELEPHONE
SERVICES,
COORDINATE
WITH UTILITY
COMPANIES.
PROPOSED
DOLLAR GENERAL
BUILDING
REFER TO SHEET E-5 FOR
ELECTRICAL SERVICE
INFORMATION.
(1) CIRCUIT FOR SITE
LIGHTING FIXTURES.
CIRCUIT SHALL BE
(2)#6, (1)#6 GND.
(CKT. B/29)
AND
(1) CIRCUIT FOR
PYLON SIGN.
CIRCUIT SHALL BE
(2)#8, (1)#8 GND.
(CKT. B/25)
IN (1) 1 1/2" PVC SCH.
40 UNDERGROUND
CONDUIT, SCH. 80
UNDER DRIVE AND
PARKING.
PROPOSED PAD MOUNTED TRANSFORMER.
COORDINATE FINAL LOCATION WITH UTILITY
COMPANY.
LUMINAIRE SCHEDULE
SYMBOL QTY LABEL DESCRIPTION ARRANGEMENT LUMENS LLF
2 XSP-3 SINGLE 4187CREE LED LIGHTING XSP WALL SCONCE, LED, TYPE 3.90
3
1
2
CREE LED LIGHTING OSQ SERIES, LED, TYPE 4OSQ-4-DBL
BACK-BACK
10895
.90
.90
.90
9124
9235
OSQ-4-HS
CREE LIGHTING OSQ SERIES, LED, TYPE 4
SINGLE
SINGLECREE LIGHTING OSQ SERIES, LED, TYPE 3OSQ-3-HS
1 2 3 4 5
B
A
JOB NO.
D
C
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 FAX 330.572.2101
2016408.03
DO
LL
AR
G
EN
ER
AL
N.J. S
TA
TE
R
OU
TE
54 &
R
OU
TE
73
FO
LS
OM
(H
AM
MO
NT
ON
), N
J 08037
11.04.16
03.29.17
-
-
DA
TE
DE
SC
RIP
TIO
N
Dra
win
g N
am
e: O
:\2
01
6\2
01
64
08
\0
3 F
olso
m, N
J\D
wg
\B
ld
g\8
10
_E
S1
_E
LE
CT
RIC
AL
S
IT
E L
IG
HT
IN
G P
LA
N.D
WG
Ma
rch
2
9, 2
01
7 - a
ko
le
sa
r
ES-1
EL
EC
TR
IC
AL
S
IT
E
PL
AN
MAR WCF
1/16" = 1'-0"
ES-1
1 ELECTRICAL SITE PLAN
SITE LIGHTING NOTES
1. FINAL SIGN CONNECTION AND UNDERGROUND CONDUIT IS LANDLORD
RESPONSIBILITY. PROVIDE CONDUIT FROM THE ELECTRICAL PANEL TO
LOCATION OF THE PYLON SIGN BASE. BURY CONDUIT UNDER PARKING AREA.
THE CONDUIT IS TO BE 1 1/2" AND HAVE ONE SET TO 8/2 WIRE WITH GROUND
AND A 20-AMP TWO POLE BREAKER AT THE PANEL. A TEMPORARY 3' TALL
STAKE SHALL BE PROVIDED TO DESIGNATE THE PYLON SIGN LOCATION UNTIL
THE SIGN IS PERMANENTLY INSTALLED. REMOVE POST AFTER SIGN IS
INSTALLED.
2. SITE / PARKING LOT LIGHTING: PROVIDE ADEQUATE POLE AND/OR WALL
LIGHTING FOR NIGHT VISION AROUND ENTRY, PARKING AND DUMPSTER PAD
AREAS.
3. MINIMUM OF TWO FOOT-CANDLES REQUIRED FOR ALL PAVED AREAS
EXCLUDING 15' PERIMETER FROM EDGE OF PAVEMENT.
4. REQUIRED LIGHTING: A COMBINATION OF POLE LIGHTS, BI-DIRECTIONAL
SECURITY LIGHTS AND WALL PACKS WILL BE USED. REFER TO ELECTRICAL
SITE PLAN AND SHEET E2 FOR ADDITIONAL INFORMATION.
5. PLEASE NOTE THAT LIGHTING DESIGN AND LAYOUT SHOULD BE SITE SPECIFIC
& MAY REQUIRE ADDITIONAL LIGHTING TO COMPLY WITH SITE DESIGN
CONDITIONS. THEREFORE, MAKE PROVISIONS FOR MORE POLE LIGHTING
WHEN A SPECIFIC SITE REQUIRES IT.
6. UNDERGROUND ELECTRICAL SHALL BE PROVIDED TO THE SITE LIGHT POLES.
7. WHERE LOCAL JURISDICTIONS DO NOT ALLOW DOLLAR GENERAL'S REQUIRED
LIGHTING PLAN, AN ALTERNATE SITE LIGHTING PLAN & PHOTOMETRIC PLAN
MUST BE SUBMITTED FOR APPROVAL TO THE DOLLAR GENERAL
AUTOCAD-STORE PLAN DEPARTMENT.
8. PHOTO METRIC SITE ANALYSIS AVAILABLE THROUGH DOLLAR GENERAL
VENDORS: ORION ENERGY SYSTEMS - BRENDAN HARTT 1-904-380-5033
9. DOLLAR GENERAL VENDOR PRICING FOR WALL PACKS OR POLE LIGHTING
AVAILABLE FROM: ORION ENERGY SYSTEMS - BRENDAN HARTT
1-904-380-5033 [email protected].
10. SEE SHEET E2 FOR MORE INFORMATION.
11. VERIFY LOCAL DARK SKY REQUIREMENTS AND CONTACT ORION ENERGY
SYSTEMS FOR APPROVED ALTERNATES IF REQUIRED.
12. CONTRACTOR SHALL COORDINATE WITH LOCAL JURISDICTION ON THE USE OF
LIGHT POLE HANDHOLES FOR J-BOXES. PROVIDE WP J-BOX IF REQUIRED AT
BOTH SIGN AND POLES.