Merchandising Applications
The above case model has case lengths that are UL and NSF approved.
Issue Date: 12/6/2012DX6HN -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 16.75 48.36 25.08 71.68 33.46 96.512 50.17 143.2
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves - One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves -One Row Canopy -
T8 Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity
1035 1118 1041 1124 11 19 11 19 +28°F +33°F 200-300 FPM
Add 13 BTUH/ft for additional LED canopy light
Electrical Data
Length (FT)
ECM Fan DataShelf Light
Amps Per Lighted Shelf
Nose Light Amps per
Lighted Shelf
Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row LED
2 Row T8
4 1 0.10 0.12 0.25 0.10 0.25 0.24 0.506 2 0.20 0.09 0.22 0.18 0.44 0.37 0.888 2 0.20 0.12 0.25 0.20 0.50 0.48 1.0012 4 0.40 0.12 0.25 0.36 0.75 0.72 1.50
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX6HN Cross View
Add 3” thickness for a pair of ends.
DX6HN Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 11/14/2012DX6LC -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 17.7 48.36 26.5 71.68 35.4 96.512 53.2 143.2
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
T8 Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity
1079 1165 1085 1172 11 19 11 19 +28°F +33°F 200-300 FPM
Electrical Data
Length ECM Fan Data Shelf Light - Amps Per
Lighted Shelf Nose Light - Amps Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row LED 2 Row T8
4’ 1 0.1 0.12 0.25 N/A N/A 0.24 0.56’ 2 0.2 0.09 0.22 N/A N/A 0.37 0.888’ 2 0.2 0.12 0.25 N/A N/A 0.48 1
12’ 4 0.4 0.12 0.25 N/A N/A 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX6LC Cross View
Add 3” thickness for a pair of ends.
DX6LC Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 11/14/2012DX6LD -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 19.76 49.538 39.48 98.9412 59.2 148.35
Refrigeration Data
BTUH per FT of Case Unlighted Shelves
LED Lights
BTUH per FT of Case Unlighted Shelves
T8 Lights Evap. Temp. Discharge Air
Parallel Single Parallel *Single Temp Velocity 256 276 297 321 +28°F +32°F 185 FPM
BTUH determined using EC Fan Motors.
Electrical Data
Length ECM Fan Data Light - Amps Anti-Sweat (101)
Fan Qty Amps T8 Gelcore LED Optimax Pro Amps4’ 1 0.1 0.96 0.16 0.16 0.618’ 2 0.2 1.44 0.28 0.33 1.2212’ 4 0.4 1.82 0.42 0.48 1.82
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 3 35 min +47°F
Glycol Data
Length Heat Load-BTUH Glycol % PG Supply Temp Temp Rise Flow Rate (GPM) Pressure Drop4’ 1,188 35 +20°F +12°F 0.217 0.30 PSI8’ 2,376 35 +20°F +12°F 0.434 0.30 PSI12’ 3,564 35 +20°F +12°F 0.650 0.30 PSI
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX6LD Cross View
Add 3” thickness for a pair of ends.
DX6LD Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 11/14/2012DX6LD-MCU -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 19.8 49.58 39.5 98.912 59.2 148.3
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves - One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves -One Row Canopy -
T8 Lights
Evap. Temp.
Discharge Air
Parallel Single * Parallel * Single Temp Velocity 256 276 * 297 * 321 +28°F +32°F 185 FPM
BTUH determined using EC Fan Motors.
Electrical Data
Length
ECM Fan Data Light - Amps Anti-Sweat
Condensate Pump *
Condensate Evaporator *
Minimum Circuit
Maximum Overcurrent
Fan Qty Amps * T8LED(Gel-core)
Amps Amps Amps Amps Amps
4’ 1 0.1 * 0.96 0.16 0.64 * 0.44 * 8.30 10.6 158’ 2 0.2 * 1.44 0.28 1.27 * 0.44 * 8.30 11.8 1512’ 4 0.4 * 1.82 0.42 1.82 * 0.44 * 8.30 13 20
Power Supply — 115V / 1 / 60
Length Compressor RLA
Compressor LRA
Condenser Fan Motor
Minimum Circuit
Ampacity
Maximum Overcurrent
Horse Power
4’ 4.2 16.8 0.6 6 10 1/38’ 5.7 24.1 0.7 8 10 1/212’ 5.7 24.1 0.7 8 10 1/2
Power Supply — 208V / 1 / 60
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 3 45 min +47°F
Type I refrigerator, intended for use in an area where the environ-mental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Re-frigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices with-out incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX6LD-MCU Cross View
Add 3” thickness for a pair of ends.
DX6LD-MCU Plan View
DX6LD
- Glycol - M
ulti-Deck
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75 deg F and 55% relative humidity. Kysor/Warren, whose policy is one of continuous improve-ment, reserves the right to change at any time, specifications, design or prices without incurring obligation.
Defrost Per Day Fail Safe Termination
Off Cycle 3 35 min +47°F
Issue: 5.22.2012 Kysor/Warren 5201 Transport Blvd 800-866-5596 phone www.kysorwarren.com Columbus, GA 31907 706-568-8990 fax
Defrost Data
Electrical Data
All electrical data based on 115V and unlighted shelves.
Capacities Length Facing Area (FT²) Cubic Capacity (FT³)
4’ 19.76 49.53
8’ 39.48 98.94
12’ 59.20 148.35
Refrigeration Data
BTUH/ft determined using ECM Fan Motors.
BTUH per FT of Case Unlighted Shelves
LED Lights
* BTUH per FT of CaseUnlighted Shelves
T8 Lights
Evap. Temp.
Discharge Air
Parallel Single * Parallel Single Temp Velocity
256 276 * 297 * 321 +28°F +32°F 185 FPM
Length ECM Fan Data Light - Amps
Fan Qty Amps * T8 Gelcore LED Optimax Pro Amps
4’ 1 0.10 * 0.96 0.16 0.16 0.61
8’ 2 0.20 * 1.44 0.28 0.33 1.22
12’ 4 0.40 * 1.82 0.42 0.48 1.82
Anti-Sweat (101)
The above case model has case lengths that are UL and NSF approved.
Glycol Data
Length Heat Load – BTUH
Glycol % PG Supply Temp (°F) Temp Rise (°F) Flow Rate
(GPM) Pressure
Drop (PSI)
4’ 1,188 35 +20 +12 0.217 0.30
8’ 2,376 35 +20 +12 0.434 0.30
12’ 3,564 35 +20 +12 0.650 0.80
* NOTE: Options are not available after January 1, 2012.
DX6LD
- Glycol - M
ulti-Deck
Add 3” thickness for a pair of ends.
Profile View
Floor Plan
SKIDRAIL
MINIMUM AIR SPACE
LE
G
LE
G
LE
G
LE
G
312 7
2912
48-1/8 (72-1/4)
42
43
29
24 (36)
712
24 (36)
18
512
96-1/4 (144-1/2)
ELECTRICAL ACCESS POINT REFRIGERATION PENETRATION
DRAIN CONNECTION(WITH TRAP RIGHT OR LEFT)
FRONT OF CASE
29STUB UPAREA
STANDARD KICKPLATE LOCATION (PLATINUM)
3
3
3912
35
- STANDARD KICKPLATE LOCATION (MODERN, CLASSIC)- OPTIONAL KICKPLATE LOCATION (PLATINUM)
SKIDRAIL
3
2178
1614
6
42
5958
80
AIR
SP
AC
E
3
4178
3478
29
29278
4234
16
2634
338
62 DOOR
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 11/14/2012DX6LN -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 18.7 48.36 28.1 71.68 37.4 96.512 56.2 143.2
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy - T8
Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity
1155 1249 1166 1260 11 19 11 19 +28°F +33°F 200-300 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data Shelf Light - Amps Per
Lighted Shelf Nose Light - Amps Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row LED 2 Row T8
4’ 1 0.1 0.12 0.25 0.1 0.25 0.24 0.56’ 2 0.2 0.09 0.22 0.18 0.44 0.37 0.888’ 2 0.2 0.12 0.25 0.2 0.5 0.48 1
12’ 4 0.4 0.12 0.25 0.36 0.75 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min* +47°F
The fail safe time may be extended to a maximum of 28 minutes to allow for store condition variations, refrigeration system variations, and heavy shopping traffic. If the fail safe time is extended, the termination temperature must remain at 47°F.
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX6LN Cross View
Add 3” thickness for a pair of ends.
DX6LN Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 6/21/2013DX6LN (Glycol) — STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 18.7 48.3
6 28.1 71.6
8 37.4 96.5
12 56.2 143.2
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy - T8
Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity
1155 1249 1166 1260 11 19 11 19 +28°F +33°F 200-300 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data Shelf Light - Amps
Per Lighted ShelfNose Light -
AmpsCanopy Light -
Amps
Qty Amps LED T8 LED T8 1 Row LED
2 Row T8
4’ 1 0.10 0.12 0.25 0.10 0.25 0.24 0.50
6’ 2 0.20 0.09 0.22 0.18 0.44 0.37 0.88
8’ 2 0.20 0.12 0.25 0.20 0.50 0.48 1.00
12’ 4 0.40 0.12 0.25 0.36 0.75 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 35 min* +47°F
Glycol Data
Length Heat Load – BTUH
Glycol % PG
Supply Temp (°F)
Temp Rise (°F)
Flow Rate (GPM)
Pressure Drop (PSI)
4’ 4,644 35 +22 +12 0.847 1.20
6’ 6,966 35 +22 +12 1.271 2.70
8’ 9,288 35 +22 +12 1.694 1.20
12’ 13,932 35 +22 +12 2.542 2.70
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained that condi-tions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improve-ment, reserves the right to change at any time specifications, designs, or prices with-out incurring obligation.
The fail safe time may be extended to a maximum of 45 minutes to allow for store condition variations, refrigeration system varia-tions, and heavy shopping traffic. If the fail safe time is extended, the termination temperature must remain at 47°F.
A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com
DX6LN Cross View
Add 3 1/2” thickness for a pair of ends.
DX6LN Plan View
Merchandising Applications
The above case model has case lengths that are UL and NSF approved.
Issue Date: 12/6/2012DX6LP -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 17.7 48.36 26.5 71.68 35.4 96.512 53.2 143.2
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves - One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves -One Row Canopy -
T8 Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity 1079 1165 1085 1172 11 19 11 19 +28°F +33°F 200-300 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length (FT)
ECM Fan DataShelf Light
Amps Per Lighted Shelf
Nose Light Amps per
Lighted Shelf
Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row LED
2 Row T8
4 1 0.10 0.12 0.25 N/A N/A 0.24 0.506 2 0.20 0.09 0.22 N/A N/A 0.37 0.888 2 0.20 0.12 0.25 N/A N/A 0.48 1.0012 4 0.40 0.12 0.25 N/A N/A 0.72 1.50
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX6LP Cross View
Add 3” thickness for a pair of ends.
DX6LP Plan View
Merchandising Applications
The above case model has case lengths that are UL and NSF approved.
Issue Date: 12/6/2012DX6LP (T5) -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 17.7 48.36 26.5 71.68 35.4 96.512 53.2 143.2
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves - One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves -One Row Canopy -
T8 Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity 1079 1165 1085 1172 11 19 11 19 +28°F +33°F 200-300 FPM
BTUH per FT of Case Unlighted Shelves -
One Row Canopy - Standard T5
BTUH per FT of Case Unlighted Shelves -
One Row Canopy - High Output T5Parallel Single Parallel Single1090 1178 1109 1198
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length (FT)
ECM Fan DataShelf Light
Amps Per Lighted Shelf
Nose Light Amps per
Lighted Shelf
Canopy Light - Amps Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row LED
2 Row T8
1 Row Stan-dard T5
1 Row High Output T5
4 1 0.10 0.12 0.25 0.10 0.25 0.24 0.50 0.23 0.456 2 0.20 0.09 0.22 0.18 0.44 0.37 0.88 0.35 0.658 2 0.20 0.12 0.25 0.20 0.50 0.48 1.00 0.46 0.9012 4 0.40 0.12 0.25 0.36 0.75 0.72 1.50 0.69 1.35
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX6LP Cross View
Add 3” thickness for a pair of ends.
DX6LP Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 11/14/2012DX6UD -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 19.76 49.538 39.48 98.9412 59.2 148.35
Refrigeration Data
BTUH per FT of Case Unlighted Shelves
LED Lights
BTUH per FT of Case Unlighted Shelves
T8 Lights Evap. Temp. Discharge Air
Parallel Single Parallel Single Temp Velocity 256 276 297 321 +28°F +32°F 185 FPM
BTUH determined using EC Fan Motors.
Electrical Data
Length ECM Fan Data Light - Amps Anti-Sweat (101)
Fan Qty Amps T8 Gelcore LED Optimax Pro Amps4’ 1 0.1 0.96 0.16 0.16 0.618’ 2 0.2 1.44 0.28 0.33 1.2212’ 4 0.4 1.82 0.42 0.48 1.82
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 3 35 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX6UD Cross View
Add 3” thickness for a pair of ends.
DX6UD Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 11/14/2012DX6UN -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 19.76 48.36 29.6 71.68 39.48 96.512 59.2 143.2
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves - One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves -One Row Canopy -
T8 Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity
1201 1297 1207 1304 11 19 11 19 +26°F +33°F 200-300 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data
Shelf Light Amps Per
Lighted Shelf
Canopy Light - Amps
Fan Qty Amps LED T8 1 Row LED
2 Row T8
4’ 1 0.1 0.12 0.25 0.24 0.56’ 2 0.2 0.09 0.22 0.37 0.888’ 2 0.2 0.12 0.25 0.48 112’ 4 0.4 0.12 0.25 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX6UN Cross View
Add 3” thickness for a pair of ends.
DX6UN Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 11/14/2012DX6XN -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 17.7 48.36 26.5 71.68 35.4 96.5
12 53.2 143.2
Refrigeration Data
BTUH per FT of Case
Unlighted ShelvesOne Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted ShelvesOne Row Canopy - T8
Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity
1079 1165 1085 1172 11 19 11 19 +28°F +33°F 200-300 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data Shelf Light - Amps Per
Lighted Shelf Nose Light - Amps Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row LED 2 Row T8
4’ 1 0.1 0.12 0.25 0.1 0.25 0.24 0.56’ 2 0.2 0.09 0.22 0.18 0.44 0.37 0.888’ 2 0.2 0.12 0.25 0.2 0.55 0.48 1
12’ 4 0.4 0.12 0.25 0.36 0.75 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F
The fail safe time may be extended to a maximum of 28 minutes to allow for store condition varia-tions, refrigeration system variations, and heavy shopping traffic. If the fail safe time is extended, the termina-tion temperature must remain at 47°F.
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX6XN Cross View
Add 3” thickness for a pair of ends.
DX6XN Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 6/21/2013DX6XN (Glycol) — STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 17.7 48.3
6 26.5 71.6
8 35.4 96.5
12 53.2 143.2
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy - T8
Lights
Add BTUH per FT per Row Lighted
Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity
1079 1165 1085 1172 11 19 11 19 +28°F +33°F 200-300 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data Shelf Light - Amps Per
Lighted Shelf Nose Light - Amps Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row LED 2 Row T8
4’ 1 0.10 0.12 0.25 0.10 0.25 0.24 0.50
6’ 2 0.20 0.09 0.22 0.18 0.44 0.37 0.88
8’ 2 0.20 0.12 0.25 0.20 0.55 0.48 1.00
12’ 4 0.40 0.12 0.25 0.36 0.75 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 35 min +47°F
Glycol Data
Length Heat Load – BTUH
Glycol % PG
Supply Temp (°F)
Temp Rise (°F)
Flow Rate (GPM)
Pressure Drop (PSI)
4’ 4,360 35 +22 +12 0.796 1.20
6’ 6,540 35 +22 +12 1.193 2.60
8’ 8,720 35 +22 +12 1.592 1.20
12’ 13,080 35 +22 +12 2.386 2.60
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained that condi-tions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improve-ment, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
The fail safe time may be extended to a maximum of 45 min-utes to allow for store condition variations, refrigeration system variations, and heavy shopping traffic. If the fail safe time is extended, the termination temperature must remain at 47°F.