Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1...

17

Transcript of Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1...

Page 1: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7
Page 2: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwg

FLOOR PLAN: DWG DATE:SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

FLOOR PLAN

1. All dimensions to exterior face of sheathing @exterior walls.

2. All wall studs are 2X4 unless otherwise noted.3. Bracing Method: CS-WSP (Continuous

Sheathing-Wood Structural Panel)

4. 12' rigid insulation shall be used aswater-resistive barrier per ESR-2142 Sect. 4.3.

All seams and joints to be taped with 278"

construction tape.5. Face of sheathing @ exterior walls to align with

face of masonry below.6. All window locations to be determined on site

unless otherwise dimensioned.7. All windows and doors to be covered by

porches and flashed.8. All windows and doors shall have an overall

U-Factor of .35 or less, and a SHGC of .30 orless.

9. Water resistant flooring shall be used inkitchen, bathroom(s), and laundry areas AND

w/in 3 feet of all exterior doors.10. Clothes dryer shall be exhausted directly to

outdoors.11. HVAC Return is shown for crawl location

ONLY. Attic return is above hall ceiling.

12. Trusses shall have a raised heel to ensure fullinstulation value and 12" overhangs.

13. Light gray -OR- light brown shingles to be used

on roof.14. Any building face within 10' of property line

requires protection behind aluminum & vinylsoffits per NCRC 2012 Section R703.11.3.

15. TERMITE TREATMENT: BORATE treatmentof all framing within 3' of foundation.

16. Insulation shall be installed per manf'rs specswith no substantial gaps, voids, compressions,or wind intrusion. Insulation and air barriershall be in physical contact with each other.

17. Provide min. of 20' X 10' concrete driveway

AND 4' sidewalk to front door.

18. Seal external cracks, joints, etc. aroundwindows and doors with caulking and installpest proof screens.

19. Water heater to be located in designatedcloset as shown; drain and drain pan shall beinstalled; drain shall lead directly to outdoors.

20. Drain and drain pan -OR- single throw supplyvalve shall be installed for clothes washer.

1

1. 2'-8"X4'-4"2. 2'-8" X 3'0"

Meets all egress and glazingrequirements per 2012 NC

RES BLDG Code

36" Exterior Metal Entry Door WindowsExterior Doors

(2) 2X4(2) 2X4

Windows/Doors (1)

Per NCRC 2012 Table

R502.5(3)

Exterior Walls - 2X4s @ 24" O.C.Interior Walls - 2X4s @ 24" O.C.* No interior load bearing walls

-OR- point loads. All trusses bearon exterior walls.

A

32" Exterior Metal Entry DoorB

24" Interior DoorC

32" Interior DoorD

18" Interior DoorE

30" Interior DoorF

G

H

28" Interior Door

I

36" Interior Door

J

36" Bi-hung Interior Door

K

48" Bi-hung Interior Door

60" Bi-hung Interior Door

DUPONT_90 RIGHT

10'

WASHDRYER

Heated: 1288 SF

Unheated: 164 SF (covered porches)

1

E

F

H

G

C

KI

HH

H H

1

1

1

1

111

221

C

C

G

G

11'-412" 8' 25'-41

2" 4'

5'

46'

11'-8"

3'-4"

11'-9"

9'-712" 2' 9'-81

2" 10'-512" 12'-41

2"

3'-11"

3'-11"

3'-4"

4'-114" 2'-11

4"

3'-4"

2'-1"

9'-4

1 2"

5'-912" 1'-4"

2'-812"

101 2"

5'-0

1 4"

5'-0

1 4"

3'-0

1 2"

2'-112"5'-8"2'-8"

28'

8'-43 4

"

28'

4'-1"

VINYL

RET. AIR; SEENOTE 11

2'-614

"

CLEAR3'-3"

FUT.D.W.

3" PVC SUB SLAB VENTILATIONTEE-SUGGESTED LOCATION

H.W.

A

26'

6'

34'

1 1

A

20'-212"

PROPOSED ELECTRICAL

PANEL LOCATION

10'-4"

11'-4"

8'-2"

2'-6"

2'-6"

6'-8"

3'-6"

19'-8"

(2) 2X10 BEAM E.S. OFPORCH (SETS INFROM PORCH EDGE)

6X6 TREATED POSTWITH POST BASE, TYP

CENTER LINE OF BOX BEAM(SETS IN FROM PORCH EDGE);GABLE TRUSS SHALL BEAR ONPOSTS ONLY

8"13'-4" 8"

8"

FEB 26, 2016

Page 3: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwg

FLOOR PLAN: DWG DATE:SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

ELEVATIONS-1 of 2

COLUMN CAP DETAIL3

HANDRAIL/GUARD RAIL DETAIL4

2

1. Shall comply with NCRC 2012 Edition Section(s) R311 and R3122. "Historic B" Foundation ONLY: Brick foundation on front of house/porch ONLY (See foundation plan for details)

DUPONT_90 RIGHT

10'

FRONT ELEVATION1

SIDE ELEVATION2

11 1

8'-1 12"

0'-0"

8'-1 12"

0'-0"

12

5

1 1

VINYL BOARD ANDBATTEN SIDING

INSTALLED OVER 716"

OSB, HOUSE WRAP

VINYL LAP SIDING W/ TRIM(TYP) INSTALLED OVER

WALL SHEATHING (INSTALLPER MANUFACTURERS

WRITTEN INSTRUCTIONS)

25 YR FIBERGLASS

SHINGLE CLASS ACERTAINTEED INSTALLED

OVER 716" OSB, 15# FELT(INSTALLED PER

MANUFACTURERSWRITTEN INSTRUCTIONS)

RIDGE VENT

WRAPPED PORCH BEAM& PAINTED

PRESSURE TREATED6X6, WRAPPED ANDPAINTED

NOTE: WOODEN HANDRAIL/GUARD RAIL AS REQUIRED, MUST MEET CODE.SEE DETAIL THIS PAGE

SEE DETAIL 3, THISPAGE (TYP)

1X

10

BLOCKS

614"

16" O.C.

CAPPLATE

1X6

COLUMN CAP

NOTE:CAULK

AROUND1X6 AT

COLUMN

OS

B

O

SBO

SB

GA

BLE

TR

US

S

2X6 DEADWOOD

12" SOFFIT

6X6 POST

38"

34"

J-CHANNEL

VINYLSHAKES

3 1/2"

3/4"

6X6 COL.ATTACHEDTO BEAM

THRU COL.CAP W/ (2)

3" SCREWSE.S. OFPOST

COL CAPATTACHEDTO 6X6

POST W/ (4)3" SCREWS VINYL PERFORATED SOFFIT

@ EAVES

SIDE ELEVATION2

1 1

8'-1 12"

0'-0" MAIN FIN. FLOOR

8'-1 12"

0'-0"

12

5 2X6 PORCH ROOF EXTENSION

ATTACHED TO ROOF TRUSSES,BUILT IN FIELD. SEE ENGINEEREDDOCUMENTS

1

25 YR. FIBERGLASS SINGLE CLASS

A CERTAINTEED INSTALLED OVER7

16" OSB, 15# FELT (INSTALL PERMANUFACTURERS WRITTEN

INSTRUCTIONS)

TREATED 2X4 GUARDRAIL

2X TREATEDHANDRAIL

4X4 TREATEDPOST ANCH. TO

BRICK STEP W/ 12"

Ø EMBED.

ANCHOR BOLT

TREATED 2X2& 2X6 PICKETS,5" O.C. TYP

FEB 26, 2016

Page 4: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwgFLOOR PLAN: DWG DATE:

SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

ELEVATIONS-2 of 2

3

SIDE ELEVATION1

25 YR. FIBERGLASS SINGLE CLASSA CERTAINTEED INSTALLED OVER

716" OSB, 15# FELT (INSTALL PER

MANUFACTURERS WRITTENINSTRUCTIONS)

8'-1 12"

0'-0"

RIDGE VENT

2X6 SIDE PORCH ROOF EXTENSIONATTACHED TO ROOF TRUSSES,

BUILT IN FIELD. SEE ENGINEERED

DOCUMENTS

MAIN FIN. FLOOR

VINYL LAP SIDING W/ TRIM (TYP)

INSTALLED OVER WALLSHEATHING (INSTALL PER

MANUFACTURERS WRITTENINSTRUCTIONS)

10'REAR ELEVATION

2

1

2

8'-1 12"

0'-0"

8'-1 12"

0'-0"

2

DUPONT_90 RIGHT

8'-1 12"

0'-0"MAIN FIN. FLOOR

8'-1 12"

0'-0"

12

5

1 1

FEB 26, 2016

Page 5: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwg

FLOOR PLAN: DWG DATE:SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

1. Keep foundation walls at least 12" tall to keepwood members off the ground.

2. Dig continuous footing under all foundationwalls; 8" minimum thickness.

3. All walls, including porches, must be insideset back lines.

4. No interior load bearing walls or point loads.All trusses bear on exterior walls. (

)5. Top of rowlock on porch to be approx. 4"

lower than top of house slab.6. 4" of 3,000 PSI fiber reinforced concrete, 10

mil. vapor barrier with min. 4" washed stone orequiv recycled concrete over compacted fill,R-5 rigid insulation-See Details.

7. Locate within 12" of eachcorner, both sides of exterior doors, and every6'-0" O.C. See Habitat "Cut Sheet" for splicelocations. Locate anchors within 12" eachside of splice.

8. Termite Treatment: Structure to be termitetreated with BORATE when framing iscomplete.

CEM.

BRICKHOUSE LENGTH

PORCHDEPTH

FTG. FTG. FTG.

TOP OF SLABFACE

BRICK

COMPACTED FILL TO SLAB

A B C

4" BLOCK

8" BLOCK

PORCH: 12" SLOPE

COMPACTEDFILL TO SLAB

ROWLOCK

FACEBRICK

8" BLOCK

12" BLOCK

GRADE

FACE BRICK

CEM. BRICK

12" BLOCK

NOT TO SCALE; FINAL GRADE DETERMINES FOUNDATION AND PORCH HEIGHTSSLAB-HISTORIC A

4DUPONT_90 RIGHT

10'

A

46'

28'

53'-10 14 "

BACK

PORCH

FACE BRICK, TOPCOURSE

5'

4'

ROWLOCK ONPORCH EDGES

13'-412"

TO C/L OF SIDE PORCH

8" BLOCK WALL BELOW GRADE;4X8X16 CMU & CEMENT BRICK

BEHIND FACE BRICK

13'-412"

C/L OF 40" ROWLOCKFOR 36" DOOR

BRICK STEPS TO GRADE, 4' WIDE, BOLTSPER SUPERVISOR (NOT SHOWN)

CEMENT BRICK ON TOPOF BLOCK FORMSLEDGE FOR SLAB

8"

1'-4"

C

13'TO C/L OF STEPS

ROWLOCK ON

PORCH EDGES

8" BLOCK WALLBEHIND FACE

BRICK

12" BLOCK WALLPROVIDES 4"

LEDGE FORPORCH

FRONT PORCH

B

4" LIP FOR PORCH

6'

26'

10'-9"C/L OF 40" ROWLOCK

FOR 36" DOOR

BRICK STEPS TO GRADE, 4'WIDE, BOLTS PER

SUPERVISOR (NOT SHOWN)

13'-4" 6'-8"

FEB 26, 2016

Page 6: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwg

FLOOR PLAN: DWG DATE:SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

1. Keep foundation walls at least 12" tall to keepwood members off the ground.

2. Dig continuous footing under all foundationwalls; 8" minimum thickness.

3. All walls, including porches, must be insideset back lines.

4. No interior load bearing walls or point loads.All trusses bear on exterior walls. (

)5. Top of rowlock on porch to be approx. 4"

lower than top of house slab.6. 4" of 3,000 PSI fiber reinforced concrete, 10

mil. vapor barrier with min. 4" washed stone orequiv recycled concrete over compacted fill,R-5 rigid insulation-See Details.

7. Locate within 12"of each corner, both sides of exterior doors,and a min. of every 32". See Habitat "CutSheet" for splice locations. Locate strapswithin 12" each side of splice. Must Meet

Code.

8. Front wall ONLY: Face brick w/ ladder type

joint reinforcement; 12" Ø threaded rod anchors,

12" from corners; 6'-0" O.C.; 15" min.embedment.

9. Termite Treatment: Structure to be termitetreated with BORATE when framing iscomplete.

HEADERBLOCK

HOUSE LENGTHPORCHDEPTH

FTG. FTG. FTG.

TOP OF SLAB

COMPACTED FILL TO SLAB

A B C

8" BLOCK

PORCH: 12" SLOPE

COMPACTED

FILL TO SLAB

ROWLOCK

FACEBRICK

8" BLOCK

12" BLOCK

GRADE

NOT TO SCALE; FINAL GRADE DETERMINES FOUNDATION AND PORCH HEIGHTS

FACE BRICK

CEM. BRICK

12" BLOCK

SLAB-HISTORIC B

5DUPONT_90 RIGHT

10'

46'

28'

BACK

PORCH

5'

4'

ROWLOCK ONPORCH EDGES

13'-412"

TO C/L OF SIDE PORCH

BRICK STEPS TO GRADE, 4' WIDE, BOLTSPER SUPERVISOR (NOT SHOWN)

8"

1'-4"

C

13'TO C/L OF STEPS

ROWLOCK ON

PORCH EDGES

8" BLOCK WALLBEHIND FACE

BRICK

12" BLOCK WALL PROVIDES4" LEDGE FOR PORCH

FRONT PORCH

B

4" LIP FOR PORCH

6'

26'

8" BLOCK WALL BELOW GRADE;HOLLOW HEADER BLOCK, TOP

COURSE, TYP

4'-1"C/L OF 40" ROWLOCK

FOR 36" DOOR

13'-412"

C/L OF 40" ROWLOCKFOR 36" DOOR

BRICK STEPS TO GRADE, 4'WIDE, BOLTS PER

SUPERVISOR (NOT SHOWN)

53'-10 14 "

6'-8"13'-4"

A

12" Ø THREADEDROD ANCHOR

FOOTING

FACE BRICK W/LADDER TYPEJOINT

REINFORCEMENTHOUSE SLAB

PORCH SLAB

FRONT WALL FOUNDATION DTL.1

NOT TO SCALE

FEB 26, 2016

Page 7: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

NOT TO SCALE; FINAL GRADE DETERMINES FOUNDATION AND PORCH HEIGHTS

1A B C D

TOP OF MONO SLABPORCH: 1

2" SLOPE

TOP OF SHEDSLAB

HOUSE LENGTH

BRICK/STONEVENEER (OPT)

PORCHDEPTH

COMPACTED FILL TO SLAB

GRADE

1

E

TOP OF MONO SLAB

10"

4"

REBARCOMPACTFILL

16"X16" BRICK COL

PRECAST COL CAP

12"Ø BOLT,PROJECT 7"ABOVE COL CAP

8" CMU FILLEDSOLID

Note:Top of cap = 43"above porch slab

1. Dig continuous footing under all foundationwalls; 8" minimum thickness, with (2) #4rebars, continuous, on supports, @ 4'-0" O.C.

max.2. All walls, including porches, must be inside

set back lines.3. See plan for thickened slab/load bearing

interior wall locations (if applicable): 10" deepx 18" wide minimum footing with (2) #4continuous rebar.

4. Top of rowlock on porch to be approx. 4"

lower than top of house slab.5. 4" of 3,000 PSI fiber reinforced concrete, 10

mil. vapor barrier with min. 4" washed stone orequiv recycled concrete over compacted fill,R-5 rigid insulation.

6. Locate within 12"of each corner, both sides of exterior doors,

and a minimum of every 32". See Habitatplans for splice locations. Locate straps within12" each side of splice.

7. Termite Treatment: Structure to be termitetreated with BORATE when framing iscomplete.

6SLAB-MONOLITHIC

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwg

FLOOR PLAN: DWG DATE:SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

DUPONT_90 RIGHT

10'

28'53'-10 1

4 "

13'-412"

C/L OF 40" THRESHOLDPROJECTION

FOR 36" DOOR

10'-9"C/L OF 40" THRESHOLD

PROJECTIONFOR 36" DOOR

26'

6'

13'-4"

B

C

D

1'-4"

46'

5'

4'

6'-8"

FEB 26, 2016

Page 8: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwg

FLOOR PLAN: DWG DATE:SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

1. Maintain minimum floor joist clearance of 18"to grade and minimum dropped girderclearance of 12" to grade.

2. Dig continuous footing under all foundationwalls; 8" minimum thickness.

3. All walls, including porches, must be insideset back lines.

4. No interior load bearing walls or point loads.All trusses bear on exterior walls. (

).5. Poured porches-porch floor foundation will be

two (2) brick courses plus a rowlock higher

than house foundation.6. Sill anchors/anchor bolt installation-6'-0" O.C.

& within 12" of corners, then doubled every12'.

7. Front wall ONLY: Face brick w/ 8" CMU

filled solid; 12" Ø rod anchors, 12" from corners;6'-0" O.C.; 15" min. embedment.

8. Foundation vents within 3' of corners.

9. Crawl space door-see Site Prep Supervisorfor location.

10. Termite Treatment: Structure to be termitetreated with BORATE when framing iscomplete ( ).

8" BLOCK

FTG.

WATERPROOFING

GRAVEL

1'X1'

NOT TO SCALE

HOUSE LENGTHPORCHDEPTH

FTG.FTG. FTG.

CENTER BEAM

A B C

8" PIERFILLEDSOLID

PORCH: 12" SLOPE

COMPACTEDFILL TO SLAB

ROWLOCK

FACEBRICK

8" BLOCK

12" BLOCK

GRADE

CEM. BRICK

4" SOLIDBLOCK

12" BLOCK

JUMBO

BRICK

NOT TO SCALE; FINAL GRADE DETERMINES FOUNDATION AND PORCH HEIGHTS

FTG.

D

8" BLOCK PIER

FILLED SOLID

CRAWL-HISTORIC B

7DUPONT_90 RIGHT

10'

C

13'TO C/L OF STEPS

ROWLOCK ONPORCH EDGES

8" BLOCK WALLBEHIND FACE BRICK

12" BLOCK WALL PROVIDES 4"

LEDGE FOR PORCH

FRONT PORCH

B

53'-10 14 "

6'-10" 6'-10" 6'-10" 6'-10" 6'-10"

12'-31 2"

2'

2'

**NOTE: PIER FOOTINGS CAN BE DUG AS SINGLE 20" TRENCH

MINIMUM PIER FOOTING THICKNESS: 8"

4" LIP FOR PORCH

8X16 PIER (TYP),DROPPED 2"

BACK

PORCH

13'-412"

TO C/L OF SIDE PORCH5'

4'

ROWLOCK ONPORCH EDGES8" BLOCK WALL (TYP)

1'-4"

D

28'

15'-8

1 2"

6'

26'

8"

13'-4"

46'

BRICK STEPS TO GRADE, 4'

WIDE, BOLTS PERSUPERVISOR (NOT SHOWN)

A

6'-8"

FEB 26, 2016

Page 9: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwg

FLOOR PLAN: DWG DATE:SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

1. Long walls that run parallel with joists need ajoist or blocking underneath. Place 2X10blocking @ 3'-0" O.C.; consider plumbing whenrunning extra joists

2. Dimensions are to outside face or block &

center of joist unless otherwise noted3. Use pressure treated lumber adjacent to all

foundation brick and block material

•••• "Historic B"

•• 2X10 floor joists--top edges flush withgirders & band joists;

; double 2X12 girders; 2X10 band joists

JOIST

8DUPONT_90 RIGHT

10'

WASHDRYER

25'-10"

13'

1'-4"TYP.

12'-414"

1'-8"

CLE

AR

1'-4"

SET THIS DBLJOIST TO INSIDE TO

CATCH WALL

DOUBLE 2X10 HEADER

33'

EXAMPLE OF JOIST UNDER WALLTHAT RUNS PARALLEL WITH JOIST

OUTSIDE FACE OF BAND

H.W.

OUTSIDE FACE OF BAND

11"

11"1'-4"TYP

EX

TR

A

DO

UB

LE

DO

UB

LE

FEB 26, 2016

Page 10: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwgFLOOR PLAN: DWG DATE:

SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

9

1. All dimensions to exterior face of sheathing @exterior walls.

2. All wall studs are 2X4 unless otherwise noted.3. Bracing Method: CS-WSP (Continuous

Sheathing-Wood Structural Panel)

4. 12' rigid insulation shall be used aswater-resistive barrier per ESR-2142 Sect. 4.3.

All seams and joints to be taped with 278"

construction tape.5. Face of sheathing @ exterior walls to align with

face of masonry below.6. All window locations to be determined on site

unless otherwise dimensioned.7. All windows and doors to be covered by

porches and flashed.8. All windows and doors shall have an overall

U-Factor of .35 or less, and a SHGC of .30 orless.

9. Water resistant flooring shall be used inkitchen, bathroom(s), and laundry areas AND

w/in 3 feet of all exterior doors.10. Clothes dryer shall be exhausted directly to

outdoors.11. HVAC Return is shown for crawl location

ONLY. Attic return is above hall ceiling.12. Trusses shall have a raised heel to ensure full

instulation value and 12" overhangs.13. Light gray -OR- light brown shingles to be used

on roof.14. Any building face within 10' of property line

requires protection behind aluminum & vinylsoffits per NCRC 2012 Section R703.11.3.

15. TERMITE TREATMENT: BORATE treatmentof all framing within 3' of foundation.

16. Insulation shall be installed per manf'rs specswith no substantial gaps, voids, compressions,or wind intrusion. Insulation and air barriershall be in physical contact with each other.

17. Provide min. of 20' X 10' concrete driveway

AND 4' sidewalk to front door.

18. Seal external cracks, joints, etc. aroundwindows and doors with caulking and installpest proof screens.

19. Water heater to be located in designatedcloset as shown; drain and drain pan shall beinstalled; drain shall lead directly to outdoors.

20. Drain and drain pan -OR- single throw supplyvalve shall be installed for clothes washer.

FLOOR PLAN

1. 2'-8"X4'-4"2. 2'-8" X 3'0"

Meets all egress and glazing

requirements per 2012 NCRES BLDG Code

36" Exterior Metal Entry Door WindowsExterior Doors

(2) 2X4(2) 2X4

Windows/Doors (1)

Per NCRC 2012 TableR502.5(3)

Exterior Walls - 2X4s @ 24" O.C.

Interior Walls - 2X4s @ 24" O.C.* No interior load bearing walls

-OR- point loads. All trusses bearon exterior walls.

A

32" Exterior Metal Entry DoorB

24" Interior DoorC

32" Interior DoorD

18" Interior DoorE

30" Interior DoorF

G

H

28" Interior Door

I

36" Interior Door

J

36" Bi-hung Interior Door

K

48" Bi-hung Interior Door

60" Bi-hung Interior Door

DUPONT_90 LEFT

10'

Heated: 1288 SFUnheated: 164 SF (covered porches)

1

E

F

H

G

C

KI

H H

HH

1

1

1

1

1 1 1

2 2 1

C

C

G

G

11'-412"8'25'-41

2"4'

5'

46'

11'-8"

3'-4"

11'-9"

9'-712"2'9'-81

2"10'-51

2"12'-41

2"

3'-11"

3'-11"

3'-4"

4'-114"2'-1

14"

3'-4"

2'-1"

9'-4

1 2"

5'-912"1'-4"

2'-812"

101 2"

5'-0

1 4"

5'-0

1 4"

3'-0

1 2"

2'-112" 5'-8" 2'-8"

28'

8'-43 4

"

28'

4'-1"

VINYL

RET. AIR; SEENOTE 11

2'-614"

CLEAR3'-3"

FUT.D.W.

A

26'

34'

11

A

20'-212"

PROPOSED ELECTRICAL

PANEL LOCATION

10'-4"

11'-4"

2'-6"

2'-6"

6'-8"

3'-6"

19'-8"

8'-2"

(2) 2X10 BEAM E.S. OF

PORCH (SETS INFROM PORCH EDGE)

6X6 TREATED POSTWITH POST BASE, TYP

CENTER LINE OF BOX BEAM(SETS IN FROM PORCH EDGE);

GABLE TRUSS SHALL BEAR ONPOSTS ONLY

DRYERWASH H.W.

8" 8"

8"

6'

3" PVC SUB SLAB VENTILATIONTEE-SUGGESTED LOCATION

FEB 26, 2016

Page 11: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwgFLOOR PLAN: DWG DATE:

SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

ELEVATIONS-1 of 2

COLUMN CAP DETAIL3

HANDRAIL/GUARD RAIL DETAIL4

10

1. Shall comply with NCRC 2012 Edition Section(s) R311 and R312

2. "Historic B" Foundation ONLY: Brick foundation on front of house/porch ONLY (See foundation plan for details)

DUPONT_90 LEFT

10'

FRONT ELEVATION1

SIDE ELEVATION2

1X

10

BLOCKS

614"

16" O.C.

CAPPLATE

1X6

COLUMN CAP

NOTE:CAULK

AROUND1X6 AT

COLUMN

OSB

O

SBO

SB

GA

BLE

TR

US

S

2X6 DEADWOOD

12" SOFFIT

6X6 POST

38"

34"

J-CHANNEL

VINYLSHAKES

3 1/2"

3/4"

6X6 COL.ATTACHEDTO BEAM

THRU COL.CAP W/ (2)3" SCREWSE.S. OF

POST

COL CAPATTACHEDTO 6X6

POST W/ (4)3" SCREWS

1 11

8'-1 12"

0'-0"

8'-1 12"

0'-0"

12

5

11

VINYL BOARD ANDBATTEN SIDING

INSTALLED OVER 716"

OSB, HOUSE WRAP

VINYL LAP SIDING W/ TRIM(TYP) INSTALLED OVER

WALL SHEATHING (INSTALLPER MANUFACTURERSWRITTEN INSTRUCTIONS)

25 YR FIBERGLASS

SHINGLE CLASS ACERTAINTEED INSTALLED

OVER 716" OSB, 15# FELT

(INSTALLED PER

MANUFACTURERSWRITTEN INSTRUCTIONS)

RIDGE VENT

WRAPPED PORCHBEAM & PAINTED

PRESSURE TREATED6X6, WRAPPED AND

PAINTED

NOTE: WOODEN HANDRAIL/GUARD RAIL AS REQUIRED, MUST MEET CODE.

SEE DETAIL THIS PAGE

SEE DETAIL 3, THISPAGE (TYP)

VINYL PERFORATED SOFFIT@ EAVES

11

8'-1 12"

0'-0"MAIN FIN. FLOOR

8'-1 12"

0'-0"

12

52X6 PORCH ROOF EXTENSIONATTACHED TO ROOF TRUSSES,

BUILT IN FIELD. SEE ENGINEERED

DOCUMENTS

1

25 YR. FIBERGLASS SINGLE CLASS

A CERTAINTEED INSTALLED OVER7

16" OSB, 15# FELT (INSTALL PERMANUFACTURERS WRITTENINSTRUCTIONS)

TREATED 2X4 GUARDRAIL

2X TREATEDHANDRAIL

4X4 TREATEDPOST ANCH. TO

BRICK STEP W/ 12"

Ø EMBED.

ANCHOR BOLT

TREATED 2X2& 2X6 PICKETS,

5" O.C. TYP

FEB 26, 2016

Page 12: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwgFLOOR PLAN: DWG DATE:

SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

ELEVATIONS-2 of 2

11

25 YR. FIBERGLASS SINGLE CLASSA CERTAINTEED INSTALLED OVER7

16" OSB, 15# FELT (INSTALL PERMANUFACTURERS WRITTENINSTRUCTIONS)

8'-1 12"

0'-0"

8'-1 12"

0'-0"

VINYL PERFORATED SOFFIT @

EAVES

RIDGE VENT

2X6 SIDE PORCH ROOF EXTENSIONATTACHED TO ROOF TRUSSES,BUILT IN FIELD. SEE ENGINEEREDDOCUMENTS

MAIN FIN. FLOOR

VINYL LAP SIDING W/ TRIM (TYP)

INSTALLED OVER WALLSHEATHING (INSTALL PERMANUFACTURERS WRITTEN

INSTRUCTIONS)

SIDE ELEVATION1

10'REAR ELEVATION

1

2

8'-1 12"

0'-0"

8'-1 12"

0'-0"

2

2

DUPONT_90 LEFT

12

5

11

FEB 26, 2016

Page 13: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

1. Keep foundation walls at least 12" tall to keepwood members off the ground.

2. Dig continuous footing under all foundationwalls; 8" minimum thickness.

3. All walls, including porches, must be insideset back lines.

4. No interior load bearing walls or point loads.All trusses bear on exterior walls. (

)5. Top of rowlock on porch to be approx. 4"

lower than top of house slab.6. 4" of 3,000 PSI fiber reinforced concrete, 10

mil. vapor barrier with min. 4" washed stone orequiv recycled concrete over compacted fill,R-5 rigid insulation-See Details.

7. Locate within 12" of eachcorner, both sides of exterior doors, and every6'-0" O.C. See Habitat "Cut Sheet" for splicelocations. Locate anchors within 12" eachside of splice.

8. Termite Treatment: Structure to be termitetreated with BORATE when framing iscomplete.

CEM.BRICK

HOUSE LENGTHPORCHDEPTH

FTG. FTG. FTG.

TOP OF SLABFACE

BRICK

COMPACTED FILL TO SLAB

A B C

4" BLOCK

8" BLOCK

PORCH: 12" SLOPE

COMPACTEDFILL TO SLAB

ROWLOCK

FACE

BRICK

8" BLOCK

12" BLOCK

GRADE

FACE BRICK

CEM. BRICK

12" BLOCK

NOT TO SCALE; FINAL GRADE DETERMINES FOUNDATION AND PORCH HEIGHTS

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwgFLOOR PLAN: DWG DATE:

SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

SLAB-HISTORIC A

12DUPONT_90 LEFT

10'

46'

28'

53'-1014"

BACK

PORCH

FACE BRICK, TOPCOURSE

5'

4'

ROWLOCK ONPORCH EDGES

13'-412"

TO C/L OF SIDE PORCH

8" BLOCK WALL BELOW GRADE;4X8X16 CMU & CEMENT BRICKBEHIND FACE BRICK

13'-412"

C/L OF 40" ROWLOCKFOR 36" DOOR

BRICK STEPS TO GRADE, 4' WIDE, BOLTSPER SUPERVISOR (NOT SHOWN)

CEMENT BRICK ON TOP

OF BLOCK FORMSLEDGE FOR SLAB

8"

1'-4"

C

13'

TO C/L OF STEPS

ROWLOCK ONPORCH EDGES

8" BLOCK WALLBEHIND FACE

BRICK

12" BLOCK WALLPROVIDES 4"LEDGE FORPORCH

FRONT PORCH

B

4" LIP FOR PORCH

6'

26'

10'-9"C/L OF 40" ROWLOCK

FOR 36" DOOR

BRICK STEPS TO GRADE, 4'WIDE, BOLTS PERSUPERVISOR (NOT SHOWN)

13'-4"6'-8"

A

FEB 26, 2016

Page 14: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

HEADERBLOCK

HOUSE LENGTHPORCHDEPTH

FTG. FTG. FTG.

TOP OF SLAB

COMPACTED FILL TO SLAB

A B C

8" BLOCK

PORCH: 12" SLOPE

COMPACTEDFILL TO SLAB

ROWLOCK

FACEBRICK

8" BLOCK

12" BLOCK

GRADE

NOT TO SCALE; FINAL GRADE DETERMINES FOUNDATION AND PORCH HEIGHTS

FACE BRICK

CEM. BRICK

12" BLOCK

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwgFLOOR PLAN: DWG DATE:

SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

SLAB-HISTORIC B

13

1. Keep foundation walls at least 12" tall to keepwood members off the ground.

2. Dig continuous footing under all foundationwalls; 8" minimum thickness.

3. All walls, including porches, must be insideset back lines.

4. No interior load bearing walls or point loads.All trusses bear on exterior walls. (

)5. Top of rowlock on porch to be approx. 4"

lower than top of house slab.6. 4" of 3,000 PSI fiber reinforced concrete, 10

mil. vapor barrier with min. 4" washed stone orequiv recycled concrete over compacted fill,R-5 rigid insulation-See Details.

7. Locate within 12"of each corner, both sides of exterior doors,and a min. of every 32". See Habitat "CutSheet" for splice locations. Locate strapswithin 12" each side of splice. Must Meet

Code.

8. Front wall ONLY: Face brick w/ ladder type

joint reinforcement; 12" Ø threaded rod anchors,

12" from corners; 6'-0" O.C.; 15" min.embedment.

9. Termite Treatment: Structure to be termitetreated with BORATE when framing iscomplete.

DUPONT_90 LEFT

10'

A

46'

28'

BACK

PORCH

5'

4'

ROWLOCK ONPORCH EDGES

13'-412"

TO C/L OF SIDE PORCH

BRICK STEPS TO GRADE, 4' WIDE, BOLTSPER SUPERVISOR (NOT SHOWN)

8"

1'-4"

C

13'

TO C/L OF STEPS

ROWLOCK ONPORCH EDGES

8" BLOCK WALLBEHIND FACE

BRICK

12" BLOCK WALL PROVIDES4" LEDGE FOR PORCH

FRONT PORCH

B

4" LIP FOR PORCH

6'

26'

8" BLOCK WALL BELOW GRADE;HOLLOW HEADER BLOCK, TOPCOURSE, TYP

4'-1"C/L OF 40" ROWLOCK

FOR 36" DOOR

13'-412"

C/L OF 40" ROWLOCKFOR 36" DOOR

BRICK STEPS TO GRADE, 4'WIDE, BOLTS PER

SUPERVISOR (NOT SHOWN)

53'-1014"

6'-8" 13'-4"

12" Ø THREADEDROD ANCHOR

FOOTING

FACE BRICK W/LADDER TYPEJOINT

REINFORCEMENTHOUSE SLAB

PORCH SLAB

FRONT WALL FOUNDATION DTL.1

NOT TO SCALE

FEB 26, 2016

Page 15: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

NOT TO SCALE; FINAL GRADE DETERMINES FOUNDATION AND PORCH HEIGHTS

1A B C D

TOP OF MONO SLABPORCH: 1

2" SLOPE

TOP OF SHEDSLAB

HOUSE LENGTH

BRICK/STONEVENEER (OPT)

PORCHDEPTH

COMPACTED FILL TO SLAB

GRADE

1

E

TOP OF MONO SLAB

10"

4"

REBARCOMPACTFILL

16"X16" BRICK COL

PRECAST COL CAP

12"Ø BOLT,PROJECT 7"

ABOVE COL CAP

8" CMU FILLEDSOLID

Note:Top of cap = 43"above porch slab

1. Dig continuous footing under all foundationwalls; 8" minimum thickness, with (2) #4rebars, continuous, on supports, @ 4'-0" O.C.max.

2. All walls, including porches, must be insideset back lines.

3. See plan for thickened slab/load bearing

interior wall locations (if applicable): 10" deepx 18" wide minimum footing with (2) #4continuous rebar.

4. Top of rowlock on porch to be approx. 4"

lower than top of house slab.5. 4" of 3,000 PSI fiber reinforced concrete, 10

mil. vapor barrier with min. 4" washed stone orequiv recycled concrete over compacted fill,R-5 rigid insulation.

6. Locate within 12"of each corner, both sides of exterior doors,

and a minimum of every 32". See Habitatplans for splice locations. Locate straps within12" each side of splice.

7. Termite Treatment: Structure to be termite

treated with BORATE when framing iscomplete.

SLAB-MONOLITHIC

14HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwgFLOOR PLAN: DWG DATE:

SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

DUPONT_90 LEFT

10'

28'

53'-1014"

13'-412"

C/L OF 40" THRESHOLDPROJECTION

FOR 36" DOOR

10'-9"C/L OF 40" THRESHOLD

PROJECTIONFOR 36" DOOR

26'

6'

13'-4"

B

C

D

1'-4"

46'

5'

4'

6'-8"

FEB 26, 2016

Page 16: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

HOUSE LENGTHPORCHDEPTH

FTG.FTG. FTG.

CENTER BEAM

A B C

8" PIERFILLEDSOLID

PORCH: 12" SLOPE

COMPACTEDFILL TO SLAB

ROWLOCK

FACEBRICK

8" BLOCK

12" BLOCK

GRADE

CEM. BRICK

4" SOLIDBLOCK

12" BLOCK

JUMBOBRICK

NOT TO SCALE; FINAL GRADE DETERMINES FOUNDATION AND PORCH HEIGHTS

FTG.

D

8" BLOCK PIER

FILLED SOLID

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwgFLOOR PLAN: DWG DATE:SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

CRAWL-HISTORIC B

1. Maintain minimum floor joist clearance of 18"to grade and minimum dropped girderclearance of 12" to grade.

2. Dig continuous footing under all foundationwalls; 8" minimum thickness.

3. All walls, including porches, must be insideset back lines.

4. No interior load bearing walls or point loads.All trusses bear on exterior walls. (

).5. Poured porches-porch floor foundation will be

two (2) brick courses plus a rowlock higher

than house foundation.6. Sill anchors/anchor bolt installation-6'-0" O.C.

& within 12" of corners, then doubled every12'.

7. Front wall ONLY: Face brick w/ 8" CMU

filled solid; 12" Ø rod anchors, 12" from corners;6'-0" O.C.; 15" min. embedment.

8. Foundation vents within 3' of corners.9. Crawl space door-see Site Prep Supervisor

for location.10. Termite Treatment: Structure to be termite

treated with BORATE when framing iscomplete ( ).

8" BLOCK

FTG.

WATERPROOFING

GRAVEL

1'X1'

NOT TO SCALE

15DUPONT_90 LEFT

10'

12" BLOCK WALL PROVIDES 4"LEDGE FOR PORCH

BRICK STEPS TO GRADE, 4'WIDE, BOLTS PER

SUPERVISOR (NOT SHOWN)

C

13'TO C/L OF STEPS

FRONT PORCH

B

53'-1014"

6'-10"6'-10"6'-10"6'-10"6'-10"

12'-31 2"

2'

2'

**NOTE: PIER FOOTINGS CAN BE DUG AS SINGLE 20" TRENCH MINIMUM PIER FOOTING THICKNESS: 8"

4" LIP FOR PORCH

8X16 PIER (TYP),DROPPED 2"

BACK

PORCH

13'-412"

TO C/L OF SIDE PORCH5'

4'

ROWLOCK ONPORCH EDGES 8" BLOCK WALL (TYP)

1'-4"

D

28'

15'-81 2"

6'

26'

8"

46'

A

6'-8"ROWLOCK ONPORCH EDGES

8" BLOCK WALLBEHIND FACE BRICK

13'-4"

FEB 26, 2016

Page 17: Dupont (90) Construction Set...dupont_90 right 10' front elevation 1 side elevation 2 1 1 1 8'-1 1 2" 0'-0" 8'-1 1 2" 0'-0" 12 5 1 1 vinyl board and batten siding installed over 7

HABITAT FOR HUMANITY CHARLOTTE

CONTACT: CARRIE MASTO [email protected]

FILE:Dupont_90_REVISED.dwgFLOOR PLAN: DWG DATE:

SHEET TITLE: PLOT DATE: Feb. 26, 16

Habitatfor HumanityCharlotte

R

SHEET #:

JOIST

1. Long walls that run parallel with joists need ajoist or blocking underneath. Place 2X10blocking @ 3'-0" O.C.; consider plumbing whenrunning extra joists

2. Dimensions are to outside face or block &center of joist unless otherwise noted

3. Use pressure treated lumber adjacent to allfoundation brick and block material

•••• "Historic B"

•• 2X10 floor joists--top edges flush withgirders & band joists;

; double 2X12 girders; 2X10 band joists

16DUPONT_90 LEFT

10'

25'-10"

13'

1'-4"TYP.

EX

TR

A

DO

UB

LE

12'-414"

1'-8"

CLE

AR

1'-4"

SET THIS DBLJOIST TO INSIDE TO

CATCH WALL

DOUBLE 2X10 HEADER

DO

UB

LE

33'

EXAMPLE OF JOIST UNDER WALLTHAT RUNS PARALLEL WITH JOIST

OUTSIDE FACE OF BAND

OUTSIDE FACE OF BAND

11"

11"1'-4"TYP

DRYERWASH H.W.