Ducted Split System - Inverter, Split and ... - Oregan Air new Ducted System line up incorporates...

8
Disclaimer The descriptions and specifications in this brochure are relevant as at the date of publication. In the interest of product development, LG Electronics reserves the right to carry out alterations and improvements to products and specifications. Future releases of products, accessories and parts for them may differ from, and may not be compatible with current versions. As it may be difficult to determine the exact nature of a product from its depiction in this brochure, LG Electronics strongly recommends that you confirm with your retailer that the product shown or described in this brochure meets your requirements before you purchase the product. Warranty Brief - All LG Electronics Air Conditioning Units are covered by a 5-Year Parts and Labour Warranty when used in Residential Applications. Commercial Applications attract a 2-Year Parts and Labour Warranty.* - Air Conditioning units carry an on-site warranty.* *Further conditions apply, see the Warranty Card for further information. Due to LG's policy of continuous improvement and innovation, some specifications may change without notice. Please check with your retailer / AC specialist prior to purchase. © LG Electronics Australia Pty., Ltd. Printed in Korea [January 2009 ] Conditions apply LG Electronics Changwon Facility Achieved ISO9001 Certification Under Series 9000 of International Standard Organization(ISO) Based on Quality Systems For Design & Manufacture of Air Conditioners, Hermetic Refrication Compressors. AUS-DU091 New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : 02-8805-4000 FAX : 02-8805-4201 Queensland 23 Terrace Place MURARRIE QLD 4172 PH : 07-3908-9000 FAX : 07-3399-4179 Victoria 3 John Deere Court, Parkwest Estate DERRIMUT VIC 3030 PH : 03-8369-0900 FAX : 03-9931-0677 South Australia 91 Transport Avenue NETLEY SA 5037 PH : 08-8238-0200 FAX : 08-8238-0299 Western Australia 18 Baile Road, CANNING VALE WA 6155 PH : 08-9350-0800 FAX : 08-9256-1959 Customer Information Centre is available 7 days from 7AM-7PM on 1800 544 357 (1800 LG HELP) SMS Fault call 0400 660 629 http://www.lge.com.au/airconditioning New Zealand Unit A, 38 Highbrooke Drive, East Tamaki, 2013 New Zealand Tel : +64 (09) 914 2444 Fax : +64 (09) 914 2441 Customer Service Helpline 0508 643 156 www.lge.co.nz http://www.lge.com.au/airconditioning 2008/2009 Ducted Split System Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG

Transcript of Ducted Split System - Inverter, Split and ... - Oregan Air new Ducted System line up incorporates...

Page 1: Ducted Split System - Inverter, Split and ... - Oregan Air new Ducted System line up incorporates ... An inverter compressor will vary its capacity in order to ... Ducted Split System

DisclaimerThe descriptions and specifications in this brochure are relevant as at the date of publication.In the interest of product development, LG Electronics reserves the right to carry out alterations and improvements toproducts and specifications. Future releases of products, accessories and parts for them may differ from, and may not becompatible with current versions. As it may be difficult to determine the exact nature of a product from its depiction in thisbrochure, LG Electronics strongly recommends that you confirm with your retailer that the product shown or described in thisbrochure meets your requirements before you purchase the product.

Warranty Brief- All LG Electronics Air Conditioning Units are covered by a 5-Year Parts and Labour Warranty when used in Residential

Applications. Commercial Applications attract a 2-Year Parts and Labour Warranty.*

- Air Conditioning units carry an on-site warranty.*

*Further conditions apply, see the Warranty Card for further information.

Due to LG's policy of continuous improvement and innovation, some specifications may change without notice. Please check with your retailer / AC specialist prior to purchase.

© LG Electronics Australia Pty., Ltd. Printed in Korea [January 2009 ]

Conditions apply

LG Electronics Changwon Facility Achieved ISO9001 Certification Under Series 9000 of

International Standard Organization(ISO) Based on Quality Systems For Design & Manufacture of

Air Conditioners, Hermetic Refrication Compressors.

AU

S-DU

091

New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766PH : 02-8805-4000 FAX : 02-8805-4201

Queensland 23 Terrace Place MURARRIE QLD 4172PH : 07-3908-9000 FAX : 07-3399-4179

Victoria 3 John Deere Court, Parkwest Estate DERRIMUT VIC 3030PH : 03-8369-0900 FAX : 03-9931-0677

South Australia 91 Transport Avenue NETLEY SA 5037 PH : 08-8238-0200 FAX : 08-8238-0299

Western Australia 18 Baile Road, CANNING VALE WA 6155PH : 08-9350-0800 FAX : 08-9256-1959

Customer Information Centre is available 7 days

from 7AM-7PM on 1800 544 357 (1800 LG HELP)

SMS Fault call 0400 660 629

http://www.lge.com.au/airconditioning

New Zealand

Unit A, 38 Highbrooke Drive, East Tamaki, 2013 New Zealand

Tel : +64 (09) 914 2444 Fax : +64 (09) 914 2441

Customer Service Helpline 0508 643 156

www.lge.co.nz

htt

p:/

/w

ww

.lg

e.c

om

.au

/a

irco

nd

itio

nin

g

2008/2009

Ducted Split SystemEnjoy Clean, Quiet , and Comfortable Air Condit ioning with LG

Page 2: Ducted Split System - Inverter, Split and ... - Oregan Air new Ducted System line up incorporates ... An inverter compressor will vary its capacity in order to ... Ducted Split System

1www.lge.com.au

Why buy LG Air Conditioners?

Deluxe Controller Option

1

2

Intelligent DesignEach LG air conditioner has been designed with the latest technologies to ensure optimum comfort.

Advancements in inverter technology mean our air conditioners are more energy efficient than non

inverter models and reliable & easy to install.

But air conditioners aren't just about technology. The air conditioner is a fixture in

the home and its appearance is just as important as a piece of furniture. That's why

our new Ducted System line up incorporates functionality with design. The optional

Deluxe Wall Controller comes in a sleek, modern design to suit the walls of even the

most stylish homes and it has a backlit touchscreen panel for user friendly

operation.

The beautiful design of the new Deluxe Controller adds a touch of elegance to any interior. It boasts

several stand out features such as a backlit LCD touch screen, a large and easy to read display, optional

easy wall control with optional integrated zone control feature

Wide Range3Over many years of development, the range of LG Air Conditioners has continued to grow and we now

have a range to suit almost all tastes, needs and budgets!

We have taken all that we have learnt in the residential market and applied it to our commercial products.

So not only do we provide air conditioned comfort in homes, but we also have air conditioning systems to

suit office blocks and other commercial structures. From small air conditioners for apartments to large

systems for Multi-Storey buildings, LG has an air conditioner for everyone.

En joy C lean , Quiet , and Comfortab le

A i r Condit ion ing with LG

LG is committed to bringing it's customers comfort and has

produced a large range of air conditioners that do just that. It’s all

about comfort in the home, and offering you the perfect harmony

of stylish design and smart technology that fits your life.

Whether it's just a small unit for the bedroom, a larger unit to help

keep you cool in your lounge room, or a system to cool the entire

house such as a Ducted or Multi-Split systems, LG has designed

stylish, smart, reliable and functional air conditioners designed to

help make Life good.

Page 3: Ducted Split System - Inverter, Split and ... - Oregan Air new Ducted System line up incorporates ... An inverter compressor will vary its capacity in order to ... Ducted Split System

Inverter Technology

Time

100%

Cpa

city Fixed Speed

Inverter

Energy Saving

Cooing Load

More Economical An inverter's capacity will fluctuate in order to match the air conditioning requirements, soan inverter can be more energy efficient than a fixed speed compressor, as it does not stopand start its motor continually.

More PowerfulWith a wider range of temperature modes for heating and cooling, the inverter is able tooperate in even the most extreme outdoor temperatures. An inverter compressor can alsooperate faster than conventional air conditioners thus allowing the air conditioner to reachthe set temperature faster and bring you comfort sooner.

Quick Cooling & HeatingInverter air conditioners can operate their compressors faster to give them more powerfulperformance. This results in being able to attain the desired temperature much faster inboth heating and cooling modes than conventional air conditioners.

More Comfortable When the air conditioner is initially activated to either heat or cool, the compressor willoperate at maximum speed to reach the desired temperature quickly. Once the desiredtemperature is achieved, unlike conventional air conditioners that turn the compressor onand off, LG inverter units adjust and constantly vary the compressor speed to maintain thedesired temperature with minimal fluctuation to ensure that your comfort is notcompromised.

Indo

or T

emp(

˚C)

Outdoor Temp(˚C)

10

18

30

32

-10 -5 24 43

Heating

Cooling

Tem

p

Time

SettingTemp.

Power

On On OnOff Off Off

Tem

p

Time

SettingTemp.

Power

Conventional Inverter

With the advancement of the inverter technology comes quieter, economicaland powerful air conditioning systems.

What is Inverter Technology?Inverter technology refers to the compressor within the outdoor unit of the air conditioner. The two most common types of

compressors are the fixed speed compressor and the variable speed (inverter) compressor. The fixed speed will run at 100% of its

capacity and will stop and start automatically to maintain the desired temperature.

An inverter compressor will vary its capacity in order to maintain a consistent temperature.

Tem

p

Time

Setting Temp.

50%Time of

Conventional

Conventional

INVERTER

3www.lge.com.au2 www.lge.com.au

LG's has a ducted air conditioning range to suit any type of home or office, that operates quietly andefficiently.

Model Line-upDucted Split System Model Name Capacity(kW) Refrigerant

Min Rating Max

Cooling: 3.20 8.00 9.60

Heating: 3.65 9.20 11.0

FIXEDSPEED

Ducted Split System

Outdoor Unit

FIXED SPEED

Indoor_ B30AWYN661Outdoor_ B30AWYUE61

Cooling: 4.10 9.90 11.85

Heating: 4.40 11.00 12.10

Indoor_ B36AWYN661Outdoor_ B36AWYUE61

Cooling: 4.92 12.3 14.1

Heating: 5.64 14.1 15.5

Indoor_ B42AWYN661Outdoor_ B42AWYU361

Cooling: 5.64 14.1 16.2

Heating: 6.32 15.8 17.4

Indoor_ B48AWYN761Outdoor_ B48AWYU361

Cooling: 6.40 16.0 17.6

Heating: 7.04 17.6 19.4

Indoor_ B55AWYN761Outdoor_ B55AWYU361

Cooling: 10.8 18.0 20.0

Heating: 12.0 21.0 22.4

Indoor_ B62UWYN881Outdoor_ B62UWYUY81

Cooling: 12.6 21.0 23.5

Heating: 14.1 23.5 26.3

Indoor_ B72UWYN881Outdoor_ B72UWYUW81

Cooling: 5.28

Heating: 5.28

Indoor_ LBNH1863BLOutdoor_ LBUH1863BL

Cooling: 6.87

Heating: 7.50

Indoor_ B24AHF-NH5Outdoor_ B24AHF-NH5

Cooling: 8.28

Heating: 8.40

Indoor_ B30AHYN661Outdoor_ B30AHYN661

Cooling: 9.90

Heating: 10.90

Indoor_ B36AHYN661Outdoor_ B36AHYN661

Cooling: 13.0

Heating: 13.5

Indoor_ B42AHYN781Outdoor_ B42AHYN781

18.0 kW 21.0 kW12.3~16.0 kW9.9 kW8.0kW

9.9 kW 13.0 kW8.28 kW6.87 kW5.28kW

Du

cte

d S

plit S

yste

m

Page 4: Ducted Split System - Inverter, Split and ... - Oregan Air new Ducted System line up incorporates ... An inverter compressor will vary its capacity in order to ... Ducted Split System

Deluxe Wall Controller (optional)LG’s Deluxe Backlit Wall Controller is designed to suit even the most stylish interior. The touchscreen panel allows you to controlthe room's temperature with simplicity and style. It even has a backlit display so you can see it in the dark.In homes with large floor areas, you can also have dual controls and can control up to 4 zone settings.

• Touch screen / LCD backlit • Room Temperature Display • Weekly program • Timer function • Child lock • 24-Hour ON/ OFF Timer in 1 hour intervals • TEST RUN Mode • Self-Diagnosis function • 3-Step Fan Speed selection • Operation Indication • Only 17mm thick • 2 Controllers can be connected to 1 indoor unit • Group and central control at the same time

Enables you to easily see the control settings. The largerdisplay allows you to program settings by simply touchingthe control.

LCD backlit display

Touch Screen PanelTodays homes demand elegance, state of the art technology andfunctionality. LG’s new touch screen wall control delivers these featuresin a stylish and easy to use control unit.

Modern Design

The new control allows you to control up to four differentareas of your home. One touch of each zone will set theindicator on/off.

Zone Control

Standard Wall Control (optional)The operator can set the timing function of the air conditioner for a period of one week.

• 24 Hour On/Off time in 1 hour intervals • TEST RUN Mode • Self-Diagnosis function • 3-Step Fan Speed selection • Operation Indication • Room Temperature Display • Only 20mm thick • Main/Sub setting of indoor units (For override function) • 2 Controllers can be connected to 1 indoor unit • Group and central control at the same time • Reservation (Simple/Sleep/On/Off/Weekly/Holiday)

RF (Radio Frequency) Remote Control (optional)The RF Remote control provides complete freedom to operate the Ducted System from various locations. By using radio frequency,

LG has eliminated the need for wires and has enabled communication of up to 20 metres away from the indoor unit, even through

walls and floors. The controller allows you to conveniently turn the unit on/off and adjust the temperature and fan speed. It can

easily be added to the system during installation and works in conjunction with wall and infra-red controllers.

The New display is 70% larger, allowing you to easily read thecontrol settings.

Wide LED and Larger Character Display

Allows you to easily adjust the temperature in a darkened room. Luminous Button

PQRFA0

PQRCUSA0PDRCUDB0

L G A I R C O N D I T I O N E R S

5www.lge.com.au4 www.lge.com.au

User Friendly Controller

Includes a variety of functions that allow you to control upto four zones. Program the controller to your desiredcomfort level with a touch of your finger. The new childlock setting prevents the settings from being tamperedwith.

Du

cte

d S

plit S

yste

m

Page 5: Ducted Split System - Inverter, Split and ... - Oregan Air new Ducted System line up incorporates ... An inverter compressor will vary its capacity in order to ... Ducted Split System

Cooling operation range 21OC -46OCHeating operation range -5OC -24OC

Integrated external safety tray

On Off

1 2 3 4

5 6 7 8

9 10 11 12

13 14 15 16

1 2 16

Controller#1

AC Smart#2

1 2 16

Controller#8

On Off

1 2 3 4

5 6 7 8

9 10 11 12

13 14 15 16

Connecting cable(1EA) will be supplied in an indoor unitas a basic option

PZCWRCG2

Du

cte

d S

plit S

yste

mL G A I R C O N D I T I O N E R S

7www.lge.com.au6 www.lge.com.au

GoldFin™‚ is an anti corrosive treatment on the surface of the heat exchanger in the outdoor unit. The treatment is designed to protect air conditioners from pollution and corrosive conditions and assists in the durability andlongevity of the unit. This technology is the ideal solution for harsh Australian outdoor conditions.

Salt Spray Test for 15 Days

LG Gold Fin™protected Aluminum

LG Gold Fin™Corrosion Resistance

After 15 Days After 15 Days

UncoatedAluminum

ConventionalStarting to corrode

[Test Standard : ASTM B-117, KS D9502]

Durable Coating (GoldFin™)

The operator can set the timer and program the air conditioner for a period of one week.

Weekly Program

Allows you to control the unit from different locations inthe home. You can install up to two controllers whichcommunicate with each other to replicate your chosensettings.

Dual Wall Control (optional)

conventional LG Fan and Housing

A lightweight polymer blower and housing makes air conditioning operation quieterand backup servicing more convenient. The new fan housing can be easily dismantledfor convenient servicing and maintenance. * Not available in B62UWYN881, B72UWYN881

Quiet Operation & Easy Servicing

Dual thermistor control provides the option to control temperature by referring to either of the dual temperature sensors. With the help ofthe slide switch at the back of the LCD wired remote controller, selection of the desired thermistor for controlling the unit can be achieved.One thermistor is in the Indoor unit & the other one is in the LCD wired remote.

Dual Thermistor Control

This enables you to link several products together that can then be controlled by one control device. A connecting line is linked to eachof the indoor units to enable communication. This control device can be used to control up to 16 indoor units

Group Control

LG units come with advanced control options, such as the centralcontroller, which is designed for commercial applications, wheremultiple units have been installed. This allows you control between 16-1024 air conditioning units, via 8 seperate controllers.

Central Controller (optional)

Our LG Air Conditioners (Cassetteand Concealed duct models) can beinstalled over a long distance(Max50m) and a High Elevation(30m),between indoor and outdoor units.

Auxiliary Drain Pump automatically drainswater. A standard drain-head height of up to800mm is possible, which helps create theideal solution for water drainage.

Long Distance, High Elevation Piping Drain Pump (Option)

This function prevents little hands from tampering with the control buttons on the unit. All the buttons on the indoor displaypanel will be blocked

Child Lock Function

With enhanced technology, LG developed inverter products that can operate across a widetemperature range. The air conditioners have an operational range of up to 46ºC for coolingand down to -10ºC for heating, so you can be comfortable whatever the temperatureoutside.*

* operational capacity varies depending on ambient temperature. Contact LG for more information.

Wide Operation Temperature (Inverter models only) *

To prevent any potential damage caused by moisture, LG air conditioners have a built in auxiliarysafety tray. * Not available in LBNH1863BL, B24AHF-NH5, B62UWYN881, B72UWYN881

Evaporator safety tray* 700mm: 5.28/6.87/18/21kW, 800mm: 8.0~16kW

Refer to each model PDB for the height.

Pipe fixture

FlexibleDrain Hose

Drain pump

Wall

Drain pip

700mm or 800mm

Ducted Split System

Page 6: Ducted Split System - Inverter, Split and ... - Oregan Air new Ducted System line up incorporates ... An inverter compressor will vary its capacity in order to ... Ducted Split System

Du

cte

d S

plit S

yste

m

Ducted Split System

Inverter

Inverter

Inverter

Fixed

Fixed

Reverse Cycle

• Durable Coating • Weekly Program • Child Lock Function • Ez Tuning • Auto Restart • Standard Wall Controller_PDRCUSZ0 (Basic) • Long Distance(50m)/High Elevation(30m)

Option: • RF Controller PQRFA0• Group Control • Central Controller • Drain Pump

LBNH1863BL 5.28/5.28 2.51/2.80 38/36/34 | 55 880x260x450

B24AHF-NH5 6.87/7.50 2.64/2.77 42/40/38 | 52 880x260x450

Sound Pressure(dB(A)±3)Indoor(H/M/L) | Outdoor(H)

Capacity(kW)Cooling / Heating

EER/COP(W/W)Cooling / Heating

FIXEDSPEED

Dimension(mm)Model

L G A I R C O N D I T I O N E R S

Reverse Cycle

• Durable Coating • Weekly Program • Child Lock Function • Two Thermistor Control • Evaporate safety tray • Auto Restart • Long Distance(50m)/High Elevation(30m)

Option: • LCD Deluxe Wall Controller_PDRCUDB0 • Standard Wall Controller PQRCUSA0 • RF Controller PQRFA0 • Zone Control • Dual Wall Control • Group Control • Central Controller • Drain Pump

Sound Pressure(dB(A)±3)Indoor(H/M/L) | Outdoor(H)

Capacity(kW)Cooling / Heating

EER/COP(W/W)Cooling / Heating

B30AWYN661 Min : 3.20/3.65Rating : 8.00/9.20 2.62/3.29 44/41/39 | 51 1020x400x534Max : 9.60/11.00

B36AWYN661 Min : 4.10/4.40Rating : 9.90/11.00 2.71/3.06 45/43/41 | 56 1020x400x534Max : 11.85/12.10

B42AWYN661 Min : 4.92/5.64Rating : 12.30/14.10 2.72/3.00 47/45/42 | 55 1020x400x534Max : 14.10/15.50

Dimension(mm)Model

• Durable Coating • Weekly Program • Child Lock Function • Two Thermistor Control • Evaporate safety tray • Auto Restart • Long Distance(50m)/High Elevation(30m)

Option: • LCD Deluxe Wall Controller_PDRCUDB0 • Standard Wall Controller PQRCUSA0 • RF Controller PQRFA0 • Zone Control • Dual Wall Control • Group Control • Central Controller • Drain Pump

Reverse Cycle

Sound Pressure(dB(A)±3)Indoor(H/M/L) | Outdoor(H)

Capacity(kW)Cooling / Heating

EER/COP(W/W)Cooling / Heating

B48AWYN761 Min : 5.64/6.32Rating : 14.10/15.80 2.82/3.36 51/48/45 | 57 1320x400x534Max : 16.20/17.40

B55AWYN761 Min : 6.40/7.04Rating : 16.00/17.60 2.74/3.26 51/48/45 | 55 1320x400x534Max : 17.60/19.40

Dimension(mm)Model

Reverse Cycle

• Durable Coating • Weekly Program • Child Lock Function • Two Thermistor Control • Auto Restart • Long Distance(50m)/High Elevation(30m • Ez Tuning

Option: • LCD Deluxe Wall Controller_PDRCUDB0 • Standard Wall Controller PQRCUSA0 • RF Controller PQRFA0 • Zone Control • Dual Wall Control • Group Control • Central Controller • Drain Pump

Sound Pressure(dB(A)±3)Indoor(H/M/L) | Outdoor(H)

Capacity(kW)Cooling / Heating

EER/COP(W/W)Cooling / Heating

B62UWYN881 Min : 10.80/12.00Rating : 18.00/21.00 2.95/2.92 50/49/47 | 57 1562x460x688Max : 20.00/22.40

B72UWYN881 Min : 12.60/14.10Rating : 21.00/23.50 3.20/3.13 52/50/49 | 59 1562x460x688Max : 23.50/26.30

Dimension(mm)Model

Reverse Cycle

• Durable Coating • Weekly Program • Child Lock Function • Two Thermistor Control • Evaporate safety tray • Auto Restart • Long Distance(50m)/High Elevation(30m)

Option: • LCD Deluxe Wall Controller PDRCUDB0 • Standard Wall Controller PQRCUSA0 • RF Controller PQRFA0 • Zone Control • Dual Wall Control • Group Control • Central Controller • Drain Pump

B30AHYN661 8.28/8.40 2.63/2.95 44/41/39 | 58 1020x400x534

B36AHYN661 9.90/10.90 2.63/3.11 45/43/41 | 58 1020x400x534

B42AHYN781 13.0/13.5 2.89/3.46 47/45/42 | 56 1320x400x534

Sound Pressure(dB(A)±3)Indoor(H/M/L) | Outdoor(H)

Capacity(kW)Cooling / Heating

EER/COP(W/W)Cooling / Heating

FIXEDSPEED

Dimension(mm)Model

Air flow rateat 2mmAq

Air flow rateat 10mmAq

External static pressure(mmAq)

Air volume can be optimised to reduce noise and comply with the system design utilising E.S.Ptechnology. This enables you to optimise duct work installation, by maintaining capacities andsound levels as required.

* Available in LBNH1863BL, B24AHF-NH5, B62UWYN881, B72UWYN881

E.S.P: External Static Pressure

9www.lge.com.au8 www.lge.com.au

Page 7: Ducted Split System - Inverter, Split and ... - Oregan Air new Ducted System line up incorporates ... An inverter compressor will vary its capacity in order to ... Ducted Split System

Specifications

Cooling (Min/Rated/Max) (kW)

Heating (Min/Rated/Max) (kW)

Voltage.Frequency/Phase (V.Hz /ø)

Power Consumption Cooling (kW)

(Min/Rated/Max) Heating (kW)

Running Current. Cooling (A)

(Rated) Heating (A)

EER Cooling (W/W)

COP Heating (W/W)

Static Pressure (External) (Pa)

Air Volume Indoor(H/M/L) (l /sec)

Outdoor (l /sec)

Moisture Removal (l /hr)

Noise Level Cooling Indoor(H/M/L) (1.5m)

(Sound Pressure) Outdoor (1.0m)

Heating Indoor(H/M/L) (1.5m)

Outdoor (1.0m)

Refrigerant Type (g)

Operating range Cooling °C

(outdoor) Heating °C

Net Dimensions Indoor WxHxD (mm)

Outdoor WxHxD (mm)

Net Weight Indoor/Outdoor (Kg)

Service Valve Liquid (mm)

Gas (mm)

Drain Connection Pipe Out diameter (mm)

Supply air spigot width x height (mm)

Return air spigot width x height (mm)

Pre-refrigerant charge (m)

Max. Elevation Outdoor~Indoor (m)

Max. InterunitPiping Length Outdoor~Indoor (m)

Feature

Durable Coating

Weekly Program

Child Lock Function

Two Thermistor Control

Evaporate safety tray

Auto Restart

Long Distance(50m)/High Elevation(30m)

LCD Deluxe Wall Controller_PDRCUDB0

Standard Wall Controller_PQRCUSA0

RF Controller_PQRFA0

Zone Control

Dual Wall Control

Group Control

Central Controller

Drain Pump

B30AWYN661

B30AWYUE61

• Notes:Design and specifications are subject to change without prior notice for product improvement.• Cooling Capacities are based on an indoor air temp 27ºC DB 19ºC WB and outdoor air temp. 35ºC DB and 24ºC WB in accordance with AS3823.1.2.

Model Indoor

Outdoor

3.20~8.00~9.6

3.65~9.20~11.0

220~240 , 50/1

1.22~3.05~3.66

1.12~2.80~3.36

13.5

12.5

2.62

3.29

130

533 / 433 / 333

967 x 1

1.8

44 / 41 / 39

51

44 / 41 / 39

53

R410A (2100)

-10~46

-10~24

1020 x 400 x 534

870 x 800 x 320

42 / 56

6.35

15.88

25.4

840 x 287

882 x 315

15

30

50

•••••••

Option

Option

Option

Option

Option

Option

Option

Option

B36AWYN661

B36AWYUE61

4.10~9.90~11.85

4.40~11.00~12.10

220~240 , 50/1

1.44~3.65~4.14

1.44~3.60~3.96

16.0

16.0

2.71

3.06

130

633 / 533 / 433

533 x 2

3.0

45 / 43 / 41

53

45 / 43 / 41

56

R410A (2600)

-10~46

-10~24

1020 x 400 x 534

870 x 1060 x 320

43 / 80

6.35

15.88

25.4

840 x 287

882 x 315

15

30

50

•••••••

Option

Option

Option

Option

Option

Option

Option

Option

B42AWYN661

B42AWYU361

4.92~12.3~14.1

5.64~14.1~15.5

220~240 , 50/1

1.81~4.52~5.42

1.88~4.70~5.64

20.0

21.0

2.72

3.00

130

766 / 633 / 500

1000 x 2

4.0

47 / 45 / 42

54

47 / 45 / 42

55

R410A (3100)

-10~46

-10~24

1020 x 400 x 534

950 x 1380 x 330

43 / 105

9.52

15.88

25.4

840 x 287

882 x 315

15

30

50

•••••••

Option

Option

Option

Option

Option

Option

Option

Option

Ducted

Outdoor Unit

11www.lge.com.au10 www.lge.com.au

L G A I R C O N D I T I O N E R S

12.3kW9.9kW8.00kW

Cooling (Min/Rated/Max) (kW)

Heating (Min/Rated/Max) (kW)

Voltage.Frequency/Phase (V.Hz /ø)

Power Consumption Cooling (kW)

(Min/Rated/Max) Heating (kW)

Running Current. Cooling (A)

(Rated) Heating (A)

EER Cooling (W/W)

COP Heating (W/W)

Static Pressure (External) (Pa)

Air Volume Indoor(H/M/L) (l /sec)

Outdoor (l /sec)

Moisture Removal (l /hr)

Noise Level Cooling Indoor(H/M/L) (1.5m)

(Sound Pressure) Outdoor (1.0m)

Heating Indoor(H/M/L) (1.5m)

Outdoor (1.0m)

Refrigerant Type (g)

Operating range Cooling °C

(outdoor) Heating °C

Net Dimensions Indoor WxHxD (mm)

Outdoor WxHxD (mm)

Net Weight Indoor/Outdoor (Kg)

Service Valve Liquid (mm)

Gas (mm)

Drain Connection Pipe Out diameter (mm)

Supply air spigot width x height (mm)

Return air spigot width x height (mm)

Pre-refrigerant charge (m)

Max. Elevation Outdoor~Indoor (m)

Max. InterunitPiping Length Outdoor~Indoor (m)

Feature

Durable Coating

Weekly Program

Child Lock Function

Two Thermistor Control

Evaporate safety tray

Auto Restart

Long Distance(50m)/High Elevation(30m)

Ez Tuning

LCD Deluxe Wall Controller_PDRCUDB0

Standard Wall Controller_PQRCUSA0

RF Controller_PQRFA0

Zone Control

Dual Wall Control

Group Control

Central Controller

Drain Pump

B48AWYN761

B48AWYU361

• Notes:Design and specifications are subject to change without prior notice for product improvement.• Cooling Capacities are based on an indoor air temp 27®¨C DB 19®¨C WB and outdoor air temp. 35®¨C DB and 24®¨C WB in accordance with AS3823.1.2.

Model Indoor

Outdoor

5.64~14.1~16.2

6.32~15.8~17.4

220~240 , 50/1

2.00~5.00~5.75

1.88~4.70~5.17

21.8

20.6

2.82

3.36

130

1000/833/667

1000x2

4.1

51 / 48 / 45

55

51 / 48 / 45

57

R410A (3750)

-10~46

-10~24

1320 x 400 x 534

950 x 1380 x 330

53 / 105

9.52

19.05

25.4

840 x 287

1182 x 315

15

30

50

•••••••-

Option

Option

Option

Option

Option

Option

Option

Option

B62UWYN881

B62UWYUY81

10.8~18.0~20.0

12.0~21.0~22.4

380~415 , 50/3

3.20~6.10~7.10

3.80~7.20~7.80

10.4

12.0

2.95

2.92

150

1000/917/833

1583

5.14

50/49/47

57

50/49/47

57

R410A (6700)

-10~46

-10~24

1562 x 460 x 688

806 x 1555 x 730

90 / 150

9.52

19.05

25.4

1120 x 290

1396 x 391

15

30

50

••••-

•••

Option

Option

Option

Option

Option

Option

Option

Option

B55AWYN761

B55AWYU361

6.4~16.0~17.6

7.04~17.6~19.4

220~240 , 50/1

2.34~5.58~6.44

2.16~5.40~5.95

25.4

23.5

2.74

3.26

130

1000/833/667

1000x2

4.5

51/48/45

55

51/48/45

57

R410A (3750)

-10~46

-10~24

1320 x 400 x 534

950 x 1380 x 330

53 / 105

9.52

19.05

25.4

840 x 287

1182 x 315

15

30

50

•••••••-

Option

Option

Option

Option

Option

Option

Option

Option

B72UWYN881

B72UWYUW81

12.6~21.0~23.5

14.1~23.5~26.3

380~415 , 50/3

3.50~6.56~7.60

4.00~7.50~9.20

11.0

12.3

3.20

3.13

180

1167/1083/1000

3000

5.9

52/50/49

59

52/50/49

59

R410A (8500)

-10~46

-10~24

1562 x 460 x 688

1280 x 1555 x 730

90 / 250

9.52

22.2

25.4

1120 x 290

1396 x 391

15

30

50

••••-•••

Option

Option

Option

Option

Option

Option

Option

Option

Ducted

Outdoor Unit

18.0kW 21.0kW14.1~16.0kW

Page 8: Ducted Split System - Inverter, Split and ... - Oregan Air new Ducted System line up incorporates ... An inverter compressor will vary its capacity in order to ... Ducted Split System

Item Model name Image Function Application

• Schedule Control• History Function• Zone Control

• Lock Function• Auto Changeover• Temperature Limit Function

5.3kW~21kW

8kW~21kW(not applied to 5/7kW)

8.0kW~16kW / 18kW / 21kW*Refer to each model PDB forapplicable models

5.3kW~21kW

• ABDPG : 5.28/6.87/18.0/21.0kW• ABDP7 : 8.0kW ~ 16.0kW*Refer to each model PDB forapplicable models

Control Options

PQCSW320A0EAC Smart

• 256 indoor units• Control / Monitoring• Schedule management• Lock function

• History function• Peak control• PDI monitoring

PQCPA11A0E(Without IO)

PQCPB11A0E(With IO)

ACP

• 4,096 indoor units(16 ACP)• Control / Monitoring• Schedule management• Lock function• Temperature range restriction• Temperature limit function

• Auto Changeover function• History function• Peak control• PDI monitoring• Interlocking function• Printing function

PQCSS520A0EAC Manager

• Operating mode• Touch screen / LCD back_light• Room temp• E.S.P function

• Fan / Plasma / Swirl / Heater• Vane control / Auto swing • Reservation• Timer function• Child lock

• Operating mode• 24 Hour On/Off time in 1 hour

intervals• Room temp• 3-Step Fan Speed selection

• Vane control / Auto swing • Reservation• Timer function• 2 Controllers can be connected

to 1 indoor unit

PDRCUDB0Deluxe Wall Controller

PQRCUSA0Standard Wall Controller

ABDPG

ABDP7

• Controls different zones (up to 4 zones)

Electronic Accessory

PBDC40Damper Controller

• In some places where natural drainage is not possible The drainpump is very useful to pump out condensed water from indoorunit.

• Drain pump assembly(AC 220_240V, 50/60Hz)

Mechanical Accessory

ABDPG

ABDP7

Drain PumpKit

Accessory

• It can help to detect the exact room temperature at the optimalposition.

• Extension cable (15m)

PQRSTA0Remote Temperature Sensor

• Extended cable for wallcontroller

• extension cable assembly: 2EA• length: 10m

Wires

PZCWRC1Extension cable

Specifications

Outdoor Unit

12 www.lge.com.au

13.0kW9.9kW8.28kW6.87kW5.28kW

13www.lge.com.au

Item Model name Image Function Application

Item Model name Image Function Application

Item Model name Image Function Application

Cooling (kW)

Heating (kW)

Voltage.Frequency/Phase (V.Hz /ø)

Power Consumption Cooling (kW)

(Min/Rated/Max) Heating (kW)

Running Current. Cooling (A)

(Rated) Heating (A)

EER Cooling (W/W)

COP Heating (W/W)

Static Pressure (External) (Pa)

Air Volume Indoor(H/M/L) (l /sec)

Outdoor (l /sec)

Moisture Removal (l /hr)

Noise Level Cooling Indoor(H/M/L) (1.5m)

(Sound Pressure) Outdoor (1.0m)

Heating Indoor(H/M/L) (1.5m)

Outdoor (1.0m)

Refrigerant Type (g)

Operating range Cooling °C

(outdoor) Heating °C

Net Dimensions Indoor WxHxD (mm)

Outdoor WxHxD (mm)

Net Weight Indoor/Outdoor (Kg)

Service Valve Liquid (mm)

Gas (mm)

Drain Connection Pipe Out diameter (mm)

Supply air spigot width x height (mm)

Return air spigot width x height (mm)

Pre-refrigerant charge (m)

Max. Elevation Outdoor~Indoor (m)

Max. InterunitPiping Length Outdoor~Indoor (m)

Feature

Durable Coating

Weekly Program

Child Lock Function

Two Thermistor Control

Evaporate safety tray

Auto Restart

Long Distance(50m)/High Elevation(30m)

Ez Tuning

LCD Deluxe Wall Controller_PDRCUDB0

Standard Wall Controller_PDRCUSZ0

RF Controller_PQRFA0

Zone Control

Dual Wall Control

Group Control

Central Controller

Drain Pump

LBNH1863BL

LBUH1863BL

• Notes:Design and specifications are subject to change without prior notice for product improvement.• Cooling Capacities are based on an indoor air temp 27ºC DB 19ºC WB and outdoor air temp. 35ºC DB and 24ºC WB in accordance with AS3823.1.2.

Model Indoor

Outdoor

5.28

5.28

220~240 , 50/1

2.10

1.88

10.0

9.5

2.51

2.80

80

275 / 242 217

816

2.1

38 / 36 / 34

55

38 / 36 / 34

55

R22 (1300)

21~43

-5~24

880 x 260 x 450

870 x 655 x 320

34 / 52

6.35

15.88

25.4

750 x 160

748 x 168

7.5

30

50

••••-•••

Option

Option

Option

-

-

Option

Option

Option

B24AHF-NH5

B24AHF-UE5

6.87

7.50

220~240 , 50/1

3.60

2.70

11.0

12.0

2.64

2.77

80

300 / 275 / 233

967

2.57

42 / 40 / 38

51

42 / 40 / 38

52

R410A (2050)

21~43

-5~24

880 x 260 x 450

870 x 800 x 320

42 / 80

6.35

15.88

25.4

750 x 160

748 x 168

7.5

30

50

••••-•••

Option

Option

Option

-

-

Option

Option

Option

B30AHYN661

B30AHYUE61

8.28

8.40

220~240 , 50/1

3.15

2.85

13.5

12.5

2.63

2.95

130

533 / 433 / 333

533 x 2

2.06

44 / 41 / 39

53

44 / 41 / 39

54

R410A (2300)

21~46

-5~24

1020 x 400 x 534

870 x 1060 x 320

43 / 80

6.35

15.88

25.4

840 x 287

882 x 315

15

30

50

•••••••-

Option

Option

Option

Option

Option

Option

Option

Option

B36AHYN661

B36AHYUH61

9.90

10.90

220~240 , 50/1

3.76

3.50

17.0

15.5

2.63

3.11

130

633 / 533 / 433

883 x 2

2.14

45 / 43 / 41

55

45 / 43 / 41

58

R410A (2600)

21~46

-5~24

1020 x 400 x 534

900 x 1165 x 370

43 / 98

6.35

15.88

25.4

840 x 287

882 x 315

15

30

50

•••••••-

Option

Option

Option

Option

Option

Option

Option

Option

B42AHYN781

B42AHYU381

13.0

13.5

380~415 , 50/3

4.5

3.9

7.4

6.4

2.89

3.46

130

813 / 670 / 529

1000*2

2.63

47 / 45 / 42

53

47 / 45 / 42

56

R410A (3600)

21-46

-5-24

1320 x 400 x 534

950 x 1380 x 330

53 / 108

9.52

19.05

25.4

840 x 287

1182 x 315

15

30

50

•••••••-

Option

Option

Option

Option

Option

Option

Option

Option

Ducted